Test Report part 22

FCC ID: XPY1EHQ37NN

Test Report

Download: PDF
FCCID_4473049

                            FCC C2PC Test Report (Part 22)
                                                           GSM, WCDMA, LTE


 Test Report no.:                  EMC_BO_002245 (v1.0)               Date of Report:                           07-Oct-2019

 Number of pages:                  21                                 Project support engineer:                 Frank Wittmann

 Test period:                      04.Sep – 18.Sep.2019



 Applicant:                        Molex CVS Bochum GmbH, Meesmannstraße 103, 44807 Bochum, Germany, Bernhard Bläcker

 Manufacturer:                     Molex CVS Bochum GmbH, Meesmannstraße 103, 44807 Bochum, Germany

 EUT identification:               Molex, RCP-1g

 FCC ID:                           XPY1EHQ37NN



 Testing Laboratory:               Molex CVS Lab, Molex CVS Bochum GmbH, Meesmannstr.103, 44807 Bochum, Germany
                                   Tel.:                             +49 234 51668-0
                                   e-mail:                           Product.Validation.Bochum@molex.com
                                   FCC Designation number            DE0017

                                   Laboratory manager:               Robert Müller


 Test result                       The EUT complies with the requirements made in the referred test documents.



 Approver:                         Jürgen Mitterer                           Technical Review:                        Frank Wittmann

 Title:                            Validation and Test                       Title:                                   Senior Test Engineer EMC
                                   Engineering Manager
 Signature:                                                                  Signature:




This test report may not be reproduced, except in full, without written permission of testing laboratory. The test result in this test report relates only
to the tested sample, which is mentioned in this test report. Molex CVS Bochum cannot be made responsible for any generalizations or conclusions
drawn from this test report. Modification of the tested sample is prohibited and leads to invalidity of this test report.




 Project support engineer:           Frank Wittmann                                                               FCC Test Report (XPY1EHQ37NN)
 Date of issue:                      07-Oct-2019                                                                            Template version 3.94
 Report No.:                         EMC_BO_002245 (v1.0)                                              Copyright © 2019 Molex. All rights reserved.
                                                                         1 (21)


Version History
        Report Number                       Date                       Comment
    EMC_BO_002245 (v1.0)                07-Oct-2019               First release version
               -                             -                              -
               -                             -                              -
               -                             -                              -




Project support engineer:   Frank Wittmann                                FCC Test Report (XPY1EHQ37NN)
Date of issue:              07-Oct-2019                                             Template version 3.94
Report No.:                 EMC_BO_002245 (v1.0)               Copyright © 2019 Molex. All rights reserved.
                                                      2 (21)


CONTENTS

VERSION HISTORY .................................................................................................................................. 2
1. SUMMARY FOR FCC PART 22 TEST REPORT ....................................................................................... 4
    1.1.     EUT AND ACCESSORY INFORMATION ................................................................................................ 4
    1.2.     TECHNICAL CHARACTERISTICS .......................................................................................................... 5
    1.3.     APPLIED STANDARDS .................................................................................................................... 6
    1.4.     MEASUREMENT UNCERTAINTIES ...................................................................................................... 6
    1.5.     SUMMARY OF TEST RESULTS ........................................................................................................... 7
2. TEST SETUPS .................................................................................................................................... 8
    2.1.     CONDUCTED TEST SETUP (SETUP 1) .................................................................................................. 8
    2.2.     CONDUCTED AC POWER LINE CONDUCTED EMISSIONS TEST SETUP (SETUP 2) .............................................. 8
    2.3.     RADIATED TEST SETUP (SETUP 3) ..................................................................................................... 8
4. RADIATED BAND EDGE COMPLIANCE ................................................................................................ 9
    4.1.     TEST REFERENCE AND LIMIT ............................................................................................................ 9
    4.2.     GSM850 TEST RESULTS .............................................................................................................. 10
    4.3.     WCDMA5 TEST RESULTS ............................................................................................................ 11
    4.4.     LTE5 TEST RESULTS .................................................................................................................... 13
5. SPURIOUS RADIATED EMISSIONS.................................................................................................... 14
    5.1.     TEST REFERENCE AND LIMIT .......................................................................................................... 14
    5.2.     GSM850 TEST RESULTS ............................................................................................................... 16
    5.3.     WCDMA5 TEST RESULTS ............................................................................................................. 17
    5.4.     LTE5 TEST RESULTS..................................................................................................................... 18
6. TEST EQUIPMENT ........................................................................................................................... 19
    6.1.     CONDUCTED MEASUREMENTS ....................................................................................................... 19
    6.2.     RADIATED MEASUREMENTS .......................................................................................................... 20




 Project support engineer:          Frank Wittmann                                                             FCC Test Report (XPY1EHQ37NN)
 Date of issue:                     07-Oct-2019                                                                          Template version 3.94
 Report No.:                        EMC_BO_002245 (v1.0)                                            Copyright © 2019 Molex. All rights reserved.
                                                                       3 (21)


1.          Summary for FCC Part 22 Test Report

 Date of receipt                            17-06-2019
 Testing completed                          18-09-2019
 The customer's contact person              Bernhard Bläcker
 Notes                                      none

1.1.        EUT and Accessory Information
The EUT is an Onboard Logic Unit (OLU) designed for automobiles with following features:
GSM, WCDMA, LTE, WLAN, Bluetooth, Bluetooth Low Energy.
The EUT is tested with maximum rated TX power.
Radiated measurements were done with dedicated antenna from the customer.

  Device Under Test (DUT)
           Product           Manufacturer          Type              SN          HW       MV       SW          ID
       Onboard Logic Unit      Molex              RCP-1g        PM81905800468    5373      -      12.0.1   BOC191094E
       Onboard Logic Unit      Molex              RCP-1g        PM81905800531    5373      -      12.0.1   BOC191095E

 Accessory Equipment
           Product           Manufacturer         Type               SN           HW      MV       SW          ID
        System Cable             Molex              -                 -            -       -        -      BOC180655E
        System Cable             Molex              -                 -            -       -        -      BOC180376E
        RF Cable (4x)            Molex              -                 -            -       -        -      BOC180657E
        RF Cable (4x)            Molex              -                 -            -       -        -      BOC180377E
     MBN Cellular Antenna         MBN         A231 905 08 02          -            -       -        -      BOC191041E
        GNSS Antenna          Hirschmann       GLONASS 9 M            -            -       -        -      BOC190623E
      1000Base-T1 Cable          Molex              -                 -            -       -        -      BOC181025E
          USB Cable              Molex              -                 -            -       -        -      BOC180850E
          USB Cable              Molex              -                 -            -       -        -      BOC180847E




 Project support engineer:   Frank Wittmann                                                FCC Test Report (XPY1EHQ37NN)
 Date of issue:              07-Oct-2019                                                             Template version 3.94
 Report No.:                 EMC_BO_002245 (v1.0)                               Copyright © 2019 Molex. All rights reserved.
                                                           4 (21)


1.2.       Technical Characteristics
  Operating Voltage                     Unom = +12 V DC
  Temperature Range                     Tmin = -40 °C                             Tmax = +80 °C
  Operating Voltage Range               UBmin = +9.0 V                            UBmax = +16.0 V
  Type of Equipment                     Portable
  CELLULAR Module                       uBlox, Toby L4006
  GSM                                   E-GSM900, Power Class 4/E2 (33/27dBm)
                                        DCS1800, Power Class 1/E2 (30/27dBm)
  UTRA                                  WCDMA-HSPA+
                                        FDD Band 1/8, Power Class 3 (24dBm)
  E-UTRA                                LTE-A Rel10 (MIMO 2x2, 1x TX/RX +1x RX only, Cat6)
                                        FDD Bands 1/3/7/8/20 +TDD Band 38, Power Class 3 (23dBm)
                                        LTE-CA (RX) 3+20/7+20/3+3/3+7, No LTE-CA (TX)
  BT-WLAN Module                        muRata, LBEE6ZZ1PY
  BT                                    Bluetooth 5 Dual Mode (2.4GHz, SISO, 1x TXRX)
                                        BDR (1 Mbit/s), EDR (2 Mbit/s, 3 Mbit/s), BLE (1 Mbit/s, 2 Mbit/s)
                                        802.15: BT Classic: 2402-2480 MHz, 79, OFDM (1 MHz), AFH, (0<P<10dbm)
                                        802.15: BT Low Energy: 2402-2480 MHz, 40, OFDM (1 MHz), AFH, (0<P<10dbm)
  WLAN                                  2.4 GHz, SISO, 1x TXRX, 38.4 MHz reference clock
                                        802.11b: 2412-2472 MHz, 1, 2, 5.5, 11 Mbps, DSSS/CCK, (>10dbm)
                                        802.11g: 2412-2472 MHz, 6, 9, 12, 18, 24, 36, 48, 54 Mbps, OFDM, (>10dbm)
                                        802.11n: 2412-2472 MHz, MCS0-7, OFDM (20 MHz), (>10dbm)
  WLAN (U-NII-3)                        5.8 GHz, SISO, 1x TXRX, 38.4 MHz reference clock, no DFS
  (U-NII-1, 2A and 2C deactivated)      802.11a: 5725-5825 MHz, 6, 9, 12, 18, 24, 36, 48, 54 Mbps, OFDM, (>10dbm)
                                        802.11n: 5725-5825 MHz, MCS0-7, OFDM (40 MHz), (>10dbm)
                                        802.11ac: 5725-5825 MHz, MCS0-9, OFDM (80 MHz), (>10dbm)
  GNSS Module                           uBlox, NEO-M8L-03A
  (Galileo and Beidou deactivated)
  GPS                                   GPS, L1C/A (1575.42MHz)
  GLONASS                               GLONASS, L1OF (1602MHz)
  Audio Interface                       1x Mic-Input/Output
  (no audio call supported)             1x Line-Out
  Other CAR Interfaces                  3x CAN (up to 500 kbit/s)
                                        1x LIN
                                        1x USB
                                        1x 1000Base-T1 (1 Gbit/s)
                                        4x HS-Switches (12 V)
                                        Digital I/O’s




 Project support engineer:    Frank Wittmann                                                 FCC Test Report (XPY1EHQ37NN)
 Date of issue:               07-Oct-2019                                                              Template version 3.94
 Report No.:                  EMC_BO_002245 (v1.0)                                Copyright © 2019 Molex. All rights reserved.
                                                            5 (21)


1.3.        Applied Standards
           Standard / Rule Part                          Version                                Year
         CFR 47, FCC Part 2 and 22                          -                      as of current date of e-CFR data
               ANSI C63.26                                  -                                 Dec-2015




Deviations or clarifications to these standards are noted in the related test result under “Test reference and limit”.

1.4.        Measurement Uncertainties
               Parameter                      Measurement Uncertainty                  Maximum Uncertainty
             Radio Frequency                         ±3.6 x 10-7                               ±1 x 10-5
        Total RF Power, conducted                    ±0.79 dB                                  ± 1.5 dB
       RF Power density, conducted                   ±0.79 dB                                  ± 3.0 dB
       Spurious emissions, conducted                 ±1.67 dB                                  ± 3.0 dB
          All emissions, radiated                    ±5.38 dB                                  ± 6.0 dB
               Temperature                            ±1.0 °C                                   ± 3 °C
                 Humidity                                ±2.0 %                                ± 5.0 %
These uncertainties represent an expanded uncertainty expressed approximately at the 95% confidence level using a
coverage factor of k=2




 Project support engineer:        Frank Wittmann                                             FCC Test Report (XPY1EHQ37NN)
 Date of issue:                   07-Oct-2019                                                          Template version 3.94
 Report No.:                      EMC_BO_002245 (v1.0)                            Copyright © 2019 Molex. All rights reserved.
                                                                6 (21)


1.5.      Summary of Test Results
GSM 850
       Section in CFR 47                                          Name of the test                           Result
   §22.913(a)(5), §2.1046(a)                                 Conducted RF output power                        NP
   §22.913(a)(5), §2.1046(a)                                  Radiated RF output power                        NP
             N/A                                             Peak-to-average power ratio                      NP
   §22.917(a)(b), §2.1049(h)                               99 % / 26 dB occupied bandwidth                    NP
    §22.917(a)(b), §2.1053                                      Band edge compliance                        PASSED
    §22.917(a)(b), §2.1051                             Spurious emissions at antenna terminals                NP
    §22.917(a)(b), §2.1053                                   Spurious radiated emissions                    PASSED
    §22.355, §2.1055(a)(1)                            Frequency stability, temperature variation              NP
     §22.355, §2.1055(d)                                 Frequency stability, voltage variation               NP

WCDMA Band 5
       Section in CFR 47                                          Name of the test                           Result
   §22.913(a)(5), §2.1046(a)                                 Conducted RF output power                        NP
   §22.913(a)(5), §2.1046(a)                                  Radiated RF output power                        NP
             N/A                                             Peak-to-average power ratio                      NP
   §22.917(a)(b), §2.1049(h)                               99 % / 26 dB occupied bandwidth                    NP
    §22.917(a)(b), §2.1053                                      Band edge compliance                        PASSED
    §22.917(a)(b), §2.1051                             Spurious emissions at antenna terminals                NP
    §22.917(a)(b), §2.1053                                   Spurious radiated emissions                    PASSED
    §22.355, §2.1055(a)(1)                            Frequency stability, temperature variation              NP
     §22.355, §2.1055(d)                                 Frequency stability, voltage variation               NP

LTE Band 5
       Section in CFR 47                                          Name of the test                           Result
   §22.913(a)(5), §2.1046(a)                                 Conducted RF output power                        NP
   §22.913(a)(5), §2.1046(a)                                  Radiated RF output power                        NP
             N/A                                             Peak-to-average power ratio                      NP
   §22.917(a)(b), §2.1049(h)                               99 % / 26 dB occupied bandwidth                    NP
    §22.917(a)(b), §2.1053                                      Band edge compliance                        PASSED
    §22.917(a)(b), §2.1051                             Spurious emissions at antenna terminals                NP
    §22.917(a)(b), §2.1053                                   Spurious radiated emissions                    PASSED
    §22.355, §2.1055(a)(1)                            Frequency stability, temperature variation              NP
     §22.355, §2.1055(d)                                 Frequency stability, voltage variation               NP

PASSED:       The EUT complies with the essential requirements in the standard.
FAILED:       The EUT does not comply with the essential requirements in the standard.
NP:           The test was not performed.
NA:           The test was not applicable




 Project support engineer:     Frank Wittmann                                              FCC Test Report (XPY1EHQ37NN)
 Date of issue:                07-Oct-2019                                                           Template version 3.94
 Report No.:                   EMC_BO_002245 (v1.0)                             Copyright © 2019 Molex. All rights reserved.
                                                       7 (21)


2.        Test setups
2.1.      Conducted test setup (Setup 1)


                          Radio
                        simulator

                                         Directional               10dB                 EUT
                                          Coupler               attenuator
 Spectrum                 10dB
 analyser              attenuator




2.2.      Conducted AC power line conducted emissions test setup (Setup 2)



        Receiver                    Attenuator                  LISN                    EUT




2.3.      Radiated test setup (Setup 3)




           Communication
           Tester


                                       EUT
         Mast & turn table
         controller                                                          Test
                                                                             Receiver




 Project support engineer:   Frank Wittmann                                               FCC Test Report (XPY1EHQ37NN)
 Date of issue:              07-Oct-2019                                                            Template version 3.94
 Report No.:                 EMC_BO_002245 (v1.0)                              Copyright © 2019 Molex. All rights reserved.
                                                       8 (21)


4.         Radiated Band edge compliance

 DUT with ID number                                       BOC191095E
 Accessories with DUT numbers                             BOC180655E, BOC180657E, BOC190623E, BOC180850E,
                                                          BOC181025E
 Operation Voltage [V] / [Hz]                             13.2 / DC
 Test Setup                                               Setup 3
 Result                                                   PASSED
 Remarks                                                  None
 Temp [°C] / Humidity [%RH]                               22.9 / 43.5
 Date of measurements                                     09.Sep.2019 – 18.Sep.2019
 Test Engineer                                            Robert Müller
 Test system SW version                                   1.7.1

4.1.       Test reference and limit
The measurement is made according to FCC rules parts 22 and ANSI C63.26 section 5.7.

Limits for band edge compliance measurements
       Frequency Bands                  Frequency range [MHz]             FCC Limit [dBm]
         GSM 850                        Below 824 & Above 849                   -13
       WCDMA Band 5                     Below 824 & Above 849                   -13
        LTE Band 5                      Below 824 & Above 849                   -13




 Project support engineer:      Frank Wittmann                                            FCC Test Report (XPY1EHQ37NN)
 Date of issue:                 07-Oct-2019                                                         Template version 3.94
 Report No.:                    EMC_BO_002245 (v1.0)                           Copyright © 2019 Molex. All rights reserved.
                                                          9 (21)


4.2.           GSM850 Test results

       Operation Mode              Channel / fC [MHz]          Level [dBm]           Margin [dBm]             Limit [dBm]           Result
               GSM                     128 / 824.2               -21.77                   8.77                     -13              PASSED
               GSM                     251 / 848.8               -22.58                   9.58                     -13              PASSED


GSM, 824.2 MHz, RBW = 3kHz                                            GSM, 848.8 MHz, RBW = 3kHz
Marker:         823.997996 MHz           -21.77 dBm                   Marker:        849.002004 MHz           -22.58 dBm

 Level [dBm]                                                           Level [dBm]
 40                                                                    40




 20                                                                    20




  0                                                                       0




-20                                                                   -20




-40                                                                   -40




-60                                                                   -60
      823M        823.5M              824M            824.5M   825M           848M     848.5M              849M            849.5M     850M
                            Frequency [Hz]                                                       Frequency [Hz]




 Project support engineer:           Frank Wittmann                                                         FCC Test Report (XPY1EHQ37NN)
 Date of issue:                      07-Oct-2019                                                                      Template version 3.94
 Report No.:                         EMC_BO_002245 (v1.0)                                        Copyright © 2019 Molex. All rights reserved.
                                                                  10 (21)


4.3.           WCDMA5 Test results

       Operation Mode              Channel / fC [MHz]         Level [dBm]           Margin [dBm]             Limit [dBm]           Result
       FDD, RMC (R99)                  4132 / 826.4             -33.20                  20.20                     -13              PASSED
       FDD, RMC (R99)                  4233 / 846.6             -29.19                  16.19                     -13              PASSED
      FDD, HSDPA (R05)                 4132 / 826.4             -32.68                  19.68                     -13              PASSED
      FDD, HSDPA (R05)                 4233 / 846.6             -29.54                  16.54                     -13              PASSED
       FDD, HSPA (R06)                 4132 / 826.4             -32.68                  19.68                     -13              PASSED
       FDD, HSPA (R06)                 4233 / 846.6             -29.91                  16.91                     -13              PASSED



FDD, RMC (R99), 826.4MHz, RBW = 50kHz                                FDD, RMC (R99), 846.6MHz, RBW = 50kHz
Marker:         824.001002 MHz           -33.2 dBm                   Marker:        849.001002 MHz           -29.19 dBm

 Level [dBm]                                                          Level [dBm]
 40                                                                   40




 20                                                                   20




  0                                                                      0




-20                                                                  -20




-40                                                                  -40




-60                                                                  -60
      823M        823.5M              824M           824.5M   825M           848M     848.5M              849M            849.5M     850M
                            Frequency [Hz]                                                      Frequency [Hz]




 Project support engineer:           Frank Wittmann                                                       FCC Test Report (XPY1EHQ37NN)
 Date of issue:                      07-Oct-2019                                                                    Template version 3.94
 Report No.:                         EMC_BO_002245 (v1.0)                                      Copyright © 2019 Molex. All rights reserved.
                                                                 11 (21)


FDD, HSDPA (R05), 826.4MHz, RBW = 50kHz                              FDD, HSDPA (R05), 846.6MHz, RBW = 50kHz
Marker:        823.992986 MHz           -32.68 dBm                   Marker:        849.001002 MHz           -29.54 dBm

 Level [dBm]                                                          Level [dBm]
 40                                                                   40




 20                                                                   20




  0                                                                    0




-20                                                                  -20




-40                                                                  -40




-60                                                                  -60
      823M       823.5M              824M            824.5M   825M         848M       848.5M              849M            849.5M   850M
                           Frequency [Hz]                                                       Frequency [Hz]




FDD, HSPA (R06), 826.4MHz, RBW = 50kHz                               FDD, HSPA (R06), 846.6MHz, RBW = 50kHz
Marker:        823.998998 MHz           -32.68 dBm                   Marker:        849.007014 MHz           -29.91 dBm

 Level [dBm]                                                          Level [dBm]
 40                                                                   40




 20                                                                   20




  0                                                                    0




-20                                                                  -20




-40                                                                  -40




-60                                                                  -60
      823M       823.5M              824M            824.5M   825M         848M       848.5M              849M            849.5M   850M
                           Frequency [Hz]                                                       Frequency [Hz]




 Project support engineer:          Frank Wittmann                                                        FCC Test Report (XPY1EHQ37NN)
 Date of issue:                     07-Oct-2019                                                                     Template version 3.94
 Report No.:                        EMC_BO_002245 (v1.0)                                       Copyright © 2019 Molex. All rights reserved.
                                                                 12 (21)


4.4.           LTE5 Test results

                                                                                                                Margin
               Operation Mode                         Channel / fC [MHz]          Level [dBm]                                Limit [dBm]        Result
                                                                                                                [dBm]
       FDD, CBW 1.4MHz, QPSK, 6RB                       20407 / 824.7                 -27.08                    14.08                 -13       PASSED
       FDD, CBW 1.4MHz, QPSK, 6RB                       20643 / 848.3                 -25.82                    12.82                 -13       PASSED
       FDD, CBW 1.4MHz, 16QAM, 6RB                      20407 / 824.7                 -27.12                    14.12                 -13       PASSED
       FDD, CBW 1.4MHz, 16QAM, 6RB                      20643 / 848.3                 -26.72                    13.72                 -13       PASSED


824.7 MHz, QPSK, 6RB, RMS, RBW = 20kHz                                     848.3 MHz, QPSK, 6RB, RMS, RBW = 20kHz
Marker:         824.002004 MHz           -27.08 dBm                         Marker:            849.002004 MHz            -25.82 dBm

 Level [dBm]                                                                 Level [dBm]
 40                                                                         40




 20                                                                         20




  0                                                                           0




-20                                                                        -20




-40                                                                        -40




-60                                                                        -60
      823M        823.5M              824M             824.5M       825M          848M           848.5M              849M              849.5M     850M
                            Frequency [Hz]                                                                 Frequency [Hz]




824.7 MHz, 16QAM, 6RB, RMS, RBW = 20kHz                                     848.3 MHz, 16QAM, 6RB, RMS, RBW = 20kHz
Marker:         824.002004 MHz           -27.12 dBm                         Marker:            849.002004 MHz            -26.72 dBm

 Level [dBm]                                                                 Level [dBm]
 40                                                                         40




 20                                                                         20




  0                                                                           0




-20                                                                        -20




-40                                                                        -40




-60                                                                        -60
      823M        823.5M              824M             824.5M       825M          848M           848.5M              849M              849.5M     850M
                            Frequency [Hz]                                                                 Frequency [Hz]




 Project support engineer:           Frank Wittmann                                                                  FCC Test Report (XPY1EHQ37NN)
 Date of issue:                      07-Oct-2019                                                                               Template version 3.94
 Report No.:                         EMC_BO_002245 (v1.0)                                                 Copyright © 2019 Molex. All rights reserved.
                                                                        13 (21)


5.        Spurious radiated emissions

 DUT with ID number                     BOC191095E
 Accessories with DUT numbers           BOC180655E, BOC180657E, BOC190623E, BOC180850E, BOC181025E
 Operation Voltage [V] / [Hz]           13.2 / DC
 Test Setup                             Setup 3
 Result                                 PASSED
 Remarks                                None
 Temp [°C] / Humidity [%RH]             22.9 / 43.5
 Date of measurements                   04.Sep.2019 – 11.Sep.2019
 Test Engineer                          Robert Müller
 Test system SW version                 1.7.1

5.1.      Test reference and limit
The measurement is made according to FCC rules parts 22 and ANSI C63.26, section 5.5, as follows:

Below 1GHz:
The Preliminary Measurement and the Final Measurement is performed in 3m distance by rotating the turntable of 360
degrees.
The Preliminary Measurement is performed with floor absorbers on the floor and measuring antenna at fixed height
using 2-axis EUT position system.
The Final Measurement is performed if the Preliminary Measurement results are closer than 20 dB to the permissible
limit.
The Final Measurement is performed without floor absorbers and antenna height between 1m and 4m.

Between 1-18GHz:
The Preliminary Measurement and the Final Measurement is performed in 3m distance by rotating the turntable of 360
degrees at fixed height.
The Preliminary Measurement and the Final Measurement is performed with absorbers on the floor and measuring
antenna at fixed height using 2-axis EUT position system.
The Final Measurement is performed, if the Preliminary Measurement results are closer than 20 dB to the permissible
limit.

Above 18GHz:
The Preliminary Measurement and the Final Measurement is performed in 1.5m distance by rotating the turntable of
360 degrees at fixed height.
The Preliminary Measurement and the Final Measurement is performed with absorbers on the floor and measuring
antenna at fixed height using 2-axis EUT position system.
The Final Measurement is performed, if the Preliminary Measurement results are closer than 20 dB to the permissible
limit.

General:
The emissions less than 20 dB below the permissible value are reported. The measurement results are obtained by using
the direct field strength method and pre-test site path loss characterization.
ERP (dBm) = URX (dBμV) – 107 + ACF (dB) + GCF (dB)
EIRP (dBm) = ERP (dBm) + 2.15




 Project support engineer:   Frank Wittmann                                              FCC Test Report (XPY1EHQ37NN)
 Date of issue:              07-Oct-2019                                                           Template version 3.94
 Report No.:                 EMC_BO_002245 (v1.0)                             Copyright © 2019 Molex. All rights reserved.
                                                       14 (21)


URX = is the receiver reading
ACF = is the signal path correction factor including cable loss and preamplifier gain
GCF = is the pre-test site path loss characterization factor including site path loss and antenna gain.



Limits for spurious radiated emissions measurements
   Frequency Band                          Frequency range [MHz]                                 FCC Limit [dBm]
      GSM 850                                                                                          -13
      WCDMA 5                                     30 – 8000                                            -13
        LTE 5                                                                                          -13




 Project support engineer:    Frank Wittmann                                                  FCC Test Report (XPY1EHQ37NN)
 Date of issue:               07-Oct-2019                                                               Template version 3.94
 Report No.:                  EMC_BO_002245 (v1.0)                                 Copyright © 2019 Molex. All rights reserved.
                                                          15 (21)


5.2.           GSM850 test results

GSM, 824.2MHz, PK detector, RBW/VBW = 5MHz
       Level [dBm]
        0


 -10


 -20


 -30


 -40

                                                                                                          x
 -50


 -60                                                                                                                           x


 -70


 -80
            30M             60M          100M          200M              400M                1G               2G          3G                8.5G
                                                           Frequency [Hz]



GSM, 824.2MHz, PK detector, RBW/VBW=1/3MHz
 Frequency           Pol.         Height        Azimuth         Elevation       Correction         ERP              Limit          Result
   [MHz]                           [cm]          (deg)            (deg)            (dB)           [dBm]            (dBm)
  1673.14            HOR           170           132                20              -107.9        -47.9             -13            PASSED
  3350.20            HOR           170            51                 6              -113.7        -60.3             -13            PASSED
        -

No final measurement with RMS detector and 1/3MHz RBW/VBW done, due to more than 20dB margin to the limit.




 Project support engineer:                 Frank Wittmann                                                       FCC Test Report (XPY1EHQ37NN)
 Date of issue:                            07-Oct-2019                                                                    Template version 3.94
 Report No.:                               EMC_BO_002245 (v1.0)                                      Copyright © 2019 Molex. All rights reserved.
                                                                          16 (21)


5.3.           WCDMA5 test results

FDD, RMC, 836.6MHz, PK detector, RBW/VBW = 5MHz
       Level [dBm]
        0


 -10


 -20


 -30


 -40


 -50


 -60


 -70


 -80
            30M             60M       100M           200M              400M                1G           2G       3G             8.5G
                                                         Frequency [Hz]



FDD, RMC, 836.6MHz, PK detector, RBW/VBW=1/3MHz
 Frequency           Pol.         Height       Azimuth         Elevation      Correction         ERP          Limit        Result
   [MHz]                           [cm]         (deg)            (deg)           (dB)           [dBm]        (dBm)
        -

No final measurement with RMS detector and 1/3MHz RBW/VBW done, due to more than 20dB margin to the limit.




 Project support engineer:                 Frank Wittmann                                                    FCC Test Report (XPY1EHQ37NN)
 Date of issue:                            07-Oct-2019                                                                 Template version 3.94
 Report No.:                               EMC_BO_002245 (v1.0)                                   Copyright © 2019 Molex. All rights reserved.
                                                                         17 (21)


5.4.           LTE5 test results

FDD, CBW 1.4MHz, QPSK, 1 RB mid, 836.5MHz, PK detector, RBW/VBW = 5MHz
       Level [dBm]
        0


 -10


 -20


 -30


 -40


 -50

                                                                                                      x
 -60


 -70


 -80
            30M             60M          100M             200M              400M            1G            2G     3G             8.5G
                                                              Frequency [Hz]



FDD, CBW 1.4MHz, QPSK, 1 RB mid, 836.5MHz, PK detector, RBW/VBW=1/3MHz
 Frequency           Pol.         Height        Azimuth     Elevation       Correction    Level    Margin         Limit        Result
   [MHz]                           [cm]          (deg)        (deg)            (dB)      [dBm]     (dBm)         (dBm)
  1660.92            VER           170            51             0             -108.7    -56.4                     -13         PASSED
  1667.04            HOR           170           360             0             -108.8    -56.6                     -13         PASSED
  1672.54            VER           170            98             0             -108.7    -55.9                     -13         PASSED
  1678.75            VER           170           338            90             -108.3    -56.0                     -13         PASSED
        -

No final measurement with RMS detector and 1/3MHz RBW/VBW done, due to more than 20dB margin to the limit.




 Project support engineer:                 Frank Wittmann                                                    FCC Test Report (XPY1EHQ37NN)
 Date of issue:                            07-Oct-2019                                                                 Template version 3.94
 Report No.:                               EMC_BO_002245 (v1.0)                                   Copyright © 2019 Molex. All rights reserved.
                                                                              18 (21)


6.         Test Equipment
6.1.       Conducted measurements
                                                                                                 Next     Calibration
     Equipment     Manufacturer       Type      SERIAL-NO.       Actual Calibration
                                                                                              Calibration   Service
     Signal     ROHDE &
                                     SMP02     828269/008           09.08.2017                09.08.2020     DAkkS
  Generator     SCHWARZ
  BT-/W-Lan-  Hewlett Packard
                                    N4010A     MY46320388           17.08.2017                17.08.2020     DAkkS
   Testsetup     - Agilent
     Radio
                ROHDE &
Communication                       CMU 200      101138             22.05.2018                22.05.2020     DAkkS
                SCHWARZ
     Tester
    Climatic
                  Vötsch             VT4002     521/85094           09.10.2018                09.10.2019     DAkkS
   Chamber
   EMI Test     ROHDE &
                                     ESU26       100077             20.05.2019                20.05.2020     DAkkS
   Receiver     SCHWARZ
              Hewlett Packard
 Power Supply                        E3632A    MY40011318           23.05.2018                23.05.2020     DAkkS
                 - Agilent
                                    EMPower
  Powermeter            ETS                      7202040            18.01.2019                18.01.2022     DAkkS
                                    7002-006
 Vector Signal       ROHDE &
                                   SMBV100A      263158             16.05.2019                16.05.2020     DAkkS
  Generator          SCHWARZ
  Wideband
                     ROHDE &
    Radio                           CMW500       101674             22.05.2019                22.05.2020     DAkkS
                     SCHWARZ
 Comm.Tester




 Project support engineer:    Frank Wittmann                                          FCC Test Report (XPY1EHQ37NN)
 Date of issue:               07-Oct-2019                                                       Template version 3.94
 Report No.:                  EMC_BO_002245 (v1.0)                         Copyright © 2019 Molex. All rights reserved.
                                                       19 (21)


6.2.       Radiated measurements
                                                                              Actual           Next           Calibration
       Equipment         Manufacturer           Type          SERIAL-NO.
                                                                            Calibration     Calibration         Service
                         Schwarzbeck
        Antenna                              FMZB_1519         1519-056     14.07.2017      14.07.2020          DAkkS
                        Mess-Elektronik
                           ROHDE &
  EMI Test Receiver                            ESIB26         827769/010    23.05.2019      23.05.2020          DAkkS
                          SCHWARZ
                           ROHDE &
  Signal Generator                             SMP02          828269/008    09.08.2017      09.08.2020          DAkkS
                          SCHWARZ
                           ROHDE &
  Signal Generator                             SML01            100652      06.04.2018      06.04.2021          DAkkS
                          SCHWARZ
                       Hewlett Packard -
    Power Supply                               E3632A         KR75303301    17.05.2018      17.05.2020          DAkkS
                            Agilent
      Radio
                             ROHDE &
   Communication                              CMU 200           101138      22.05.2018      22.05.2020          DAkkS
                             SCHWARZ
      Tester
                              Wandel &
   Field Analyzer                              EMR20             P-0030     23.11.2017      23.11.2020          DAkkS
                             Goltermann
                              ROHDE &
        Antenna                                 HL025         359012/006         -                -              n.a.
                              SCHWARZ
                              ROHDE &
  EMI Test Receiver                            ESU26            100077      20.05.2019      20.05.2020          DAkkS
                              SCHWARZ
  Temp. / Humidity
                                Lufft          Opus 10           13262      11.01.2017      11.01.2020          DAkkS
      Logger
                           ROHDE &
        Antenna                                 HL562           100191      26.10.2018      26.10.2021          DAkkS
                          SCHWARZ
                           ROHDE &           HK-116: 20-
        Antenna                                              825177/0017    21.07.2017      21.07.2020          DAkkS
                          SCHWARZ             300MHz
                           ROHDE &           HK-116: 20-
        Antenna                                                 100401      21.07.2017      21.07.2020          DAkkS
                          SCHWARZ             300MHz
                           ROHDE &
        Antenna                                 HL223         832369/006    26.04.2019      26.04.2022          DAkkS
                          SCHWARZ
        Antenna          Schwarzbeck         UBA 9116          9116-396     28.07.2017      28.07.2020          DAkkS
        Antenna             Emco               3115            9810-5588    24.04.2018      24.04.2021          DAkkS
        Antenna          Schwarzbeck        BBHA-9120-D          01617      09.04.2019      09.04.2022          DAkkS
                           ROHDE &
        Antenna                                 HL223           100731      15.12.2016      15.12.2019          DAkkS
                          SCHWARZ
  H-Field Probe 100    Narda Safety Test
                                                Probe           M-0823      07.12.2017      07.12.2020          DAkkS
         cm²           Solutions GmbH
                       Narda Safety Test
 H-field Probe 3cm2                          2300/90.20          C-0150     23.04.2018      23.04.2021          DAkkS
                       Solutions GmbH
                         Schwarzbeck
        Antenna                              VAMP 9243         9243-486     23.05.2018      23.05.2021          DAkkS
                       Mess-Elektronik
   Exposure Level      Narda Safety Test
                                               ELT-400           N-0385     07.12.2017      07.12.2020          DAkkS
        Tester         Solutions GmbH
      Antenna               Emco               3160-09               1232   07.08.2017      07.08.2020          DAkkS
  Isotropic Electric      Wandel &
                                               Type 8           M-0082      23.11.2017      23.11.2020          DAkkS
     Field Probe         Goltermann
                           ROHDE &
  Signal Generator                            SMB100A           181275      08.07.2019      08.07.2020          DAkkS
                          SCHWARZ
                           ROHDE &
  EMI Test Receiver                            ESW44            101733      19.08.2019      19.08.2020          DAkkS
                          SCHWARZ
   Vector Signal           ROHDE &
                                              SMBV100A          263158      16.05.2019      16.05.2020          DAkkS
    Generator             SCHWARZ
  Wideband Radio           ROHDE &
                                              CMW500            101674      22.05.2019      22.05.2020          DAkkS
   Comm.Tester            SCHWARZ



 Project support engineer:       Frank Wittmann                                           FCC Test Report (XPY1EHQ37NN)
 Date of issue:                  07-Oct-2019                                                        Template version 3.94
 Report No.:                     EMC_BO_002245 (v1.0)                          Copyright © 2019 Molex. All rights reserved.
                                                           20 (21)


                                        End of Report




Project support engineer:   Frank Wittmann                              FCC Test Report (XPY1EHQ37NN)
Date of issue:              07-Oct-2019                                           Template version 3.94
Report No.:                 EMC_BO_002245 (v1.0)             Copyright © 2019 Molex. All rights reserved.
                                                   21 (21)



Document Created: 2019-10-10 14:05:46
Document Modified: 2019-10-10 14:05:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC