Test Report

FCC ID: XR3-KEPLER

Test Report

Download: PDF
FCCID_3092698

                                       MRT Technology (Suzhou) Co., Ltd                 Report No.: 1606RSU02004
    s                                  Phone: +86—512—66308358                          Report Version:         voz
                        ‘              Fax:       +86—512—66308368                      Issue Date:       08—09—2016
                                    Web:          www.mrt—cert.com




                         MEASUREMENT REPORT
                              FCC Part 15B


FCC ID:                         XR3—KEPLER

APPLICANT:                      ONYX INTERNATIONAL INC.



Application Type:               Certification
 Product:                       E—reader
 Model No.:                     Kepler, Kepler Pro, Kepler Lite, Da Vinci, ONYX BOOX

                                MONTE CRISTO, ONYX BOOX ROBINSON CRUSOE
 FCC Classification: FCC Class B Digital Device (JBP)
 FCC Rule Part(s):               FCC Part 15 Subpart B: 2016
 Test Procedure(s):             ANSI C63.4: 2014
 Test Date:                     June 17 ~ July 13, 2016



      .                            7                 g                \\\\\\"l"ll////
 Reviewed By                :      LQ,%\ Wiua                        §\\Q_/// /,2


                                   n
                                ———~_—_—_——____—

                                                                 ipeue
                                                                 ag _ —




 nomroveasy                       Mulicki                            zZ—os (ecensomed
                                              —       S          5 /—\ *z




                                 ( Marlin Ghen )                       "Srleg yAio*            cErTificATE23628.01




The test results relate only to the samples tested.
This equipment has been shown to be capable of compliance with the applicable technical standards as
indicated in the measurement report and was tested in accordance with the measurement procedures specified
in ANSI €63.4—2014. Test results reported herein relate only to the item(s) tested.
The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou)
Co., Ltd.
 FCC ID: XR3—KEPLER                                                                           Page Number: 1 of 29


                                                           Report No.: 1606RSU02004


                               Revision History

   Report No.        Version            Description               Issue Date

 1606RSU02004        Rev. 01             Initial report           08-05-2016

 1606RSU02004        Rev. 02         Added serial number          08-09-2016




FCC ID: XR3-KEPLER                                              Page Number: 2 of 29


                                                                                                             Report No.: 1606RSU02004


                                                           CONTENTS
Description                                                                                                                               Page
§2.1033 General Information ......................................................................................................... 4

1.     INTRODUCTION ..................................................................................................................... 5

      1.1.       Scope ........................................................................................................................... 5
      1.2.       MRT Test Location ........................................................................................................ 5

2.     PRODUCT INFORMATION ..................................................................................................... 6

      2.1.       Product Specification Subjective to this Report ............................................................. 6
      2.2.       Test Mode .................................................................................................................... 6
      2.3.       Test Configuration ........................................................................................................ 7
      2.4.       Test System Details ...................................................................................................... 9
      2.5.       Test Software ............................................................................................................... 9
      2.6.       EMI Suppression Device(s)/Modifications ..................................................................... 9

3.     DESCRIPTION OF TEST ...................................................................................................... 10

      3.1.       Evaluation Procedure ................................................................................................. 10
      3.2.       AC Line Conducted Emissions ................................................................................... 10
      3.3.       Radiated Emissions ..................................................................................................... 11

4.     TEST EQUIPMENT CALIBRATION DATE ............................................................................ 12

5.     MEASUREMENT UNCERTAINTY ......................................................................................... 13

6.     TEST RESULT ...................................................................................................................... 14

      6.1.       Summary .................................................................................................................... 14
      6.2.       Conducted Emission Measurement ............................................................................ 15
      6.2.1.        Test Limit ................................................................................................................ 15
      6.2.2.        Test Setup............................................................................................................... 15
      6.2.3.        Test Result of Conducted Emissions ....................................................................... 16
      6.3.       Radiated Emission Measurement ............................................................................... 20
      6.3.1.        Test Limit ................................................................................................................ 20
      6.3.2.        Test Setup............................................................................................................... 20
      6.3.3.        Test Result of Radiated Emissions .......................................................................... 22




FCC ID: XR3-KEPLER                                                                                                     Page Number: 3 of 29


                                                                       Report No.: 1606RSU02004


§2.1033 General Information
Applicant:                    ONYX INTERNATIONAL INC.
Applicant Address:            Room 102, 3rd Floor, No. 38 HongLou Road, LiWan District,
                              GuangZhou, China
Manufacturer:                 ONYX INTERNATIONAL INC.
Manufacturer Address:         Room 102, 3rd Floor, No. 38 HongLou Road, LiWan District,
                              GuangZhou, China
Test Site:                    MRT Technology (Suzhou) Co., Ltd
Test Site Address:            D8 Building, Youxin Industrial Park, No.2 Tian’edang Rd., Wuzhong
                              Economic Development Zone, Suzhou, China
MRT FCC Registration No.:     809388
FCC ID:                       XR3-KEPLER
Model No.:                    Kepler, Kepler Pro, Kepler Lite, Da Vinci, ONYX BOOX MONTE
                              CRISTO, ONYX BOOX ROBINSON CRUSOE
Test Device Serial No.:       N/A             Production      Pre-Production      Engineering


Test Facility / Accreditations
Measurements were performed at MRT Laboratory located in Tian’edang Rd., Suzhou, China.
 MRT facility is a FCC registered (MRT Reg. No. 809388) test facility with the site description
  report on file and has met all the requirements specified in Section 2.948 of the FCC Rules.
 MRT facility is an IC registered (MRT Reg. No. 11384A-1) test laboratory with the site
  description on file at Industry Canada.
 MRT facility is a VCCI registered (R-4179, G-814,
  C-4664, T-2206) test laboratory with the site description
  on file at VCCI Council.
 MRT Lab is accredited to ISO 17025 by the American
  Association for Laboratory Accreditation (A2LA) under
  the American Association for Laboratory Accreditation
  Program (A2LA Cert. No. 3628.01) in EMC,
  Telecommunications and Radio testing for FCC,
  Industry Canada, EU and TELEC Rules.




FCC ID: XR3-KEPLER                                                             Page Number: 4 of 29


                                                                            Report No.: 1606RSU02004



1.    INTRODUCTION
1.1. Scope
Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices
including intentional and/or unintentional radiators for compliance with the technical rules and
regulations of the Federal Communications Commission and the Industry Canada Certification and
Engineering Bureau.



1.2. MRT Test Location
The map below shows the location of the MRT LABORATORY, its proximity to the Taihu Lake.
These measurement tests were conducted at the MRT Technology (Suzhou) Co., Ltd. Facility
located at D8 Building, Youxin Industrial Park, No.2 Tian’edang Rd., Wuzhong Economic
Development Zone, Suzhou, China. The detailed description of the measurement facility was found
to be in compliance with the requirements of § 2.948 according to ANSI C63.4-2009 on September
30, 2013.




FCC ID: XR3-KEPLER                                                                 Page Number: 5 of 29


                                                                  Report No.: 1606RSU02004



2.    PRODUCT INFORMATION
2.1. Product Specification Subjective to this Report
Product Name            E-reader
                        Kepler, Kepler Pro, Kepler Lite, Da Vinci, ONYX BOOX MONTE CRISTO,
Model No.
                        ONYX BOOX ROBINSON CRUSOE
Wi-Fi Specification     802.11b/g/n-HT20
Bluetooth Version       v3.0 + HS, v4.0
Components
Adapter                 M/N: HKC0055010-2D
                        INPUT: 100-240V ~ 50/60Hz, 0.2A
                        OUTPUT: 5Vdc, 1.0A



2.2. Test Mode
Mode 1: Charging + Reading
Mode 2: USB Copy




FCC ID: XR3-KEPLER                                                     Page Number: 6 of 29


                                                                         Report No.: 1606RSU02004



2.3. Test Configuration
The EUT was tested per the guidance FCC Part 15 Subpart B: 2016 and ANSI C63.4: 2014 was
used to reference the appropriate EUT setup for radiated spurious emissions testing and AC line
conducted testing.

Connection Diagram (Mode 1)




FCC ID: XR3-KEPLER                                                             Page Number: 7 of 29


                                                         Report No.: 1606RSU02004


Connection Diagram (Mode 2)




Signal Cable Type             Signal Cable Description
A     USB Cable               Shielded, 0.5m
B     USB Cable               Shielded, 1.8m




FCC ID: XR3-KEPLER                                            Page Number: 8 of 29


                                                                            Report No.: 1606RSU02004



2.4. Test System Details
The types for all equipments, plus descriptions of all cables used in the tested system (including
inserted cards) are:
Product                 Manufacturer        Model No.       Serial No.         Power Cord
1     Notebook          Lenovo              E430c           MP-4CFX213/10 Non-Shielded, 1.8m
2     USB Mouse         DELL                MS111-T         N/A                N/A



2.5. Test Software
1   Setup the EUT and simulators as shown on above.
2   Turn on the power of all equipment.
    (1), Making EUT working on “Charging + Reading” Mode.
3
    (2), Making EUT working on “USB Copy” Mode.



2.6. EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and/or no modifications were made during testing.




FCC ID: XR3-KEPLER                                                                Page Number: 9 of 29


                                                                             Report No.: 1606RSU02004



3.    DESCRIPTION OF TEST
3.1. Evaluation Procedure
The measurement procedures described in the American National Standard for Methods of
Measurement of Radio-Noise Emission from Low-Voltage Electrical Equipment in the Range of 9kHz
to 40GHz (ANSI C63.4-2014) was used in the measurement of the E-reader
Deviation from measurement procedure…………………………….....................................None



3.2. AC Line Conducted Emissions
The line-conducted facility is located inside an 8'x4'x4' shielded enclosure. A 1m x 2m wooden table
80cm high is placed 40cm away from the vertical wall and 80cm away from the sidewall of the
shielded room. Two 10kHz-30MHz, 50Ω/50uH Line-Impedance Stabilization Networks (LISNs) are
bonded to the shielded room floor. Power to the LISNs is filtered by external high-current
high-insertion loss power line filters. These filters attenuate ambient signal noise from entering the
measurement lines. These filters are also bonded to the shielded enclosure.
The EUT is powered from one LISN and the support equipment is powered from the second LISN. If
the EUT is a DC-powered device, power will be derived from the source power supply it normally will
be powered from and this supply line(s) will be connected to the second LISN. All interconnecting
cables more than 1 meter were shortened to a 1 meter length by non-inductive bundling (serpentine
fashion) and draped over the back edge of the test table. All cables were at least 40cm above the
horizontal reference ground-plane. Power cables for support equipment were routed down to the
second LISN while ensuring that that cables were not draped over the second LISN.
Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to
warm up to their normal operating condition. The RF output of the LISN was connected to the
receiver and exploratory measurements were made to determine the frequencies producing the
maximum emission from the EUT. The receiver was scanned from 150 kHz to 30 MHz. The detector
function was set to peak mode for exploratory measurements while the bandwidth of the analyzer
was set to 9 kHz. The EUT, support equipment, and interconnecting cables were arranged and
manipulated to maximize each emission. Each emission was also maximized by varying: power lines,
the mode of operation or resolution, clock or data exchange speed, scrolling H pattern to the EUT
and/or support equipment whichever determined the worst-case emission. Once the worst case
emissions have been identified, the one EUT cable configuration/arrangement and mode of
operation that produced these emissions are used for final measurements on the same test site.
Line conducted emissions test results are shown in Section 6.2.




FCC ID: XR3-KEPLER                                                                 Page Number: 10 of
29


                                                                              Report No.: 1606RSU02004



3.3. Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final
measurements and exploratory measurements, when necessary. The measurement area is
contained within the semi-anechoic chamber which is shielded from any ambient interference. For
measurements above 1GHz absorbers are arranged on the floor between the turn table and the
antenna mast in such a way so as to maximize the reduction of reflections. For measurements below
1GHz, the absorbers are removed. An MF Model 210SS turntable is used for radiated measurement.
It is a continuously rotatable, remote controlled, metallic turntable and 2 meters (6.56 ft.) in diameter.
The turn table is flush with the raised floor of the chamber in order to maintain its function as a
ground plane. An 80cm high PVC support structure is placed on top of the turntable.
For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter
receive antenna height using a broadband antenna from 30 MHz up to the upper frequency shown in
15.33(b)(1) depending on the highest frequency generated or used in the device or on which the
device operates or tunes. For frequencies above 1GHz, linearly polarized double ridge horn
antennas were used. For frequencies below 30 MHz, a calibrated loop antenna was used. When
exploratory measurements were necessary, they were performed at 1 meter test distance inside the
semi-anechoic chamber using broadband antennas, broadband amplifiers, and spectrum analyzers
to determine the frequencies and modes producing the maximum emissions. Sufficient time for the
EUT, support equipment, and test equipment was allowed in order for them to warm up to their
normal operating condition. The test set-up was placed on top of the 0.8 meter high, 1 x 1.5 meter
table. The EUT, support equipment, and interconnecting cables were arranged and manipulated to
maximize each emission. Appropriate precaution was taken to ensure that all emissions from the
EUT were maximized and investigated. The system configuration, mode of operation, if applicable,
turntable azimuth, and receive antenna height was noted for each frequency found.
Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized
broadband and horn antennas. The test setup was configured to the setup that produced the worst
case emissions. The spectrum analyzer was set to investigate all frequencies required for testing to
compare the highest radiated disturbances with respect to the specified limits. The turntable
containing the EUT was rotated through 360 degrees and the height of the receive antenna was
varied 1 to 4 meters and stopped at the azimuth and height producing the maximum emission. Each
emission was maximized by changing the orientation of the EUT through three orthogonal planes
and changing the polarity of the receive antenna, whichever produced the worst-case emissions.
According to 3dB beam-width of horn antenna, the horn antenna should be always directed to the
EUT when rising height.




FCC ID: XR3-KEPLER                                                                   Page Number: 11 of
29


                                                                         Report No.: 1606RSU02004



4.     TEST EQUIPMENT CALIBRATION DATE
Conducted Emissions – SR2
Instrument                   Manufacturer Type No.   Serial No.      Cali. Interval Cali. Due Date

EMI Test Receiver            R&S          ESR7       101209          1 year        2016/11/03
Two-Line V-Network           R&S          ENV216     101683          1 year        2016/11/03
Two-Line V-Network           R&S          ENV216     101684          1 year        2016/11/03
Temperature/Humidity Meter   Yuhuaze      HTC-2      MRTSUE06182     1 year        2016/12/20

Radiated Emission – AC2
Instrument                   Manufacturer Type No.   Serial No.      Cali. Interval Cali. Due Date

MXE EMI Receiver             Agilent      N9038A     MY51210182      1 year        2016/08/03
Microwave System Amplifier   Agilent      83017A     MY53270040      1 year        2017/03/29
TRILOG Antenna               Schwarzbeck VULB9162    9162-047        1 year        2016/11/07
Broad-Band Horn Antenna      Schwarzbeck BBHA9120D   9120D-1167      1 year        2016/11/07
Digitial Thermometer &
                             MingGao      ETH529     MRTSUE06170     1 year        2016/11/30
Hygromete


Software                     Version                 Function
e3                           V8.3.5                  EMI Test Software




FCC ID: XR3-KEPLER                                                            Page Number: 12 of
29


                                                                          Report No.: 1606RSU02004



5.    MEASUREMENT UNCERTAINTY
Where relevant, the following test uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed
at approximately the 95% confidence level using a coverage factor of k = 2.


AC Conducted Emission Measurement – SR2
     Measuring Uncertainty for a Level of Confidence of 95% (U=2Uc(y)):
     150kHz~30MHz: 3.5dB
Radiated Emission Measurement – AC2
     Measuring Uncertainty for a Level of Confidence of 95% (U=2Uc(y)):
     Horizontal: 30MHz~1GHz: 4.07dB
                 1GHz~18GHz: 4.16 dB
     Vertical:   30MHz~1GHz: 4.18 dB
                 1GHz~18GHz: 4.76 dB




FCC ID: XR3-KEPLER                                                              Page Number: 13 of
29


                                                          Report No.: 1606RSU02004



6.   TEST RESULT
6.1. Summary
Company Name:         ONYX INTERNATIONAL INC.
                      Mode 1: Charging + Reading
Test Mode:
                      Mode 2: USB Copy


     FCC Part Section(s)              Test Description       Test Result

             15.107                 Conducted Emissions         Pass

             15.109                  Radiated Emissions         Pass




FCC ID: XR3-KEPLER                                             Page Number: 14 of
29


                                                                          Report No.: 1606RSU02004



6.2. Conducted Emission Measurement

  6.2.1.   Test Limit

                                       FCC Part 15.107 Limits

           Frequency                              QP                              AV
             (MHz)                              (dBμV)                          (dBμV)

           0.15 - 0.50                          66 - 56                         56 - 46

            0.50 - 5.0                            56                               46

             5.0 - 30                             60                               50

  Note 1: The lower limit shall apply at the transition frequencies.
  Note 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to
  0.5MHz.

  6.2.2.   Test Setup




FCC ID: XR3-KEPLER                                                               Page Number: 15 of
29


                                                                                 Report No.: 1606RSU02004



     6.2.3.    Test Result of Conducted Emissions
 Site: SR2                                             Time: 2016/06/21 - 11:35
 Limit: FCC_Part15.107_CE_Class B                      Engineer: Line Chen
 Probe: ENV216_101683_Filter On                        Polarity: Line
 EUT: E-reader                                         Power: AC 120V/60Hz
 Test Mode 1




 No     Flag    Mark   Frequency   Measure   Reading    Over Limit      Limit      Factor     Type
                       (MHz)       Level     Level      (dB)            (dBuV)     (dB)
                                   (dBuV)    (dBuV)
 1                     0.150       37.617    26.448     -28.383         66.000     11.168     QP
 2                     0.150       24.613    13.444     -31.387         56.000     11.168     AV
 3                     0.186       32.369    22.331     -31.844         64.213     10.039     QP
 4                     0.186       18.762    8.723      -35.452         54.213     10.039     AV
 5                     0.470       35.887    25.745     -20.627         56.514     10.142     QP
 6              *      0.470       30.219    20.077     -16.295         46.514     10.142     AV
 7                     0.525       32.820    22.667     -23.180         56.000     10.153     QP
 8                     0.525       25.779    15.626     -20.221         46.000     10.153     AV
 9                     1.780       33.545    23.667     -22.455         56.000     9.879      QP
 10                    1.780       24.401    14.522     -21.599         46.000     9.879      AV
 11                    6.816       35.742    25.592     -24.258         60.000     10.150     QP
 12                    6.816       27.818    17.668     -22.182         50.000     10.150     AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).



FCC ID: XR3-KEPLER                                                                    Page Number: 16 of
29


                                                                               Report No.: 1606RSU02004




 Site: SR2                                             Time: 2016/06/21 - 11:42
 Limit: FCC_Part15.107_CE _ Class B                    Engineer: Line Chen
 Probe: ENV216_101683_Filter On                        Polarity: Neutral
 EUT: E-reader                                         Power: AC 120V/60Hz
 Test Mode 1




 No   Flag   Mark   Frequency    Measure     Reading    Over Limit    Limit       Factor     Type
                    (MHz)        Level       Level      (dB)          (dBuV)      (dB)
                                 (dBuV)      (dBuV)
 1                  0.890        39.624      29.654     -16.376       56.000      9.970      QP
 2                  0.890        30.575      20.606     -15.425       46.000      9.970      AV
 3                  1.046        42.012      32.105     -13.988       56.000      9.907      QP
 4                  1.046        32.614      22.706     -13.386       46.000      9.907      AV
 5                  1.222        41.905      32.004     -14.095       56.000      9.901      QP
 6           *      1.222        32.914      23.013     -13.086       46.000      9.901      AV
 7                  1.343        41.751      31.854     -14.249       56.000      9.897      QP
 8                  1.343        32.575      22.679     -13.425       46.000      9.897      AV
 9                  5.881        40.354      30.242     -19.646       60.000      10.112     QP
 10                 5.881        31.747      21.635     -18.253       50.000      10.112     AV
 11                 22.900       39.712      29.466     -20.288       60.000      10.246     QP
 12                 22.900       20.401      10.154     -29.599       50.000      10.246     AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).




FCC ID: XR3-KEPLER                                                                   Page Number: 17 of
29


                                                                                 Report No.: 1606RSU02004


 Site: SR2                                             Time: 2016/06/21 - 19:23
 Limit: FCC_Part15.107_CE_Class B                      Engineer: Line Chen
 Probe: ENV216_101683_Filter On                        Polarity: Line
 EUT: E-reader                                         Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency    Measure     Reading    Over Limit      Limit      Factor     Type
                    (MHz)        Level       Level      (dB)            (dBuV)     (dB)
                                 (dBuV)      (dBuV)
 1                  0.150        38.696      27.527     -27.304         66.000     11.168     QP
 2                  0.150        26.110      14.941     -29.890         56.000     11.168     AV
 3           *      0.170        43.446      33.369     -21.514         64.960     10.078     QP
 4                  0.170        28.377      18.300     -26.583         54.960     10.078     AV
 5                  0.234        32.264      22.313     -30.043         62.307     9.951      QP
 6                  0.234        21.052      11.101     -31.255         52.307     9.951      AV
 7                  0.554        24.452      14.314     -31.548         56.000     10.139     QP
 8                  0.554        12.567      2.428      -33.433         46.000     10.139     AV
 9                  0.762        18.410      8.379      -37.590         56.000     10.031     QP
 10                 0.762        5.671       -4.360     -40.329         46.000     10.031     AV
 11                 8.446        21.845      11.669     -38.155         60.000     10.176     QP
 12                 8.446        14.270      4.094      -35.730         50.000     10.176     AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).




FCC ID: XR3-KEPLER                                                                    Page Number: 18 of
29


                                                                               Report No.: 1606RSU02004




 Site: SR2                                             Time: 2016/06/21 - 20:11
 Limit: FCC_Part15.107_CE _ Class B                    Engineer: Line Chen
 Probe: ENV216_101683_Filter On                        Polarity: Neutral
 EUT: E-reader                                         Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency    Measure     Reading    Over Limit    Limit       Factor     Type
                    (MHz)        Level       Level      (dB)          (dBuV)      (dB)
                                 (dBuV)      (dBuV)
 1           *      0.174        44.377      34.321     -20.390       64.767      10.057     QP
 2                  0.174        32.261      22.205     -22.506       54.767      10.057     AV
 3                  0.218        24.925      14.944     -37.970       62.895      9.981      QP
 4                  0.218        6.071       -3.911     -46.824       52.895      9.981      AV
 5                  0.558        25.535      15.381     -30.465       56.000      10.154     QP
 6                  0.558        15.005      4.851      -30.995       46.000      10.154     AV
 7                  1.370        18.040      8.145      -37.960       56.000      9.895      QP
 8                  1.370        8.446       -1.449     -37.554       46.000      9.895      AV
 9                  8.518        18.869      8.669      -41.131       60.000      10.199     QP
 10                 8.518        11.788      1.589      -38.212       50.000      10.199     AV
 11                 25.762       22.095      11.780     -37.905       60.000      10.316     QP
 12                 25.762       16.446      6.131      -33.554       50.000      10.316     AV
Note: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).




FCC ID: XR3-KEPLER                                                                   Page Number: 19 of
29


                                                                        Report No.: 1606RSU02004



6.3. Radiated Emission Measurement

  6.3.1.   Test Limit

                                       FCC Part 15.109 Limits

            Frequency                           Distance                      Level
              (MHz)                                (m)                      (dBμV/m)

              30 - 88                               3                           40

             88 - 216                               3                          43.5

            216 - 960                               3                           46

            Above 960                               3                           54

  Note 1: The lower limit shall apply at the transition frequency.
  Note 2: Distance refers to the distance in meters between the measuring instrument antenna and
           the closed point of any part of the device or system.
  Note 3: E field strength (dBμV/m) = 20 log E field strength (uV/m)



  6.3.2.   Test Setup

  30MHz ~ 1GHz Test Setup:




FCC ID: XR3-KEPLER                                                            Page Number: 20 of
29


                                1~4 m               (Antenna Tower)
                                  l     Antenna
           EUT                            D— |—=
18
0.8 m                 ,m   3M   ——————P                  |
 |      (Turntable)   '.“'..“..“‘.'


                                                  Pre —Amplifier

                                                     s


                                                                                     Report No.: 1606RSU02004



     6.3.3.    Test Result of Radiated Emissions
 Site: AC2                                                 Time: 2016/07/12 - 16:50
 Limit: FCC_Part15.109_RE(3m)_Class B                      Engineer: Line Chen
 Probe: VULB9162_0.03-8GHz                                 Polarity: Horizontal
 EUT: E-reader                                             Power: AC 120V/60Hz
 Test Mode 1




 No     Flag    Mark   Frequency   Measure    Reading    Over      Limit          Factor   Ant    Table   Type
                       (MHz)       Level      Level      Limit     (dBuV/m)       (dB)     Pos    Pos
                                   (dBuV/m)   (dBuV)     (dB)                              (cm)   (deg)
 1                     121.665     37.591     26.552     -5.909    43.500         11.039   100    78      QP
 2                     162.405     23.605     13.667     -19.895   43.500         9.938    100    114     QP
 3              *      203.145     39.448     27.116     -4.052    43.500         12.333   100    167     QP
 4                     243.400     36.861     23.337     -9.139    46.000         13.524   100    303     QP
 5                     284.140     35.656     21.392     -10.344   46.000         14.264   100    46      QP
 6                     365.630     26.032     9.936      -19.968   46.000         16.096   100    204     QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: XR3-KEPLER                                                                         Page Number: 22 of
29


                                                                                   Report No.: 1606RSU02004




 Site: AC2                                                 Time: 2016/07/12 - 16:50
 Limit: FCC_Part15.109_RE(3m)_Class B                      Engineer: Line Chen
 Probe: VULB9162_0.03-8GHz                                 Polarity: Vertical
 EUT: E-reader                                             Power: AC 120V/60Hz
 Test Mode 1




 No   Flag   Mark   Frequency   Measure     Reading      Over       Limit       Factor   Ant    Table   Type
                    (MHz)       Level       Level        Limit      (dBuV/m)    (dB)     Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                            (cm)   (deg)
 1                  47.460      31.602      16.632       -8.398     40.000      14.969   100    32      QP
 2                  67.345      29.096      17.331       -10.904    40.000      11.765   100    223     QP
 3                  121.665     36.571      25.532       -6.929     43.500      11.039   100    80      QP
 4           *      203.145     38.993      26.661       -4.507     43.500      12.333   100    163     QP
 5                  243.400     34.641      21.117       -11.359    46.000      13.524   100    310     QP
 6                  284.140     31.525      17.261       -14.475    46.000      14.264   100    51      QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: XR3-KEPLER                                                                       Page Number: 23 of
29


                                                                                     Report No.: 1606RSU02004


 Site: AC2                                                 Time: 2016/07/12 - 16:50
 Limit: FCC_Part15.109_RE(3m)_Class B                      Engineer: Line Chen
 Probe: VULB9162_0.03-8GHz                                 Polarity: Horizontal
 EUT: E-reader                                             Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency   Measure     Reading      Over      Limit          Factor   Ant    Table   Type
                    (MHz)       Level       Level        Limit     (dBuV/m)       (dB)     Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                              (cm)   (deg)
 1                  121.665     38.155      27.116       -5.345    43.500         11.039   100    82      QP
 2                  162.405     35.470      25.532       -8.030    43.500         9.938    100    108     QP
 3           *      203.145     38.994      26.662       -4.506    43.500         12.333   100    161     QP
 4                  284.140     36.381      22.117       -9.619    46.000         14.264   100    47      QP
 5                  365.620     33.213      17.117       -12.787   46.000         16.096   100    202     QP
 6                  480.080     32.268      14.271       -13.732   46.000         17.997   100    331     QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: XR3-KEPLER                                                                         Page Number: 24 of
29


                                                                                   Report No.: 1606RSU02004




 Site: AC2                                                 Time: 2016/07/12 - 16:50
 Limit: FCC_Part15.109_RE(3m)_Class B                      Engineer: Line Chen
 Probe: VULB9162_0.03-8GHz                                 Polarity: Vertical
 EUT: E-reader                                             Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency   Measure     Reading      Over       Limit       Factor   Ant    Table   Type
                    (MHz)       Level       Level        Limit      (dBuV/m)    (dB)     Pos    Pos
                                (dBuV/m)    (dBuV)       (dB)                            (cm)   (deg)
 1                  80.925      20.917      11.398       -19.083    40.000      9.519    100    192     QP
 2                  121.665     34.942      23.903       -8.558     43.500      11.039   100    85      QP
 3                  162.405     29.266      19.328       -14.234    43.500      9.938    100    110     QP
 4           *      203.145     38.114      25.782       -5.386     43.500      12.333   100    156     QP
 5                  480.080     31.779      13.782       -14.221    46.000      17.997   100    329     QP
 6                  798.725     28.382      5.536        -17.618    46.000      22.846   100    221     QP
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: XR3-KEPLER                                                                       Page Number: 25 of
29


                                                                                   Report No.: 1606RSU02004


 Site: AC2                                               Time: 2016/07/12 - 15:55
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Line Chen
 Probe: BBHA9120D_1-18GHz                                Polarity: Horizontal
 EUT: E-reader                                           Power: AC 120V/60Hz
 Test Mode 1




 No   Flag   Mark   Frequency    Measure    Reading    Over      Limit          Factor   Ant    Table   Type
                    (MHz)        Level      Level      Limit     (dBuV/m)       (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                              (cm)   (deg)
 1                  2402.500     34.305     36.990     -39.695   74.000         -2.685   100    136     PK
 2                  2403.000     25.087     27.773     -28.913   54.000         -2.687   100    139     AV
 3                  5165.000     37.406     34.418     -36.594   74.000         2.988    100    203     PK
 4                  5165.500     28.542     25.552     -25.458   54.000         2.990    100    217     AV
 5                  7732.000     43.324     32.848     -30.676   74.000         10.477   100    339     PK
 6           *      7732.500     34.483     24.008     -19.517   54.000         10.475   100    347     AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) – Pre_Amplifier Gain (dB).




FCC ID: XR3-KEPLER                                                                       Page Number: 26 of
29


                                                                                   Report No.: 1606RSU02004




 Site: AC2                                               Time: 2016/07/12 - 15:56
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Line Chen
 Probe: BBHA9120D_1-18GHz                                Polarity: Vertical
 EUT: E-reader                                           Power: AC 120V/60Hz
 Test Mode 1




 No   Flag   Mark   Frequency    Measure    Reading    Over       Limit       Factor   Ant    Table   Type
                    (MHz)        Level      Level      Limit      (dBuV/m)    (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                            (cm)   (deg)
 1                  1952.000     33.467     38.349     -40.533    74.000      -4.881   100    72      PK
 2                  1952.500     25.129     30.003     -28.871    54.000      -4.874   100    93      AV
 3                  5156.500     37.710     34.664     -36.290    74.000      3.046    100    302     PK
 4                  5157.000     27.271     24.228     -26.729    54.000      3.043    100    307     AV
 5                  7919.000     43.810     33.193     -30.190    74.000      10.617   100    221     PK
 6           *      7919.500     35.498     24.882     -18.502    54.000      10.617   100    234     AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) – Pre_Amplifier Gain (dB).




FCC ID: XR3-KEPLER                                                                      Page Number: 27 of
29


                                                                                   Report No.: 1606RSU02004


 Site: AC2                                               Time: 2016/07/12 - 15:59
 Limit: FCC_Part15.109_RE(3m)_Class B                    Engineer: Line Chen
 Probe: BBHA9120D_1-18GHz                                Polarity: Horizontal
 EUT: E-reader                                           Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency    Measure    Reading    Over      Limit          Factor   Ant    Table   Type
                    (MHz)        Level      Level      Limit     (dBuV/m)       (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)     (dB)                              (cm)   (deg)
 1                  2734.000     34.613     36.920     -39.387   74.000         -2.307   100    189     PK
 2                  2734.500     24.808     27.118     -29.192   54.000         -2.310   100    175     AV
 3                  5726.000     38.318     34.188     -35.682   74.000         4.131    100    271     PK
 4                  5726.500     29.858     25.715     -24.142   54.000         4.143    100    254     AV
 5                  9296.000     44.822     32.053     -29.178   74.000         12.769   100    82      PK
 6           *      9296.500     35.882     23.117     -18.118   54.000         12.765   100    90      AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) – Pre_Amplifier Gain (dB).




FCC ID: XR3-KEPLER                                                                       Page Number: 28 of
29


                                                                                   Report No.: 1606RSU02004




 Site: AC2                                                Time: 2016/07/12 - 16:01
 Limit: FCC_Part15.109_RE(3m)_Class B                     Engineer: Line Chen
 Probe: BBHA9120D_1-18GHz                                 Polarity: Vertical
 EUT: E-reader                                            Power: AC 120V/60Hz
 Test Mode 2




 No   Flag   Mark   Frequency    Measure    Reading     Over       Limit       Factor   Ant    Table   Type
                    (MHz)        Level      Level       Limit      (dBuV/m)    (dB)     Pos    Pos
                                 (dBuV/m)   (dBuV)      (dB)                            (cm)   (deg)
 1                  2334.500     34.264     36.584      -39.736    74.000      -2.319   100    118     PK
 2                  2335.000     25.033     27.361      -28.967    54.000      -2.328   100    123     AV
 3                  6287.000     39.735     33.750      -34.265    74.000      5.985    100    232     PK
 4                  6287.500     30.860     24.882      -23.140    54.000      5.978    100    241     AV
 5                  9347.000     44.839     32.422      -29.161    74.000      12.418   100    78      PK
 6           *      9347.500     36.358     23.927      -17.642    54.000      12.432   100    85      AV
Note: Measure Level (dBμV/m) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m) – Pre_Amplifier Gain (dB).