DFS Test Report

FCC ID: ZNFH960

Test Report

Download: PDF
FCCID_2762515

                    74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea
                               TEL: +82-31-645-6300         FAX: +82-31-645-6401



                                        FCC DFS REPORT
                                                 FCC Certification
Applicant Name:                                           Date of Issue:
LG Electronics MobileComm U.S.A., Inc.                    September 08, 2015
                                                          Test Site/Location:
                                                          HCT CO., LTD., 74, Seoicheon-ro 578beon-gil, Majang-
Address:                                                  myeon, Icheon-si, Gyeonggi-do, Korea
1000 Sylvan Avenue, Englewood Cliffs NJ 07632             Report No.: HCT-R-1509-F021
                                                          HCT FRN: 0005866421

FCC ID                       : ZNFH960
APPLICANT                    : LG Electronics MobileComm U.S.A., Inc.

FCC Model(s):                 LG-H960
Additional Model(s):          LGH960, H960, LG-H960P, LGH960P, H960P, LG-H960AR, LGH960AR, H960AR,
                              LG-H960YK, LGH960YK, H960YK
EUT Type:                     Cellular/PCS GSM/WCDMA/LTE Phone with WLAN, Bluetooth and NFC
Max. RF
                                                      Channel       Frequency
Output Power                                                                          Power   Power
                                Band      Mode       Bandwidth        Range
(Average):                                                                            (dBm)    (W)
                                                       (MHz)          (MHz)
                                         802.11a         20         5260 – 5320       14.62   0.0290
                                         802.11n         20         5260 – 5320       14.30   0.0269
                                         802.11n         40         5270 – 5310       12.77   0.0189
                               UNII2A
                                         802.11ac        20         5260 – 5320       15.14   0.0327
                                         802.11ac        40         5270 – 5310       12.80   0.0191
                                         802.11ac        80            5290           12.00   0.0158
                                         802.11a         20         5500 – 5720       14.00   0.0251
                                         802.11n         20         5500 – 5720       13.59   0.0229
                                         802.11n         40         5510 – 5710       12.50   0.0178
                               UNII2C
                                         802.11ac        20         5500 – 5720       14.51   0.0282
                                         802.11ac        40         5510 – 5710       12.51   0.0178
                                         802.11ac        80         5530 – 5690       12.30   0.0170


Frequency Range:              20MHz :5260 MHz - 5320 MHz (UNII 2A)/ 5500 MHz - 5720 MHz (UNII 2C)
                              40MHz :5270 MHz - 5310 MHz (UNII 2A)/ 5510 MHz - 5670 MHz (UNII 2C)
                              80MHz: 5290 MHz(UNII 2A)/ 5530 MHz - 5690 MHz(UNII 2C)

Modulation type               OFDM

FCC Classification:           Unlicensed National Information Infrastructure (UNII)

FCC Rule Part(s):             Part 15.407(DFS)




     F-01P-02-014 (Rev.00)                                                                       HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                                                     Page 2 of 23
                                                               Model: LG-H960




Engineering Statement:

 The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this

equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these

measurements, and for the qualifications of all persons taking them.

HCT CO., LTD. Certifies that no party to this application has subject to a denial of Federal benefits that includes FCC benefits pursuant

to section 5301 of the Anti-Drug Abuse Act of 1998,21 U.S. C.853(a)




Report prepared by                            Approved by
: Kyung Soo Kang                              : Sang Jun Lee
Test Engineer of RF Team                      Manager of RF Team

This report only responds to the tested sample and may not be reproduced, except in full, without written approval of the HCT Co., Ltd.




 F-01P-02-014 (Rev.00)
 FCC ID: ZNFH960                                                                                                        HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                              Page 3 of 23
                                             Model: LG-H960



                                        Version

 TEST REPORT NO.                DATE                                DESCRIPTION

HCT-R-1509-F021         September 08, 2015      - First Approval Report




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                   HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                                                                              Page 4 of 23
                                                                           Model: LG-H960



                                                     Table of Contents
1. GENERAL INFORMATION .......................................................................................................................... 5

2. EUT DESCRIPTION ..................................................................................................................................... 5

3. SCOPE ......................................................................................................................................................... 6

4. INSTRUMENT CALIBRATION..................................................................................................................... 6

5. FACILITIES AND ACCREDITATIONS ......................................................................................................... 6

      5.1 FACILITIES ......................................................................................................................................... 6

      5.2 EQUIPMENT ....................................................................................................................................... 6

6. SUMMARY OF TEST RESULTS ................................................................................................................. 7

7. DESCRIPTION OF DYNAMIC FREQUENCY SELECTION TEST.............................................................. 8

      7.1 APPLICABILITY ................................................................................................................................. 8

      7.2 REQUIREMENTS................................................................................................................................ 9

      7.3 DFS DETECTION THRESHOLD VALUES .................................................................................... 11

      7.4 PARAMETERS OF DFS TEST SIGNALS...................................................................................... 12

      7.5 TEST AND MEASUREMENT SYSTEM ......................................................................................... 14

      7.6 DESCRIPTION OF EUT.................................................................................................................. 16

      7.7 UNII2A TEST RESULT ................................................................................................................... 17

      7.8 UNII2C TEST RESULT ................................................................................................................... 20

8. LIST OF TEST EQUIPMENT ................................................................................................................... 23




 F-01P-02-014 (Rev.00)
 FCC ID: ZNFH960                                                                                                                               HCT Co.,Ltd.


      Report No.: HCT-R-1509-F021                                                                                     Page 5 of 23
                                                           Model: LG-H960


      1. GENERAL INFORMATION

Applicant:                     LG Electronics MobileComm U.S.A., Inc
Address:                       1000 Sylvan Avenue, Englewood Cliffs NJ 07632
FCC ID:                        ZNFH960
EUT Type:                      Cellular/PCS GSM/WCDMA/LTE Phone with WLAN, Bluetooth and NFC
Model name(s):                 LG-H960

Date(s) of Tests:              August 12, 2015 ~ September 8, 2015
Place of Tests:                HCT Co., Ltd.
                               74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea.
                               (IC Recognition No. : 5944A-3)


      2. EUT DESCRIPTION
FCC Model Name          LG-H960
                        LGH960, H960, LG-H960P, LGH960P, H960P, LG-H960AR, LGH960AR, H960AR,
Additional Model(s):
                        LG-H960YK, LGH960YK, H960YK
EUT Type                Cellular/PCS GSM/WCDMA/LTE Phone with WLAN, Bluetooth and NFC

Power Supply            DC 3.85 V

                        Model: BL-45B1F
Battery Infomation
                        Type: Li-ion Battery(Standard)

                        TX_20 MHz BW:           5260 MHz - 5320 MHz (UNII 2A)/ 5500 MHz - 5720 MHz (UNII 2C)


                        TX_40 MHz BW:           5270 MHz - 5310 MHz (UNII 2A)/ 5510 MHz - 5710 MHz (UNII 2C)


                        TX_80 MHz BW:           5290 MHz(UNII 2A)/ 5530 MHz - 5690 MHz(UNII 2C)
Frequency Range
                        RX_20 MHz BW:           5260 MHz - 5320 MHz (UNII 2A)/ 5500 MHz - 5720 MHz (UNII 2C)


                        RX_40 MHz BW:           5270 MHz - 5310 MHz (UNII 2A)/ 5510 MHz - 5710 MHz (UNII 2C)


                        RX_80 MHz BW:           5290 MHz(UNII 2A)/ 5530 MHz - 5690 MHz(UNII 2C)

Modulation Type         OFDM(802.11a, 802.11n, 802.11ac)

Antenna Specification   Manufacturer: LS Mtron Co. Ltd.

                        Antenna type: INTERNAL ANTENNA

                        Peak Gain : -0.95 dBi (5260~5325 UNII2A BAND) / -3.79 dBi (5500~5720 UNII2C BAND)




       F-01P-02-014 (Rev.00)
       FCC ID: ZNFH960                                                                                         HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                   Page 6 of 23
                                              Model: LG-H960


3. SCOPE
This report has been prepared to demonstrate compliance with the requirements for Dynamic
Frequency Selection(DFS) as stated in KDB 905462 D02 v01r02. Testing was performed in
accordance with the measurement procedure described in FCC KDB 905462 D02 v01.


4. INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein, has
been calibrated in accordance with the manufacturer's recommendations for utilizing calibration
equipments, which is traceable to recognized national standards.


5. FACILITIES AND ACCREDITATIONS

5.1 FACILITIES
The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the
radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si,
Gyeonggi-do, Korea The site is constructed in conformance with the requirements of ANSI C63.4.
(Version :2014) and CISPR Publication 22. Detailed description of test facility was submitted to the
Commission and accepted dated July 07, 2015 (Registration Number: 90661) / June 22, 2015 (IC
egistration Number: 5944A-5)


5.2 EQUIPMENT
Radiated emissions are measured with one or more of the following types of Linearly polarized
antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum
analyzers with pre-selectors and quasi-peak detectors are used to perform radiated measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test
Receivers. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also
used for making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring
Apparatus and Measurement Methods.”




 F-01P-02-014 (Rev.00)
 FCC ID: ZNFH960                                                                       HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                     Page 7 of 23
                                               Model: LG-H960


6. SUMMARY OF TEST RESULTS

 Band                   Parameter                         Limit                 Result



         Channel Move Time                   10 seconds                         PASS



                                             200 ms + aggregate of 60 ms over
UNII2A   Channel Closing Transmission Time                                      PASS
                                             remaining 10 second period



         Non-occupancy Period                30 minutes                         PASS




         Channel Move Time                   10 seconds                         PASS



                                             200 ms + aggregate of 60 ms over
UNII2C   Channel Closing Transmission Time                                      PASS
                                             remaining 10 second period



         Non-occupancy Period                30 minutes                         PASS




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                          HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                                      Page 8 of 23
                                                             Model: LG-H960


7. DESCRIPTION OF DYNAMIC FREQUENCY SELECTION TEST
7.1 APPLICABILITY
The following table from KDB905462 D02(05/15/2015) lists the applicable requirements for the
DFS testing. The device evaluated in this report is considered a client device without radar
detection capability.


                                                                            Operation Mode

                  Requirement                                      Client Without Radar      Client With Radar
                                                     Master
                                                                         Detection              Detection

    Non-Occupancy Period                               Yes               Not required               Yes

    DFS Detection Threshold                            Yes               Not required               Yes

    Channel Availability Check Time                    Yes               Not required           Not required

    Uniform Spreading                                  Yes               Not required           Not required

    U-NII Detection Bandwidth                          Yes               Not required               Yes

                                                  Table 1-1. DFS Applicability




                                                                            Operation Mode

                  Requirement                                      Client Without Radar      Client With Radar
                                                     Master
                                                                         Detection              Detection

    DFS Detection Threshold                            Yes               Not required               Yes

    Channel Closing Transmission Time                  Yes                   Yes                    Yes

    Channel Move Time                                  Yes                   Yes                    Yes

    U-NII Detection Bandwidth                          Yes               Not required               Yes

                                      Table 1-2. DFS Applicability During Normal Operation




 F-01P-02-014 (Rev.00)
 FCC ID: ZNFH960                                                                                          HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                Page 9 of 23
                                            Model: LG-H960

7.2 REQUIREMENTS
Per KDB905462 D02(05/15/2015) the following are the requirements for Client Devices:


   a) A Client Device will not transmit before having received appropriate control signals from a
       Master Device.
   b) A Client Device will stop all its transmissions whenever instructed by a Master Device to
       which it is associated and will meet the Channel Move Time and Channel Closing
       Transmission Time requirements.
       The Client Device will not resume any transmissions until it has again received control
       signals from a Master Device.
   c) If a Client Device is performing In-Service Monitoring and detects a Radar Waveform
       above the DFS Detection Threshold, it will inform the Master Device. This is equivalent to
       the Master Device detecting the Radar Waveform and d) through f) of section 5.1.1 apply.
   d) Irrespective of Client Device or Master Device detection the Channel Move Time and
       Channel Closing Transmission Time requirements remain the same.




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                     HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                                          Page 10 of 23
                                                         Model: LG-H960

Channel Move Time and Channel Closing Transmission Time requirements are listed following
table.

                                 Parameter                                                   Value

     Non-occupancy period                                            Minimum 30 minutes

     Channel Availability Check Time                                 60 seconds

                                                                     10 seconds
     Channel Move Time
                                                                     See Note 1.

                                                                     200 milliseconds + an

                                                                     Aggregate of 60 milliseconds over
     Channel Closing Transmission Time
                                                                     Remaining 10 second period. See Notes

                                                                     1 and 2.

                                                                     Minimum 100 % of the U-NII

     U-NII Detection Bandwidth                                       99 % transmission

                                                                     Power bandwidth. See Note 3.

     Note 1: Channel Move Time and the Channel Closing Transmission Time should be performed with

     Radar Type 0. The measurement timing begins at the end of the Radar Type 0 burst.

     Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning of

     The Channel Move Time plus any additional intermittent control signals required to facilitate a Channell move

     (an aggregate of 60 milliseconds) during the remainder of the 10 second period. The aggregate duration

     of control signals will not count quiet periods in between transmissions.

     Note3: During the U-NII Detection Bandwidth detection test, radar type 0 should be used.

     For each frequency step the minimum percentage of detection is 90 percent. Measurements are performed

     With no data traffic.



                                         Table 1-3: DFS Response requirements




 F-01P-02-014 (Rev.00)
 FCC ID: ZNFH960                                                                                              HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                                              Page 11 of 23
                                                              Model: LG-H960

7.3 DFS DETECTION THRESHOLD VALUES
The DFS detection thresholds are defined for Master devices and Client Devices with In-service
monitoring. These detection thresholds are listed in the following table.


                                                                                                   Value
       Maximum Transmit Power
                                                                                                   (See Notes 1 and 2)

       ≥ 200 milliwatt                                                                             -64 dBm

       < 200 milliwatt                                                                             -62 dBm

       Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.



       Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of

       the test transmission waveforms to account for variations in measurement equipment. This will

       ensure that the test signal is at or above the detection threshold level to trigger a DFS response.

              Table 1-4: Detection Thresholds for Master Devices and Client Devices with Radar Detection




 F-01P-02-014 (Rev.00)
 FCC ID: ZNFH960                                                                                                   HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                               Page 12 of 23
                                                 Model: LG-H960

7.4 PARAMETERS OF DFS TEST SIGNALS
As the EUT is a Client Device with no Radar Detection only one type radar pulse is required for the
testing. Radar Pulse type 0 was used in the evaluation of the Client device for the purpose of
measuring the Channel Move Time and the Channel Closing Transmission Time. Table 1-5 lists
the parameters for the Short Pulse Radar Waveforms. A plot of the Radar pulse Type 0 used for
testing is included in Section 7.7 of this report.




 F-01P-02-014 (Rev.00)
 FCC ID: ZNFH960                                                                      HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                               Page 13 of 23
                                                           Model: LG-H960



                                                                                         Minimum

                        Pulse                                      Number                Percentage   Minimum
                                            PRI
   Radar Type           Width                                          Of                    of       Number of
                                           (μsec)
                        (μsec)                                        Pulses             Successful     Trials

                                                                                         Detection

         0                1                1428                        18                See Note 1   See Note 1

                                     Test A: 15 unique      Roundup         1               60%           30

                                        PRI values                       360
                                                                                6
                                    Randomly selected                    19·10

                                     From the list of 23                 PRI µsec

                                       PRI values in
                                          Table 5a


                                     Test B: 15 unique

                                        PRI values

                                    Randomly selected
         1                1           within the range

                                        of 518-3066

                                       µ sec, with a

                                         minimum

                                      increment of 1

                                           µ sec,

                                       excluding PRI

                                           values

                                        selected in

                                           Test A


         2               1-5              150-230                     23-29                 60%           30

         3              6-10              200-500                     16-18                 60%           30

         4              11-20             200-500                     12-16                 60%           30

                                                                                            80%          120

  Note1: Short pulse Radar Type 0 should be used for the detection bandwidth test, channel move time, and channel

  closing time tests.

                                 Table 1-5: Parameters for Short Pulse Radar Waveforms




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                                       HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                   Page 14 of 23
                                                 Model: LG-H960

7.5 TEST AND MEASUREMENT SYSTEM

General Test Setup Procedure:
   1. The EUT was operating 802.11a mode (18Mbps) during the test.
   2. Connect FCC approved Master AP to a network, via wired Ethernet, that allows connection to an
       FTP server.
   3. Associate the EUT with the Master AP.
   4. Launch the FTP application on the EUT.
   5. Connect to the FTP server application to the FTP server hosting the file
   6. Initiate an FTP download of the file from the host.
   7. Monitor the channel loading during transfer.
   8. Reduce the maximum allowed data rate for the Master AP, using the AP’s GUI interface.
   9. Repeat steps 5-7 until the channel loading is as close to 20 % as possible.
   10. Record the data rate setting on the Master AP and the channel loading.
   11. While the system is performing an FTP transfer using the settings form item 9 above, perform the
       Channel Closing Transmission Time and Channel Move Time Measurements as required by
       KDB905462 D02(05/15/2015) using a conducted test.


PROCEDURE
 The KDB905462 D02(05/15/2015) describes a radiated test setup and a conducted test setup. A
radiated test setup was used for this testing. Figure 3-1 shows the typical test setup. Each one
channel selected between 5260 and 5320 MHz, 5500 and 5720 is chosen for the testing.




                                 Figure 3-1. Conducted Test Setup for DFS




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                           HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                        Page 15 of 23
                                                  Model: LG-H960

   1. The radar pulse generator is setup to provide a pulse at the frequency that the Master and Client are
       operating. A Type 0 radar pulse with a 1 μs pulse width and a 1428 μs PRI is used for the testing.

   2. The vector signal generator is adjusted to provide the radar burst (18 pulses) at a level of
       approximately -62 dBm at the antenna of the Master device.

   3. The Client Device (EUT) is set up per the diagram in Figure 3-1 and communications between the
       Master device and the Client is established.

   4. The MPEG file specified by the FCC (”6½ Magic Hours”) is streamed from the “file computer”
       through the Master to the Slave Device and played in full motion video using Media Player Classic
       Ver.6.4.8.6 in order to properly load the network.

   5. The real time spectrum analyzer is set to record about 15 sec window to any transmissions
       occurring up to and after 10 sec.

   6. The system is again setup and the monitoring time is shortened in order to capture the Channel
       Closing Transmission Time. This time is measured to insure that the Client ceases transmission
       within 200 ms and the aggregate of emissions occurring after 200 ms up to 10 sec do not exceed 60
       ms.

       (Note: the channel may be different since the Master and Client have changed channels due to the
       detection of the initial radar pulse.)


   7. After the initial radar burst the channel is monitored for 30 minutes to insure no transmissions or
       beacons occur. A second monitoring setup is used to verify that the Master and Client have both
       moved to different channels.


SYSTEM CALIBRATION
      A-50-ohm load is connected in place of the spectrum analyzer, and the spectrum analyzer is
     connected to a coaxial cable. The signal generator is set to CW mode. The amplitude of the
     signal generator is adjusted to yield a level of - 62 dBm as measured on the spectrum analyzer.


      Without changing any of the instrument settings, the spectrum analyzer is reconnected to the
     common port of the spectrum analyzer combiner or divider.


      The spectrum analyzer displays the level of the signal generator higher than the client TX
     level. Because we can not search the signal generator in the spectrum analyzer when the
     signal generator level is - 62 dBm. The spectrum analyzer will still indicate the level higher
     than the client TX level.

F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                                HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                       Page 16 of 23
                                                  Model: LG-H960

7.6 DESCRIPTION OF EUT

The EUT operates over the 5260 MHz - 5320 MHz and 5500 MHz - 5720 MHz ranges.


The EUT is a slave device without radar detection.


The EUT antenna has a gain of -0.95 dBi in 5260 MHz - 5320 MHz band and -3.79 dBi in
5500 MHz- 5720 MHz band.


The highest power level within these bands in 14.19 dBm EIRP in the
5260 MHz - 5320 MHz band and 10.72 dBm EIRP in the 5500 MHz – 5720 MHz band.


The EUT one transmitter/receiver chain connected to a coaxial cable to perform conducted tests.


TPC is not required since the maximum EIRP is less than 500 mW.


The EUT utilizes the 802.11a/n/ac architecture.
Three nominal channel bandwidth is implemented: 20 MHz, 40 MHz and 80 MHz




 F-01P-02-014 (Rev.00)
 FCC ID: ZNFH960                                                                             HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                             Page 17 of 23
                                           Model: LG-H960

7.7 UNII2A TEST RESULT
   ▣ RESULT PLOTS(UNII2A Band)
                                 Type0 Radar Pulse Number – Ch.60




   Marker Descriptions:
   Number of Pulse Form M1R to M1 : 18
                                            Type0 PRI




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                     HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                        Page 18 of 23
                                           Model: LG-H960



                              Time Display, Non WLAN Channel Traffic




                        Time Display, WLAN Channel Traffic (Streaming Video)




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                       Page 19 of 23
                                               Model: LG-H960




    ㆍChannel Move Time : 0.156022 s(Limit : 10 s)
    ㆍChannel Closing Transmission Time, Aggregate Time After 200 ms : 0.000270 s(Limit : 60 ms)




             Non-occupancy Period – Monitoring live real time spectrum – Elapse time 30 minutes




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                            HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                              Page 20 of 23
                                           Model: LG-H960

7.8 UNII2C TEST RESULT
     ▣ RESULT PLOTS_(UNII2C Band)
                                 Type0 Radar Pulse Number – Ch.100




   Marker Descriptions:
   Number of Pulse Form M1R to M1 : 18
                                            Type0 PRI




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                      HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                        Page 21 of 23
                                           Model: LG-H960

                              Time Display, Non WLAN Channel Traffic




                        Time Display, WLAN Channel Traffic (Streaming Video)




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                        Page 22 of 23
                                                Model: LG-H960




ㆍChannel Move Time : 0.136564 s(Limit : 10 s)
ㆍChannel Closing Transmission Time, Aggregate Time After 200 ms : 0.000413 s(Limit : 60 ms)




              Non-occupancy Period – Monitoring live real time spectrum – Elapse time 30 minutes




 F-01P-02-014 (Rev.00)
 FCC ID: ZNFH960                                                                            HCT Co.,Ltd.


Report No.: HCT-R-1509-F021                                                                               Page 23 of 23
                                                     Model: LG-H960


8. LIST OF TEST EQUIPMENT

                                                                Calibration   Calibration
        Manufacturer                 Model / Equipment                                       Serial No.
                                                                   Date        Interval

                                                                                            S2LF812265
     SAMSUNG            WEA453e / Wireless AP
                                                                   N/A           N/A          FCC ID:
     ELECTRONICS        (Master Device)
                                                                                            A3LWEA453E

     ADLINK             PXI/DFS Measurement System              11/25/2014     Annual       301081/711

     Agilent            N9020A / SIGNAL ANALYZER                06/30/2015     Annual       MY51110085

     Agilent            N9020A / SIGNAL ANALYZER                07/02/2015     Annual       MY50510304

     Agilent            N1911A/Power Meter                      07/09/2015     Annual       MY45100523

     Agilent            N1921A /POWER SENSOR                    07/09/2015     Annual       MY45241059

     Hewlett Packard    11636B/Power Divider                    10/28/2014     Annual         11377

     Agilent            87300B/Directional Coupler              12/08/2014     Annual       3116A03621

     Hewlett Packard    11667B / Power Splitter                 06/11/2015     Annual          5001

     DIGITAL            EP-3010 /DC POWER SUPPLY                10/30/2014     Annual         3110117

     Agilent            8493C / Attenuator(10 dB)               08/20/2015     Annual         76649

     WEINSCHEL          2-3 / Attenuator(3 dB)                  10/30/2014     Annual         BR0617




F-01P-02-014 (Rev.00)
FCC ID: ZNFH960                                                                                    HCT Co.,Ltd.



Document Created: 2015-09-16 10:04:39
Document Modified: 2015-09-16 10:04:39