Appendix_B

FCC ID: YHLBLUC5PLUS

RF Exposure Info

Download: PDF
FCCID_4432801

Test Laboratory: UnionTrust                                                Date: 2019/815


PO1_GSMS850_GPRS 11_Left Cheek_128
DUT: EUT

Communication System: GPRS 850—3solt; Frequency: 824.2 MHz;Duty Cycle: 1:2.67
Medium: H835 Medium parameters used (interpolated): £=824.2 MHz; 0 =0.912 mho/m; 8.=42.7;
p = 1000 kg/m}

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(6.12, 6.12, 6.12); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 $n662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Measurement grid: dx=1 5mm, dy=1 5mm

Maximum value of SAR (interpolated)= 0.084 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=5mm
Reference Value=4.17 V/m; Power Drift=0.02 dB
Peak SAR (extrapolated) = 0.120 W/kg
SAR(1 g) = 0.089 mW/g; SAR(10 g) = 0.060 mW/g

Maximum value of SAR (measured) =0.108 mW/g

   mWig
    0.084

    0.067

    0.050

    0.034

    0.017

    0.000


Test Laboratory: UnionTrust                                                   Date: 2019/8/15


PO2_GSM1900_GPRS 11_Right Cheek_512
DUT: EUT

Communication System: GPRS1900—3slots; Frequency: 1850.2 MHz;Duty Cycle: 1:2.67
Medium: H1900 Medium parameters used (interpolated): £= 1850.2 MHz; 0 = 1.35 mho/m; 8. <41.6;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(5.06, 5.06, 5.06); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Measurement grid: dx=1 5mm, dy=1 Smm

Maximum value of SAR (interpolated) = 0.094 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 3.98 V/m; Power Drift=0.01 dB
Peak SAR (extrapolated)= 0.120 W/kg
SAR(1 g) = 0.075 mW/g; SAR(10 g) = 0.047 mW/g
Maximum value of SAR (measured) = 0.088 mW/g

   mWiq
    0.094

    0.075

    0.057

    0.038

    0.020

    0.001


Test Laboratory: UnionTrust                                                Date: 2019/8/15


PO3_WCDMA II_RMC12.2K_Right Cheek_9538
DUT: EUT

Communication System: WCDMA BandII; Frequency: 1907.6 MHz;Duty Cycle: 1:1
Medium: H1900 Medium parameters used: £=1908 MHz; 0 = 1.42 mho/m; 8.= 41.3; p=1000
kg/m>

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(5.06, 5.06, 5.06); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Measurement grid: dx=1 5mm, dy=1 Smm
Maximum value of SAR (interpolated) = 0.208 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=7.77 V/m; Power Drift=—0.054 dB
Peak SAR (extrapolated)= 0.284 W/kg
SAR(1 g) = 0.167 mW/g; SAR(10 g) = 0.094 mW/g
Maximum value of SAR (measured) =0.210 mW/g

   mWiq
    0.208

    0.166

    0.125

    0.083

    0.042

    0.000


Test Laboratory: UnionTrust                                                  Date: 2019/8/15


PO4_WCDMA V_RMC12.2K_Left Cheek_4132
DUT: EUT

Communication System: WCDMA Band V; Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: H835 Medium parameters used (interpolated): £=826.4 MHz; 0 =0.914 mho/m; 8. = 42.7;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(6.12, 6.12, 6.12); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Measurement grid: dx=1 5mm, dy=1 Smm

Maximum value of SAR (interpolated) = 0.041 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 4.69 V/m; Power Drift=0.080 dB
Peak SAR (extrapolated)= 0.040 W/kg
SAR(1 g) = 0.033 mW/g; SAR(10 g) = 0.024 mW/g
Maximum value of SAR (measured) =0.036 mW/g

   mWiq
    0.0471

    0.033

    0.025

    0.016

    0.008

    0.000


Test Laboratory: UnionTrust                                                Date: 2019/8/16


PO5_802.11b_Right Cheek_1
DUT: EUT

Communication System: Wlan 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1
Medium: H2450 Medium parameters used: £=2412 MHz; 0 = 1.72 mho/m; 8.= 40.3; p = 1000
kg/m>

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(4.57, 4.57, 4.57); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Measurement grid: dx=1 2mm, dy=12mm
Maximum value of SAR (interpolated) = 0.194 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=7.46 V/m; Power Drift=0.006 dB
Peak SAR (extrapolated)= 0.358 W/kg
SAR(1 g) = 0.168 mW/g; SAR(10 g) = 0.088 mW/g
Maximum value of SAR (measured) = 0.226 mW/g

   mWig
    0.194

    0.155

    0.116

    0.078

    0.039

    0.000


Test Laboratory: UnionTrust                                                   Date: 2019/8/15


PO6_GSM850 _GPRS11_Rear Face_10mm_128
DUT: EUT

Communication System: GPRS 850—3solt; Frequency: 824.2 MHz;Duty Cycle: 1:2.67
Medium: B835 Medium parameters used (interpolated): {= 824.2 MHz; 0 =0.981 mho/m; 8. = 55.9;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(6.18, 6.18, 6.18); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (71x61x1): Measurement grid: dx=1 5mm, dy=1 Smm

Maximum value of SAR (interpolated) = 0.199 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=13.6 V/m; Power Drift=—0.101 dB
Peak SAR (extrapolated)= 0.232 W/kg
SAR(1 g) = 0.169 mW/g; SAR(10 g) = 0.118 mW/g
Maximum value of SAR (measured) = 0.188 mW/g

   mWiq
    p.199

    o162
    0126                                         \
    0.089

    0.053

    0.016


Test Laboratory: UnionTrust                                                   Date: 2019/8/15


PO7_GSM1900 _GPRS11_Rear Face_10mm_512
DUT: EUT

Communication System: GPRS1900—3slots; Frequency: 1850.2 MHz;Duty Cycle: 1:2.67
Medium: B1900 Medium parameters used (interpolated): {= 1850.2 MHz; 0 = 1.49 mho/m; 8. =52.7;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(4.79, 4.79, 4.79); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (71x61x1): Measurement grid: dx=1 5mm, dy=1 Smm

Maximum value of SAR (interpolated) = 0.317 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 4.63 V/m; Power Drift=0.068 dB
Peak SAR (extrapolated)= 0.417 W/kg
SAR(1 g) = 0.257 mW/g; SAR(10 g) = 0.143 mW/g
Maximum value of SAR (measured) =0.313 mW/g

   mWiq
    0.317

    0.255

    0.193

    0.131

    0.069

    0.007


Test Laboratory: UnionTrust                                                Date: 2019/8/15


PO8_WCDMA II _RMC12.2K_Rear Face_10mm_9538
DUT: EUT

Communication System: WCDMA Band IV; Frequency: 1732.6 MHz;Duty Cycle: 1:1
Medium: B1750 Medium parameters used: £= 1733 MHz; 0 = 1.46 mho/m; &.= 52.4; p= 1000
kg/m>

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(4.95, 4.95, 4.95); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x61x1): Measurement grid: dx=1 5mm, dy=1 Smm
Maximum value of SAR (interpolated) = 0.719 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 12.2 V/m; Power Drift=—0.07 dB
Peak SAR (extrapolated)= 0.948 W/kg
SAR(1 g) = 0.590 mW/g; SAR(10 g) = 0.328 mW/g
Maximum value of SAR (measured) = 0.700 mW/g

   mWilg
    0.719

    0.577

    0.435

    0.292

    0.150

    0.008


Test Laboratory: UnionTrust                                                    Date: 2019/8/15


PO9_WCDMA V _RMC12.2K_Right Side_10mm_4132
DUT: EUT

Communication System: WCDMA Band V; Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: B835 Medium parameters used (interpolated): {= 826.4 MHz; 0 = 0.983 mho/m; 8. = 55.9;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(6.18, 6.18, 6.18); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (81x61x1): Measurement grid: dx=1 5mm, dy=1 5mm

Maximum value of SAR (interpolated) = 0.051 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 6.08 V/m; Power Drift=—0.119 dB
Peak SAR (extrapolated)= 0.054 W/kg
SAR(1 g) = 0.042 mW/g; SAR(10 g) = 0.029 mW/g
Maximum value of SAR (measured) = 0.048 mW/g

   mWiq
    0.051

    0.041

    0.031

    0.021

    0.011

    0.001


Test Laboratory: UnionTrust                                                Date: 2019/8/16


P10_802.11b_Rear Face_l10mm_1

DUT: EUT

Communication System: Wlan 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1
Medium: B2450 Medium parameters used: £=2412 MHz; 0 = 1.96 mho/m; &.= 53.1; p=1000
kg/m>

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(4.47, 4.47, 4.47); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (71x61x1): Measurement grid: dx=1 2mm, dy=12mm
Maximum value of SAR (interpolated)= 0.151 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 3.29 V/m; Power Drift=—0.165 dB
Peak SAR (extrapolated)= 0.199 W/kg
SAR(1 g) = 0.123 mW/g; SAR(10 g) = 0.074 mW/g
Maximum value of SAR (measured) = 0.145 mW/g

   mWilq
    0.145

    0.116

    0.088

    0.059

    0.031

    0.002


Test Laboratory: UnionTrust                                                    Date: 2019/8/15


P11_WCDMA V _RMC12.2K_Front Face_10mm_4132
DUT: EUT

Communication System: WCDMA Band V; Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: B835 Medium parameters used (interpolated): {= 826.4 MHz; 0 = 0.983 mho/m; 8. = 55.9;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(6.18, 6.18, 6.18); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (81x61x1): Measurement grid: dx=1 5mm, dy=1 5mm

Maximum value of SAR (interpolated) = 0.043 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 6.52 V/m; Power Drift=—0.106 dB
Peak SAR (extrapolated)= 0.044 W/kg
SAR(1 g) = 0.038 mW/g; SAR(10 g) = 0.029 mW/g
Maximum value of SAR (measured) =0.041 mW/g

   mWiq
    0.043

    0.035

    0.028
                                                   &
    0.020
                                                   y
    0.013

    0.005