DCD Test Report

FCC ID: V65E6910

Test Report

Download: PDF
FCCID_4038241

                                                               FCC Test Report

                       Report No.: RF180821C20-4

                            FCC ID: V65E6910

                       Test Model: E6910

                 Received Date: Aug. 21, 2018

                         Test Date: Sep. 18, 2018

                     Issued Date: Sep. 25, 2018


                         Applicant: Kyocera Corporation c/o Kyocera International, Inc.

                          Address: 8611 Balboa Avenue, San Diego, CA 92123



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 ( R.O.C )
             Test Location (1): No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan
                                Hsien 333, Taiwan, R.O.C.
            FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.




Report No.: RF180821C20-4                                            Page No. 1 / 25                                            Report Format Version: 6.1.1


                                                                Table of Contents
Release Control Record .................................................................................................................................. 3
1 Certificate of Conformity ........................................................................................................................... 4
2 Summary of Test Results ........................................................................................................................... 5
    2.1 Measurement Uncertainty ..................................................................................................................... 5
    2.2 Modification Record .............................................................................................................................. 5
3 General Information ................................................................................................................................... 6
    3.1 General Description of EUT .................................................................................................................. 6
    3.2 Description of Test Modes..................................................................................................................... 7
        3.2.1 Test Mode Applicability and Tested Channel Detail .................................................................... 7
    3.3 Description of Support Units ................................................................................................................. 8
        3.3.1 Configuration of System under Test ........................................................................................... 8
    3.4 General Description of Applied Standards ............................................................................................ 8
4 Test Types and Results .............................................................................................................................. 9
    4.1 Radiated Emission and Bandedge Measurement ................................................................................ 9
        4.1.1 Limits of Radiated Emission and Bandedge Measurement ....................................................... 9
        4.1.2 Test Instruments ....................................................................................................................... 10
        4.1.3 Test Procedures ......................................................................................................................... 11
        4.1.4 Deviation from Test Standard .................................................................................................... 11
        4.1.5 Test Setup ................................................................................................................................. 12
        4.1.6 EUT Operating Conditions ........................................................................................................ 12
        4.1.7 Test Results .............................................................................................................................. 13
    4.2 Conducted Emission Measurement .................................................................................................... 19
        4.2.1 Limits of Conducted Emission Measurement ........................................................................... 19
        4.2.2 Test Instruments ....................................................................................................................... 19
        4.2.3 Test Procedures ........................................................................................................................ 20
        4.2.4 Deviation from Test Standard ................................................................................................... 21
        4.2.5 Test Setup ................................................................................................................................. 21
        4.2.6 EUT Operating Conditions ........................................................................................................ 21
        4.2.7 Test Results .............................................................................................................................. 22
5 Pictures of Test Arrangements................................................................................................................ 24
Appendix – Information on the Testing Laboratories ................................................................................ 25




Report No.: RF180821C20-4                                         Page No. 2 / 25                                          Report Format Version: 6.1.1


                                           Release Control Record


 Issue No.              Description                                       Date Issued
 RF180821C20-4          Original Release                                  Sep. 25, 2018




Report No.: RF180821C20-4                     Page No. 3 / 25       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Smart Phone

              Brand: Kyocera

        Test Model: E6910

    Sample Status: Identical Prototype

          Applicant: Kyocera Corporation c/o Kyocera International, Inc.

          Test Date: Sep. 18, 2018

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.209)
                        ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                             ,   Date:        Sep. 25, 2018
                               Ivonne Wu / Supervisor




     Approved by :                                              ,   Date:        Sep. 25, 2018
                            Dylan Chiou / Project Engineer




Report No.: RF180821C20-4                     Page No. 4 / 25                         Report Format Version: 6.1.1


2     Summary of Test Results

                                 47 CFR FCC Part 15, Subpart C (Section 15.209)

    FCC Clause                     Test Item                    Result                      Remarks
                                                                             Meet the requirement of limit.
      15.207                Conducted emission test                 Pass     Minimum passing margin is —14.34 dB
                                                                             at 0.48626 MHz.
                                                                             Meet the requirement of limit.
      15.209                 Radiated emission test                 Pass     Minimum passing margin is —9.16 dB at
                                                                             33.88 MHz.


2.1    Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16—4—2:


                    M               T                                F                      Expended Uncertainty
                        easuremen                                        requenc
                                                                           Mss                      (k=2) )
        Conducted Emissions at mains ports                     150 kHz ~ 30 MHz                      2.44 dB

                                                               30 MHz ~ 200 MHz                      2.93 dB
          Radiated Emissions up to 1 GHz
                                                             200 MHz ~ 1000 MHz                      2.95 dB


2.2    Modification Record
There were no modifications required for compliance.




Report No.: RF180821C20—4                         Page No. 5 / 25                             Report Format Version: 6.1.1


3     General Information
3.1    General Description of EUT

 Product                      Smart Phone
 Brand                        Kyocera
 Test Model                   E6910
 Status of EUT                Identical Prototype
                              3.8 Vdc (Battery)
 Power Supply Rating          5 Vdc or 9 Vdc or 12 Vdc (Adapter)
                              5 Vdc (Host equipment)
 Operating Frequency          150 kHz
 Antenna Connector            N/A
 Accessory Device             Refer to Note as below
 Data Cable Supplied          Refer to Note as below
Note:
1. The EUT’s accessories list refers to Ext. Pho.
2. The above EUT information is declared by manufacturer and for more detailed features description,
   please refers to the manufacturer's specifications or user's manual.




Report No.: RF180821C20-4                     Page No. 6 / 25                      Report Format Version: 6.1.1


3.2      Description of Test Modes

1 channel is provided to this EUT:
          Channel                                                    Frequency (kHz)
                1                                                              150


3.2.1        Test Mode Applicability and Tested Channel Detail

EUT Configure                         Applicable To
                                                                                               Description
    Mode                     RE<1G                      PLC

         A                     √                           √              Charging Mode

         B                     √                           -              Standby Mode
Where               RE<1G: Radiated Emission below 1 GHz                  PLC: Power Line Conducted Emission


Radiated Emission Test (Below 1 GHz):
   Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
      available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
             EUT Configure Mode                         Available Channel                           Tested Channel

                      A, B                                       1                                           1



Power Line Conducted Emission Test:
  Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
      available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
             EUT Configure Mode                         Available Channel                           Tested Channel

                       A                                         1                                           1



Test Condition:

      Applicable To            Environmental Conditions                    Input Power                       Tested By

           RE                      25 deg. C, 65 % RH                     120 Vac, 60 Hz                 Jisyong Wang

          PLC                      25 deg. C, 65 % RH                     120 Vac, 60 Hz                 Jisyong Wang




Report No.: RF180821C20-4                               Page No. 7 / 25                               Report Format Version: 6.1.1


3.3      Description of Support Units

The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
 No.            Product                 Brand              Model No.            Serial No.             FCC ID
  A.           Earphone                 Funkey              FK130102               N/A                   N/A
  B.     Wireless Charger PAD             LG                WCP-300                N/A                   N/A

 No.                                   Signal Cable Description Of The Above Support Units
 1.     N/A
 2.     N/A
Note:
1. All power cords of the above support units are non-shielded (1.8m).


3.3.1     Configuration of System under Test




                                        Wireless          EUT
                                        Charger
                                                 (Power from AC Adapter)
                                                                            Earphone


          *Test Table



3.4      General Description of Applied Standards

The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:


FCC Part 15, Subpart C (15.209)
ANSI C63.10-2013


All test items have been performed and recorded as per the above standards.




Report No.: RF180821C20-4                                 Page No. 8 / 25                    Report Format Version: 6.1.1


4      Test Types and Results
4.1      Radiated Emission and Bandedge Measurement
4.1.1     Limits of Radiated Emission and Bandedge Measurement

              Frequencies                        Field Strength                 Measurement Distance
                 (MHz)                         (microvolts/meter)                     (meters)
             0.009 ~ 0.490                        2400/F (kHz)                             300
             0.490 ~ 1.705                       24000/F (kHz)                             30
              1.705 ~ 30.0                              30                                 30
                 30 ~ 88                               100                                  3
                88 ~ 216                               150                                  3
               216 ~ 960                               200                                  3
               Above 960                               500                                  3
NOTE:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
3. For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the
      peak field strength of any emission shall not exceed the maximum permitted average limits, specified
      above by more than 20 dB under any condition of modulation.




Report No.: RF180821C20-4                       Page No. 9 / 25                        Report Format Version: 6.1.1


4.1.2    Test Instruments

        Description &                                                      Date of               Due Date of
                                  Model No.              Serial No.
        Manufacturer                                                      Calibration            Calibration
Test Receiver
                                   N9038A             MY51210203         Mar. 16, 2018          Mar. 15, 2019
Agilent
Spectrum Analyzer
                                   N9010A             MY52220314        Nov. 24, 2017           Nov. 23, 2018
Agilent
Spectrum Analyzer
                                   FSU43                  101261         Jan. 11, 2018          Jan. 10, 2019
ROHDE & SCHWARZ
BILOG Antenna
                                 VULB 9168               9168-472       Dec. 06, 2017           Dec. 05, 2018
SCHWARZBECK
Loop Antenna                      EM-6879                   269         Sep. 07, 2018           Sep. 06, 2019
Preamplifier
                                 EMC001340                980201        Nov. 01, 2017           Oct. 30, 2018
EMCI
Preamplifier
                                 EMC 330H                 980112         Oct. 13, 2017          Oct. 12, 2018
EMCI
Power Sensor
                                  MA2411B                1315050        Sep. 04, 2018           Sep. 03, 2019
Anritsu
RF Coaxial Cable
                                    8D-FB            Cable-Ch10-01       Oct. 20, 2017          Oct. 19, 2018
Worken
Boresight Antenna Fixture          FBA-01                FBA-SIP01            NA                       NA
Software                             E3
                                                            NA                NA                       NA
BV ADT                            6.120103
Antenna Tower
                                  MFA-440H                  NA                NA                       NA
MF
Turn Table
                                 MFT-201SS                  NA                NA                       NA
MF
Antenna Tower &Turn
Table Controller                  MF-7802                   NA                NA                       NA
MF


Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
        2. The test was performed in HwaYa Chamber 10.
        3. The horn antenna and preamplifier (model: EMC 184045) are used only for the measurement of
           emission frequency above 1GHz if tested.
        4. The IC Site Registration No. is IC7450F-10.




Report No.: RF180821C20-4                      Page No. 10 / 25                          Report Format Version: 6.1.1


4.1.3    Test Procedures

For Radiated Emission below 30 MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
     room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c. Both Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
     measurement.
d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
     from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with Maximum
     Hold Mode.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9 kHz at frequency
     below 30 MHz.


For Radiated Emission above 30 MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at 3 meter chamber room
     for test. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c. The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
     heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
     the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
     hold mode when the test frequency is below 1 GHz.
f.   The test-receiver system was set to peak and average detected function and specified bandwidth with
     maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
     Quasi-peak detection (QP) at frequency below 1 GHz.
2. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
     for Peak detection (PK) at frequency above 1 GHz.
3. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is ≥ 1/T
     (Duty cycle < 98 %) or 10 Hz (Duty cycle ≥ 98 %) for Average detection (AV) at frequency above 1 GHz.
4. All modes of operation were investigated and the worst-case emissions are reported.


4.1.4    Deviation from Test Standard

No deviation.




Report No.: RF180821C20-4                       Page No. 11 / 25                         Report Format Version: 6.1.1


4.1.5   Test Setup
  <Radiated Emission below 30 MHz>


                                                                                   1m
            EUT&                               3m
            Support Units

                                    Turn Table

               80 cm


                                            Ground Plane
                                            Test Receiver




  <Radiated Emission 30 MHz to 1 GHz>

                                                               Ant. Tower
                                                                                      1-4m
                                                                                      Variable
                                               3m
                                                10m
              EUT&
              Support Units

                                         Turn Table

                  80cm


                                              Ground Plane

                                              Test Receiver




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions

Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF180821C20-4                       Page No. 12 / 25                           Report Format Version: 6.1.1


4.1.7     Test Results
<Charging Mode>
EUT Test Condition                                             Measurement Detail

 Input Power                      120 Vac, 60 Hz               Frequency Range                 0.009 ~ 30 MHz
Environmental                                                                                  Average
                                  25 deg. C, 65 % RH           Detector Function
Conditions                                                                                     Quasi-Peak
Tested By                         Jisyong Wang


                                   Antenna Polarity & Test Distance: Open at 3 m
            Emission      Read                            Antenna                   Preamp   Antenna        Table
Frequency                             Limit    Margin                     Cable
              Level       Level                            Factor                   Factor    Height       Angle      Remark
  (MHz)                             (dBuV/m)    (dB)                    Loss (dB)
            (dBuV/m)     (dBuV)                            (dB/m)                    (dB)      (cm)       (Degree)
  0.147       80.86      101.49      104.26      -23.4     20.31          0.02      40.96      100           360      Average
  0.294       60.18      80.69       98.24     -38.06      20.27          0.02       40.8      100           360      Average
  0.441       54.13      74.51       94.72     -40.59      20.26          0.05      40.69      100           360      Average
  0.588       51.44      71.78       72.22     -20.78      20.25          0.08      40.67      100           360         QP
  0.735       47.43      67.77       70.28     -22.85      20.26           0.1       40.7      100           360         QP
  0.882       48.85      69.19       68.69     -19.84      20.27          0.12      40.73      100           360         QP
  1.029       44.54      64.88       67.36     -22.82      20.27          0.13      40.74      100           360         QP
                                   Antenna Polarity & Test Distance: Close at 3 m
            Emission      Read                            Antenna                   Preamp   Antenna        Table
Frequency                             Limit    Margin                     Cable
              Level       Level                            Factor                   Factor    Height       Angle      Remark
  (MHz)                             (dBuV/m)    (dB)                    Loss (dB)
            (dBuV/m)     (dBuV)                            (dB/m)                    (dB)      (cm)       (Degree)
  0.147       77.81      98.44       104.26    -26.45      20.31          0.02      40.96      100            0       Average
  0.294       60.93      81.44       98.24     -37.31      20.27          0.02       40.8      100            0       Average
  0.441       56.52       76.9       94.72       -38.2     20.26          0.05      40.69      100            0       Average
  0.588       49.89      70.23       72.22     -22.33      20.25          0.08      40.67      100            0          QP
  0.735       49.18      69.52       70.28       -21.1     20.26           0.1       40.7      100            0          QP
  0.882       46.72      67.06       68.69     -21.97      20.27          0.12      40.73      100            0          QP
  1.029       43.91      64.25       67.36     -23.45      20.27          0.13      40.74      100            0          QP
                            Antenna Polarity & Test Distance: Ground-parallel at 3 m
            Emission      Read                            Antenna                   Preamp   Antenna        Table
Frequency                             Limit    Margin                     Cable
              Level       Level                            Factor                   Factor    Height       Angle      Remark
  (MHz)                             (dBuV/m)    (dB)                    Loss (dB)
            (dBuV/m)     (dBuV)                            (dB/m)                    (dB)      (cm)       (Degree)
  0.147       80.48      101.11      104.26    -23.78      20.31          0.02      40.96      100           360      Average
  0.294       60.35      80.86       98.24     -37.89      20.27          0.02       40.8      100           360      Average
  0.441       53.77      74.15       94.72     -40.95      20.26          0.05      40.69      100           360      Average
  0.588       49.54      69.88       72.22     -22.68      20.25          0.08      40.67      100           360         QP
  0.735       48.77      69.11       70.28     -21.51      20.26           0.1       40.7      100           360         QP
  0.882       47.88      68.22       68.69     -20.81      20.27          0.12      40.73      100           360         QP
  1.029       44.62      64.96       67.36     -22.74      20.27          0.13      40.74      100           360         QP

Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.
5. Above limits have been translated by the formula




Report No.: RF180821C20-4                            Page No. 13 / 25                                Report Format Version: 6.1.1


 EUT Test Condition                                     Measurement Detail

 Input Power                120 Vac, 60 Hz              Frequency Range      30 MHz ~ 1000 MHz
 Environmental
                            25 deg. C, 65 % RH          Detector Function    Peak
 Conditions
Tested By                   Jisyong Wang

Horizontal




Vertical




Report No.: RF180821C20-4                    Page No. 14 / 25                  Report Format Version: 6.1.1


                               Antenna Polarity & Test Distance: Horizontal at 3 m
            Emission         Read                          Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level          Level                          Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)        (dBuV)                          (dB/m)       (dB)                   (cm)    (Degree)
  43.58       22.64         39.66        40       -17.36     13.59       0.5      31.11         152       111        Peak
  202.66       27.3          48.3        43.5     -16.2       9.48      1.24      31.72         165       231        Peak
  324.88      19.78         36.32        46       -26.22     13.54      1.77      31.85         185       265        Peak
  633.34      24.28         33.35        46       -21.72     20.01      3.04      32.12         111       185        Peak
  851.59      28.39         33.54        46       -17.61     22.89      3.84      31.88         111       231        Peak
  947.62       29.5         33.34        46       -16.5      23.78      4.22      31.84         165       285        Peak
                                    Antenna Polarity & Test Distance: Vertical at 3 m
            Emission         Read                          Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level          Level                          Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)        (dBuV)                          (dB/m)       (dB)                   (cm)    (Degree)
  204.6       21.29         42.17        43.5     -22.21      9.56      1.25      31.69         165       132        Peak
  378.23      18.65         33.77        46       -27.35     14.82        2       31.94         111       195        Peak
  580.96      23.05         33.18        46       -22.95     19.17      2.82      32.12         174       152        Peak
  705.12      25.78         33.32        46       -20.22     20.89      3.33      31.76         165       231        Peak
  795.33      27.97         33.57        46       -18.03     22.16      3.66      31.42         158       111        Peak
  902.03      28.89         33.34        46       -17.11     23.52      4.05      32.02         165       132        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
2. Margin value = Emission level – Limit value.
3. The other emission levels were very low against the limit.




Report No.: RF180821C20-4                            Page No. 15 / 25                             Report Format Version: 6.1.1


<Standby Mode>
EUT Test Condition                                           Measurement Detail

 Input Power                    120 Vac, 60 Hz               Frequency Range                 0.009 ~ 30 MHz
Environmental                                                                                Average
                                25 deg. C, 65 % RH           Detector Function
Conditions                                                                                   Quasi-Peak
Tested By                       Jisyong Wang


                                 Antenna Polarity & Test Distance: Open at 3 m
            Emission    Read                            Antenna                   Preamp   Antenna        Table
Frequency                           Limit    Margin                     Cable
              Level     Level                            Factor                   Factor    Height       Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                    Loss (dB)
            (dBuV/m)   (dBuV)                            (dB/m)                    (dB)      (cm)       (Degree)
  0.261      66.01      86.53      99.27     -33.26      20.28          0.02      40.82      100           360      Average
  0.399      65.01      85.42      95.58     -30.57      20.26          0.04      40.71      100           360      Average
  0.529      50.23      70.57      73.13       -22.9     20.25          0.07      40.66      100           360         QP
  0.669      61.21      81.55       71.1       -9.89     20.26          0.09      40.69      100           360         QP
  0.789      48.12      68.46      69.66     -21.54      20.26          0.11      40.71      100           360         QP
  0.911      52.01      72.35      68.41       -16.4     20.27          0.12      40.73      100           360         QP
                                 Antenna Polarity & Test Distance: Close at 3 m
            Emission    Read                            Antenna                   Preamp   Antenna        Table
Frequency                           Limit    Margin                     Cable
              Level     Level                            Factor                   Factor    Height       Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                    Loss (dB)
            (dBuV/m)   (dBuV)                            (dB/m)                    (dB)      (cm)       (Degree)
  0.278      63.01      83.53      98.72     -35.71      20.27          0.02      40.81      100            0       Average
  0.351      62.85      83.31       96.7     -33.85      20.26          0.03      40.75      100            0       Average
  0.501      50.75      71.09      73.61     -22.86      20.25          0.06      40.65      100            0          QP
  0.629      57.25      77.59      71.63     -14.38      20.26          0.08      40.68      100            0          QP
  0.771      45.98      66.33      69.86     -23.88      20.26           0.1      40.71      100            0          QP
  0.899      48.03      68.37      68.53       -20.5     20.27          0.12      40.73      100            0          QP
                            Antenna Polarity & Test Distance: Ground-parallel at 3 m
            Emission    Read                            Antenna                   Preamp   Antenna        Table
Frequency                           Limit    Margin                     Cable
              Level     Level                            Factor                   Factor    Height       Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                    Loss (dB)
            (dBuV/m)   (dBuV)                            (dB/m)                    (dB)      (cm)       (Degree)
  0.236      64.01      84.56      100.15    -36.14      20.28          0.02      40.85      100           360      Average
  0.371      65.25      85.68      96.22     -30.97      20.26          0.04      40.73      100           360      Average
  0.485      50.98      71.33      93.89     -42.91      20.25          0.06      40.66      100           360         QP
  0.621      58.65      78.99      71.74     -13.09      20.26          0.08      40.68      100           360         QP
  0.748      48.25      68.59      70.13     -21.88      20.26           0.1       40.7      100           360         QP
  0.889      50.36      70.7       68.63     -18.27      20.27          0.12      40.73      100           360         QP

Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.
5. Above limits have been translated by the formula




Report No.: RF180821C20-4                          Page No. 16 / 25                                Report Format Version: 6.1.1


 EUT Test Condition                                     Measurement Detail

 Input Power                120 Vac, 60 Hz              Frequency Range      30 MHz ~ 1000 MHz
 Environmental
                            25 deg. C, 65 % RH          Detector Function    Peak
 Conditions
Tested By                   Jisyong Wang

Horizontal




Vertical




Report No.: RF180821C20-4                    Page No. 17 / 25                  Report Format Version: 6.1.1


                               Antenna Polarity & Test Distance: Horizontal at 3 m
            Emission         Read                          Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level          Level                          Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)        (dBuV)                          (dB/m)       (dB)                   (cm)    (Degree)
  206.54      25.69         46.44        43.5     -17.81      9.65      1.26      31.66         152       213        Peak
  323.91       17.9         34.47        46       -28.1      13.52      1.77      31.86         111       231        Peak
  461.65      20.74         33.82        46       -25.26     16.56      2.33      31.97         165       285        Peak
  589.69      23.15         33.07        46       -22.85     19.37      2.85      32.14         195       251        Peak
  738.1        26.2         32.89        46       -19.8      21.35      3.46       31.5         111       165        Peak
  914.64      29.07          33.4        46       -16.93     23.59      4.11      32.03         102       251        Peak
                                    Antenna Polarity & Test Distance: Vertical at 3 m
            Emission         Read                          Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level          Level                          Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)        (dBuV)                          (dB/m)       (dB)                   (cm)    (Degree)
  33.88       30.84         48.83        40       -9.16      12.63      0.46      31.08         102       251        Peak
  202.66      20.42         41.42        43.5     -23.08      9.48      1.24      31.72         165       231        Peak
  416.06      19.36         33.59        46       -26.64     15.66      2.14      32.03         147       185        Peak
  620.73      23.85         33.17        46       -22.15     19.86      2.99      32.17         165       285        Peak
  852.56      28.28          33.4        46       -17.72      22.9      3.86      31.88         165       295        Peak
  965.08      30.16         33.89        54       -23.84     23.87       4.3       31.9         111       165        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
2. Margin value = Emission level – Limit value.
3. The other emission levels were very low against the limit.




Report No.: RF180821C20-4                            Page No. 18 / 25                             Report Format Version: 6.1.1


4.2      Conducted Emission Measurement
4.2.1      Limits of Conducted Emission Measurement

                                                              Conducted Limit (dBuV)
         Frequency (MHz)
                                               Quasi-Peak                                  Average
             0.15 - 0.5                           66 - 56                                  56 - 46
             0.50 - 5.0                             56                                        46
             5.0 - 30.0                             60                                        50
Note:
1. The lower limit shall apply at the transition frequencies.
2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.
3. All emanations from a class A/B digital device or system, including any network of conductors and
      apparatus connected thereto, shall not exceed the level of field strengths specified above.


4.2.2      Test Instruments

        Description &                                                         Date of              Due Date of
                                  Model No.              Serial No.
        Manufacturer                                                         Calibration           Calibration
Test Receiver
                                     ESCI                   100613         Nov. 23, 2017           Nov. 22, 2018
ROHDE & SCHWARZ
RF signal cable
                                    5D-FB            Cable-cond1-01        Sep. 05, 2018           Sep. 04, 2019
Woken
LISN/AMN
ROHDE & SCHWARZ                    ENV216                   101826         Feb. 26, 2018           Feb. 25, 2019
(EUT)
LISN/AMN
ROHDE & SCHWARZ                    ESH3-Z5                  100311         Aug. 19, 2018           Aug. 18, 2019
(Peripheral)
Software                       BV ADT_Cond_
                                                             NA                  NA                      NA
ADT                               V7.3.7.4

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 1.
      3. The VCCI Site Registration No. is C-2040.




Report No.: RF180821C20-4                        Page No. 19 / 25                          Report Format Version: 6.1.1


4.2.3   Test Procedures

a.   The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
     connected to the power mains through a line impedance stabilization network (LISN). Other support units
     were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50 uH of
     coupling impedance for the measuring instrument.
b.   Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c.   The frequency range from 150 kHz to 30 MHz was searched. Emission levels under (Limit – 20 dB) was
     not recorded.


NOTE: The resolution bandwidth and video bandwidth of test receiver is 9 kHz for quasi-peak detection (QP)
        and average detection (AV) at frequency 0.15 MHz - 30 MHz.




Report No.: RF180821C20-4                     Page No. 20 / 25                       Report Format Version: 6.1.1


4.2.4   Deviation from Test Standard

No deviation.


4.2.5   Test Setup

                                   Vertical Ground
                                   Reference Plane                                Test Receiver


                                   EUT                                         o o o o
                      40cm          U                                        1 5 a s o




                                                        80cm
                      LISN
                               L                L1                           L
                                                        \            N
                                                                    Ho
                                                                                              T
                                                                      rizontal G
                                                                                 round
                                                                    Refere       Plane
                                                                           nce

                        Note: 1.Support units were connected to second LISN.




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.2.6   EUT Operating Conditions

Same as 4.1.6.




Report No.: RF180821C20—4                       Page No. 21 / 25                           Report Format Version: 6.1.1


4.2.7   Test Results
                                                                 Detector Function &               .
Frequency Range             150kHz ~ 30MHz                       Resolu}ion                  S:;'S;;;Ze(%/go:lzr/lz
                                                                 Bandwidth                                   "
Input Power                 120Vac, 60Hz                         Eg‘r’]';‘ii?o’:]‘:”‘a'      25°C, 65%RH
Tested by                   Jisyong Wang                         Test Date                   2018/9/18


                                                   Phase Of Power : Line (L)
        Frequency      |Correction|         Reading Value      Emission Level                  Limit                  Margin
 No                         Factor               (dBuV)             (dBuV)                     (dBuV)                  (dB)
           (MHz)             (dB)            Q.P.      AV.      Q.P.      AV.              Q.P.      AV.          Q.P.       AV.
  1       0.15000            9.67           30.53     16.62    40.20     26.29            66.00     56.00        —25.80    —29.71
  2       0.18075            9.67           28.42     1541     38.09     25.08            64.45     54.45        —26.36    —29.37
  3       0.39635            9.66           23.74     10.05    33.40     19.71            57.93     47.93        —24.53    —28.22
  4       0.48626            9.66           82.23     15.07    41.89     24.73            56.23     46.23        —14.34    —21.50
  5       2.06981            9.68           24.76     8.59     34.44     18.27            56.00     46.00        —21.56    —27.73
  6       7.84097            9.81           30.94     1543     40.75     25.24            60.00     50.00        —19.25    —24.76
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value
                             =aaaeaeaaufig




                                                                                                 soke
                                    0
                                    a




                                                                                                  mane




Report No.: RF180821C20—4                              Page No. 22 / 25                                  Report Format Version: 6.1.1


                                                              Detector Function & Quasi—Peak (QP) /
Frequency Range             150kHz ~ 30MHz                    g{giglwultgl)fl            Average (AV), 9KHz


Input Power                 120Vac, 60Hz                      Eg‘r’]';‘ii?o”r:sma'      25°C, 65%RH
Tested by                   Jisyong Wang                      Test Date                 2018/9/18


                                              Phase Of Power : Neutral (N)
        Frequency      |Correction|   Reading Value         Emission Level                Limit                   Margin
 No                         Factor         (dBuyV)              (dBuV)                    (dBuyV)                  (dB)
           (MHz)             (dB)      Q.P.       AV.        Q.P      AV.             Q.P.       AV.          Q.P.       AV.
  1       0.17283            9.68     12.93      1.33       22.61    11.01           64.82      54.82        —42.21    —43.81
  2       0.47453            9.67     15.90      0.92       25.57    10.59           56.43      46.43        —30.86    —35.84
  3      0.81861            9.66      15.58       2.86      25.24        12.52       56.00        46.00      —30.76      —33.48
  4      7.86834            9.81      21.15       240       30.96        12.21       60.00        50.00      —29.04      —37.79
  5      12.87314           9.91      22.87       4.70      8278         14.61       60.00        50.00      —27.22      —35.39
  6      17.17023           9.97      21.74       2.34      31.71        12.31       60.00        50.00      —28.29      —37.69
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value
                             $#
                              B
                              #
                              s
                              g
                              8
                              g
                              s
                              8
                              B0
                              8
                              59




                                                                                             :l'llm
                              &




                                                                                              rane




Report No.: RF180821C20—4                           Page No. 23 / 25                                  Report Format Version: 6.1.1


5    Pictures of Test Arrangements

Please refer to the attached file (Test Setup Photo).




Report No.: RF180821C20-4                      Page No. 24 / 25   Report Format Version: 6.1.1


Appendix – Information on the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                       Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF180821C20-4                      Page No. 25 / 25                  Report Format Version: 6.1.1



Document Created: 2019-05-01 01:35:31
Document Modified: 2019-05-01 01:35:31

© 2024 FCC.report