TCoil Test Report

FCC ID: ZNFUN160

Test Report

Download: PDF
FCCID_1852759

                           PCTEST ENGINEERING LABORATORY, INC.
                                             6660-B Dobbin Road, Columbia, MD 21045 USA
                                                 Tel. 410.290.6652 / Fax 410.290.6554
                                                        http://www.pctestlab.com


                                       HEARING AID COMPATIBILITY
Applicant Name:                                                                Date of Testing:
LG Electronics USA                                                             Novemeber 16-17, 2012
1000 Sylvan Avenue                                                             Test Site/Location:
Englewood Cliffs, NJ 07632                                                     PCTEST Lab, Columbia, MD, USA
United States                                                                  Test Report Serial No.:
                                                                               0Y1211121637.ZNF


FCC I D:                                           ZNFUN160

APPLI C A NT:                                      LG ELECTRONICS USA

Scope of Test:                                     Audio Band Magnetic Testing (T-Coil)
FCC Rule Part(s):                                  CFR § 20.19(b)
HAC Standard:                                      ANSI C63.19-2007 §6.3(v), §7.3(v)
EUT Type:                                          Portable Handset
Model(s):                                          UN160, LGUN160, LG-UN161, UN161, LGUN161
Tx Frequencies Tested:                             824.70 - 848.31 MHz (Cellular CDMA)
                                                   1711.25 - 1753.75 MHz (AWS CDMA)
                                                   1851.25 - 1908.75 MHz (PCS CDMA)
Test Device Serial No.:                            Pre-Production Sample [S/N: HAC #2 T-coil]


C63.19-2007 HAC Category:                          T4 (SIGNAL TO NOISE CATEGORY)

This wireless portable device has been shown to be hearing-aid compatible under the above rated category, specified in ANSI/IEEE
Std. C63.19-2007 and had been tested in accordance with the specified measurement procedures. Hearing-Aid Compatibility is
based on the assumption that all production units will be designed electrically identical to the device tested in this report. Test results
reported herein relate only to the item(s) tested. For North American bands only.

I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and
are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and
vouch for the qualifications of all persons taking them.

PCTEST certifies that no party to this application has been subject to a denial of Federal benefits that includes FCC benefits
pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862.




                                                                                                                           Reviewed by:
FCC ID: ZNFUN160                                             HAC (T-COIL) TEST REPORT
                                                                                                                           Quality Manager
Filename:                     Test Dates:                      EUT Type:
                                                                                                                           Page 1 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012              Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                       REV 6.4C
                                                                                                                                  04/05/10


                                   T A B L E                   O F           C O N T E N T S




1.          INTRODUCTION ............................................................................................................................. 3

2.          TEST SITE LOCATION ................................................................................................................... 4

3.          EUT DESCRIPTION ........................................................................................................................ 5

4.          ANSI C63.19-2007 PERFORMANCE CATEGORIES .................................................................... 6

5.          METHOD OF MEASUREMENT ...................................................................................................... 8

6.          TEST SUMMARY .......................................................................................................................... 18

7.          FCC 3G MEASUREMENTS .......................................................................................................... 22

8.          MEASUREMENT UNCERTAINTY ................................................................................................ 23

9.          EQUIPMENT LIST ......................................................................................................................... 24

10.         CALIBRATION CERTIFICATES.................................................................................................... 25

11.         CONCLUSION ............................................................................................................................... 32

12.         REFERENCES .............................................................................................................................. 33

13.         TEST SETUP PHOTOGRAPHS ................................................................................................... 35




                                                                                                                                       Reviewed by:
FCC ID: ZNFUN160                                                   HAC (T-COIL) TEST REPORT
                                                                                                                                       Quality Manager
Filename:                        Test Dates:                          EUT Type:
                                                                                                                                       Page 2 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                     Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                                    REV 6.4C
                                                                                                                                               04/05/10


1.          INTRODUCTION

On July 10, 2003, the Federal Communications Commission (FCC) adopted new rules requiring wireless
manufacturers and service providers to provide digital wireless phones that are compatible with hearing
aids. The FCC has modified the exemption for wireless phones under the Hearing Aid Compatibility Act of
1998 (HAC Act) in WT Docket 01-309 RM-8658 1 to extend the benefits of wireless telecommunications to
individuals with hearing disabilities. These benefits encompass business, social and emergency
communications, which increase the value of the wireless network for everyone. Approximately 500
million people worldwide and 30 million people in the United States suffer from hearing loss.


Compatibility Tests Involved:

The standard calls for wireless communications devices to be measured for:
    RF Electric-field emissions
    RF Magnetic-field emissions
    T-coil mode, magnetic-signal strength in the audio band
    T-coil mode, magnetic-signal frequency response through the audio band
    T-coil mode, magnetic-signal and noise articulation index

The hearing aid must be measured for:
    RF immunity in microphone mode
    RF immunity in T-coil mode

In the following tests and results, this report includes the evaluation for a wireless communications
device.




                                             Figure 1-1 Hearing Aid in-vitu




1
    FCC Rule & Order, WT Docket 01-309 RM-8658

                                                                                                Reviewed by:
FCC ID: ZNFUN160                                      HAC (T-COIL) TEST REPORT
                                                                                                Quality Manager
Filename:                   Test Dates:                EUT Type:
                                                                                                Page 3 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012      Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                              REV 6.4C
                                                                                                         04/05/10


2.          TEST SITE LOCATION

I.      Introduction
The map at the right shows the location of the PCTEST
LABORATORY in Columbia, Maryland. It is in proximity to the FCC
Laboratory, the Baltimore-Washington International (BWI) airport,
the city of Baltimore and Washington, DC (See Figure 2-1).

These measurement tests were conducted at the PCTEST
Engineering Laboratory, Inc. facility in New Concept Business Park,
Guilford Industrial Park, Columbia, Maryland. The site address is
6660-B Dobbin Road, Columbia, MD 21045. The test site is one of
the highest points in the Columbia area with an elevation of 390
feet above mean sea level. The site coordinates are 39° 11’15” N
latitude and 76° 49’ 38” W longitude. The facility is 1.5 miles north
of the FCC laboratory, and the ambient signal and ambient signal
strength are approximately equal to those of the FCC laboratory.
There are no FM or TV transmitters within 15 miles of the site. The                      Figure 2-1
detailed description of the measurement facility was found to be in             Map of the Greater Baltimore
compliance with the requirements of § 2.948 according to ANSI                  and Metropolitan Washington,
C63.4-2003 on January 27, 2006 and Industry Canada.                                      D.C. Area

II.     Test Facility / Accreditations:

Measurements were performed at an independent accredited PCTEST Engineering Lab located in
Columbia, MD 21045, U.S.A.
                     •    PCTEST Lab is accredited to ISO 17025-2005 by the American Association for
                          Laboratory Accreditation (A2LA) in Specific Absorption Rate (SAR) testing, Hearing-
                          Aid Compatibility (HAC), CTIA Test Plans, and wireless testing for FCC and Industry
                          Canada Rules.
                     •    PCTEST Lab is accredited to ISO 17025 by U.S. National Institute of Standards and
                          Technology (NIST) under the National Voluntary Laboratory Accreditation Program
                          (NVLAP Lab code: 100431-0) in EMC, FCC and Telecommunications.
                     •    PCTEST facility is an FCC registered (PCTEST Reg. No. 90864) test facility with the
                          site description report on file and has met all the requirements specified in Section
                          2.948 of the FCC Rules and Industry Canada (IC-2451).
                     •    PCTEST Lab is a recognized U.S. Conformity Assessment Body (CAB) in EMC and
                          R&TTE (n.b. 0982) under the U.S.-EU Mutual Recognition Agreement (MRA).
                     •    PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to
                          ISO/IEC Guide 65 by the American National Standards Institute (ANSI) in all scopes
                          of FCC Rules and all Industry Canada Standards (RSS).
                     •    PCTEST facility is an IC registered (IC-2451) test laboratory with the site description
                          on file at Industry Canada.
                     •    PCTEST is a CTIA Authorized Test Laboratory (CATL) for AMPS and CDMA, and
                          EvDO mobile phones.
                     •    PCTEST is a CTIA Authorized Test Laboratory (CATL) for Over-the-Air (OTA)
                          Antenna Performance testing for AMPS, CDMA, GSM, GPRS, EGPRS, UMTS (W-
                          CDMA), CDMA 1xEVDO Data, CDMA 1xRTT Data.



                                                                                                    Reviewed by:
FCC ID: ZNFUN160                                    HAC (T-COIL) TEST REPORT
                                                                                                    Quality Manager
Filename:                   Test Dates:              EUT Type:
                                                                                                    Page 4 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012    Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                REV 6.4C
                                                                                                           04/05/10


k           EUT DESCRIPTION



                                                             @ 1c
FCC ID:                                             ZNFUN160
Applicant:                                          LG Electronics USA
                                                    1000 Sylvan Avenue
                                                    Englewood Cliffs, NJ 07632
                                                    United States
Model(s):                                           UN160, LGUN160, LG—UN161, UN161, LGUN161
Serial Number:                                      HAC #2 T—coil
Tx Frequencies Tested:                              824.70 — 848.31 MHz (Cellular CDMA)
                                                    1711.25 — 1753.75 MHz (AWS CDMA)
                                                    1851.25 — 1908.75 MHz (PCS CDMA)
HW Version:                                         Revision B
SW Version:                                         UN160C01
                                                    24.82 dBm (Cell. CDMA), 24.93 dBm (AWS CDMA), 25.1
Maximum Conducted Power (HAC):
                                                    dBm (PCS CDMA)
Antenna:                                            Internal Antenna
HAC Test Configurations:                            Cell. CDMA, 1013, 384, 777, BT Off
                                                    AWS CDMA, 25, 450, 875, BT Off
                                                    PCS CDMA, 25, 600, 1175, BT Off
EUT Type:                                           Portable Handset


  Ai—Interface        Band                Type            C63.19      Simultaneous Transmissions    R:::’c:rd     Vom_:g::;::_'tg'tal
                      (MHz)                               tested           (Not to be tested)       2048 (GG)           (Data)

                       850
    CDMA               1700              Voice             Yes                  Yes: BT                N/A               N/A
                       1900
      BI               2450               Data             N/A                 Yes: CDMA               N/A               N/A
     NOTE: HAC Rating was not based on concurrent vaice and data modes. Standalone made was found to represent worst case rating.

                                             Table 3: ZNFUN160 Air Interfaces




                                                                                                                                 Reviewed by:
FCC ID: ZNFUN160                                                 HAC (T—COIL} TEST REPORT                                               .
                                                                                                                                 Quality Manager
Filename:                      Test Dates:                         EUT Type:                                                     Page 5 of 37
0Y1211121637.2NF               Novemeber 16—17, 2012               Portable Handset                                                 9
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                                  REV 6.4C
                                                                                                                                            04/05710


4.          ANSI C63.19-2007 PERFORMANCE CATEGORIES

I.      MAGNETIC COUPLING

Axial and Radial Field Intensity

     All orientations of the magnetic field, in the axial, horizontal and vertical position along the
     measurement plane shall be ≥ -18 dB(A/m) at 1 kHz in a 1/3 octave band filter per 7.3.1.
Frequency Response

     The frequency response of the axial component of the magnetic field shall follow the response curve
     specified in EIA RS-504-1983, over the frequency range 300 Hz – 3000 Hz per 7.3.2.

                                                                                            MAGNETIC FIELD STRENGTH RELATIVE TO 1000 Hz
                                                                     20
                           dB Relative to Value at 1 kHz




                                                                                                                     -4 dB/Oct.
                                                                     10
                                                                                                                                                               +2 dB

                                                                                                         -2 dB
                                                                          0
                                                                                                                                                                       -6 dB/Oct.


                                                                    -10
                                                                                                         6 dB/Oct.


                                                                    -20
                                                                              300                                500                  1000        2000                              3000
                                                                                                                                   FREQUENCY (Hz)

                                                   Figure 4-1
                   Magnetic field frequency response for Wireless Devices with an axial field
                                            ≤ -15 dB (A/m) at 1 kHz

                                                                               MAGNETIC FIELD STRENGTH RELATIVE TO 1000 Hz
                                                              20


                                                                                            -4 dB/Oct.
                              dB Relative to Value at 1 kHz




                                                              10
                                                                                                                                   +2 dB


                                                                                    -2 dB
                                                               0
                                                                                                                                           -7 dB/Oct.


                                                              -10

                                                                                6 dB/Oct.
                                                                                                                                      -12 dB/Oct.
                                                              -20
                                                                    300                     500                  1000              2000                 3000
                                                                                                             FREQUENCY (Hz)




                                                 Figure 4-2
            Magnetic Field frequency response for wireless devices with an axial field that exceeds
                                           -15 dB(A/m) at 1 kHz

                                                                                                                                                                                           Reviewed by:
FCC ID: ZNFUN160                                                                                                        HAC (T-COIL) TEST REPORT
                                                                                                                                                                                           Quality Manager
Filename:                           Test Dates:                                                                               EUT Type:
                                                                                                                                                                                           Page 6 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                                                                             Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                                                                                       REV 6.4C
                                                                                                                                                                                                  04/05/10


Signal Quality

     The table below provides the signal quality requirement for the intended audio magnetic signal from a
     wireless device. Only the RF immunity of the hearing aid is measured in T-coil mode. It is assumed
     that a hearing aid can have no immunity to an interference signal in the audio band, which is the
     intended reception band for this mode. The only criterion that can be measured is the RF immunity in
     T-coil mode. This is measured using the same procedure as the audio coupling mode at the same
     levels.

     The signal quality of the axial and radial components of the magnetic field was used to determine the
     T-coil mode category.


                                                         Telephone RF Parameters
                                   Category
                                                       Wireless Device Signal Quality
                                                    (Signal + Noise-to-noise ratio in dB)
                                          T1                     0 to 10 dB
                                          T2                    10 to 20 dB
                                          T3                     20 to 30 dB
                                          T4                       > 30 dB

                                                         Table 4-1
                                               Magnetic Coupling Parameters




                                                                                              Reviewed by:
FCC ID: ZNFUN160                                         HAC (T-COIL) TEST REPORT
                                                                                              Quality Manager
Filename:                   Test Dates:                    EUT Type:
                                                                                              Page 7 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012          Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                          REV 6.4C
                                                                                                     04/05/10


5.          METHOD OF MEASUREMENT


I.      Test Setup
     The equipment was connected as shown in an acoustic/RF hemi-anechoic chamber:




                                  Figure 5-1 Validation Setup with Helmholtz Coil




                                              Figure 5-2 T-Coil Test Setup




                                                                                     Reviewed by:
FCC ID: ZNFUN160                                      HAC (T-COIL) TEST REPORT
                                                                                     Quality Manager
Filename:                   Test Dates:                EUT Type:
                                                                                     Page 8 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012      Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                 REV 6.4C
                                                                                            04/05/10


II.        Scanning Mechanism

Manufacturer:                               TEM
Accuracy:                                   + 0.83 cm/meter
Minimum Step Size:                          0.1 mm
Maximum speed                               6.1 cm/sec
Line Voltage:                               115 VAC
Line Frequency:                             60 Hz
Material Composite:                         Delrin (Acetal)
Data Control:                               Parallel Port                                                   Figure 5—3
Dynamic Range (X—Y—Z2):                     45 x 31.75 x 47 cm                                        RF Near—Field Scanner
Dimensions:                                 36" x 25" x 38"
Operating Area:                             36" x 49" x 55"
Reflections:                                <—20 dB (in anechoic chamber)



IIL.       ITU—T P.50 Artificial Voice
Manufacturer:                     ITU—T
Active Frequency                  100 Hz —8 kHz
Range:
Stimulus Type:                    Male and Female, no spaces
Single Sample Duration:           20.96 seconds
Activity Level:                   100%


                                                                                                           Figur; 5—4
                                                                                               Spectral Characteristic of full P.50




                                                              Figure 5—5
                                              Temporal Characteristic of full P.50




                             £) RCTEsT —                                                                                 Reviewed by:
       :                     ©                                HAC       (T—COIL} TEST REPORT                   Li
FGG ID: ZNFUN160             J\’—                                   T        )                              @ 6          Quality Manager
 i
Filename :                   Test Dates :                      EUT Type:
                                                                    ype                                                  Page 9 of 37
0Y1211121637.2NF             Novemeber 16—17, 2012             Portable Handset
©2012 PCTEST Engineering Laboratory, Inc.                                                                                       REV 6.4C
                                                                                                                                 04/05710


 ABM1 Measurement Block Diagram:

                  Raw Probe
                 Measurement
                    (mV)
                                                                 T-Coil Probe                            1 kHz bin,
 1kHz through                   40                                                      40 dB
                                                              Sensitivity Factor                         1/3-octave                                ABM1
     WD                         dB                                                  pre-gain factor
                                                              (-59.09 dBV/A/m)                              filter




 ABM2 Measurement Block Diagram:
                  Raw Probe
                 Measurement
                    (mV)
                                                T-Coil Probe            40 dB
                               40                                                       Half-Band           IEC179          100Hz-10kHz
      noise                                  Sensitivity Factor        pre-gain                                                                    ABM2
                               dB                                                    Integrator curve   A-weighting curve    Power Sum
                                             (-59.09 dBV/A/m)           factor



                                   Figure 5-6 Magnetic Measurement Processing Steps

IV.           Test Procedure

       1. Ambient Noise Check per C63.19 §6.2.1
             a. Ambient interference was monitored using a Real-Time Analyzer between 100-10,000 Hz
                 with 1/3 octave filtering.
             b. “A-weighting” and Half-Band Integration was applied to the measurements.
             c. Since this measurement was measured in the same method as ABM2 measurements,
                 this level was verified to be less than 10 dB below the lowest measurement signal (which
                 is the highest ABM2 measurement for a T4 WD). Therefore the maximum noise level for
                 a T4 WD with an ABM1 = -18 dBA/m is:
                                            -18 - 30 - 10 = -58 dBA/m

      2. Measurement System Validation (See Figure 5-1)
            a. The measurement system including the probe, pre-amplifier and acquisition system were
               validated as an entire system to ensure the reliability of test measurements.

                  b. ABM1 Validation
                     The magnetic field at the center of the Helmholtz coil is given by the equation (per
                     C63.19 Annex D.9.1):
                                                                                         V
                                                                                       N( )
                                                                             NI           R
                                                                      Hc =          =
                                                                                  3
                                                                           r 1.25     r 1.25 3
                                Where Hc = magnetic field strength in amperes per meter
                                      N = number of turns per coil

                        For the Helmholtz Coil, N=20; r=0.08m; R=10.193Ω and using V=57mV:

                                                                             0.057
                                                                           20 ⋅ (  )
                                                                  Hc =      10.193 = 1.0003 A / m
                                                                       0.08 ⋅ 1.25 3
                        Therefore a pure tone of 1kHz was applied into the coils such that 57 mV was observed
                        across the 10 Ω resistor. The voltmeter used for measurement was verified to be capable
                        of measurements in the audio band range. This theoretically generates an expected field
                        of 1 A/m in the center of the Helmholtz coil which was used to validate the probe


                                                                                                                                          Reviewed by:
FCC ID: ZNFUN160                                                     HAC (T-COIL) TEST REPORT
                                                                                                                                          Quality Manager
Filename:                      Test Dates:                              EUT Type:
                                                                                                                                          Page 10 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                       Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                                      REV 6.4C
                                                                                                                                                 04/05/10


                      measurement at 1 A/m. This was verified to be within ± 0.5 dB of the 1 A/m value (see
                      Page 19).

               c.     Frequency Response Validation

                      The frequency response through the Helmholtz Coil was verified to be within 0.5 dB
                      relative to 1 kHz, between 300 – 3000 Hz using the ITU-P.50 artificial speech signal as
                      shown below:

                                                                                                                               Frequency
     P.50           Helmholtz                 40       Probe                      40 dB      Full-Band    Subtract P.50       Response of
                                                      Sensitivity                pre-gain    Integrator      stimulus
   stimulus           Coil                    dB                                  factor       curve                           Helmholtz
                                                      (-59.09 dBV/A/m)                                     frequency              Coil
                                                                                                            character


                                         Figure 5-7 Frequency Response Validation

               d. ABM2 Measurement Validation

                      WD noise measurements are filtered with A-weighting and Half-Band Integration over a
                      frequency range of 100Hz – 10kHz to process ABM2 measurements. Below is the
                      verification of the system processing A-weighting and Half-Band integration between
                      system input to output within 0.5 dB of the theoretical result:


                                                                     Table 5-1
                                                       ABM2 Frequency Response Validation
                                                             HBI, A -        HBI, A -
                                                   f (Hz)   Measured      Theoretical dB Var.
                                                           (dB re 1kHz) (dB re 1kHz)
                                                    100      -16.180         -16.170   -0.010
                                                    125      -13.257         -13.250   -0.007
                                                    160      -10.347         -10.340   -0.007
                                                    200       -8.017          -8.010   -0.007
                                                    250       -5.925          -5.920   -0.005
                                                    315       -4.045          -4.040   -0.005
                                                    400       -2.405          -2.400   -0.005
                                                    500       -1.212          -1.210   -0.002
                                                    630       -0.349          -0.350    0.001
                                                    800        0.071           0.070    0.001
                                                   1000        0.000           0.000    0.000
                                                   1250       -0.503          -0.500   -0.003
                                                   1600       -1.513          -1.510   -0.003
                                                   2000       -2.778          -2.780    0.002
                                                   2500       -4.316          -4.320    0.004
                                                   3150       -6.166          -6.170    0.004
                                                   4000       -8.322          -8.330    0.008
                                                   5000      -10.573         -10.590    0.017
                                                   6300      -13.178         -13.200    0.022
                                                   8000      -16.241         -16.270    0.029
                                                   10000     -19.495         -19.520   0.025


                                                                                                                          Reviewed by:
FCC ID: ZNFUN160                                                  HAC (T-COIL) TEST REPORT
                                                                                                                          Quality Manager
Filename:                       Test Dates:                          EUT Type:
                                                                                                                          Page 11 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                    Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                      REV 6.4C
                                                                                                                                 04/05/10


                                                                               ABM2 Frequency Response Validation (LISTEN)

                                                       10




                                                        0
                                                         100                                       1000                                            10000



                                                       -10




                                dBV, A weighted, HBI
                                                       -20




                                                       -30

                                                                                                                 HBI, A - Measured
                                                                                                                 HBI, A - Theoretical

                                                       -40




                                                       -50
                                                                                               Frequency (Hz)


                                                                               Figure 5-8
                                                                   ABM2 Frequency Response Validation

                    The ABM2 result is a power sum from 100 Hz to 10 kHz with half-band integration and A-
                    weighting. To verify the power sum measurement, a power sum over the full band was
                    measured and verified to track with the source level (See Figure 5-9). Therefore the
                    setup in this step was used to verify the power sum post-processing for ABM2
                    measurements. See below block diagram:

                                                                      Half-Band                IEC179                          100Hz-10kHz
                                                        noise                                                                                      “ABM2”
                                                                   Integrator curve        A-weighting curve                    Power Sum




                                                                      Half-Band                 IEC179                                               ABM2
                                                        noise                                                                     Multmeter
                                                                   Integrator curve         A-weighting curve                                      using MM


                                                                         Figure 5-9
                                                                ABM2 Validation Block Diagram

                    The power summed output results for a known input were compared to the multi-meter
                    results to verify any deviation in the post-processing implemented with the power-sum.

                                                                                   Table 5-2
                                                                            ABM2 Power Sum Validation
                                                                 WN Input         Power Sum               Multimeter-Full
                                                                                                                                        Dev (dB)
                                                                  (dBV)             (dBV)                      (dBV)

                                                                    -60               -60.36                    -60.2                     0.16
                                                                    -50               -50.19                    -50.13                    0.06
                                                                    -40               -40.14                    -40.03                    0.11
                                                                    -30               -30.13                    -30.01                    0.12
                                                                    -20               -20.12                     -20                      0.12
                                                                    -10               -10.14                     -10                      0.14


                                                                                                                                                           Reviewed by:
FCC ID: ZNFUN160                                                             HAC (T-COIL) TEST REPORT
                                                                                                                                                           Quality Manager
Filename:                   Test Dates:                                         EUT Type:
                                                                                                                                                           Page 12 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                               Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                                                       REV 6.4C
                                                                                                                                                                  04/05/10


                                                                                      ABM2 Power Sum Validation (LISTEN)

                                                     -10




                                                     -20




                                                     -30




                              Measured Level (dBV)
                                                     -40

                                                                                                                                Power Sum (dBV)
                                                                                                                                Multimeter-Full (dBV)


                                                     -50




                                                     -60




                                                     -70
                                                           -60   -55     -50    -45        -40        -35         -30     -25       -20             -15   -10
                                                                                                 WN Input (dBV)


                                                                                      Figure 5-10
                                                                               ABM2 Power Sum Validation

     3. Measurement Test Setup
           a. Fine scan above the WD (TEM)
                   i. A multitone signal was applied to the handset such that the phone acoustic
                      output was stable within 1dB over the probe settling time and with the acoustic
                      output level at the C63.19 specified levels (below). The measurement step size
                      was in 2 mm increments at a distance of 10 mm between the surface of the
                      wireless device as shown below:
                                                                                                                        T-Coil Probe



                                                                                                                        T-coil Element
                                                                 10 mm




                                                                                                 Wireless Device

                                                                                          Figure 5-11
                                                                                      Measurement Distance
.
                          ii. After scanning, the planar field maximum point was determined. The position of
                              the probe was moved to this location to setup the test using the sound check
                              system.
                         iii. These steps were repeated for the other T-coil orientations (of axial, radial
                              transverse, or radial longitudinal) per Figure 5-16 after a T-coil orientation was
                              fully measured with the sound check system.


                                                                                                                                                                Reviewed by:
FCC ID: ZNFUN160                                                               HAC (T-COIL) TEST REPORT
                                                                                                                                                                Quality Manager
Filename:                   Test Dates:                                           EUT Type:
                                                                                                                                                                Page 13 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                                 Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                                                            REV 6.4C
                                                                                                                                                                       04/05/10


               b. Speech Signal Setup to Base Station Simulator
                      i. C63.19 Table 6-1 states audio reference input levels for various technologies:

                                                                                                     Input Level
                                              Standard                    Technology
                                                                                                       (dBm0)
                                          TIA/EIA/IS-2000            CDMA                                -18
                                          J-STD-007                  GSM (217 Hz)                        -16
                                          T1/T1P1/3GPP               UMTS (WCDMA)                        -16
                                          iDENTM                     TDMA (22 and 11 Hz)                 -18

                              The CMU200 audio levels were determined using base station simulator
                              manufacturer calibration procedures resulting in the below corresponding
                              voltages relative to handset test point level (in dBm0):

                                                                      Table 5-3
                                                         CMU200 Voltage Input Levels for Audio
                                          dBm0 Ref.              Input Voltage            Notes

                                                                                          From CDMA2K "DECODER CAL".
                                          3.14 dBm0      1052.0 mV              0.4 dBV   (What is needed through Encoder
                                                                                          for FS)
                                           -18 dBm0      92.260 mV          -20.7 dBV     For 8k Enhanced (Low)


               c. Real-Time Analyzer (RTA)
                      i. The Real-Time Analyzer was configured to analyze measurements using 1/3
                         Octave band weighted filtering.
               d. WD Radio Configuration Selection
                      i. The device was chosen to be tested in the worst-case ABM2 condition under
                         RC1/SO3 (EVRC) (see below):




                                                     Figure 5-12
                                            Vocoder Analysis for ABM Noise

     4. Signal Quality Data Analysis
            a. Narrow-band Magnetic Intensity
                     i. The standard specifies a 1 kHz 1/3 octave band minimum field intensity for a sine
                        tone. The ABM1 measurements were evaluated at 1kHz with 1/3 octave band
                        filtering over an averaged period of 10 seconds.
            b. Frequency Response
                     i. The appropriate frequency response curve was measured to curves in Figure 4-1
                        or Figure 4-2 between 300 – 3000 Hz using digital linear averaging (limit lines

                                                                                                                   Reviewed by:
FCC ID: ZNFUN160                                            HAC (T-COIL) TEST REPORT
                                                                                                                   Quality Manager
Filename:                   Test Dates:                      EUT Type:
                                                                                                                   Page 14 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012            Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                  REV 6.4C
                                                                                                                             04/05/10


                             chosen according to measurement found in step 4a.) A linear average over 3x
                             the length of the artificial voice signal (3x sampling) was performed. A 10 second
                             delay was configured in the measurement process of the stimulus to ensure
                             handset vocoder latency effects and echo cancellation devices (if any) were
                             appropriately stabilized during measurements.
                         ii. The appropriate post-processing was applied according to the system processing
                             chain illustrated in Figure 5-13. All R10 frequencies were plotted with respect to
                             0dB at 1 kHz value and aligned with respect to the EIA-504 mask.


                                                            Probe                           40 dB     Full-Band             Subtract P.50        Frequency
     P.50                                 40
                      WD                                   Sensitivity                     pre-gain   Integrator               stimulus         Response of
   stimulus                               dB                                                factor      curve
                                                           (-59.09 dBV/A/m)                                                  frequency            the WD
                                                                                                                              character


                                 Figure 5-13 Frequency Response Block Diagram

                         iii. The margin is represented by the closest measured data point on the curve to
                              the EIA-504 limit lines, in dB.

               c.   Signal Quality Index
                          i. Ensuring the WD was at maximum RF power, maximum volume, backlight on,
                             display on, maximum contrast setting, keypad lights on (when possible) with no
                             audio signal through the vocoder, the WD was measured over at least 100 Hz –
                             10,000 Hz, maximized over 5 seconds with a 50ms sample time for the ABM2
                             measurement (5 second time period is used in noise measurements under
                             standards such as IEEE 269, etc.)
                         ii. After applying half-band integration and A-weighting to the result, a power sum
                             was applied over each 1/3 octave bandwidth frequency for an ABM2 value
                        iii. This result was subtracted from the ABM1 result in step a, to obtain the Signal
                             Quality.

V.       Test Setup

                                                                                                          Integrator



                                                                                                      1/3 Octave Bandpass
                                                                                                            Filter
                                                                 Probe Coil
                                                               (Shown in Axial Position)

                                                                                                      RMS Voltmeter



                                                        Wireless Device                                   Graphics
                                                                                                          Recorder



                                                                            Reference
                                                                                                           Signal
                                                                           Base Station
                                           Antenna replaced                                                Source
                                                                            Simulator
                                           with Coaxial Connection




                                                                                                        Controller

                                                        Figure 5-14
                                               Audio Magnetic Field Test Setup

VI.      Deviation from C63.19 Test Procedure

Non-conducted RF connection.

                                                                                                                                            Reviewed by:
FCC ID: ZNFUN160                                                          HAC (T-COIL) TEST REPORT
                                                                                                                                            Quality Manager
Filename:                   Test Dates:                                     EUT Type:
                                                                                                                                            Page 15 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                           Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                                        REV 6.4C
                                                                                                                                                   04/05/10


VII. Wireless Device Channels and Frequencies

The frequencies listed in the table below are those that lie in the center of the bands used for cellular
telephony. Low, middle and high channels were tested in each band for FCC compliance evaluation to
ensure the maximum emission is captured across the entire band.

To facilitate setting of a base station simulator for ABM measurements, specific band plan channel
numbers are listed that may be used in lieu of the band center frequencies.

                                                     Table 5-4
                                          Center Channels and Frequencies
                                      Test frequencies & associated channels
                                                                                  Frequency
                                             Channel
                                                                                    (MHz)
                                                    Cellular 850
                                           384 (CDMA)                              836.52
                                                       PCS 1900
                                           600 (CDMA)                               1880
                                                       AWS 1750
                                           450 (CDMA)                              1732.50

VIII. RF Emission Effect on T-coil Measurements




                                          Figure 5-15
    High power RF Emissions Effect with HAC Dipole on the T-coil Probe System 10mm between
                             dipole maximum and magnetic probe




                                                                                                Reviewed by:
FCC ID: ZNFUN160                                       HAC (T-COIL) TEST REPORT
                                                                                                Quality Manager
Filename:                   Test Dates:                 EUT Type:
                                                                                                Page 16 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012       Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                            REV 6.4C
                                                                                                       04/05/10


IX.     Test Flow
The flow diagram below was followed (From C63.19):

                                   ♦ Confirm calibration of test
                                     equipment
                                   ♦ Configure and validate test
                                     setup
                                   ♦ Establish WD reference level
                                   ♦ Scan for measurement locations




                                   ♦ Position and orient probe
                                   ♦ Measure desired audio band
                                     Signal strength
                                   ♦ Measure undesired audio
                                     Band signal strength



                                   ♦ Calculate signal strength
                                   ♦ Calculate signal quality
                                   ♦ Measure frequency response




                                            All 3 locations
                                             measured?
                                                                        N

                                                       Y



                                             Intensity and
                                          Frequency response             N
                                              compliant?




                                                       Y


                                     Determine and record signal                   Done
                                          Quality category




                                                    Figure 5-16
                                          C63.19 T-Coil Signal Test Process
                                                                                          Reviewed by:
FCC ID: ZNFUN160                                        HAC (T-COIL) TEST REPORT
                                                                                          Quality Manager
Filename:                   Test Dates:                    EUT Type:
                                                                                          Page 17 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012          Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                      REV 6.4C
                                                                                                 04/05/10


6.          TEST SUMMARY

I.       T-Coil Test Summary
                                                                Table 6-1
                                                             Table of Results
                                                                                              Minimum
             C63.19 Sec.      Mode          Band                   Test Description                              Measured     Verdict
                                                                                               Limit*
                                                                                                dBA/m             dBA/m      PASS/FAIL
               7.3.1.1                                Intensity, Axial                             -18             -4.5        PASS
               7.3.1.2                                Intensity, RadialH                           -18            -13.3        PASS
               7.3.1.2                                Intensity, RadialV                           -18            -14.4        PASS
                7.3.3         CDMA        Cellular    Signal-to-Noise/Noise, Axial                 20              51.7        PASS
                7.3.3                                 Signal-to-Noise/Noise, RadialH               20              45.3        PASS
                7.3.3                                 Signal-to-Noise/Noise, RadialV               20              36.8        PASS
                7.3.2                                 Frequency Response, Axial                    0               1.8         PASS


               7.3.1.1                                Intensity, Axial                             -18             -5.4        PASS
               7.3.1.2                                Intensity, RadialH                           -18            -13.3        PASS
               7.3.1.2                                Intensity, RadialV                           -18            -14.1        PASS
                7.3.3         CDMA          PCS       Signal-to-Noise/Noise, Axial                 20              50.5        PASS
                7.3.3                                 Signal-to-Noise/Noise, RadialH               20              45.9        PASS
                7.3.3                                 Signal-to-Noise/Noise, RadialV               20              36.1        PASS
                7.3.2                                 Frequency Response, Axial                    0               1.8         PASS


               7.3.1.1                                Intensity, Axial                             -18             -4.5        PASS
               7.3.1.2                                Intensity, RadialH                           -18            -13.0        PASS
               7.3.1.2                                Intensity, RadialV                           -18            -14.0        PASS
                7.3.3         CDMA          AWS       Signal-to-Noise/Noise, Axial                 20              52.4        PASS
                7.3.3                                 Signal-to-Noise/Noise, RadialH               20              45.3        PASS
                7.3.3                                 Signal-to-Noise/Noise, RadialV               20              37.7        PASS
                7.3.2                                 Frequency Response, Axial                    0               1.8         PASS


Note: The above summary table represents the worst-case numerical values according to configurations in Table 6-3.

                                                              Table 6-2
                                                     Consolidated Tabled Results
                              Volume                    Cellular                         AWS                                   PCS
                              Setting
                                             Axial      RadialH       RadialV    Axial   RadialH       RadialV       Axial    RadialH    RadialV
      Freq. Response Margin                  PASS        PASS         PASS       PASS    PASS            PASS       PASS       PASS       PASS
     Magnetic Intensity Verdict Maximum      PASS        PASS         PASS       PASS    PASS            PASS       PASS       PASS       PASS
            FCC SNR Verdict                  PASS        PASS         PASS       PASS    PASS            PASS       PASS       PASS       PASS


Note: The above table represents the pass/fail verdict according to data in Table 6-3.

                                                                                                                                 Reviewed by:
FCC ID: ZNFUN160                                                   HAC (T-COIL) TEST REPORT
                                                                                                                                 Quality Manager
Filename:                     Test Dates:                           EUT Type:
                                                                                                                                 Page 18 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                   Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                               REV 6.4C
                                                                                                                                          04/05/10


II.      Raw Handset Data
                                                           Table 6-3
                                                        Raw Data Results
                                                                                      Cellular Band
                                Volume
                                                        Axial                           RadialH                        RadialV
                                               1013      384         777      1013       384        777        1013     384         777
                ABM1, dBA/m                    -4.37    -3.99       -4.46    -13.27     -12.69     -12.95     -13.26   -13.44      -14.35
                ABM2, dBA/m                   -56.41   -56.87      -56.17    -58.55     -58.85     -58.83     -51.30   -51.92      -51.13
        Ambient Noise, dBA/m                  -60.36   -60.36      -60.36    -61.44     -61.44     -61.44     -60.80   -60.80      -60.80
       Freq. Response Margin
                                              1.88      2.00        1.80      1.88        1.76        1.86    2.00      1.93        1.88
                         (dB) Maximum
                  S+N/N (dB)                  52.04    52.88        51.71     45.28      46.16        45.88   38.04    38.48       36.78
        S+N/N per orientation
                                                       51.71                             45.28                         36.78
                        (dB)

                                                                                       PCS Band
                                Volume
                                                        Axial                           RadialH                        RadialV
                                                25       600        1175       25        600        1175        25      600         1175
                ABM1, dBA/m                    -4.33    -5.39       -4.73    -12.71     -13.07     -13.27     -13.37   -13.53      -14.08
                ABM2, dBA/m                   -55.06   -56.33      -55.19    -58.59     -58.93     -59.42     -50.28   -51.37      -50.19
        Ambient Noise, dBA/m                  -60.36   -60.36      -60.36    -61.44     -61.44     -61.44     -60.80   -60.80      -60.80
       Freq. Response Margin
                                              1.94      2.00        1.84      1.79        1.97        1.76    2.00      1.96        1.96
                         (dB) Maximum
                  S+N/N (dB)                  50.73    50.94        50.46     45.88      45.86        46.15   36.91    37.84       36.11
        S+N/N per orientation
                                                       50.46                             45.86                         36.11
                        (dB)

                                                                                       AWS Band
                                Volume
                                                        Axial                           RadialH                        RadialV
                                                25       450         875       25        450        875         25      450         875
              ABM1, dBA/m                      -4.24    -4.51       -4.16    -13.03     -12.83     -12.83     -14.04   -13.24      -14.04
              ABM2, dBA/m                     -56.59   -57.69      -56.85    -58.33     -58.98     -59.19     -51.73   -53.74      -53.16
       Ambient Noise, dBA/m                   -60.36   -60.36      -60.36    -61.44     -61.44     -61.44     -60.80   -60.80      -60.80
       Freq. Response Margin
                               Maximum        1.98      1.99        1.84      1.99        1.70        2.00    1.77      1.85        1.91
                         (dB)
                  S+N/N (dB)                  52.35    53.18        52.69     45.30      46.15        46.36   37.69    40.50       39.12
         S+N/N per orientation
                                                       52.35                              45.3                         37.69
                         (dB)
                                 [x,y] from
      T-coil Coordinates (cm)                          2.9,2.6                           2.7,3.1                       3.2,2.7
                                bottom left



Note: ABM1 >> Ambient noise

WD Configuration

      1. Radio Configuration: RC1/SO3 (EVRC)
      2. Power Configuration: Power Control Bits = "All Up"
      3. Phone Condition: Mute on; Backlight on; Max Volume, Max Contrast


                                                                                                                               Reviewed by:
FCC ID: ZNFUN160                                            HAC (T-COIL) TEST REPORT
                                                                                                                               Quality Manager
Filename:                   Test Dates:                          EUT Type:
                                                                                                                               Page 19 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                           REV 6.4C
                                                                                                                                      04/05/10


III.    Frequency Response Graph




                                                                                                     Figure 6-1
                                                                                            Axial Frequency Response

Note: This frequency response represents the worst-case ABM2 test configuration according to Table
6-3.

IV.     1 kHz Vocoder Application Check

                                                                                             CDMA2000 Pure Tone suppression characterization (example)

                                                                              30


                                                                              20


                                                                              10
                                    Magnetic Intensity at 1kHz, R10 (dBA/m)




                                                                               0


                                                                              -10


                                                                              -20


                                                                              -30


                                                                              -40


                                                                              -50


                                                                              -60


                                                                              -70
                                                                                -50   -45    -40       -35      -30         -25         -20   -15        -10   -5   0
                                                                                                                  Audio input level (dBm0)




This model was verified to be within the linear region for ABM1 measurements. This measurement was
taken in the axial configuration above the ABM1 maximum location/configuration derived from Table 6-3.

V.      Undesirable Audio Magnetic Band Plot (ABM2)




                                                                                                 Figure 6-2
                                                                                        Worst-case ABM2 Plot for WD


                                                                                                                                                                        Reviewed by:
FCC ID: ZNFUN160                                                                                             HAC (T-COIL) TEST REPORT
                                                                                                                                                                        Quality Manager
Filename:                   Test Dates:                                                                        EUT Type:
                                                                                                                                                                        Page 20 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012                                                              Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                                                                    REV 6.4C
                                                                                                                                                                               04/05/10


Note: This plot represents the data from the location/configuration resulting in the highest ABM2 result
shown in Table 6-3.

VI.     T-Coil Validation Test Results




                                                   Figure 6-3
                               Helmholtz Coil Validation for Frequency Response



                                                     Table 6-4
                                     Helmholtz Coil Validation Table of Results

                       Item                             Target                 Result        Verdict

 Signal Validation
 Frequency Response, from limits                      0 ± 0.5 dB                0.30         PASS
 Magnetic Intensity, -10 dBA/m                       -10 ± 0.5 dB              -9.503        PASS
 Noise Validation

 Axial Environmental Noise                          < - 58 dBA/m               -60.36        PASS

 RadialH Environmental Noise                        < - 58 dBA/m               -61.44        PASS

 RadialV Environmental Noise                        < - 58 dBA/m               -60.80        PASS




                                                                                               Reviewed by:
FCC ID: ZNFUN160                                    HAC (T-COIL) TEST REPORT
                                                                                               Quality Manager
Filename:                   Test Dates:              EUT Type:
                                                                                               Page 21 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012    Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                           REV 6.4C
                                                                                                      04/05/10


7.          FCC 3G MEASUREMENTS

Radio Configuration 1, Service Option 3 (thick, green data curve) was used for the testing as the worst-
case configuration for the handset due to vocoder gating from the EVRC logic. See below plot for ABM
noise comparison between operational field service options and radio configurations for a CDMA2000
handset:




                                                     Figure 7-1
                                          CDMA2000 Audio Band Magnetic Noise

I.       ABM Measurements
                        ABM1 Pre-Test (dBA/m)


                          RC1/SO3          RC3/SO3       RC4/SO3              Orientation           Channel


                           -13.200          -13.620       -13.440                  radialV         PCS 1175


                        ABM2 Pre-Test (dBA/m), A, HBI
                         RC1/SO3 RC3/SO3       RC4/SO3                        Orientation           Channel
                            -50.22           -59.96        -59.71                  radialV         PCS 1175

           Mute on; Backlight on; Max Volume, Max Contrast
           Power Control Bits = "All Up"

                                                                      Probe                   40 dB
                                                    40
                       WD noise                                      Sensitivity             pre-gain         curve
                                                    dB
                                                                    (-59.09 dBV/A/m)          factor


                                                Figure 7-2
                           Audio Band Magnetic Curve Measurement Block Diagram




                                                                                                                      Reviewed by:
FCC ID: ZNFUN160                                         HAC (T-COIL) TEST REPORT
                                                                                                                      Quality Manager
Filename:                   Test Dates:                   EUT Type:
                                                                                                                      Page 22 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012         Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                  REV 6.4C
                                                                                                                             04/05/10


8.          MEASUREMENT UNCERTAINTY

                                                         Table 8-1
                                                Uncertainty Estimation Table
                                                                                                                      Standard
                                     Data +/- Data +/-                          Probability               Standard
              Contribution                                   Data Type                         Divisor               Uncertainty
                                       %        dB                              distribution             uncertainty
                                                                                                                        (dB)
  ABM Noise                            7.0%      0.29        Std. Dev.          Normal k=1      1.00        7.0%
  RF Reflections                       4.7%      0.20       Specification       Rectangular     1.73        2.7%
  Reference Signal Level              12.2%      0.50       Specification       Rectangular     1.73        7.0%
  Positioning Accuracy                10.0%      0.41       Uncertainty         Rectangular     1.73        5.8%
  Probe Coil Sensitivity              12.2%      0.50       Specification       Rectangular     1.73        7.0%
  Probe Linearity                      2.4%      0.10        Std. Dev.          Normal k=1      1.00        2.4%
  Cable Loss                           2.8%      0.12       Specification       Rectangular     1.73        1.6%
  Frequency Analyzer                   5.0%      0.21       Specification       Rectangular     1.73        2.9%
  System Repeatability                 5.0%      0.21        Std. Dev.          Normal k=1      1.00        5.0%
  WD Repeatability                     9.0%      0.37        Std. Dev.          Normal k=1      1.00        9.0%
  Positioner Accuracy                  1.0%      0.04       Specification       Rectangular     1.73        0.6%

  Combined standard uncertainty, uc (k=1)                                                                  17.7%         0.71
  Expanded uncertainty (k=2), 95% confidence level                                                        35.3%          1.31
             Notes:
            1. Test equipments are calibrated according to techniques outlined in NIS81, NIS3003 and NIST Tech Note 1297.
            2. All equipments have traceability according to NIST. Measurement Uncertainties are defined in further detail in
                NIS 81 and NIST Tech Note 1297 and UKAS M3003.

Measurement uncertainty reflects the quality and accuracy of a measured result as compared to the true
value. Such statements are generally required when stating results of measurements so that it is clear to
the intended audience that the results may differ when reproduced by different facilities. Measurement
results vary due to the measurement uncertainty of the instrumentation, measurement technique, and test
engineer. Most uncertainties are calculated using the tolerances of the instrumentation used in the
measurement, the measurement setup variability, and the technique used in performing the test. While
not generally included, the variability of the equipment under test also figures into the overall
measurement uncertainty. Another component of the overall uncertainty is based on the variability of
repeated measurements (so-called Type A uncertainty). This may mean that the Hearing Aid
compatibility tests may have to be repeated by taking down the test setup and resetting it up so that there
are a statistically significant number of repeat measurements to identify the measurement uncertainty. By
combining the repeat measurement results with that of the instrumentation chain using the technique
contained in NIS 81 and NIS 3003, the overall measurement uncertainty was estimated.




                                                                                                                     Reviewed by:
FCC ID: ZNFUN160                                           HAC (T-COIL) TEST REPORT
                                                                                                                     Quality Manager
Filename:                     Test Dates:                    EUT Type:
                                                                                                                     Page 23 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012            Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                 REV 6.4C
                                                                                                                            04/05/10


9.          EQUIPMENT LIST

                                                           Table 9-1
                                                         Equipment List
   Manufacturer           Model                       Description                Cal Date     Cal Interval    Cal Due     Serial Number

      Agilent            E5515C             Wireless Communications Test Set     2/14/2012      Annual       2/14/2013     GB43304447
      Agilent            E4407B                  ESA Spectrum Analyzer            4/3/2012      Annual        4/3/2013     US39210313
      Agilent            E5515C             Wireless Communications Tester        4/4/2012      Annual        4/4/2013     US41140256
 Control Company        36934-158             Wall-Mounted Thermometer            1/4/2012      Biennial      1/4/2014      122014497
   Gigatronics           80701A                (0.05-18GHz) Power Sensor         10/10/2012     Annual       10/10/2013      1833460
   Gigatronics            8651A                  Universal Power Meter           10/10/2012     Annual       10/10/2013      8650319
      Listen          SoundConnect              Microphone Power Supply          4/26/2012      Annual       4/26/2013     0899-PS150
      Listen           SoundCheck               Acoustic Analyzer System         10/4/2012      Annual       10/4/2013        979921
        NI                 4474                   Data Acquisition Card              N/A                         N/A           N/A
 Rohde & Schwarz         CMU200                   Base Station Simulator         5/22/2012      Annual       5/22/2013        109892
     Seekonk              NC-100                  Torque Wrench (8" lb)          11/29/2011    Triennial     11/29/2014       21053
       TEM          Radial T-Coil Probe            Radial T-Coil Probe            1/20/2012     Annual        1/20/2013     TEM-1130
       TEM          Axial T-Coil Probe              Axial T-Coil Probe            1/20/2012     Annual        1/20/2013     TEM-1124
       TEM          Radial T-Coil Probe            Radial T-Coil Probe            3/14/2012     Annual        3/14/2013     TEM-1133
       TEM            Helmholtz Coil                  Helmholtz Coil              4/27/2012     Annual        4/27/2013      SBI 1052
       TEM                C63.19                      Helmholtz Coil             11/11/2011    Biennial      11/11/2013         925
       TEM                                 HAC System Controller with Software       N/A                         N/A           N/A
       TEM                                           HAC Positioner                  N/A                         N/A           N/A




                                                                                                                          Reviewed by:
FCC ID: ZNFUN160                                           HAC (T-COIL) TEST REPORT
                                                                                                                          Quality Manager
Filename:                    Test Dates:                     EUT Type:
                                                                                                                          Page 24 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012            Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                                                      REV 6.4C
                                                                                                                                 04/05/10


@uc


             West Caldwell Calibration Laboratories Inc.




      Certificate of Calibration
                                                               for

                                              Axial T Coil Probe
                                    Manufactured by:           TEM CONSULTING
                                    Model No:                          Axial T Coil Probe
                                    Serial No:                         TEM—1124
                                    Calibration Recall No:             21559
                                                          Submitted By:

                                    Customer:            _    STEVELIU
                                    Company:                   PCTEST ENGINEERING LAB
                                    Address:                   6660—B DOBBIN ROAD
                                                               COLUMBIA              MD 21045


  The subject instrument was calibrated to the indieated specification using standards traceable to the
  National Institute of Standards and Technology or to accepted values of natural physical constants.
  This document certifics that theinstrument met the following specification uponits return to the
  submitter.

  West Caldwell Calibration Laboratories Procedure No.                      Axial T Col TEM
  Upon receipt for Calibration, the instrument was found to be:

                    Within         (X )        see attached Report of Calibration,

  the tolerance of the indieated speeification,

  West Caldwell Calibration Laboratories‘ calibration control system meets the requirements, ISO
  10012—1 MIL—STD—45662A, ANSUNCSL Z540—1, IEC Guide 26, ISO 9001:2008 and ISO 17025.




  Note: With this Cartiicate, Report of Callbration is included.                 Approved by:
                                                    \/
  Calibration
    alibration Date:
                 Date            20—Jan—12
                                     an                      [/12/[7
                                                                / i2                           t


  Certificate No:                21559 +1                                        Felix Christopher
                                                                                 Qually Manager
  QA Do #1081 Rev.£.0 10/tO1                      Certificate Page 1 of 1

                               West Caldwell                                   150com—ams
                               Calibration                                     Winmniedinini
                                                                                  io Tussate
uncompromised calibration       Laboratories, Inc.                             uksn
1576 State Route 98, Vietor, NY 14584, U..A.                                   Phone: (685) §86—3000 Fax.: (585) 586—4827


                                                         HCATEMC_TEM—1124_Jan—20—2012


                                                                                                                                                     AccnEpIATION
                                      West Caldwell                                                                                                   isonc 17025
                                       Calibration
  uncompromised           calibration   Laboratories, Inc.
1575 State Route 96, Victor NY 14564                                                                                                                     15330



                                           REPORT OF CALIBRATION
           TEM Consulting LP Axial T Coll Probe                                    Model No.: AxialT Coil Probe                         Serlal No.: TEM—1124

  Company : Petest Engineering Lab.                                                                                                         1. D. No: 80578
[Calibration results:                                                                                Before data: .........              After data: .........
                    Probe Sensitivity measured with Helmholtz Coll
                                       Helmholtz Coll:                                                                 Before & after data same: ...X......
                  the number of turns on eachcoil;                 10          No.
                  the radius of each coil, in meters;            0.204         m                                   Laboratory Environment
              the current in the coils, in amperes.;              0.08         A                              Amblent Temperature:          224          *o
                           Helmholtz Coll Constant;               6.98         Aim/V                              Ambient Humidity          30.8         % RH
                     Helmholtz Coll magnetic field;               5.90         Alm                                Amblent Pressure:        100.1         kPa
                                                                                                                   Callbration Date:    20—Jan—12.       1:01 PM
                               Probe Sensitivity at               1000         Hz.                               Re—calibration Due:    20—Jan—13
                                              was                —60.16        dBV/AIm                               Report Number:       21559          41
                                                                 0.981         mViAim                               Control Numbar:       21558
                                   Probe resistance               904          Ohms
The above listed instrument meets or exceeds the tested manufacturer‘s specifications.
(This Callbration is traceable through NIST test numbers:                      205342
[The expandad uncortainly of callbration: 0.30dB at 95% confidence lovel with a coveragefactor of k=2.
Graph represents Probes Frequency Response.
                                                                              Axtal Probe Response                            _
      20 qe                                            rmpevandietn B                  m                                [_—i—Measured Probe..          s

      15                                                                                                                               // e

                                                                                                                 // —|
  & "s                _
  &
  §&3 o                                                                              in
  §                                                                       &11
  8



                                                                         Freq.(Hz)        1000                                                                       10000

The abovelisted instrument was checked using calibration procedure documented in West Caldwell
Calibration Laboratories Inc. procedure :                                                   Rev. 5.0 Sept. 10, 2010 Doc. # 1038 HCATEMC
Calibration was performed by West Caldwell Calibration Laboralories Inc. under Operating Procedures
intended to implement the requirements of IS010012—1, IEC Guide 25, ANSINCSL 2540—1, (MIL—STD—45862A) and 180 9001:2008, ISO 17026

                          Cal. Date:       20—Jan—2012          1:01 PM                                  Measurements performed by:
Callbrated on WCCL system type 9700                                                                                                    Folix Christopher
This document shallnot be reprodued, excepin ful, wthout tho wilten approval romWest CatdwollGat. Ltos. Ic.                Rev. 8Sopt. 10, 2010 D.    1038 HCATENC




                                                                                Page 1 of 2



                                  £) RCTest
                                                                                                                                         @uc


                                                           HCATEMC_TEM—1124_Jan—20—2012

                                         West Caldwell Calibration Laboratories Inc.
                                                                  1875 State Route 96, Victor NY 14664
                                                                Tol. (585) 586—3900 FAX (685) 686—4327
                                                     Calibration Data Record
                                                                                        for
         TEM Consulting LP Axial T Coil Probe                                        Model No.: Axial T Coll Probe                        Serial No.: TEM—1124
                                                                                    Company : Potest Engineering Lab.

Test                Function                                                             Tolerance                                  Measured values
                                                                                                                           Before             Out            Romarks

1.0                 Probe Sensitivity at                                  1000 Hz.                    dBViAIm              —60.16

                                                                                                                 dB
2.0                 Probe Level Linearity                                                                        6          6.03
                                                                                  Ref. (0 dB)                    0          0.00
                                                                                                                 —8        —6.02
                                                                                                                 12        12.03

                                                                                                                 Hz
3.0                 Probe Frequency Response                                                                     100       419.9
                                                                                                                 126       17.9
                                                                                                                 158       +15.9
                                                                                                                 200       413.9
                                                                                                                 251       11.9
                                                                                                                 316       +10.0
                                                                                                                 398        —8.0
                                                                                                                 §01        —6.0
                                                                                                                 631        40
                                                                                                                 794        —2.0
                                                                                  Rof. (0 4B)                1000           0.0
                                                                                                             1259           2.0
                                                                                                             1585           4.0
                                                                                                             1995           6.0
                                                                                                             2512           79
                                                                                                             3162           9.9
                                                                                                             3981           11.9
                                                                                                             5012           13.9
                                                                                                             6310           15.
                                                                                                             7943           18.0
                                                                                                             10000          20.2




instruments used for callbration:                                                                           Date of Cal.                Traceabilty No.           us Date
          P                                      34401A                     s Usssos4                       17—0ct—2011                 205342                 16—0ct—2012
          HP                                     34401A                     S/N. US361024                   17—0ct—2011                 205342                 16—Oct—2012
          HP                                     33120A                     SMN. S3604371                   17—0ct—2011                 206342                 16—0ct—2012
         B&K                                         2133                   SIN 1492410                      4—Nov—2011                 68128041141             4—Nov—2012




                          Cal. Date:          20—Jan—2042         1:01 PM                                                  Tested by: Felix Christopher
Callbrated on WCCL system type 9700
This documont shatlnot be reproducad, oxcept in ful, wihout the wrtten approval eom West Galdwell Gat.Labs.Inc               Rew. 80 Sept. 10 2410 Doc. 1038 HCATENC




                                                                                   Page 2 of 2



                                   £) RCTest                                                                                               @uc


             West Caldwell Calibration Laboratories Inc.




      Certificate of Calibration
                                                            for

                                             Radial T Coil Probe
                                    Manufactured by:          TEM CONSULTING
                                     Model No:                         Radial T Coll Probe
                                     Serial No:                        TEM—1130
                                     Calibration Recall No:            21559
                                                       Submitted By:
                                     Customer:              STEVE LIU
                                     Company:               PCTEST ENGINEERING LAB
                                     Address:               6660—B DOBBIN ROAD
                                                            COLUMBIA              MD 21045


  The subject instrument was calibrated to the indicated specification using standards traceable to the
  National Institute of Standards and Technology or to aecepted values of natural physical constants.
  This document certifies that the instrument met the following specification upon its returnto the
  submitter.

  West Caldwell Calibration Laboratories Procedure No.                      Radial T C TEM
  Upon reeeipt for Calibration, the instrument was foundto be:

                    Within         CX )         see attached Report of Calibration,

  the tolerance of the indicated specification.

  West Caldwell Calibration Laboratories‘ ealibration control system meets therequirements, ISO
  10012—1 MIL—STD—45662A, ANSI/NCSL Z540—1, IEC Guide 25, ISO 9001:2008 and ISO 17025.




  Note: With this Certifcate, Report of Calibration is included.                 Approved by:
                                                   P
  Calibration Date:              20—Jan—12                         I                         ts
  Certificate No:                21559 +2                                        Felix Christopher
  O Boe.1081 Rev. 2.0 1001                        Certificate Page 1 of 1        Quality Manager

                             West Caldwell                                     Egz:fl:m
                                                                                 4     yog:
                             Calibration                                      Cntatestimas
uncompromised catbraton        Laboratories, Inc.                             ruist
1575 State Roule 96, Victor, NY 14564, U.S.A.                                 Phone: (685) 586—3900 Fax.: (§8) 586—4327




                                                                                                          @uc


                                                          HCRTEMC_TEM—1130_Jan—20—2012


                                                                                                                                                          AcchEDITATON
                                       West Caldwell                                                                                                       isorec 025


  uncompromised calibration
1875 State Route 96, Victor NY 14564
                                        Calibration
                                             Laboratories, Inc.                                                                                            «a1632.01



                                             REPORT OF CALIBRATION
                                                                                         for
            TEM Consulting LP Radial T Coil Probe                                    Model No.: Radial T Coil Probe                           Serial No.: TEM~1130
  Company : Potest Engineering Lab.                                                                                                               1. D. No: 80578
Calibration results:                                                                                    Before data .........                  After data: .........
                   Probe Sensitivity measured with Helmholtz Coil
                                        Helmholtz Coil;                                                                   Before & afterdata same: ... X......
                    the number ofturns on each coil;                 10          No.
                    the radius of each coil, in meters;           0.204          m                                    Laboratory Environment:
                  the current in the coils, in amperes.;           0.08          A                               Amblent Temperature:             224         o
                             Helmholtz Coll Constant;              6.98          AlmIV                               Amblant Humidity:            30.8        % RH
                       Helmholtz Coil magnetic field;              5.90          Alm                                Amblent Prossure:             100.1       kPa
                                                                                                                      Calibration Date:       20—Jan—12        1:30 PM
                                Probe Sensitivity at               1000          Hz.                                Re—callbration Due:       20—Jan—13
                                                      was         —$0.50         dBV/AIm                               Report Number              21559       —2
                                                                   0.944         mViAim                                Control Number:            21559
                                    Probe resistance                803          Ohms
The above listed instrument meets or exceeds the tested manufacturer‘s specifications.
(This Calibration is traceable through NIST test numbers:                           205342
[The expanded uncertainty of calibration: 0.30dB al 95% contidence level with a coverage factor of k=2.
GI’EEH reglesel\l.s Probes Freg uency RDSE onse.

                                                                               Radial Probe Response                                          —
      zs                                                                                            ®       e              [ —i—Measured Probo Resp.

      15     4—                                                      *~
                                                                                |t                                                            L7k7
                                                                                                                                                                 A]    C1
      10 {—                                                                                                                     La——
  @ s
  &
  8
  3 0
  &
  § s {——                                                                                                                                 &
  =
      10                                                                                                                                                               5

      —16    /
      20                                                               send                                                                                  —
            100                                                            Froq. (Hz)       1000                                                                         10000
The above listed instrument was checked using calibration procedure documented in West Caldwell
Calibration Laboratories Inc. procedure :                                                   Rev. 5.0 Sept, 10, 2010 Doc. # 1038 HCRTEMC
Callbration was performed by West Caldwell Calibration Laborataries Inc. under Oparaling Procedures
intended to implement the requirements of 15010012—1, IEG Guide 25, ANSNNCSL 2540—1, (MIL—STD—45662A) and ISO 9001:2008, ISP

                   Cal. Date: 20—Jan—2012                         1:30 PM                                   Measurements performad by: .
                                                                                                                                                    //Z,/ 17025


Calibrated on WCCL system type 9700                                                                                                       Felix Chri stopher
This documont shalfnot be reproduced, except in ful, wihout the written approval romWest Caldwall Ga. Labs. e                Row. 60 Sopt 10, 2010 bos. # 1038 HCRTENC


                                                                                     Page 1 of 2



                                   £) RCTest
                                                                                                                                              @uc


                                                           HCRTEMC_TEM—1130_Jan—20—2012

                                         West Caldwell Calibration Laboratories Inc.
                                                                 1575 Stato Route 96, Victor NY 14564
                                                               Tel. (585) 586—3900 FAX (685) 586—4327

                                                    Calibration Data Record
                                                                                         for
         TEM Consulting LP Radial T Coll Probe                                      Model No.: Radial T Goil Probe                        Serial No.: TEM—1130
                                                                                   Company : Potest Engineering Lab.

Test               Function                                                             Tolerance                                   Measured values
                                                                                                                          Before              Out              Remarks

1.0                Probe Sensitivity at                                  1000 Hz.                    dBV/Aim              —80.50

                                                                                                                dB
2.0                Probe Level Linearity                                                                         6         6.03
                                                                                 Ref. (0 dB)                    0          0.00
                                                                                                                —6         .02
                                                                                                                12        ~12.02

                                                                                                                Hz
3.0                Probe Frequency Response                                                                     100       20.0
                                                                                                                126       18.0
                                                                                                                158       415.9
                                                                                                                200       413.9
                                                                                                                251       41.9
                                                                                                                316       +10.0
                                                                                                                308        —8.0
                                                                                                                501        —6.0
                                                                                                                631        —4.0
                                                                                                                794        —2.0
                                                                                 Ref. (0 dB)                1000           0.0
                                                                                                            1259           2.0
                                                                                                            1505           4.0
                                                                                                            1995           6.0
                                                                                                            2512           T.9
                                                                                                            3162           9.9
                                                                                                            3981           11.9
                                                                                                            5012           13.9
                                                                                                            6310           15.9
                                                                                                            7943           18.0
                                                                                                            10000          20.1




Instruments used for callbration:                                                                          Dato of Cal.                 Traceability No.            Due Date
                                                 34401A                    SIN US360641                    17—0ct—2011                  205342                   16—0ct—2012
          HP                                     34401A                    S US361024                      17—0ct—2011                  205342                   16—0ct—2012
          HP                                     so120A                    Sm soso4ar1                     17—Ont—2011                  205342                   16—0ct—2012
         B8K                                          2133                 SN 1492410                       4—Nov—2011                  681/280411—11             4—Nov—2012



                          Cal. Date:         20—Jan—2012          1:30 PM                                                 Tested by: Felix Christopher
Callbrated on WCCL system type 9700
Thts document shallnot be reproduced, exeent t ful, wihoutthe witlen approval tom West Catdwell GaL. Lebs, nc               Rev. 60 Sapt. 10, 2610 Doc. # 1098 HCRTEHC




                                                                                  Page 2 of 2




                                   «1more
                                        sX.                                            2o                                                  @uc


11.         CONCLUSION

The measurements indicate that the wireless communications device complies with the HAC limits
specified in accordance with the ANSI C63.19 Standard and FCC WT Docket No. 01-309 RM-8658.
Precise laboratory measures were taken to assure repeatability of the tests. The tested device complies
with the requirements in respect to all parameters specific to the test. The test results and statements
relate only to the item(s) tested.

The measurement system and techniques presented in this evaluation are proposed in the ANSI standard
as a means of best approximating wireless device compatibility with a hearing-aid. The literature is under
continual re-construction.




                                                                                             Reviewed by:
FCC ID: ZNFUN160                                    HAC (T-COIL) TEST REPORT
                                                                                             Quality Manager
Filename:                   Test Dates:              EUT Type:
                                                                                             Page 32 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012    Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                         REV 6.4C
                                                                                                    04/05/10


12.         REFERENCES

     1. ANSI C63.19-2007, American National Standard for Methods of Measurement of Compatibility
        between Wireless communication devices and Hearing Aids.”, New York, NY, IEEE, June 2007

     2. FCC Public Notice DA 06-1215, Wireless Telecommunications Bureau and Office of Engineering
        and Technology Clarify Use of Revised Wireless Phone Hearing Aid Compatibility Standard, June
        6, 2006

     3. FCC 3G Review Guidance, Laboratory Division OET FCC, May/June 2006

     4. Berger, H. S., “Compatibility Between Hearing Aids and Wireless Devices,” Electronic Industries
        Forum, Boston, MA, May, 1997

     5. Berger, H. S., “Hearing Aid and Cellular Phone Compatibility: Working Toward Solutions,”
        Wireless Telephones and Hearing Aids: New Challenges for Audiology, Gallaudet University,
        Washington, D.C., May, 1997 (To be reprinted in the American Journal of Audiology).

     6. Berger, H. S., “Hearing Aid Compatibility with Wireless Communications Devices, “ IEEE
        International Symposium on Electromagnetic Compatibility, Austin, TX, August, 1997.

     7. Bronaugh, E. L., “Simplifying EMI Immunity (Susceptibility) Tests in TEM Cells,” in the 1990 IEEE
        International Symposium on Electromagnetic Compatibility Symposium Record, Washington,
        D.C., August 1990, pp. 488-491

     8. Byme, D. and Dillon, H., The National Acoustics Laboratory (NAL) New Procedure for Selecting
        the Gain and Frequency Response of a Hearing Aid, Ear and Hearing 7:257-265, 1986.

     9. Crawford, M. L., “Measurement of Electromagnetic Radiation from Electronic Equipment using
        TEM Transmission Cells, “ U.S. Department of Commerce, National Bureau of Standards, NBSIR
        73-306, Feb. 1973.

     10. Crawford, M. L., and Workman, J. L., “Using a TEM Cell for EMC Measurements of Electronic
         Equipment,” U.S. Department of Commerce, National Bureau of Standards. Technical Note 1013,
         July 1981.
                                                                 st
     11. EHIMA GSM Project, Development phase, Project Report (1 part) Revision A. Technical-
         Audiological Laboratory and Telecom Denmark, October 1993.

     12. EHIMA GSM Project, Development phase, Part II Project Report. Technical-Audiological
         Laboratory and Telecom Denmark, June 1994.

     13. EHIMA GSM Project Final Report, Hearing Aids and GSM Mobile Telephones: Interference
         Problems, Methods of Measurement and Levels of Immunity. Technical-Audiological Laboratory
         and Telecom Denmark, 1995.

     14. HAMPIS Report, Comparison of Mobile phone electromagnetic near field with an upscaled
         electromagnetic far field, using hearing aid as reference, 21 October 1999.

     15. Hearing Aids/GSM, Report from OTWIDAM, Technical-Audiological Laboratory and Telecom
         Denmark, April 1993.

                                                                                             Reviewed by:
FCC ID: ZNFUN160                                    HAC (T-COIL) TEST REPORT
                                                                                             Quality Manager
Filename:                   Test Dates:              EUT Type:
                                                                                             Page 33 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012    Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                         REV 6.4C
                                                                                                    04/05/10


     16. IEEE 100, The Authoritative Dictionary of IEEE Standards Terms, Seventh Edition.

     17. Joyner, K. H, et. al., Interference to Hearing Aids by the New Digital Mobile Telephone System,
         Global System for Mobile (GSM) Communication Standard, National Acoustic Laboratory,
         Australian Hearing Series, Sydney 1993.

     18. Joyner, K. H., et. al., Interference to Hearing Aids by the Digital Mobile Telephone System, Global
         System for Mobile Communications (GSM), NAL Report #131, National Acoustic Laboratory,
         Australian Hearing Series, Sydney, 1995.

     19. Kecker, W. T., Crawford, M. L., and Wilson, W. A., “Contruction of a Transverse Electromagnetic
         Cell”, U.S. Department of Commerce, National Bureau of Standards, Technical Note 1011, Nov.
         1978.

     20. Konigstein, D., and Hansen, D., “A New Family of TEM Cells with enlarged bandwidth and
                                                               th
         Optimized working Volume,” in the Proceedings of the 7 International Symposium on EMC,
         Zurich, Switzerland, March 1987; 50:9, pp. 127-132.

     21. Kuk, F., and Hjorstgaard, N. K., “Factors affecting interference from digital cellular telephones,”
         Hearing Journal, 1997; 50:9, pp 32-34.

     22. Ma, M. A., and Kanda, M., ”Electromagnetic Compatibility and Interference Metrology,” U.S.
         Department of Commerce, National Bureau of Standards, Technical Note 1099, July 1986, pp.
         17-43.

     23. Ma, M. A., Sreenivashiah, I. , and Chang, D. C., “A Method of Determining the Emission and
         Susceptibility Levels of Electrically Small Objects Using a TEM Cell,” U.S. Department of
         Commerce, National Bureau of Standards, Technial Note 1040, July 1981.

     24. McCandless, G. A., and Lyregaard, P. E., Prescription of Gain/Output (POGO) for Hearing Aids,
         Hearing Instruments 1:16-21, 1983

     25. Skopec, M., “Hearing Aid Electromagnetic Interference from Digital Wireless Telephones, “IEEE
         Transactions on Rehabilitation Engineering, vol. 6, no. 2, pp. 235-239, June 1998.

     26. Technical Report, GSM 05.90, GSM EMC Considerations, European Telecommunications
         Standards Institute, January 1993.

     27. Victorian, T. A., “Digital Cellular Telephone Interference and Hearing Aid Compatibility—an
         Update,” Hearing Journal 1998; 51:10, pp. 53-60

     28. Wong, G. S. K., and Embleton, T. F. W., eds., AIP Handbook of Condenser Microphones: Theory,
         Calibration and Measurements, AIP Press.




                                                                                                  Reviewed by:
FCC ID: ZNFUN160                                    HAC (T-COIL) TEST REPORT
                                                                                                  Quality Manager
Filename:                   Test Dates:              EUT Type:
                                                                                                  Page 34 of 37
0Y1211121637.ZNF            Novemeber 16-17, 2012    Portable Handset
© 2012 PCTEST Engineering Laboratory, Inc.                                                              REV 6.4C
                                                                                                         04/05/10