RF Exposure

FCC ID: Y3J-U9921

RF Exposure Info

Download: PDF
FCCID_1420821

Test Number: 123-11                                                                   Issue Date: 2/11/2011

6. Measurement Data (continued)
  6.11. Public Exposure to Radio Frequency Energy Levels (1.1307 (b)(1))
        RSS-GEN 5.5, RSS 102
     6.11.1. MPE Power Density Table.

                 MPE                             DUT                Power Density
                             DUT Output                                                      Limit
 Channel       Distance                         Antenna                                                Result
                             Power (dBm)                                                   (mW/cm2)
                 (cm)                          Gain (dBi)
                                                                (mW/cm2)        (W/m2)
                  (1)             (2)              (3)                    (4)                (5)
   TX4            20             18.00            3.00            0.025          0.250        1       Compliant
   TX2            20             17.91            3.00            0.025          0.245        1       Compliant
   TX0            20             17.83            3.00            0.024          0.241        1       Compliant


                                                      OP + AG
                                           PD =
                                                     (4 x π x d²)
                                            PD = Power Density
                                            OP = DUT Output Power (dBm)
                                            AG = Antenna Gain (dBi)
                                             D = MPE Distance

         1.   Reference CFR 2.1093(b): For purposes of this section, a portable device is defined as a
              transmitting device designed to be used so that the radiating structure(s) of the device is/are
              within 20 centimeters of the body of the user.
         2.   Section 6.3 of this test report.
         3.   Data supplied by the client.
         4.   Power density is calculated from conducted power output measurement and antenna gain.
         5.   Reference CFR 1.1310, Table 1: Limits for Maximum Permissible Exposure (MPE), Section
              (B): Limits for General Population/Uncontrolled Exposure.




                                                  Page 45 of 50
                        Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
                                           (603) 887 3903 Fax 887 6445
                                              http://www.cw-inc.com