Test Report

FCC ID: XKB-IUR250

Test Report

Download: PDF
FCCID_1654346

Rapport d’essai / Test report
JDE : 110116                    N° 249971-R1-E


DELIVRE A / ISSUED TO                                     : INGENICO
                                                            M. LEBONNOIS Etienne
                                                            1 Rue Claude Chappe
                                                            B.P. 348
                                                            07503 GUILHERAND GRANGES
Objet / Subject                                           : Essais de compatibilité électromagnétique conformément aux normes :
                                                            Electromagnetic compatibility tests according to the standards:
                                                            FCC CFR 47 Part 15, Subpart B.
                                                            ANSI C63.4 (2003)

Matériel testé / Apparatus under test                     :
 •  Produit / Product                                     :   IUR250
 •  Marque / Trade mark                                   :   INGENICO
 •  Constructeur / Manufacturer                           :   INGENICO
 •  Type / Model                                          :   IUR250-01T1659A
 •  N° de série / serial number                           :   11293IU00000518
 •  FCCID                                                     XKB-IUR250
                                                                                                                                       st        th
Date des essais / Test date                               : Du 21 au 29 Novembre 2011 / From November 21 to 29 , 2011

Lieu d’essai / Test location                              : LCIE SUD-EST
                                                            ZI Centr’Alp – 170 rue de Chatagnon
                                                            38430 MOIRANS - FRANCE

Test réalisé par / Test performed by                      : Anthony MERLIN / Nicolas BILLAUD

document comporte / Composition of document: 15 pages

                                                                                            MOIRANS, LE 31 JANVIER 2012 / JANUARY 31ST, 2012

 Ecrit par / Written by,                                                                    Approuvé par / Approved by,
 Anthony MERLIN                                                                             Jacques LORQUIN




 La reproduction de ce document n'est autorisée que sous sa forme intégrale. Toute reproduction partielle ou toute insertion de résultats dans un texte
 d'accompagnement en vue de leur diffusion doit recevoir un accord préalable et formel du LCIE. Ce document résulte d’essais effectués sur un spécimen, un échantillon
 ou une éprouvette. Il ne préjuge pas de la conformité de l’ensemble des produits fabriqués à l’objet essayé. Sauf indication contraire, la décision de conformité prend en
 compte l’incertitude de mesures. Il ne préjuge en aucun cas d’une décision de certification.
 This document shall not be reproduced, except in full, without t he written approval of the LCIE. This document contains results related only to the item tested. It does not
 imply the conformity of the whole production to the item tested .Unless otherwise specified; the decision of conformity takes into account the uncertainty of measures.
 This document does not anticipate any certification decision.


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                                                                   Page : 2 / 15



                                                                 SUMMARY



1.   TEST PROGRAM ................................................................................................................................... 3
2.   APPARATUS UNDER TEST: CONFIGURATION ................................................................................... 4
3.   MEASUREMENT OF CONDUCTED EMISSION (150KHZ-30MHZ) ....................................................... 5
4.   MEASUREMENT OF RADIATED EMISSION (30MHZ-1GHZ) ................................................................ 7
5.   UNCERTAINTIES CHART .................................................................................................................... 11
6.   ANNEX 1 (GRAPHS) ............................................................................................................................ 12


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                                                                   Page : 3 / 15


1.        TEST PROGRAM

Standard:                   - FCC Part 15, Subpart B (Digital Devices)
                            - ANSI C63.4 (2003)

 EMISSION TEST                                           LIMITS                                                 RESULTS
                                                                                                                (Comments)
 Limits for conducted disturbance at mains                            Quasi-peak     Average      COMPLY
                                                         Frequency
 ports                                                                value (dBµV)   value (dBµV)
 150kHz-30MHz                                            150-500kHz       66 to 56      56 to 46
                                                         0.5-5MHz            56           46
                                                         5-30MHz             60           50
 Radiated emissions                                      Measure at 3m                            COMPLY
 30MHz-1GHz*                                             30MHz-88MHz : 40 dBµV/m
                                                         88MHz-216MHz : 43.5 dBµV/m
                                                         216MHz-960MHz : 46.0 dBµV/m
                                                         Above 960MHz : 54.0 dBµV/m

*§15.33: The highest internal source of a testing device is defined like more the highest frequency generated or used in the testing device or on which
the testing device works or agrees.
- If the highest frequency of the internal sources of the testing device is lower than 108 MHz, measurement must be only performed until 1GHz.
- If the highest frequency of the internal sources of the testing device ranges between 108 MHz and 500 MHz, measurement must be only performed
until 2GHz.
- If the highest frequency of the internal sources of the testing device ranges between 500 MHz and 1 GHz, measurement must be only performed
until 5GHz.
If the highest frequency of the internal sources of the testing device is above 1 GHz, measurement must be only performed until 5 times the highest
frequency or 40 GHz, while taking smallest of both.
Highest frequency: 58MHz (Declaration of provider)


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                                          Page : 4 / 15


2.         APPARATUS UNDER TEST: CONFIGURATION

2.1.       HARDWARE IDENTIFICATION (EUT AND AUXILIARIES):

       •   Equipment under test (EUT):

IUR250-01T1659A                                                   Serial Number: 11293IU00000518
FCCID: XKB-IUR250

• Option:
- Motorised blocking of card, option installed in serial number tested.
IUR250-01T1659A can be provided with or without this option.


• Power supply:
- USB
- Rating: 5VDC
- Frequency: DC


• Inputs/outputs:
- 1 x USB port
- 1 x SMART CARD
- 1 x Earth
- 1 x RJ11, not used, maintenance only, not tested.


• Cables:
- 1 x USB shielded cable
- 1 x plait of mass


• Auxiliaries equipment used during test:
- 1 x IUP250-01T1760A - SN: 11293IU00000311
- 1 x laptop TOSHIBA SATELITE S1410-704 (PS141E-04YCM-3V), sn: 13594938G


2.2.       RUNNING MODE

The EUT exercise program used during testing was exercised the EUT in a manner similar to a typical use.
Test is done in loop we check that the number of tested loop is continuously increasing and that no error is reported on
the screen of the IUP250 for conducted emission test. For radiated emission test we used the laptop and we check that
the IUR is well functioning before and after measures.


2.3.       EQUIPMENT MODIFICATIONS

None


2.4.       SPECIAL ACCESSORIES

None


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                                     Page : 5 / 15


3.     MEASUREMENT OF CONDUCTED EMISSION (150KHZ-30MHZ)

3.1.   TEST CONDITIONS
                                     st
Date of test           : November 21 , 2011
Test performed by      : A. MERLIN / N. BILLAUD
Atmospheric pressure   : 992hPa
Relative humidity      : 29%
Ambient temperature    : 25.0°C


3.2.   SETUP FOR CONDUCTED EMISSIONS MEASUREMENT

The product has been tested according to ANSI C63.4-(2003) and FCC Part 15 subpart B.

The product has been tested with 110V/60Hz power line voltage and compared to the FCC Part 15 subpart B §15.107
limits. Measurement bandwidth was 9kHz from 150 kHz to 30 MHz.

The EUT with its auxiliaries are set on a non-conducting table 80cm above the ground reference plane.
The distance between the EUT and the LISN is 80cm. The EUT is 40cm away for the vertical ground plane.
The EUT is powered through a LISN (measure). Auxiliaries are powered by another LISN.

Measurement is made with a Rohde & Schwarz ESU8 receiver in peak mode. This was followed by a Quasi-Peak, i.e.
CISPR measurement for any strong signal. If the average limit is met when using a Quasi-Peak detector, the EUT shall
be deemed to meet both limits and measurement with the average detector is unnecessary. The LISN (measure and
auxiliaries) is 50Ω / 50µH.

The Peak data are shown on plots in annex 1. Quasi-Peak and Average measurements are detailed in a table with
frequencies and levels measured.

Interconnecting cables and equipment's were moved to position that maximized emission. A summary of the worst case
emissions found in all test configurations and modes is shown on the following page.


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                                    Page : 6 / 15




3.3.   TEST EQUIPMENT LIST

                         DESCRIPTION            MANUFACTURER             MODEL       N° LCIE
                       Receiver 20Hz – 8GHz      ROHDE & SCHWARZ          ESU8       A2642019
                          Transient limiter      HEWLETT PACKARD         11947A      A4049061
                               Cable                     -                  -        A5329197
                               LISN                    EMCO               3825/2     C2320068




3.4.   DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION

None


3.5.   MEASUREMENTS RESULTS

 Mains terminals 110Vac/60Hz:

Measurements are performed on the phase (L1) and neutral (N) of the power line of the IUP250.

Measure on L1: graph Emc#1                            (see annex 1)
Measure on N: graph Emc#2                             (see annex 1)

RESULT: PASS


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                                        Page : 7 / 15


4.     MEASUREMENT OF RADIATED EMISSION (30MHZ-1GHZ)

4.1.   TEST CONDITIONS
                                      th
Date of test           : November 29 , 2011
Test performed by      : A. MERLIN / N. BILLAUD
Atmospheric pressure   : 999hPa
Relative humidity      : 29%
Ambient temperature    : 22.0°C


4.2.   SETUP FOR RADIATED EMISSIONS MEASUREMENT

The installation of EUT is identical for pre-characterization measures in a 3 meters semi-anechoic chamber and for
measures on the 10 meters Open site.
The EUT and auxiliaries are set on the non-conducting table of 80 cm height.
The EUT is powered by 230Vac/50Hz (PC and auxiliaries)

Pre-characterisation measurement:
A pre-scan of all the setup has been performed in a 3 meters semi-anechoic chamber. The distance between EUT and
antenna is 3 meters. Test is performed in horizontal (H) and vertical (V) polarization. During the measurement, the EUT
is rotated on a 360° range.
The pre-characterization graphs are obtained in PEAK detection.
For frequency band 1GHz to 12.5GHz, a search is performed in the semi-anechoic chamber in order to determine
frequencies radiated by the EUT (Measuring distance reduced to 1m).

Characterization on 10 meters open site from 30MHz to 1GHz:
The product has been tested according to ANSI C63.4 (2003), FCC part 15 subpart B. Radiated Emissions were
measured on an open area test site. A description of the facility is on file with the FCC.

The product has been tested at a distance of 10 meters (30MHz to 1GHz) from the antenna and corrected according to
requirements of 15.109.e).
Results are compared to the FCC part 15 subpart B §15.109 limits.
Measurement bandwidth was 120kHz from 30 MHz to 1GHz.
Antenna height search was performed from 1m to 4m for both horizontal and vertical polarization. Continuous linear
turntable azimuth search was performed with 360 degrees range.


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                   Page : 8 / 15




                                Radiated emission test setup


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                                       Page : 9 / 15



4.3.    TEST EQUIPMENT LIST

                          DESCRIPTION                   MANUFACTURER       MODEL        N° LCIE
                        Receiver 20Hz – 8GHz            ROHDE & SCHWARZ        ESU8     A2642019
                   Radiated emission comb generator         BARDET               -      A3169050
                                 Cable                         -                 -      A5329183
                                 Cable                      UTIFLEX              -      A5329189
                      Semi-Anechoic chamber #1              SIEPEL               -      D3044016
                            Antenna Bi-log                  CHASE         CBL6111A      C2040172
                              Cable N/N                        -                 -      A5329038
                              Cable N/N                        -                 -      A5329206
                      Semi-Anechoic chamber #3              SIEPEL               -      D3044017
                            Antenna Bi-log                  CHASE         CBL6111A      C2040051

                                 Cable                     SUCOFLEX            106G     A5329061
                      Cable OATS (Mast at 10m)              UTIFLEX              -      A5329188
                      Cable OATS (Mast at 10m)              UTIFLEX              -      A5329199
                                OATS                           -                 -      F2000409
                   Turntable / Mast controller (OATS)     ETS Lindgren    Model 2066    F2000372
                         Antenna mast (OATS)              ETS Lindgren         2071-2   F2000392
                           Turntable (OATS)               ETS Lindgren    Model 2187    F2000403




4.4.    DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION

None


4.5.    MEASUREMENTS RESULTS

Pre-characterisation measurement: pre-scan measurement at 3m (PEAK detection, graph examples)
                Polarisation H: graph Emr#1        (see annex 1)
                Polarisation V: graph Emr#2        (see annex 1)

QUALIFICATION: 10 meters measurement on the Open Area Test Site.

Frequency list has been created with semi-anechoic chamber pre-scan results.
Measurements are performed using a QUASI-PEAK detection.

Frequency range 30MHz to 1GHz:
Measurements are performed using a QUASI-PEAK detection (RBW=120kHz)

   No     Frequency     Limit      Measure     Margin     Angle Pol       Ht    Correc.    Comments
            (MHz)    Quasi-Peak Quasi-Peak (Mes-Lim) Table Ant. Ant.            factor
                      (dBµV/m)     (dBµV/m)     (dB)       (deg)        (cm)     (dB)
   1       44.280       40.0         27.6       -12.4        0     V     100     11.6         PASS
   2       60.320       40.0         28.0       -12.0       180    V     200      6.5         PASS
Note: Measures have been done at 10m distance and corrected according to requirements of 15.109.e)
(M@3m = M@10m+10.5dB)


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                                         Page : 10 / 15



4.6.    Field Strength Calculation

The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting the Amplifier Gain (if
any) from the measured reading. The basic equation with a sample calculation is as follow:

FS = RA + AF + CF – AG

Where       FS = Field Strength
            RA = Receiver Amplitude
            AF = Antenna Factor
            CF = Cable Factor
            AG = Amplifier Gain

Assume a receiver reading of 52.5dBµV is obtained. The antenna factor of 7.4 and a cable factor of 1.1 is added. The
amplifier gain of 29dB is subtracted, giving field strength of 32 dBµV/m.
FS = 52.5 + 7.4 + 1.1 – 29 = 32 dBµV/m
The 32 dBµV/m value can be mathematically converted to its corresponding level in µV/m.
Level in µV/m = Common Antilogarithm [(32dBµV/m)/20] = 39.8 µV/m.


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                                              Page : 11 / 15


5.      UNCERTAINTIES CHART
                                                                                    Incertitude élargie
                                                                                                            Incertitude limite
                                                                                    laboratoire /
                                                                                                            du CISPR / CISPR
Type de mesure / Kind of measurement                                                Wide uncertainty
                                                                                                            uncertainty limit ±
                                                                                    laboratory
                                                                                                            y
                                                                                    (k=2) ± x
Mesure des perturbations conduites en tension sur le réseau d’énergie (monophasé)
                                                                                          3.57 dB                  3.6 dB
Measurement of conducted disturbances in voltage on the power port (single line)
Mesure du champ électrique rayonné sur le site en espace libre de Moirans
                                                                                          5.07 dB                  5.2 dB
Measurement of radiated electric field on the Moirans open area test site
Mesure du champ électrique rayonné IN SITU de 30 à 1000 MHz                             A l’étude /
                                                                                                                   5.2 dB
IN SITU measurement of radiated electric field from 30 to 1000MHz                   Under consideration


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                              Page : 12 / 15


6.     ANNEX 1 (GRAPHS)

                                              CONDUCTED EMISSIONS
Graph name :                Emc#1                         Test configuration:
Limit :                     FCC PART15B                   Phase
Class :                     B
                                                  PARAMETERS
Voltage / Frequency :       230VAC / 50Hz                 Legend:
Line :                      Phase1
                                                               Peak Measure             Average Measure
RBW :                       9kHz
VBW :                       30kHz
                                                               QPeak Limit              Average Limit
Frequency :                 150kHz- 30MHz




               Frequency     Avg    Lim Avg     Avg-LimAvg   QPeak    LimQPeak   QPeak-LimQPeak
                 (MHz)     (dBµV)   (dBµV)        (dBµV)     (dBµV)     (dBµV)       (dBµV)
                 0.438      44.66    46.88         -2.21      49.71      56.88        -7.16
                 0.442      44.55    46.51         -1.96      49.98      56.51        -6.53
                 0.462      42.45    46.00         -3.55      48.87      56.00        -7.13
                 1.322      29.99    46.00        -16.01      36.25      56.00       -19.75
                 2.286      30.88    46.00        -15.12      35.99      56.00       -20.01
                 19.046     41.81    50.00         -8.19      42.06      60.00       -17.94


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                            Page : 13 / 15



                                          CONDUCTED EMISSIONS
Graph name :                Emc#2                     Test configuration:
Limit :                     FCC PART15B               Neutral
Class :                     B
                                              PARAMETERS
Voltage / Frequency :       230VAC / 50Hz             Legend:
Line :                      Phase2
                                                        Peak Measure                  Average Measure
RBW :                       9kHz
VBW :                       30kHz
                                                        QPeak Limit                   Average Limit
Frequency :                 150kHz- 30MHz




               Frequency     Avg    Lim Avg   Avg-LimAvg   QPeak    LimQPeak   QPeak-LimQPeak
                 (MHz)     (dBµV)   (dBµV)      (dBµV)     (dBµV)     (dBµV)       (dBµV)
                 0.318      36.14    49.76      -13.62      44.38      59.76       -15.38
                 0.442      44.34    47.10       -2.76      49.67      57.10        -7.43
                 0.498      41.61    46.03       -4.42      47.25      56.03        -8.78
                 1.370      32.27    46.00      -13.73      37.97      56.00       -18.03
                 2.346      31.77    46.00      -14.23      37.16      56.00       -18.84
                 19.046     42.30    50.00       -7.70      42.52      60.00       -17.48


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                            Page : 14 / 15



                                          RADIATED EMISSIONS
Graph name :                EMR#1                      Test configuration:
Limit :                     FCC Part15B
Class :                     B


                                              PARAMETERS
Antenna polarization:       Horizontale               Legend:
Azimuth :                   0° - 360°
                                                                       Peak Measure
RBW :                       100kHz
VBW :                       300kHz
                                                                       QPeak Limit@3m
Frequency :                 30MHz- 1.001GHz

              100
        dBµV/m




               0
                    30MHz                                                                     1.001GHz
                                                     Fréquence (MHz)




                                   Frequency (MHz)               Peak (dBµV/m)

                                      No frequency has been detected.


RAPPORT D'ESSAI / TEST REPORT N° 249971-R1-E                                             Page : 15 / 15



                                          RADIATED EMISSIONS
Graph name :                EMR#2                      Test configuration:
Limit :                     FCC Part15B
Class :                     B


                                              PARAMETERS
Antenna polarization:       Verticale                 Legend:
Azimuth :                   0° - 360°
                                                                        Peak Measure
RBW :                       100kHz
VBW :                       300kHz
                                                                        QPeak Limit@3m
Frequency :                 30MHz- 1.001GHz

              100
        dBµV/m




               0
                    30MHz                                                                      1.001GHz
                                                      Fréquence (MHz)




                                    Frequency (MHz)               Peak (dBµV/m)
                                         43.80                        27.18
                                         44.96                        27.57
                                         45.56                        27.41
                                         60.32                        22.27



Document Created: 2012-01-31 17:41:58
Document Modified: 2012-01-31 17:41:58

© 2024 FCC.report