User manual rev.1

FCC ID: ZKJ-KITCHENHUB1

Users Manual

Download: PDF
FCCID_4178307

KITCHEN HUB™
                 SAFETY INFORMATION. . . . . . . . . . . . . .3                                       OWNER’S MANUAL &
                 USING THE KITCHEN HUB                                                                  INSTALLATION
                 Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     .5        INSTRUCTIONS
                 Control Features . . . . . . . . . . . . . . . . . . . . . . . . . .         .5
                 Wi-Fi Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . .         6                 UVH1301
                 Chef Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . .          6

                 CARE AND CLEANING
                 Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
                 Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

                 INSTALLATION INSTRUCTIONS                                      ... 9
                 Mounting Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
                 Installation Types . . . . . . . . . . . . . . . . . . . . . . . . . 17
                   A. Outside Top Exhaust . . . . . . . . . . . . . . . . . . 18
                   B. Recirculating . . . . . . . . . . . . . . . . . . . . . . . . 22
                   C. Outside Back Exhaust . . . . . . . . . . . . . . . . 25

                 TROUBLESHOOTING TIPS . . . . . . . . .                                     28

                 LIMITED WARRANTY                                . . . . . . . . . . . . . . 29

                 ACCESSORIES                      . . . . . . . . . . . . . . . . . . . . . . 30

                 CONSUMER SUPPORT . . . . . . . . . . . . .                                 32




                                  Write the model and serial                                                                ESPAÑOL
                                  numbers here:                                                            Para consultar una version en
                                                                                                              español de este manual de
                                  Model # _________________                                         instrucciones, visite nuestro sitio de
                                                                                                            internet GEAppliances.com.
                                  Serial # _________________

                                  You can find them on a label
                                  on the inside of the unit behind
                                  the filters.


           GE is a trademark of the General Electric Company. Manufactured under trademark license.

                                                                                                      49-2000492 Rev. 0 01-19 GEA


      THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.

Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
   We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
        can deliver important product information and warranty details when you need them.
 Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration
                             card included in the packing material.




2                                                                                            49-2000492 Rev. 0


IMPORTANT SAFETY INFORMATION




                                                                                                                        SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING
         WARNING TO REDUCE THE RISK OF FIRE,                     WARNING TO REDUCE THE RISK OF INJURY
   ELECTRIC SHOCK OR INJURY TO PERSONS,                       TO PERSONS IN THE EVENT OF A RANGE TOP
   OBSERVE THE FOLLOWING:                                     GREASE FIRE, OBSERVE THE FOLLOWING*:
   A. Use this unit only in the manner intended by the        A. SMOTHER FLAMES with a close-fitting lid, cookie
      manufacturer. If you have questions, contact the           sheet or metal tray, then turn off the burner. BE
      manufacturer.                                              CAREFUL TO PREVENT BURNS. If the flames
   B. To avoid the risk of scald injury from a hot cooktop,      do not go out immediately, EVACUATE AND CALL
      keep young children away from the touchscreen.             THE FIRE DEPARTMENT.
   C. Before servicing or cleaning unit, switch power off     B. NEVER PICK UP A FLAMING PAN—You may be
      at service panel and lock the service disconnecting        burned.
      means to prevent power from being switched              C. DO NOT USE WATER, including wet dishcloths or
      on accidentally. When the service disconnecting            towels—a violent steam explosion will result.
      means cannot be locked, securely fasten a               D. Use an extinguisher ONLY if:
      prominent warning device, such as a tag, to the            1. You know you have a Class ABC extinguisher,
      service panel.                                                and you already know how to operate it.
   D. Do not use this unit with any solid-state speed            2. The fire is small and contained in the area where
      control device.                                               it started.
   E. This unit must be grounded.                                3. The fire department is being called.
         CAUTION FOR GENERAL VENTILATING USE                     4. You can fight the fire with your back to an exit.
                                                              *Based on “Kitchen Fire Safety” published by NFPA.
   ONLY. DO NOT USE TO EXHAUST HAZARDOUS
   OR EXPLOSIVE MATERIALS AND VAPORS.                            WARNING TO REDUCE THE RISK OF A
         CAUTION TO REDUCE RISK OF FIRE AND                   RANGE TOP GREASE FIRE:
   TO PROPERLY EXHAUST AIR, BE SURE TO DUCT                   A. Never leave surface units unattended. Boilovers
   AIR OUTSIDE. DO NOT VENT EXHAUST AIR INTO                     cause smoking and greasy spillovers that may
   SPACES WITHIN WALLS OR CEILINGS OR INTO                       ignite. Heat oils slowly on medium settings.
   ATTICS, CRAWL SPACES OR GARAGES.                           B. Always turn fan ON when cooking at high heat or
                                                                 when flambéing food (i.e. Crepes Suzette, Cherries
                                                                 Jubilee, Peppercorn Beef Flambé).
                                                              C. Clean ventilating fans frequently. Grease should not
                                                                 be allowed to accumulate on fan or filter.
                                                              D. Use proper pan size. Always use cookware
                                                                 appropriate for the size of the surface element.




                    READ AND SAVE THESE INSTRUCTIONS
49-2000492 Rev. 0                                                                                                       3


                     IMPORTANT SAFETY INFORMATION
SAFETY INFORMATION


                     READ ALL INSTRUCTIONS BEFORE USING
                     NOTE: This equipment has been tested and found                 which can be determined by turning the equipment
                     to comply with the limits for a Class B digital device,        off and on, the user is encouraged to try to correct the
                     pursuant to part 15 of the FCC Rules. These limits             interference by one or more of the following measures:
                     are designed to provide reasonable protection against          Ŷ Reorient or relocate the receiving antenna.
                     harmful interference in a residential installation. This
                     equipment generates, uses and can radiate radio                Ŷ Increase the separation between the equipment and
                     frequency energy and, if not installed and used in                receiver.
                     accordance with the instructions, may cause harmful            Ŷ Connect the equipment into an outlet on a circuit
                     interference to radio communications. However, there              different from that to which the receiver is connected.
                     is no guarantee that interference will not occur in a
                                                                                    Ŷ Consult the dealer or an experienced radio/TV
                     particular installation. If this equipment does cause
                                                                                       technician for help.
                     harmful interference to radio or television reception,

                     This device contains licence-exempt transmitter(s)/            Les antennes installées doivent être situées de facon
                     receiver(s) that comply with Innovation, Science and           à ce que la population ne puisse y être exposée à une
                     Economic Development Canada’s licence-exempt RSS(s).           distance de moin de 20 cm. Installer les antennes de
                     Operation is subject to the following two conditions:          facon à ce que le personnel ne puisse approcher à 20
                     (1) This device may not cause interference.                    cm ou moins de la position centrale de l’ antenne.

                     (2) This device must accept any interference, including        La FCC des éltats-unis stipule que cet appareil doit être
                         interference that may cause undesired operation of         en tout temps éloigné d’au moins 20 cm des personnes
                         the device.                                                pendant son functionnement.

                     L’émetteur/récepteur exempt de licence contenu dans            Limited by local law regulations, version for North
                     le présent appareil est conforme aux CNR d’Innovation,         America does not have region selection option.
                     Sciences et Développement économique Canada                    The device for operation in the band 5150-5250 MHz is
                     applicables aux appareils radio exempts de licence.            only for indoor use to reduce the potential for harmful
                     L’exploitation est autorisée aux deux conditions suivantes :   interference to co-channel mobile satellite systems.
                     1) L’appareil ne doit pas produire de brouillage;              Les dispositifs fonctionnant dans la bande de 5 150 à 5
                     2) L’appareil doit accepter tout brouillage radioélectrique    250 MHz sont réservés uniquement pour une utilisation
                        subi, même si le brouillage est susceptible d’en            à l'intérieur afin de réduire les risques de brouillage
                        compromettre le fonctionnement.                             préjudiciable aux systèmes de satellites mobiles utilisant
                                                                                    les mêmes canaux.
                     To satisfy FCC / IC RF exposure requirements, a
                     separation distance of 20 cm or more should be                 Changes or modifications not expressly approved by the
                     maintained between the antenna of this device and              party responsible for compliance could void the user's
                     persons during device operation.                               authority to operate the equipment.

                     To ensure compliance, operations at closer than this
                     distance is not recommended.


                     How to Remove Protective Shipping Film and Packaging Tape
                     Carefully grasp a corner of the protective shipping film       To assure no damage is done to the finish of the product,
                     with your fingers and slowly peel it from the appliance        the safest way to remove the adhesive from packaging
                     surface. Do not use any sharp items to remove the film.        tape on new appliances is an application of a household
                     Remove all of the film before using the appliance for the      liquid dishwashing detergent. Apply with a soft cloth and
                     first time.                                                    allow to soak.
                                                                                    NOTE: The adhesive must be removed from all parts.
                                                                                    NOTE: For further cleaning instructions/suggestions,
                                                                                    please refer to the Care And Cleaning section.




              4                                                                                                                      49-2000492 Rev. 0


Hardware




                                                                                                                                                                                                               USING THE KITCHEN HUB: Hardware / Contol Features
                                          Front
                                        Camera


                        Screen


                                                                                                    LVYLOOH
                                                                                          25 F | LRX




                                                                              8:50      Monday, Fe
                                                                                                         bruary 12
                                                                                                                                                                                           Speaker


                                                                                                                                                                                      Volume Button

                                             Swipe up on the screen                                                                                                                           On/Off
                                                 to access controls.
                                                                                                                                        Google
                                                                                                                                Skype
                                                                                                             U+ Connect
                                                                                           Music                                   n
                                                                                  ent                                     Blue Apro
                                                                        Entertainm                 6SRWLI\
                                                              Recipes             HV«
                                                                         3OD\0RYL

                                                 Hulu
                                                            1HWÀL[
                                                                                                                                                                                       Cooktop Camera




                                                                                                                                                         Lights




Control Features
                                 3           4                           5                                            7                                 8                  9




                    1
                                                 FAN                                                                                                              LIGHT
                                 OFF   LOW          MED                 HIGH BOOST                                                                OFF              DIM         HIGH



                                                        2                                                                                                           6


1.      Ventilation Fan and Light Control Screen                                                                                                 6.   LIGHT: Light level control. Tap DIM for low light, MED
2.      FAN: Speed control for fan. Tap LOW for LOW                                                                                                   for medium light, and HIGH for bright light.
        speed. MED for MEDIUM speed and HIGH for                                                                                                 7.   Lock: Select to lock screen controls.
        HIGH speed. Tap BOOST for BOOST speed.                                                                                                   8.   Volume: Slide to increase or decrease media
3.      Camera: Select to take a picture of your cooking                                                                                              volume.
        surface.                                                                                                                                 9.   Brightness: Slide to increase or decrease screen
4.      Microphone: Select to mute/unmute.                                                                                                            brightness.
5.      Notification: Select to turn notification sounds on                                                                                      For Android device setup, and for Android help, please
        and off.                                                                                                                                 reference the Setup Wizard on the Kitchen Hub.




49-2000492 Rev. 0                                                                                                                                                                                              5


                                                                         USING THE KITCHEN HUB
USING THE KITCHEN HUB: WiFi / Heat Sensor / Screen Moisture Protection


                                                                         Connecting your WiFi Connect Enabled Appliance
                                                                         Your GE Appliances Kitchen Hub is recommended to be      Use the Setup Wizard to connect unit to WiFi.
                                                                         connected to WiFi.



                                                                         Heat Sensor
                                                                         This unit is equipped with a heat sensor that will       If FAN is OFF and excessive temperature is detected,
                                                                         activate the ventilation FAN if excessive temperatures   the FAN will automatically turn to LOW speed. You may
                                                                         are detected above the cooktop surface to protect the    adjust FAN speed to MEDIUM, HIGH, or BOOST, but
                                                                         Kitchen Hub components from overheating.                 you will not be able to turn to OFF until temperatures
                                                                                                                                  return to an acceptable level.



                                                                         Screen Moisture Protection System
                                                                         Your Kitchen Hub is equipped with a screen protection    The system is on while the screen is in the awake
                                                                         system. The system expels small amounts of air around    state and off when the screen is in screensaver mode
                                                                         and below the screen to keep the touchscreen area        or off position. Operating the cooktop while screen
                                                                         dry and clean by preventing condensation or other        protection system is off may result in condensation
                                                                         substances during cooktop operation.                     on the touchscreen. It is recommended to activate
                                                                                                                                  screen during cooking to prevent this from happening. If
                                                                                                                                  condensation build up continues while protection system
                                                                                                                                  is active, turn the ventilation FAN on to provide additional
                                                                                                                                  protection.




                                                        6                                                                                                                          49-2000492 Rev. 0


Filters




                                                                                                                               USING THE KITCHEN HUB: Filters
Be sure the circuit breaker is off and all surfaces are cool before cleaning or servicing any interior part of the unit.
Metal Grease Filter
The metal filters trap grease during cooking.
The filters must ALWAYS be in place when the unit is in
use. The grease filters are dishwasher-safe and should
be cleaned every month, depending on the usage of the
unit.
To remove:
Press on the filter handle to disengage the filter lock to
release the filter.
To replace:
Fit the tabs at the bottom of the filter into the slots in the
back of the filter opening. Lift up the front side of the filter
and push gently until the filter locks into place. Make sure
the filter lock is in the closed position to secure the filter.
To clean:
Swish the filter in hot soapy water and rinse in clean
                                                                                                             Metal Grease
water or wash it in the dishwasher. Do not use abrasive
                                                                                                             Filter
cleansers.
NOTE: Some discoloration of the filter may occur in the
dishwasher.




Charcoal Filter (for recirculation installation only)
If the model is not vented to the outside, the air needs to        To remove:
be recirculated through a disposable charcoal filter that          1. Remove the metal filters—see Metal grease filter
helps remove smoke and odors.                                         section.
NOTE: DO NOT rinse, or put charcoal filter in an                   2. Remove the charcoal filter on each side of the blower.
automatic dishwasher.
The charcoal filters are included with the unit. They
cannot be cleaned. It is recommended that the
charcoal filter be replaced every 6 months or if it is
noticeably dirty or discolored.                                                                             Charcoal
Order Charcoal Filter UXCF91                                                                                Filter Mount

To inquire about purchasing replacement charcoal filters
or to find the location of a dealer nearest you, please call
our toll-free number:
National Parts Center 800.626.2002
To install:
1. Remove the metal filters—see Metal Grease Filter
   section.
2. Install the charcoal filter mounts to either side of the
   motor.
3. Insert the snap on the charcoal filter into the center on
   the mount.
4. Clip the charcoal filter in until it is locked.
5. Repeat with second filter on the other side of the motor.
6. Replace the metal filters - See Metal Grease Filter section.


49-2000492 Rev. 0                                                                                                              7


                              Surfaces
CARE AND CLEANING: Surfaces


                              Stainless Steel Surfaces (on some models)
                              Do not use a steel wool pad; it will scratch the             Use only a liquid cleanser free of grit and rub in the
                              surface.                                                     direction of the brush lines with a damp soft sponge.
                              To clean the stainless steel surface, use warm sudsy         To inquire about purchasing stainless steel appliance
                              water or a stainless steel cleaner or polish. Always wipe    cleaner or polish, or to find the location of a dealer
                              the surface in the direction of the brush line. Follow       nearest you, please call our toll-free number:
                              the cleaner instructions for cleaning the stainless steel    National Parts Center
                              surface. Cleaners with oxalic acid such as Bar Keepers       800.626.2002
                              Friend Soft Cleanser™ will
                              remove surface rust, tarnish, and                            GEApplianceParts.com
                              small blemishes. To receive a
                              coupon for a trial sample of Bar
                              Keepers Friend Soft Cleanser™
                              follow the link below or scan the
                              QR Code.
                              barkeepersfriend.com/ge


                              Painted Surfaces and Black Stainless Color (on some models)
                              Do not use a steel wool pads or other abrasive               NOTE: When cleaning, take care not to come in contact
                              cleaners; they will scratch the surface.                     with filters and other surfaces.
                              Clean grease-laden surfaces frequently. To clean
                              the outer surface, use a hot, damp cloth with a mild
                              detergent suitable for painted surfaces. Use a clean, hot,
                              damp cloth to remove soap. Dry with a dry, clean cloth.



                              How to Clean the Outside
                              We recommend against using cleaners with                     Screen
                              ammonia or alcohol, as they can damage the                   Wipe with a damp cloth or glass cleaner such as
                              appearance of the appliance. If you choose to use            Windex. Dry thoroughly. Do not use large amounts of
                              a common household cleaner, first apply the cleaner          soap and water, sharp objects or abrasives - they can
                              directly to a clean cloth, then wipe the soiled area.        damage it.
                              Case                                                         Bottom
                              Clean the outside of the appliance with a sudsy cloth.       Clean off the grease and dust on the bottom often. Use a
                              Rinse and then dry. Do not use appliance wax, polish,        solution of warm water and detergent.
                              bleach or products containing chlorine on Stainless Steel    Cooktop Camera
                              finishes.                                                    Use a dry, soft cloth to clean the cooktop camera.




                     8                                                                                                                     49-2000492 Rev. 0


                                                                                                                    INSTALLATION INSTRUCTIONS
    Installation                                                   Kitchen Hub
    Instructions                                                           UVH1301



         “If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737)
         or visit our website at: GEAppliances.com”


   BEFORE YOU BEGIN                                             WARNING TO REDUCE THE RISK OF FIRE,
   Read these instructions completely and carefully.         ELECTRIC SHOCK OR INJURY TO PERSONS,
                                                             OBSERVE THE FOLLOWING:
   Ŷ   IMPORTANT                  — Save these
                                                             A. Installation work and electrical wiring must be
       instructions for local inspector’s use.
                                                                done by qualified person(s) in accordance with
   Ŷ   IMPORTANT — Observe all governing                        all applicable codes and standards, including
                                                                fire-rated construction.
       codes and ordinances.
   Ŷ Note to Installer – Be sure to leave these              B. Sufficient air is needed for proper combustion
                                                                and exhausting of gases through the flue
       instructions with the Consumer.
                                                                (chimney) of fuel burning equipment to prevent
   Ŷ Note to Consumer – Keep these instructions for             back drafting. Follow the heating equipment
       future reference.                                        manufacturer’s guidelines and safety standards
   Ŷ Skill level – Installation of this appliance requires      such as those published by the National Fire
       basic mechanical and electrical skills.                  Protection Association (NFPA), the American
   Ŷ Completion time – Approximately 1 to 3 hours               Society for Heating, Refrigeration and Air
                                                                Conditioning Engineers (ASHRAE) and the local
   Ŷ Proper installation is the responsibility of the           code authorities.
       installer.
                                                             C. When cutting or drilling into wall or ceiling, do
   Ŷ Product failure due to improper installation is not        not damage electrical wiring and other hidden
       covered under the Warranty.                              utilities.
                                                             D. Ducted fans must always be vented to the
                                                                outdoors.
                                                             E. When applicable, install any makeup
                                                                (replacement) air system in accordance with local
                                                                building code requirements. Visit GEAppliances.
                                                                com for available makeup air solutions.
                                                                WARNING TO REDUCE THE RISK OF FIRE,
                                                             USE ONLY METAL DUCT WORK.




49-2000492 Rev. 0                                                                                                   9


                                                             Installation Instructions
INSTALLATION INSTRUCTIONS



                            IMPORTANT SAFETY INSTRUCTIONS
                            GROUNDING INSTRUCTIONS                                       CAUTION For personal safety, the
                            This appliance must be grounded. In the event of an
                            electrical short circuit, grounding reduces the risk of   mounting surface must be capable of supporting
                            electric shock by providing an escape wire for the        the cabinet load of this 75 pound product.
                            electric current. This appliance is equipped with a
                            cord
                                                                                         CAUTION For personal safety, this product
                            having a grounding wire with a grounding plug. The        cannot be installed in cabinet arrangements
                            plug must be plugged into an outlet that is properly      such as an island or a peninsula. It must be
                            installed and grounded.                                   mounted to BOTH a top cabinet AND a back
                                                                                      wall.
                               WARNING Improper grounding can result in
                            a risk of electric shock.                                    CAUTION To avoid the risk of personal
                            Consult a qualified electrician if the grounding          injury (back injury or other injuries due to
                            instructions are not completely understood, or if         excessive weight of the product) or property
                            doubt exists as to whether the appliance is properly      damage, you will need two people to install this
                            grounded.                                                 product.
                            Do not use an extension cord. If the power supply
                            cord is too short, have a qualified electrician install
                            an outlet near the appliance.
                                                                                      ELECTRICAL REQUIREMENTS
                                                                                      120 V Models
                            Where a standard two-prong wall receptacle                This product requires a three-prong grounded
                            is encountered, it must be replaced with                  outlet. Product rating is 120 volts AC, 60 Hertz.
                            a properly grounded three-prong wall                      This product must be connected to a supply circuit
                            receptacle, installed by a qualified electrician.         of the proper voltage and frequency. Wire size
                                                                                      must conform to the requirements of the National
                               WARNING Risk of Electric Shock.                        Electrical Code or the prevailing local code. The
                            Can cause injury or death: DO NOT, under any              outlet box should be located in the cabinet above
                            circumstances, cut, deform or remove any of the           the unit and away from any potential ducting. The
                            prongs from the power cord. Failure to comply             outlet box and supply circuit should be installed by
                            may cause fire.                                           a qualified electrician and conform to the National
                                                                                      Electrical Code or the prevailing local code.




                    10                                                                                                              49-2000492 Rev. 0


                                     Installation Instructions




                                                                                                                                 INSTALLATION INSTRUCTIONS
    MOUNTING SPACE
                                                 Bottom edge of      NOTES:
                                                  cabinet needs
                                                    WREHƎRU    ‡7KHVSDFHEHWZHHQWKHFDELQHWVPXVWEHƎZLGH
                     Ǝ                              more from
                    max.                                               and free of obstructions.
                                                     the cooking
                                                       surface or    • If you are going to vent your unit to the outside,
                                                      top surface
                                                  of gas grates,
                                                                       see Installation Types 2A or 2C for cabinet and wall
                      òƎ            Ǝ
                              Ǝ                 whichever is        preparation.
                                       min.
                                                            taller
                                                                     • When installing the unit beneath smooth, flat
                              Ǝ                                       cabinets, be careful to follow the instructions on the
                                              Backsplash
   ƎPLQIURP                                                       top cabinet template for power cord clearance.
   the floor to
   the bottom of                                                     • Maximum cabinet depth above and beside the unit
   the cabinet.                                                        is 13” max for standard installation. 15" cabinet
   69" is the
   recommended                                                         depth requires additional steps using an additional
   distance.                                                           installation kit JKX15BUMPWW/BB.
                                                                     • For models setup in Recirc Exhaust: Do not allow
                                                                       cabinetry or other objects to block the airflow of the
                                                                       vent.
                                                                     • The product should not be installed over any cooktop
                                                                       or range with a combined cooktop BTU greater than
                                                                       72,000 BTU.




49-2000492 Rev. 0                                                                                                               11


                                                                   Installation Instructions
INSTALLATION INSTRUCTIONS



                            TOOLS AND MATERIALS REQUIRED                                      PARTS NEEDED FOR INSTALLATION
                            (NOT SUPPLIED)                                                    Ŷ 1 Wall or Roof Cap (for ducted venting only)
                                                                                              Ŷ All Metal Ductwork (for ducted venting only)


                                                                   Safety glasses             DAMAGE – SHIPMENT/INSTALLATION
                             Pencil and tape measure                                          • If the unit is damaged in shipment, return the
                                                                                                unit to the store in which it was bought for repair or
                                                                     Phillips screwdriver       replacement.
                                                                                              • If the unit is damaged by the customer, repair or
                                        Level
                                                                                                replacement is the responsibility of the customer.
                                                                                              • If the unit is damaged by the installer (if other
                                                                                                than the customer), repair or replacement must
                                                                          Aluminized            be made by arrangement between customer and
                               Rectangular duct and                        duct tape            installer.
                              adaptors as needed per
                                    installation
                                 (length will vary)
                                                                                              PARTS INCLUDED
                                                                            Gloves            HARDWARE PACKET
                                                                                                   PART                                  QUANTITY
                                                                                                                Wood Screws                   2
                                                                                                                (3/16” x 2”)
                                        Tin snips
                                                                   Scissors (to cut                             Toggle Bolts (and             4
                                                                   template, if necessary)
                                                                                                                wing nuts) (1/4” x 3”)


                                                                                                                Self-aligning                 3
                                                                                                                Machine Screw
                                                                                                                (1/4”-28 x 3-1/4”)
                             Electric drill with #2 Phillips bit
                                                                    Filler blocks or scrap
                                                                    wood pieces, if needed                      Nylon Grommet (for            1
                                                                    for top cabinet spacing                     metal cabinets)
                                                                    (used on recessed
                                                                    bottom cabinet
                                                                    installations only)                         Power Cord Strap              1
                                                                                                                (plastic)
                               Saw (saber, hole or keyhole)


                                                                                              You will find the installation hardware contained in a
                                                                                              packet with the unit. Check to make sure you have
                                                                                              all these parts.
                                                                                              NOTE: Some extra parts are included.

                             Drill bits: 2", 3/16", 5/8"




                    12                                                                                                                        49-2000492 Rev. 0


                                     Installation Instructions




                                                                                                                     INSTALLATION INSTRUCTIONS
   PARTS INCLUDED                                         ADVANCE PLANNING
   ADDITIONAL PARTS                                       Duct Install Planning (for outside exhaust only)
                        PART                   QUANTITY   Ŷ8VHPHWDOGXFWZRUNRQO\
                                 Top Cabinet      1       Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHDSSOLDQFH
                                  Template                Ŷ3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV
                                                            To maximize the ventilation performance of the
                                                            vent system:
                    ≤
                         ≤
                             ≤



                                  Rear Wall       1         1.Minimize the duct run length and number of
                                  Template                    transitions and elbows.
                                                            2.Maintain a constant duct size.
                                  Owner's         1
                                  Manual                    3.Seal all joints with duct tape to prevent any
                                                              leaks.
                                                          NOTE: Flexible vent is not recommended. Flexible
                                  Exhaust         1       vent creates back pressure and air turbulence that
                                  Adaptor                 greatly reduces performance.
                                                          Ŷ0D[LPXPHTXLYDOHQWGXFWOHQJWKIRU&)0
                                                            150 foot.
                                  Charcoal        2
                                   Filter                 Ŷ,QVWDOODZDOOFDSRUURRIFDSZLWKGDPSHUDWWKH
                                                            exterior opening. Purchase the wall or roof cap
                                                            and any transition and length of duct needed in
                                                            advance.
                                                          Ŷ:KHQDSSOLFDEOHLQVWDOODQ\PDNHXS
                                                            (replacement) air system in accordance with local
                                                            building code requirements. Use makeup air kit
                                                            JXMUA8.
                                                            Vent system can terminate either through the roof
                                                            or the wall.
                                                                                        Roof Cap
                                                                                           Round Duct
                                                           Add Insulation
                                                            and/or Caulk


                                                                                                    Wall Cap
                                                              Add tape to joint

                                                                                                   Add Insulation
                                                               Kitchen Hub                         and/or Caulk




                                                          Recirculation Install Planning
                                                          Charcoal filters (included) are necessary for
                                                          recirculation installation.




49-2000492 Rev. 0                                                                                                   13


                                                             Installation Instructions
INSTALLATION INSTRUCTIONS



                            1. PLACEMENT OF THE MOUNTING PLATE
                             A REMOVING THE KITCHEN HUB                                B FINDING THE WALL STUDS
                                 FROM THE CARTON/REMOVING
                                 THE MOUNTING PLATE
                            Remove the packaging
                               CAUTION Wear gloves to protect against
                            sharp edges.                                                                Wall
                                                                                                        Studs
                            1. Open the box and fold back all four carton
                               flaps fully against the carton sides. Remove the
                               following items from the protective foam: charcoal          Center
                               filters, cord plug, damper, and screws. Do not
                               remove the foam protecting the front of the unit.
                            2. Carefully roll the unit and carton over onto the top
                               side. The unit should be resting in the foam.
                            3. Pull the carton up to remove.                          1. Find the studs, using one of the following methods:
                                                                                         A. Stud finder
                                                                                                              OR
                                                                            Carton       B. Use a hammer to tap lightly across the
                                                                                            mounting surface to find a solid sound. This will
                                                                                            indicate a stud location.
                                                                                      2. After locating the stud(s), find the center by probing
                                                                                         the wall with a small nail to find the edges of the
                                                                                         stud. Then place a mark halfway between the
                                                                                         edges. The center of any adjacent studs should be
                                     Foam                                                ƎRUƎIURPWKLVPDUN
                                                                                      3. Draw a line down the center of the stud.
                                                                                      IMPORTANT: The unit must be installed to at least
                            4. The mounting plate is attached to the back of          one wall stud.
                               the unit. Remove the two screws holding it to
                               the back. The plate will be used as the rear wall
                               template and for mounting the unit to the wall.




                                     Screws
                                                  Mounting Plate
                            5. Set the unit upright. Remove and properly discard
                               plastic bags and foam.




                   14                                                                                                                 49-2000492 Rev. 0


                                 Installation Instructions




                                                                                                                           INSTALLATION INSTRUCTIONS
1. PLACEMENT OF THE MOUNTING PLATE (Cont.)
     C DETERMINING MOUNTING PLATE LOCATION UNDER YOUR CABINET
    Plate Position – flat bottom cabinet                        Plate Position – recessed cabinet bottom



                                                                                                      Mounting Plate
                                                                                                      Tabs Touching the
                                           Mounting Plate                                             Back Frame of the
                                           Tabs Touching                                              Cabinet
                                           the Cabinet
                                           Bottom




                                                                                                         ƎWR&RRNWRS



                                               At least 30"


    Plate Position – cabinet with front overhang                 Your cabinets may have decorative trim that
                                                                 interferes with the unit installation. You may need
                                                                 to remove the decorative trim to install the unit
                                                                 properly and to make it level.
                                           Mounting Plate        THE KITCHEN HUB MUST BE LEVEL.
                                           with Tabs Below
                                           Cabinet Bottom the    Use a level to make sure the cabinet bottom is
                                           Same Distance as      level.
                                           the Front Overhang
                                           Depth                 If the cabinets have a front overhang, install the
                                                                 mounting plate down the same distance as the front
                                                                 overhang depth. This will keep the unit level.
                                                                 1. Measure the inside depth of the front overhang.
                                                                 2. Draw a horizontal line on the back wall an equal
                                                                    distance below the cabinet bottom as the inside
                                                                    depth of the front overhang.
                                                                 3. For this type of installation with front overhang,
                                                                    align the mounting tabs with this horizontal line,
                                                                    not touching the cabinet bottom as described in
                                                                    Step D.
                                              ƎWR&RRNWRS




49-2000492 Rev. 0                                                                                                         15


                                                             Installation Instructions
INSTALLATION INSTRUCTIONS



                            1. PLACEMENT OF THE MOUNTING PLATE (Cont.)
                             D ALIGNING THE MOUNTING PLATE




                                                                                       30”




                                                                                                                                Hole B
                                            Hole A                                             Draw a
                                                                                               Vertical Line
                                                                                               on Wall from
                                                                                               Center of Top
                                                                                               Cabinet




                                              Hole C                                                                        Hole D

                                                                   Area E

                                                                                                 Notch



                               CAUTION Wear gloves to protect against                          NOTE: Holes C and D are inside area E. If neither
                                                                                               C nor D is in a stud, find a stud somewhere in area
                            sharp edges.
                                                                                               E and draw a fifth circle to line up with the stud. It is
                            1. Draw a vertical line on the wall at the center of the           important to use at least one wood screw mounted
                               ƎZLGHVSDFH                                                 firmly in a stud to support the weight of the unit.
                            2. Use the mounting plate as the template for the rear             Set the mounting plate aside.
                               wall. Place the mounting plate on the wall, making
                               sure that the tabs are touching the bottom of the                WARNING Risk of electric shock. Can cause
                               cabinet or the level line drawn in Step C for cabinets
                               with front overhang. Line up the notch and center line        injury or death. Take care to not drill into electrical
                               on the mounting plate to the center line on the wall.         wiring inside walls or cabinets.

                            3. While holding the mounting plate with one hand,               4. Drill holes on the circles. If there is a stud, drill a
                               draw circles on the wall at holes A, B, C, and D (see            »ƎKROHIRUZRRGVFUHZV)RUKROHVWKDWGRQ¶WOLQH
                               illustration above/actual plate marked with arrows).             XSZLWKDVWXGGULOOD»ƎKROHIRUWRJJOHEROWV
                               Four holes must be used for mounting.
                                                                                             NOTE: DO NOT MOUNT THE PLATE AT THIS TIME.




                   16                                                                                                                          49-2000492 Rev. 0


                                  Installation Instructions




                                                                                                                INSTALLATION INSTRUCTIONS
2. INSTALLATION TYPES                                 (Choose A, B or C)

   This appliance is designed for adaptation to the      NOTE: Select the type of ventilation required for
   following 3 types of ventilation:                     your installation and proceed to that section. This
   A. Outside Top Exhaust (Vertical Duct)                unit is shipped assembled for outside top exhaust.

   B. Recirculating (Non-Vented Ductless)
   C. Outside Back Exhaust (Horizontal Duct)


     A OUTSIDE TOP EXHAUST                                B RECIRCULATING
             (VERTICAL DUCT)                                  (NON-VENTED DUCTLESS)
             See page 18.                                     See page 21.




     C OUTSIDE BACK EXHAUST
             (HORIZONTAL DUCT)
             See page 25.




49-2000492 Rev. 0                                                                                              17


                                                                  Installation Instructions
INSTALLATION INSTRUCTIONS



                            A. OUTSIDE TOP EXHAUST                                     (Vertical Duct)

                            INSTALLATION OVERVIEW
                            A1. Attach Mounting Plate to Wall
                            A2. Prepare Top Cabinet
                            A3. Adjust Blower Exhaust
                            A4. Install Exhaust Adaptor
                            A5. Mount the Kitchen Hub
                            A6. Connect Ductwork
                            A7. Finalize Installation



                             A1 ATTACH THE MOUNTING PLATE                               A1 ATTACH THE MOUNTING PLATE
                                  TO THE WALL                                                 TO THE WALL (Cont.)
                                                          B
                                    A                                                      CAUTION Be careful to avoid pinching
                                                                                        fingers between the back of the mounting plate
                                                                                        and the wall.
                                                                                        4. Tighten all bolts. Pull the plate away from the wall
                                                                                           to help tighten the bolts.


                                           C                  D
                                                                                        A2 USE TOP CABINET TEMPLATE
                            Attach the plate to the wall using toggle bolts. At               FOR PREPARATION OF TOP
                            least one wood screw must be used to attach the
                            plate to a wall stud. Recommended locations on the
                                                                                              CABINET
                            mounting plate are indicated by A, B, C and D.              You need to drill holes for the top support screws
                            1. Remove the toggle wings from the bolts.                  and a hole large enough for the power cord to fit
                            2. Insert the bolts into the mounting plate through         through, and a cutout large enough for the exhaust
                               the holes designated to go into drywall and              adaptor.
                               UHDWWDFKWKHWRJJOHZLQJVWR»ƎRQWRHDFKEROW
                              To use toggle bolts:
                                                 Spacing for Toggles More
                                                 Than Wall Thickness

                             Mounting       Toggle Wings
                                Plate              Toggle
                                                   Bolt




                                               Wall
                                                        Mounting Plate   Bolt End

                            3. Place the mounting plate against the wall and            • Read the instructions on the TOP CABINET
                               insert the toggle wings into the holes in the wall to      TEMPLATE.
                               mount the plate.                                         • Tape it underneath the top cabinet.
                            NOTE: Before tightening toggle bolts and wood               • Drill the holes, following the instructions on the
                            screw, make sure the tabs on the mounting plate               TOP CABINET TEMPLATE.
                            touch the bottom of the cabinet when pushed
                            flush against the wall and that the plate is properly          CAUTION Wear safety goggles when
                            centered under the cabinet.                                 drilling holes in the cabinet bottom.

                   18                                                                                                                   49-2000492 Rev. 0


                                  Installation Instructions




                                                                                                                  INSTALLATION INSTRUCTIONS
A. OUTSIDE TOP EXHAUST                                     (Vertical Duct) (Cont.)

     A3 ADJUST BLOWER EXHAUST                               A4 ASSEMBLE AND INSTALL
   The unit is shipped in the top exhaust configuration.          ADAPTOR
   If configuration is not in the top exhaust direction,              Screws
   follow the steps below.
         CAUTION Wear gloves to protect against                                                         Damper

   sharp edges.
   1. Remove damper mounting plate and diverter.
   2. Remove diverter from angled position and reinsert
      vertically as shown.
   3. Reattach the damper mounting plate with opening
      on top of unit as shown.




                                                            1. Remove 3 screws shown above. Position the
                                                               damper on top of the damper mounting plate and
                                                               secure with removed screws.
                                                            2. Remove the tape from the damper. Make sure
                                                               that the damper pivots easily before mounting
                                                               the unit.
                                                              You will need to make adjustments to assure
                                                              proper alignment with your house exhaust duct
                                                              after the unit is installed.




49-2000492 Rev. 0                                                                                                19


                                                              Installation Instructions
INSTALLATION INSTRUCTIONS



                            A. OUTSIDE TOP EXHAUST                                  (Vertical Duct) (Cont.)

                             A5 MOUNT THE KITCHEN HUB                                A5 MOUNT THE KITCHEN HUB
                                                                                            (Cont.)
                                                                                     3. Insert 2 self-aligning screws(1/4" - 28 x 3-1/4")
                                                                                        through top-center cabinet hole. Turn two full
                                                                                        turns on each screw.
                                                                                    Cabinet Front
                                                                                                Cabinet Bottom Shelf
                                                                                                                       Filler Block
                               CAUTION To avoid the risk of personal
                                                                                                                                        This
                            injury (back injury or other injuries due to                                                   Equivalent   distance
                            excessive weight of the unit) or property                                                      to Depth     can NOT
                                                                                                                           of Cabinet   exceed 2”
                            damage, you will need two people to install this                                               Recess       to ensure
                            product.                                                                                                    proper
                                                                                                                                        installation
                            IMPORTANT: Do not put any pressure on front                                        Self-Aligning Screw
                            screen during installation.
                                                                                                    Unit Top
                               WARNING Risk of Electric Shock. Can
                                                                                     4. Tighten the 2 screws to the top of the unit. (While
                            cause injury or death: If installing unit with metal        tightening screws, hold the unit in place against
                            cabinets, cover the edge of the power supply                the wall and the top cabinet.)
                            cord hole with the nylon grommet in hardware
                            bag.
                            IMPORTANT: If filler blocks are not used, case
                            damage may occur from overtightening screws.
                            NOTE: When mounting the unit, thread power cord
                            through hole in bottom of top cabinet. Keep it tight
                            throughout Steps 1–3. Do not pinch cord or lift unit
                            by pulling cord.
                            1. Lift unit, tilt it forward, and hook slots at back
                               bottom edge onto four lower tabs of mounting
                               plate.




                            2. Rotate front of unit up against cabinet bottom.




                    20                                                                                                                  49-2000492 Rev. 0


                                  Installation Instructions




                                                                                INSTALLATION INSTRUCTIONS
A. OUTSIDE TOP EXHAUST                               (Vertical Duct) (Cont.)

     A6 CONNECTING DUCT WORK
   1. Extend the house duct down to connect to the
      exhaust adaptor.
   2. Seal exhaust duct joints using duct tape.




    A7 FINALIZE INSTALLATION
              Plug in the unit.




49-2000492 Rev. 0                                                              21


                                                             Installation Instructions
INSTALLATION INSTRUCTIONS



                            B. RECIRCULATING                               (Non-Vented Ductless)

                            INSTALLATION OVERVIEW
                            B1. Attach Mounting Plate to Wall
                            B2. Prepare Top Cabinet
                            B3. Adjust Blower Exhaust
                            B4. Mount the Kitchen Hub
                            B5. Filters
                            B6. Finalize Installation




                             B1 ATTACH THE MOUNTING PLATE                              B1 ATTACH THE MOUNTING PLATE
                                  TO THE WALL                                                TO THE WALL (Cont.)
                                                                                          CAUTION Be careful to avoid pinching
                                                                                       fingers between the back of the mounting plate
                                                                                       and the wall.
                                                                                       4. Tighten all bolts. Pull the plate away from the wall
                                                                                          to help tighten the bolts.




                            Attach the plate to the wall using toggle bolts. At        B2 USE TOP CABINET TEMPLATE
                            least one wood screw must be used to attach the                  FOR PREPARATION OF TOP
                            plate to a wall stud.                                            CABINET
                            1. Remove the toggle wings from the bolts.
                                                                                       You need to drill holes for the top support screws
                            2. Insert the bolts into the mounting plate through        and a hole large enough for the power cord to fit
                               the holes designated to go into drywall and             through.
                               UHDWWDFKWKHWRJJOHZLQJVWR»ƎRQWRHDFKEROW
                              To use toggle bolts:
                                                Spacing for Toggles More
                                                Than Wall Thickness
                                             Toggle Wings
                            Mounting
                                                 Toggle                                • Read the instructions on the TOP CABINET
                               Plate
                                                 Bolt                                    TEMPLATE.
                                                                                       • Tape it underneath the top cabinet.
                                                                                       • Drill the holes, following the instructions on the
                                             Wall                                        TOP CABINET TEMPLATE.
                                                                   Bolt End
                                                                                          CAUTION Wear safety goggles when
                            3. Place the mounting plate against the wall and
                               insert the toggle wings into the holes in the wall to   drilling holes in the cabinet bottom.
                               mount the plate.
                            NOTE: Before tightening toggle bolts and wood
                            screw, make sure the tabs on the mounting plate
                            touch the bottom of the cabinet or the horizontal
                            level line when pushed flush against the wall and
                            that the plate is properly centered under the cabinet.


                   22                                                                                                                  49-2000492 Rev. 0


            Installation Instructions




                                                                                                                    INSTALLATION INSTRUCTIONS
B. RECIRCULATING (Non-Vented Ductless)
     B3 ADJUST BLOWER EXHAUST                              B4 MOUNT THE KITCHEN HUB
   The unit is shipped in the top venting mode exhaust
   configuration. The vertical deflector plate should be
   repositioned to the angled position.
   1. Remove damper mounting plate and diverter.




                                                              CAUTION To avoid the risk of personal
                                                           injury (back injury or other injuries due to
                                                           excessive weight of the unit) or property
                                                           damage, you will need two people to install this
                                                           product.
                                                           IMPORTANT: Do not put any pressure on front
                                                           screen during installation.
                                                              WARNING Risk of Electric Shock. Can
                                                           cause injury or death: If installing unit with metal
                                                           cabinets, cover the edge of the power supply
                                                           cord hole with the nylon grommet in hardware
   2. Install diverter in angled position and reinstall    bag.
      damper mounting plate.                               NOTE: When mounting the appliance, thread power
                                                           cord through hole in bottom of top cabinet. Keep it
                                                           tight throughout Steps 1–3. Do not pinch cord or lift
                                                           unit by pulling cord.
                                                           1. Lift appliance, tilt it forward, and hook slots
                                                              at back bottom edge onto four lower tabs of
                                                              mounting plate.




                                                           2. Rotate front of appliance up against cabinet
                                                              bottom.




49-2000492 Rev. 0                                                                                                  23


                                                                 Installation Instructions
INSTALLATION INSTRUCTIONS



                            B. RECIRCULATING                                    (Non-Vented Ductless) (Cont.)

                              B4 MOUNT THE KITCHEN HUB                                          B5 FILTERS
                                    (Cont.)                                                     1. Remove grease filter and install a charcoal filter
                             ,QVHUWVHOIDOLJQLQJVFUHZV »Ǝ[                  on each side of the motor as shown below.
                                through outer top cabinet holes. Turn two full
                                turns on each screw.
                            Cabinet Front
                                        Cabinet Bottom Shelf
                                                               Filler Block

                                                                                 This                                              Charcoal
                                                                   Equivalent    distance                                          Filter Mount
                                                                   to Depth      can NOT
                                                                   of Cabinet    exceed 2”
                                                                   Recess        to ensure
                                                                                 proper
                                                                                 installation
                                                       Self-Aligning Screw

                                            Unit Top


                             4. Tighten the two screws to the top of the unit.
                                (While tightening screws, hold the unit in place
                                against the wall and the top cabinet.)




                                                                                                B6 FINALIZE INSTALLATION
                                                                                                       Plug in the unit.




                   24                                                                                                                             49-2000492 Rev. 0


                                    Installation Instructions




                                                                                                                           INSTALLATION INSTRUCTIONS
C. OUTSIDE BACK EXHAUST                                          (Horizontal Duct)

   INSTALLATION OVERVIEW
   C1. Prepare Rear Wall
   C2. Attach Mounting Plate to Wall
   C3. Prepare Top Cabinet
   C4. Adjust Blower Exhaust
   C5. Mount the Kitchen Hub
   C6. Finalize Installation



     C1 PREPARING THE REAR WALL                                C2 ATTACH THE MOUNTING PLATE
              FOR OUTSIDE BACK EXHAUST                               TO THE WALL (Cont.)
   You need to cut an opening in the rear wall for             1. Remove the toggle wings from the bolts.
   outside exhaust.
                                                               2. Insert the bolts into the mounting plate through the
                                                                  holes designated to go into drywall and reattach the
                                                                  WRJJOHZLQJVWR»ƎRQWRHDFKEROW
                                                                 To use toggle bolts:
                                                                                  Spacing for Toggles More
                                                                                  Than Wall Thickness
                                                                              Toggle Wings
                                                               Mounting
                                                                  Plate            Toggle
                                                                                   Bolt



                                                                                                        Bolt
                                                                                Wall                    End

   • Read the instructions on the REAR WALL                    3. Place the mounting plate against the wall and insert
     TEMPLATE.                                                    the toggle wings into the holes in the wall to mount
                                                                  the plate.
   • Tape it to the rear wall, lining up with the holes
     previously drilled for holes A and B in the mounting      NOTE: Before tightening toggle bolts and wood
     plate.                                                    screw, make sure the tabs on the mounting plate
                                                               touch the bottom of the cabinet when pushed flush
   • Cut the opening, following the instructions of the
                                                               against the wall and that the plate is properly centered
     REAR WALL TEMPLATE.
                                                               under the cabinet.
                                                                  CAUTION Be careful to avoid pinching fingers
     C2 ATTACH THE MOUNTING PLATE                              between the back of the mounting plate and the wall.
              TO THE WALL                                      4. Tighten all bolts. Pull the plate away from the wall
                                                                  to help tighten the bolts.




   Attach the plate to the wall using toggle bolts. At least
   one wood screw must be used to attach the plate to
   a wall stud.

49-2000492 Rev. 0                                                                                                         25


                                                            Installation Instructions
INSTALLATION INSTRUCTIONS



                            C. OUTSIDE BACK EXHAUST                                      (Horizontal Duct) (Cont.)

                             C3 USE TOP CABINET TEMPLATE                               C4 ADJUST BLOWER EXHAUST
                                  FOR PREPARATION OF TOP                               The unit is shipped in the top exhaust configuration.
                                  CABINET                                              To adjust the unit to back exhaust remove damper
                                                                                       mounting plate and reposition such that opening is
                            You need to drill holes for the top support screws         in the back of the unit.
                            and a hole large enough for the power cord to fit
                            through.                                                      CAUTION Wear gloves to protect against
                                                                                       sharp edges.
                                                                                       1. Remove 3 screws as shown and save.
                                                                                       2. Remove damper mounting plate by removing
                                                                                          screws.




                            • Read the instructions on the TOP CABINET
                              TEMPLATE.
                            • Tape it underneath the top cabinet.
                            • Drill the holes, following the instructions on the TOP
                              CABINET TEMPLATE.                                        3. Reposition damper mounting plate such that
                               CAUTION Wear safety goggles when                           opening is in the back of the unit.
                                                                                       4. Reattach screws.
                            drilling holes in the cabinet bottom.


                                                                                       C5 ASSEMBLE AND INSTALL
                                                                                             ADAPTER
                                                                                       1. Remove the tape from the damper. Make sure
                                                                                          that the damper pivots easily before mounting
                                                                                          the unit.
                                                                                         You will need to make adjustments to assure
                                                                                         proper alignment with your house exhaust duct
                                                                                         after the unit is installed.
                                                                                       2. Position the unit damper to back of the unit and
                                                                                          secure it with the screws that were removed.
                                                                                          NOTE: Damper must hinge at the top as shown
                                                                                          below.




                    26                                                                                                               49-2000492 Rev. 0


                                      Installation Instructions




                                                                                                                                  INSTALLATION INSTRUCTIONS
C. OUTSIDE BACK EXHAUST                                             (Horizontal Duct) (Cont.)

     C6 MOUNT THE KITCHEN HUB                                     C6 MOUNT THE KITCHEN HUB
                                                                         (Cont.)
         CAUTION To avoid the
                                                                  2. Rotate front of unit up against cabinet bottom.
   risk of personal injury (back
   injury or other injuries due to                                3. Insert 2 self-aligning screws (1/4”-28 x 3-1/4”)
   excessive weight of the unit)                                     through top-center cabinet hole. Turn two full
   or property damage, you will                                      turns on each screw.
   need two people to install                                       Cabinet Front
   this product.                                                              Cabinet Bottom Shelf
                                                                                                 Filler Block
   IMPORTANT: Do not put any pressure on front
   screen during installation.                                                                                    This
                                                                                                     Equivalent   distance
                                                                                                     to Depth     can NOT
         WARNING Risk of Electric Shock. Can                                                         of Cabinet   exceed 2”
                                                                                                     Recess       to ensure
   cause injury or death: If installing unit with metal                                                           proper
                                                                                                                  installation
   cabinets, cover the edge of the power supply                                            Self-Aligning Screw
   cord hole with the nylon grommet in hardware
                                                                               Unit Top
   bag.
                                                                  4. Tighten the 2 screws to the top of the unit. (While
   IMPORTANT: If filler blocks are not used, case
                                                                     tightening screws, hold the unit in place against
   damage may occur from overtightening screws.
                                                                     the wall and the top cabinet.)
   NOTE: When mounting the unit, thread power cord
   through hole in bottom of top cabinet. Keep it tight
   throughout Steps 1–3. Do not pinch cord or lift unit
   by pulling cord.
   1. Lift unit, tilt it forward, and hook slots at back bottom
      edge onto four lower tabs of mounting plate.




                                                                  C7 FINALIZE INSTALLATION
                                                                         Plug in the unit.




49-2000492 Rev. 0                                                                                                                27


                                                       Installation Instructions
TROUBLESHOOTING TIPS



                       MAKE UP AIR TECHNOLOGY
                       Note to Installers and Inspectors: This product comes equipped with a simple installation feature that limits
                       maximum CFM levels in order to comply with certain local codes or regulations. This installation method may not
                       be necessary for all installations, please refer to your local codes for further guidelines.
                          CAUTION Appliance must be disconnected from main power prior to performing the conversion
                       instructions listed below. Failure to do so could result in personal injury or damage to the product.
                       To modify unit (if needed for local codes):
                       390CFM or 290CFM
                       By design, the maximum blower speed is greater than
                       400 CFM. For local codes requiring reduced CFM,
                       modify the wiring as described below:
                       1. Remove the filters.
                       2. Remove the control board box cover.
                       3. Locate the motor harness plugged into the control
                          board.
                       4. A - For a maximum of 390 CFM
                              Unit can operate with 4 speeds
                              (Low, Medium, High, Boost).
                              1. Disconnect the connector of the blue wire
                                 from the red wire.
                                                                                                                       Control Box Cover
                              2. Connect the 2 red wires together.
                          B - For a maximum of 290 CFM
                              Unit can operate with 3 speeds
                              (Low, Medium, High).
                              Disconnect the connector of the blue wire from                                                 Control Box
                              the red wire.
                              NOTE: Boost speed will be disabled. Unit will
                                                                                                                         Motor Pin
                              operate Low, Med & High only.
                       5. Reattach the control board box cover and install
                          Filters, see Filters section.
                       Note to Inspectors: To verify this product was
                       installed in either configuration, check motor wiring
                       connections as described above.
                                                                                   Motor Harness
                                                                                   Connector




                                                                                                             Red




                                                                                                          Blue
                                                                                                                 Red




                                                                                                             Motor Harness




                28                                                                                                                         49-2000492 Rev. 0


Troubleshooting tips ... Before you call for service




                                                                                                                                       TROUBLESHOOTING TIPS
Save time and money! Review the charts on the following pages first and you may not need to call for service.

  Problem                   Possible Cause                                What To Do
  Fan/Light does not        A house fuse may be blown or a circuit        Replace fuse or reset circuit breaker.
  operate when button is    breaker tripped.
  turned ON
  Loud or abnormal          Wrong duct size used in installation.         This unit requires 8” ducting to perform optimally.
  airflow noise                                                           Using smaller duct pipe will cause reduced venting.
                                                                          Minimize the duct run length and number of transitions
                                                                          and elbows. GE Appliances service technicians cannot
                                                                          correct this issue if installed improperly.
  Fan fails to circulate    Obstructions in duct work.                    Make sure nothing is blocking the vent. Make sure
  air or moves air slower                                                 your wall or roof cap has a blade or door.
  than normal and/or        Damper blade on wall or roof cap may          Make sure damper swings freely. Damper blades may
  fan is making loud or     not be open.                                  flip over and will not fully open when this happens.
  abnormal airflow noise                                                  Adjust to original position.
                            Metal grease filter and charcoal filter (if   Clean the metal grease filter and replace charcoal filter
                            present) may be dirty.                        (if present). See Care and Cleaning.
                            Insufficient makeup (replacement) air         Sufficient makeup (replacement) air is required for
                                                                          exhausting appliances to operate to rating. Check with
                                                                          local building codes, which may require or strongly
                                                                          advise the use of makeup air. Visit GEAppliances.com
                                                                          for available makeup air solutions.
  Fan keeps going off       The motor is probably overheating and         Check to be sure the filters are clean. If off and on
  and on                    turning itself off. This can be harmful to    cycling continues, call for service.
                            the motor.




49-2000492 Rev. 0                                                                                                                     29


                                                            GE Appliances Limited Warranty
LIMITED WARRANTY


                                                            GEAppliances.com
                                                            All warranty service is provided by our Factory Service Centers, or an authorized Customer Care® technician. To
                                                            schedule service online, visit us at geappliances.com/service_and_support/, or call GE Appliances at 800.GE.CARES
                                                            (800.432.2737). Please have your serial number and your model number available when calling for service.
                                                            Servicing your appliance may require the use of the onboard data port for diagnostics. This gives a GE Appliances factory
                                                            service technician the ability to quickly diagnose any issues with your appliance and helps GE Appliances improve its
                                                            products by providing GE Appliances with information on your appliance. If you do not want your appliance data to be
                                                            sent to GE Appliances, please advise your technician not to submit the data to GE Appliances at the time of service.
                                                            For the period of       GE Appliances will replace
                                                            One year                Any part of the cooking product which fails due to a defect in materials or workmanship.
                                                            From the date           During this limited one-year warranty, GE Appliances will provide, free of charge, all labor
                                                            of the original         and related service costs to replace the defective part.
                                                            purchase

                                                            What GE Appliances will not cover:
                                                            Ŷ Service trips to your home to teach you how to use            Ŷ Damage to finish, such as surface rust, tarnish, or small
                                                                the product.                                                   blemishes not reported within 48 hours of delivery.
                                                            Ŷ   Improper installation, delivery, or maintenance.            Ŷ Incidental or consequential damage caused by
                                                            Ŷ   Failure of the product if it is abused, misused,               possible defects with this appliance.
                                                                modified, or used for other than the intended purpose       Ŷ Damage caused after delivery.
                                                                or used commercially.                                       Ŷ Product not accessible to provide required service.
                                                            Ŷ   Replacement of house fuses or resetting of circuit          Ŷ Service to repair or replace light bulbs, except for LED
                                                                breakers.                                                      lamps.
                                                            Ŷ   Damage to the product caused by accident, fire,
                                                                floods, or acts of God.

                                                                EXCLUSION OF IMPLIED WARRANTIES
                                                                Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties,
                                                                including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or
                                                                the shortest period allowed by law.
 Staple your receipt here. Proof of the original purchase




                                                            This limited warranty is extended to the original purchaser and any succeeding owner for products purchased for home
 date is needed to obtain service under the warranty.




                                                            use within the USA. If the product is located in an area where service by a GE Appliances Authorized Servicer is not
                                                            available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE
                                                            Appliances Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service calls to
                                                            your home.
                                                            Some states do not allow the exclusion or limitation of incidental or consequential damages. This limited warranty
                                                            gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your
                                                            legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
                                                                                             Warrantor: GE Appliances, a Haier company
                                                                                                        Louisville, KY 40225

                                                            Extended Warranties: Purchase a GE Appliances extended warranty and learn about special discounts that are
                                                            available while your warranty is still in effect. You can purchase it online anytime at
                                                                               geappliances.com/service_and_support/shop-for-extended-service-plans.htm
                                                            or call 800.626.2224 during normal business hours. GE Appliances Service will still be there after your warranty expires.




                                         30                                                                                                                                   49-2000492 Rev. 0


Accessories




                                                        ACCESSORIES
Looking For Something More?
GE Appliances offers a variety of accessories to
improve your cooking and maintenance experiences!
Refer to the Consumer Support page for phone numbers
and website information.
The following products and more are available:

Parts
    Make-up Air Kit
    Charcoal Filter
    Bump Out Kit
    Filler Kit

Cleaning Supplies
    CitruShine™ Stainless Steel Wipes
    CERAMA BRYTE® Stainless Steel Appliance Cleaner
    Bar Keepers Friend Soft Cleanser™




49-2000492 Rev. 0                                      31


                   Consumer Support
CONSUMER SUPPORT


                   GE Appliances Website
                   Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day
                   of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support
                   services designed for your convenience. In the US: GEAppliances.com


                   Register Your Appliance
                   Register your new appliance on-line at your convenience! Timely product registration will allow for enhanced
                   communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the
                   pre-printed registration card included in the packing material. In the US: GEAppliances.com/register


                   Schedule Service
                   Expert GE Appliances repair service is only one step away from your door. Get on-line and schedule your service at
                   your convenience any day of the year. In the US: GEAppliances.com/service
                   or call 800.432.2737 during normal business hours.


                   Extended Warranties
                   Purchase a GE Appliances extended warranty and learn about special discounts that are available while your
                   warranty is still in effect. You can purchase it on-line anytime. GE Appliances Services will still be there after your
                   warranty expires. In the US: GEAppliances.com/extended-warranty
                   or call 800.626.2224 during normal business hours.


                   Remote Connectivity
                   For assistance with wireless network connectivity (for models with remote enable),
                   visit our website at GEAppliances.com/connect or call 800.220.6899 in the US.


                   Parts and Accessories
                   Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes
                   (VISA, MasterCard and Discover cards are accepted). Order on-line today 24 hours every day.
                   In the US: GEApplianceparts.com or by phone at 877.959.8688 during normal business hours.
                   Instructions contained in this manual cover procedures to be performed by any user. Other servicing
                   generally should be referred to qualified service personnel. Caution must be exercised, since improper
                   servicing may cause unsafe operation.


                   Contact Us
                   If you are not satisfied with the service you receive from GE Appliances, contact us on our Website with all the
                   details including your phone number, or write to:
                   In the US: General Manager, Customer Relations | GE Appliances, Appliance Park | Louisville, KY 40225
                   GEAppliances.com/contact




                                                                       Printed in China

            32                                                                                                                     49-2000492 Rev. 0



Document Created: 2019-02-22 16:59:26
Document Modified: 2019-02-22 16:59:26

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC