RFID Test Report

FCC ID: XKB-M2500CL3G

Test Report

Download: PDF
FCCID_3372864

                                                                                      CETECOM ICT Services is now




                                                          TEST REPORT
                                                Test report no.: 1-2628/16-01-02

                  Testing laboratory                                                                Applicant
 CTC advanced GmbH                                                              Ingenico Group
 Untertuerkheimer Strasse 6 – 10                                                9 Avenue de la Gare Rovaltain
 66117 Saarbruecken / Germany                                                   26958 Valence Cedex 9 / FRANCE
 Phone:    + 49 681 5 98 - 0                                                    Phone:   -/-
 Fax:      + 49 681 5 98 - 9075                                                 Fax:     -/-
 Internet: http://www.ctcadvanced.com                                           Contact: Jean-Baptiste Palisse
 e-mail:   mail@ctcadvanced.com                                                 e-mail:  jean-baptiste.palisse@ingenico.com
                                                                                Phone:   +33 4 75 84 21 74
 Accredited Testing Laboratory:
 The testing laboratory (area of testing) is accredited
 according to DIN EN ISO/IEC 17025 (2005) by the
 Deutsche Akkreditierungsstelle GmbH (DAkkS)                                                      Manufacturer
 The accreditation is valid for the scope of testing                            Ingenico Group
 procedures as stated in the accreditation certificate with                     9 Avenue de la Gare Rovaltain
 the registration number: D-PL-12076-01-01                                      26958 Valence Cedex 9 / FRANCE


                                                                Test standard/s
 47 CFR Part 15                Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency
                               devices
 RSS-210 Issue 9               Licence-Exempt Radio Apparatus: Category I Equipment
 For further applied test standards please refer to section 3 of this test report.


                                                                         Test Item
 Kind of test item:           Mobile payment terminal
 Model name:                  Move/2500
 FCC ID:                      XKB-M2500CL3G
 IC:                          2586D-M2500CL3G
 Frequency:                   13.56 MHz
 Technology tested:           RFID
 Antenna:                     Integrated loop antenna
                              5.00 V DC by external 115 V AC power supply unit
 Power supply:                (P SM05A-0501-R) and
                              3.60 V DC by Li-Ion battery
 Temperature range:           -20°C to +50°C

This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures,
the public keys can be requested at the testing laboratory.


 Test report authorized:                                                      Test performed:
                               cn=Andreas Luckenbill, o=CTC advanced                                     cn=Marco Bertolino, o=CTC advanced GmbH,
                               GmbH, ou=LUC-170203,                                                      ou=BTL-161128,
                               email=Andreas.Luckenbill@ctcadvanced.co                                   email=Marco.Bertolino@ctcadvanced.com,
                               m, c=DE                                                                   c=DE
                               2017.02.14 10:49:25 +01'00'                                               2017.02.14 10:48:25 +01'00'

 Andreas Luckenbill                                                           Marco Bertolino
 Lab Manager                                                                  Lab Manager
 Radio Communications & EMC                                                   Radio Communications & EMC


                                                                                                                         CETECOM ICT Services is now
                 Test report no.: 1-2628/16-01-02




1      Table of contents

1    Table of contents ............................................................................................................................................2
2    General information .......................................................................................................................................3
     2.1       Notes and disclaimer ..........................................................................................................................3
     2.2       Application details ...............................................................................................................................3
     2.3       Test laboratories sub-contracted ......................................................................................................3
3    Test standard/s and references ....................................................................................................................4
4    Test environment............................................................................................................................................5
5    Test item ..........................................................................................................................................................5
     5.1       General description .............................................................................................................................5
     5.2       Additional information ........................................................................................................................5
6    Description of the test setup .........................................................................................................................6
     6.1       Shielded semi anechoic chamber ......................................................................................................7
     6.2       Shielded fully anechoic chamber ......................................................................................................8
     6.3       AC conducted ......................................................................................................................................9
     6.4       Test setup for normalized measurement configurations & frequency error...............................10
7    Sequence of testing .....................................................................................................................................11
     7.1       Sequence of testing radiated spurious 9 kHz to 30 MHz...............................................................11
     7.2       Sequence of testing radiated spurious 30 MHz to 1 GHz ..............................................................12
8    Measurement uncertainty ............................................................................................................................13
9    Summary of measurement results .............................................................................................................14
10      Additional comments ...............................................................................................................................14
11      Measurement results ................................................................................................................................15
     11.1         Occupied bandwidth......................................................................................................................15
     11.2         Field strength of the fundamental ................................................................................................17
     11.3         Field strength of the harmonics and spurious ...........................................................................18
     11.4         Conducted limits ............................................................................................................................21
     11.5         Frequency error .............................................................................................................................24
12      Observations .............................................................................................................................................25
Annex A           Document history ..........................................................................................................................25
Annex B           Further information........................................................................................................................25
Annex C           Accreditation Certificate ...............................................................................................................26




