Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 6/24/2015 11:42:39 AM

20150624_SystemPerformanceCheck-D835V2 SN 4d117

Frequency: 835 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 835 MHz; σ = 0.997 S/m; εr = 53.277; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/7/2014
- Probe: EX3DV4 - SN3929; ConvF(8.57, 8.57, 8.57); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM; Type: QD000P40CD; Serial: TP 1751

Body/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.21 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 35.760 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 1.47 W/kg
SAR(1 g) = 1.02 W/kg; SAR(10 g) = 0.675 W/kg
Maximum value of SAR (measured) = 1.23 W/kg




                      0 dB = 1.23 W/kg = 0.90 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc., SAR Lab 1   Date/Time: 6/24/2015 12:01:28 PM

20150624_SystemPerformanceCheck-D835V2 SN 4d117
Frequency: 835 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 1.21 W/kg




                                                                                           Plot No. 2


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 6/23/2015 8:55:34 PM

20150623_SystemPerformanceCheck-D1900V2 SN 5d163

Frequency: 1900 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1900 MHz; σ = 1.529 S/m; εr = 51.827; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1380; Calibrated: 7/23/2014
- Probe: EX3DV4 - SN3749; ConvF(7.09, 7.09, 7.09); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

Body/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 5.74 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 61.93 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 7.67 W/kg
SAR(1 g) = 4.17 W/kg; SAR(10 g) = 2.16 W/kg
Maximum value of SAR (measured) = 5.63 W/kg




                      0 dB = 5.63 W/kg = 7.51 dBW/kg




                                                                                                               Plot No. 3


Test Laboratory: UL Verification Services Inc., SAR Lab 3   Date/Time: 6/23/2015 9:12:55 PM

20150623_SystemPerformanceCheck-D1900V2 SN 5d163
Frequency: 1900 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 5.63 W/kg




                                                                                              Plot No. 4


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 6/24/2015 10:15:22 AM

20150624_SystemPerformanceCheck-D835V2 SN 4d117

Frequency: 835 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                              3
Medium parameters used: f = 835 MHz; σ = 0.925 S/m; εr = 43.04; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1380; Calibrated: 7/23/2014
- Probe: EX3DV4 - SN3749; ConvF(8.75, 8.75, 8.75); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.18 W/kg

Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 36.12 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 1.45 W/kg
SAR(1 g) = 0.971 W/kg; SAR(10 g) = 0.639 W/kg




                       0 dB = 1.18 W/kg = 0.72 dBW/kg




                                                                                                               Plot No. 5


Test Laboratory: UL Verification Services Inc., SAR Lab 3   Date/Time: 6/24/2015 10:32:30 AM

20150624_SystemPerformanceCheck-D835V2 SN 4d117
Frequency: 835 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 1.19 W/kg




                                                                                           Plot No. 6


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 6/26/2015 10:11:48 AM

20150626_SystemPerformanceCheck-D1900V2 SN 5d163

Frequency: 1900 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1900 MHz; σ = 1.416 S/m; εr = 39.363; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1380; Calibrated: 7/23/2014
- Probe: EX3DV4 - SN3749; ConvF(7.34, 7.34, 7.34); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 5.38 W/kg

Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 62.41 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 7.29 W/kg
SAR(1 g) = 3.91 W/kg; SAR(10 g) = 2.02 W/kg
Maximum value of SAR (measured) = 5.28 W/kg




                       0 dB = 5.28 W/kg = 7.23 dBW/kg




                                                                                                               Plot No. 7


Test Laboratory: UL Verification Services Inc., SAR Lab 3   Date/Time: 6/26/2015 10:28:42 AM

20150626_SystemPerformanceCheck-D1900V2 SN 5d163
Frequency: 1900 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 5.27 W/kg




                                                                                           Plot No. 8


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 6/30/2015 2:56:37 PM

20150630_SystemPerformanceCheck-D835V2 SN 4d142

Frequency: 835 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 835 MHz; σ = 1.017 S/m; εr = 52.796; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(8.61, 8.61, 8.61); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

Body/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.07 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 32.96 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 1.30 W/kg
SAR(1 g) = 0.884 W/kg; SAR(10 g) = 0.586 W/kg




                       0 dB = 1.07 W/kg = 0.29 dBW/kg




                                                                                                               Plot No. 9


Test Laboratory: UL Verification Services Inc., SAR Lab 3   Date/Time: 6/30/2015 3:13:48 PM

20150630_SystemPerformanceCheck-D835V2 SN 4d142
Frequency: 835 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 1.07 W/kg




                                                                                          Plot No. 10