Test Report

FCC ID: ZQXKS-3116

Test Report

Download: PDF
FCCID_4028230

           CERPASS TECHNOLOGY CORP.                             Report No.:TEFD1809102




                            FCC TEST REPORT
                                            According to

                            47 CFR, Part 2, Part 15, CISPR PUB. 22
                                      ICES 003 Issue 6

            Applicant       : Suzhou Switek Electronics&Technology Co, Ltd.
                                No.86, South WuSong Road, Luzhi Town, Wuzhong
            Address         :
                                District, Suzhou City.
            Equipment : KVM SWITCH
                        KS-3104(KT-150),KS-3104(KT-250)
            Model No. : KS-3108(KT-150),KS-3108(KT-250)
                        KS-3116(KT-150),KS-3116(KT-250)
            FCC ID          : ZQXKS-3116


           I HEREBY CERTIFY THAT :

           The sample was received on Sep 07, 2018 and the testing was carried out on Sep 17,
           2018 at Cerpass Technology Corp. The test result refers exclusively to the test
           presented test model / sample. Without written approval of Cerpass Technology Corp.,
           the test report shall not be reproduced except in full.



           Approved by




           Kero Kuo / EMC & RF Manager




Cerpass Technology Corp.                                                     Issued Date : Sep 20, 2018
Report format Revision 01                                                    Page No.    : 1 of 23


           CERPASS TECHNOLOGY CORP.                                 Report No.:TEFD1809102




                              FCC TEST REPORT
                                                  Issued by:




                                        Cerpass Technology Co.,Ltd

         No.10, Lane 2, Lianfu Street, Luzhu Township, Taoyuan County 33848, Taiwan(R.O.C.)

                                             Tel: 886-3-3226-888

                                            Fax: 886-3-3226-881


   The test record, data evaluation & Equipment. Under Test configurations represented herein
   are true and accurate accounts of the measurements of the samples EMC characteristics
   under the conditions specified in this report.




            Laboratory Accreditation:

                   Cerpass Technology Corporation Test Laboratory

                            TAF LAB Code:            1439




Cerpass Technology Corp.                                                        Issued Date : Sep 20, 2018
Report format Revision 01                                                       Page No.     : 2 of 23


              CERPASS TECHNOLOGY CORP.                                                            Report No.:TEFD1809102



                                                                         Contents

   1. Summary of Test Procedure and Test Result ....................................................................................... 5
       1.1. Applicable Standards................................................................................................................... 5
   2. Test Configuration of Equipment under Test ....................................................................................... 6
       2.1. Feature of Equipment under Test ................................................................................................. 6
       2.2. Test Manner ................................................................................................................................ 7
       2.3. Description of Test System .......................................................................................................... 8
       2.4. Connection Diagram of Test System ............................................................................................ 9
       2.5. General Information of Test ....................................................................................................... 10
       2.6. Measurement Uncertainty ......................................................................................................... 10
   3. Test of Conducted Emission ............................................................................................................... 11
       3.1. Test Limit .................................................................................................................................. 11
       3.2. Test Procedures ........................................................................................................................ 11
       3.3. Typical test Setup ...................................................................................................................... 12
       3.4. Measurement Equipment .......................................................................................................... 12
       3.5. Test Result and Data ................................................................................................................. 13
   4. Test of Radiated Emission .................................................................................................................. 15
          4.1.      Test Limit .................................................................................................................................. 15
          4.2.      Test Procedures ........................................................................................................................ 16
          4.3.      Typical test Setup ...................................................................................................................... 18
          4.4.      Measurement Equipment .......................................................................................................... 19
          4.5.      Test Result and Data (30MHz~1GHz) ........................................................................................ 20
          4.6.      Test Result and Data (1GHz ~18GHz) ....................................................................................... 22




Cerpass Technology Corp.                                                                                                   Issued Date : Sep 20, 2018
Report format Revision 01                                                                                                  Page No.          : 3 of 23


           CERPASS TECHNOLOGY CORP.                             Report No.:TEFD1809102

                                    History of this test report

            ORIGINAL.
            Additional attachment as following record:
            Report No          Version     Date           Description

            TEFD1809102        Rev 01      Sep 20, 2018   Initial Issue




Cerpass Technology Corp.                                                    Issued Date : Sep 20, 2018
Report format Revision 01                                                   Page No.     : 4 of 23


           CERPASS TECHNOLOGY CORP.                          Report No.:TEFD1809102

   1. Summary of Test Procedure and Test Result
     1.1. Applicable Standards
      The measurements shown in this test report were made in accordance with the procedures given in
      ANSI C63.4 – 2014 and the energy emitted by this equipment was passed Part 2, Part 15, CISPR
      PUB. 22.
      The energy emitted by this equipment was passed both Radiated and Conducted Emissions
      Class A limits.
                 Test Item          Normative References       Test Result              Remarks
                                                                                Meets Class A Limit
                                      ANSI C63.4-2014                            Minimum passing
          Conducted Emission        FCC Part 15 Subpart B         PASS
                                      ICES 003 Issue 6                       margin(QP) is -33.39 dB at
                                                                                    0.1500 MHz
                                                                                Meets Class A Limit
                                      ANSI C63.4-2014                            Minimum passing
           Radiated Emission        FCC Part 15 Subpart B         PASS
                                                                              margin(peak) is -7.08 dB
                                      ICES 003 Issue 6
                                                                                 at 207.5099 MHz




Cerpass Technology Corp.                                                     Issued Date : Sep 20, 2018
Report format Revision 01                                                    Page No.     : 5 of 23


           CERPASS TECHNOLOGY CORP.                                Report No.:TEFD1809102

2. Test Configuration of Equipment under Test
   2.1. Feature of Equipment under Test


        Product Name:            KVM SWITCH

                                 KS-3104(KT-150),KS-3104(KT-250)
        Model Name:              KS-3108(KT-150),KS-3108(KT-250)
                                 KS-3116(KT-150),KS-3116(KT-250)

                                 Model:         FJ-SW1260901000DU

        Adapter                  Input:         100-240V~ 50/60Hz 0.4A Max

                                 Output:        9V, 1000mA

         Note: Please refer to user manual.

        Model Different:

        Type                               4 Port              8 Port              16 Port
                                           KS-3104(KT-150)     KS-3108(KT-150)     KS-3116(KT-150)
        Model
                                           KS-3104(KT-250)     KS-3108(KT-250)     KS-3116(KT-250)
        Computer
                            Direct Connects 4                  8                   16
        Connection
                            Operating
                                           -10-50˚C
                            temperature
        Operating
                            Storage
        Environment                        -20-60˚C
                            temperature
                            Humidity       0-80%RH, No Condensation
                            Housing        Metal
        Physical
                            Dimension      432 x 155 x 44 mm
        Properties
                            Weight         0.8kg               0.8kg               0.8kg




Cerpass Technology Corp.                                                       Issued Date : Sep 20, 2018
Report format Revision 01                                                      Page No.      : 6 of 23


           CERPASS TECHNOLOGY CORP.                           Report No.:TEFD1809102


   2.2. Test Manner
         a. During testing, the interface cables and equipment positions were varied according to
             ANSI C63.4.
         b. Turn on the power of all equipment.
         c. The complete test system included PC, PS/2 Keyboard, USB Keyboard, USB Mouse, PS/2
             Mouse, Monitor, LAN to VGA + USB Docking and EUT for EMI test.
         d. The test mode as follow:
              Mode 1:       Full system for KS-3116(KT-150)
              Mode 2:       Full system for KS-3116(KT-250)
              Mode 3:       Full system for KS-3104(KT-150)
              Mode 4:       Full system for KS-3104(KT-250)
              Mode 5:       Full system for KS-3108(KT-150)
              Mode 6:       Full system for KS-3108(KT-250)
             The “Test Mode 1 were reported as final data.




Cerpass Technology Corp.                                                      Issued Date : Sep 20, 2018
Report format Revision 01                                                     Page No.    : 7 of 23


           CERPASS TECHNOLOGY CORP.                        Report No.:TEFD1809102


   2.3. Description of Test System
     No.    Device          Manufacturer   Model No.               Description
                                           HP Compaq Elite 8200
     1      PC              HP                                     Non-Shielded ,1.8m
                                           MTPC
     2      PS/2 Keyboard   ASUS           PK1100                  N/A
     3      USB Keyboard    DELL           SK-8115                 N/A
     4      USB Mouse       DELL           G0K02XYK                N/A
     5      PS/2 Mouse      FOXQUEEN       HM518                   N/A
     6      Monitor         Lenovo         L2364wA                 R33B65
            LAN to VGA +                                           N/A
     7                      OTECH          DT-5002A
            USB Docking




Cerpass Technology Corp.                                                 Issued Date : Sep 20, 2018
Report format Revision 01                                                Page No.    : 8 of 23


           CERPASS TECHNOLOGY CORP.                            Report No.:TEFD1809102


   2.4. Connection Diagram of Test System




     No.     Cable                    Quantity   Description
     A       LAN to VGA + USB Cable       1      Non-Shielded, 0.5m
     B       VGA Cable                    1      Non-Shielded, 1.8m,with two ferrite core bonded
     C       USB Cable                    1      Non-Shielded, 1.8m, with one ferrite core bonded
     D       USB Cable                    1      Non-Shielded, 1.5m
     E       PS/2 Cable                   1      Non-Shielded, 1.5m, with one ferrite core
     F       PS/2 Cable                   1      Non-Shielded, 1.5m
     G       LAN Cable                   15      Non-Shielded, 1.5m




Cerpass Technology Corp.                                                     Issued Date : Sep 20, 2018
Report format Revision 01                                                    Page No.    : 9 of 23


           CERPASS TECHNOLOGY CORP.                              Report No.:TEFD1809102


 2.5. General Information of Test

           Test Site :                      Cerpass Technology Corporation Test Laboratory
                                            Address: No.10, Ln. 2, Lianfu St., Luzhu Dist., Taoyuan City
                                            33848, Taiwan (R.O.C.)
                                            Tel:+886-3-3226-888
                                            Fax:+886-3-3226-881
                                            Address: No.68-1, Shihbachongsi, Shihding Township,
                                            New Taipei City 223, Taiwan, R.O.C.
                                            Tel: +886-2-2663-8582
           FCC Registration Number :        TW1079, TW1061

           IC Registration Number :         4934E-1, 4934E-2

                                            T-2205 for Telecommunication Test
                                            C-4663 for Conducted emission test
           VCCI
                                            R-4218 for Radiated emission test
                                            G-10812 for radiated disturbance above 1GHz
           Frequency Range                  Conducted Emission Test: from 150 kHz to 30 MHz
           Investigated :                   Radiated Emission Test: from 30 MHz to 18,000 MHz
                                            The test distance of radiated emission below 1GHz from
                                            antenna to EUT is 10 M.
           Test Distance :
                                            The test distance of radiated emission above 1GHz from
                                            antenna to EUT is 3 M.


 2.6. Measurement Uncertainty

           Measurement Item           Measurement Frequency      Polarization            Uncertainty
           Conducted Emission         9 kHz ~ 30 MHz             LINE / NEUTRAL          3.25 dB
                                      30 MHz ~ 1,000 MHz         Vertical / Horizontal   3.93 dB
           Radiated Emission
                                      1,000 MHz ~ 18,000 MHz     Vertical / Horizontal   5.18 dB




Cerpass Technology Corp.                                                          Issued Date : Sep 20, 2018
Report format Revision 01                                                         Page No.    : 10 of 23


           CERPASS TECHNOLOGY CORP.                                  Report No.:TEFD1809102


3. Test of Conducted Emission

   3.1. Test Limit
         Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 KHz
         on the 120 VAC power and return leads of the EUT according to the methods defined in
         ANSI C63.4-2014 Section 3.1. The EUT was placed on a nonmetallic stand in a shielded
         room 0.8 meters above the ground plane as shown in section 2.2. The interface cables
         and equipment positioning were varied within limits of reasonable applications to determine
         the position produced maximum conducted emissions.

         Conducted Emission Limits:

              Frequency range              Class A Equipment                 Class B Equipment
                    (MHz)             Quasi Peak         Average        Quasi Peak         Average
                 0.15 to 0.50              79               66            66 to 56*        56 to 46*
                   0.50 to 5               73               60               56               46
                   5. to 30.               73               60               60               50
            *The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to
             0.5MHz.



   3.2. Test Procedures
         a. The EUT was placed 0.4 meter from the conducting wall of the shielding room was kept at
            least 80 centimeters from any other grounded conducting surface.
         b. Connect EUT to the power mains through a line impedance stabilization network (LISN).
         c. All the support units are connecting to the other LISN.
         d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
         e. The FCC states that a 50 ohm, 50 micro-Henry LISN should be used.
         f. Both sides of AC line were checked for maximum conducted interference.
         g. The frequency range from 150 kHz to 30 MHz was searched.
         h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum
             Hold Mode.




Cerpass Technology Corp.                                                              Issued Date : Sep 20, 2018
Report format Revision 01                                                             Page No.     : 11 of 23


           CERPASS TECHNOLOGY CORP.                                Report No.:TEFD1809102

     3.3. Typical test Setup


                                              10cm




                              EUT



                                                                                    80cm

                      80cm


                                      80cm


                                                                40cm
               LISN                                                                  LISN

                                                         40cm




     3.4. Measurement Equipment
              Instrument       Manufacturer    Model No.        Serial No.   Calibration Date   Valid Date
             EMI Receiver           R&S          ESCI3           100821         2018/9/8         2019/9/7
           Line Impedance
              Stabilization    Schwarzbeck     NSLK 8127        8127-516        2018/9/12       2019/9/11
                Network
           Line Impedance
              Stabilization    Schwarzbeck     NSLK 8127        8127-568        2018/2/26       2019/2/25
                Network
             Pulse Limiter          R&S         ESH3-Z2          101934         2018/2/22       2019/2/21
               Software             Farad       Ez-EMC          ver.ct3a1          N/A              N/A




Cerpass Technology Corp.                                                            Issued Date : Sep 20, 2018
Report format Revision 01                                                           Page No.    : 12 of 23


           CERPASS TECHNOLOGY CORP.                                 Report No.:TEFD1809102

     3.5. Test Result and Data

         Test Mode :                Mode 1: Full system for KS-3116(KT-150)
         AC Power :                 AC 120V/60Hz          Phase :               LINE
         Temperature :              24°C                  Humidity :            53%
         Pressure(mbar) :           1002                  Date:                 2018/09/16




   No.    Frequency         Factor         Reading      Level          Limit          Margin       Detector
             (MHz)           (dB)          (dBuV)      (dBuV)          (dBuV)          (dB)
    1        0.1500          9.97           35.64       45.61          79.00           -33.39         QP
    2        0.1500          9.97           18.46       28.43          66.00           -37.57         AVG
    3        0.3100          9.97           29.64       39.61          79.00           -39.39         QP
    4        0.3100          9.97           22.14       32.11          66.00           -33.89         AVG
    5        0.5340          9.98           16.06       26.04          73.00           -46.96         QP
    6        0.5340          9.98           9.63        19.61          60.00           -40.39         AVG
    7        7.1220         10.20           18.37       28.57          73.00           -44.43         QP
    8        7.1220         10.20           11.06       21.26          60.00           -38.74         AVG
    9       13.9300         10.38           18.97       29.35          73.00           -43.65         QP
   10       13.9300         10.38           13.78       24.16          60.00           -35.84         AVG
    11      24.5820         10.60           20.84       31.44          73.00           -41.56         QP
   12       24.5820         10.60           14.23       24.83          60.00           -35.17         AVG
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                               Issued Date : Sep 20, 2018
Report format Revision 01                                                              Page No.    : 13 of 23


           CERPASS TECHNOLOGY CORP.                              Report No.:TEFD1809102



     Test Mode :             Mode 1: Full system for KS-3116(KT-150)
     AC Power :              AC 120V/60Hz           Phase :               NEUTRAL
     Temperature :           24°C                   Humidity :            53%
     Pressure(mbar) :        1002                   Date:                 2018/09/16




   No.    Frequency         Factor    Reading       Level        Limit          Margin       Detector
             (MHz)           (dB)      (dBuV)      (dBuV)        (dBuV)          (dB)
    1        0.1580          9.97       35.15       45.12        79.00          -33.88         QP
    2        0.1580          9.97       18.84       28.81        66.00          -37.19        AVG
    3        0.1780          9.97       32.73       42.70        79.00          -36.30         QP
    4        0.1780          9.97       15.63       25.60        66.00          -40.40        AVG
    5        0.3140          9.97       28.77       38.74        79.00          -40.26         QP
    6        0.3140          9.97       21.81       31.78        66.00          -34.22        AVG
    7        6.4020         10.18       16.19       26.37        73.00          -46.63         QP
    8        6.4020         10.18       8.76        18.94        60.00          -41.06        AVG
    9       14.2340         10.39       13.79       24.18        73.00          -48.82         QP
   10       14.2340         10.39       7.04        17.43        60.00          -42.57        AVG
    11      27.0900         10.66       20.30       30.96        73.00          -42.04         QP
   12       27.0900         10.66       14.01       24.67        60.00          -35.33        AVG
  Note: Measurement Level = Reading Level + Correct Factor




   Test engineer:




Cerpass Technology Corp.                                                          Issued Date : Sep 20, 2018
Report format Revision 01                                                         Page No.     : 14 of 23


           CERPASS TECHNOLOGY CORP.                               Report No.:TEFD1809102

4. Test of Radiated Emission
     4.1. Test Limit
   Below 1GHz (for digital device)

   For unintentional device, according to CISPR PUB.22, for Class B digital devices, the general requirement
   of field strength of radiated emissions from intentional radiators at a distance of 10 meters shall not
   exceed the below table.

                                                                   dBuV/m (At 10m)
             FREQUENCY (MHz)
                                                       Class A                          Class B
                   30 ~ 230                              40                               30
                  230 ~ 1000                             47                               37
   Limit tables for non-digital device:
   Class A Radiated Emission limit at 10m (for others)
          Frequency                  Field Strength Limit                    Field Strength Limit
            (MHZ)                         (uV/m)Q.P.                            (dBuV/m)Q.P.
             30 - 88                          90                                      39
            88 - 216                          150                                    43.5
           216 – 960                          210                                    46.4
          Above 960                           300                                    49.5

   Class B Radiated Emission limit at 3m (for others)
          Frequency                  Field Strength Limit                    Field Strength Limit
            (MHZ)                         (uV/m)Q.P.                            (dBuV/m)Q.P.
            30 - 88                           100                                     40
           88 - 216                           150                                    43.5
          216 – 960                           200                                     46
          Above 960                           500                                     54

   Above 1GHz(for all device)
                                 Class A (dBuV/m) (At 10m)                Class B (dBuV/m) (At 3m)
          Frequency
            (MHZ)
                                  Average              Peak             Average                Peak

          Above 1000                49.5               69.5                 54                  74

   NOTE: (1) The lower limit shall apply at the transition frequencies.
         (2) Emission level (dBuV/m) = 20 log Emission level (uV/m).
        (3) The measurement above 1GHz is at close-in distances 3m,and determine the limit L2
             corresponding to the close-in distance d2 by applying the following relation: L2 = L1 (d1/d2),
             where L1 is the specified limit in microvolts per metre (uV/m) at the distance d1 (10m), L2 is
             the new limit for distance d2 (3m).
            So the new Class A limit above 1GHz at 3m is as following table:




Cerpass Technology Corp.                                                          Issued Date : Sep 20, 2018
Report format Revision 01                                                         Page No.    : 15 of 23


            CERPASS TECHNOLOGY CORP.                               Report No.:TEFD1809102

                                                                   Class A (dBuV/m) (At 3m)
                       Frequency
                         (MHZ)
                                                                 Average                        Peak

                       Above 1000                                    60                          80
   According to FCC Part 15.33 (b), for an unintentional radiator, including a digital device, the spectrum
   shall be investigated from the lowest radio frequency signal generated or used in the device, without
   going below the lowest frequency for which a radiated emission limit is specified, up to the frequency
   shown in the following table:
     Highest frequency generated or used in the
                                                             Upper frequency of measurement range
   device or on which the device operates or tunes
                                                                                (MHz)
                              (MHz)
                            Below 1.75                                           30
                            1.75-108                                            1000
                             108-500                                            2000
                            500-1000                                            5000
                                                          5th harmonic of the highest frequency or 40GHz,
                        Above 1000
                                                                          whichever is lower


     4.2. Test Procedures

   Procedure of Preliminary Test

            The equipment was set up as per the test configuration to simulate typical usage per the user’s
             manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is
             used which is placed on the ground plane. When the EUT is a floor standing equipment, it is
             placed on the ground plane which has a 15 cm non-conductive covering to insulate the EUT
             from the ground plane.
            Support equipment, if needed, was placed as per ANSI C63.4.
            All I/O cables were positioned to simulate typical usage as per ANSI C63.4.
            The EUT received AC 120VAC/60Hz power source from the outlet socket under the turntable.
             All support equipment power received from another socket under the turntable.
            The antenna was placed at 3 or 10 meter away from the EUT as stated in ANSI C63.4. The
             antenna connected to the Spectrum Analyzer via a cable and at times a pre-amplifier would be
             used.
            The Analyzer / Receiver quickly scanned from 30MHz to 40GHz. The EUT test program was
             started. Emissions were scanned and measured rotating the EUT to 360 degrees and
             positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the
             horizontal polarization, to maximize the emission reading level.


Cerpass Technology Corp.                                                           Issued Date : Sep 20, 2018
Report format Revision 01                                                          Page No.    : 16 of 23


            CERPASS TECHNOLOGY CORP.                                 Report No.:TEFD1809102

            Set the spectrum analyzer/ Receiver in the following setting as:
             Below 1GHz:
             RBW=120KHz / VBW=300KHz / Sweep=AUTO
             Above 1GHz:
             Peak: RBW=1MHz, VBW=3MHz / Sweep=AUTO
             Average: RBW=1MHz / VBW=1.6Hz / Sweep=AUTO
            The worst configuration of EUT and cable of the above highest emission level were recorded
             for reference of the final test.

   Procedure of Final Test

            EUT and support equipment were set up on the turntable as per the configuration with highest
             emission level in the preliminary test.
            The Analyzer / Receiver scanned from 30MHz to 40GHz. Emissions were scanned and
             measured rotating the EUT to 360 degrees, varying cable placement and positioning the
             antenna 1 or 1 to 4 meters above the ground plane, in both the vertical and the horizontal
             polarization, to maximize the emission reading level.
            Recording at least the six highest emissions. Emission frequency, amplitude, antenna position,
             polarization and turntable position were recorded into a computer in which correction factors
             were used to calculate the emission level and compare reading to the applicable limit. Below
             1GHz the QP. reading and above 1GHz the Peak and Average reading are presented.
            The test data of the worst-case condition(s) was recorded.




Cerpass Technology Corp.                                                          Issued Date : Sep 20, 2018
Report format Revision 01                                                         Page No.    : 17 of 23


           CERPASS TECHNOLOGY CORP.                    Report No.:TEFD1809102

     4.3. Typical test Setup
           Below 1GHz Test Setup
                              Antenna


                                                                  Equipment under Test




                                        *   10 m

                                                                                         0.8M
                                                                          Turn




                                                   Ground Plane
            Receiver




          Above 1GHz Test Setup




Cerpass Technology Corp.                                                   Issued Date : Sep 20, 2018
Report format Revision 01                                                  Page No.      : 18 of 23


           CERPASS TECHNOLOGY CORP.                            Report No.:TEFD1809102

     4.4. Measurement Equipment
                                                                          Calibration
                 Instrument      Manufacturer      Model No.    Serial No.            Valid Date
                                                                            Date
               Bilog Antenna         Sunol            JB1       A020514-1 2018/2/23 2019/2/22
               Bilog Antenna         Sunol            JB1       A020514-2 2018/3/20 2019/3/19
                EMI Receiver         R&S             ESCI3       101402      2018/2/23 2019/2/22
                EMI Receiver         R&S             ESCI7       100963      2018/3/15 2019/3/14
                                 EM Electronics
                Preamplifier                        EM330         60610       2018/3/8    2019/3/7
                                     corp.
                                 EM Electronics
                Preamplifier                        EM330         60611      2018/2/26 2019/2/25
                                     corp.
               Horn Antenna       Schwarzbeck     BBHA 9120 D 9120D-1785 2017/9/27 2018/9/26
             Spectrum Analyzer       R&S            FSP40        100047      2018/3/20 2019/3/19
                                 EM Electronics
                Preamplifier                      EM01G18G        60700      2018/09/01 2019/08/31
                                     corp.
                                                                 Version:
                  Software            E3            AUDIX                       N/A         N/A
                                                                8.14.806b




Cerpass Technology Corp.                                                       Issued Date : Sep 20, 2018
Report format Revision 01                                                      Page No.    : 19 of 23


            CERPASS TECHNOLOGY CORP.                                    Report No.:TEFD1809102

     4.5. Test Result and Data (30MHz~1GHz)
         Test Mode :                Mode 1: Full system for KS-3116(KT-150)
         AC Power :                 AC 120V/60Hz           Ant. Polarization:      Horizontal
         Temp :                     25°C                   Humidity :              52%
         Pressure(mbar) :           1002                   Date:                   2018/09/17




   No.    Frequency     Factor        Reading      Level     Limit      Margin    Det.     Height      Azimuth
             (MHz)      (dB/m)         (dBuV)   (dBuV/m)   (dBuV/m)       (dB)                 (cm)      (deg)
    1       30.0000         -6.50       33.27      26.77     40.00       -13.23   peak         100        184
    2       71.7099     -17.25          41.25      24.00     40.00       -16.00   peak         100         52
    3      150.2800     -11.83          38.48      26.65     43.50       -16.85   peak         400        226
    4      204.5999     -13.13          46.50      33.37     43.50       -10.13   peak         400         36
    5      255.0399     -11.64          41.50      29.86     46.00       -16.14   peak         200        118
    6      319.0600         -8.99       35.36      26.37     46.00       -19.63   peak         200         78
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                            Issued Date : Sep 20, 2018
Report format Revision 01                                                           Page No.      : 20 of 23


            CERPASS TECHNOLOGY CORP.                                    Report No.:TEFD1809102



   Test Mode :                      Mode 1: Full system for KS-3116(KT-150)
   AC Power :                       AC 120V/60Hz           Ant. Polarization:      Vertical
   Temp :                           25°C                   Humidity :              52%
   Pressure(mbar) :                 1002                   Date:                   2018/09/17




   No.   Frequency      Factor        Reading      Level     Limit      Margin    Det.        Height    Azimuth
            (MHz)       (dB/m)         (dBuV)   (dBuV/m)   (dBuV/m)       (dB)                 (cm)      (deg)
    1       32.9099         -8.07       38.92      30.85     40.00       -9.15    peak         100         61
    2     176.4698      -12.71          43.71      31.00     43.50       -12.50   peak         100        151
    3     207.5099      -13.05          49.47      36.42     43.50       -7.08    peak         400        128
    4     255.0399      -11.64          39.69      28.05     46.00       -17.95   peak         200        223
    5     535.3700          -3.26       34.09      30.83     46.00       -15.17   peak         200         25
    6     604.2400          -1.78       30.50      28.72     46.00       -17.28   peak         400         117
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                            Issued Date : Sep 20, 2018
Report format Revision 01                                                           Page No.      : 21 of 23


            CERPASS TECHNOLOGY CORP.                                    Report No.:TEFD1809102

     4.6. Test Result and Data (1GHz ~18GHz)


   Test Mode :                      Mode 1: Full system for KS-3116(KT-150)
   AC Power :                       AC 120V/60Hz           Ant. Polarization:      Horizontal
   Temp :                           25°C                   Humidity :              52%
   Pressure(mbar) :                 1002                   Date:                   2018/09/17




   No.   Frequency      Factor        Reading      Level     Limit      Margin    Det.     Height      Azimuth
            (MHz)       (dB/m)         (dBuV)   (dBuV/m)   (dBuV/m)       (dB)                 (cm)      (deg)
    1     2462.000          -1.97       43.93      41.96     80.00       -38.04   peak         200        185
    2     3091.000          -0.72       42.98      42.26     80.00       -37.74   peak         100        227
    3     3567.000          1.81        43.45      45.26     80.00       -34.74   peak         200        204
    4     4281.000          3.02        44.36      47.38     80.00       -32.62   peak         100         78
    5    13818.000      20.82           32.41      53.23     80.00       -26.77   peak         100        300
    6    14940.000      22.14           33.40      55.54     80.00       -24.46   peak         189        360
  Note: Measurement Level = Reading Level + Correct Factor




Cerpass Technology Corp.                                                            Issued Date : Sep 20, 2018
Report format Revision 01                                                           Page No.      : 22 of 23


            CERPASS TECHNOLOGY CORP.                                    Report No.:TEFD1809102



   Test Mode :                      Mode 1: Full system for KS-3116(KT-150)
   AC Power :                       AC 120V/60Hz           Ant. Polarization:      Vertical
   Temp :                           25°C                   Humidity :              52%
   Pressure(mbar) :                 1002                   Date:                   2018/09/17




   No.   Frequency      Factor        Reading      Level     Limit      Margin    Det.        Height      Azimuth
            (MHz)       (dB/m)         (dBuV)   (dBuV/m)   (dBuV/m)      (dB)                 (cm)          (deg)
    1     1493.000          -5.83       49.21      43.38     80.00       -36.62   peak         169           360
    2     2122.000          -3.24       45.65      42.41     80.00       -37.59   peak         200           328
    3     4230.000          3.10        42.87      45.97     80.00       -34.03   peak         200            2
    4     9160.000          9.12        40.30      49.42     80.00       -30.58   peak         200           141
    5    14022.000      21.72           32.11      53.83     80.00       -26.17   peak         100           191
    6    15399.000      22.23           33.29      55.52     80.00       -24.48   peak         100           274
  Note: Measurement Level = Reading Level + Correct Factor




   Test engineer: