Test Report

FCC ID: VG8XM134AYY

Test Report

Download: PDF
FCCID_1289811

                       FCC PART 18
             EMI MEASUREMENT AND TEST REPORT
                                                              For

                   Foshan Shunde Midea Microwave and Electrical
                              Appliances Manufacturing Co., Ltd.

                                     NO.18 Huanzhen West Road, Beijiao,
                                   Shunde, Foshan, Guangdong, China 528311


                                    FCC ID: VG8XM134AYY


               Report Type:                                   Product Type:
               Original Report                                Microwave Oven




                        Test Engineer:        Jessica He

                           Report No.:        RSZ10031551

                          Report Date:        2010-05-28

                                              Lisa Zhu

                         Reviewed By:         EMC Engineer

                        Prepared By:          Bay Area Compliance Laboratories Corp. (Shenzhen)
                                              6/F, the 3rd Phase of WanLi Industrial Building,
                                              ShiHua Road, FuTian Free Trade Zone
                                              Shenzhen, Guangdong, China
                                              Tel: +86-755-33320018
                                              Fax: +86-755-33320008




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the
customer to claim product certification, approval, or endorsement by NVLAP*, NIST, or any agency of the Federal Government.
* This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “*” (Rev.2)


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.                                                       FCC ID: VG8XM134AYY




                                                           TABLE OF CONTENTS

GENERAL INFORMATION.......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................3
OPERATING CONDITION/TEST CONFIGURATION..........................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  EXTERNAL CABLE LIST AND DETAILS .........................................................................................................................5
  CONFIGURATION OF TEST SETUP .................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................5
CONDUCTED EMISSIONS ........................................................................................................................................6
 MEASUREMENT UNCERTAINTY ....................................................................................................................................6
 EUT SETUP ..................................................................................................................................................................6
 EMI TEST RECEIVER SETUP .........................................................................................................................................7
 TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................7
 TEST PROCEDURE ........................................................................................................................................................7
 TEST RESULTS SUMMARY ............................................................................................................................................7
 TEST DATA ..................................................................................................................................................................7
RADIATION HAZARD MEASUREMENT.............................................................................................................10
  ENVIRONMENTAL CONDITIONS ..................................................................................................................................10
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................10
  RADIATION HAZARD MEASUREMENT ........................................................................................................................10
  INPUT POWER .............................................................................................................................................................11
  LOAD FOR MICROWAVE OVENS .................................................................................................................................11
  RF OUTPUT POWER MEASUREMENT ..........................................................................................................................12
  OPERATING FREQUENCY MEASUREMENT ..................................................................................................................13
RADIATED EMISSIONS...........................................................................................................................................16
  MEASUREMENT UNCERTAINTY ..................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  EMI TEST RECEIVER SETUP AND SPECTRUM ANALYZER SETUP................................................................................16
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................17
  TEST RESULTS SUMMARY ..........................................................................................................................................17
  TEST DATA AND PLOTS ..............................................................................................................................................18




Report #: RSZ10031551                                                           Page 2 of 19                                          FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.    FCC ID: VG8XM134AYY

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)
The Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.’s model:
EM134AMV (FCC ID: VG8XM134AYY) or the “EUT” as referred to in this report is a Microwave Oven
which measures approximately 51.5cm L x 40.0cm W x 29.5cm H, rated input voltage: AC 120 V/60 Hz.

*Note: The series products, model XM134AYY, more detail description as follows:
1. where YY is alphabetic characters. YY: Suffix could be from 0 to 9 or from A to Z (Cosmetic Design).
2. X=E, E: Touch Pad type.

* All measurement and test data in this report was gathered from production sample serial number:
1003516 (Assigned by BACL, Shenzhen). The EUT was received on 2010-03-15.


Objective
The following test report is prepared on behalf of Foshan Shunde Midea Microwave and Electrical
Appliances Manufacturing Co., Ltd. in accordance with Part 2, Subpart J, and Part 18, Subparts A, B and C
of the Federal Communication Commissions rules and regulations.

The objective of the manufacturer is to determine compliance with FCC Part 18 limits.


Related Submittal(s)/Grant(s)
No related submittal(s).


Test Methodology
All measurements contained in this report were conducted with MP-5, FCC Methods of Measurements of
Radio Noise Emissions from ISM Equipment, February 1986. All measurements were performed at Bay
Area Compliance Laboratory Corporation. The radiated testing was performed at an antenna-to-EUT
distance of 3 meters.


Test Facility

The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located in
the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen,
Guangdong, China.

Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been
found to be in compliance with the requirements of Section 2.948 of the FCC Rules on November 21,
2007. The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI
C63.4-2003.




Report #: RSZ10031551                             Page 3 of 19                      FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.   FCC ID: VG8XM134AYY


The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.

Additionally, Bay Area Compliance Laboratories Corp. (Shenzhen) is a National Institute of Standards and
Technology (NIST) accredited laboratory, under the National Voluntary Laboratory Accredited Program
(Lab Code 200707-0).




The current scope of accreditations can be found at http://ts.nist.gov/Standards/scopes/2007070.htm




Report #: RSZ10031551                            Page 4 of 19                     FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.           FCC ID: VG8XM134AYY

OPERATING CONDITION/TEST CONFIGURATION
Justification
The EUT was provided for tests as a stand-alone device. It was prepared for testing in accordance with the
manufacturer’s instructions. The EUT was operated at maximum (continuous) RF output power. The loads
consisted of water in a glass beaker in the amounts specified in the test procedure.


Equipment Modifications
No modifications were made to the unit tested.


External Cable List and Details

                 Cable Description                   Length (m)               From/Port           To


         Unshield Undetachable AC Power Cable            1.3                    EUT              LISN



Configuration of Test Setup




Block Diagram of Test Setup


                                                               LISN



                                        EUT
                                                                  1.0 Meter




             Non-Conducting Table
             80 cm above Ground Plane


                                 1.5 Meters


Report #: RSZ10031551                            Page 5 of 19                             FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.   FCC ID: VG8XM134AYY

CONDUCTED EMISSIONS
Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, and LISN.

Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the
uncertainty of any conducted emissions measurement at Bay Area Compliance Laboratories Corp.
(Shenzhen) is +2.4 dB.


EUT Setup




The setup of EUT is according with per MP-5: 1986 measurement procedure. Specification used was with
the FCC Part 18.

The EUT was connected to a 120 VAC/ 60Hz power source.




Report #: RSZ10031551                            Page 6 of 19                      FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.        FCC ID: VG8XM134AYY


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

        Frequency Range                           IF B/W
       150 kHz – 30 MHz                            9 kHz


Test Equipment List and Details

                                                                     Serial      Calibration    Calibration
      Manufacturer            Description           Model
                                                                    Number          Date         Due Date

     Rohde & Schwarz      EMI Test Receiver        ESCS30          830245/006     2009-04-28     2010-04-27

     Rohde & Schwarz            L.I.S.N.           ESH2-Z5         892107/021     2009-04-28     2010-04-27


    * Com-Power’s LISN were used as the supporting equipment.
    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations
    have been performed in accordance to NVLAP requirements, traceable to the NIST.


Test Procedure
During the conducted emission test, the EUT power cord was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 18, with the worst
margin reading of:


                            21.36 dB at 0.150 MHz in the Line conductor mode
                           19.11 dB at 0.160 MHz in the Neutral conductor mode


Test Data
     Environmental Conditions

            Temperature:               25° C
       Relative Humidity:               48%
          ATM Pressure:               100.2kPa

    The testing was performed by Jessica He on 2010-03-18.
    Test Mode: Running (Max Power)


Report #: RSZ10031551                               Page 7 of 19                        FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.   FCC ID: VG8XM134AYY



120V/60Hz, Line:




                          Correction        Cord.
          Frequency                                           Limit      Margin
                           Factor           Result                                    Remark
            (MHz)                                            (dBµV)       (dB)
                            (dB)           (dBµV)
             0.150           10.10          44.64             66.00       21.36          QP
             0.350           10.10          29.23             59.07       29.84          QP
             0.440           10.10          26.44             57.09       30.65          QP
            29.930           10.30          15.70             48.00       32.30          QP
             0.350           10.10          12.12             49.07       36.95          AV
             0.150           10.10          18.04             56.00       37.96          AV
             0.440           10.10           8.13             47.09       38.96          AV
            24.790           10.30          11.01             50.00       38.99          AV
            24.790           10.30          19.92             60.00       40.08          QP
            29.770           10.30           9.62             50.00       40.38          AV
            26.000           10.30           8.29             50.00       41.71          AV
            26.230           10.30          14.82             60.00       45.18          QP




Report #: RSZ10031551                               Page 8 of 19                  FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.   FCC ID: VG8XM134AYY


120V/60Hz, Neutral:




                          Correction        Cord.
          Frequency                                           Limit      Margin
                           Factor           Result                                    Remark
            (MHz)                                            (dBµV)       (dB)
                            (dB)           (dBµV)
             0.160           10.10          46.45             65.56       19.11          QP
            24.210           10.30          26.36             50.00       23.64          AV
             0.560           10.10          21.67             56.00       34.33          QP
             1.230           10.10          11.65             46.00       34.35          AV
             0.160           10.10          20.21             55.56       35.35          AV
             0.560           10.10           9.93             46.00       36.07          AV
            24.240           10.30          19.18             60.00       40.82          QP
            27.640           10.30          19.18             60.00       40.82          QP
            28.640           10.30           8.60             50.00       41.40          AV
            27.640           10.30           8.13             50.00       41.87          AV
             1.220           10.10          12.19             56.00       43.81          QP
            28.680           10.30          11.89             60.00       48.11          QP




Report #: RSZ10031551                               Page 9 of 19                  FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.        FCC ID: VG8XM134AYY

RADIATION HAZARD MEASUREMENT
Environmental Conditions

            Temperature:               25° C
       Relative Humidity:               56%
          ATM Pressure:               100.2kPa


Test Equipment List and Details

                                                                      Serial     Calibration    Calibration
       Manufacturer            Description           Model
                                                                     Number         Date         Due Date
     Rohde & Schwarz        EMI Test Receiver         ESCI            100035      2009-11-24     2010-11-24
       Sunol Sciences         Horn Antenna          DRH-118          A052604      2009-05-05     2010-05-04
            HP                Preamplifier           8449B          3008A00277    2009-09-12     2010-09-11
                             Digital Power
           Ainuo                                     8732B          028706117     2009-12-23     2010-12-23
                               Analyzer
            HY              AC Power Source         9020117          GY053(1)     2009-08-21     2010-08-21
          Holday              Leakage Meter         HI-1710          05/2731      2009-06-02     2010-06-02

    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations
    have been performed in accordance to NVLAP requirements, traceable to the NIST.


Radiation Hazard Measurement
Radiation leakage was measured in the as-received condition with the oven door closed using a microwave
leakage meter.

A 1000ml water load was placed in the center of the oven and the oven was operated at maximum output
power.

   There was no microwave leakage exceeding a power level of 0.71mW/cm2 observed at any point 5cm
or more from the external surface of the oven.

A maximum of 1.0mW/cm2 is allowed in accordance with the applicable Federal Standards. Hence,
microwave leakage in the as-received condition with the oven door closed was below the maximum
allowed.




Report #: RSZ10031551                               Page 10 of 19                        FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.      FCC ID: VG8XM134AYY

Input Power
Input power and current was measured using a power analyzer. A 1000ml water load was placed in the
center of the oven and the oven was operated at maximum output power. A 1000ml water load was chosen
for its compatibility with the procedure commonly used by manufacturers to determine their input ratings.


           Input Voltage        Input Current       Measured Input Power          Rated Input Power
             (Vac/Hz)              (Amps)                 (Watts)                      (Watts)
               120/60                13.05                   1567                       1500

    Based on the measured input power, the EUT was found to be operating within the intended
specifications.


Load for Microwave Ovens
For all measurements, the energy developed by the oven was absorbed by a dummy load consisting of a
quantity of tap water in a beaker. If the oven was provided with a shelf or other utensil support, this
support was in its initial normal position. For ovens rated at 1000 watts or less power output, the beaker
contained quantities of water as listed in the following subparagraphs. For ovens rated at more than
1000watts output, each quantity was increased by 50% for each 500watts or fraction thereof in excess of
1000watts. Additional beakers were used if necessary.

● Load for power output measurement: 1000 milliliters of water in the beaker located in the center of the
oven.

● Load for frequency measurement: 1000 milliliters of water in the beaker located in the center of the
oven.

● Load for measurement of radiation on second and third harmonic: Two loads, one of 700 and the other
of 300 milliliters, of water are used. Each load is tested both with the beaker located in the center of the
oven and with it in the right front corner.


The RF output power is rated at 1000 watts

     Load used for power output measurement = 1000 milliliters of water
     Load used for frequency measurement = 1000 milliliters of water
     Load used for harmonic measurement = 700 & 300 milliliters of water
     Load used for other measurement = 700 milliliters of water




Report #: RSZ10031551                             Page 11 of 19                        FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.     FCC ID: VG8XM134AYY


RF Output Power Measurement
The Caloric Method was used to determine maximum RF output power. The initial temperature of the
water load was measured. The water load was placed in the center of the oven. The oven was operated at
maximum output power for 200 seconds, the temperature of the water was re-measured.


      Quality of Water         Starting Temperature         Final Temperature          Elapsed Time
            (ml)                        (ºC)                       (ºC)                     (s)

             1000                       20                         59.9                      200


    Power = (4.2 joules/calorie) (volume in milliliters) (temperature rise)/ (time is seconds)
    Power = 4.2 joules/calorie x 1000 x (59.9-20) / 200
    Power = 837.9 watts


   The measurement output power was found to be less than 500watts. Therefore, in accordance with
Section 18.305 of Subpart-C, the measured out-of-band emissions were compared to the limit of
25μV/meter at a 300-meter measurement distance.


    The measured output power was found to exceed 500watts. Therefore, in accordance with Section
18.305 of Subpart-C, the measured out-of-band emissions were compared with the limit calculated as
following:

                    LFS = 25*SQRT (Power Output/500)
                    LFS = 25*SQRT (837.9/500)
                    LFS ≈ 32.4

Where: LFS is the maximum allowable field strength for out-of-band emissions in μV/meter at a 300-
meter measurement distance. Power Output is the measured output power in watts.


          Manufacturer                  Model            LFS         dBμV/m@300m           dBμV/m@3m

     Foshan Shunde Midea
    Microwave and Electrical
                                     EM134AMV            32.4              30.2                  70.2
    Appliances Manufacturing
            Co., Ltd.




Report #: RSZ10031551                             Page 12 of 19                       FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.     FCC ID: VG8XM134AYY


Operating Frequency Measurement
    Variation in Operating Frequency with Time

The operating frequency was measured using a spectrum analyzer. Starting with the EUT at room
temperature, a 1000ml water load was placed in the center of the oven and the oven was operated at
maximum output power. The fundamental operating frequency was monitored until the water load was
reduced to 20 percent of the original load.

The results of this test are as follows:

                                                          Minimum Frequency       Maximum Frequency
                Manufacturer                Model
                                                               (MHz)                   (MHz)
           Foshan Shunde Midea
          Microwave and Electrical
                                           EM134AMV                 2471.9             2477.8
          Appliances Manufacturing
                  Co., Ltd.

Refer to data pages for details of the variation in operating frequency with time measurement.




Report #: RSZ10031551                               Page 13 of 19                    FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.     FCC ID: VG8XM134AYY




     Variation in Operating Frequency with Line Voltage

The EUT was operated / warmed by at least 10 minutes of use with a 1000ml water load at room
temperature at the beginning of the test. Then the operating frequency was monitored as the input voltage
was varied between 80 and 125 percent of the nominal rating.

The results of this test are as follows:

Line voltage varied from 96Vac to 150Vac.


                                                          Minimum Frequency       Maximum Frequency
                Manufacturer                Model
                                                               (MHz)                   (MHz)
           Foshan Shunde Midea
          Microwave and Electrical
                                           EM134AMV                 2467.9              2482.0
          Appliances Manufacturing
                  Co., Ltd.

Please refer to following pages for details of the variation in operating frequency with line voltage
measurement.




Report #: RSZ10031551                               Page 14 of 19                     FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.   FCC ID: VG8XM134AYY




Report #: RSZ10031551                            Page 15 of 19                     FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.     FCC ID: VG8XM134AYY

RADIATED EMISSIONS
Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.

Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the
uncertainty of a radiation emissions measurement at Bay Area Compliance Laboratories Corp. (Shenzhen)
is +4.0 dB.


EUT Setup




The radiated emission tests were performed in the 3 meters chamber A test site, using the setup accordance
with the FCC MP - 5. The specification used was the FCC part 18 limits.

The EUT was connected to 120 VAC/60 Hz power source.


EMI Test Receiver Setup and Spectrum Analyzer Setup
The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver and Spectrum Analyzer were set with the
following configurations:

        Frequency Range          R B/W          Video B/W         IF B/W
       30 – 1000 MHz            100 kHz         300 kHz           120 kHz
        Above 1GHz               1MHz             10Hz
Report #: RSZ10031551                             Page 16 of 19                      FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.        FCC ID: VG8XM134AYY

Test Equipment List and Details

                                                                                   Calibration    Calibration
     Manufacturer           Description            Model         Serial Number
                                                                                      Date         Due Date

           HP                Amplifier           HP8447D            2944A09795     2009-08-02     2010-08-02
    Rohde & Schwarz      EMI Test Receiver         ESCI               100035       2009-11-07     2010-11-06
     Sunol Sciences     Broadband Antenna           JB1             A040904-1      2010-03-11     2011-03-11
     Sunol Sciences      System Controller        SC99V              041304-1          N/A            N/A
      A.H. System          Horn Antenna        SAS-200/571             135         2009-05-17     2010-05-17
    Rohde & Schwarz      Spectrum Analyzer        FSEM30            849720/019     2009-07-08     2010-07-08

    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations
    have been performed per the NVLAP requirements, traceable to NIST.


Test Procedure
For the radiated emissions test, the EUT power cord was connected to the AC floor outlet.

Maximizing procedure was performed on the six (6) highest emissions to ensure that the EUT complied
with all installation combinations.

The EUT was in the normal (naïve) operating mode during the final qualification test to represent the
worst results.

All data was recorded in the Quasi-peak detection mode from 30 MHz to 1 GHz and average detection
mode above 1GHz.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude

Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 18, with the worst
margin reading of:


                    27.3 dB at 45.762500 MHz in the Vertical polarization, below 1GHz
                    8.61 dB at 9917.0 MHz in the Horizontal polarization, above 1GHz




Report #: RSZ10031551                               Page 17 of 19                        FCC Part 18 Test Report


Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.       FCC ID: VG8XM134AYY

Test Data and Plots
     Environmental Conditions

            Temperature:              25° C
       Relative Humidity:              56%
          ATM Pressure:              100.2kPa

    The testing was performed by Jessica He on 2010-03-24.

    Test Mode: Running (Max Power)


     Below 1 GHz:




                   Corrected      Antenna       Antenna      Turntable   Correction
    Frequency                                                                           Limit      Margin
                   Amplitude       Height       Polarity      Position    Factor
      (MHz)                                                                           (dBµV/m)      (dB)
                   (dBµV/m)         (cm)         (H/V)         (deg)       (dB)
    45.762500         42.9          135.0          V            3.0        -10.5         70.2       27.30
    948.872000        42.3          130.0          H           172.0        -0.5         70.2       27.90
    96.664500         36.5          101.0          V           82.0        -18.2         70.2       33.70
    35.793250         35.3          179.0          V           165.0       -10.4         70.2       34.90
    31.947750         33.2          317.0          H           141.0        -7.5         70.2       37.00
    254.312500        31.2          100.0          V            0.0        -14.3         70.2       39.00




Report #: RSZ10031551                             Page 18 of 19                        FCC Part 18 Test Report


  Foshan Shunde Midea Microwave and Electrical Appliances Manufacturing Co., Ltd.         FCC ID: VG8XM134AYY


          Above 1 GHz:

                S.A.                  Turntable           Test Antenna      Cable Pre-  Cord.      FCC Part 18
Frequency                  Detector
              Reading                 Direction                             Loss Amp.   Amp.
  MHz                    (PK/QP/AV)               Height     Polar   Factor                      Limit    Margin
             (dBµV/m)                 (Degree)                              (dB) (dB) (dBμV/m)
                                                   (m)       (H/V)    (dB)                     (dBµV/m)     (dB)
 9917.0        39.35        AV           54        1.10        H     41.50   6.22 25.48    61.59      70.2      8.61
 4934.3        47.14        AV           0         1.34        H     36.60   4.37 26.58    61.53      70.2      8.67
 4934.3        48.02        AV          360        1.06        V     35.40   4.37 26.58    61.21      70.2      8.99
 9917.0        37.84        AV           66        1.06        V     40.40   6.22 25.48    58.98      70.2      11.22
 8390.8        38.58        AV          307        1.31        H     40.40   5.61 27.66    56.93      70.2      13.27
 7358.3        37.88        AV          202        1.10        V     38.10   5.20 27.49    53.69      70.2      16.51
 8390.8        35.68        AV           63        1.08        V     39.30   5.61 27.66    52.93      70.2      17.27
 7403.2        35.37        AV           18        1.11        H     39.40   5.20 27.49    52.48      70.2      17.72




                                      ***** END OF REPORT *****




  Report #: RSZ10031551                             Page 19 of 19                          FCC Part 18 Test Report



Document Created: 2010-06-02 16:02:43
Document Modified: 2010-06-02 16:02:43

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC