Test Report

FCC ID: XR3-MAX

Test Report

Download: PDF
FCCID_3092738

                                    MRT Technology (Suzhou) Co., Ltd            Report No.: 1606RSU02104
                                    Phone: +86-512-66308358                     Report Version:        V01
                                    Fax:   +86-512-66308368                     Issue Date:     08-09-2016
                                    Web:    www.mrt-cert.com




                         MEASUREMENT REPORT
                                         FCC Part 15B


FCC ID:                         XR3-MAX

APPLICANT:                      ONYX INTERNATIONAL INC.



Application Type:              Certification
 Product:                      E-reader
 Model No.:                    Max, Max Carta, Max Carta Plus, Max Pro
 FCC Rule Part(s):             FCC Part 15 Subpart B: 2016
 Test Procedure(s):            ANSI C63.4: 2014
 Test Date:                    June 17 ~ July 13, 2016




 Reviewed By               :
                                  ( Robin Wu )
 Approved By               :
                                 ( Marlin Chen )




The test results relate only to the samples tested.
This equipment has been shown to be capable of compliance with the applicable technical standards as
indicated in the measurement report and was tested in accordance with the measurement procedures specified
in ANSI C63.4-2014. Test results reported herein relate only to the item(s) tested.
The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou)
Co., Ltd.
 FCC ID: XR3-MAX                                                                          Page Number: 1 of 29


                                                        Report No.: 1606RSU02104


                            Revision History

   Report No.     Version            Description               Issue Date

 1606RSU02104     Rev. 01             Initial report           08-05-2016

 1606RSU02104     Rev. 02         Added serial number          08-09-2016




FCC ID: XR3-MAX                                              Page Number: 2 of 29


                                                                                                             Report No.: 1606RSU02104


                                                           CONTENTS
Description                                                                                                                               Page
§2.1033 General Information ......................................................................................................... 4

1.     INTRODUCTION ..................................................................................................................... 5

      1.1.       Scope ........................................................................................................................... 5
      1.2.       MRT Test Location ........................................................................................................ 5

2.     PRODUCT INFORMATION ..................................................................................................... 6

      2.1.       Product Specification Subjective to this Report ............................................................. 6
      2.2.       Test Mode .................................................................................................................... 6
      2.3.       Test Configuration ........................................................................................................ 7
      2.4.       Test System Details ...................................................................................................... 9
      2.5.       Test Software ............................................................................................................... 9
      2.6.       EMI Suppression Device(s)/Modifications ..................................................................... 9

3.     DESCRIPTION OF TEST ...................................................................................................... 10

      3.1.       Evaluation Procedure ................................................................................................. 10
      3.2.       AC Line Conducted Emissions ................................................................................... 10
      3.3.       Radiated Emissions ..................................................................................................... 11

4.     TEST EQUIPMENT CALIBRATION DATE ............................................................................ 12

5.     MEASUREMENT UNCERTAINTY ......................................................................................... 13

6.     TEST RESULT ...................................................................................................................... 14

      6.1.       Summary .................................................................................................................... 14
      6.2.       Conducted Emission Measurement ............................................................................ 15
      6.2.1.        Test Limit ................................................................................................................ 15
      6.2.2.        Test Setup............................................................................................................... 15
      6.2.3.        Test Result of Conducted Emissions ....................................................................... 16
      6.3.       Radiated Emission Measurement ............................................................................... 20
      6.3.1.        Test Limit ................................................................................................................ 20
      6.3.2.        Test Setup............................................................................................................... 20
      6.3.3.        Test Result of Radiated Emissions .......................................................................... 22




FCC ID: XR3-MAX                                                                                                       Page Number: 3 of 29


                                                                        Report No.: 1606RSU02104


§2.1033 General Information
Applicant:                    ONYX INTERNATIONAL INC.
Applicant Address:            Room 102, 3rd Floor, No. 38 HongLou Road, LiWan District,
                              GuangZhou, China
Manufacturer:                 ONYX INTERNATIONAL INC.
Manufacturer Address:         Room 102, 3rd Floor, No. 38 HongLou Road, LiWan District,
                              GuangZhou, China
Test Site:                    MRT Technology (Suzhou) Co., Ltd
Test Site Address:            D8 Building, Youxin Industrial Park, No.2 Tian’edang Rd., Wuzhong
                              Economic Development Zone, Suzhou, China
MRT FCC Registration No.:     809388
FCC ID:                       XR3-MAX
Model No.:                    Max, Max Carta, Max Carta Plus, Max Pro
Test Device Serial No.:       N/A             Production      Pre-Production      Engineering


Test Facility / Accreditations
Measurements were performed at MRT Laboratory located in Tian’edang Rd., Suzhou, China.
 MRT facility is a FCC registered (MRT Reg. No. 809388) test facility with the site description
  report on file and has met all the requirements specified in Section 2.948 of the FCC Rules.
 MRT facility is an IC registered (MRT Reg. No. 11384A-1) test laboratory with the site
  description on file at Industry Canada.
 MRT facility is a VCCI registered (R-4179, G-814,
  C-4664, T-2206) test laboratory with the site description
  on file at VCCI Council.
 MRT Lab is accredited to ISO 17025 by the American
  Association for Laboratory Accreditation (A2LA) under
  the American Association for Laboratory Accreditation
  Program (A2LA Cert. No. 3628.01) in EMC,
  Telecommunications and Radio testing for FCC,
  Industry Canada, EU and TELEC Rules.




FCC ID: XR3-MAX                                                                Page Number: 4 of 29


                                                                            Report No.: 1606RSU02104



1.    INTRODUCTION
1.1. Scope
Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices
including intentional and/or unintentional radiators for compliance with the technical rules and
regulations of the Federal Communications Commission and the Industry Canada Certification and
Engineering Bureau.



1.2. MRT Test Location
The map below shows the location of the MRT LABORATORY, its proximity to the Taihu Lake.
These measurement tests were conducted at the MRT Technology (Suzhou) Co., Ltd. Facility
located at D8 Building, Youxin Industrial Park, No.2 Tian’edang Rd., Wuzhong Economic
Development Zone, Suzhou, China. The detailed description of the measurement facility was found
to be in compliance with the requirements of § 2.948 according to ANSI C63.4-2009 on September
30, 2013.




FCC ID: XR3-MAX                                                                   Page Number: 5 of 29


                                                                   Report No.: 1606RSU02104



2.    PRODUCT INFORMATION
2.1. Product Specification Subjective to this Report
Product Name             E-reader
Model No.                Max, Max Carta, Max Carta Plus, Max Pro
Wi-Fi Specification      802.11b/g/n-HT20
Bluetooth Version        v3.0 + HS, v4.0
Components
Adapter                  M/N: HKC0055010-2D
                         INPUT: 100-240V ~ 50/60Hz, 0.2A
                         OUTPUT: 5Vdc, 1.0A



2.2. Test Mode
Mode 1: Charging + Reading + Playing Music
Mode 2: USB Copy




FCC ID: XR3-MAX                                                         Page Number: 6 of 29


                                                                         Report No.: 1606RSU02104



2.3. Test Configuration
The EUT was tested per the guidance FCC Part 15 Subpart B: 2016 and ANSI C63.4: 2014 was
used to reference the appropriate EUT setup for radiated spurious emissions testing and AC line
conducted testing.

Connection Diagram (Mode 1)




FCC ID: XR3-MAX                                                               Page Number: 7 of 29


                                                         Report No.: 1606RSU02104


Connection Diagram (Mode 2)




Signal Cable Type             Signal Cable Description
A     USB Cable               Shielded, 0.5m
B     Earphone Cable          Non-Shielded, 1.2m
C     USB Cable               Shielded, 1.8m




FCC ID: XR3-MAX                                               Page Number: 8 of 29


                                                                            Report No.: 1606RSU02104



2.4. Test System Details
The types for all equipments, plus descriptions of all cables used in the tested system (including
inserted cards) are:
Product                 Manufacturer        Model No.       Serial No.         Power Cord
1     Earphone          Taijie              N/A             N/A                N/A
2     Notebook          Lenovo              E430c           MP-4CFX213/10 Non-Shielded, 1.8m
3     USB Mouse         DELL                MS111-T         N/A                N/A



2.5. Test Software
1   Setup the EUT and simulators as shown on above.
2   Turn on the power of all equipment.
    (1), Making EUT working on “Charging + Reading” Mode + Playing Music.
3
    (2), Making EUT working on “USB Copy” Mode.



2.6. EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and/or no modifications were made during testing.




FCC ID: XR3-MAX                                                                  Page Number: 9 of 29


                                                                             Report No.: 1606RSU02104



3.    DESCRIPTION OF TEST
3.1. Evaluation Procedure
The measurement procedures described in the American National Standard for Methods of
Measurement of Radio-Noise Emission from Low-Voltage Electrical Equipment in the Range of 9kHz
to 40GHz (ANSI C63.4-2014) was used in the measurement of the E-reader
Deviation from measurement procedure…………………………….....................................None



3.2. AC Line Conducted Emissions
The line-conducted facility is located inside an 8'x4'x4' shielded enclosure. A 1m x 2m wooden table
80cm high is placed 40cm away from the vertical wall and 80cm away from the sidewall of the
shielded room. Two 10kHz-30MHz, 50Ω/50uH Line-Impedance Stabilization Networks (LISNs) are
bonded to the shielded room floor. Power to the LISNs is filtered by external high-current
high-insertion loss power line filters. These filters attenuate ambient signal noise from entering the
measurement lines. These filters are also bonded to the shielded enclosure.
The EUT is powered from one LISN and the support equipment is powered from the second LISN. If
the EUT is a DC-powered device, power will be derived from the source power supply it normally will
be powered from and this supply line(s) will be connected to the second LISN. All interconnecting
cables more than 1 meter were shortened to a 1 meter length by non-inductive bundling (serpentine
fashion) and draped over the back edge of the test table. All cables were at least 40cm above the
horizontal reference ground-plane. Power cables for support equipment were routed down to the
second LISN while ensuring that that cables were not draped over the second LISN.
Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to
warm up to their normal operating condition. The RF output of the LISN was connected to the
receiver and exploratory measurements were made to determine the frequencies producing the
maximum emission from the EUT. The receiver was scanned from 150 kHz to 30 MHz. The detector
function was set to peak mode for exploratory measurements while the bandwidth of the analyzer
was set to 9 kHz. The EUT, support equipment, and interconnecting cables were arranged and
manipulated to maximize each emission. Each emission was also maximized by varying: power lines,
the mode of operation or resolution, clock or data exchange speed, scrolling H pattern to the EUT
and/or support equipment whichever determined the worst-case emission. Once the worst case
emissions have been identified, the one EUT cable configuration/arrangement and mode of
operation that produced these emissions are used for final measurements on the same test site.
Line conducted emissions test results are shown in Section 6.2.




FCC ID: XR3-MAX                                                                    Page Number: 10 of
29


                                                                              Report No.: 1606RSU02104



3.3. Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final
measurements and exploratory measurements, when necessary. The measurement area is
contained within the semi-anechoic chamber which is shielded from any ambient interference. For
measurements above 1GHz absorbers are arranged on the floor between the turn table and the
antenna mast in such a way so as to maximize the reduction of reflections. For measurements below
1GHz, the absorbers are removed. An MF Model 210SS turntable is used for radiated measurement.
It is a continuously rotatable, remote controlled, metallic turntable and 2 meters (6.56 ft.) in diameter.
The turn table is flush with the raised floor of the chamber in order to maintain its function as a
ground plane. An 80cm high PVC support structure is placed on top of the turntable.
For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter
receive antenna height using a broadband antenna from 30 MHz up to the upper frequency shown in
15.33(b)(1) depending on the highest frequency generated or used in the device or on which the
device operates or tunes. For frequencies above 1GHz, linearly polarized double ridge horn
antennas were used. For frequencies below 30 MHz, a calibrated loop antenna was used. When
exploratory measurements were necessary, they were performed at 1 meter test distance inside the
semi-anechoic chamber using broadband antennas, broadband amplifiers, and spectrum analyzers
to determine the frequencies and modes producing the maximum emissions. Sufficient time for the
EUT, support equipment, and test equipment was allowed in order for them to warm up to their
normal operating condition. The test set-up was placed on top of the 0.8 meter high, 1 x 1.5 meter
table. The EUT, support equipment, and interconnecting cables were arranged and manipulated to
maximize each emission. Appropriate precaution was taken to ensure that all emissions from the
EUT were maximized and investigated. The system configuration, mode of operation, if applicable,
turntable azimuth, and receive antenna height was noted for each frequency found.
Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized
broadband and horn antennas. The test setup was configured to the setup that produced the worst
case emissions. The spectrum analyzer was set to investigate all frequencies required for testing to
compare the highest radiated disturbances with respect to the specified limits. The turntable
containing the EUT was rotated through 360 degrees and the height of the receive antenna was
varied 1 to 4 meters and stopped at the azimuth and height producing the maximum emission. Each
emission was maximized by changing the orientation of the EUT through three orthogonal planes
and changing the polarity of the receive antenna, whichever produced the worst-case emissions.
According to 3dB beam-width of horn antenna, the horn antenna should be always directed to the
EUT when rising height.




FCC ID: XR3-MAX                                                                     Page Number: 11 of 29


                                                                          Report No.: 1606RSU02104



4.     TEST EQUIPMENT CALIBRATION DATE
Conducted Emissions – SR2
Instrument                   Manufacturer Type No.    Serial No.       Cali. Interval Cali. Due Date

EMI Test Receiver            R&S             ESR7     101209           1 year          2016/11/03
Two-Line V-Network           R&S             ENV216   101683           1 year          2016/11/03
Two-Line V-Network           R&S             ENV216   101684           1 year          2016/11/03
Temperature/Humidity Meter   Yuhuaze         HTC-2    MRTSUE06182      1 year          2016/12/20

Radiated Emission – AC2
Instrument                   Manufacturer Type No.    Serial No.       Cali. Interval Cali. Due Date

MXE EMI Receiver             Agilent         N9038A   MY51210182       1 year          2016/08/03
Microwave System Amplifier   Agilent         83017A   MY53270040       1 year          2017/03/29
TRILOG Antenna               Schwarzbeck VULB9162     9162-047         1 year          2016/11/07
Broad-Band Horn Antenna      Schwarzbeck BBHA9120D    9120D-1167       1 year          2016/11/07
Digitial Thermometer &
                             MingGao         ETH529   MRTSUE06170      1 year          2016/11/30
Hygromete


Software                           Version                         Function
e3                                 V8.3.5                          EMI Test Software




FCC ID: XR3-MAX                                                                 Page Number: 12 of
29


                                                                          Report No.: 1606RSU02104



5.    MEASUREMENT UNCERTAINTY
Where relevant, the following test uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed
at approximately the 95% confidence level using a coverage factor of k = 2.


AC Conducted Emission Measurement – SR2
     Measuring Uncertainty for a Level of Confidence of 95% (U=2Uc(y)):
     150kHz~30MHz: 3.5dB
Radiated Emission Measurement – AC2
     Measuring Uncertainty for a Level of Confidence of 95% (U=2Uc(y)):
     Horizontal: 30MHz~1GHz: 4.07dB
                  1GHz~18GHz: 4.16 dB
     Vertical:    30MHz~1GHz: 4.18 dB
                  1GHz~18GHz: 4.76 dB




FCC ID: XR3-MAX                                                                 Page Number: 13 of
29


                                                                   Report No.: 1606RSU02104



6.   TEST RESULT
6.1. Summary
Company Name:         ONYX INTERNATIONAL INC.
                      Mode 1: Charging + Reading + Playing Music
Test Mode:
                      Mode 2: USB Copy


     FCC Part Section(s)               Test Description               Test Result

             15.107                  Conducted Emissions                 Pass

             15.109                   Radiated Emissions                 Pass




FCC ID: XR3-MAX                                                         Page Number: 14 of
29


                                                                          Report No.: 1606RSU02104



6.2. Conducted Emission Measurement

  6.2.1.   Test Limit

                                       FCC Part 15.107 Limits

           Frequency                              QP                              AV
             (MHz)                              (dBμV)                          (dBμV)

           0.15 - 0.50                          66 - 56                         56 - 46

            0.50 - 5.0                            56                               46

             5.0 - 30                             60                               50

  Note 1: The lower limit shall apply at the transition frequencies.
  Note 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to
  0.5MHz.

  6.2.2.   Test Setup




FCC ID: XR3-MAX                                                                 Page Number: 15 of
29


                                                                                 Report No.: 1606RSU02104



     6.2.3.    Test Result of Conducted Emissions
 Site: SR2                                             Time: 2016/06/21 - 16:57
 Limit: FCC_Part15.107_CE_Class B                      Engineer: Line Chen
 Probe: ENV216_101683_Filter On                        Polarity: Line
 EUT: E-reader                                         Power: AC 120V/60Hz
 Test Mode 1




 No     Flag    Mark   Frequency   Measure   Reading    Over Limit      Limit      Factor      Type
                       (MHz)       Level     Level      (dB)            (dBuV)     (dB)
                                   (dBuV)    (dBuV)
 1                     0.154       53.141    42.401     -12.641         65.781     10.740      QP
 2                     0.154       41.282    30.543     -14.499         55.781     10.740      AV
 3                     0.190       47.434    37.405     -16.603         64.037     10.029      QP
 4                     0.190       38.388    28.359     -15.649         54.037     10.029      AV
 5                     0.542       47.905    37.760     -8.095          56.000     10.145      QP
 6              *      0.542       40.828    30.683     -5.172          46.000     10.145      AV
 7                     1.310       41.240    31.343     -14.760         56.000     9.897       QP
 8                     1.310       32.156    22.259     -13.844         46.000     9.897       AV
 9                     1.813       41.920    32.043     -14.080         56.000     9.878       QP
 10                    1.813       32.409    22.532     -13.591         46.000     9.878       AV
 11                    2.931       41.632    31.779     -14.368         56.000     9.854       QP
 12                    2.931       33.068    23.214     -12.932         46.000     9.854       AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).



FCC ID: XR3-MAX                                                                       Page Number: 16 of
29


                                                                               Report No.: 1606RSU02104




 Site: SR2                                             Time: 2016/06/21 - 17:03
 Limit: FCC_Part15.107_CE _ Class B                    Engineer: Line Chen
 Probe: ENV216_101683_Filter On                        Polarity: Neutral
 EUT: E-reader                                         Power: AC 120V/60Hz
 Test Mode 1




 No   Flag   Mark   Frequency    Measure     Reading    Over Limit    Limit       Factor     Type
                    (MHz)        Level       Level      (dB)          (dBuV)      (dB)
                                 (dBuV)      (dBuV)
 1                  0.154        51.859      41.143     -13.923       65.781      10.716     QP
 2                  0.154        36.011      25.295     -19.771       55.781      10.716     AV
 3                  0.194        45.987      35.965     -17.877       63.864      10.021     QP
 4                  0.194        30.587      20.566     -23.276       53.864      10.021     AV
 5           *      0.510        46.409      36.233     -9.591        56.000      10.176     QP
 6                  0.510        34.419      24.242     -11.581       46.000      10.176     AV
 7                  1.218        44.676      34.774     -11.324       56.000      9.901      QP
 8                  1.218        32.100      22.199     -13.900       46.000      9.901      AV
 9                  2.042        46.372      36.500     -9.628        56.000      9.872      QP
 10                 2.042        34.476      24.604     -11.524       46.000      9.872      AV
 11                 3.058        42.921      33.055     -13.079       56.000      9.866      QP
 12                 3.058        30.403      20.536     -15.597       46.000      9.866      AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).




FCC ID: XR3-MAX                                                                     Page Number: 17 of
29


                                                                                 Report No.: 1606RSU02104


 Site: SR2                                             Time: 2016/06/22 - 09:36
 Limit: FCC_Part15.107_CE_Class B                      Engineer: Line Chen
 Probe: ENV216_101683_Filter On                        Polarity: Line
 EUT: E-reader                                         Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency    Measure     Reading    Over Limit      Limit      Factor      Type
                    (MHz)        Level       Level      (dB)            (dBuV)     (dB)
                                 (dBuV)      (dBuV)
 1           *      0.162        46.048      35.951     -19.313         65.361     10.097      QP
 2                  0.162        31.862      21.765     -23.498         55.361     10.097      AV
 3                  0.218        33.987      24.042     -28.908         62.895     9.945       QP
 4                  0.218        19.008      9.063      -33.887         52.895     9.945       AV
 5                  0.570        26.701      16.571     -29.299         56.000     10.130      QP
 6                  0.570        15.441      5.311      -30.559         46.000     10.130      AV
 7                  0.762        18.500      8.469      -37.500         56.000     10.031      QP
 8                  0.762        6.497       -3.534     -39.503         46.000     10.031      AV
 9                  8.670        21.797      11.619     -38.203         60.000     10.178      QP
 10                 8.670        14.806      4.627      -35.194         50.000     10.178      AV
 11                 24.414       18.692      8.484      -41.308         60.000     10.208      QP
 12                 24.414       12.890      2.682      -37.110         50.000     10.208      AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).




FCC ID: XR3-MAX                                                                       Page Number: 18 of
29


                                                                               Report No.: 1606RSU02104




 Site: SR2                                             Time: 2016/06/22 - 09:40
 Limit: FCC_Part15.107_CE _ Class B                    Engineer: Line Chen
 Probe: ENV216_101683_Filter On                        Polarity: Neutral
 EUT: E-reader                                         Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency    Measure     Reading    Over Limit    Limit       Factor     Type
                    (MHz)        Level       Level      (dB)          (dBuV)      (dB)
                                 (dBuV)      (dBuV)
 1           *      0.166        46.137      36.066     -19.021       65.158      10.071     QP
 2                  0.166        35.758      25.687     -19.400       55.158      10.071     AV
 3                  0.186        42.162      32.127     -22.051       64.213      10.035     QP
 4                  0.186        27.558      17.523     -26.656       54.213      10.035     AV
 5                  0.222        32.942      22.962     -29.802       62.744      9.980      QP
 6                  0.222        19.547      9.567      -33.197       52.744      9.980      AV
 7                  0.566        24.502      14.352     -31.498       56.000      10.150     QP
 8                  0.566        11.235      1.086      -34.765       46.000      10.150     AV
 9                  8.650        19.279      9.082      -40.721       60.000      10.197     QP
 10                 8.650        12.495      2.298      -37.505       50.000      10.197     AV
 11                 17.746       18.464      8.331      -41.536       60.000      10.133     QP
 12                 17.746       10.712      0.579      -39.288       50.000      10.133     AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).




FCC ID: XR3-MAX                                                                     Page Number: 19 of
29


                                                                        Report No.: 1606RSU02104



6.3. Radiated Emission Measurement

  6.3.1.   Test Limit

                                       FCC Part 15.109 Limits

            Frequency                           Distance                      Level
              (MHz)                                (m)                      (dBμV/m)

              30 - 88                               3                           40

             88 - 216                               3                          43.5

            216 - 960                               3                           46

            Above 960                               3                           54

  Note 1: The lower limit shall apply at the transition frequency.
  Note 2: Distance refers to the distance in meters between the measuring instrument antenna and
           the closed point of any part of the device or system.
  Note 3: E field strength (dBμV/m) = 20 log E field strength (uV/m)



  6.3.2.   Test Setup

  30MHz ~ 1GHz Test Setup:




FCC ID: XR3-MAX                                                              Page Number: 20 of
29


                                                t=im                 (Antenna Tower)

                                                 l       Antenna
           EUT
                                                                         ;
                      mm              3 m
0.8 m

*       (Turntable)   ' ' ' | I | |

                                                                   Pre—Amplifier
                                                     perman        o y— @          R
                                       L    |


                                                                                     Report No.: 1606RSU02104



     6.3.3.    Test Result of Radiated Emissions
 Site: AC2                                                 Time: 2016/07/12 - 16:51
 Limit: FCC_Part15.109_RE(3m)_Class B                      Engineer: Line Chen
 Probe: VULB9162_0.03-8GHz                                 Polarity: Horizontal
 EUT: E-reader                                             Power: AC 120V/60Hz
 Test Mode 1




 No     Flag    Mark   Frequency   Measure    Reading    Over      Limit          Factor   Ant    Table   Type
                       (MHz)       Level      Level      Limit     (dBuV/m)       (dB)     Pos    Pos
                                   (dBuV/m)   (dBuV)     (dB)                              (cm)   (deg)
 1                     165.315     32.833     22.782     -10.667   43.500         10.051   100    107     QP
 2                     181.320     31.827     20.790     -11.673   43.500         11.037   100    201     QP
 3                     232.245     30.932     17.771     -15.068   46.000         13.161   100    193     QP
 4                     390.840     30.522     13.997     -15.478   46.000         16.526   100    177     QP
 5              *      480.080     38.668     20.671     -7.332    46.000         17.997   100    335     QP
 6                     709.000     33.005     11.261     -12.995   46.000         21.744   100    281     QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: XR3-MAX                                                                            Page Number: 22 of
29


                                                                                   Report No.: 1606RSU02104




 Site: AC2                                                 Time: 2016/07/12 - 16:51
 Limit: FCC_Part15.109_RE(3m)_Class B                      Engineer: Line Chen
 Probe: VULB9162_0.03-8GHz                                 Polarity: Vertical
 EUT: E-reader                                             Power: AC 120V/60Hz
 Test Mode 1




 No   Flag   Mark   Frequency   Measure     Reading      Over       Limit       Factor   Ant    Table   Type
                    (MHz)       Level       Level        Limit      (dBuV/m)    (dB)     Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                            (cm)   (deg)
 1                  57.160      24.248      9.932        -15.752    40.000      14.316   100    118     QP
 2           *      166.285     30.028      19.931       -13.472    43.500      10.097   100    102     QP
 3                  181.320     27.699      16.662       -15.801    43.500      11.037   100    209     QP
 4                  480.080     29.114      11.117       -16.886    46.000      17.997   100    347     QP
 5                  614.910     24.717      4.441        -21.283    46.000      20.276   100    67      QP
 6                  720.155     28.889      7.003        -17.111    46.000      21.886   100    278     QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: XR3-MAX                                                                          Page Number: 23 of
29


                                                                                     Report No.: 1606RSU02104


 Site: AC2                                                 Time: 2016/07/12 - 16:51
 Limit: FCC_Part15.109_RE(3m)_Class B                      Engineer: Line Chen
 Probe: VULB9162_0.03-8GHz                                 Polarity: Horizontal
 EUT: E-reader                                             Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency   Measure     Reading      Over      Limit          Factor   Ant    Table   Type
                    (MHz)       Level       Level        Limit     (dBuV/m)       (dB)     Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                              (cm)   (deg)
 1                  66.375      24.390      12.298       -15.610   40.000         12.092   100    247     QP
 2                  180.350     30.966      20.003       -12.534   43.500         10.962   100    214     QP
 3                  252.615     33.686      19.936       -12.314   46.000         13.750   100    56      QP
 4                  288.990     33.625      19.271       -12.375   46.000         14.353   100    162     QP
 5           *      395.980     42.967      26.300       -3.033    46.000         16.667   100    152     QP
 6                  415.090     39.079      22.118       -6.921    46.000         16.961   100    102     QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: XR3-MAX                                                                            Page Number: 24 of
29


                                                                                   Report No.: 1606RSU02104




 Site: AC2                                                 Time: 2016/07/12 - 16:51
 Limit: FCC_Part15.109_RE(3m)_Class B                      Engineer: Line Chen
 Probe: VULB9162_0.03-8GHz                                 Polarity: Vertical
 EUT: E-reader                                             Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency   Measure     Reading      Over       Limit       Factor   Ant    Table   Type
                    (MHz)       Level       Level        Limit      (dBuV/m)    (dB)     Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                            (cm)   (deg)
 1           *      36.790      33.019      19.782       -6.981     40.000      13.237   100    125     QP
 2                  47.460      30.332      15.362       -9.668     40.000      14.969   100    76      QP
 3                  108.085     27.130      14.118       -16.370    43.500      13.013   100    287     QP
 4                  180.350     30.080      19.117       -13.420    43.500      10.962   100    219     QP
 5                  395.690     33.983      17.328       -12.017    46.000      16.654   100    155     QP
 6                  415.090     32.252      15.291       -13.748    46.000      16.961   100    98      QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: XR3-MAX                                                                          Page Number: 25 of
29


                                                                                   Report No.: 1606RSU02104


 Site: AC2                                               Time: 2016/07/12 - 16:03
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Line Chen
 Probe: BBHA9120D_1-18GHz                                Polarity: Horizontal
 EUT: E-reader                                           Power: AC 120V/60Hz
 Test Mode 1




 No   Flag   Mark   Frequency    Measure    Reading    Over      Limit          Factor   Ant    Table   Type
                    (MHz)        Level      Level      Limit     (dBuV/m)       (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                              (cm)   (deg)
 1                  1884.000     33.685     38.942     -40.315   74.000         -5.256   100    261     PK
 2                  1884.500     24.268     29.521     -29.732   54.000         -5.253   100    270     AV
 3                  3235.500     36.141     38.612     -37.859   74.000         -2.471   100    118     PK
 4                  3236.000     26.896     29.371     -27.104   54.000         -2.475   100    123     AV
 5                  6474.000     40.473     33.368     -33.527   74.000         7.105    100    330     PK
 6           *      6474.500     31.096     23.983     -22.904   54.000         7.113    100    323     AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) – Pre_Amplifier Gain (dB).




FCC ID: XR3-MAX                                                                          Page Number: 26 of
29


                                                                                   Report No.: 1606RSU02104




 Site: AC2                                               Time: 2016/07/12 - 16:03
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Line Chen
 Probe: BBHA9120D_1-18GHz                                Polarity: Vertical
 EUT: E-reader                                           Power: AC 120V/60Hz
 Test Mode 1




 No   Flag   Mark   Frequency    Measure    Reading    Over       Limit       Factor   Ant    Table   Type
                    (MHz)        Level      Level      Limit      (dBuV/m)    (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                            (cm)   (deg)
 1                  1561.000     33.317     39.382     -40.683    74.000      -6.065   100    220     PK
 2                  1561.500     23.942     30.001     -30.058    54.000      -6.060   100    208     AV
 3                  6882.000     42.492     34.185     -31.508    74.000      8.307    100    313     AV
 4                  6882.500     33.324     25.016     -20.676    54.000      8.308    100    324     PK
 5                  9755.000     47.097     34.124     -26.903    74.000      12.973   100    69      PK
 6           *      9755.500     38.392     25.421     -15.608    54.000      12.970   100    76      AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) – Pre_Amplifier Gain (dB).




FCC ID: XR3-MAX                                                                         Page Number: 27 of
29


                                                                                   Report No.: 1606RSU02104


 Site: AC2                                               Time: 2016/07/12 - 16:08
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Line Chen
 Probe: BBHA9120D_1-18GHz                                Polarity: Horizontal
 EUT: E-reader                                           Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency    Measure    Reading    Over      Limit          Factor   Ant    Table   Type
                    (MHz)        Level      Level      Limit     (dBuV/m)       (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                              (cm)   (deg)
 1                  2394.000     34.904     37.568     -39.096   74.000         -2.664   100    78      PK
 2                  2394.500     25.007     27.672     -28.993   54.000         -2.665   100    85      AV
 3                  5131.000     37.011     33.857     -36.989   74.000         3.154    100    178     PK
 4                  5131.500     27.829     24.679     -26.171   54.000         3.150    100    183     AV
 5                  9228.000     45.246     32.111     -28.754   74.000         13.135   100    214     PK
 6           *      9228.500     36.334     23.217     -17.666   54.000         13.117   100    220     AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) – Pre_Amplifier Gain (dB).




FCC ID: XR3-MAX                                                                          Page Number: 28 of
29


                                                                                   Report No.: 1606RSU02104




 Site: AC2                                                Time: 2016/07/12 - 16:08
 Limit: FCC_Part15.109_RE(3m)_Class B                     Engineer: Line Chen
 Probe: BBHA9120D_1-18GHz                                 Polarity: Vertical
 EUT: E-reader                                            Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency    Measure    Reading     Over       Limit       Factor   Ant    Table   Type
                    (MHz)        Level      Level       Limit      (dBuV/m)    (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)      (dB)                            (cm)   (deg)
 1                  2292.000     35.143     37.270      -38.857    74.000      -2.127   100    117     PK
 2                  2292.500     26.405     28.532      -27.595    54.000      -2.127   100    121     AV
 3                  6151.000     40.191     34.411      -33.809    74.000      5.779    100    230     PK
 4                  6151.500     31.005     25.226      -22.995    54.000      5.779    100    224     AV
 5                  8803.000     44.648     32.921      -29.352    74.000      11.727   100    356     PK
 6           *      8803.500     35.061     23.336      -18.939    54.000      11.725   100    349     AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) – Pre_Amplifier Gain (dB).




                                                    The End

FCC ID: XR3-MAX                                                                         Page Number: 29 of
29



Document Created: 2017-12-11 23:38:34
Document Modified: 2017-12-11 23:38:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC