Test Report

FCC ID: WQJ-KIOSKIII

Test Report

Download: PDF
FCCID_2612142

                                                                 Report No.: C150205Z03-RP1




                        FCC 47 CFR PART 15 SUBPART C
                             TEST REPORT
                                             for

                                      ViVOpay Kiosk III
                                  MODEL: ViVOpay Kiosk III
                                       Brand: ViVOpay
                                    Test Report Number:
                                      C150205Z03-RP1

                                          Issued for

                                          ID TECH
                        10721 Walker Street, Cypress, California 90630

                                          Issued by:

                   Compliance Certification Services (Shenzhen) Inc.
           No.10-1, Mingkeda Logistics Park, NO.18, Huanguan South Rd.,
                  Guan Lan Town, Baoan District, Shenzhen, China
                                    TEL: 86-755-28055000
                                    FAX: 86-755-28055221
                                 Issued Date: March 24, 2015




                                                                 检 测
                                                               CNAS L4818

Note: This report shall not be reproduced except in full, without the written approval of
Compliance Certification Services Inc. This document may be altered or revised by
Compliance Certification Services Inc. personnel only, and shall be noted in the revision
section of the document. The client should not use it to claim product endorsement by TAF,
A2LA, NVLAP, NIST or any government agencies. The test results in the report only apply
to the tested sample.




FCC ID : WQJ-KIOSKIII                                                             Page 1 / 26


                                                                                    Report No.: C150205Z03-RP1

                                             Revision History

                                                                                    Effect
                Issue Date
 Rev.                                                Revisions                      Page        Revised By
  00         March 24, 2015                         Initial Issue                    ALL         Nancy Fu




FCC ID : WQJ-KIOSKIII                                                                                      Page 2 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                     Report No.: C150205Z03-RP1


                                 TABLE OF CONTENTS
1 TEST CERTIFICATION ................................................................................................. 4
2 EUT DESCRIPTION....................................................................................................... 5
3 TEST METHODOLOGY................................................................................................. 6
   3.1. DESCRIPTION OF TEST MODES ...................................................................................... 6
4 TEST METHODOLOGY................................................................................................. 7
   4.1.   EUT CONFIGURATION ....................................................................................................... 7
   4.2.   EUT EXERCISE...................................................................................................................7
   4.3.   GENERAL TEST PROCEDURES ....................................................................................... 7
   4.4.   FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS ........................................... 8
5 INSTRUMENT CALIBRATION ...................................................................................... 9
6 SETUP OF EQUIPMENT UNDER TEST ....................................................................... 9
   6.1. DESCRIPTION OF SUPPORT UNITS................................................................................. 9
   6.2. CONFIGURATION OF SYSTEM UNDER TEST ................................................................. 9
7 FACILITIES AND ACCREDITATIONS ........................................................................ 10
   7.1. FACILITIES ........................................................................................................................ 10
   7.2. ACCREDITATIONS ........................................................................................................... 10
   7.3. MEASUREMENT UNCERTAINTY..................................................................................... 10
8 FCC PART 15.225 REQUIREMENTS ......................................................................... 11
   8.1.   TIMING OF THE TRANSMITTER ...................................................................................... 11
   8.2.   99 % EMISSION BANDWIDTH.......................................................................................... 12
   8.3.   POWER LINE CONDUCTED EMISSIONS MEASUREMENT........................................... 14
   8.4.   SPURIOUS EMISSIONS MEASUREMENT....................................................................... 19
   8.5.   FREQUENCY STABILITY.................................................................................................. 25




FCC ID : WQJ-KIOSKIII                                                                                      Page 3 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

1     TEST CERTIFICATION
    Product          ViVOpay Kiosk III

    Model            ViVOpay Kiosk III

    Brand            ViVOpay

    Tested           February 5~ March 24, 2015
                     ID TECH
    Applicant
                     10721 Walker Street, Cypress, California 90630
                     ID TECH
    Manufacturer
                     10721 Walker Street, Cypress, California 90630


                                         APPLICABLE STANDARDS
                       STANDARD                                                 TEST RESULT
              FCC 47 CFR Part 15 Subpart C                                 No non-compliance noted
                             DEVIATION FROM APPLICABLE STANDARD
                                                         None

We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data,
data evaluation, test procedures, and equipment configurations shown in this report were
made in accordance with the procedures given in ANSI C63.10: 2013 and the energy
emitted by the sample EUT tested as described in this report is in compliance with the
requirements of FCC Rules Part 15.225.

The test results of this report relate only to the tested sample EUT identified in this report.



Approved by:                                                  Reviewed by:




Sunday Hu                                                     Ruby Zhang
Supervisor of EMC Dept.                                       Supervisor of Report Dept.
Compliance Certification Service Inc.                         Compliance Certification Service Inc.




FCC ID : WQJ-KIOSKIII                                                                                      Page 4 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

2    EUT DESCRIPTION
 Product                                  ViVOpay Kiosk III
 Model Number                             ViVOpay Kiosk III
 Brand                                    ViVOpay
 Model Discrepancy                        N/A
 Identify Number                          C150205Z03-RP1
 Received Date                           February 5, 2015

 Power Supply                            DC7.5V supplied by the adapter
                                         DVE / DSA-12PFA-05 FUS 075100
 Adapter Manufacturer /                  I/P: AC100-240V, 50/60Hz, 0.5A
 Model No.                               O/P: DC7.5V, 1A
                                         DC Output Cable: Unshielded, 1.80m(with a core)
 Frequency Range                          13.56 MHz
 Transmit Power                           63.94dBuV/m(measured at 3m)
 Modulation Technique                     ASK
 Number of Channels                       1Channel
 Antenna Specification                   PCB antenna with 0dBi gain (Max)
 Temperature Range                        5°C ~ +50°C
 Hardware Version                         80136110
 Software Version                         80136120

Note: 1. The sample selected for test was engineering sample that approximated to production product and
        was provided by manufacturer.

      2. This submittal(s) (test report) is intended for FCC ID: WQJ-KIOSKIII filing to comply with Section
        15.225 of the FCC Part 15, Subpart C Rules.




FCC ID : WQJ-KIOSKIII                                                                                      Page 5 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

3    TEST METHODOLOGY
3.1. DESCRIPTION OF TEST MODES
The EUT had been tested under operating condition.
After verification, all tests were carried out with the worst case test modes as shown below
except radiated spurious emission below 1GHz, which worst case was in normal
link(powered by the adapter) mode only, and powerline conducted emission below 30MHz,
which worst case was in normal link mode with charging only.
Channel 1 (13.56MHz) was chosen for the final testing.




FCC ID : WQJ-KIOSKIII                                                                                      Page 6 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

4    TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.10: 2013
and FCC CFR 47 15.207, 15.209 and 15.225.

4.1. EUT CONFIGURATION
The EUT configuration for testing is installed on RF field strength measurement to meet the
Commissions requirement and operating in a manner that intends to maximize its emission
characteristics in a continuous normal application.

4.2. EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the
purpose of the measurements.
According to its specifications, the EUT must comply with the requirements of the Section
15.207, 15.209, 15.225 under the FCC Rules Part 15 Subpart C.

4.3. GENERAL TEST PROCEDURES
Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
requirements in Section 13.1.4.1 of ANSI C63.10: 2013. Conducted emissions from the
EUT
measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak
and average detector modes.
Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall
rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m
away from the receiving antenna, which varied from 1m to 4m to find out the highest
emission. And also, each emission was to be maximized by changing the polarization of
receiving antenna both horizontal and vertical. In order to find out the maximum emissions,
exploratory radiated emission measurements were made according to the requirements in
Section 13.1.4.1 of ANSI C63.10: 2013.




FCC ID : WQJ-KIOSKIII                                                                                      Page 7 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

4.4. FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
    (a) Except as shown in paragraph (d) of this section, only spurious emissions are
     permitted in any of the frequency bands listed below:
                MHz                          MHz                        MHz                    GHz

            0.090 - 0.110      16.42 - 16.423     399.9 - 410                              4.5 - 5.15
           1
            0.495 - 0.505   16.69475 - 16.69525    608 - 614                              5.35 - 5.46
          2.1735 - 2.1905   16.80425 - 16.80475   960 - 1240                              7.25 - 7.75
           4.125 - 4.128         25.5 - 25.67     1300 - 1427                             8.025 - 8.5
         4.17725 - 4.17775       37.5 - 38.25    1435 - 1626.5                              9.0 - 9.2
         4.20725 - 4.20775         73 - 74.6    1645.5 - 1646.5                             9.3 - 9.5
           6.215 - 6.218         74.8 - 75.2      1660 - 1710                             10.6 - 12.7
         6.26775 - 6.26825      108 - 121.94    1718.8 - 1722.2                           13.25 - 13.4
         6.31175 - 6.31225        123 - 138       2200 - 2300                             14.47 - 14.5
           8.291 - 8.294       149.9 - 150.05     2310 - 2390                             15.35 - 16.2
           8.362 - 8.366        156.52475 -      2483.5 - 2500                            17.7 - 21.4
         8.37625 - 8.38675        156.52525       2655 - 2900                            22.01 - 23.12
         8.41425 - 8.41475      156.7 - 156.9     3260 - 3267                             23.6 - 24.0
           12.29 - 12.293    162.0125 - 167.17    3332 - 3339                             31.2 - 31.8
        12.51975 - 12.52025    167.72 - 173.2    3345.8 - 3358                            36.43 - 36.5
        12.57675 - 12.57725       240 - 285       3600 - 4400                                   ( 2)
           13.36 - 13.41         322 - 335.4
    1
        Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
    2
        Above 38.6
  (b) Except as provided in paragraphs (d) and (e), the field strength of emissions
    appearing within these frequency bands shall not exceed the limits shown in Section
    15.209. At frequencies equal to or less than 1000 MHz, compliance with the limits in
    Section 15.209 shall be demonstrated using measurement instrumentation employing
    a CISPR quasi-peak detector. Above 1000 MHz, compliance with the emission limits in
    Section 15.209 shall be demonstrated based on the average value of the measured
    emissions. The provisions in Section 15.35 apply to these measurements.




FCC ID : WQJ-KIOSKIII                                                                                      Page 8 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

5       INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein,
has been calibrated in accordance with the manufacturer's recommendations for utilizing
calibration equipment, which is traceable to recognized national standards.


6       SETUP OF EQUIPMENT UNDER TEST
6.1. DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary
accessories or support units. The following support units or accessories were used to form
a representative test configuration during the tests.
                                                                                                  Data         Power
 No.      Equipment          Model No.          Serial No.            FCC ID          Brand
                                                                                                  Cable         Cord
                                                                                                             Unshielded
    1      Notebook              B475          WB04861612               DOC          LENOVO         N/A
                                                                                                               1.80m
Note:    Grounding was established in accordance with the manufacturer’s requirements and conditions for
         the intended use.

6.2. CONFIGURATION OF SYSTEM UNDER TEST
See test photographs attached in Appendix II for the actual connections between EUT and
support equipment.




FCC ID : WQJ-KIOSKIII                                                                                      Page 9 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

7    FACILITIES AND ACCREDITATIONS
7.1. FACILITIES
All measurement facilities used to collect the measurement data are located at
    No10-1, Mingkeda Logistics Park, No.18 Huanguan South Rd., Guan Lan Town,
    Baoan District, Shenzhen, China
The sites are constructed in conformance with the requirements of ANSI C63.4, ANSI
C63.7 and CISPR Publication 22. All receiving equipment conforms to CISPR Publication
16-1, “Radio Interference Measuring Apparatus and Measurement Methods.”

7.2. ACCREDITATIONS
Our laboratories are accredited and approved by the following accreditation body according
to ISO/IEC 17025.
              USA                 A2LA
              China               CNAS
The measuring facility of laboratories has been authorized or registered by the following
approval agencies.
              Canada             Industry Canada
              Japan              VCCI(C-3478, R-3135, T-652, G-624)
              Taiwan             BSMI
              USA                FCC
Copies of granted accreditation certificates are available for downloading from our web site,
http://www.ccsrf.com

7.3. MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for
tests performed on the EUT as specified in CISPR 16-4-2:
                      Parameter                             Uncertainty
               Radiated Emission, 30 to 200 MHz
                                                                                 +/-3.6880dB
                       Test Site : 966(2)
              Radiated Emission, 200 to 1000 MHz
                                                                                 +/-3.6695dB
                       Test Site : 966(2)
                Radiated Emission, 1 to 8 GHz                                    +/-5.1782dB
                   Radiated Emission, 8 to 18 GHz                                +/-5.2173dB
                     Conducted Emissions                                         +/-3.6836dB
                          Band Width                                                178kHz
                     Peak Output Power MU                                        +/-1.906dB
                         Band Edge MU                                            +/-0.182dB
                    Channel Separation MU                                         416.178Hz
                        Duty Cycle MU                                              0.054ms
                    Frequency Stability MU                                          226Hz
This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2.
The measured result is above (below) the specification limit by a margin less than the
measurement uncertainty; it is therefore not possible to state compliance based on the 95%
level of confidence. However, the result indicates that compliance (non-compliance) is more
probable than non-compliance) with the specification limit.

FCC ID : WQJ-KIOSKIII                                                                                     Page 10 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

8    FCC PART 15.225 REQUIREMENTS
8.1. TIMING OF THE TRANSMITTER
LIMIT
             FCC
                                           Timing of the transmitter
(c) Unless otherwise specified, e.g. Section 15.255(b), when the radiated emission limits are expressed in
terms of the average value of the emission, and pulsed operation is employed, the measurement field
strength shall be determined by averaging over one complete pulse train, including blanking intervals, as
long as the pulse train does not exceed 0.1 seconds. As an alternative (provided the transmitter operates
for longer than 0.1 seconds) or in cases where the pulse train exceeds 0.1 seconds, the measured field
strength shall be determined from the average absolute voltage during a 0.1 second interval during which
the field strength is at its maximum value. The exact method of calculating the average field strength shall
be submitted with any application for certification or shall be retained in the measurement data file for
equipment subject to notification or verification.


MEASUREMENT
                                           Measurement parameter
Detector:                                                                      Positive peak
Sweep time:                                              100ms
Resolution bandwidth:                                    100kHz
Video bandwidth:                                         300kHz
Span:                                                    Zero span
Trace-Mode:                                              Single sweep


Duty cycle of the EUT: 100%

RESULT: passed




FCC ID : WQJ-KIOSKIII                                                                                     Page 11 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No.: C150205Z03-RP1

8.2. 99 % EMISSION BANDWIDTH
LIMIT
None; for reporting purposes only.

MEASUREMENT EQUIPMENT USED
                                   Radiated Emission Test Site 966(2)
                                                                           Serial           Last            Due
Name of Equipment             Manufacturer         Model Number
                                                                          Number         Calibration     Calibration
 PSA Series Spectrum
                                   Agilent              E4446A          US44300399        03/01/2015       03/01/2016
     Analyzer
 EMI TEST RECEIVER          ROHDE&SCHWARZ                 ESCI             100783         03/09/2015       03/08/2016
        Amplifier                  MITEQ             AM-1604-3000         1123808         03/18/2015       03/17/2016
  High Noise Amplifier             Agilent               8449B          3008A01838        03/18/2015       03/17/2016
Board-Band Horn Antenna         Schwarzbeck            BBHA 9170          9170-497        07/10/2014       07/09/2015
      Bilog Antenna             SCHAFFNER               CBL6143             5082          03/01/2015       03/01/2016
      Horn Antenna            SCHWARZBECK              BBHA9120             D286          03/01/2015       03/01/2016
      Loop Antenna             COM-POWER                 AL-130            121044         09/27/2014       09/26/2015
       Turn Table                   N/A                   N/A                N/A             N.C.R           N.C.R
        Controller             Sunol Sciences           SC104V            022310-1           N.C.R           N.C.R
        Controller                   CT                   N/A                N/A             N.C.R           N.C.R
 Temp. / Humidity Meter           Anymetre               JR913               N/A          02/28/2015       02/27/2016
     Antenna Tower                 SUNOL                  TLT2               N/A             N.C.R           N.C.R
        Test S/W                   FARAD                                   LZ-RF / CCS-SZ-3A2


Test Configuration


        EUT
                                             Spectrum Analyzer




TEST PROCEDURE
1. Place the EUT on the table and set it in the transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the
   antenna port to the spectrum analyzer.
3. Set the spectrum analyzer as RBW= 1kHz, VBW = 3kHz, Span = 10kHz, Sweep = auto.
4. Mark the peak frequency and 26dB (upper and lower) frequency.
5. Repeat until all the rest channels are investigated.

TEST RESULTS
No non-compliance noted.




FCC ID : WQJ-KIOSKIII                                                                                     Page 12 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1


    Test Data
       Bandwidth (TX / CH 13.56MHz)




FCC ID : WQJ-KIOSKIII                                                                                     Page 13 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

8.3. POWER LINE CONDUCTED EMISSIONS MEASUREMENT
8.3.1. LIMITS OF CONDUCTED EMISSIONS MEASUREMENT
According to §15.207(a), except as shown in paragraphs (b) and (c) of this section, for an
intentional radiator that is designed to be connected to the public utility (AC) power line, the
radio frequency voltage that is conducted back onto the AC power line on any frequency or
frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the following
table, as measured using a 50 µH/50 ohms line impedance stabilization network (LISN).
Compliance with the provisions of this paragraph shall be based on the measurement of the
radio frequency voltage between each power line and ground at the power terminal. The
lower limit applies at the boundary between the frequency ranges.
                                                                      Limits
     Frequency Range                                                 (dBμV)
          (MHz)
                                              Quasi-peak                                 Average
         0.15 to 0.50                           66 to 56*                                56 to 46*
           0.50 to 5                               56                                        46
            5 to 30                                60                                        50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.
(3) All emanations from a class A/B digital device or system, including any network of conductors and
    apparatus connected thereto, shall not exceed the level of field strengths specified above.


TEST INSTRUMENTS

                                    Conducted Emission Test Site
      Name of                                                                             Last        Due
                           Manufacturer         Model Number Serial Number
     Equipment                                                                         Calibration Calibration
EMI TEST RECEIVER ROHDE&SCHWARZ                         ESCI             100783         04/21/2014     04/21/2015

      LISN(EUT)          ROHDE&SCHWARZ              ENV216             101543-WX        03/01/2015     03/01/2016

         LISN                  EMCO                  3825/2            8901-1459        03/01/2015     03/01/2016

Temp. / Humidity Meter         VICTOR                HTC-1                 N/A          03/17/2015     03/17/2016

       Test S/W                FARAD                                  EZ-EMC/ CCS-3A1-CE

NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Request.




FCC ID : WQJ-KIOSKIII                                                                                     Page 14 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

8.3.2. TEST PROCEDURES (please refer to measurement standard)

z   The EUT and Support equipment, if needed, was placed on a non-conducted table,
    which is 0.8m above the ground plane and 0.4m away from the conducted wall.

z   The test equipment EUT installed received AC main power, through a Line Impedance
    Stabilization Network (LISN), which supplied power source and was grounded to the
    ground plane. All support equipment power received from a second LISN. The two
    LISNS provide 50 ohm/ 50uH of coupling impedance for the measuring instrument.
z   The EUT test program was started. Emissions were measured on each current carrying
    line of the EUT using an EMI Test Receiver connected to the LISN powering the EUT.
z   The frequency range from 150 kHz to 30 MHz was searched. The test data of the
    worst-case condition(s) was recorded. Emission levels under limit 20dB were not
    recorded.




FCC ID : WQJ-KIOSKIII                                                                                     Page 15 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No.: C150205Z03-RP1

8.3.3. TEST SETUP




                                                   Vert. reference plane

                                                                                               EMI receiver



                          40cm
                                       EUT



                                                            80cm




                LISN                                               Reference ground plane



     z     For the actual test configuration, please refer to the related item – Photographs of the Test
         Configuration.

8.3.4. DATA SAMPLE

Frequency QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average Line
           Reading Reading   Factor     Result    Result   Limit    Limit   Margin   Margin
  (MHz)    (dBuV)   (dBuV)    (dB)      (dBuV)   (dBuV)   (dBuV)   (dBuV)    (dB)     (dB)   (L1/L2)

  X.XXXX         32.69     25.65     11.52      44.21      37.17       65.78     55.79      -21.57    -18.62     L1


Factor          = Insertion loss of LISN + Cable Loss
Result          = Quasi-peak Reading/ Average Reading + Factor
Limit           = Limit stated in standard
Margin          = Result (dBuV) – Limit (dBuV)
L1              = Hot side
L2              = Neutral side




FCC ID : WQJ-KIOSKIII                                                                                     Page 16 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

8.3.5. TEST RESULTS

  Model No.             ViVOpay Kiosk III                           RBW,VBW              9 kHz
  Environmental o
               22 C, 45% RH                                         Test Mode            Normal
  Conditions
  Tested by             Eve Wang                                    Line                 L1

  Test Date             March 24, 2015




  Frequency QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average Remark
             Reading Reading   Factor     Result    Result   Limit    Limit   Margin   Margin
    (MHz)    (dBuV)   (dBuV)    (dB)      (dBuV)   (dBuV)   (dBuV)   (dBuV)    (dB)      (dB)  (Pass/Fail)

    0.1860      44.79       11.92     9.66       54.45     21.58       64.21     54.21        -9.76   -32.63     Pass

    0.2140      44.20       17.82     9.69       53.89     27.51       63.04     53.05        -9.15   -25.54     Pass

    0.3620      39.84       24.73     9.68       49.52      34.41      58.68     48.68        -9.16   -14.27     Pass

    2.0180      37.29       24.90     9.73       47.02     34.63       56.00     46.00        -8.98   -11.37     Pass

    7.4900      39.30       25.66     9.80       49.10     35.46       60.00     50.00     -10.90     -14.54     Pass

   13.5620      41.41       37.55     9.90       51.31     47.45       60.00     50.00        -8.69   -2.55      Pass

Note:
      1. Measuring frequencies from 0.15 MHz to 30MHz.
      2. The emissions measured in frequency range from 0.15 MHz to 30MHz were made with an
         instrument using Peak detector, Quasi-peak detector and average detector.
      3. “---” denotes the emission level was or more than 2dB below the Average limit.
      4. The IF bandwidth of SPA between 0.15MHz to 30MHz was 10kHz; the IF bandwidth of Test
         Receiver between 0.15MHz to 30MHz was 9kHz;
      5. L1= Line One (Live Line)

FCC ID : WQJ-KIOSKIII                                                                                     Page 17 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1



 Model No.           ViVOpay Kiosk III                        RBW,VBW                9 kHz
 Environmental o
              22 C, 45% RH                                    Test Mode              Normal
 Conditions
 Tested by           Eve Wang                                 Line                   L2

 Test Date           March 24, 2015




  Frequency QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average Remark
             Reading Reading   Factor     Result    Result   Limit    Limit   Margin   Margin
    (MHz)    (dBuV)   (dBuV)    (dB)      (dBuV)   (dBuV)   (dBuV)   (dBuV)    (dB)      (dB)  (Pass/Fail)

    0.2540      40.18      22.03      9.77       49.95     31.80      61.62      51.63     -11.67    -19.83      Pass

    0.3980      36.35      21.75      9.71       46.06     31.46      57.89      47.90     -11.83    -16.44      Pass

    0.4900      36.54      22.26      9.68       46.22      31.94     56.17      46.17       -9.95   -14.23      Pass

    0.7780      33.14      12.91      9.73       42.87     22.64      56.00      46.00     -13.13    -23.36      Pass

    6.3859      35.83      16.62      9.78       45.61     26.40      60.00      50.00     -14.39    -23.60      Pass

   13.5620      41.82      38.02      9.76       51.58     47.78      60.00      50.00     -8.42      -2.22      Pass

Note:
    1. Measuring frequencies from 0.15 MHz to 30MHz.
    2. The emissions measured in frequency range from 0.15 MHz to 30MHz were made
       with an instrument using Peak detector, Quasi-peak detector and average detector.
    3. “---” denotes the emission level was or more than 2dB below the Average limit.
    4. The IF bandwidth of SPA between 0.15MHz to 30MHz was 10kHz; the IF
        bandwidth of Test Receiver between 0.15MHz to 30MHz was 9kHz;
    5. L2= Line Two (Neutral Line)


FCC ID : WQJ-KIOSKIII                                                                                     Page 18 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

8.4. SPURIOUS EMISSIONS MEASUREMENT
8.4.1. LIMITS OF RADIATED EMISSIONS MEASUREMENT

LIMIT
According to §15.225,
(a) The field strength of any emissions within the band 13.553 – 13.567 MHz shall not
    exceed 15,848 microvolts / meter at 30 meters.
(b) Within the bands 13.410 – 13.553 MHz and 13.567 -13.710 MHz, the field strength of
    any emissions shall not exceed 334 microvolts / meter at 30 meters.
(c) Within the bands 13.110 – 13.410 MHz and 13.710 – 14.010 MHz the field strength of
    any emissions shall not exceed 106 microvolts / meter at 30 meters.
(d) The field strength of any emissions appearing outside of the 13.110 – 14.010 MHz and
    shall not exceed the general radiated emission limits in §15.209.
1. Except as provided elsewhere in this Subpart, the emissions from an intentional radiator
   shall not exceed the field strength levels specified in the following table:

            Frequency (MHz)                   Field Strength (μV/m)            Measurement Distance (m)
               0.009-0.490                          2400/F(kHz)                               300
               0.490-1.705                         24000/F(kHz)                                30
                1.705-30.0                                30                                   30
                    30-88                                100*                                   3
                   88-216                                150*                                   3
                  216-960                                200*                                   3
                Above 960                                 500                                   3
    Remark: Except as provided in paragraph (g), fundamental emissions from intentional radiators
    operating under this Section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz,
    174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under
    other sections of this Part, e.g., Sections 15.231 and 15.241.




FCC ID : WQJ-KIOSKIII                                                                                     Page 19 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No.: C150205Z03-RP1

8.4.2. TEST INSTRUMENTS

                                   Radiated Emission Test Site 966(2)
                                                                           Serial           Last            Due
Name of Equipment             Manufacturer         Model Number
                                                                          Number         Calibration     Calibration
 PSA Series Spectrum
                                   Agilent              E4446A          US44300399        03/01/2015       03/01/2016
     Analyzer
 EMI TEST RECEIVER          ROHDE&SCHWARZ                 ESCI             100783         03/09/2015       03/08/2016
          Amplifier                MITEQ             AM-1604-3000         1123808         03/18/2015       03/17/2016
     High Noise Amplifier          Agilent               8449B          3008A01838        03/18/2015       03/17/2016
Board-Band Horn Antenna         Schwarzbeck            BBHA 9170          9170-497        07/10/2014       07/09/2015
        Bilog Antenna           SCHAFFNER               CBL6143             5082          03/01/2015       03/01/2016
        Horn Antenna          SCHWARZBECK              BBHA9120             D286          03/01/2015       03/01/2016
        Loop Antenna           COM-POWER                 AL-130            121044         09/27/2014       09/26/2015
         Turn Table                 N/A                   N/A                N/A             N.C.R           N.C.R
          Controller           Sunol Sciences           SC104V            022310-1           N.C.R           N.C.R
          Controller                 CT                   N/A                N/A             N.C.R           N.C.R
 Temp. / Humidity Meter           Anymetre               JR913               N/A          02/28/2015       02/27/2016
       Antenna Tower               SUNOL                  TLT2               N/A             N.C.R           N.C.R
          Test S/W                 FARAD                                   LZ-RF / CCS-SZ-3A2
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Required.

8.3.3 TEST PROCEDURE (please refer to measurement standard)
1.     The EUT is placed on a turntable, which is 0.8m above ground plane.
2.     The turntable shall be rotated for 360 degrees to determine the position of maximum
       emission level.
3.     EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
       out the highest emissions.
4.     Maximum procedure was performed on the six highest emissions to ensure EUT
       compliance.
5.     And also, each emission was to be maximized by changing the polarization of
       receiving antenna both horizontal and vertical.
6.     Set the spectrum analyzer in the following setting as:
       Belove 30MHz:
             9kHz~150kHz: RBW=200Hz / VBW=600Hz / Sweep=AUTO
             150kHz~30MHz: RBW=9kHz / VBW=27kHz / Sweep=AUTO
       Above 30MHz:
             RBW=100kHz / VBW=300kHz / Sweep=AUTO
7.     Repeat above procedures until the measurements for all frequencies are complete.




FCC ID : WQJ-KIOSKIII                                                                                     Page 20 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

8.4.2.1. TEST SETUP

Below 30MHz


                                                                                   Anten na
                                                                                    tower


                                         10m
                                                                                      Loop antenna
         EU T
                                           4m
                                                                                   Spe ctrum /
                                                                                    Re ce ive r


                Turnta ble                      1m
                                  0.8m
                                                                                  P re -a mp




    R ef er ence gr ound pla ne



Below 1 GHz


                                                                                        Antenna
                                                                                         tower


                                          3m                                             Bi-log
                                                                                        antenna
                EUT
                                                4m
                                                                                      Spectrum
                                                                                      analyzer


                       Turntable                     1m
                                         0.8m




          Reference ground plane


For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.




FCC ID : WQJ-KIOSKIII                                                                                     Page 21 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

8.4.2.2. DATA SAMPLE
Below 1GHz
                                  Correction                                                  Antenna
  Frequency         Reading                         Result         Limit         Margin                     Remark
                                   Factor                                                      Pole
    (MHz)           (dBuV)                        (dBuV/m)       (dBuV/m)         (dB)
                                   (dB/m)                                                      (V/H)
   XXX.XXXX           37.47         -16.41          21.06          40.00         -18.94           V           Peak


Above 1GHz
                                  Correction                                                  Antenna
  Frequency         Reading                         Result         Limit         Margin                     Remark
                                   Factor                                                      Pole
    (MHz)           (dBuV)                        (dBuV/m)       (dBuV/m)         (dB)
                                   (dB/m)                                                      (V/H)
  XXXX.XXXX           55.54          4.56           60.10          74.00         -13.90           V           Peak
  XXXX.XXXX           29.66          4.56           34.22          54.00         -19.78           V           AVG

Frequency (MHz)                    = Emission frequency in MHz
Reading (dBuV)                     = Uncorrected Analyzer / Receiver reading
Correction Factor (dB/m)           = Antenna factor + Cable loss – Amplifier gain
Result (dBuV/m)                    = Reading (dBuV) + Corr. Factor (dB/m)
Limit (dBuV/m)                     = Limit stated in standard
Margin (dB)                        = Result (dBuV/m) – Limit (dBuV/m)
Q.P.                               = Quasi-peak Reading
Peak                               = Peak Reading
AVG                                = Average Reading




FCC ID : WQJ-KIOSKIII                                                                                     Page 22 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

8.4.2.3. TEST RESULTS

Blow 1GHz

Operation Mode:             TX / CH 1 (13.56)                    Test Date:        March 20, 2015
Temperature:                24°C                                 Tested by:        Eve Wang
Humidity:                   52 % RH                              Polarity:         Ver. / Hor.
Fundamental
  Frequency           Reading        Correction          Result          Limit           Margin          Remark
    (MHz)             (dBuV)          Factor           (dBuV/m)        (dBuV/m)           (dB)
                                      (dB/m)
    13.5600            49.65            14.29            63.94           124.00           -60.06           Peak




FCC ID : WQJ-KIOSKIII                                                                                     Page 23 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1




   Frequency           Reading       Correction Result     Limit                Margin       Antenna       Remark
                                      Factor                                                  Pole
      (MHz)             (dBuV)        (dB/m)    (dBuV/m) (dBuV/m)                 (dB)
                                                                                              (V/H)
     38.7300             42.59          -11.27        31.32         40.00         -8.68          V           Peak
     99.8400             38.64          -14.13        24.51         43.50        -18.99          V           Peak
     199.7500            38.38          -12.20        26.18         43.50        -17.32          V           Peak
     600.3600            37.79          -5.84         31.95         46.00        -14.05          V           Peak
     666.3200            45.58          -4.87         40.71         46.00         -5.29          V           Peak
     900.0900            32.91          -2.33          30.58        46.00        -15.42          V          Peak

     39.7000             39.07          -11.25         27.82        40.00        -12.18          H           Peak
     232.7300            42.12          -10.85         31.27        46.00        -14.73          H           Peak
     299.6600            40.48          -10.01         30.47        46.00        -15.53          H           Peak
     600.3600            37.45          -5.84          31.61        46.00        -14.39          H           Peak
     666.3200            40.40          -4.87          35.53        46.00        -10.47          H           Peak
     834.1300            36.57          -3.07          33.50        46.00        -12.50          H           Peak
**Note: The emission found is too lower to record between lowest internal used/generated
   frequency to 30 MHz.
REMARKS:
1. Radiated emissions measured in frequency range from 9kHz to 1GHz were made with an
   instrument using peak/quasi-peak detector mode.
2. Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit or
   as required by the applicant.
3. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with
   “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the
   applicable limit) and considered that's already beyond the background noise floor.
4. Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m)




FCC ID : WQJ-KIOSKIII                                                                                     Page 24 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1


8.5. FREQUENCY STABILITY
LIMIT

According to §15.225(e), the frequency tolerance of the carrier signal shall be maintained
within +/- 0.01% of the operating frequency over a temperature variation of –20 degrees to
+50 degrees C at normal supply voltage, and for a variation in the primary supply voltage
from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. For
battery operated equipment, the equipment tests shall be performed using a new battery.

Test Configuration

Temperature and Voltage Measurement (under normal and extreme test conditions)



                                                      Temperature Chamber




        Spectrum Analyzer                                          EUT




                                                     AC/DC Power supply


TEST PROCEDURE

1. Place the EUT on the table and set it in the transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the
   antenna port to the spectrum analyzer.
3. Set the environment into appropriate environment.
4. Set the spectrum analyzer as RBW=1kHz, VBW = RBW, Span = 200kHz, Sweep = auto.
5. Mark the peak frequency and measure the frequency tolerance using frequency counter
   function.
6. Repeat until all the results are investigated.




FCC ID : WQJ-KIOSKIII                                                                                     Page 25 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                    Report No.: C150205Z03-RP1

TEST RESULTS
No non-compliance noted.


 Temperature Variations
                               Measured          Delta
     Temp.        Voltage                                    Tolerance        Limit        Margin         Result
       o
                               Frequency      Frequency
      ( C)         (VAC)                                         (%)           (±%)          (%)       (Pass/Fail)
                                  (MHz)           (Hz)
      -20                       13.56008           10          0.00007         0.01       -0.00993         Pass

      -10                       13.56003           30          0.00022         0.01       -0.00978         Pass

       0                        13.56001           10          0.00007         0.01       -0.00993         Pass

       10                       13.56017          170          0.00125         0.01       -0.00875         Pass
                     7.5
       20                       13.56001           10          0.00007         0.01       -0.00993         Pass

       30                       13.56008           80          0.00059         0.01       -0.00941         Pass

       40                       13.55998           20          0.00015         0.01       -0.01015         Pass

       50                       13.56010          100          0.00074         0.01       -0.00926         Pass


 Voltage Variations
                               Measured          Delta
     Temp.        Voltage                                    Tolerance        Limit        Margin         Result
                               Frequency      Frequency
      (oC)         (VAC)                                         (%)           (±%)          (%)       (Pass/Fail)
                                  (MHz)           (Hz)
                    6.75        13.56015          150          0.00111         0.01       -1.00889         Pass

       20           7.50        13.56001           10          0.00007         0.01       -2.00993         Pass

                    8.25        13.56004           40          0.00029         0.01       -3.00971         Pass




FCC ID : WQJ-KIOSKIII                                                                                     Page 26 / 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Document Created: 2015-05-12 10:47:11
Document Modified: 2015-05-12 10:47:11

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC