Test Report for PCB_part 24

FCC ID: YR8ES710

Test Report

Download: PDF
FCCID_2566555

Report No.: RXA1502-0023RF02R2                                Page 1of 33




                                              TESTING
                                              No. L2264




                                 Part 24
                 TEST REPORT
                Product Name GPS Tracker

                Model Name       ES710

                Brand Name       eSky

                FCC ID           YR8ES710

                Applicant        eSky wireless Inc.

                Manufacturer     ASIATELCO TECHNOLOGIES CO.

                Date of issue    March 20, 2015




         TA Technology (Shanghai) Co., Ltd.


                         TA Technology (Shanghai) Co., Ltd.
                                    Test Report
Report No.: RXA1502-0023RF02R2                                                           Page 2of 33


                                GENERAL SUMMARY

               FCC CFR47 Part 2    (2013)    Frequency Allocations And Radio Treaty Matters;
               General Rules And Regulations

               FCC CFR47 Part 24E (2013)        Personal Communications Services
Reference
Standard(s)    ANSI/TIA-603-C(2004)   Land mobile FM or PM Communications Equipment
               Measurements and Performance Standards.

               KDB 971168 D01 Power Meas License Digital Systems v02r02                     Measurement
               Guidance for Certification of Licensed Digital Transmitters




               This fixed wireless equipment has been measured in all cases requested by the
               relevant standards. Test results in Chapter 2 of this test report are below limits specified
               in the relevant standards.
Conclusion
               General Judgment:     Pass




Comment        The test result only responds to the measured sample.




Approved by                  Revised by                           Performed by
              Kai Xu                      Lingling Kang                                Changxu Wan
              Director                      RF Manager                                  RF Engineer


                                      TA Technology (Shanghai) Co., Ltd.
                                                 Test Report
Report No.: RXA1502-0023RF02R2                                                                                                   Page 3of 33




                                                 TABLE OF CONTENT


1.     General Information ..................................................................................................................... 4
     1.1. Notes of the test report .........................................................................................................4
     1.2. Testing laboratory .................................................................................................................5
     1.3. Applicant Information ............................................................................................................5
     1.4. Manufacturer Information ......................................................................................................5
     1.5. Information of EUT ................................................................................................................6
     1.6. Test Date ..............................................................................................................................6
2.     Test Information ........................................................................................................................... 7
     2.1. Summary of test results ........................................................................................................7
     2.2. RF Power Output ..................................................................................................................7
     2.3. Effective Isotropic Radiated Power .....................................................................................10
     2.4. Occupied Bandwidth ...........................................................................................................12
     2.5. Band Edge Compliance ......................................................................................................15
     2.6. Peak-to-Average Power Ratio (PAPR) ...............................................................................18
     2.7. Frequency Stability .............................................................................................................21
     2.8. Spurious Emissions at Antenna Terminals .........................................................................23
     2.8    Radiates Spurious Emission ...............................................................................................27
3.      Main Test Instruments ................................................................................................................ 31
ANNEX A: EUT Appearance and Test Setup ..................................................................................... 32
 A.1   EUT Appearance ................................................................................................................32
 A.2   Test Setup ...........................................................................................................................33


                           TA Technology (Shanghai) Co., Ltd.
                                      Test Report
Report No.: RXA1502-0023RF02R2                                                                 Page 4of 33



1. General Information



1.1. Notes of the test report

TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS), and accreditation number: L2264.

TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications
Commission list of test facilities recognized to perform electromagnetic emissions measurements.
The site recognition number is 428261.

TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform
electromagnetic emission measurement. The site recognition number is 8510A.

TA Technology (Shanghai) Co., Ltd. guarantees the reliability of the data presented in this test
report, which is the results of measurements and tests performed for the items under test on the date
and under the conditions stated in this test report and is based on the knowledge and technical
facilities available at TA Technology (Shanghai) Co., Ltd. at the time of execution of the test.

TA Technology (Shanghai) Co., Ltd. is liable to the client for the maintenance by its personnel of the
confidentiality of all information related to the items under test and the results of the test. The sample
under test was selected by the Client.This report only refers to the item that has undergone the test.

This report standalone dose not constitute or imply by its own an approval of the product by the
certification Bodies or competent Authorities. This report cannot be used partially or in full for publicity
and/or promotional purposes without previous written approval of TA Technology (Shanghai) Co.,
Ltd. and the Accreditation Bodies, if it applies.

