Measurement Conditions
   DASY system configuration, as far as not given on page 1.
     DASY Version                                              DASY5                               V52.8.2

     Extrapolation                                   Advanced Extrapolation
     Phantom                                          Modular Flat Phantomn

     Distance Dipole Center — TSL                              10 mm                             with Spacer
     Zoom Scan Resolution                              dx, dy, dz =5 mm
     Frequency                                         2450 MHz + 1 MHz



Head TSL parameters
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
     Nomina!l Head TSL parameters                                 22.0 °C           39.2               1.80 mho/m
     Measured Head TSL parameters                              (22.0 x 0.2) °C   39.9 + 6 %         1.84 mho/m # 6 %

     Head TSL temperature change during test                      <0.5 °C


SAR result with Head TSL

     SAR averaged over 1 em‘ (1 g) of Head TSL                  Condition
     SAR measured                                        250 mW input power                   13.2 mW /g

     SAR for nominal Head TSL parameters                     normalized to 1W        §2.5 mW /g a 17.0 % (k=2)


     SAR averaged over 10 cm‘ (10 g) of Head TSL                 condition
     SAR measured                                        250 mW input power                   6.14 mW /g
     SAR for nominal Head TSL parameters                     normalized to 1 W       24.5 mW /g # 16.5 % (k=2)



Body TSL parameters
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
     Nominal Body TSL parameters                                  22.0 °C           52.7               1.95 mho/m
      Measured Body TSL parameters                             (22.0 £0.2) °C    51.0 + 6 %         2.01 mho/m + 6 %

      Body TSL temperature change during test                     <0.5 °C            «=—                     ~~—


SAR result with Body TSL

     SAR averaged over 1 cm* (1 g) of Body TSL                  Condition
      SAR measured                                       250 mW input power                   12.9 mW /g
     SAR for nominal Body TSL parameters                     normalized to 1W        50.5 mW / g x 17.0 % (k=2)

     SAR averaged over 10 cm‘ (10 g) of Body TSL                 condition
      SAR measured                                       250 mW input power                   6.03 mW / g

     SAR for nominal Body TSL parameters                     normalized to 1W        23.8 mW / g x 16.5 %(k=2)



Certificate No: D2450V2—722_Sep12                     Page 3 of 8
                                                                                                euge ra vravy


Appendix

Antenna Parameters with Head TSL

      Impedance, transformed to feed point                                           52.3 Q + 7.6 jQ
      Return Loss                                                                       —22.2 dB



Antenna Parameters with Body TSL

      Impedance, transformed to feed point                                           48.8 Q + 8.4 jQ
      Return Loss                                                                       —21.3 dB




General Antenna Parameters and Design

      Electrical Delay (one direction)                                                   1.152 ns


After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
"Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still
according to the Standard.
No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
feedpoint may be damaged.


Additional EUT Data

      Manufactured by                                                                    SPEAG

      Manufactured on                                                               October 16, 2002




Certificate No: D2450V2—722_Sep12                         Page 4 of 8                               6uge re vravu


DASY5 Validation Report for Head TSL
                                                                                  Date: 13.09.2012

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 — SN: 722

Communication System: CW; Frequency: 2450 MHz
Medium parameters used: £ = 2450 MHz; a = 1.84 mho/m; & = 39.9; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2007)

DASY32 Configuration:

       Probe: ES3DV3 — SN3205; ConvF(4.45, 4.45, 4.45); Calibrated: 30.12.2011;

       Sensor—Surface: 3mm (Mechanical Surface Detection)

       Electronics: DAEA4 $n601; Calibrated: 27.06.2012

       Phantom: Flat Phantom 5.0 (front); Type: QDOOOP50AA; Serial: 1001

       DASY52 52.8.2(969); SEMCAD X 14.6.6(6824)


Dipole Calibration for Head Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 98.454 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 27.064 mW/g
SAR(I g) = 13.2 mW/g; SAR(10 g) = 6.14 mW/g
Maximum value of SAR (measured) = 16.6 W/kg




                            —6.00

                          d 12.00


                           P—ra.00

                            ~24.00



                            —30.00

                                     0 dB = 16.6 W/kg = 24.40 dB W/kg




Certificate No: D2450V2—722_Sep12                   Page 5 of 8


Impedance Measurement Plot for Head TSL




                                                                    43 Sep 2012    19123145
          CHI sii     1 U oOFS        2 S2.B4d4 o   7.6426 a   495.47 pH          2450.000 obd MHz
                                                eP



          Del

          Ca




          fvg
          16


          H1Ld

          CH2




          Ca




          fv
          16"

          H1d

                    START 2 250.000 coo MHz                                STOP 2 650.000 089 MHz




Certificate No: D2450V2—722_Sep12                     Page 6 of 8                               eugy it vrruy


DASY5 Validation Report for Body TSL
                                                                                        Date: 13.09.2012

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 — SN: 722

Communication System: CW; Frequency: 2450 MHz
Medium parameters used: £ = 2450 MHz; o = 2.01 mho/m; s = 51; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASY5 (IERE/IEC/ANSI €63.19—2007)

DASY52 Configuration:

   *   Probe: ES3DV3 — SN3205; ConvF(4.26, 4.26, 4.26); Calibrated: 30.12.2011;

   e   Sensor—Surface: 3mm (Mechanical Surface Detection)

   «   Electronics: DAE4 Sn601; Calibrated: 27.06.2012

   *   Phantom: Flat Phantom 5.0 (back); Type: QDOOOP50AA; Serial: 1002

   +   DASY52 52.8.2(969); SEMCAD X 14.6.6(6824)


Dipole Calibration for Body Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 94.538 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 26.530 mW/g
SAR(I g) = 12.9 mW/g; SAR(10 g) = 6.03 mW/g
Maximum value of SAR (measured) = 16.8 W/kg




        ~20.00


        —25.00
                   0 dB = 16.8 W/kg = 24.51 dB W/kg




Certificate No: D2450V2—722_Sep12              Page 7 of 8                        ruge ce e ce>


Impedance Measurement Plot for Body TSL




                                                               13 Sep 2012 10123:18
          CHI s1      1 L OFS        R48.765 n     84258 e §547.22 pH      2450.000 D0G MHz
                                                  en —=po.
                                                 l—



          De1

          Ca




          fvg
          16


          H1d

          CH2




          Ca




          fre
          16°

          H1d

                   START 2 250.000 000 MHz                           STOP 2 650.000 00B MHz




Certificate No: D2450V2—722_Sep12                     Page 8 of 8
                                                                                         6uge ry vrauy


Calibration
      .     Laboratory of                                            y>
                                                                & \\_//                                          Schweizerischer Kalibrierdienst
Schmid & Partner                                               iE:\_/E;:                                         Service suisse d‘étalonnage
  Engineering AG                                               2y                                                Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                    2 ///\\\ w                                       Swiss Calibration Service
                                                                 Trlilube®

Accredited by the Swiss Accreditation Service (SAS)                                           Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates

Client       Eurofins                                                                         Certificate No: D5GHzV2—1140_Nov12

|CALIBRATION CERTIFICATE
 Object                               D5GHzV2 — SN: 1140


 Calibration procedure(s)             QA CAL—22.v1
                                      Calibration procedure for dipole validation kits between 3—6 GHz



 Calibration date:                    November 13, 2012




 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                     ID #                      Cal Date (Certificate No.)                           Scheduled Calibration
 Power meter EPM—442A                  GB37480704                O1—Nov—12 (No. 217—01640)                            Oct—13
 Power sensor HP 8481A                 US37292783                O1—Nov—12 (No. 217—01640)                            Oct—13
 Reference 20 dB Attenuator            SN: 5058 (20k)            27—Mar—12 (No. 217—01530)                            Apr—13
 Type—N mismatch combination           SN: 5047.2 / 06327        27—Mar—12 (No. 217—01533)                            Apr—18
 Reference Probe EX8DV4                SN: 3503                  30—Dec—11 (No. EX3—3503_Dec11)                       Dec—12
 DAE4                                  SN: 601                   27—Jun—12 (No. DAE4—601_Jun12)                       Jun—13


 Secondary Standards                   ID #                      Check Date (in house)                                Scheduled Check
 Power sensor HP 8481A                 MY41092317                18—Oct—02 (in house check Oct—11)                    In house check: Oct—13
 RF generator R&S SMT—06               100005                    04—Aug—99 (in house check Oct—11)                    In house check: Oct—13
 Network Analyzer HP 8753E             US37390585 $4206          18—Oct—01 (in house check Oct—12)                    In house check: Oct—13



                                       Name                                   Function                                Signature
 Calibrated by:                        Leif Klysner                           Laboratory Technician                W%



 Approved by:                          Katia Pokovic                          Technical Manager                    /g%



                                                                                                                     Issued: November 13, 2012
 This calibration certificate shall not be reproduced exceptin full without written approvalof the laboratory.


Certificate No: D5GHzV2—1140_Nov12                                  Page 1 of 13


Calibration Laboratory of                                   wuIn%
                                                            S\                       Schweizerischer Kalibrierdienst
        ;                                                   fAXZ
Schmid & Partner                                           ilB\Efl_%R{Q
                                                           &      %
                                                                                     Service suisse d‘étalonnage
  Englneering AG                                               saty                  Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                ’«/,///—\\\\\‘           Swiss Calibration Service
                                                               Tt uis

Accredited by the Swiss Accreditation Service (SAS)                               Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates

Glossary:
TSL                         tissue simulating liquid
ConvF                       sensitivity in TSL / NORM x,.y,z
N/A                         not applicable or not measured

Calibration is Performed According to the Following Standards:
   a) IEC 62209—2, "Evaluation of Human Exposure to Radio Frequency Fields from Handheld
      and Body—Mounted Wireless Communication Devices in the Frequency Range of 30 MHz to
      6 GHz: Human models, Instrumentation, and Procedures"; Part 2: "Procedure to determine
      the Specific Absorption Rate (SAR) for including accessories and multiple transmitters",
      March 2010
   b) Federal Communications Commission Office of Engineering & Technology (FCC OET},
      "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency
      Electromagnetic Fields; Additional Information for Evaluating Compliance of Mobile and
      Portable Devices with FCC Limits for Human Exposure to Radiofrequency Emissions",
      Supplement C (Edition 01—01) to Bulletin 65

Additional Documentation:
    c) DASY4/5 System Handbook

Methods Applied and Interpretation of Parameters:
   e Measurement Conditions: Further details are available from the Validation Report at the end
            of the certificate. All figures stated in the certificate are valid at the frequency indicated.
    e       Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
            point exactly below the center marking of the flat phantom section, with the arms oriented
            parallel to the body axis.
    e       Feed Point Impedance and Return Loss: These parameters are measured with the dipole
            positioned under the liquid filled phantom. The impedance stated is transformed from the
            measurement at the SMA connector to the feed point. The Return Loss ensures low
            reflected power. No uncertainty required.
    e       Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
            No uncertainty required.
            SAR measured: SAR measured at the stated antenna input power.
            SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
            connector.
    e       SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
            nominal SAR result.

 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
 probability of approximately 95%.



Certificate No: D5GHzV2—1140_Nov12                             Page 2 of 13            ruge ns veree


Measurement Conditions
    DASY system configuration, as far as not iven on page 1.
     DASY Version                                              DASY5                               V52.8.3
     Extrapolation                                   Advanced Extrapolation
     Phantom                                       Modular Flat Phantom V5.0
     Distance Dipole Center — TSL                              10 mm                             with Spacer
     Zoom Scan Resolution                         dx, dy = 4.0 mm, dz =1.4 mm        Graded Ratio = 1.4 (Z direction)
                                                       5200 MHz + 1 MHz
     Frequency                                         5500 MHz + 1 MHz
                                                       5800 MHz + 1 MHz



Head TSL parameters at 5200 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
     Nominal Head TSL parameters                                  22.0 °C           36.0               4.66 mho/m

     Measured Head TSL parameters                              (22.0 + 0.2) °C   34.8 + 6 %         4.53 mho/m + 6 %
     Head TSL temperature change during test                      <0.5 °C


SAR result with Head TSL at 5200 MHz

     SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
     SAR measured                                        100 mW input power                     7.99 W/kg
     SAR for nominal Head TSL parameters                     normalized to 1W        79.3 Wikg 19.9 % (k=2)

     SAR averaged over 10 cm* (10 g) of Head TSL                condition
     SAR measured                                        100 mW input power                 2.28 Wikg
     SAR for nominal Head TSL parameters                     normalized to 1W        22.6 Wikg + 19.5 % (k=2)


Head TSL parameters at 5500 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
     Nominal Head TSL parameters                                  22.0 °C           35.6               4.96 mho/m
     Measured Head TSL parameters                              (22.0 + 0.2) °C   34.4 +6 %          4.83 mho/m + 6 %

     Head TSL temperature change during test                      <0.5 °C            ————                    ~———


SAR result with Head TSL at 5500 MHz

     SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
     SAR measured                                        100 mW input power                     8.46 W/kg

     SAR for nominal Head TSL parameters                     normalized to 1W        83.9 W / kg + 19.9 % (k=2)

     SAR averaged over 10 cm* (10 g) of Head TSL                 condition

     SAR measured                                        100 mW input power                  2.40 Wikg
     SAR for nominal Head TSL parameters                     normalized to 1W         23.7 Wikg + 19.5 % (k=2)

Certificate No: D5GHzV2—1140_Nov12                   Page 3 of 13


Head TSL parameters at 5800 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
     Nominal Head TSL parameters                                  22.0 °C           35.9               5.27 mho/m
     Measured Head TSL parameters                              (22.0 + 0.2) °C   34.0 + 6 %         5.15 mho/m + 6 %

     Head TSL temperature change during test                      x05°C


SAR result with Head TSL at 5800 MHz

     SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
     SAR measured                                        100 mW input power                     7.83 W/kg
     SAR for nominal Head TSL parameters                     normalized to 1W        77.6 Wikg + 19.9 % (k=2)

     SAR averaged over 10 cm* (10 g) of Head TSL                 condition
     SAR measured                                        100 mW input power                  2.23 Wikg
     SAR for nominal Head TSL parameters                     normalized to 1W         22.1 Wikg + 19.5 % (k=2)




Certificate No: D5GHzV2—1140_Nov12                    Page 4 of 13                         ruge ve vecve


Body TSL parameters at 5200 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity            Conductivity
     Nominal Body TSL parameters                                  22.0 °C           49.0                  5.30 mho/m
     Measured Body TSL parameters                              (22.0 + 0.2) °C   46.8 + 6 %           5.35 mho/m + 6 %
     Body TSL temperature change during test                      <0.5 °C


SAR result with Body TSL at 5200 MHz

     SAR averaged over 1 cm* (1 g) of Body TSL                  Condition

     SAR measured                                        100 mW input power                     7.42 W/kg
     SAR for nominal Body TSL parameters                     normalized to 1W        73.5 Wikg + 19.9 % (k=2)


     SAR averaged over 10 cm* (10 g) of Body TSL                condition
     SAR measured                                        100 mW input power                  2.08 Wikg
     SAR for nominal Body TSL parameters                     normalized to 1W         20.6 Wikg + 19.5 % (k=2)


Body TSL parameters at 5500 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity            Conductivity
     Nominal Body TSL parameters                                  22.0 °C           48.6                  5.65 mho/m

     Measured Body TSL parameters                              (22.0 + 0.2) °C   46.3 + 6 %           5.73 mho/m + 6 %
     Body TSL temperature change during test                      <0.5 °C


SAR result with Body TSL at 5500 MHz

     SAR averaged over 1 cm* (1 g) of Body TSL                  Condition
     SAR measured                                        100 mW input power                     7.97 Wikg

     SAR for nominal Body TSL parameters                     normalized to 1W         79.0 Wikg + 19.9 % (k=2)

     SAR averaged over 10 cm* (10 g) of Body TSL                 condition

     SAR measured                                        100 mW input power                  2.22 Wikg
     SAR for nominal Body TSL parameters                     normalized to 1W         21.9 Wikg + 19.5 % (k=2)




Certificate No: D5GHzV2—1140_Nov12                    Page 5 of 13                              fgec c s en c e>


Body TSL parameters at 5800 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
     Nominal Body TSL parameters                                  22.0 °C           48.2               6.00 mho/m

     Measured Body TSL parameters                              (22.0 + 0.2) °C   45.9 +6 %          6.13 mho/m + 6 %
     Body TSL temperature change during test                      <0.5 °C


SAR result with Body TSL at 5800 MHz

     SAR averaged over 1 cm* (1 g) of Body TSL                  Condition
     SAR measured                                        100 mW input power                     743 W/kg

     SAR for nominal Body TSL parameters                     normalized to 1W        73.6 Wikg + 19.9 % (k=2)

     SAR averaged over 10 cm* (10 g) of Body TSL                 condition
     SAR measured                                        100 mW input power                     2.07 Wikg
     SAR for nominal Body TSL parameters                     normalized to 1W         20.4 Wikg + 19.5 % (k=2)




Certificate No: D5GHzV2—1140_Nov12                    Page 6 of 13                         ruge ce vece>


Appendix

Antenna Parameters with Head TSL at 5200 MHz

      Impedance, transformed to feed point                                           48.6 Q — 7.5 jQ
      Return Loss                                                                       —22.2 dB


Antenna Parameters with Head TSL at 5500 MHz

      Impedance, transformed to feed point                                           53.3 Q — 0.6 jQ

      Return Loss                                                                       —29.8 dB


Antenna Parameters with Head TSL at 5800 MHz

      Impedance, transformed to feed point                                           56.6 Q — 1.8 jQ
      Return Loss                                                                       —23.8 dB


Antenna Parameters with Body TSL at 5200 MHz

      Impedance, transformed to feed point                                           48.6 Q — 6.9 jQ
      Return Loss                                                                       — 22.9 dB


Antenna Parameters with Body TSL at 5500 MHz

      Impedance, transformed to feed point                                           54.2 Q + 0.6 jQ
      Return Loss                                                                       —27.7 dB


Antenna Parameters with Body TSL at 5800 MHz

      Impedance, transformed to feed point                                           57.4 Q — 1.2 jQ
      Return Loss                                                                       —23.1 dB



General Antenna Parameters and Design

      Electrical Delay (one direction)                                                   1.202 ns

After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
"Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still
according to the Standard.
No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
feedpoint may be damaged.

Additional EUT Data

      Manufactured by                                                                    SPEAG

      Manufactured on                                                                 May 07, 2012



Certificate No: D5GHzV2—1140_Nov12                       Page 7 of 13                           uge ce vekee


DASY5 Validation Report for Head TSL
                                                                                         Date: 13.11.2012

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 5GHz; Type: DSGHzV2; Serial: D5GHzV2 — SN: 1140

Communication System: CW; Frequency: 5200 MHz, Frequency: 5500 MHz, Frequency: 5800 MHz
Medium parameters used: f = 5200 MHz; 0 = 4.53 mho/m; &, = 34.8; p = 1000 kg/m3 , Medium parameters
used: £= 5500 MHz; 0 = 4.83 mho/m; &= 34.4; p = 1000 kg/m3 , Medium parameters used: f = 5800 MHz;
o = 5.15 mho/m; &, = 34; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI €63.19—2007)

DASY52 Configuration:

   e   Probe: EX3DV4 — SN3503; ConvF(5.41, 5.41, 5.41); Calibrated: 30.12.2011, ConvF(4.91, 4.91,
       4.91); Calibrated: 30.12.2011, ConvF(4.81, 4.81, 4.81); Calibrated: 30.12.2011;

   e   Sensor—Surface: 1.4mm (Mechanical Surface Detection)

   e   Electronics: DAE4 Sn601; Calibrated: 27.06.2012

   e   Phantom: Flat Phantom 5.0 (front); Type: QDOOOP5OAA; Serial: 1001

   e   DASY52 52.8.3(988); SEMCAD X 14.6.7(6848)


Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5200 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 62.376 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 29.2 W/kg
SAR(1 g) = 7.99 W/kg; SAR(10 g) = 2.28 W/kg
Maximum value of SAR (measured) = 18.0 W/kg

Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5500 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 62.330 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 33.1 W/kg
SAR(1 g) = 8.46 W/kg; SAR(10 g) = 2.4 W/kg
Maximum value of SAR (measured) = 19.7 W/kg


Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5800 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 59.000 V/m; PowerDrift = 0.04 dB
Peak SAR (extrapolated) = 32.2 W/kg
SAR(I g) = 7.83 W/kg; SAR(10 g) = 2.23 W/kg
Maximum value of SAR (measured) = 18.6 W/kg




Certificate No: D5GHzV2—1140_Nov12            Page 8 of 13                      mgec c   en c e>


                      —10.00




                      —20.00




                      —30.00




                      ~40.00




                      50.00
                               0 dB = 18.6 W/ikg = 12.70 dBW/kg




Certificate No: D5GHzV2—1140_Nov12               Page 9 of 13     ruge se ves


Impedance Measurement Plot for Head TSL




                                                                13 Nov 2012       10:59:50
          CHI sii     1 U FS          1: 48.566 a    5371 a   4.0608 pF         5 200.000 000 MHz


          *
                                                                                                        CH1 Markers
          D
              el                                                                                         3: 53.297 a
                                                                                                         ~625.00 m
          Cor                                                                                           5.50000 GHz
                                                                                                         5t 56,637 a
                                                                                                           —1.8105 a
                                                                                                        5.90000 GHz


          Av
          189



          H1d

          CH2



                                                                                                        CH2 Markers

                                                                                                        3:—29.765 dB
          tor                                                                                           5.50000 GHz
                                                                                                        5:—23.802 dB
                                                                                                         5.90000 GHz


          Av
          169


          H1d

                    START 5 000.000 900 MHz                               STOP 6 000.000 000 MHz




Certificate No: D5GHzV2—1140_Nov12                  Page 10 of 13                              mgec co en c e>


DASY5 Validation Report for Body TSL

                                                                                             Date: 12.11.2012

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 5GHz; Type: D5GHzV2; Serial: D5SGHzV2 — SN: 1140

Communication System: CW; Frequency: 5200 MHz, Frequency: 5500 MHz, Frequency: 5800 MHz
Medium parameters used: £ = 5200 MHz; 0 = 5.35 mho/m; &, = 46.8; p = 1000 kg/m* , Medium parameters
used: £= 5500 MHz; o = 5.73 mho/m; &, = 46.3; p = 1000 kg/m3 , Medium parameters used: £ = 5800 MHz;
0 = 6.13 mho/m; & = 45.9; p = 1000 kg/m>*
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2007)

DASY52 Configuration:

   e   Probe: EX3DV4 — SN3503; ConvF(4.91, 4.91, 4.91); Calibrated: 30.12.2011, ConvF(4.43, 4.43,
       4.43); Calibrated: 30.12.2011, ConvF(4.38, 4.38, 4.38); Calibrated: 30.12.2011;

   e    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

   e   Electronics: DAE4 Sn601; Calibrated: 27.06.2012

   e   Phantom: Flat Phantom 5.0 (back); Type: QDOOOPS50AA; Serial: 1002

       DASY52 52.8.3(988); SEMCAD X 14.6.7(6848)


Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5200 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 58.434 V/m; Power Drift =—0.01 dB
Peak SAR (extrapolated) = 29.5 W/kg
SAR(1 g) =7.42 W/kg; SAR(10 g) = 2.08 W/kg
Maximum value of SAR (measured) = 17.7 W/kg


Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5500 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 59.004 V/m; Power Drift =—0.01 dB
Peak SAR (extrapolated) = 34.8 W/kg
SAR(1 g) =7.97 W/kg; SAR(10 g) = 2.22 W/kg
Maximum value of SAR (measured) = 19.8 W/kg


Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5800 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 54.978 V/m; Power Drift =—0.01 dB
Peak SAR (extrapolated) = 34.8 W/kg
SAR(I g) =7.43 W/kg; SAR(10 g) = 2.07 W/kg
Maximum value of SAR (measured) = 18.7 W/kg




Certificate No: D5GHzV2—1140_Nov12             Page 11 of 13                        mgec c   en c e>


                       —10.00




                       —20.00




                       ~30.00




                       ~40.00




                       —50.00

                                0 dB = 18.7 W/kg = 12.72 dBW/kg




Certificate No: D5GHzV2—1140_Nov12               Page 12 of 13    noge > <n >


Impedance Measurement Plot for Body TSL




                                                                12 Nov 2012      12:58:03
         CHI] s11     1 U OFS         1:48.553 a   —6,8984n   4.4360 pF         5 200.000 000 MHz


         *
                                                                                                       CH1 Markers
         Del
                                                                                                         3: 54.248 a
                                                                                                            0.5977 a
         Cor                                                                                            5.50000 GHz
                                                                                                         5: 57.432 a
                                                                                                           ~1.1836 a
                                                                                                        5.90000 GHz


         Av
         169


         H1d

          CH2




                                                                                                        CH2 Markers

                                                                                                        3—27,712 dB
         tor                                                                                            5.50000 GHz
                                                                                                        5:—23.093 dB
                                                                                                         5.80000 GHz


         Av
         16"

         H1d

                    START 5 000.000 000 MHz                               STOP 6 000.000 000 MHz




Certificate No: D5GHzV2—1140_Nov12                  Page 13 of 13                              mgec cn en c e>


ANNEX B   System Validation Reports




                 Test Report No.: G0M-1212-2506-TFC093S-V01
                               Eurofins Product Service GmbH
                 Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                     Page 90 of 103


                                                                       Date/Time: 10.01.2013 07:29:40

Test Laboratory: Eurofins Product Service GmbH


Dipol Valid.2450 (m)_250mW 10.01.2013

DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 722

Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: Muscle 2450 MHz Medium parameters used: f = 2450 MHz; σ = 2.002 mho/m; εr = 52.935; ρ = 1000
kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

      Probe: ET3DV6 - SN1711; ConvF(4.07, 4.07, 4.07); Calibrated: 19.09.2012;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE3 Sn522; Calibrated: 13.09.2012
      Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
      Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6824)


System Performance Check at Frequencies above 1 GHz/d=10mm, Pin=250 mW, dist=4.0mm
(ET-Probe)/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 12.5 W/kg

System Performance Check at Frequencies above 1 GHz/d=10mm, Pin=250 mW, dist=4.0mm
(ET-Probe)/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 78.785 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 33.623 mW/g
SAR(1 g) = 12.8 mW/g; SAR(10 g) = 5.77 mW/g
Maximum value of SAR (measured) = 13.8 W/kg




                                                                                   Page 91 of 103


                                                                       Date/Time: 14.01.2013 09:15:49

Test Laboratory: Eurofins Product Service GmbH


Dipol Valid.5200 (m)_100mW 14.01.2013

DUT: Dipole D5GHzV2; Type: D5GHzV2; Serial: D5GHzV2 - SN1140

Communication System: CW; Frequency: 5200 MHz;Duty Cycle: 1:1
Medium: MBBL 3-6 GHz Medium parameters used: f = 5200 MHz; σ = 5.474 mho/m; εr = 49.147; ρ = 1000
kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

      Probe: EX3DV4 - SN3893; ConvF(4.33, 4.33, 4.33); Calibrated: 26.11.2012;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE3 Sn522; Calibrated: 13.09.2012
      Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
      Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6824)


System Performance Check at Frequencies above 1 GHz/d=10mm, Pin=100 mW, dist=2.0mm
(EX-Probe)/Area Scan (7x13x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 6.66 W/kg

System Performance Check at Frequencies above 1 GHz/d=10mm, Pin=100 mW, dist=2.0mm
(EX-Probe)/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 36.535 V/m; Power Drift = -0.04 dB
Peak SAR (extrapolated) = 38.734 mW/g
SAR(1 g) = 7.47 mW/g; SAR(10 g) = 2.02 mW/g
Maximum value of SAR (measured) = 7.54 W/kg




                                                                                   Page 92 of 103


                                                                       Date/Time: 12.07.2013 14:39:23

Test Laboratory: Eurofins Product Service GmbH


Dipol Valid.5500 (m)_100mW 12.07.2013

DUT: Dipole D5GHzV2; Type: D5GHzV2; Serial: D5GHzV2 - SN1140

Communication System: UID 0 - n/a, CW; Frequency: 5500 MHz;Duty Cycle: 1:1
Medium: MBBL 3-6 GHz Medium parameters used: f =5500MHz; σ = 5.86 S/m; εr = 48.9; ρ = 1000 kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

     Probe: EX3DV4 - SN3893; ConvF(4.33, 4.33, 4.33); Calibrated: 26.11.2012;
     Sensor-Surface: 4mm (Mechanical Surface Detection)
     Electronics: DAE3 Sn522; Calibrated: 13.09.2012
     Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
     Measurement SW: DASY52, Version 52.8 (6); SEMCAD X Version 14.6.9 (7117)


System Performance Check at Frequencies above 1 GHz/d=10mm, Pin=100 mW, dist=2.0mm
(EX-Probe)/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 8.14 W/kg

System Performance Check at Frequencies above 1 GHz/d=10mm, Pin=100 mW, dist=2.0mm
(EX-Probe)/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 39.990 V/m; Power Drift = -0.04 dB
Peak SAR (extrapolated) = 50.6 W/kg
SAR(1 g) = 8.67 W/kg; SAR(10 g) = 2.3 W/kg
Maximum value of SAR (measured) = 8.25 W/kg




                 0 dB = 8.14 W/kg = 9.11 dBW/kg


                                                                                   Page 93 of 103


                                                                       Date/Time: 11.07.2013 10:15:14

Test Laboratory: Eurofins Product Service GmbH


Dipol Valid.5800 (m)_100mW 11.07.2013

DUT: Dipole D5GHzV2; Type: D5GHzV2; Serial: D5GHzV2 - SN1140

Communication System: UID 0 - n/a, CW; Frequency: 5800 MHz;Duty Cycle: 1:1
Medium: MBBL 3-6 GHz Medium parameters used: f = 5800 MHz; σ = 6.29 S/m; εr = 48.4; ρ = 1000 kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

     Probe: EX3DV4 - SN3893; ConvF(4.08, 4.08, 4.08); Calibrated: 26.11.2012;
     Sensor-Surface: 4mm (Mechanical Surface Detection)
     Electronics: DAE3 Sn522; Calibrated: 13.09.2012
     Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
     Measurement SW: DASY52, Version 52.8 (6); SEMCAD X Version 14.6.9 (7117)


System Performance Check at Frequencies above 1 GHz/d=10mm, Pin=100 mW, dist=2.0mm
(EX-Probe)/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 8.31 W/kg

System Performance Check at Frequencies above 1 GHz/d=10mm, Pin=100 mW, dist=2.0mm
(EX-Probe)/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 37.029 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 66.8 W/kg
SAR(1 g) = 8.04W/kg; SAR(10 g) = 2.2 W/kg
Maximum value of SAR (measured) = 8.61 W/kg




                 0 dB = 8.31 W/kg = 9.20 dBW/kg


                                                                                   Page 94 of 103


ANNEX C   SAR Measurement Reports




                Test Report No.: G0M-1212-2506-TFC093S-V01
                              Eurofins Product Service GmbH
                Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                    Page 95 of 103


                                                                         Date/Time: 10.01.2013 08:04:35

Test Laboratory: Eurofins Product Service GmbH


WLAN-2.4G_CH-6_DSSS_1MBit_Flat_Front_0mm

DUT: i.roc Ci70; Type: PDA with WLAN 2.4G/5G; Serial: Sample1

Communication System: WLAN 2.4G / 5G FCC; Frequency: 2437 MHz;Duty Cycle: 1:1
Medium: Muscle 2450 MHz Medium parameters used: f = 2437 MHz; σ = 2.003 mho/m; εr = 52.932; ρ = 1000
kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

      Probe: ET3DV6 - SN1711; ConvF(4.07, 4.07, 4.07); Calibrated: 19.09.2012;
      Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Sensor-Surface: 4mm (Mechanical
      Surface Detection)
      Electronics: DAE3 Sn522; Calibrated: 13.09.2012
      Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
      Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6824)


Configuration/i.roc Ci70/Area Scan (7x15x1): Measurement grid: dx=20mm, dy=20mm
Maximum value of SAR (measured) = 0.0925 W/kg

Configuration/i.roc Ci70/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 2.748 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 0.230 mW/g
SAR(1 g) = 0.098 mW/g; SAR(10 g) = 0.053 mW/g
Maximum value of SAR (measured) = 0.101 W/kg




                                                                                     Page 96 of 103


                                                                         Date/Time: 10.01.2013 08:36:43

Test Laboratory: Eurofins Product Service GmbH


WLAN-2.4G_CH-6_DSSS_1MBit_Flat_Back_0mm

DUT: i.roc Ci70; Type: PDA with WLAN 2.4G/5G; Serial: Sample1

Communication System: WLAN 2.4G / 5G FCC; Frequency: 2437 MHz;Duty Cycle: 1:1
Medium: Muscle 2450 MHz Medium parameters used: f = 2437 MHz; σ = 2.003 mho/m; εr = 52.932; ρ = 1000
kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

      Probe: ET3DV6 - SN1711; ConvF(4.07, 4.07, 4.07); Calibrated: 19.09.2012;
      Sensor-Surface: 4mm (Mechanical And Optical Surface Detection), Sensor-Surface: 4mm (Mechanical
      Surface Detection)
      Electronics: DAE3 Sn522; Calibrated: 13.09.2012
      Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
      Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6824)


Configuration/i.roc Ci70/Area Scan (7x15x1): Measurement grid: dx=20mm, dy=20mm
Maximum value of SAR (measured) = 0.116 W/kg

Configuration/i.roc Ci70/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 4.142 V/m; Power Drift = -0.16 dB
Peak SAR (extrapolated) = 0.302 mW/g
SAR(1 g) = 0.134 mW/g; SAR(10 g) = 0.076 mW/g
Maximum value of SAR (measured) = 0.138 W/kg




                                                                                     Page 97 of 103


                                                                       Date/Time: 14.01.2013 10:41:41

Test Laboratory: Eurofins Product Service GmbH


WLAN-5G-U-NII-Lower_CH-48_OFDM_6MBit_Flat_Back_0mm

DUT: i.roc Ci70; Type: PDA with WLAN 2.4G/5G; Serial: Sample1

Communication System: WLAN 2.4G / 5G FCC; Frequency: 5240 MHz;Duty Cycle: 1:1
Medium: MBBL 3-6 GHz Medium parameters used (interpolated): f = 5240 MHz; σ = 5.513 mho/m; εr =
49.068; ρ = 1000 kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

      Probe: EX3DV4 - SN3893; ConvF(4.33, 4.33, 4.33); Calibrated: 26.11.2012;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE3 Sn522; Calibrated: 13.09.2012
      Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
      Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6824)


Configuration/i.roc Ci70/Area Scan (7x15x1): Measurement grid: dx=20mm, dy=20mm
Maximum value of SAR (measured) = 0.219 W/kg

Configuration/i.roc Ci70/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 1.362 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 0.771 mW/g
SAR(1 g) = 0.260 mW/g; SAR(10 g) = 0.105 mW/g
Maximum value of SAR (measured) = 0.289 W/kg




                                                                                   Page 98 of 103


                                                                       Date/Time: 14.01.2013 11:54:12

Test Laboratory: Eurofins Product Service GmbH


WLAN-5G-U-NII-middle_CH-64_OFDM_6MBit_Flat_Back_0mm

DUT: i.roc Ci70; Type: PDA with WLAN 2.4G/5G; Serial: Sample1

Communication System: WLAN 2.4G / 5G FCC; Frequency: 5320 MHz;Duty Cycle: 1:1
Medium: MBBL 3-6 GHz Medium parameters used: f = 5320 MHz; σ = 5.563 mho/m; εr = 48.964; ρ = 1000
kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

      Probe: EX3DV4 - SN3893; ConvF(4.33, 4.33, 4.33); Calibrated: 26.11.2012;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE3 Sn522; Calibrated: 13.09.2012
      Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
      Measurement SW: DASY52, Version 52.8 (2); SEMCAD X Version 14.6.6 (6824)


Configuration/i.roc Ci70/Area Scan (7x15x1): Measurement grid: dx=20mm, dy=20mm
Maximum value of SAR (measured) = 0.260 W/kg

Configuration/i.roc Ci70/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 1.036 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 0.888 mW/g
SAR(1 g) = 0.334 mW/g; SAR(10 g) = 0.130 mW/g
Maximum value of SAR (measured) = 0.388 W/kg




                                                                                   Page 99 of 103


                                                                       Date/Time: 12.07.2013 13:10:06

Test Laboratory: Eurofins Product Service GmbH


WLAN-5G-U-NII-CH-100_OFDM_6MBit_Flat_front 2_0mm

DUT: i.roc Ci70; Type: PDA with WLAN 2.4G/5G; Serial: Sample1

Communication System: UID 0 - n/a, IEEE 802.11a/h WiFi 5 GHz (OFDM, 6Mbps); Frequency: 5500
MHz;Duty Cycle: 1:17.0608
Medium: MBBL 3-6 GHz Medium parameters used: f = 5500 MHz; σ = 5.86 S/m; εr = 48.9; ρ = 1000 kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

     Probe: EX3DV4 - SN3893; ConvF(4.1, 4.1, 4.1); Calibrated: 26.11.2012;
     Sensor-Surface: 4mm (Mechanical Surface Detection)
     Electronics: DAE3 Sn522; Calibrated: 13.09.2012
     Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
     Measurement SW: DASY52, Version 52.8 (6); SEMCAD X Version 14.6.9 (7117)


Configuration/i.roc Ci70/Area Scan (8x9x1): Measurement grid: dx=20mm, dy=20mm
Maximum value of SAR (measured) = 0.0245 W/kg

Configuration/i.roc Ci70/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 1.047 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.0150 W/kg
SAR(1 g) = 0.000211 W/kg; SAR(10 g) = 2.26e-005 W/kg

Maximum value of SAR (measured) = 0.0151 W/kg




                                                                                  Page 100 of 103


                                                                       Date/Time: 12.07.2013 13:32:10

Test Laboratory: Eurofins Product Service GmbH


WLAN-5G-U-NII-CH-100_OFDM_6MBit_Flat_back_0mm

DUT: i.roc Ci70; Type: PDA with WLAN 2.4G/5G; Serial: Sample1

Communication System: UID 0 - n/a, IEEE 802.11a/h WiFi 5 GHz (OFDM, 6Mbps); Frequency: 5500
MHz;Duty Cycle: 1:17.0608
Medium: MBBL 3-6 GHz Medium parameters used: f = 5500 MHz; σ = 5.86 S/m; εr = 48.9; ρ = 1000 kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

     Probe: EX3DV4 - SN3893; ConvF(4.1, 4.1, 4.1); Calibrated: 26.11.2012;
     Sensor-Surface: 4mm (Mechanical Surface Detection)
     Electronics: DAE3 Sn522; Calibrated: 13.09.2012
     Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
     Measurement SW: DASY52, Version 52.8 (6); SEMCAD X Version 14.6.9 (7117)


Configuration/i.roc Ci70/Area Scan (8x14x1): Measurement grid: dx=20mm, dy=20mm
Maximum value of SAR (measured) = 0.107 W/kg

Configuration/i.roc Ci70/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 0 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 0.487 W/kg
SAR(1 g) = 0.101 W/kg; SAR(10 g) = 0.038 W/kg

Maximum value of SAR (measured) = 0.0849 W/kg




                                                                                  Page 101 of 103


                                                                         Date/Time: 11.07.2013 09:31:52

Test Laboratory: Eurofins Product Service GmbH


WLAN-5G-U-NII-CH-149_OFDM_6MBit_Flat_front 2_0mm

DUT: i.roc Ci70; Type: PDA with WLAN 2.4G/5G; Serial: Sample1

Communication System: UID 0 - n/a, IEEE 802.11a/h WiFi 5 GHz (OFDM, 6Mbps); Frequency: 5745
MHz;Duty Cycle: 1:17.0608
Medium: MBBL 3-6 GHz Medium parameters used (interpolated): f = 5745 MHz; σ = 6.221 S/m; εr = 48.41; ρ
= 1000 kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

      Probe: EX3DV4 - SN3893; ConvF(4.08, 4.08, 4.08); Calibrated: 26.11.2012;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE3 Sn522; Calibrated: 13.09.2012
      Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
      Measurement SW: DASY52, Version 52.8 (6); SEMCAD X Version 14.6.9 (7117)


Configuration/i.roc Ci70/Area Scan (7x15x1): Measurement grid: dx=20mm, dy=20mm
Maximum value of SAR (measured) = 0.0289 W/kg

Configuration/i.roc Ci70/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 0.781 V/m; Power Drift = 0.1dB
Peak SAR (extrapolated) = 0.0190 W/kg
SAR(1 g) = 0.000296 W/kg; SAR(10 g) = 6.52e-005 W/kg

Maximum value of SAR (measured) = 0.0187 W/kg




                                                                                    Page 102 of 103


                                                                         Date/Time: 11.07.2013 07:25:45

Test Laboratory: Eurofins Product Service GmbH


WLAN-5G-U-NII-CH-149_OFDM_6MBit_Flat_back_0mm

DUT: i.roc Ci70; Type: PDA with WLAN 2.4G/5G; Serial: Sample1

Communication System: UID 0 - n/a, IEEE 802.11a/h WiFi 5 GHz (OFDM, 6Mbps); Frequency: 5745
MHz;Duty Cycle: 1:17.0608
Medium: MBBL 3-6 GHz Medium parameters used (interpolated): f = 5745 MHz; σ = 6.221 S/m; εr = 48.41; ρ
= 1000 kg/m3
Phantom section: Flat Section

Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-2007)

DASY5.2 Configuration:

      Probe: EX3DV4 - SN3893; ConvF(4.08, 4.08, 4.08); Calibrated: 26.11.2012;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE3 Sn522; Calibrated: 13.09.2012
      Phantom: ELI v4.0; Type: QDOVA001BB; Serial: TP: 1013
      Measurement SW: DASY52, Version 52.8 (6); SEMCAD X Version 14.6.9 (7117)


Configuration/i.roc Ci70/Area Scan (7x15x1): Measurement grid: dx=20mm, dy=20mm
Maximum value of SAR (measured) = 0.0556 W/kg

Configuration/i.roc Ci70/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 2.043 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 0.148 W/kg
SAR(1 g) = 0.019 W/kg; SAR(10 g) = 0.00542 W/kg

Maximum value of SAR (measured) = 0.0363 W/kg




                                                                                    Page 103 of 103