Test Report

FCC ID: VH9KDC500

Test Report

Download: PDF
FCCID_2747389

                                                                 www.etl.re.kr
&—Testing Laboratory




                                       Electromagnetic Emission
           F CC MEA SURE MENT REP OR T
                                 CERTIFICATION OF COMPLIANCE
                                 FCC Part 15 Certification Measurement

   PRODUCT                                  Mobile POS
  MODEL/Serial No.                          KDC500 / NONE
  MULTIPLE MODEL
  FCC ID                                    VH9KDC500
  APPLICANT                                 AISOLUTION CO., LTD.
                                            28—4, Samyang—ro 29—gil, Gangbuk—gu, Seoul, South Korea
                                            Attn.: KITAE, LEE / Assistant Director
  MANUFACTURER                              AISOLUTION CO., LTD.
                                            28—4, Samyang—ro 29—gil, Gangbuk—gu, Seoul, South Korea
  EQUIPMENT CLASS                           DXX — Part 15 Low Power Communication Device Transmitter
  TYPE OF MODULATION                        ASK
  FREQUENCY CHANNEL                         1 CH
  ANTENNA TYPE                              PCB Pattern Antenna (Integral)
  RULE PART(S)                              FCC Part 15 Subpart C
  FCC PROCEDURE                             ANSI C63.10—2009
  TEST REPORT No.                           ETLT150819.0064
  DATES OF TEST                             August 26, 2015 to August 27, 2015
  REPORT ISSUE DATE                         September 10, 2015
  TEST LABORATORY                           ETL Inc. (FCC Designation Number : KROO22)

 The Mobile POS, Model KDC500 has been tested in accordance with the measurement procedures
 specified in ANSI C63.10—2009 at the ETL Test Laboratory and has been shown to be complied with the
 electromagnetic radiated emission limits specified in FCC Rule Part15 Subpart C section 15.247.
 1 attest to the accuracy of data. All measurement herein was performed by me or was made under my
 supervision and is correct to the best of my knowledge and belief. | assume full responsibility for the
 completeness of these measurements and vouch for the qualifications of all persons taking them.
 The results of testing in this report apply to the product/system which was tested only. Other similar
 equipment will not necessarily produce the same results due to production tolerance and measurement
 uncertainties.




              Prepared by:                                                     Reviewed by:
              Seok Lyong, Choi (Test Engineer)                                 Kug Kyoung, Yoon (Chief Engineer)
              September 10, 2015                                               September 10, 2015

                                                               ETL Inc.
         Head office: #371—51, Gasan—dong, Geumcheon—gu, Seoul, 153—803, Korea
         Open site: #499—1, Sagot—ri, Seosin—myeon, Hwaseong—si, Gyeonggi—do, 445—882, Korea
                                             Tel: 82—2—858—0786 Fax: 82—2—858—0788


                                          The test report merely corresponds to the test sample(s).
                       This report shall not be reproduced, in whole or in part without the written approval of ETL Inc.


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




                                                      Table of Contents

       FCC Measurement Report

              1. Introduction
              2. Product Information
              3. Description of Tests
              4. Test Condition
              5. Test Results
                 5.1 Summary of Test Results
                 5.2 Conducted Emissions
                 5.3 Radiated Emissions
                 5.4 13.56 MHz Carrier Field Strength within the Bands
                 5.5 Occupied Bandwidth
                 5.6 Frequency Tolerance
              6. Sample Calculation
              7. List of test Equipment used for Measurement




                                           Report no. ETLT150819.0064, Page 2 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




FCC MEASUREMENT REPORT
Scope – Measurement and determination of electromagnetic emission (EME) of radio frequency devices
including intentional radiators and/or unintentional radiators for compliance with the technical rules and
regulations of the U.S Federal Communications Commission(FCC)

General Information


     Applicant Name                   : AISOLUTION CO., LTD.

     Address                          : 28-4, Samyang-ro 29-gil, Gangbuk-gu, Seoul, South Korea

     Attention                        : KITAE, LEE / Assistant Director



        EUT Type                            :    Mobile POS
        Model Number                        :    KDC500
        S/N                                 :    NONE
        Freq. Range                         :    13.56 MHz
        Modulation Technique                :    ASK
        Antenna Type                        :    PCB Pattern Antenna (Integral)
        Environmental of Tests              :    Temperature: (26.2 ± 2.8) °C
                                                  Humidity: (52 ± 10) % R.H.
                                                  Atmospheric Pressure: (100.5 ± 0.2) kPa
        FCC Rule Part(s)                    :    FCC Part 15 Subpart C
        Test Procedure                      :    ANSI C63.10-2009
        FCC Classification                   :   DXX - Part 15 Low Power Communication Device Transmitter
        Place of Tests                       :   ETL Inc. Testing Lab. (FCC Designation Number : KR0022)

                                                  Radiated Emission test 1;
                                                  #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si,
                                                  Gyeonggi-do, 445-882, Korea

                                                  Radiated Emission test 2 and Conducted Emission test;
                                                  #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea




                                           Report no. ETLT150819.0064, Page 3 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




1. INTRODUCTION
 The measurement test for radiated and conducted emission test was conducted at the ETL Inc. The site is
constructed in conformance with the requirements of the ANSI C63.10-2009 and CISPR Publication 16. The
ETL has site descriptions on file with the FCC for 3 m and 10 m site configurations. Detailed description of test
facility was found to be in compliance with FCC Rules according to the ANSI C63.10-2009 and registered to the
Federal Communications Commission (FCC Designation Number : KR0022).

 The measurement procedure described in American National Standard for Method of Measurement of Radio-
Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (ANSI
C63.10-2009) was used in determining radiated and conducted emissions from the AISOLUTION CO., LTD.
Model: KDC500




                                           Report no. ETLT150819.0064, Page 4 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




2. PRODUCT INFORMATION
2.1 Equipment Description
 The Equipment Under Test (EUT) is the Mobile POS (model: KDC500).

 The model KDC500 is basic model that was tested.


2.2 General Specification

                  Item                                                                Specification

     Main Processor                      120 MHz ARM Cortex-M4
                                         1 MB program flash, 128 kB RAM, 32-byte secure key storage,
     Memory
                                         8 MB user data flash
     Display                             128 x 64 monochrome

                                         Secure Touch Pinpad (15 buttons) + 2 Scan buttons for barcode module
     Keypad
                                         ‘0’ to ‘9’, Up/Fn, Down/Menu, Cancel, Clear and Enter

     Battery                             Lithium-Ion 3.7 V DC, 4.18 Wh

     Charging                            Micro-USB, Charging Cradle or Wireless Charging

     Mag-Stripe Reader                   Track 1/2/3, Bi-directional, ISO 7810, 7811, 7813

     Smart Card Reader                   EMV L1 and L2, SAM

     Contactless and NFC                 ISO 14443, MIFARE, Felica, MasterCard PayPass, Visa PayWave

     Security                            PCI PTS V4

                                         For PIN : T-DES (128-bit)
     Encryption
                                         For Card data : T-DES (128-bit), AES (128-bit)

     Key Management                      DUKPT

     Key Injection                       Key Loader

     OS compatibility                    All major OS

     Barcode Scanner                     Optional - 1D/2D

     Interfaces                          Bluetooth (V2.1 + EDR, Class 2, SPP/MFi), USB to Serial (Micro USB port)

     Dimensions                          49 mm (W) x 117 mm (L) x 25 mm (H) (1.93” x 4.6” x 0.98”)

     Weight                              5.6 oz (160 grams)

     Drop Spec                           4 feet (1.22 M)




                                           Report no. ETLT150819.0064, Page 5 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




                  Item                                                                Specification

     Operating Temperature               (82.5 ± 50.5) ℉ ((22.5 ± 22.5) ℃)

     Storage Temperature                 (54.5 ± 58.5) ℉ ((12.5 ± 32.5) ℃)

     Humidity                            (45 ± 40) % R.H. (non condensing)

                                         ASK

     NFC                                 13.56 MHz

                                         PCB Pattern Antenna

     High Internal Frequency             NFC X-tal: 27.12 MHz




                                           Report no. ETLT150819.0064, Page 6 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




3. DESCRIPTION OF TESTS
The tests documented in this report were performed in accordance with ANSI C63.10-2009 and FCC CFR 47
2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055, 2.1057, 15.207, 15.209 and 15.247.

3.1 Radiated Emission Measurement
 Radiated emission measurements were made in accordance with § 13 in ANSI C63.10-2009 "Measurement of
Intentional radiators” The measurements were performed over the frequency range of 30 MHz to 40 GHz using
antenna as the input transducer to a Spectrum analyzer or a Field Intensity Meter. The measurements were
made with the detector set for "Peak, Quasi-peak, Average" within a bandwidth of 120 kHz and above 1 GHz is
1 MHz.


  Preliminary measurements were made at 3 m using broadband antennas, and spectrum analyzer to determine
the frequency producing the maximum emission in shielded room. Appropriate precaution was taken to ensure
that all emission from the EUT were maximized and investigated. The system configuration, mode of operation,
turntable azimuth and height with respect to the antenna were noted for each frequency found. The spectrum
was scanned from 30 MHz to 1 000 MHz using Log-Bicon antenna. Above 1 GHz, linearly polarized double
ridge horn antennas were used. Final measurements were made open site or SVSWR chamber at 3 m. The test
equipment was placed on a styrofoam table. Sufficient time for the EUT, support equipment, and test equipment
was allowed in order for them to warm up to their normal operating condition. Each frequency found during pre-
scan measurements was re-examined by manual. The EUT, support equipment and interconnecting cables
were re-configured to the set-up producing the maximum emission for the frequency and were placed on top of
a 0.8 m high nonmetallic 1.0 m x 1.5 m table. The EUT, support equipment, and interconnecting cables were re-
arranged and manipulated to maximize each emission. The turntable containing the system was rotated; the
antenna height was varied 1 m to 4 m and stopped at the azimuth or height producing the maximum emission.

 Varying the mode of operating frequencies of the EUT maximized each emission. The system was tested in all
the three orthogonal planes and changing the polarity of the antenna. The worst-case emissions are recorded in
the data tables. If necessary, the radiated emission measurement could be performed at a closer distance to
ensure higher accuracy and the results were extrapolated to the specified distance using an inverse linear
distance extrapolation factor (20 dB/decade) as per section 15.31(f).


 Photographs of the worst-case emission can be seen in Photographs of the worst-case emission test setup
can be seen in Appendix B.




                                           Report no. ETLT150819.0064, Page 7 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                              FCC ID: VH9KDC500




3.1.1 Radiated Emission Limits:
(1) According to §15.209 Radiated emission limits, general requirements

(a) Except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall not exceed the
field strength levels specified in the following table:

                        Frequencies                         Field Strength                      Measurement Distance
                           [MHz]                                [µV/m]                                  [m]
                         0.009 - 0.490                        2400/F (kHz)                                    300
                         0.490 - 1.705                       24000/F (kHz)                                     30
                          1.705 - 30.0                               30                                        30
                             30 - 88                               100**                                       3
                            88 - 216                               150**                                       3
                           216 - 960                               200**                                       3
                           Above 960                                500                                        3

** Fundamental emissions from intentional radiators operating under this Section shall not be located in the
frequency bands 54 MHz - 72 MHz, 76 MHz - 88 MHz, 174 MHz - 216 MHz or 470 MHz - 806 MHz. However,
operation within these frequency bands is permitted under other sections of this Part, e.g., Sections 15.231 and
15.241




                                           Report no. ETLT150819.0064, Page 8 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea     Tel : 82-2-858-0786    Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                          ETLQP-21-F40-0


                                          FCC TEST REPORT                                                             FCC ID: VH9KDC500




3.2 Carrier field strength and field strength outside 13.110 MHz - 14.010 MHz
    and occupied bandwidth
(1) According to §15.225 Operation within the band 13.110 MHz - 14.010 MHz
(a) The field strength of any emissions within the band 13.553 MHz - 13.567 MHz shall not exceed 15 848 micro
volts/meter at 30 meters
(b) Within the bands 13.410 MHz - 13.553 MHz and 13.567 MHz - 13.710 MHz, the field strength of any
emissions shall not exceed 334 microvolts/meter at 30 meters
(c) Within the bands 13.110 MHz - 13.410 MHz and 13.710 MHz - 14.010 MHz, the field strength of any
emissions shall not exceed 106 microvolts/meter at 30 meters
(d) The field strength of any emissions appearing outside of the 13.110 MHz - 14.010 MHz band shall not
exceed the general radiated emission limits in § 15.209

            Frequency                   Field Strength Limit               Field Strength Limit                Field Strength Limit
              [MHz]                        [µV/m] @ 30 m                   [dB(µV/m)] @ 30 m                    [dB(µV/m)] @ 3 m
          13.110 - 13.410                            106                                40.5                           80.5
          13.410 - 13.553                            334                                50.5                           90.5
          13.553 - 13.567                          15 848                               84.0                          124.0
          13.567 - 13.710                            334                                50.5                           90.5
          13.710 - 14.010                            106                                40.5                           80.5



(2) According to §15.215(c) Occupied bandwidth
(a) Intentional radiators operating under the alternative provisions to the general emission limits, as contained in
§ 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20 dB bandwidth of
the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the
equipment operates, is contained within the frequency band designated in the rule section under which the
equipment is operated. The requirement to contain the designated bandwidth of the emission within the
specified frequency band includes the effects from frequency sweeping, frequency hopping and other
modulation techniques that may be employed as well as the frequency stability of the transmitter over expected
variations in temperature and supply voltage. If frequency stability is not specified in the regulations, it is
recommended that the fundamental emission be kept within at least the central 80 % of the permitted band in
order to minimize the possibility of out-of-band operation.


3.3 Frequency tolerance
(1) According to §15.225 Operation within the band 13.110 MHz - 14.010 MHz
(e) The frequency tolerance of the carrier signal shall be maintained within ± 0.01 % of the operating frequency
over a temperature variation of -20 ℃ to +50 ℃ at normal supply voltage, and for a variation in the primary
supply voltage from 85 % to 115 % of the rated supply voltage at a temperature of 20 ℃. For battery-operated
equipment, the equipment tests shall be performed using a new battery.




                                           Report no. ETLT150819.0064, Page 9 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                           ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




3.4 Conducted Emission Measurement
 Conducted emissions measurements were made in accordance with section § 13 in ANSI C63.10-2009
"measurement of intentional radiators" The measurements were performed over the frequency range of 0.15
MHz to 30 MHz using a 50 Ω/50 μH LISN as the input transducer to a Spectrum Analyzer or a Test Receiver.
The measurements were made with the detector set for "Peak" amplitude within a bandwidth of 9 kHz or for
"quasi-peak" within a bandwidth of 9 kHz.


  The line-conducted emission test is conducted inside a shielded anechoic chamber room with 1 m x 1.5 m x
0.8 m wooden table which is placed 0.4 m away from the vertical wall and 1.5 m away from the side wall of the
chamber room. Two LISN are bonded to the shielded room. The EUT is powered from the LISN and the support
equipment is powered from the other LISN. Power to the LISNs are filtered by a noise cut power line filters. If
the EUT is a DC-powered device, power will be derived from the source power supply it normally will be
powered from and these supply lines will be connected to the LISN. Non-inductive bundling to a 1 m length
shortened all interconnecting cables more than 1 m. Sufficient time for the EUT, support equipment, and test
equipment was allowed in order for them to warm up to their normal operating condition. The RF output of the
LISN was connected to the EMI Test Receiver to determine the frequency producing the maximum emission
from the EUT. The frequency producing the maximum level was reexamined using to set Quasi-Peak mode by
manual, after scanned by automatic Peak mode from 0.15 MHz to 30 MHz. The bandwidth of the spectrum
analyzer was set to 9 kHz. The EUT, support equipment, and interconnecting cables were arranged and
manipulated to maximize each emission.


 Photographs of the worst-case emission can be seen in Photographs of the worst-case emission test setup
can be seen in Appendix B.




                                          Report no. ETLT150819.0064, Page 10 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                              FCC ID: VH9KDC500




3.5 FCC Part 15.205 Restricted Bands of Operations
  (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any of the
frequency bands listed below:

                MHz                                 MHz                                 MHz                              GHz
          0.090 - 0.110
          1                          16.42 - 16.423                399.9 - 410                                        4.5 - 5.15
          0.495 - 0.505
                                 16.694 75 - 16.695 25              608 - 614                                         5.35 - 5.46
       2.173 5 - 2.190 5
                                 16.804 25 - 16.804 75             960 - 1 240                                        7.25 - 7.75
          4.125 - 4.128
                                       25.5 - 25.67               1 300 - 1 427                                       8.025 - 8.5
      4.177 25 - 4.177 75
                                       37.5 - 38.25              1 435 - 1 626.5                                       9.0 - 9.2
      4.207 25 - 4.207 75
                                         73 - 74.6              1 645.5 - 1 646.5                                      9.3 - 9.5
          6.215 - 6.218
                                        74.8 - 75.2               1 660 - 1 710                                       10.6 - 12.7
      6.267 75 - 6.268 25
                                       108 - 121.94             1 718.8 - 1 722.2                                    13.25 - 13.4
      6.311 75 - 6.312 25
                                         123 - 138                2 200 - 2 300                                      14.47 - 14.5
          8.291 - 8.294
                                     149.9 - 150.05               2 310 - 2 390                                      15.35 - 16.2
          8.362 - 8.366
                                156.524 75 - 156.525 25          2 483.5 - 2 500                                      17.7 - 21.4
      8.376 25 - 8.386 75
                                      156.7 - 156.9               2 690 - 2 900                                      22.01 - 23.12
      8.414 25 - 8.414 75
                                   162.012 5 - 167.17             3 260 - 3 267                                       23.6 - 24.0
        12.29 - 12.293
                                     167.72 - 173.2               3 332 - 3 339                                       31.2 - 31.8
     12.519 75 - 12.520 25
                                         240 - 285               3 345.8 - 3 358                                     36.43 - 36.5
     12.576 75 - 12.577 25
                                        322 - 335.4               3 600 - 4 400                                           (2)
          13.36 - 13.41
   1
     Until February 1, 1999, this restricted band shall be 0.490 MHz - 0.510 MHz.
   2
     Above 38.6

  (b) Except as provided in paragraphs (d) and (e), the field strength of emissions appearing within these
frequency bands shall not exceed the limits shown in Section 15.209. At frequencies equal to or less than
1 000 MHz, compliance with the limits in Section 15.209 shall be demonstrated using measurement
instrumentation employing a CISPR quasi-peak detector. Above 1 000 MHz, compliance with the emission
limits in Section 15.209 shall be demonstrated based on the average value of the measured emissions. The
provisions in Section 15.35 apply to these measurements.


3.6 Antenna connection requirement
(1) According to §15.203
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a
unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this
Section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the
use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier
current devices or to devices operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or
15.221. Further, this requirement does not apply to intentional radiators that must be professionally installed,
such as perimeter protection systems and some field disturbance sensors, or to other intentional radiators which,
in accordance with Section 15.31(d), must be measured at the installation site. However, the installer shall be
responsible for ensuring that the proper antenna is employed so that the limits in this Part are not exceeded.




                                          Report no. ETLT150819.0064, Page 11 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                            ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




4. TEST CONDITION
4.1 Test Configuration
 The device was configured for testing in a typical fashion (as a customer would normally use it). During the
 tests, the following conditions and configurations were used.

* This test was applied to X, Y, Z. and the worst result were investigated and reported.


4.2 Description of Test modes
 Mobile POS that has the control software.


4.3 The setup drawing(s)




                     Notebook                       EUT
                     Computer




                                                    Barcode




                                    : Signal Line
                                    : Power Line
                                    : Adapter




                                          Report no. ETLT150819.0064, Page 12 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                                   FCC ID: VH9KDC500




5. TEST RESULTS
5.1 Summary of Test Results
The measurement results were obtained with the EUT tested in the conditions described in this report. Detailed
measurement data and plots showing the maximum emission of the EUT are reported.


        Test Rule Parts                                 Measurement Required                                                 Result

          15.207(a),(d)            Conducted emissions                                                                       Pass *

             15.209                Radiated emissions
                                                                                                                              Pass
            15.225(d)              Field strength outside 13.110 MHz - 14.010 MHz

        15.225(a)(b)(c)            13.56 MHz carrier field strength within the bands                                          Pass

              15.215               Occupied Bandwidth                                                                         Pass

            15.225(e)              Frequency Tolerance                                                                        Pass
                                                                                                                     Integral antenna which is
              15.203               Antenna connection requirement                                                    permanently attached
                                                                                                                     and cannot be replaced.

   * This test was tested at main host computer (EUT was connected USB port of the host computer).

The data collected shows that the AISOLUTION CO., LTD. / Mobile POS / KDC500 complied with technical
requirements of above rules part 15.207, 209 and 15.247 Limits.

The equipment is not modified anything, mechanical or circuits to improve EMI status during a measurement.
No EMI suppression device(s) was added and/or modified during testing.




                                          Report no. ETLT150819.0064, Page 13 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                                  ETLQP-21-F40-0


                                          FCC TEST REPORT                                                                 FCC ID: VH9KDC500




5.2 Conducted Emissions Measurement

       EUT                                    Mobile POS / KDC500 (S/N: N/A)
       Limit apply to                         FCC Part 15.207
       Test Date                              August 27, 2015
       Environmental of Test                  (24.3 ± 0.3) °C, (43 ± 1) % R.H., (100.5 ± 0.0) kPa
       Operating Condition                    RF transmitting continuously during the tested.
       Result                                 Passed by 14.39 dB

      Limit

        For an intentional radiator that is designed to be connected to the public utility (AC) power line, the
      radio frequency voltage that is conducted back onto the AC power line on any frequency or
      frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the following table, as
      measured using a 50 μH/50 ohms line impedance stabilization network (LISN). Compliance with the
      provisions of this paragraph shall be based on the measurement of the radio frequency voltage
      between each power line and ground at the power terminal. The lower limit applies at the boundary
      between the frequencies ranges.

                                                                                      Conducted limit
              Frequency of Emission                                                      [dB(μV)]
                     [MHz]
                                                                 Quasi-peak                                      Average

                      0.15 - 0.5                                  66 to 56 *                                    56 to 46 *

                        0.5 - 5                                         56                                           46

                        5 - 30                                          60                                           50
      * Decreases with the logarithm of the frequency.

      Test Results

      - Refer to see the measured plot in next page.




                                          Report no. ETLT150819.0064, Page 14 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                             ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




Conducted Emission Test Data
      The following data and graph shows the highest levels of conducted emissions on both polarizations of
      hot and neutral line.
      Detector mode: CISPR Quasi-Peak mode (6 dB Bandwidth: 9 kHz)

      NOTES:
                  1.   Please see the measured data and graph in next page.
                  2.   The Level (Result) value was included the reading, LISN factor and cable loss.
                  3.   Delta(Margin) value = Limit – Level (Result)
                  4.   If the Quasi-Peak limit is met when using a Peak detector receiver, the EUT shall be deemed to
                       meet both limits and measurement with the Quasi-Peak detector receiver is unnecessary.
                  5.   If the average limit is met when using a Quasi-peak detector receiver, the EUT shall be deemed to
                       meet both limits and measurement with the average detector receiver is unnecessary.
                  6.   Measurements were performed at the AC Power Inlet in the frequency band of 150 kHz ~ 30 MHz
                       according to the FCC Part 15 Class B.
                  7.   Frequency of 13.56 MHz is excluded. It is because the carrier frequency.




                                          Report no. ETLT150819.0064, Page 15 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500



Line: HOT




                                          Report no. ETLT150819.0064, Page 16 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


IET'I_e
&Testing Laboratory


  ETL EMC Laboratory
  Conducted Emission Test Result
  Eut                    ETcrI50819.0064
  Manut:
  Op Cond
  Operator
  Test Spec
  Comment                H


  Prescan Measurement:          Detectors:      X PK7+ AV
                                Meas Time:      see scan settings
                                Peaks:          16
                                Acc Margin      10 a8
  Peak Search Results

  Frequency          PK Level        PK Limit      PK Delta:
  Mz                 dBuV           dBuv           a8
  o.179              34.20          cass           3024
  0217               34.22          c203           2871
  0.304              3346           sr0s           24.52
  on                 4161           56.00          14.30
  133                s3.38          56.00          2262
  24                 3257           56.00          2343
  3.035              32.50          56.00          2350
  4.105              sa2r           56.00          2273
  s.ass              3421           60.00          25.70
  s.e5               3567           60.00          2433
  7.ras              36.06          60.00          2304
  1341               45.12          60.00          1488
  2705               41.09          60.00          1801

  Frequency          AV Level       AV Limit       AV Delta
  Mz                 dBuV           dBuv           a8
  o.179              14.00          sass           054
  0217               2244           s203           3049
  0.304              16.64          4708           a13e
  on                 2151           46.00          2449
  133                16.05          46.00          2005
  24                 17.90          46.00          28.10
  3.035              1483           46.00          arir
  4.105              1528           46.00          30.72
  s.ass              13.03          50.00          acor
  s.e5               1937           50.00          3063
  7.ras              20.63          50.00          2037
  1341               13.80          50.00          3620
  2705               15.00          50.00          aa.01




  * limit exceeded


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500



Line: Neutral




                                          Report no. ETLT150819.0064, Page 18 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




                                          Report no. ETLT150819.0064, Page 19 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                                  FCC ID: VH9KDC500




5.3 Spurious Emissions
       EUT                                    Mobile POS / KDC500 (S/N: N/A)
       Limit apply to                         FCC Part 15.209
       Operating Condition                    RF transmitting continuously during the tested.
       Result                                 Passed

      Limit

       Except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall not
      exceed the field strength levels specified in the following table:

                    Frequencies                                 Field Strength                         Measurement Distance
                       [MHz]                                        [μV/m]                                     [m]

                   0.009 - 0.490                                2 400/F(kHz)                                         300

                   0.490 - 1.705                               24 000/F(kHz)                                         30

                    1.705 - 30.0                                        30                                           30

                       30 - 88                                          100                                          3

                       88 - 216                                         150                                          3

                      216 - 960                                         200                                          3

                     Above 960                                          500                                          3
      * Except as provided in paragraph (g), fundamental emissions from intentional radiators operating
     under this Section shall not be located in the frequency bands 54 MHz - 72 MHz, 76 MHz - 88 MHz,
     174 MHz - 216 MHz or 470 MHz - 806 MHz. However, operation within these frequency bands is
     permitted under other sections of this Part, e.g., Sections 15.231 and 15.241.

      Test Results

      - Refer to see the measured plot in next page.




                                          Report no. ETLT150819.0064, Page 20 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                              ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




Radiated Emissions Test data
- 9 kHz to 30 MHz

       Test Date                               August 26, 2015
       Environmental of Test                   (28.7 ± 0.2) °C, (57 ± 2) % R.H., (100.5 ± 0.0) kPa

     The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.
     Detector mode: CISPR Quasi-Peak mode (100 Hz, 9 kHz)


        Frequency         Reading        Polarization Ant. Factor Cable Loss Result       Limit                         Margin
          [MHz]           [dB(μV)]        (*H/**V)      [dB/m]       [dB]   [dB(μV/m)] [dB(μV/m)]                        [dB]




                                                 Emission attenuated more than
                                              20 dB below the limit are not reported.




     Result: All emissions below noise floor of 20 dB(μV/m).

     NOTES:
                    1.   * H : Horizontal polarization , ** V : Vertical polarization
                    2.   Result = Reading + Antenna factor + Cable loss
                    3.   Margin = Limit - Result
                    4.   The measurement was performed for the frequency range 9 kHz to 30 MHz according to FCC
                         Part 15.209.




                                          Report no. ETLT150819.0064, Page 21 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                              FCC ID: VH9KDC500




- Below 1 GHz (30 MHz to 1 GHz)

     Test Date                              August 26, 2015
     Environmental of Test                  (28.7 ± 0.2) °C, (57 ± 2) % R.H., (100.5 ± 0.0) kPa

    The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.
    Detector mode: CISPR Quasi-Peak mode (6 dB Bandwidth: 120 kHz)


     Frequency Reading Polarization Ant. Factor Cable Loss Height  Result      Limit   Margin
       [MHz]   [dB(μV)] (*H/**V)      [dB/m]     [dB(μV)]   [cm] [dB(μV/m)] [dB(μV/m)] [dB]

        252.64          8.72              V              11.80             2.18            121         22.70         46.00     23.30
        294.07          9.31              V              13.13             2.36            126         24.80         46.00     21.20

    NOTES:
               1.    * H : Horizontal polarization , ** V : Vertical polarization
               2.    Result = Reading + Antenna factor + Cable loss
               3.    Margin value = Limit - Result
               4.    The measurement was performed for the frequency range above 30 MHz according to FCC Part 15.209.




                                          Report no. ETLT150819.0064, Page 22 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                          ETLQP-21-F40-0


                                          FCC TEST REPORT                                                                FCC ID: VH9KDC500




5.4 13.56 MHz carrier field strength within bands
       EUT                               Mobile POS / KDC500 (S/N: N/A)
       Limit apply to                    FCC Part 15.225(a)(b)(c)
       Test Date                         August 26, 2015
       Environmental of Test             (28.6 ± 0.3) °C, (60 ± 2) % R.H., (100.5 ± 0.1) kPa
       Operating Condition               RF transmitting continuously during the tested
       Result                            Passed

                                                Radiated Emission Test Data

      The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.
      Detector mode: CISPR Quasi-Peak mode (6 dB Bandwidth: 9 kHz)

                          Reading                                              Result     Limit
        Frequency                        Polarization Ant. Factor Cable Loss                                                 Margin
                          [dB(μV)                                            [dB(μV/m) [dB(μV/m)
          [MHz]                           (*H/**V)      [dB/m]       [dB]                                                     [dB]
                          @ 3 m]                                               @ 3 m]    @ 3 m]
           13.56            56.70               H               9.10             0.70            66.50          124.00        57.50

      NOTES:
                    1.   * H : Horizontal polarization , ** V : Vertical polarization
                    2.   Result = Reading + Antenna factor + Cable loss
                    3.   Margin value = Limit - Result
                    4.   The measurement was performed for the frequency range 13.56 MHz according to FCC
                         Part 15.225(a)(b)(c)


           [dB(μV/m)]
                130
                120
                110
                100
                 90
                 80
                 70
            Level




                 60
                 50
                 40
                 30
                 20
                 10
                  0
                 13.110             13.250                        13.500                        13.750                      14.010
                                                                     Frequency                                             [M Hz]




                                          Report no. ETLT150819.0064, Page 23 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                            ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




5.5 Occupied Bandwidth

       EUT                                    Mobile POS / KDC500 (S/N: N/A)
       Limit apply to                         FCC Part 15.215
       Test Date                              August 27, 2015
       Environmental of Test                  (23.8 ± 0.0) °C, (48 ± 0) % R.H., (100.5 ± 0.0) kPa
       Operating Condition                    RF transmitting continuously during the tested.
       Result                                 Passed

5.5.1 Occupied Bandwidth

                                                    Frequency              20 dB Bandwidth
                                                      [MHz]                     [kHz]

                                                       13.56                          8.29

      NOTES:
                    1.   Measure frequency separation of relevant channel using spectrum analyzer.



Plots of 20 dB Bandwidth




                                          Report no. ETLT150819.0064, Page 24 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                                FCC ID: VH9KDC500




5.6 Frequency Tolerance

       EUT                               Mobile POS / KDC500 (S/N: N/A)
       Limit apply to                    FCC Part 15.215(e)
       Test Date                         August 27, 2015
       Environmental of Test             (24.3 ± 0.9) °C, (48 ± 3) % R.H., (100.4 ± 0.1) kPa
       Operating Condition               RF transmitting continuously during the tested
       Result                            Passed

                                              Frequency Tolerance Test Data

The Frequency Tolerance of the carrier signal shall be maintained within ± 0.01 % of operating frequency over a
temperature variation of -20 ℃ to +50 ℃ at normal supply voltage, and for a variation in the primary supply voltage
from 85 % to 115 % of the rated supply voltage at a temperature of 20 ℃.

      - Operating frequency: 13.56 MHz
      - Limit: ± 1 356 Hz
      - Within the band: 13.558 644 MHz - 13.561 356 MHz

 Frequency Stability Versus Environment Temperature (+50 ℃ ~ -20 ℃)
                   Reference Frequency: 13.56 MHz                                                       Limit: ± 1 356 Hz

  Environment
                                                         Frequency Measure with Time Elapsed
  Temperature                 Start up                       2 Minute                          5 Minute                    10 Minute
      [℃]
                        MHz          Deviation          MHz         Deviation           MHz          Deviation         MHz         Deviation
        50           13.560 320      0.000 320      13.560 327       0.000 327        13.560 331     0.000 331       13.560 315    0.000 315
        40           13.560 333      0.000 333      13.560 332       0.000 332        13.560 328     0.000 328       13.560 335    0.000 335
        30           13.560 340      0.000 340      13.560 345       0.000 345        13.560 336     0.000 336       13.560 339    0.000 339
        20           13.560 358      0.000 358      13.560 352       0.000 352        13.560 363     0.000 363       13.560 354    0.000 354
        10           13.560 397      0.000 397      13.560 377       0.000 377        13.560 395     0.000 395       13.560 362    0.000 362
         0           13.560 384      0.000 384      13.560 385       0.000 385        13.560 387     0.000 387       13.560 376    0.000 376
        -10          13.560 413      0.000 413      13.560 402       0.000 402        13.560 411     0.000 411       13.560 398    0.000 398
        -20          13.560 446      0.000 446      13.560 399       0.000 399        13.560 437     0.000 437       13.560 461    0.000 461


 Frequency Stability Versus Input Power (± 15 %): Environment Temperature: 25 ℃


                   Reference Frequency: 13.56 MHz                                                       Limit: ± 1 356 Hz

     Power                                               Frequency Measure with Time Elapsed
    Supplied                  Start up                       2 Minute                          5 Minute                    10 Minute
     [Vdc]              MHz          Deviation          MHz         Deviation           MHz          Deviation         MHz         Deviation
      10.80          13.560 357      0.000 357      13.560 352       0.000 352        13.560 361     0.000 361       13.560 373    0.000 373
      12.00          13.560 366      0.000 366      13.560 362       0.000 362        13.560 359     0.000 359       13.560 365    0.000 365
      13.20          13.560 390      0.000 390      13.560 410       0.000 410        13.560 403     0.000 403       13.560 417    0.000 417


                                          Report no. ETLT150819.0064, Page 25 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                               ETLQP-21-F40-0


                                          FCC TEST REPORT                                                            FCC ID: VH9KDC500




6. SAMPLE CALCULATION
   Sample Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor.
      The basic equation with a sample calculation is as follows:

           FS = RA + AF + CF - PA

           Where FS = Field Strength
                 RA = Receiver Amplitude
                 AF = Antenna Factor
                 CF = Cable Attenuation Factor
                 PA* = Preamplifier Factor

           * PA is only be used for the measuring frequency above 1 GHz.

            dB(μV) = 20 log10 (μV) : Equation
            dB(μV) = dBm + 107

   Example         : @ 294.07 MHz


                      Class B Limit             = 46.00 dB(μV/m)

                      Reading                   = 9.31 dB(μV)

                      Antenna Factor + (Cable Loss)                                   = 13.13 + 2.36 = 15.49 dB(μV/m)

                                      Total                                           = 24.80 dB(μV/m)

                      Margin                    = 46.00 – 24.80 = 21.20 dB

                                                = 21.20 dB below Limit




                                          Report no. ETLT150819.0064, Page 26 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                        ETLQP-21-F40-0


                                          FCC TEST REPORT                                                              FCC ID: VH9KDC500




7. List of test equipments used for measurements
                                                                                                                                  Cal. Due
             Test Equipment                          Model                      Mfg.                 Serial No.      Cal. Date
                                                                                                                                   Date

               EMI Test Receiver                   ESVS 10                      R&S                 835165/001       15.03.17     16.03.17

               EMI Test Receiver                    ESCS30                      R&S                 847793/005       15.03.17     16.03.17

              Two-Line V-Network                    ENV216                      R&S                 958599/106       15.03.16     16.03.16

                       LISN                          3816-2                    EMCO                     1002         15.04.22     16.04.22

                 Loop Antenna                         6502                     EMCO                  00033743        14.09.23     16.09.23

              LogBicon Antenna                    VULB9160                Schwarzbeck                   3164         15.06.08     17.06.08

               DC Power Supply                      E3630A                    Agilent              MY40006360        15.09.04     16.09.04

                   Turn-Table                      TT 1.35 SI                   SES                        -           N/A           N/A

                Antenna Master                       AM 4.5                     SES                        -           N/A           N/A

          Constant TEMP.&HUMID.
                                                    PL-1KP              Tabai Espec Corp.            14006754        15.03.16     16.03.16
                 Chamber




                                          Report no. ETLT150819.0064, Page 27 of 27
Head Office: #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea    Tel : 82-2-858-0786   Fax : 82-2-858-0788
Open site: #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea                                              ETLQP-21-F40-0



Document Created: 2015-09-11 16:11:43
Document Modified: 2015-09-11 16:11:43