Attachment ISAT Fixed-TF Supple

ISAT Fixed-TF Supple

LETTER submitted by ISAT US Inc.

Letter

2015-08-14

This document pretains to SES-LIC-20150625-00383 for License on a Satellite Earth Station filing.

IBFS_SESLIC2015062500383_1099624

                                                                                 1100 Connecticut Ave NW
                                                                                 Suite 1200
                                                                                 Washington DC 20036
                                                                                 USA

                                                                                 T +1 202 248 5100
                                                                                 W inmarsat.com
August 14, 2015


VIA ELECTRONIC FILING IN IBFS


Ms. Marlene H. Dortch
Secretary
Federal Communications Commission
445 12th Street, SW
Washington, DC 20554


               Re:    ISAT US, Inc., Supplemental Submission; File No. SES-LIC-20150625-
                      00383, Call Sign E150097

Dear Ms. Dortch:

        ISAT US, Inc. (“ISAT US”) supplements the above-referenced application for a blanket
license to operate fixed and temporary-fixed terminals with the following additional and corrected
information.

       24-Hour Point of Contact

        Attached hereto is Exhibit G, which identifies the 24-hour point of contact with the ability
to shut down any of the proposed terminals immediately upon notification of harmful interference.

       Corrected Antenna Diameter

       Each of the antennas identified for Site 7 in the associated Form 312, Item E32 (antenna
models Connect 100, Connect 100T and SKY98GX/01) has a diameter equivalent to 0.934 meters.
The minor and major diameters of these elliptical antennas are correctly identified in the form as
0.877 meters and 0.97041 meters, respectively.

       Amended Radiation Hazard Analysis

       Attached hereto is an Amended Exhibit C Radiation Hazard Analysis. The calculations in
the exhibit have been revised to reflect the antenna gain level and frequency as provided in the
Form 312 Schedule B.


       If you have any questions regarding this submission, please feel free to contact the
undersigned.



                                             Respectfully submitted,

                                               /s/

                                             Giselle Creeser


Attachments

cc:    Paul Blais
       Trang Nguyen


                                           ISAT US Inc.
                                          FCC Form 312
                                       AMENDED Exhibit C
                                     Radiation Hazard Analysis

1.0 Introduction

This Exhibit analyzes the non-ionizing radiation levels for the earth stations included in this
application. The analysis and calculations performed in this Exhibit comply with the methods
described in the FCC Office of Engineering and Technology Bulletin, No. 65 first published in 1985
and revised in 1997 in Edition 97-01.

Bulletin No. 65 and the FCC R&O 96-326 specifies two Maximum Permissible Exposure (MPE)
limits that are dependent on the situation in which the exposure takes place and/or the status of the
individuals who are subject to the exposure. These are described below:

• General Population/Uncontrolled environment MPE limit is 1 mW/cm2. The General Population /
Uncontrolled MPE is a function of transmit frequency and is for an exposure period of thirty minutes
or less.

• Occupational/Controlled environment MPE limit is 5 mW/cm2. The Occupational MPE is a function
of transmit frequency and is for an exposure period of six minutes or less.

The analysis determined the power flux density levels of the earth station in the 1) far-field, 2) near-
field, 3) transition region, 4) region between the feed and main reflector surface, 5) at the main
reflector surface, and 6) between the antenna edge and the ground. The summary of results and
discussion is provided in Section 2 and the detailed analyses are provided in Section 3.

Section 2.0 – Summary of Results

The terminals proposed in this application are for professional use and not for use by the general
public. The analysis of the non-ionizing radiation levels provided in Section 3 assumed the maximum
allowed input power to antenna of 5W and a 100% duty cycle resulting in worst case radiation levels.
In a significant number of deployments the terminals duty cycle would be below 100% and the actual
power required would be lower than the 5W maximum resulting in lower radiation levels than those
calculated. As with any directional antenna the maximum level of non-ionizing radiation is in the
main beam of the antenna that is pointed to the satellite. As one moves around the antenna to the side
lobes and back lobes the radiation levels decrease significantly. So the maximum radiation level from
an antenna occurs in a limited area in the direction the antenna is pointed to. The terminals proposed
in this application are designed not to transmit if the receive signal from the satellite is blocked, which
could be caused by a person standing in front of the terminal or from other blockage. If the receive
signal is blocked the transmitter is shut down and will not resume operating until the signal from the
satellite is reacquired. This operational feature of the terminal minimizes the potential for human
radiation exposure. The terminals will be turned off prior to any maintenance being conducted when a
person may need to be in close proximity to the feed flange and main reflector.

The Tables below summarize the result for each antenna terminal type. As shown all but the two
smaller antenna terminals meet the controlled environment limit of ≤ 5 mW/cm2 except at the feed
flange. For the two smaller antennas the level is also exceeded at the main reflector. In a controlled
environment technicians are trained and procedures are put in place to ensure that a safe distance is
maintained from the antenna while in operation. These procedures can include fencing around the
terminal, limits on the operation of the terminal, warning signs and other means of alerting workers,
as appropriate, for the specific deployment scenario.


The terminals when operating with maximum input power and a 100% duty cycle vary in meeting the
uncontrolled environment limit of ≤ 1 mW/cm2. For the 1.8 m antenna the limit is met except at the
feed flange, however for most of the other antennas the level is exceeded except in the far field. As
described above the maximum radiation levels occur in a limited area in the direction the antenna is
pointed to and the automatic shut off capability of the terminal when the satellite receive signal is
blocked will reduce potential human exposure. In addition these terminals are for professional use so
the operators will be trained in how to operate the terminal safely. Furthermore the manuals for these
terminals will explicitly indicate that precautions, such has not standing in front of the terminal, are
required to limit potential exposure. The terminals will also clearly be marked to ensure that the
terminal operator and the general public are aware of the potential radiation exposure and the need to
avoid physical proximity to the terminal. It is noted that the highest radiation levels are at the feed
flange and main reflector. The feed flange is a very small area of the terminal antenna and it is
extremely unlikely that a person would be near the feed flange or the main reflector while the terminal
is in operation.

 Cobham 3075 & 5075
                                                         Limit               Limit
                                   Calculated         Controlled
                     Distance                                            Uncontrolled
 Region                          Power Density       Environment
                       (m)                                               Environment
                                  (mW/cm2)           ≤ 5 mW/cm2          ≤ 1 mW/cm2
 Near Field            13.9            2.2            Meets Limit       Exceeds Limit
 Far Field             33.5            0.9            Meets Limit        Meets Limit
 Transition                                           Meets Limit
                                       2.2                              Exceeds Limit
 Region                13.9
 Feed Flange           NA            1370.9          Exceeds Limit      Exceeds Limit
 Main Reflector        NA             4.5             Meets Limit       Exceeds Limit

 Cobham 7100
                                                         Limit               Limit
                                   Calculated         Controlled
                     Distance                                            Uncontrolled
 Region                          Power Density       Environment
                       (m)                                               Environment
                                  (mW/cm2)           ≤ 5 mW/cm2          ≤ 1 mW/cm2
 Near Field            24.8            1.6            Meets Limit       Exceeds Limit
 Far Field             59.5            0.7            Meets Limit        Meets Limit
 Transition                                           Meets Limit
                                       1.6                              Exceeds Limit
 Region                24.8
 Feed Flange           NA             698.0          Exceeds Limit      Exceeds Limit
 Main Reflector        NA              2.5            Meets Limit       Exceeds Limit

 L3 GCS Chettah II
                                                         Limit               Limit
                                   Calculated         Controlled
                     Distance                                            Uncontrolled
 Region                          Power Density       Environmen
                       (m)                                               Environment
                                  (mW/cm2)           ≤ 5 mW/cm2          ≤ 1 mW/cm2
 Near Field            17.9            2.5            Meets Limit       Exceeds Limit
 Far Field             43.0            1.1            Meets Limit       Exceeds Limit
 Transition                                           Meets Limit
                                       2.5                              Exceeds Limit
 Region                17.9


Feed Flange          NA         873.3       Exceeds Limit   Exceeds Limit
Main Reflector       NA          3.5         Meets Limit    Exceeds Limit

L3 GCS Hawkeye III
                                                Limit           Limit
                              Calculated     Controlled
                 Distance                                   Uncontrolled
Region                      Power Density   Environment
                   (m)                                      Environment
                             (mW/cm2)       ≤ 5 mW/cm2      ≤ 1 mW/cm2
Near Field         35.7          1.1        Meets Limit     Exceeds Limit
Far Field          85.7          0.5        Meets Limit      Meets Limit
Transition                                  Meets Limit
                                 1.1                        Exceeds Limit
Region             35.7
Feed Flange        NA           873.3       Exceeds Limit   Exceeds Limit
Main Reflector     NA            1.8         Meets Limit    Exceeds Limit

Paradigm/SWT Connect70
                                                Limit           Limit
                              Calculated     Controlled
                 Distance                                   Uncontrolled
Region                      Power Density   Environment
                   (m)                                      Environment
                             (mW/cm2)       ≤ 5 mW/cm2      ≤ 1 mW/cm2
Near Field         11.8          3.5        Meets Limit     Exceeds Limit
Far Field          28.3          1.5        Meets Limit     Exceeds Limit
Transition                                  Meets Limit
                                 3.5                        Exceeds Limit
Region             11.8
Feed Flange        NA           679.9       Exceeds Limit   Exceeds Limit
Main Reflector     NA            5.3        Exceeds Limit   Exceeds Limit

SWT ATOM 65/GX/01 ATOM 65AAGX/01
                                                Limit           Limit
                              Calculated     Controlled
                 Distance                                   Uncontrolled
Region                      Power Density   Environment
                   (m)                                      Environment
                             (mW/cm2)       ≤ 5 mW/cm2      ≤ 1 mW/cm2
Near Field         10.5          2.8        Meets Limit     Exceeds Limit
Far Field          25.1          1.2        Meets Limit     Exceeds Limit
Transition                                  Meets Limit
                                 2.8                        Exceeds Limit
Region             10.5
Feed Flange        NA          1471.5       Exceeds Limit   Exceeds Limit
Main Reflector     NA           6.0         Exceeds Limit   Exceeds Limit

Paradigm/SWT Connect 100, 100T, Sky 98
                                                Limit           Limit
                              Calculated     Controlled
                 Distance                                   Uncontrolled
Region                      Power Density   Environment
                   (m)                                      Environment
                             (mW/cm2)       ≤ 5 mW/cm2      ≤ 1 mW/cm2
Near Field         21.6          1.5        Meets Limit     Exceeds Limit
Far Field          51.9          0.7        Meets Limit      Meets Limit
Transition         21.6          1.5        Meets Limit     Exceeds Limit


Region
Feed Flange        NA           679.9       Exceeds Limit   Exceeds Limit
Main Reflector     NA            2.9         Meets Limit    Exceeds Limit

Paradigm/SWT Connect 180, Sky 180GX/01
                                                Limit           Limit
                              Calculated     Controlled
                 Distance                                   Uncontrolled
Region                      Power Density   Environment
                   (m)                                      Environment
                             (mW/cm2)       ≤ 5 mW/cm2      ≤ 1 mW/cm2
Near Field        80.3           0.4        Meets Limit     Meets Limit
Far Field         192.8          0.2        Meets Limit     Meets Limit
Transition                                  Meets Limit     Meets Limit
                                 0.4
Region             80.3
Feed Flange        NA          1327.4       Exceeds Limit   Exceeds Limit
Main Reflector     NA           0.8          Meets Limit     Meets Limit


Section 3.0 – Detailed calculations

3.1 Cobham 3075/5075

"Input Parameters" Table from page 51
Input Parameter                                   Value        Units    Symbol
Antenna Diameter                                  0.75         m        D
Antenna Transmit Gain                             44.2         dBi      G
Transmit Frequency                                29750        MHz      f
Antenna Feed Flange Diameter                      4.31         cm       d
Power Input to the Antenna                        5            Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                              Value        Units    Symbol   Formula
Antenna Surface Area                              0.4418       m²       A        πD²/4
Area of Antenna Flange                            14.5892      cm²      a        πd²/4
Antenna Efficiency                                0.4818       real     η        gλ²/(π²D²)
Gain Factor                                       26302.6799   real     g        10^(G/10)
Wavelength                                        0.0101       m        λ        300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                              Value        Units    Symbol   Formula
Near-Field Distance                               13.9453125   m        Rnf      D²/(4λ)
Distance to Far-Field                             33.46875     m        Rff      0.6D²/λ
Distance of Transition Range                      13.9453125   m        Rt       Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                              Value        Units    Symbol   Formula
Power Density in the Near Field                   2.1812       mW/cm²   Snf      16ηP/(πD²)
Power Density in the Far Field                    0.9343       mW/cm²   Sff      gP/(4πRff²)
Power Density in the Transition Region            2.1812       mW/cm²   St       Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                              Value        Units    Symbol   Formula
Power Density at the Feed Flange                  1370.8767    mW/cm²   Sfa      4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                              Value        Units    Symbol Formula
Power Density at Main Reflector                   4.5272       mW/cm²   Ssurface 4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                              Value        Units    Symbol   Formula
Power Density between Reflector and Ground        1.1318       mW/cm²   Sg       P/A


3.2 Cobham 7100

"Input Parameters" Table from page 51
Input Parameter                                  Value        Units    Symbol
Antenna Diameter                                 1            m        D
Antenna Transmit Gain                            47.9         dBi      G
Transmit Frequency                               29750        MHz      f
Antenna Feed Flange Diameter                     6.04         cm       d
Power Input to the Antenna                       5            Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                             Value        Units    Symbol   Formula
Antenna Surface Area                             0.7854       m²       A        πD²/4
Area of Antenna Flange                           28.6517      cm²      a        πd²/4
Antenna Efficiency                               0.6353       real     η        gλ²/(π²D²)
Gain Factor                                      61659.5002   real     g        10^(G/10)
Wavelength                                       0.0101       m        λ        300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                             Value        Units    Symbol   Formula
Near-Field Distance                              24.8         m        Rnf      D²/(4λ)
Distance to Far-Field                            59.5         m        Rff      0.6D²/λ
Distance of Transition Range                     24.8         m        Rt       Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                             Value        Units    Symbol   Formula
Power Density in the Near Field                  1.6179       mW/cm²   Snf      16ηP/(πD²)
Power Density in the Far Field                   0.6930       mW/cm²   Sff      gP/(4πRff²)
Power Density in the Transition Region           1.6179       mW/cm²   St       Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                             Value        Units    Symbol   Formula
Power Density at the Feed Flange                 698.0380     mW/cm²   Sfa      4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                            Value         Units    Symbol Formula
Power Density at Main Reflector                 2.5466        mW/cm²   Ssurface 4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                            Value         Units    Symbol   Formula
Power Density between Reflector and Ground      0.6366        mW/cm²   Sg       P/A


3.3 L3 Cheetah II

"Input Parameters" Table from page 51
Input Parameter                              Value         Units    Symbol
Antenna Diameter                             0.85          m        D
Antenna Transmit Gain                        46.9          dBi      G
Transmit Frequency                           29750         MHz      f
Antenna Feed Flange Diameter                 5.4           cm       d
Power Input to the Antenna                   5             Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                         Value         Units    Symbol     Formula
Antenna Surface Area                         0.5674        m²       A          πD²/4
Area of Antenna Flange                       22.9015       cm²      a          πd²/4
Antenna Efficiency                           0.6985        real     η          gλ²/(π²D²)
Gain Factor                                  48977.8819    real     g          10^(G/10)
Wavelength                                   0.0101        m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                         Value         Units    Symbol     Formula
Near-Field Distance                          17.91197917   m        Rnf        D²/(4λ)
Distance to Far-Field                        42.98875      m        Rff        0.6D²/λ
Distance of Transition Range                 17.91197917   m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                         Value         Units    Symbol     Formula
Power Density in the Near Field              2.4619        mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field               1.0545        mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region       2.4619        mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                         Value         Units    Symbol     Formula
Power Density at the Feed Flange             873.3039      mW/cm²   Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                        Value          Units    Symbol     Formula
Power Density at Main Reflector             3.5246         mW/cm²   Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                        Value          Units    Symbol     Formula
Power Density between Reflector and
Ground                                      0.8812         mW/cm²   Sg         P/A


3.4 L3 Hawkeye III

"Input Parameters" Table from page 51
Input Parameter                                  Value        Units    Symbol
Antenna Diameter                                 1.2          m        D
Antenna Transmit Gain                            49.4         dBi      G
Transmit Frequency                               29750        MHz      f
Antenna Feed Flange Diameter                     5.4          cm       d
Power Input to the Antenna                       5            Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                             Value        Units    Symbol     Formula
Antenna Surface Area                             1.1309       m²       A          πD²/4
Area of Antenna Flange                           22.9015      cm²      a          πd²/4
Antenna Efficiency                               0.6232       real     η          gλ²/(π²D²)
Gain Factor                                      87096.3590   real     g          10^(G/10)
Wavelength                                       0.0101       m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                             Value        Units    Symbol     Formula
Near-Field Distance                              35.7         m        Rnf        D²/(4λ)
Distance to Far-Field                            85.68        m        Rff        0.6D²/λ
Distance of Transition Range                     35.7         m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                             Value        Units    Symbol     Formula
Power Density in the Near Field                  1.1021       mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field                   0.4721       mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region           1.1021       mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                             Value        Units    Symbol     Formula
Power Density at the Feed Flange                 873.3039     mW/cm²   Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                            Value         Units    Symbol     Formula
Power Density at Main Reflector                 1.7684        mW/cm²   Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                            Value         Units    Symbol     Formula
Power Density between Reflector and Ground 0.4421             mW/cm²   Sg         P/A


3.5 Paradigm/SWT Connect 70

"Input Parameters" Table from page 51
Input Parameter                                  Value        Units    Symbol
Antenna Diameter                                 0.69         m        D
Antenna Transmit Gain                            44.8         dBi      G
Transmit Frequency                               29750        MHz      f
Antenna Feed Flange Diameter                     6.12         cm       d
Power Input to the Antenna                       5            Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                             Value        Units    Symbol     Formula
Antenna Surface Area                             0.3739       m²       A          πD²/4
Area of Antenna Flange                           29.4157      cm²      a          πd²/4
Antenna Efficiency                               0.6536       real     η          gλ²/(π²D²)
Gain Factor                                      30199.5172   real     g          10^(G/10)
Wavelength                                       0.0101       m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                             Value        Units    Symbol     Formula
Near-Field Distance                              11.8033125   m        Rnf        D²/(4λ)
Distance to Far-Field                            28.32795     m        Rff        0.6D²/λ
Distance of Transition Range                     11.8033125   m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                             Value        Units    Symbol     Formula
Power Density in the Near Field                  3.4958       mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field                   1.4974       mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region           3.4958       mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                             Value        Units    Symbol     Formula
Power Density at the Feed Flange                 679.9079     mW/cm²   Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                           Value          Units    Symbol     Formula
Power Density at Main Reflector                5.3488         mW/cm²   Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                           Value          Units    Symbol     Formula
Power Density between Reflector and Ground 1.3372             mW/cm²   Sg         P/A


3.6 SWT ATOM 65/GX/01 ATOM 65AAGX/01

"Input Parameters" Table from page 51
Input Parameter                              Value          Units    Symbol
Antenna Diameter                             0.65           m        D
Antenna Transmit Gain                        42.8           dBi      G
Transmit Frequency                           29750          MHz      f
Antenna Feed Flange Diameter                 4.16           cm       d
Power Input to the Antenna                   5              Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                         Value          Units    Symbol     Formula
Antenna Surface Area                         0.3318         m²       A          πD²/4
Area of Antenna Flange                       13.5914        cm²      a          πd²/4
Antenna Efficiency                           0.4647         real     η          gλ²/(π²D²)
Gain Factor                                  19054.6072     real     g          10^(G/10)
Wavelength                                   0.0101         m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                          Value         Units    Symbol     Formula
Near-Field Distance                           10.47447917   m        Rnf        D²/(4λ)
Distance to Far-Field                         25.13875      m        Rff        0.6D²/λ
Distance of Transition Range                  10.47447917   m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                         Value          Units    Symbol     Formula
Power Density in the Near Field              2.8009         mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field               1.1997         mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region       2.8009         mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                         Value          Units    Symbol     Formula
Power Density at the Feed Flange             1471.5203      mW/cm²   Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                        Value           Units    Symbol     Formula
Power Density at Main Reflector             6.0273          mW/cm²   Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                        Value           Units    Symbol     Formula
Power Density between Reflector and
Ground                                      1.5068          mW/cm²   Sg         P/A


3.7 Paradigm/SWT Connect 100, 100T, Sky 98

"Input Parameters" Table from page 51
Input Parameter                              Value          Units    Symbol
Antenna Diameter                             0.934          m        D
Antenna Transmit Gain                        46.5           dBi      G
Transmit Frequency                           29750          MHz      f
Antenna Feed Flange Diameter                 6.12           cm       d
Power Input to the Antenna                   5              Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                         Value          Units    Symbol     Formula
Antenna Surface Area                         0.6851         m²       A          πD²/4
Area of Antenna Flange                       29.4157        cm²      a          πd²/4
Antenna Efficiency                           0.5276         real     η          gλ²/(π²D²)
Gain Factor                                  44668.3592     real     g          10^(G/10)
Wavelength                                   0.0101         m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                          Value         Units    Symbol     Formula
Near-Field Distance                           21.62715917   m        Rnf        D²/(4λ)
Distance to Far-Field                         51.905182     m        Rff        0.6D²/λ
Distance of Transition Range                  21.62715917   m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                         Value          Units    Symbol     Formula
Power Density in the Near Field              1.5401         mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field               0.6597         mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region       1.5401         mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                         Value          Units    Symbol     Formula
Power Density at the Feed Flange             679.9079       mW/cm²   Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                        Value           Units    Symbol     Formula
Power Density at Main Reflector             2.9192          mW/cm²   Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                        Value           Units    Symbol     Formula
Power Density between Reflector and
Ground                                      0.7298          mW/cm²   Sg         P/A


3.8 Paradigm/SWT Connect 180, Sky 180

"Input Parameters" Table from page 51
Input Parameter                                   Value         Units    Symbol
Antenna Diameter                                  1.8           m        D
Antenna Transmit Gain                             52.4          dBi      G
Transmit Frequency                                29750         MHz      f
Antenna Feed Flange Diameter                      4.38          cm       d
Power Input to the Antenna                        5             Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                              Value         Units    Symbol     Formula
Antenna Surface Area                              2.5446        m²       A          πD²/4
Area of Antenna Flange                            15.0669       cm²      a          πd²/4
Antenna Efficiency                                0.5526        real     η          gλ²/(π²D²)
Gain Factor                                       173780.0829   real     g          10^(G/10)
Wavelength                                        0.0101        m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                              Value         Units    Symbol     Formula
Near-Field Distance                               80.325        m        Rnf        D²/(4λ)
Distance to Far-Field                             192.78        m        Rff        0.6D²/λ
Distance of Transition Range                      80.325        m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                              Value         Units    Symbol     Formula
Power Density in the Near Field                   0.4344        mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field                    0.1861        mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region            0.4344        mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                              Value         Units    Symbol     Formula
Power Density at the Feed Flange                  1327.4088     mW/cm²   Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                              Value         Units    Symbol     Formula
Power Density at Main Reflector                   0.7860        mW/cm²   Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                              Value         Units    Symbol     Formula
Power Density between Reflector and Ground        0.1965        mW/cm²   Sg         P/A


                                         ISAT US Inc.
                                        FCC Form 312
                                           Exhibit G

                                  24-Hour Point of Contact


       The 24-hour point of contact with the ability to shut down any of the terminals
immediately upon notification of harmful interference is at Inmarsat’s Lino Lakes Gateway, call
sign E120072:

       Kevin Baker
       6211 Glen Circle
       Lino Lakes, MN 55014
       Tel: (808) 469-7104



Document Created: 2015-08-14 17:06:21