                                                                          Page 2 of 26


                                                                                   CETECOM ICT Services is now
             Test report no.: 1-2628/16-01-02




2      General information

2.1    Notes and disclaimer
The test results of this test report relate exclusively to the test item specified in this test report. CTC advanced
GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with
regard to other specimens or samples of the type of the equipment represented by the test item.
The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report
requires the prior written approval of CTC advanced GmbH.
The testing service provided by CTC advanced GmbH has been rendered under the current "General Terms and
Conditions for CTC advanced GmbH".
CTC advanced GmbH will not be liable for any loss or damage resulting from false, inaccurate, inappropriate or
incomplete product information provided by the customer.
Under no circumstances does the CTC advanced GmbH test report include any endorsement or warranty
regarding the functionality, quality or performance of any other product or service provided.
Under no circumstances does the CTC advanced GmbH test report include or imply any product or service
warranties from CTC advanced GmbH, including, without limitation, any implied warranties of merchantability,
fitness for purpose, or non-infringement, all of which are expressly disclaimed by CTC advanced GmbH.
All rights and remedies regarding vendor’s products and services for which CTC advanced GmbH has prepared
this test report shall be provided by the party offering such products or services and not by CTC advanced GmbH.
In no case this test report can be considered as a Letter of Approval.

This test report is electronically signed and valid without handwritten signature. For verification of the electronic
signatures, the public keys can be requested at the testing laboratory.



2.2    Application details
Date of receipt of order:                2016-12-08
Date of receipt of test item:            2017-02-01
Start of test:                           2017-02-01
End of test:                             2017-02-02
Person(s) present during the test:       -/-



2.3    Test laboratories sub-contracted
None




                                                   Page 3 of 26


                                                                          CETECOM ICT Services is now
           Test report no.: 1-2628/16-01-02




3   Test standard/s and references
Test standard           Date          Description
                                      Title 47 of the Code of Federal Regulations; Chapter I; Part 15 -
47 CFR Part 15          -/-
                                      Radio frequency devices
RSS-210 Issue 9         August 2016   Licence-Exempt Radio Apparatus: Category I Equipment
                                      Spectrum Management and Telecommunications Radio Standards
                        November
RSS - Gen Issue 4                     Specifications - General Requirements and Information for the
                        2014
                                      Certification of Radio Apparatus



Guidance                Version       Description
                                      American national standard for methods of measurement of radio-
ANSI C63.4-2014         -/-           noise emissions from low-voltage electrical and electronic
                                      equipment in the range of 9 kHz to 40 GHz
                                      American national standard of procedures for compliance testing
ANSI C63.10-2013        -/-
                                      of unlicensed wireless devices




                                           Page 4 of 26


                                                                                  CETECOM ICT Services is now
            Test report no.: 1-2628/16-01-02




4     Test environment

                                   Tnom    +22 °C during room temperature tests
Temperature                  :     Tmax    +50 °C during high temperature tests
                                   Tmin     -20 °C during low temperature tests
Relative humidity content    :             35 %
Barometric pressure          :             1021 hpa
                                   Vnom    5.00 V DC by external 115 V AC power supply unit
                                           (P SM05A-0501-R) and
Power supply                 :             3.60 V DC by Li-Ion battery
                                   Vmax    5.25 V DC
                                   Vmin    4.75 V DC



5     Test item

5.1   General description

Kind of test item            :   Mobile payment terminal
Type identification          :   Move/2500
HMN                          :   -/-
PMN                          :   Move/2500
HVIN                         :   Move/2500 CL/Eth/Mod/3G
FVIN                         :   -/-
S/N serial number            :   162793433221038700001778
HW hardware status           :   01
SW software status           :   OS : 032011 / APPLI : 006200
                                 13.553 MHz to 13.567 MHz
Frequency band               :
                                 Carrier frequency: 13.56 MHz
Type of radio transmission   :
                                 modulated carrier, clean carrier
Use of frequency spectrum    :
Type of modulation           :   OOK
Number of channels           :   1
Antenna                      :   Integrated loop antenna
                                 5.00 V DC by external 115 VAC power supply unit (P SM05A-0501-R) and
Power supply                 :
                                 3.60 V DC by Li-Ion battery
Temperature range            :   -20°C to +50°C




5.2   Additional information
The content of the following annexes is defined in the QA. It may be that not all of the listed annexes are
necessary for this report, thus some values in between may be missing.

Test setup- and EUT-photos are included in test report:         1-2628/16-01-01_AnnexA
                                                                1-2628/16-01-01_AnnexB
                                                                1-2628/16-01-01_AnnexD




                                                  Page 5 of 26


                                                                                           CETECOM ICT Services is now
                 Test report no.: 1-2628/16-01-02




6           Description of the test setup
Typically, the calibrations of the test apparatus are commissioned to and performed by an accredited calibration
laboratory. The calibration intervals are determined in accordance with the DIN EN ISO/IEC 17025. In addition to
the external calibrations, the laboratory executes comparison measurements with other calibrated test systems
or effective verifications. Weekly chamber inspections and range calibrations are performed. Where possible, RF
generating and signaling equipment as well as measuring receivers and analyzers are connected to an external
high-precision 10 MHz reference (GPS-based or rubidium frequency standard).

In order to simplify the identification of the equipment used at some special tests, some items of test equipment
and ancillaries can be provided with an identifier or number in the equipment list below (Lab/Item).



Agenda: Kind of Calibration

    k        calibration / calibrated                            EK      limited calibration
    ne       not required (k, ev, izw, zw not required)          zw      cyclical maintenance (external cyclical
                                                                         maintenance)
    ev       periodic self verification                          izw     internal cyclical maintenance
    Ve       long-term stability recognized                      g       blocked for accredited testing
    vlkI!    Attention: extended calibration interval
    NK!      Attention: not calibrated                           *)      next calibration ordered / currently in progress




                                                          Page 6 of 26


                                                                                          CETECOM ICT Services is now
                Test report no.: 1-2628/16-01-02




6.1     Shielded semi anechoic chamber
The radiated measurements are performed in vertical and horizontal plane in the frequency range from 9 kHz to
1 GHz in semi-anechoic chambers. The EUT is positioned on a non-conductive support with a height of 0.80 m
above a conductive ground plane that covers the whole chamber. The receiving antennas are conform to
specifications ANSI C63. These antennas can be moved over the height range between 1.0 m and 4.0 m in order
to search for maximum field strength emitted from EUT. The measurement distances between EUT and receiving
antennas are indicated in the test setups for the various frequency ranges. For each measurement, the EUT is
rotated in all three axes until the maximum field strength is received. The wanted and unwanted emissions are
received by spectrum analyzers where the detector modes and resolution bandwidths over various frequency
ranges are set according to requirement ANSI C63.




Measurement distance: tri-log antenna 10 meter

FS = UR + CL + AF
(FS-field strength; UR-voltage at the receiver; CL-loss of the cable; AF-antenna factor)

Example calculation:
FS [dBµV/m] = 12.35 [dBµV/m] + 1.90 [dB] + 16.80 [dB/m] = 31.05 [dBµV/m] (35.69 µV/m)


Equipment table:

        Lab /                                                                                 Kind of       Last        Next
  No.               Equipment             Type        Manufacturer    Serial No.    INV. No.
        Item                                                                                 Calibration Calibration Calibration
 1        A         Switch-Unit          3488A            HP          2719A14505   300000368     ev          -/-         -/-
 2        A      EMI Test Receiver       ESCI 3           R&S           100083     300003312      k      08.03.2016 08.03.2017
                Analyzer-Reference-
                                                                      A3509 07/0
 3       A      System (Harmonics       ARS 16/1          SPS                      300003314      Ve      02.02.2016   02.02.2018
                                                                        0205
                    and Flicker)
 4       A         Antenna Tower        Model 2175    ETS-Lindgren      64762      300003745      izw         -/-          -/-
                     Positioning
 5       A                              Model 2090    ETS-Lindgren      64672      300003746      izw         -/-          -/-
                     Controller
                Turntable Interface-
 6       A                             Model 105637   ETS-Lindgren      44583      300003747      izw         -/-          -/-
                        Box
                TRILOG Broadband
 7       A        Test-Antenna 30       VULB9163      Schwarzbeck        295       300003787       k      25.04.2016   25.04.2018
                    MHz - 3 GHz




                                                       Page 7 of 26


                                                                                               CETECOM ICT Services is now
                Test report no.: 1-2628/16-01-02




6.2     Shielded fully anechoic chamber




Measurement distance: loop antenna 3 meter

FS = UR + CA + AF
(FS-field strength; UR-voltage at the receiver; CA-loss of the signal path; AF-antenna factor)

Example calculation:
FS [dBµV/m] = 40.0 [dBµV/m] + (-35.8) [dB] + 32.9 [dB/m] = 37.1 [dBµV/m] (71.61 µV/m)


Equipment table:

        Lab /                                                                                      Kind of       Last        Next
  No.               Equipment            Type         Manufacturer         Serial No.    INV. No.
        Item                                                                                      Calibration Calibration Calibration
 1        A      Anechoic chamber       FAC 3/5m       MWB / TDK           87400/02     300000996     ev           -/-        -/-
 2        A     Switch / Control Unit    3488A           HP                   *         300000199     ne          -/-         -/-
                Active Loop Antenna
 3       A                                6502          EMCO/2            8905-2342     300000256       k      24.06.2015   24.06.2017
                 10 kHz to 30 MHz
                 EMI Test Receiver
 4       A                               ESU26            R&S               100037      300003555       k      31.01.2017   30.01.2018
                  20Hz- 26,5GHz
                   4U RF Switch
 5       A                              L4491A     Agilent Technologies   MY50000037    300004509      ne          -/-          -/-
                      Platform




                                                        Page 8 of 26


                                                                                             CETECOM ICT Services is now
                Test report no.: 1-2628/16-01-02




6.3     AC conducted




FS = UR + CF + VC
(FS-field strength; UR-voltage at the receiver; CR-loss of the cable and filter; VC-correction factor of the ISN)

Example calculation:
FS [dBµV/m] = 37.62 [dBµV/m] + 9.90 [dB] + 0.23 [dB] = 47.75 [dBµV/m] (244.06 µV/m)


Equipment table:

        Lab /                                                                                      Kind of       Last        Next
  No.               Equipment           Type        Manufacturer         Serial No.    INV. No.
        Item                                                                                      Calibration Calibration Calibration
                Two-line V-Network
 1       A       (LISN) 9 kHz to 30   ESH3-Z5           R&S             893045/004    300000584       k       31.01.2017   30.01.2018
                        MHz
 2       A        RF-Filter-section    85420E            HP             3427A00162    300002214       k       27.11.2006       -/-
                        AC-
 3       A        Spannungsquelle     MV2616-V        EM-Test             0397-12     300003259       k       11.12.2015   11.12.2017
                      variabel
 4       A       Hochpass 150 kHz      EZ-25            R&S               100010      300003798       ev      08.04.2008       -/-
                 MXE EMI Receiver
 5       A                            N9038A     Agilent Technologies   MY51210197    300004405       k       16.08.2016   16.08.2017
                 20 Hz to 26,5 GHz
                Analyzer-Reference-
                                                                        A3509 07/0
 6       A      System (Harmonics     ARS 16/1          SPS                           300003314       Ve      02.02.2016   02.02.2018
                                                                          0205
                    and Flicker)




                                                      Page 9 of 26


                                                                                                      CETECOM ICT Services is now
                Test report no.: 1-2628/16-01-02




6.4    Test setup for normalized measurement configurations & frequency error




Equipment table:

        Lab /                                                                                             Kind of       Last        Next
 No.                    Equipment                Type           Manufacturer      Serial No.    INV. No.
        Item                                                                                             Calibration Calibration Calibration
 1        B       Temperature Test Chamber       VT 4002       Heraeus Voetsch   521/83761     300002326     ev      03.09.2015 03.09.2017
                                             -/-, 5-45C, 20-
 2      A; B         Hygro-Thermometer                         Heraeus Voetsch       -/-       400000108      ev      07.09.2015   07.09.2017
                                                   100rF
 3      A; B       Signal Analyzer 40 GHz         FSV40             R&S            101042      300004517       k      27.01.2017   26.01.2018
                                                                   Agilent
 4       B        Power Supply 0-20V, 0-5A       6632B                           GB42110541    400000562     vlKI!    26.01.2016   26.01.2019
                                                                Technologies
                                             ST18/SMAm/                           Batch no.
 5      A; B             RF-Cable                              Huber & Suhner                  400001182      ev          -/-          -/-
                                              SMAm/48                              600918
                                                                                  Batch no.
 6      A; B       DC-Blocker 0.1-40 GHz        8141A               Inmet                      400001185      ev          -/-          -/-
                                                                                   600918




                                                                Page 10 of 26


                                                                                   CETECOM ICT Services is now
            Test report no.: 1-2628/16-01-02




7     Sequence of testing

7.1   Sequence of testing radiated spurious 9 kHz to 30 MHz
Setup
    The equipment is set up to simulate normal operation mode as described in the user manual or defined
      by the manufacturer.
    If the EUT is a tabletop system, a 2-axis positioner with 1.5 m height is used.
    If the EUT is a floor standing device, it is placed directly on the turn table.
    Auxiliary equipment and cables are positioned to simulate normal operation conditions as described in
      ANSI C 63.4.
    The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    Measurement distance is 3 m (see ANSI C 63.4) – see test details.
    EUT is set into operation.

Premeasurement
    The turntable rotates from 0° to 315° using 45° steps.
    The antenna height is 1.5 m.
    At each turntable position the analyzer sweeps with positive-peak detector to find the maximum of all
      emissions.

Final measurement
     Identified emissions during the premeasurement are maximized by the software by rotating the turntable
       from 0° to 360°. In case of the 2-axis positioner is used the elevation axis is also rotated from 0° to 360°.
     The final measurement is done in the position (turntable and elevation) causing the highest emissions
       with quasi-peak (as described in ANSI C 63.4).
     Final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the
       limit and limit will be recorded. A plot with the graph of the premeasurement and the limit is stored.




                                                  Page 11 of 26


                                                                                CETECOM ICT Services is now
            Test report no.: 1-2628/16-01-02




7.2   Sequence of testing radiated spurious 30 MHz to 1 GHz
Setup
    The equipment is set up to simulate normal operation mode as described in the user manual or defined
      by the manufacturer.
    If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
    If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    Auxiliary equipment and cables are positioned to simulate normal operation conditions as described in
      ANSI C 63.4.
    The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    Measurement distance is 10 m or 3 m (see ANSI C 63.4) – see test details.
    EUT is set into operation.

Premeasurement
    The turntable rotates from 0° to 315° using 45° steps.
    The antenna is polarized vertical and horizontal.
    The antenna height changes from 1 m to 3 m.
    At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to
      find the maximum of all emissions.

Final measurement
     The final measurement is performed for at least six highest peaks according to the requirements of the
       ANSI C63.4.
     Based on antenna and turntable positions at which the peak values are measured the software maximize
       the peaks by changing turntable position ± 45° and antenna height between 1 and 4 m.
     The final measurement is done with quasi-peak detector (as described in ANSI C 63.4).
     Final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle,
       correction factor, margin to the limit and limit are recorded. A plot with the graph of the premeasurement
       with marked maximum final results and the limit is stored.




                                                 Page 12 of 26


                                                                       CETECOM ICT Services is now
          Test report no.: 1-2628/16-01-02




8    Measurement uncertainty

                                       Measurement uncertainty
                          Test case                                        Uncertainty
Occupied bandwidth                                            ± used RBW
Field strength of the fundamental                             ± 3 dB
Field strength of the harmonics and spurious                  ± 3 dB
Receiver spurious emissions and cabinet radiations            ± 3 dB
Conducted limits                                              ± 2.6 dB




                                              Page 13 of 26


                                                                                        CETECOM ICT Services is now
              Test report no.: 1-2628/16-01-02




9       Summary of measurement results

         ☒           No deviations from the technical specifications were ascertained
         ☐           There were deviations from the technical specifications ascertained
                     This test report is only a partial test report. The content and verdict of the performed test cases
         ☐           are listed below.

    TC Identifier                    Description                       Verdict            Date               Remark
                                     CFR Part 15
     RF-Testing                    RSS-210 Issue 9                    See table!     2017-02-14                -/-
                                   RSS Gen Issue 4

         Test
                                                Temperature Power source
    specification           Test case                                               C      NC     NA    NP     Remark
                                                 conditions  conditions
       clause
      RSS Gen
       Issue 4
                       Occupied bandwidth         Nominal           Nominal         ☒       ☐     ☐     ☐            -/-

    § 15.225 (a)
                       Field strength of the
     RSS-210
                           fundamental
                                                  Nominal           Nominal         ☒       ☐     ☐     ☐            -/-
    Issue 9 B.6

       § 15.209
          &            Field strength of the
    § 15.225 (b-d)        harmonics and           Nominal           Nominal         ☒       ☐     ☐     ☐            -/-
      RSS-210                spurious
     Issue 9 B.6

                                                                                                              No stand-
      § 15.109         Receiver spurious
                                                                                                                alone
      RSS Gen         emissions and cabinet       Nominal           Nominal         ☐       ☐     ☒     ☐      receiver
       Issue 4              radiations
                                                                                                                mode!

      §15.107
      §15.207
                         Conducted limits         Nominal           Nominal         ☒       ☐     ☐     ☐            -/-

    § 15.225 (a)                                 Normal &          Normal &
     RSS-210           Frequency tolerance        extreme           extreme         ☒       ☐     ☐     ☐            -/-
    Issue 9 B.6                                  conditions        conditions


Note:
 C         Compliant
 NC        Not compliant
 NA        Not applicable
 NP        Not performed



10      Additional comments
Reference documents:                None

Special test descriptions:          None

Configuration descriptions:         None

                                                      Page 14 of 26


                                                                              CETECOM ICT Services is now
             Test report no.: 1-2628/16-01-02




11       Measurement results

11.1 Occupied bandwidth
Measurement:

The emission bandwidth (x dB) is defined as the frequency range between two points, one above and one
below the carrier frequency, at which the spectral density of the emission is attenuated x dB below the
maximum in-band spectral density of the modulated signal.

                                         Measurement parameters
 Detector:                                            Peak
 Resolution bandwidth:                                1 % – 5 % of the occupied bandwidth
 Video bandwidth:                                     ≥ 3x RBW
 Trace mode:                                          Max hold
 Analyzer function:                                   99 % power function
 Used equipment:                                      See chapter 6.4 - A
 Measurement uncertainty:                             See chapter 8



Limit:

                                                     IC
                                   for RSP-100 test report coversheet only



Result:

                                         99% emission bandwidth
                                               129.9 kHz




                                               Page 15 of 26


                                                              CETECOM ICT Services is now
           Test report no.: 1-2628/16-01-02



Plot:

Plot 1: 99 % emission bandwidth




                Date: 2.FEB.2017   14:54:35




                                              Page 16 of 26


                                                                                                                 CETECOM ICT Services is now
             Test report no.: 1-2628/16-01-02




11.2 Field strength of the fundamental
Measurement:

The maximum detected field strength for the carrier signal.

                                                  Measurement parameters
 Detector:                                                     Quasi peak / peak (worst case)
 Resolution bandwidth:                                         120 kHz
 Video bandwidth:                                              ≥ 3x RBW
 Trace mode:                                                   Max hold
 Used equipment:                                               See chapter 6.2 - A
 Measurement uncertainty:                                      See chapter 8



Limit:

                                                              FCC & IC
             Frequency                                      Field strength                                        Measurement distance
               (MHz)                                            (µV/m)                                                   (m)
          13.553 to 13.567                               15,848 (84 dBµV/m)                                               30



Recalculation:

                                                  According to ANSI C63.10
                                                                                                                         Correction value
          Frequency                                                Formula
                                                                                                                         from 3m to 30m
                                    FSlimit = FSmax 40 log                                  20log
                                                                                nearfield
                                                                                                             )

                                FSlimit        is the calculation of field strength at the limit distance,
          13.56 MHz                            expressed in dBµV/m
                                                                                                                            -21.39 dB
                                FSmax          is the measured field strength, expressed in dBµV/m
                                dnear field    is the λ/2π distance
                                dmeasure       is the distance of the measurement point from EUT
                                dlimit         is the reference limit distance




                                                  According to ANSI C63.10

Result:

                                              Field strength of the fundamental
 Frequency                                                                13.56 MHz
 Distance                                                    @3m                                                          @ 30 m
                                                      81.3 dBµV/m (Peak)                                            59.9 dBµV/m (Peak)
 Measured / calculated value
                                                       75.2 dBµV/m (QP)                                              53.8 dBµV/m (QP)




                                                              Page 17 of 26


                                                                               CETECOM ICT Services is now
              Test report no.: 1-2628/16-01-02




11.3 Field strength of the harmonics and spurious
Measurement:

The maximum detected field strength for the harmonics and spurious.

                                          Measurement parameters
                                                       Quasi peak / average or
 Detector:
                                                       peak (worst case – pre-scan)
                                                       F < 150 kHz: 200 Hz
 Resolution bandwidth:                                 150 kHz < F < 30 MHz: 9 kHz
                                                       30 MHz < F < 1 GHz: 120 kHz
                                                       F < 150 kHz: 1 kHz
 Video bandwidth:                                      150 kHz < F < 30 MHz: 100 kHz
                                                       30 MHz < F < 1 GHz: 300 kHz
 Trace mode:                                           Max hold
                                                       See chapter 6.1 – A
 Used equipment:                                       See chapter 6.2 – A
                                                       See chapter 6.4 – A
 Measurement uncertainty:                              See chapter 8



Limit:

                                                  FCC & IC
              Frequency                         Field strength                   Measurement distance
                 (MHz)                            (dBµV/m)                              (m)
             0.009 – 0.490                       2400/F(kHz)                            300
             0.490 – 1.705                      24000/F(kHz)                             30
              1.705 – 30                      30 (29.5 dBµV/m)                           30
                30 – 88                        100 (40 dBµV/m)                           3
               88 – 216                       150 (43.5 dBµV/m)                          3
               216 – 960                       200 (46 dBµV/m)                           3

Note:      For a reduced measurement distance, please take a look at the limit line and the ANSI C63.10-2013
           sub clause 6.4 radiated emissions from unlicensed wireless devices below 30 MHz.



Result:

                                            Detected emissions
          Frequency                                     Resolution bandwidth             Detected value
                                    Detector
            (MHz)                                               (kHz)                   (dBµV/m @ 3m)
                                      Peak                         9                          38.7
             12.7
                                       QP                          9                          24.5
                                      Peak                         9                          40.1
             27.1
                                       QP                          9                          31.7
             For emissions between 30 MHz and 1 GHz, please loot at the table below the 1 GHz plot.




                                                 Page 18 of 26


                                                                             CETECOM ICT Services is now
                      Test report no.: 1-2628/16-01-02



Plots:

Plot 1: 9 kHz – 30 MHz, magnetic emissions
         130
dBµV/m
         120

         110

         100

          90

          80

          70

          60

          50

          40

          30

          20

          10
               9kHz                         100k                        1M                    10M          30MHz
                                                            Frequency




Plot 2: Spectrum mask (the limits are recalculated according to the ANSI C63.10-2013 sub clause 6.4)




                                                     Page 19 of 26


                                                                                                            CETECOM ICT Services is now
            Test report no.: 1-2628/16-01-02




Plot 3: 30 MHz – 1 GHz, vertical and horizontal polarization



                              60

                              55

                              50

                              45                                                                                      FCC_10m_B

                              40
            Level in dBµV/m




                              35

                              30

                              25

                              20

                              15

                              10

                              5

                              0
                              30M              50   60      80 100M                 200      300      400   500         800     1,05G
                                                                         Frequency in Hz



Final_Result:

    Frequency                      QuasiPeak      Limit       Margin     Meas. Time       Bandwidth     Height           Azimuth        Corr.
                                                                                                                  Pol
      (MHz)                        (dBµV/m)     (dBµV/m)       (dB)        (ms)             (kHz)        (cm)             (deg)         (dB)
    40.662150                        29.98          30.00       0.02       1000.0          120.000      103.0     V            -3.0     13.3
    54.225900                        21.60          30.00       8.40       1000.0          120.000      203.0     V           275.0     13.2
    67.791750                        22.50          30.00       7.50       1000.0          120.000      203.0     V           198.0     10.2
   124.583550                        20.03          33.50      13.47       1000.0          120.000      100.0     V            88.0      9.9
   399.986550                        26.62          36.00       9.38       1000.0          120.000      200.0     H            84.0     16.9
   696.884400                        19.30          36.00      16.70       1000.0          120.000      200.0     V           132.0     21.5




                                                                       Page 20 of 26


                                                                              CETECOM ICT Services is now
             Test report no.: 1-2628/16-01-02




11.4 Conducted limits
Measurement:

Measurement of the conducted spurious emissions for an intentional radiator that is designed to be connected
to the public utility (AC) power line.

                                         Measurement parameters
                                                      Quasi peak / average or
 Detector:
                                                      peak (worst case – pre-scan)
                                                      F < 150 kHz:        200 Hz
 Resolution bandwidth:
                                                      F > 150 kHz:        9 kHz
                                                      F < 150 kHz:        1 kHz
 Video bandwidth:
                                                      F > 150 kHz:        100 kHz
 Trace mode:                                          Max hold
 Used equipment:                                      See chapter 6.3 - A
 Measurement uncertainty:                             See chapter 8



Limit:

                                                  FCC & IC
              Frequency                          Quasi-peak                             Average
                (MHz)                             (dBµV/m)                             (dBµV/m)
               0.15 – 0.5                          66 to 56                             56 to 46
                 0.5 – 5                              56                                   46
                5 – 30.0                              60                                   50




Result:

                                            Detected emissions
          Frequency                                     Resolution bandwidth
                                    Detector                                            Detected value
            (MHz)                                               (kHz)
                                         See table below the plots.




                                                Page 21 of 26


                                                                                                            CETECOM ICT Services is now
                     Test report no.: 1-2628/16-01-02



Plots:

Plot 1: 150 kHz to 30 MHz, phase line


                                                                                                                              Premeasurement
                                                                                                                              Average limit class B
                                                                                                                              Quasi peak limit class B
                                                                        Measurement                                           Average level
                                                                                                                              Quasi peak level

                                                                          Phase line




                               80.0




                               70.0




                               60.0




                               50.0
           Amplitude in dBµV




                               40.0




                               30.0




                               20.0




                               10.0




                                  0
                                 150.0K                        1.0M                                      10.0M                                        30.0M

                                                                        Frequency in Hz

                                                                                                    Project ID: 1-2628/16-01-02




                                          Quasi peak     Margin                           Average                  Margin
  Frequency                                                             Limit OQ                                                                              Limit AV
                                            level      quasi peak                          level                   average
     MHz                                    dBµV          dB             dBµV              dBµV                      dB                                       dBµV
  0.164252                                  47.40        17.85           65.246            34.12                    21.47                                     55.593
  0.500767                                  42.90        13.10           56.000            33.54                    12.46                                     46.000
  0.556723                                  33.74        22.26           56.000            24.59                    21.41                                     46.000
  0.611520                                  33.99        22.01           56.000            24.60                    21.40                                     46.000
  1.095489                                  31.79        24.21           56.000            24.28                    21.72                                     46.000
  2.394942                                  31.78        24.22           56.000            22.40                    23.60                                     46.000
  2.840708                                  31.16        24.84           56.000            22.02                    23.98                                     46.000
  3.224195                                  28.42        27.58           56.000            21.31                    24.69                                     46.000
  24.002179                                 29.31        30.69           60.000            22.20                    27.80                                     50.000
  25.780127                                 29.29        30.71           60.000            22.40                    27.60                                     50.000
  27.464574                                 30.35        29.65           60.000            23.06                    26.94                                     50.000
  27.736276                                 29.54        30.46           60.000            22.38                    27.62                                     50.000




                                                                      Page 22 of 26


                                                                                                            CETECOM ICT Services is now
                     Test report no.: 1-2628/16-01-02




Plot 2: 150 kHz to 30 MHz, neutral line


                                                                                                                              Premeasurement
                                                                                                                              Average limit class B
                                                                                                                              Quasi peak limit class B
                                                                        Measurement                                           Average level
                                                                                                                              Quasi peak level

                                                                          Neutral line




                               80.0




                               70.0




                               60.0




                               50.0
           Amplitude in dBµV




                               40.0




                               30.0




                               20.0




                               10.0




                                  0
                                 150.0K                        1.0M                                      10.0M                                        30.0M

                                                                        Frequency in Hz

                                                                                                    Project ID: 1-2628/16-01-02




                                          Quasi peak     Margin                           Average                  Margin
  Frequency                                                             Limit OQ                                                                              Limit AV
                                            level      quasi peak                          level                   average
     MHz                                    dBµV          dB             dBµV              dBµV                      dB                                       dBµV
  0.198051                                  41.69        22.00           63.692            28.79                    25.84                                     54.627
  0.220314                                  45.04        17.77           62.807            31.29                    22.70                                     53.991
  0.501369                                  42.97        13.03           56.000            34.53                    11.47                                     46.000
  0.559424                                  33.13        22.87           56.000            24.00                    22.00                                     46.000
  1.058870                                  34.44        21.56           56.000            23.90                    22.10                                     46.000
  1.169553                                  32.62        23.38           56.000            22.64                    23.36                                     46.000
  1.225734                                  31.67        24.33           56.000            22.38                    23.62                                     46.000
  2.340955                                  31.66        24.34           56.000            22.42                    23.58                                     46.000
  24.015136                                 30.32        29.68           60.000            22.66                    27.34                                     50.000
  26.344510                                 29.63        30.37           60.000            22.68                    27.32                                     50.000
  28.948971                                 29.84        30.16           60.000            22.39                    27.61                                     50.000
  29.303840                                 30.56        29.44           60.000            22.76                    27.24                                     50.000




                                                                      Page 23 of 26


                                                                             CETECOM ICT Services is now
            Test report no.: 1-2628/16-01-02




11.5 Frequency error
Measurement:

The maximum detected field strength for the spurious.

                                         Measurement parameters
 Detector:                                            Peak detector
 Resolution bandwidth:                                10 Hz / 100 Hz
 Video bandwidth:                                     > RBW
 Trace mode:                                          Max hold
 Used equipment:                                      See chapter 6.4 – B
 Measurement uncertainty:                             See chapter 8



Limit:

                                                  FCC & IC
    FCC: The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the
 operating frequency over a temperature variation of -20 degrees to +50 degrees C at normal supply
   voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply
                       voltage at a temperature of 20 degrees C. (±1.356 kHz)

                                               IC: ± 100 ppm




Result: Temperature variation

                                             Frequency tolerance
   Measured frequency           Frequency error
                                                            Conditions                      Result
         (MHz)                       (kHz)
      13.5597179                    0.282            -20 °C & 100% voltage                compliant
      13.5596976                    0.302            -10 °C & 100% voltage                compliant
      13.5596470                    0.353              0 °C & 100% voltage                compliant
      13.5596310                    0.369            +10 °C & 100% voltage                compliant
      13.5596035                    0.397            +20 °C & 100% voltage                compliant
      13.5595920                    0.408            +30 °C & 100% voltage                compliant
      13.5595891                    0.411            +40 °C & 100% voltage                compliant
      13.5595963                    0.404            +50 °C & 100% voltage                compliant



Result: Voltage variation

                                             Frequency tolerance
   Measured frequency           Frequency error
                                                            Conditions                      Result
         (MHz)                       (kHz)
      13.5596556                    0.344             +20 °C & 85% voltage                compliant
      13.5596542                    0.346            +20 °C & 100% voltage                compliant
      13.5596498                    0.350            +20 °C & 115% voltage                compliant




                                               Page 24 of 26


                                                                             CETECOM ICT Services is now
               Test report no.: 1-2628/16-01-02




12    Observations
No observations except those reported with the single test cases have been made.



Annex A          Document history

  Version                                  Applied changes                                  Date of release

                                             Initial release                                  2017-02-14




Annex B          Further information
Glossary

AVG        -    Average
DUT        -    Device under test
EMC        -    Electromagnetic Compatibility
EN         -    European Standard
EUT        -    Equipment under test
ETSI       -    European Telecommunications Standard Institute
FCC        -    Federal Communication Commission
FCC ID     -    Company Identifier at FCC
HW         -    Hardware
IC         -    Industry Canada
Inv. No.   -    Inventory number
N/A        -    Not applicable
PP         -    Positive peak
QP         -    Quasi peak
S/N        -    Serial number
SW         -    Software
PMN        -    Product marketing name
HMN        -    Host marketing name
HVIN       -    Hardware version identification number
FVIN       -    Firmware version identification number
OBW             Occupied Bandwidth
OC              Operating Channel
OCW             Operating Channel Bandwidth
OOB             Out Of Band




                                                Page 25 of 26


                                                                      CETECOM ICT Services is now
           Test report no.: 1-2628/16-01-02




Annex C       Accreditation Certificate


                       first page                                     last page




Note:
The current certificate including annex can be received on request.




                                             Page 26 of 26



Document Created: 2017-02-14 10:49:25
Document Modified: 2017-02-14 10:49:25

© 2024 FCC.report