If the electrical report is inconsistent with the printed one, it should be subject to the latter.


                       TA Technology (Shanghai) Co., Ltd.
                                  Test Report
Report No.: RXA1502-0023RF02R2                                        Page 5of 33



1.2. Testing laboratory

Company:      TA Technology (Shanghai) Co., Ltd.
Address:      No.145, Jintang Rd, Tangzhen Industry Park, Pudong
City:         Shanghai
Post code:    201201
Country:      P. R. China

Contact:      Xu Kai
Telephone:    +86-021-50791141/2/3
Fax:          +86-021-50791141/2/3-8000
Website:      http://www.ta-shanghai.com
E-mail:       xukai@ta-shanghai.com



1.3. Applicant Information

Company:      eSky wireless Inc.
              A311#,258,Road Ren'ai Suzhou 215021
Address:
              PR.China



1.4. Manufacturer Information

Company:      AsiaTelco Technologies Co.
              #289 Bisheng Road, Building-8, 3F, Zhangjiang Hi-Tech Park, Pudong,
Address:
              Shanghai-201204, China


                         TA Technology (Shanghai) Co., Ltd.
                                    Test Report
 Report No.: RXA1502-0023RF02R2                                                    Page 6of 33




 1.5. Information of EUT

 General information

MEID:                              A100003230B9D6

Hardware Version:                  P1

Software Version:                  1.1.67T

Antenna Type:                      Internal Antenna

Device Operating Configurations:

Test Mode(s):                      CDMA PCS:

Support mode:                      1x RTT

Test Modulation:                   QPSK

Maximum E.I.R.P.                   22.36 dBm

Rated Power Supply Voltage:        12V

Extreme Voltage:                   Minimum: 6V        Maximum: 40V

Extreme Temperature:               Lowest: -40°C       Highest: +80°C
Test Channel:
                                   25 - 600 - 1175            (CDMA PCS)      (tested)
(Low - Middle - High)
                                          Band                Tx (MHz)            Rx (MHz)
Operating Frequency Range(s)
                                        CDMA PCS          1851.25 ~ 1908.75   1931.25 ~ 1988.75




 1.6. Test Date

 The test is performed from February 10, 2015 to February 12, 2015.


                        TA Technology (Shanghai) Co., Ltd.
                                   Test Report
Report No.: RXA1502-0023RF02R2                                                   Page 7of 33



2. Test Information

2.1. Summary of test results

Number     Test Case                                   Clause in FCC rules          Verdict

   1       RF power output                             2.1046                        PASS

   2       Effective Isotropic Radiated power          24.232                        PASS

   3       Occupied Bandwidth                          2.1049                        PASS

   4       Band Edge Compliance                        24.238                        PASS

   5       Peak-to-Average Power Ratio                 KDB 971168 D01(5.7)           PASS

   6       Frequency Stability                         2.1055 / 24.235               PASS

   7       Spurious Emissions at Antenna Terminals     2.1051 / 24.238               PASS

   8       Radiates Spurious Emission                  2.1053 / 24.238               PASS
PASS: The EUT complies with the essential requirements in the standard.
FAIL: The EUT does not comply with the essential requirements in the standard.


                        TA Technology (Shanghai) Co., Ltd.
                                   Test Report
Report No.: RXA1502-0023RF02R2                                                        Page 8of 33



2.2. RF Power Output

Ambient condition

             Temperature           Relative humidity                  Pressure

             23°C ~25°C                45%~50%                       101.5kPa



Methods of Measurement

During the process of the testing, The EUT is controlled by the Base Station Simulator to ensure max
power transmission and proper modulation.

Test Setup




The loss between RF output port of the EUT and the input port of the tester has been taken into
consideration.

Limits

No specific RF power output requirements in part 2.1046.



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 0.4 dB.


                       TA Technology (Shanghai) Co., Ltd.
                                  Test Report
Report No.: RXA1502-0023RF02R2                                                     Page 9of 33

Test Results



                                                        Conducted Power(dBm)
               CDMA PCS                      Channel 25          Channel 600      Channel 1175
                                            1851.25 (MHz)        1880 (MHz)       1908.75 (MHz)
                          +F-SCH                23.18               23.12             22.62
     SO32
                          +SCH                  22.96               22.74             22.64
Note:
1) The maximum RF Output Power numbers are marks in bold.
2) The following testing is set to +F-SCH based on the maximum RF Output Power.


                        TA Technology (Shanghai) Co., Ltd.
                                   Test Report
Report No.: RXA1502-0023RF02R2                                                      Page 10of 33



2.3. Effective Isotropic Radiated Power

Ambient condition

                     Temperature                              Relative humidity

                     21°C ~25°C                                  40%~60%

Methods of Measurement

The measurement procedures in TIA- 603C are used.
1. The EUT was placed on a turntable with 1.5 meter height in a fully anechoic chamber.
2. The EUT was set at 3 meters from the receiving antenna, which was mounted on the antenna
tower.
3. GSM operating modes: Set RBW= 1MHz, VBW= 3MHz, RMS detector over burst;
UMTS operating modes: Set RBW= 100 KHz, VBW= 300 KHz, RMS detector over frame, and
use channel power option with bandwidth=5MHz, per section 4.0 of KDB 971168 D01.
4. The table was rotated 360 degrees to determine the position of the highest radiated power.
5. The height of the receiving antenna is adjusted to look for the maximum ERP/EIRP.
6. Taking the record of maximum ERP/EIRP.
7. A dipole antenna was substituted in place of the EUT and was driven by a signal generator.
8. The conducted power at the terminal of the dipole antenna is measured.
9. Repeat step 3 to step 5 to get the maximum ERP/EIRP of the substitution antenna.
10. ERP/EIRP = Ps + Et – Es + Gs = Ps + Rt – Rs + Gs
Ps (dBm):Input power to substitution antenna.
Gs (dBi or dBd):Substitution antenna Gain.
Et = Rt + AF
Es = Rs + AF
AF (dB/m):Receive antenna factor
Rt:The highest received signal in spectrum analyzer for EUT.
Rs:The highest received signal in spectrum analyzer for substitution antenna.
Test Setup


                          TA Technology (Shanghai) Co., Ltd.
                                     Test Report
Report No.: RXA1502-0023RF02R2                                                         Page 11of 33

Limits

Rule Part 24.232(b) specifies that "Mobile/portable stations are limited to 2 watts EIRP. Peak power”
and Rule Part 24.232(c) specifies that "Peak transmit power must be measured over any interval of
continuous transmission using instrumentation calibrated in terms of an rms-equivalent voltage”.


          Limit (EIRP)                               ≤ 2 W (33 dBm)

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 1.19 dB



Test Results:Pass

                                                      Rt        Rs        Ps        Gs       E.I.R.P.
         Mode            Channel   Polarization
                                                    (dBm)     (dBm)     (dBm)      (dBi)     (dBm)
                           25         Vertical      -36.81    -53.71       0        1.92      18.82
                           600        Vertical      -37.71    -53.91       0        1.94      18.14
                          1175        Vertical      -39.31    -54.55       0        1.92      17.16
    CDMA PCS
                           25        Horizontal     -33.35    -53.19       0        1.92      21.76
                           600       Horizontal     -33.00    -53.42       0        1.94      22.36
                          1175       Horizontal     -34.70    -53.64       0        1.92      20.86
Note: 1. EIRP= E.R.P+2.15


                        TA Technology (Shanghai) Co., Ltd.
                                   Test Report
Report No.: RXA1502-0023RF02R2                                                      Page 12of 33



2.4. Occupied Bandwidth

Ambient condition

             Temperature           Relative humidity                Pressure

             23°C ~25°C               45%~50%                       101.5kPa

Method of Measurement

The EUT was connected to Spectrum Analyzer and Base Station Simulator via power Splitter. The
occupied bandwidth is measured using spectrum analyzer. RBW is set to 30kHz, VBW is set to
300kHz for CDMA PCS. 99% power and -26dBc occupied bandwidths are recorded. Spectrum
analyzer plots are included on the following pages.

Test Setup




Limits

No specific occupied bandwidth requirements in part 2.1049.

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 624Hz.


                    TA Technology (Shanghai) Co., Ltd.
                               Test Report
Report No.: RXA1502-0023RF02R2                                         Page 13of 33



Test Result

                                                     99% Power         -26dBc
   CDMA PCS          Channel     Frequency (MHz)
                                                   Bandwidth (MHz) Bandwidth(MHz)
                       25            1851.25           1.2636          1.437
     +F-SCH            600           1880.0            1.2664          1.427
                      1175           1908.75           1.2667          1.428




                     CDMA PCS +F-SCH CH25 Occupied Bandwidth


                    TA Technology (Shanghai) Co., Ltd.
                               Test Report
Report No.: RXA1502-0023RF02R2                                  Page 14of 33




                     CDMA PCS +F-SCH CH600 Occupied Bandwidth




                    CDMA PCS +F-SCH CH1175 Occupied Bandwidth


                         TA Technology (Shanghai) Co., Ltd.
                                    Test Report
Report No.: RXA1502-0023RF02R2                                                          Page 15of 33



2.5. Band Edge Compliance

Ambient condition

             Temperature            Relative humidity                  Pressure

             23°C ~25°C                45%~50%                         101.5kPa



Method of Measurement

The EUT was connected to Spectrum Analyzer and Base Station Simulator via power Splitter. The
band edge of the lowest and highest channels were measured. The Average detector is used and
RBW is set to 15kHz, VBW is set to 30kHz for CDMA PCS. Spectrum analyzer plots are included on
the following pages.

Test Setup




Limits

Rule Part 24.238(a) specifies that “on any frequency outside a licensee's frequency block, the power
of any emission shall be attenuated below the transmitter power (P) by at least 43 + 10 log10 (P) dB.”


                           Limit                                   -13 dBm




Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96, U=0.684dB.


                    TA Technology (Shanghai) Co., Ltd.
                               Test Report
Report No.: RXA1502-0023RF02R2                                    Page 16of 33


Test Result:

                         Carrier
                                     Reference value
      CDMA PCS         frequency                         Limit   Conclusion
                                          (dBm)
                          (MHz)
                         1850.0          -33.061         -13       PASS
       +F-SCH
                         1910.0          -34.983         -13       PASS




                            CDMA PCS +F-SCH 25 Channel


                    TA Technology (Shanghai) Co., Ltd.
                               Test Report
Report No.: RXA1502-0023RF02R2                            Page 17of 33




                           CDMA PCS +F-SCH 1175 Channel


                         TA Technology (Shanghai) Co., Ltd.
                                    Test Report
Report No.: RXA1502-0023RF02R2                                                            Page 18of 33



2.6. Peak-to-Average Power Ratio (PAPR)

Ambient condition

                      Temperature                                   Relative humidity

                       21°C ~25°C                                      40%~60%

Methods of Measurement

The measurement procedures in KDB971168 are used.
The inherent randomness of the power peaks in a noise-like signal makes it difficult to quantify the
peak power using traditional measurement techniques for determining the peak power of an analog
signal. The peak power of a digitally-modulated signal is predictable only on a statistical basis. Thus,
for these types of signals, a statistical measurement of the peak power is necessary.
Power Complementary Cumulative Distribution Function (CCDF) curves provide a means for
characterizing the power peaks of a digitally modulated signal on a statistical basis. A CCDF curve
depicts the probability of the peak signal amplitude exceeding the average power level. Most
contemporary measurement instrumentation include the capability to produce CCDF curves for an
input signal provided that the instrument’s resolution bandwidth can be set wide enough to
accommodate the entire input signal bandwidth.
Step 1. The EUT was connected to Spectrum Analyzer and Base Station via power divider.
Step 2. Set the CCDF option in Spectrum analyzer.
Step 3. Record the maximum PAPR level associated with a probability of 0.1%.


Test Setup




Limits

No specific Peak-to-Average Ratio requirements in KDB 971168.

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the

normal distribution is with the coverage factor k = 2, U= 0.4 dB.


                        TA Technology (Shanghai) Co., Ltd.
                                   Test Report
Report No.: RXA1502-0023RF02R2                                           Page 19of 33

Test Result:




               Mode              Channel   Frequency (MHz)   Test Result(dB)

                                   25          1851.25            3.67
               +F-SCH              600          1880.0            3.87
                                  1175         1908.75            3.91




                            CDMA PCS +F-SCH CH25 Channel


                    TA Technology (Shanghai) Co., Ltd.
                               Test Report
Report No.: RXA1502-0023RF02R2                            Page 20of 33




                          CDMA PCS +F-SCH CH600 Channel




                         CDMA PCS +F-SCH CH1175 Channel


                        TA Technology (Shanghai) Co., Ltd.
                                   Test Report
Report No.: RXA1502-0023RF02R2                                                      Page 21of 33



2.7. Frequency Stability

Ambient condition

             Temperature           Relative humidity                Pressure

             23°C ~25°C               45%~50%                       101.5kPa



Method of Measurement

1. Frequency Stability (Temperature Variation)
   The temperature inside the climate chamber is varied from -40°C to +80°C in 10°C step size,
   (1) With all power removed, the temperature was decreased to -40°C and permitted to stabilize
   for three hours.
   (2) Measure the carrier frequency with the test equipment in a “call mode”. These measurements
   should be made within 1 minute of powering up the mobile station, to prevent significant self
   warming.
   (3) Repeat the above measurements at 10°C increments from -40°C to +80°C. Allow at least 1.5
   hours at each temperature, un-powered, before making measurements.
2. Frequency Stability (Voltage Variation)
   The frequency stability shall be measured with variation of primary supply voltage as follows:
   (1) Vary primary supply voltage from 85 to 115 percent of the nominal value for other than hand
   carried battery equipment.
   (2) For hand carried, battery powered equipment, reduce primary supply voltage to the
   battery-operating end point which shall be specified by the manufacturer.
   This transceiver is specified to operate with an input voltage of between 6 V and 40 V, with a
   nominal voltage of 12V.

Test setup


                         TA Technology (Shanghai) Co., Ltd.
                                    Test Report
Report No.: RXA1502-0023RF02R2                                                        Page 22of 33



Limits

No specific frequency stability requirements in part 24.235

Measurement Uncertainty

The assessed measurement uncertainty to ensure 99.75% confidence level for the normal
distribution is with the coverage factor k = 3, U= 0.01ppm.

Test Result

                                             Test Results (ppm) / 12 V Power supply
                   Temperature
                                                          Channel 600
                      (°C)
                                                              +F-SCH
                        -40                               -0.005521277
                        -30                               -0.005824468
                        -20                               -0.006159574
                        -10                               -0.006037234
                         0                                -0.00587234
                        10                                -0.006154255
                        20                                -0.006085106
                        30                                -0.005930851
                        40                                -0.006446809
                        50                                -0.006414894
                        60                                -0.006042553
                        70                                -0.006691489
                        80                                -0.006611702


                                                   Test Results(ppm) / 20°C
                     Voltage
                                                         Channel 600
                       (V)
                                                              +F-SCH
                        6                                -0.006670213
                       12                                -0.006085106
                       40                                -0.008765957


                         TA Technology (Shanghai) Co., Ltd.
                                    Test Report
Report No.: RXA1502-0023RF02R2                                                          Page 23of 33


2.8. Spurious Emissions at Antenna Terminals

Ambient condition

             Temperature            Relative humidity                  Pressure

             23°C ~25°C                45%~50%                         101.5kPa



Method of Measurement

The EUT was connected to Spectrum Analyzer and Base Station Simulator via power Splitter. The
measurement is carried out using a spectrum analyzer. The spectrum analyzer scans from 30MHz to
the 10th harmonic of the carrier. For CDMA PCS, RBW and VBW are set to 100 kHz, Sweep is set to
ATUO.
Of those disturbances below (limit – 20 dB), the mark is not required for the EUT.

Test setup




Limits


Rule Part 24.238(a) specifies that “on any frequency outside a licensee's frequency block, the power
of any emission shall be attenuated below the transmitter power (P) by at least 43 + 10 log10 (P) dB.”
                            Limit                                  -13 dBm



Measurement Uncertainty

The assessed measurement uncertainty to ensure 99.75% confidence level for the normal
distribution is with the coverage factor k = 1.96.
                       Frequency                                  Uncertainty

                      100kHz-2GHz                                   0.684 dB

                      2GHz-18GHz                                    1.407 dB


                                         TA Technology (Shanghai) Co., Ltd.
                                                    Test Report
Report No.: RXA1502-0023RF02R2                                                                                                              Page 24of 33


Test Result

CDMA PCS CH25

                              0

                              -5

                             -10
                                                                                                                                      FCC CSE
                             -15

                             -20
                             -25

                             -30
              Level in dBm




                             -35

                             -40

                             -45

                             -50

                             -55

                             -60

                             -65

                             -70

                             -75

                             -80
                               30M   50 60    80 100M      200    300 400 500       800 1G             2G    3G    4G 5G 6   8 10G        18G
                                                                             Frequency in Hz



                                                Note: The signal beyond the limit is carrier.
                                                    CDMA PCS CH25 30MHz~18GHz




                               0


                              -10                                                                                                     FCC CSE


                              -20


                              -30


                              -40
              Level in dBm




                              -50


                              -60


                              -70


                              -80


                              -90


                             -100
                                18     18.2        18.4    18.6       18.8          19          19.2        19.4      19.6     19.8        20
                                                                             Frequency in GHz



                                                        CDMA PCS CH25 18GHz ~20GHz


                                     TA Technology (Shanghai) Co., Ltd.
                                                Test Report
Report No.: RXA1502-0023RF02R2                                                                                                          Page 25of 33

CDMA PCS CH600

                          0

                          -5

                         -10

                         -15

                         -20
                         -25

                         -30
          Level in dBm




                         -35

                         -40

                         -45

                         -50

                         -55

                         -60

                         -65

                         -70

                         -75

                         -80
                           30M   50 60    80 100M      200     300 400 500       800 1G             2G    3G    4G 5G 6   8 10G       18G
                                                                          Frequency in Hz



                                            Note: The signal beyond the limit is carrier.
                                               CDMA PCS CH600 30MHz~18GHz




                           0


                          -10                                                                                                      FCC CSE


                          -20


                          -30


                          -40
          Level in dBm




                          -50


                          -60


                          -70


                          -80


                          -90


                         -100
                            18     18.2        18.4     18.6       18.8          19          19.2        19.4      19.6     19.8        20
                                                                          Frequency in GHz



                                                    CDMA PCS CH600 18GHz ~20GHz


                                     TA Technology (Shanghai) Co., Ltd.
                                                Test Report
Report No.: RXA1502-0023RF02R2                                                                                                        Page 26of 33

CDMA PCS CH1175

                          0

                          -5

                         -10

                         -15

                         -20
                         -25

                         -30
          Level in dBm




                         -35

                         -40

                         -45

                         -50

                         -55

                         -60

                         -65

                         -70

                         -75

                         -80
                           30M   50 60    80 100M     200    300 400 500       800 1G             2G    3G    4G 5G 6   8 10G       18G
                                                                        Frequency in Hz



                                            Note: The signal beyond the limit is carrier.
                                              CDMA PCS CH1175 30MHz~18GHz




                           0


                          -10                                                                                                    FCC CSE


                          -20


                          -30


                          -40
          Level in dBm




                          -50


                          -60


                          -70


                          -80


                          -90


                         -100
                            18     18.2        18.4   18.6       18.8          19          19.2        19.4      19.6     19.8        20
                                                                        Frequency in GHz



                                                CDMA PCS CH1175 18GHz ~20GHz


                         TA Technology (Shanghai) Co., Ltd.
                                    Test Report
Report No.: RXA1502-0023RF02R2                                                         Page 27of 33



2.8 Radiates Spurious Emission

Ambient condition

             Temperature            Relative humidity                 Pressure

             23°C ~25°C                45%~50%                        101.5kPa

Method of Measurement

The measurements procedures in TIA -603C are used.
The spectrum was scanned from 30 MHz to the 10th harmonic of the highest frequency generated
within the equipment.
The procedure of Radiates Spurious Emission is as follows:
Step 1:
The measurement is carried out in the semi-anechoic chamber. EUT was placed on a 1.5 meters
high non-conductive table at a 3 meters test distance from the test receive antenna. A receiving
antenna was placed on the antenna mast 3 meters from the EUT. A radio link shall be established
between EUT and Tester. The output power of the cell signal of the tester will be decreased until the
output power of the EUT reach a maximum value. A peak detector is used while RBW and VBW are
both set to 3MHz. During the measurement, the highest emission was recorded from analyzer power
level (LVL) from the 360 degrees rotation of the turntable and the test antenna moved up and down
over a range from 1 to 4 meters in both horizontally and vertically polarized orientations. The test
setup refers to figure below.




Step 2:
  A dipole antenna shall be substituted in place of the EUT. The antenna will be driven by a signal
generator with a adjustable S.G. applied through a Tx cable. Adjust the level of the signal generator
output until the value of the receiver reach the previously recorded analyzer power level (LVL).Then
The E.R.P. /E.I.R.P. of the EUT can be calculated through the level of the signal generator, Tx cable
 loss and the gain of the substitution antenna. The test setup refers to figure below.


                         TA Technology (Shanghai) Co., Ltd.
                                    Test Report
Report No.: RXA1502-0023RF02R2                                                          Page 28of 33




E.R.P(peak power)=S.G. - Tx Cable loss + Substitution antenna gain – 2.15.
EIRP= E.R.P+2.15



The field strength of spurious emission was measured in the following position: EUT stand-up
position (Z axis), lie-down position (X, Y axis). The worst emission was found in stand-up position (Z
axis) and the antenna is vertical.

Of those disturbances below (limit – 20 dB), the mark is not required for the EUT.

Limits

Rule Part 24.238(a) specifies that “on any frequency outside a licensee's frequency block, the power
of any emission shall be attenuated below the transmitter power (P) by at least 43 + 10 log10 (P) dB.”


                           Limit                                   -13 dBm



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution
is with the coverage factor k = 1.96, U= 3.55 dB.


                                  TA Technology (Shanghai) Co., Ltd.
                                             Test Report
        Report No.: RXA1502-0023RF02R2                                                             Page 29of 33


        Test Result

        CDMA Cellular CH1013

               TX ch.1013                Cable                                  ERP
                                 SG                 Gain       Antenna                     Limit    Margin      Azimuth
Harmonic       Frequency                 Loss                                  Level
                               (dBm)                (dBi)     Polarization                (dBm)      (dB)        (deg)
                 (MHz)                   (dB)                                  (dBm)
   2             1649.6        -45.21       2       10.15        Vertical      -46.45       -13      33.45           270

   3             2474.1        -66.74     2.51      11.35        Vertical      -60.05       -13      47.05           0

   4             3478.5        -64.45      4.2      10.85        Vertical      -46.26       -13      33.26           225

   5             4123.5        -62.89      5.2      11.35        Vertical      -58.89       -13      45.89           90

   6             4947.4        -63.43      5.5      11.95        Vertical      -50.39       -13      37.39           225

   7             5774.6        -61.76      5.7      13.55        Vertical      -42.59       -13      29.59           315

   8             6594.8        -61.10      6.3      13.75        Vertical      -46.93       -13      33.93           270

   9             7419.4        -61.08      6.8      13.85        Vertical      -48.08       -13      35.08           180

   10            8249.6        -61.86      6.9      14.25        Vertical      -39.76       -13      26.76           270
          Note: 1.The other Spurious RF Radiated emissions level is no more than noise floor.
        2.We tested the vertical and horizontal polarization in the preliminary test and the vertical polarization
        are selected as the worst condition,

        CDMA Cellular CH384
               TX ch.384                 Cable                                  ERP
                                 SG                 Gain       Antenna                     Limit    Margin      Azimuth
Harmonic       Frequency                 Loss                                  Level
                               (dBm)                (dBi)     Polarization                (dBm)      (dB)        (deg)
                 (MHz)                   (dB)                                  (dBm)
   2             1672.3        -50.43       2       10.75        Vertical      -39.66       -13      26.66           180

   3             2509.56       -62.78     2.51      11.05        Vertical      -56.39       -13      43.39            0

   4             3526.2        -64.61      4.2      11.15        Vertical      -46.24       -13      33.24           180

   5             4182.6        -62.67      5.2      11.15        Vertical      -58.87       -13      45.87           90

   6             5019.12       -61.23      5.5      11.95        Vertical      -56.93       -13      43.93            0

   7             5856.8        -62.70      5.7      13.55        Vertical      -42.48       -13      29.48           315

   8             6694.1        -61.77      6.3      13.75        Vertical      -48.78       -13      35.78           270

   9             7528.68       -60.26      6.8      13.85        Vertical      -55.36       -13      42.36            0

   10            8365.9        -61.88      6.9      14.25        Vertical      -49.23       -13      36.23           270
          Note: 1.The other Spurious RF Radiated emissions level is no more than noise floor.
        2.We tested the vertical and horizontal polarization in the preliminary test and the vertical polarization
        are selected as the worst condition,


                                  TA Technology (Shanghai) Co., Ltd.
                                             Test Report
        Report No.: RXA1502-0023RF02R2                                                             Page 30of 33

        CDMA Cellular CH777


              TX ch.777                  Cable                                 ERP
                                SG                 Gain       Antenna                     Limit     Margin     Azimuth
Harmonic      Frequency                  Loss                                 Level
                              (dBm)                (dBi)     Polarization                (dBm)       (dB)       (deg)
                (MHz)                    (dB)                                 (dBm)
   2             1697.1       -55.04       2       10.15       Vertical       -40.51       -13       27.51           270
   3            2544.93        -56.6      2.51     11.05       Vertical       -50.21       -13       37.21            0
   4             3573.0       -64.16      4.2      11.15       Vertical       -45.37       -13       32.37            0
   5            4241.55       -61.50      5.2      11.15       Vertical       -57.70       -13       44.70           180
   6            5089.86       -62.89      5.5      11.95       Vertical       -58.59       -13       45.59           90
   7             5936.3       -63.04      5.7      13.55       Vertical       -45.31       -13       32.31            0
   8            6786.48       -60.84      6.3      13.75       Vertical       -55.54       -13       42.54           270
   9             7632.8       -60.52      6.8      13.85       Vertical       -47.67       -13       34.67           45
   10            8483.3       -62.22      6.9      14.25       Vertical       -49.65       -13       36.65           225
          Note: 1.The other Spurious RF Radiated emissions level is no more than noise floor.
        2.We tested the vertical and horizontal polarization in the preliminary test and the vertical polarization
        are selected as the worst condition,


                           TA Technology (Shanghai) Co., Ltd.
                                      Test Report
     Report No.: RXA1502-0023RF02R2                                                 Page 31of 33



     3. Main Test Instruments

                                                                  Calibration   Expiration    Valid
No.        Name           Type     Manufacturer   Serial Number
                                                                    Date          Time       Period
        Base Station
01                       CMU200        R&S           118133       2014-05-26    2015-05-25   1 year
         Simulator
                         SHX-GF2
02      Power Splitter              Hua Xiang      10120101          NA            NA          NA
                          -2-13
          Spectrum
03                       E4445A       Agilent     MY46181146      2014-05-26    2015-05-25   1 year
          Analyzer
       Universal Radio
04     Communication     E5515C       Agilent     MY48367192      2014-05-26    2015-05-25   1 year
           Tester
05     Signal Analyzer    FSV30        R&S           100815       2014-05-26    2015-05-25   1 year
           Signal         SMB
06                                     R&S           102594       2014-05-26    2015-05-25   1 year
          generator       100A
          EMI Test
07                        ESCI         R&S           100948       2014-05-26    2015-05-25   1 year
          Receiver
                          VUBL     SCHWARZBE
08     Trilog Antenna                               9163-201      2012-06-19    2015-06-18   3 years
                          9163        CK
                          VUBL     SCHWARZBE
09     Trilog Antenna                               9163-391      2012-06-19    2015-06-18   3 years
                          9163        CK
10      Horn Antenna      HF907        R&S           100126       2012-07-01    2015-06-30   3 years

11      Horn Antenna      HF907        R&S           100125       2012-07-01    2015-06-30   3 years
          Climatic
12                       PT-30B       Re Ce        20101891       2014-09-01    2017-08-31   3 years
          Chamber
13      Horn Antenna     3160-09   ETS-Lindgren    00102643       2012-05-17    2015-05-16   3 years

14      Horn Antenna     3160-09   ETS-Lindgren    00102644       2012-05-17    2015-05-16   3 years
                          SMA                                                                 Two
15        RF Cable                    Agilent         0001        2015-02-09    2015-04-08
                          15cm                                                               months



                                      *****END OF REPORT *****


                    TA Technology (Shanghai) Co., Ltd.
                               Test Report
Report No.: RXA1502-0023RF02R2                             Page 32of 33



ANNEX A: EUT Appearance and Test Setup

 A.1    EUT Appearance




                             Picture 1 EUT and Auxiliary


                    TA Technology (Shanghai) Co., Ltd.
                               Test Report
Report No.: RXA1502-0023RF02R2                                         Page 33of 33



A.2   Test Setup




                   Picture 2: Radiated Spurious Emissions Test setup



Document Created: 2015-03-20 18:12:44
Document Modified: 2015-03-20 18:12:44

© 2024 FCC.report