Test report

FCC ID: XPYSARAG350

Test Report

Download: PDF
FCCID_2055579

 FCC ID: XPYSARAG350           IC: 8595A-SARAG350                 Report No: T130724W03-D


FCC 47 CFR PART 15 SUBPART B & IC ICES-003
              TEST REPORT
                                          for

                                        Module

                                 MODEL: SARA-G310

                                 Test Report Number:
                                   T130724W03-D

                                       Issued for

                                      u-blox AG
                  Zuercherstrasse 68, 8800 Thalwil, Switzerland

                                       Issued By:

                        Compliance Certification Services Inc.
                                  Wugu Laboratory
                         No.11, Wugong 6th Rd., Wugu Dist.,
                        New Taipei City 24891, Taiwan. (R.O.C.)
                               TEL: 886-2-2299-9720
                                FAX: 886-2-2299-9721
                              E-Mail: service@ccsrf.com
                              Issued Date: August 2, 2013




Note: This report shall not be reproduced except in full, without the written approval of
Compliance Certification Services Inc. This document may be altered or revised by
Compliance Certification Services Inc. personnel only, and shall be noted in the revision
section of the document. The client should not use it to claim product endorsement by
TAF, A2LA, NIST or any government agencies. The test results in the report only apply
to the tested sample.


    Page 1 / 36


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                            Report No: T130724W03-D



                                                Revision History
                    Issue                                                                     Effect
 Rev.                Date                                 Revisions                           Page        Revised By
   00        August 2, 2013            Initial Issue                                           ALL        Kelly Cheng




                                                        Page 2
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


    FCC ID: XPYSARAG350                          IC: 8595A-SARAG350                                   Report No: T130724W03-D


                                                 TABLE OF CONTENTS
1        TEST RESULT CERTIFICATION .....................................................................................4
2        EUT DESCRIPTION ..........................................................................................................5
3        TEST METHODOLOGY ....................................................................................................6
 3.1.    DECISION OF FINAL TEST MODE ..................................................................................6
 3.2.    EUT SYSTEM OPERATION .............................................................................................6
4        SETUP OF EQUIPMENT UNDER TEST ..........................................................................7
 4.1.    DESCRIPTION OF SUPPORT UNITS ..............................................................................7
 4.2.    CONFIGURATION OF SYSTEM UNDER TEST ...............................................................8
5        FACILITIES AND ACCREDITATIONS .............................................................................9
 5.1.    FACILITIES .......................................................................................................................9
 5.2.    ACCREDITATIONS ...........................................................................................................9
 5.3.    MEASUREMENT UNCERTAINTY ..................................................................................10
6        CONDUCTED EMISSION MEASUREMENT ..................................................................11
 6.1.    LIMITS OF CONDUCTED EMISSION MEASUREMENT ...............................................11
 6.2.    TEST INSTRUMENTS ....................................................................................................11
 6.3.    TEST PROCEDURES .....................................................................................................12
 6.4.    TEST SETUP ..................................................................................................................13
 6.5.    DATA SAMPLE: ..............................................................................................................13
 6.6.    TEST RESULTS ..............................................................................................................14
7        RADIATED EMISSION MEASUREMENT ......................................................................16
 7.1.    LIMITS OF RADIATED EMISSION MEASUREMENT ....................................................16
 7.2.    TEST INSTRUMENTS ....................................................................................................18
 7.3.    TEST PROCEDURES .....................................................................................................19
 7.4.    TEST SETUP ..................................................................................................................20
 7.5.    DATA SAMPLE ...............................................................................................................21
 7.6.    TEST RESULTS ..............................................................................................................22
8        PHOTOGRAPHS OF THE TEST CONFIGURATION .....................................................34




                                                                Page 3
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                            Report No: T130724W03-D



1 TEST RESULT CERTIFICATION
        Product:      Module

           Model: SARA-G310

           Brand: u-blox
      Applicant:     u-blox AG
                     Zuercherstrasse 68, 8800 Thalwil, Switzerland
  Manufacturer:      u-blox AG
                     Zuercherstrasse 68, 8800 Thalwil, Switzerland
          Tested:     January 26 ~ August 02, 2013

  Test Voltage:       120VAC, 60Hz


                                                      EMISSION
             Standard                               Item                  Result                   Remarks

FCC 47 CFR Part 15 Subpart B,           Conducted (Power Port)              PASS               Meet Class B limit
ICES-003 Issue 5-2012
ANSI C63.4-2009                                  Radiated                   PASS               Meet Class B limit


Note: 1. The statements of test result on the above are decided by the request of test standard
         only; the measurement uncertainties are not factored into this compliance determination.
      2. The information of measurement uncertainty is available upon the customer’s request.

                                      Deviation from Applicable Standard

                                                          None


The above equipment has been tested by Compliance Certification Services Inc., and
found compliance with the requirements set forth in the technical standards mentioned
above. The results of testing in this report apply only to the product/system, which was
tested. Other similar equipment will not necessarily produce the same results due to
production tolerance and measurement uncertainties.

Approved by:                                                   Reviewed by:




Gary Wu                                                        Gina Lo
Section Manager                                                Section Manager




                                                        Page 4
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                            Report No: T130724W03-D


2 EUT DESCRIPTION

Product                                     Module


Brand Name                                  u-blox


Model                                       SARA-G310


Applicant                                   u-blox AG


Identify Number                             T130724W03


Received Date                               July 24, 2013


EUT Power Rating                            Powered from Power Adapter


Power Adapter Manufacturer GOOBAY                                Model NTS 30W Eup5-12

Power Adapter Power Rating For NTS 30W Eup5-12
                           I/P: 100-240V, 800mA, 50-60Hz
                           O/P: 5 ~12V, 4A~2.50A
                                            Unshielded, 1.8m (Detachable)
AC Power Cord Type
                                            with a core at Power Adapter

DC Power Cable Type                         Unshielded, 1.8m (Detachable) to Power Adapter



I/O Port
          I/O PORT TYPES                                      Q’TY                           TESTED WITH

1. Single Port                                                   1                                     1
Remark: Client consigns only one sample to test (model number: SARA-G310). Therefore, the testing Lab.
        just guarantees the unit, which has been tested.




                                                        Page 5
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                            Report No: T130724W03-D



3 TEST METHODOLOGY
3.1. DECISION OF FINAL TEST MODE
1.    The following test modes were scanned during the preliminary test:
        Pre-Test Mode
        Mode 1: Normal Operation GSM 900
        Mode 2: Normal Operation GSM 1800
        Mode 3: Normal Operation IDLE


2.    After the preliminary scan, the following test mode was found to produce the
      highest emission level.
        Final Test Mode
                          Conducted Emission                 Mode 1
        Emission
                          Radiated Emission                  Mode 1-3

      Then, the above highest emission mode of the configuration of the EUT and cable
      was chosen for all final test items.

3.2. EUT SYSTEM OPERATION
       1. Setup the EUT and simulators as shown on 4.2.
       2. Turn on the power of all equipment.
       3. Turn on the Terminal and Enter the script.
       4. Receiving analog base station 2G connection and sustained action.
       5. Adjust to the test mode and begin the test.
       Note: Test program is self-repeating throughout the test.




                                                        Page 6
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                              Report No: T130724W03-D


4 SETUP OF EQUIPMENT UNDER TEST
4.1. DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or support
units. The following support units or accessories were used to form a representative test configuration
during the tests.

 No.      Equipment          Trade Name            Model No.           Serial No.          FCC ID          Power Cord

  1.        Module              UBlox                N/A                  N/A               N/A                N/A

  2.     GSM Antenna             N/A                 N/A                  N/A               N/A                N/A

  3.       SIM Card              N/A                 N/A                  N/A               N/A                N/A

        Universal Radio
        Communication
  4.                             R&S               CMU200               101245              N/A         Unshielded, 1.8m
             Tester
           (Remote)



 No.             Cable Name                 Unit            Shielded             Length             With Core

 (A)             Single Cable                 1       ■Shielded, ■Non            1.8   m      With Core×      , ■Non



Note: Grounding was established in accordance with the manufacturer’s requirements and conditions
for the intended use.




                                                           Page 7
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D


4.2. CONFIGURATION OF SYSTEM UNDER TEST



                                                  1. Module

                                                     EUT




                          3. SIM Card                       A




                                                     2. Antenna




                                                                                          4. Universal Radio
                                                                                         Communication Tester
                                                                                              (Remote)




                                                       Page 8
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D


5 FACILITIES AND ACCREDITATIONS
5.1. FACILITIES
All measurement facilities used to collect the measurement data are located at:
   No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.)
   No.139, Wugong Rd., Wugu Dist., New Taipei City 24891, Taiwan (R.O.C.)
   No.81-1, Lane 210, Bade 2nd Rd., Lujhu Township, Taoyuan County 33841, TAIWAN, R.O.C.
   No.163-1, Jhongsheng Rd., Sindian City, Taipei County 23151, Taiwan.

The sites are constructed in conformance with the requirements of ANSI C63.4 and
CISPR 22. All receiving equipment conforms to CISPR 16-1-1, CISPR 16-1-2, CISPR
16-1-3, CISPR 16-1-4, CISPR 16-1-5.

5.2. ACCREDITATIONS
Our laboratories are accredited and approved by the following approval agencies
according to ISO/IEC 17025.
                                 Taiwan                    TAF (TAF 1309)
                                 USA                       A2LA (0824.01)
The measuring facility of laboratories has been authorized or registered by the following
approval agencies.
  Canada                  Industry Canada
                          (3M Semi Anechoic Chamber: IC 2324G-1 / IC 2324G-2 / 2324J-1 /
                          2324J-2 to perform)
  Norway                  Nemko
  Japan                   VCCI
                          966 Chamber C:
                          Radiated emissions: 30 MHz -1000 MHz: R-3282 / Above 1GHz: G-146
                          10M Chamber:
                          Radiated emissions: 30 MHz -1000 MHz: R-3283 / Above 1GHz: G-147
                          Conducted Emission B: C-3700 / T-1839
  USA                     FCC
                          (3M Semi Anechoic Chamber (FCC MRA: TW1039) to perform FCC
                          Part 15 measurements)
Copies of granted accreditation certificates are available for downloading from our web
site, http:///www.ccsrf.com




                                                        Page 9
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D


5.3. MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for
tests performed on the EUT as specified in CISPR 16-4-2:


            Measurement                             Frequency                             Uncertainty
        Conducted emissions                        9kHz~30MHz                             ±1.2575 dB
                                                    30~200MHz                             ±3.9163 dB
         Radiated emissions                       200~1000MHz                             ±3.9030 dB
                                                   Above 1GHz                             ±2.5208 dB
        This uncertainty represents an expanded uncertainty expressed at approximately the 95%
        confidence level using a coverage factor of k=2.
        Consistent with industry standard (e.g. CISPR 22:2008, clause 11, Measurement Uncertainty)
        determining compliance with the limits shall be base on the results of the compliance
        measurement. Consequently the measure emissions being less than the maximum allowed
        emission result in this be a compliant test or passing test.
        The acceptable measurement uncertainty value without requiring revision of the compliance
        statement is base on conducted and radiated emissions being less than UCISPR which is
        3.6dB and 5.2dB respectively. CCS values (called ULab in CISPR 16-4-2) is less than UCISPR
        as shown in the table above. Therefore, MU need not be considered for compliance.




                                                        Page 10
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D



6 CONDUCTED EMISSION MEASUREMENT
6.1. LIMITS OF CONDUCTED EMISSION MEASUREMENT
                                         Class A (dBuV)                               Class B (dBuV)
 FREQUENCY (MHz)
                               Quasi-peak             Average              Quasi-peak                 Average
       0.15 - 0.5                   79                    66                  66 - 56                  56 - 46
       0.50 - 5.0                   73                    60                     56                       46
       5.0 - 30.0                   73                    60                     60                       50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range 0.15 to 0.50 MHz.
(3) All emanations from a class A/B digital device or system, including any network of conductors and
    apparatus connected thereto, shall not exceed the level of field strengths specified above.

6.2. TEST INSTRUMENTS
                                       Conducted Emission Room # B
Name of Equipment Manufacturer                            Model               Serial Number          Calibration Due
   EMI Test Receiver               R&S                     ESCI                    101073                07/31/2013
          LISN                     R&S                    ENV216                   101054                06/05/2014
        LISN                SCHWARZBECK                 NSLK 8127                 8127-541               12/10/2013
  Capacitive Voltage
                                   FCC                   F-CVP-1                   100185                03/24/2014
       Probe
      Test S/W                                                     CCS-3A1-CE

Note:
1.   The calibration interval of the above test instruments is 12 months and the calibrations are traceable
     to NML/ROC and NIST/USA.




                                                        Page 11
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D




6.3. TEST PROCEDURES                             (please refer to measurement standard or CCS SOP PA-031)

Procedure of Preliminary Test
   z     The EUT and support equipment, if needed, were set up as per the test
       configuration to simulate typical usage per the user’s manual. When the EUT is a
       tabletop system, a wooden table with a height of 0.8 meters is used and is placed
       on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the
       ground plane used). When the EUT is a floor standing equipment, it is placed on the
       ground plane, which has a 12 mm non-conductive covering to insulate the EUT from
       the ground plane.
   z    All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
   z     The test equipment EUT installed by AC 120VAC/60Hz main power, through a
       Line Impedance Stabilization Network (LISN), which was supplied power source
       and was grounded to the ground plane.
   z    All support equipment power by from a second LISN.
   z     The test program of the EUT was started. Emissions were measured on each
       current carrying line of the EUT using an EMI Test Receiver connected to the LISN
       powering the EUT.
   z    The Receiver scanned from 150kHz to 30MHz for emissions in each of the test
       modes.
   z    During the above scans, the emissions were maximized by cable manipulation.
   z    The test mode(s) described in Item 3.1 were scanned during the preliminary test.
   z     After the preliminary scan, we found the test mode described in Item 3.1
       producing the highest emission level.
   z    The worst configuration of EUT and cable of the above highest emission level
       were recorded for reference of the final test.
Procedure of Final Test
   z     EUT and support equipment were set up on the test bench as per the
       configuration with highest emission level in the preliminary test.
   z     A scan was taken on both power lines, Line 1 and Line 2, recording at least the six
       highest emissions. Emission frequency and amplitude were recorded into a
       computer in which correction factors were used to calculate the emission level and
       compare reading to the applicable limit.
   z    The test data of the worst-case condition(s) was recorded.




                                                        Page 12
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                        IC: 8595A-SARAG350                               Report No: T130724W03-D


6.4. TEST SETUP

                                                    Vert. reference plane

                                                                                                    EMI receiver




                        40cm
                                       EUT




                                                             80cm




               LISN
                                                                     Reference ground plane



   z     For the actual test configuration, please refer to the related item – Photographs of
       the Test Configuration.



6.5. DATA SAMPLE:
            QuasiPeak   Average   Correctrion   QuasiPeak    Average    QuasiPeak.   Average   QuasiPeak   Average
Frequency
             reading    reading     factor        result      result      limit       limit     margin     margin    Remark
  (MHz)
             (dBuV)     (dBuV)       (dB)        (dBuV)      (dBuV)      (dBuV)      (dBuV)      (dB)       (dB)

  x.xx       43.95      33.00       10.00        53.95       43.00          56.00    46.00      -2.05      -3.00     Pass

Frequency (MHz)                = Emission frequency in MHz
Reading (dBuV)                 = Uncorrected Analyzer/Receiver reading + Insertion loss of LISN, if it > 0.5
dB
Correction Factor (dB)         = LISN Factor + Cable Loss
Result (dBuV)                  = Raw reading converted to dBuV and CF added
Limit (dBuV)                   = Limit stated in standard
Margin (dB)                    = Result (dBuV) – Limit (dBuV)




                                                         Page 13
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


  FCC ID: XPYSARAG350                          IC: 8595A-SARAG350                                Report No: T130724W03-D


 6.6. TEST RESULTS
                                               CCS Conduction Test

Model No.                        SARA-G310                       Test Date                         2013/1/26
Environmental
                                 24oC, 50% RH                    Test Mode                         Mode 1
Conditions
Tested by                        Moore Cheng                     Line                              L1




                    QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average
        Frequency                                                                                                      Remark
 NO.                 reading    reading     factor      result     result     limit      limit      margin   margin
          (MHz)                                                                                                       (Pass/Fail)
                      (dBuV)    (dBuV)      (dB)       (dBuV)     (dBuV)     (dBuV)    (dBuV)        (dB)      (dB)

  1       0.1689      38.67      21.40      9.87        48.54     31.27      65.01      55.01       -16.47   -23.74      Pass

  2       0.1995      34.70      18.88      9.87        44.57     28.75      63.63      53.63       -19.06   -24.88      Pass

  3       0.2530      29.50      17.72      9.88        39.38     27.60      61.65      51.66       -22.27   -24.06      Pass

  4       0.3620      21.52      12.05      9.88        31.40     21.93      58.68      48.68       -27.28   -26.75      Pass

  5       3.3787      15.95      13.80      9.99        25.94     23.79      56.00      46.00       -30.06   -22.21      Pass

  6      17.1556      20.29      11.22      10.32       30.61     21.54      60.00      50.00       -29.39   -28.46      Pass

 REMARKS: L1 = Line One (Live Line)




                                                            Page 14
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


  FCC ID: XPYSARAG350                          IC: 8595A-SARAG350                                Report No: T130724W03-D



                                               CCS Conduction Test

Model No.                        SARA-G310                       Test Date                         2013/1/26
Environmental
                                 24oC, 50% RH                    Test Mode                         Mode 1
Conditions
Tested by                        Moore Cheng                     Line                              L2




                    QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average
        Frequency                                                                                                      Remark
 NO.                 reading    reading     factor      result     result     limit      limit      margin   margin
          (MHz)                                                                                                       (Pass/Fail)
                      (dBuV)    (dBuV)      (dB)       (dBuV)     (dBuV)     (dBuV)    (dBuV)        (dB)      (dB)

  1       0.1740      38.99      23.49      9.63        48.62     33.12      64.76      54.77       -16.14   -21.65      Pass

  2       0.2020      35.81      22.07      9.64        45.45     31.71      63.52      53.53       -18.07   -21.82      Pass

  3       0.2300      31.84      19.54      9.64        41.48     29.18      62.45      52.45       -20.97   -23.27      Pass

  4       0.3500      23.61      14.38      9.65        33.26     24.03      58.96      48.96       -25.70   -24.93      Pass

  5       3.4060      19.17      10.87      9.78        28.95     20.65      56.00      46.00       -27.05   -25.35      Pass

  6      18.0620      20.52      11.05      10.23       30.75     21.28      60.00      50.00       -29.25   -28.72      Pass

 REMARKS: L2 = Line Two (Neutral Line)




                                                            Page 15
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D



7 RADIATED EMISSION MEASUREMENT
7.1. LIMITS OF RADIATED EMISSION MEASUREMENT
According to FCC Part 15.33 (b), for an unintentional radiator, including a digital device,
the spectrum shall be investigated from the lowest radio frequency signal generated or
used in the device, without going below the lowest frequency for which a radiated
emission limit is specified, up to the frequency shown in the following table:
Highest frequency generated or used in the
                                                Upper frequency of measurement range
device or on which the device operates or
                                                                  (MHz)
tunes (MHz)
                  Below 1.75                                        30
                   1.75-108                                        1000
                    108-500                                        2000
                   500-1000                                        5000
                                                5th harmonic of the highest frequency or
                 Above 1000
                                                       40GHz, whichever is lower
Below 1GHz (for digital device)
                                                                       dBuV/m (At 10m)
             FREQUENCY (MHz)
                                                            Class A                           Class B
                     30 ~ 230                                    40                                30
                   230 ~ 1000                                    47                                37
Limit tables for non-digital device:
Class A Radiated Emission limit at 10m (for others)
      Frequency                      Field Strength Limit                          Field Strength Limit
        (MHZ)                             (uV/m)Q.P.                                  (dBuV/m)Q.P.
         30 - 88                                  90                                            39
        88 - 216                                 150                                           43.5
       216 – 960                                 210                                           46.4
       Above 960                                 300                                           49.5
Class B Radiated Emission limit at 3m (for others)
     Frequency          Field Strength Limit                                       Field Strength Limit
       (MHZ)                 (uV/m)Q.P.                                               (dBuV/m)Q.P.
       30 - 88                   100                                                        40
        88 - 216                                 150                                           43.5
       216 – 960                                 200                                            46
       Above 960                                 500                                            54



                                                        Page 16
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D



Above 1GHz (for all device)
      Frequency                 Class A (dBuV/m) (At 10m)                      Class B (dBuV/m) (At 3m)
        (MHZ)                      Average                 Peak                Average                    Peak
      Above 1000                      49.5                  69.5                    54                      74
NOTE: (1) The lower limit shall apply at the transition frequencies.
      (2) Emission level (dBuV/m) = 20 log Emission level (uV/m).
      (3) The measurement above 1GHz is at close-in distances 3m,and determine the limit L2
          corresponding to the close-in distance d2 by applying the following relation: L2 = L1 (d1/d2),
          where L1 is the specified limit in microvolts per metre (uV/m) at the distance d1 (10m), L2 is the
          new limit for distance d2 (3m).
          So the new Class A limit above 1GHz at 3m is as following table:


                              Frequency                  Class A (dBuV/m) (At 3m)
                                (MHZ)                     Average                  Peak
                              Above 1000                       60                    80




                                                        Page 17
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D


7.2. TEST INSTRUMENTS
                                               Wugu 10M Chamber
Name of Equipment           Manufacturer                    Model                 Serial Number Calibration Due
 Spectrum Analyzer              Agilent                    E4446A                  MY48250297            10/04/2013
  EMI Test Receiver              R&S                        ESCI                      100961             09/02/2013
  EMI Test Receiver              R&S                        ESCI                      100962             09/02/2013
    Pre-Amplifier                 HP                       8447D                   2944A07754            06/05/2014
    Pre-Amplifier                 HP                       8447D                   2944A08150            06/05/2014
    Pre-Amplifier                EMC                    EMC012645                     980056             05/09/2014
    Pre-Amplifier               MITEQ             AMF-6F-260400-40-8P                 985646             08/06/2013
    Bilog Antenna              TESEQ                     CBL 6112D                     31674             10/01/2013
    Bilog Antenna              TESEQ                     CBL 6112D                     31675             10/01/2013
    Horn Antenna                EMCO                         3117                      55167             01/09/2014
    Horn Antenna                EMCO                         3116                      26370             01/07/2014
    Coaxial Cable          Huber+Suhner                    104PEA                  33948/4PEA            05/09/2014
    Coaxial Cable          Huber+Suhner                    104PEA                  33949/4PEA            05/09/2014
    Coaxial Cable          Huber+Suhner                      104                     330026/4            05/09/2014
    Coaxial Cable          Huber+Suhner                      104                     330029/4            05/09/2014
    Coaxial Cable          Huber+Suhner                      104                     329382/4            05/09/2014
    Coaxial Cable          Huber+Suhner                      104                     330028/4            05/09/2014
      Turn Table                 CCS                      CC-T-1F                        N/A                N.C.R
   Antenna Tower                 CCS                      CC-A-1F                        N/A                N.C.R
      Controller                 CCS                      CC-C-1F                        N/A                N.C.R
   Antenna Tower           Sunol Sciences                   TLT2                     031010-5               N.C.R.
      Controller           Sunol Sciences                 SC104V                     031010-1               N.C.R.
      Site NSA                   CCS                         N/A                         N/A              11/04/2013
     Site VSWR                   CCS                         N/A                         N/A             12/02/2013
      Test S/W                                              EZ-EMC (CCS-3A1RE)
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Request.




                                                        Page 18
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D




7.3. TEST PROCEDURES                             (please refer to measurement standard or CCS SOP PA-031)

The basic test procedure was in accordance with ANSI C63.4-2009 and ICES-003:
2004.
Frequency range 30MHz ~ 1GHz
1. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
    a 10 meter semi-anechoic chamber room. The table was rotated 360 degrees to
    determine the position.
2. The EUT was set 10 meters away form the interference-receiving antenna, which
    was mounted on the top of a variable-height antenna tower.
3. The height of antenna is varied from one meter to four meter above the ground to
    determine the maximum value of the field strength. Both horizontal and vertical
    polarizations of the antenna are set to make the measurement.
4. For each suspected emission, the EUT was arranged to its worst case and then
    the antenna was turned to heights for 1 meter to 4 meters and the turn table was
    turned form 0 degrees to 360 degrees to find the maximum reading.
5. The test-receiver system was set to quasi-peak detect function and specified
    bandwidth with maximum hold mode when the test frequency is below 1GHz.

NOTE: The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for
Quasi-peak detection (QP) at frequency below 1GHz.
Frequency range above 1GHz
1. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
    a 3 meter semi-anechoic chamber room. The table was rotated 360 degrees to
    determine the position.
2. The EUT was set 3 meters away form the directional antenna, which was pointed
    towards the source of the emission within the EUT. This could be done by either
    pointing the antenna at an angle towards the source of the emission, or by
    rotating the EUT, in both height and polarization, to maximize the measured
    emission.
3. The height of antenna can be varied from one meter to four meters, the height of
    adjustment depends on the EUT height and the antenna 3 dB beamwidth both, to
    detect the maximum value of the field strength. Both horizontal and vertical
    polarizations of the antenna are set to make the measurement.
4. For each suspected emission, the EUT was arranged to its worst case and then
    the antenna was turned to heights and the rotatable table was turned form 0
    degrees to 360 degrees to find the maximum reading.
5. The test-receiver system was set to peak and average detect function and
    specified bandwidth with maximum hold mode when the test frequency is above
    1GHz.
NOTE:
1. The resolution bandwidth is 1MHz and video bandwidth of test spectrum analyzer
    is 1 MHz for peak detection at above 1GHz. The resolution bandwidth is 1MHz
    and video bandwidth of test spectrum analyzer is 100Hz for average detection at
    frequency above 1 GHz.
2. For measurement of frequency above 1GHz, the EUT was set 3 meters away
    from the directional antenna.

                                                        Page 19
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                              Report No: T130724W03-D


7.4. TEST SETUP
Below 1GHz




                                         Test table &
                                         Turntable
                                                                                                 1m ~ 4m
                         Boundary of
                            EUT
                                                                         Coaxial
                                                                         Cable
  Power                                           0.8 m
  Cable


                                                        3 or 10 m
                                                                                                Ground Plane
            Filter                To Power
                                                                                             EMI
                                                                                           Receiver



Above 1GHz

                             3m                                                Boresight
                                                                               Antenna
                                                                                tower


                                                                               Horn
                                                                              antenna
   EUT


                                                                                Spectrum
                                                                                analyzer
                              4m


         Turntable
                     0 .8m          1m
                                              30cm
                                                                                   Pre-amp
                       ▲▲▲▲▲▲

  z     For the actual test configuration, please refer to the related item – Photographs of
      the Test Configuration.




                                                        Page 20
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D


7.5. DATA SAMPLE
Below 1GHz
                           Correction                                                              Degree
Frequency     Reading                       Result        Limit        Margin        Height
                            Factor                                                                               Remark
  (MHz)       (dBuV)                      (dBuV/m)      (dBuV/m)        (dB)          (cm)          (。)
                            (dB/m)

  xx.xx        16.49          9.86         26.35         30.00          -3.65        116.00       101.00           QP


Above 1GHz
 Frequency     Reading      Correction       Result         Limit        Margin         Height        Degree
                                                                                                                    Remark
   (MHz)       (dBuV)      Factor(dB/m)    (dBuV/m)       (dBuV/m)        (dB)           (cm)           (°)

  xx.xx         60.80         -14.59         46.21         74.00         -27.79          200           351           peak

  xx.xx         52.05         -13.17         38.88         54.00         -15.12          200           135           AVG

Frequency (MHz)                      = Emission frequency in MHz
Reading (dBuV)                       = Uncorrected Analyzer / Receiver reading
Correction Factor (dB/m)             = Antenna factor + Cable loss – Amplifier gain
Result (dBuV/m)                      = Reading (dBuV) + Corr. Factor (dB/m)
Limit (dBuV/m)                       = Limit stated in standard
Margin (dB)                          = Result (dBuV/m) – Limit (dBuV/m)
Q.P.                                 = Quasi-Peak




                                                        Page 21
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D


7.6. TEST RESULTS
Below 1000MHz

Model No.                      SARA-G310                     Test Mode                      Mode 1
Environmental
                               26oC, 60% RH                  Test Date                      2013/7/30
Conditions
Antenna Pole                   Vertical                      Antenna Distance               10m

Detector Function:             Quasi-peak.                   Tested by                      Moore Cheng

Standard                       FCC CLASS B W/ CISPR 22 CLASS B LIMIT




No.   Frequency       Reading       Correction      Result        Limit      Margin       Height       Degree      Remark
         (MHz)        (dBuV)      Factor(dB/m) (dBuV/m) (dBuV/m)               (dB)         (cm)         (°)
 1      31.9400        36.72          -9.64         27.08        30.00        -2.92         100          89           QP
 2      47.4600        45.90          -17.20        28.70        30.00        -1.30         100          358          QP
 3      59.1000        49.31          -19.50        29.81        30.00        -0.19         399           1           QP
 4      71.7100        47.77          -19.22        28.55        30.00        -1.45         214           0           QP
 5     167.7400        40.28          -14.95        25.33        30.00        -4.67         100          240          QP
 6     823.4600        32.55          -2.27         30.28        37.00        -6.72         214           0           QP
REMARKS:          1. The other emission levels were very low against the limit.
                  2. 30MHz to 1000MHz test is Applicable CISPR 22 standard.


                                                        Page 22
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                        IC: 8595A-SARAG350                            Report No: T130724W03-D


Below 1000MHz

Model No.                      SARA-G310                     Test Mode                      Mode 1
Environmental
                               26oC, 60% RH                  Test Date                      2013/7/30
Conditions
Antenna Pole                   Horizontal                    Antenna Distance               10m

Detector Function:             Quasi-peak.                   Tested by                      Moore Cheng

Standard                       FCC CLASS B W/ CISPR 22 CLASS B LIMIT




No.   Frequency       Reading       Correction      Result        Limit      Margin       Height       Degree      Remark
         (MHz)        (dBuV)      Factor(dB/m) (dBuV/m) (dBuV/m)               (dB)         (cm)         (°)
 1      40.6700        35.78          -14.42        21.36        30.00        -8.64         399           0           QP
 2      95.9600        36.25          -15.78        20.47        30.00        -9.53         400          114          QP
 3     167.7400        44.54          -15.52        29.02        30.00        -0.98         400          270          QP
 4     824.4300        34.13          -3.16         30.97        37.00        -6.03         100           1           QP
 5     877.7800        32.36          -2.52         29.84        37.00        -7.16         400          260          QP
 6     974.7800        31.78          -1.06         30.72        37.00        -6.28         399           0           QP
REMARKS:          1. The other emission levels were very low against the limit.
                  2. 30MHz to 1000MHz test is Applicable CISPR 22 standard.




                                                        Page 23
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


FCC ID: XPYSARAG350                      IC: 8595A-SARAG350                         Report No: T130724W03-D


Below 1000MHz

Model No.                     SARA-G310                   Test Mode                   Mode 2
Environmental
                              26oC, 60% RH                Test Date                   2013/7/30
Conditions
Antenna Pole                  Vertical                    Antenna Distance            10m

Detector Function:            Quasi-peak.                 Tested by                   Moore Cheng

Standard                      FCC CLASS B W/ CISPR 22 CLASS B LIMIT




 No.   Frequency     Reading      Correction     Result       Limit     Margin      Height     Degree      Remark
         (MHz)        (dBuV)     Factor(dB/m) (dBuV/m) (dBuV/m)          (dB)        (cm)         (°)
  1     39.7000       36.37          -7.78       28.59       30.00       -1.41       100          61         QP
  2     47.4600       47.06         -17.20       29.86       30.00       -0.14       100         356         QP
  3     59.1000       48.00         -19.50       28.50       30.00       -1.50       279          0          QP
  4     71.7100       47.67         -19.22       28.45       30.00       -1.55       100         331         QP
  5    167.7400       40.44         -14.95       25.49       30.00       -4.51       100         196         QP
  6    528.5800       29.15          -5.41       23.74       37.00      -13.26       100         304         QP
REMARKS:          1. The other emission levels were very low against the limit.
                  2. 30MHz to 1000MHz test is Applicable CISPR 22 standard.




                                                    Page 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Se
                                                                                                          rvices.


 FCC ID: XPYSARAG350                        IC: 8595A-SARAG350                            Report No: T130724W03-D


Below 1000MHz

Model No.                      SARA-G310                     Test Mode                      Mode 2
Environmental
                               26oC, 60% RH                  Test Date                      2013/7/30
Conditions
Antenna Pole                   Horizontal                    Antenna Distance               10m

Detector Function:             Quasi-peak.                   Tested by                      Moore Cheng

Standard                       FCC CLASS B W/ CISPR 22 CLASS B LIMIT




No.   Frequency       Reading       Correction      Result        Limit      Margin       Height       Degree      Remark
         (MHz)        (dBuV)      Factor(dB/m) (dBuV/m) (dBuV/m)               (dB)         (cm)         (°)
 1      31.9400        31.69          -9.39         22.30        30.00        -7.70         400          88           QP
 2      47.4600        38.40          -17.61        20.79        30.00        -9.21         400          169          QP
 3      95.9600        36.97          -15.78        21.19        30.00        -8.81         400          108          QP
 4     167.7400        44.58          -15.52        29.06        30.00        -0.94         400          237          QP
 5     792.4200        25.41          -3.41         22.00        37.00       -15.00         400          74           QP
 6     966.0500        24.52          -1.20         23.32        37.00       -13.68         100          331          QP
REMARKS:          1. The other emission levels were very low against the limit.
                  2. 30MHz to 1000MHz test is Applicable CISPR 22 standard.




                                                        Page 25
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D


Below 1000MHz

Model No.                      SARA-G310                     Test Mode                      Mode 3
Environmental
                               26oC, 60% RH                  Test Date                      2013/7/30
Conditions
Antenna Pole                   Vertical                      Antenna Distance               10m

Detector Function:             Quasi-peak.                   Tested by                      Moore Cheng

Standard                       FCC CLASS B W/ CISPR 22 CLASS B LIMIT




No.   Frequency       Reading       Correction      Result        Limit      Margin       Height       Degree      Remark
         (MHz)        (dBuV)      Factor(dB/m) (dBuV/m) (dBuV/m)               (dB)         (cm)         (°)
 1      31.9400        36.88          -9.64         27.24        30.00        -2.76         100          205          QP
 2      40.6700        37.24          -8.73         28.51        30.00        -1.49         100           1           QP
 3      47.4600        47.07          -17.20        29.87        30.00        -0.13         136          360          QP
 4      59.1000        47.70          -19.50        28.20        30.00        -1.80         300           0           QP
 5      71.7100        46.58          -19.22        27.36        30.00        -2.64         200           0           QP
 6     167.7400        42.00          -14.95        27.05        30.00        -2.95         100          275          QP
REMARKS:          1. The other emission levels were very low against the limit.
                  2. 30MHz to 1000MHz test is Applicable CISPR 22 standard.




                                                        Page 26
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                        IC: 8595A-SARAG350                            Report No: T130724W03-D


Below 1000MHz

Model No.                      SARA-G310                     Test Mode                      Mode 3
Environmental
                               26oC, 60% RH                  Test Date                      2013/7/30
Conditions
Antenna Pole                   Horizontal                    Antenna Distance               10m

Detector Function:             Quasi-peak.                   Tested by                      Moore Cheng

Standard                       FCC CLASS B W/ CISPR 22 CLASS B LIMIT




No.   Frequency       Reading       Correction      Result        Limit      Margin       Height       Degree      Remark
         (MHz)        (dBuV)      Factor(dB/m) (dBuV/m) (dBuV/m)               (dB)         (cm)         (°)
 1      31.9400        31.32          -9.39         21.93        30.00        -8.07         300          86           QP
 2      47.4600        38.06          -17.61        20.45        30.00        -9.55         400          169          QP
 3      89.1700        37.61          -17.04        20.57        30.00        -9.43         300          121          QP
 4     167.7400        44.50          -15.52        28.98        30.00        -1.02         400          280          QP
 5     925.3100        24.59          -1.84         22.75        37.00       -14.25         200          69           QP
 6     996.1200        23.76          -0.66         23.10        37.00       -13.90         400          205          QP
REMARKS:          1. The other emission levels were very low against the limit.
                  2. 30MHz to 1000MHz test is Applicable CISPR 22 standard.




                                                        Page 27
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D


Above 1000MHz

Model No.                      SARA-G310                     Test Mode                      Mode 1
Environmental
                               26oC, 60% RH                  Test Date                      2013/8/2
Conditions
Antenna Pole                   Vertical                      Antenna Distance               3m
Highest    frequency
                     1900MHz                                 Upper frequency                9500MHz
generated or used
Detector Function:             Average & Peak                Tested by                      Moore Cheng


       Frequency      Reading       Correction      Result        Limit       Margin       Height      Degree
 No.                                                                                                               Remark
         (MHz)         (dBuV)     Factor(dB/m) (dBuV/m)        (dBuV/m)        (dB)         (cm)          (°)

  1    2011.500        58.00          -16.79        41.21        74.00       -32.79         100          230         peak
  2    4927.000        58.58          -13.12        45.46        74.00       -28.54         100          25          peak
  3    6780.000        57.57          -10.32        47.25        74.00       -26.75         202          67          peak
  4    8497.000        57.00          -8.80         48.20        74.00       -25.80         100          303         peak
  5    10188.500       56.52          -6.13         50.39        74.00       -23.61         202          209         peak
  6    11871.500       55.43          -4.50         50.93        74.00       -23.07         105           0          peak
REMARKS:
1. The other emission levels were very low against the limit.
2. Margin (dB) = Result (dBuV/m) – Limit (dBuV/m)




                                                        Page 28
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                        IC: 8595A-SARAG350                            Report No: T130724W03-D




Model No.                      SARA-G310                     Test Mode                      Mode 1
Environmental
                               26oC, 60% RH                  Test Date                      2013/8/2
Conditions
Antenna Pole                   Horizontal                    Antenna Distance               3m
Highest    frequency
                     1900MHz                                 Upper frequency                9500MHz
generated or used
Detector Function:             Average & Peak                Tested by                      Moore Cheng


       Frequency      Reading       Correction      Result        Limit       Margin       Height      Degree
 No.                                                                                                               Remark
         (MHz)         (dBuV)     Factor(dB/m) (dBuV/m)        (dBuV/m)        (dB)         (cm)          (°)

  1    2139.000        57.66          -16.49        41.17        74.00       -32.83         202          360         peak
  2    4374.500        57.99          -13.51        44.48        74.00       -29.52         100          55          peak
  3    6414.500        58.30          -10.57        47.73        74.00       -26.27         100          55          peak
  4    8531.000        56.49          -8.74         47.75        74.00       -26.25         100          179         peak
  5    10154.500       56.29          -6.16         50.13        74.00       -23.87         100          145         peak
  6    11803.500       55.49          -4.51         50.98        74.00       -23.02         202           3          peak
REMARKS:
1. The other emission levels were very low against the limit.
2. Margin (dB) = Result (dBuV/m) – Limit (dBuV/m)




                                                        Page 29
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


FCC ID: XPYSARAG350                      IC: 8595A-SARAG350                         Report No: T130724W03-D


Above 1000MHz

Model No.                     SARA-G310                   Test Mode                   Mode 2
Environmental
                              26oC, 60% RH                Test Date                   2013/8/2
Conditions
Antenna Pole                  Vertical                    Antenna Distance            3m
Highest    frequency
                     1900MHz                              Upper frequency             9500MHz
generated or used
Detector Function:            Average & Peak              Tested by                   Moore Cheng


       Frequency     Reading       Correction    Result       Limit     Margin      Height      Degree
 No.                                                                                                       Remark
         (MHz)        (dBuV)     Factor(dB/m) (dBuV/m)     (dBuV/m)       (dB)       (cm)         (°)

  1    2283.500       57.56         -16.14       41.42       74.00      -32.58       202         306        peak
  2    4247.000       58.00         -13.76       44.24       74.00      -29.76       202         192        peak
  3    6057.500       58.70         -11.39       47.31       74.00      -26.69       100         167        peak
  4    7740.500       58.17          -9.26       48.91       74.00      -25.09       100          42        peak
  5    10103.500      56.07          -6.19       49.88       74.00      -24.12       100         275        peak
  6    11769.500      55.39          -4.51       50.88       74.00      -23.12       100         286        peak
REMARKS:
1. The other emission levels were very low against the limit.
2. Margin (dB) = Result (dBuV/m) – Limit (dBuV/m)




                                                    Page 30
This report shall not be reproduced except in full, without the written approval of Compliance Certification Se
                                                                                                          rvices.


 FCC ID: XPYSARAG350                        IC: 8595A-SARAG350                            Report No: T130724W03-D




Model No.                      SARA-G310                     Test Mode                      Mode 2
Environmental
                               26oC, 60% RH                  Test Date                      2013/8/2
Conditions
Antenna Pole                   Horizontal                    Antenna Distance               3m
Highest    frequency
                     1900MHz                                 Upper frequency                9500MHz
generated or used
Detector Function:             Average & Peak                Tested by                      Moore Cheng


       Frequency      Reading       Correction      Result        Limit       Margin       Height      Degree
 No.                                                                                                               Remark
         (MHz)         (dBuV)     Factor(dB/m) (dBuV/m)        (dBuV/m)        (dB)         (cm)          (°)

  1    2207.000        59.03          -16.33        42.70        74.00       -31.30         202          124         peak
  2    4374.500        58.46          -13.51        44.95        74.00       -29.05         187           0          peak
  3    6227.500        57.76          -10.99        46.77        74.00       -27.23         100          94          peak
  4    7766.000        58.26          -9.21         49.05        74.00       -24.95         202          62          peak
  5    10188.500       56.12          -6.13         49.99        74.00       -24.01         202          272         peak
  6    11752.500       55.20          -4.50         50.70        74.00       -23.30         100          354         peak
REMARKS:
1. The other emission levels were very low against the limit.
2. Margin (dB) = Result (dBuV/m) – Limit (dBuV/m)




                                                        Page 31
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                       IC: 8595A-SARAG350                             Report No: T130724W03-D


Above 1000MHz

Model No.                      SARA-G310                     Test Mode                      Mode 3
Environmental
                               26oC, 60% RH                  Test Date                      2013/7/30
Conditions
Antenna Pole                   Vertical                      Antenna Distance               3m
Highest    frequency
                     1900MHz                                 Upper frequency                9500MHz
generated or used
Detector Function:             Average & Peak                Tested by                      Moore Cheng


       Frequency      Reading       Correction      Result        Limit       Margin       Height      Degree
 No.                                                                                                               Remark
         (MHz)         (dBuV)     Factor(dB/m) (dBuV/m)        (dBuV/m)        (dB)         (cm)          (°)

  1    12509.000       56.20          -2.70         53.50        74.00       -20.50         100          357         peak
  2    12509.000       45.24          -2.70         42.54        54.00        -11.46        100          357         AVG
  3    14387.500       55.77          -2.76         53.01        74.00       -20.99         100          348         peak
  4    14387.500       44.91          -2.76         42.15        54.00        -11.85        100          348         AVG
  5    15033.500       57.05          -0.82         56.23        74.00       -17.77         100          82          peak
  6    15033.500       46.13          -0.82         45.31        54.00        -8.69         100          82          AVG
  7    15943.000       55.85          -0.07         55.78        74.00       -18.22         100          200         peak
  8    15943.000       44.98          -0.07         44.91        54.00        -9.09         100          200         AVG
  9    16759.000       54.92           0.84         55.76        74.00       -18.24         100          189         peak
 10    16759.000       43.99           0.84         44.83        54.00        -9.17         100          189         AVG
 11    17396.500       54.90           0.94         55.84        74.00       -18.16         100          230         peak
 12    17396.500       44.12           0.94         45.06        54.00        -8.94         100          230         AVG
REMARKS:
1. The other emission levels were very low against the limit.
2. Margin (dB) = Result (dBuV/m) – Limit (dBuV/m)




                                                        Page 32
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


 FCC ID: XPYSARAG350                        IC: 8595A-SARAG350                            Report No: T130724W03-D




Model No.                      SARA-G310                     Test Mode                      Mode 3
Environmental
                               26oC, 60% RH                  Test Date                      2013/7/30
Conditions
Antenna Pole                   Horizontal                    Antenna Distance               3m
Highest    frequency
                     1900MHz                                 Upper frequency                9500MHz
generated or used
Detector Function:             Average & Peak                Tested by                      Moore Cheng


       Frequency      Reading       Correction      Result        Limit       Margin       Height      Degree
 No.                                                                                                               Remark
         (MHz)         (dBuV)     Factor(dB/m) (dBuV/m)        (dBuV/m)        (dB)         (cm)          (°)

  1    12543.000       54.98          -2.72         52.26        74.00       -21.74         100          84          peak
  2    12543.000       44.26          -2.72         41.54        54.00       -12.46         100          84          AVG
  3    14226.000       55.54          -3.12         52.42        74.00       -21.58         100          360         peak
  4    14226.000       44.79          -3.12         41.67        54.00       -12.33         100          360         AVG
  5    15084.500       55.51          -0.74         54.77        74.00       -19.23         100          23          peak
  6    15084.500       44.63          -0.74         43.89        54.00        -10.11        100          23          AVG
  7    15756.000       55.20          -0.11         55.09        74.00       -18.91         100          268         peak
  8    15756.000       44.43          -0.11         44.32        54.00        -9.68         100          268         AVG
  9    16563.500       54.29           0.77         55.06        74.00       -18.94         100          23          peak
 10    16563.500       43.47           0.77         44.24        54.00        -9.76         100          23          AVG
 11    17396.500       54.36           0.94         55.30        74.00       -18.70         100          356         peak
 12    17396.500       43.53           0.94         44.47        54.00        -9.53         100          356         AVG
REMARKS:
1. The other emission levels were very low against the limit.
2. Margin (dB) = Result (dBuV/m) – Limit (dBuV/m)




                                                        Page 33
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Document Created: 2013-08-27 11:40:10
Document Modified: 2013-08-27 11:40:10

© 2024 FCC.report