PCE conducted RF emissions report

FCC ID: V65C5155

Test Report

Download: PDF
FCCID_1724170

          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




                                 RF Emissions Test Report

                                       FCC Part 22 and 24

                                                     For

                                  Kyocera Corporation
                            c/o Kyocera Communication Inc.




                          Product:          Tri-Band CDMA Mobile Phone
                             Model:                    C5155




© 2012 Comptest Services LLC                         Page 1 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


               COMPTEST                                                                            Applicant:
                                                                                                    FCC ID:
                                                                                                                     Kyocera
                                                                                                                     V65C5155
                                Services LLC                                                       Report #:         CT-C5155-22_24-0412-R0

                                                          TABLE OF CONTENTS


1     SUMMARY OF TESTING ......................................................................................................... 4
2     EQUIPMENT UNDER TEST INFORMATION........................................................................... 4
3     TEST FACILITIES..................................................................................................................... 5
4     TEST SETUP ............................................................................................................................ 5
    4.1 Test Configuration .............................................................................................................. 6
5     tty compliance ........................................................................................................................... 7
6     Conducted RF OUTPUT POWER............................................................................................. 7
    6.1 Test Configuration .............................................................................................................. 7
    6.2 Test Results........................................................................................................................ 7
7     RADIATED RF OUTPUT POWER............................................................................................ 8
    7.1 Test Configuration .............................................................................................................. 8
8     PEAK-AVERAGE RATIO .......................................................................................................... 9
    8.1 Test Configuration .............................................................................................................. 9
    8.2 Test Result ......................................................................................................................... 9
9     OCCUPIED BANDWIDTH ...................................................................................................... 11
    9.1 Test Configuration ............................................................................................................ 11
    9.2 Test Result ....................................................................................................................... 11
10 Spurious Emissions At Antenna Terminals ............................................................................. 16
  10.1 Test Configuration ............................................................................................................ 16
  10.2 Test Result ....................................................................................................................... 16
11 Transmitter Radiated Spurious Emission................................................................................ 23
12 Receiver Spurious Emissions ................................................................................................. 23
  12.1 Receiver Spurious Emissions........................................................................................... 23
13 Transmitter RF Carrier Frequency Stability............................................................................. 24
  13.1 Test Configuration ............................................................................................................ 24
  13.2 Test Result ....................................................................................................................... 25
14 Exposure of Humans to RF Fields (SAR) ............................................................................... 27
  14.1 Test Configuration and Result .......................................................................................... 27
15 TEST EQUIPMENT................................................................................................................. 27




© 2012 Comptest Services LLC                         Page 2 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0



                                             ATTESTATION

  The tested device complies with the requirements in respect of all parameters subject to the
  test.
  The test results and statements relate only to the items tested.
  The test equipment used was suitable for the tests performed and within manufacturer’s
  published specifications and operating parameters.
  The test methods were consistent with the methods described in the relevant standards.
                           Product: Tri-Band CDMA Cellular Phone with Bluetooth

                           Model #: C5155

                             FCC ID: V65C5155

    Tested in accordance with: FCC Part 22 & 24

              Test performed by: CompTest Services LLC

              Test Requested by: Kyocera Corporation
                                 c/o Kyocera Communication Inc
                                 8611 Balboa Avenue
                                 San Diego, CA 92121 United States
                      Date of Test: April 10, 2012




    Responsible Engineer                                            Reviewed and approved by:

    Benjamin Nguyen


    Benjamin Nguyen                                                 Tammy To
    Test Engineer                                                   Quality Manager




© 2012 Comptest Services LLC                         Page 3 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


           COMPTEST                                                     Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0



1         SUMMARY OF TESTING

 Section #     Rule Part                                 Test Description                             Verdict
      6        FCC § 2.1046                              Conducted Power                               Pass
      7        FCC § 22.913, 24.232                      Radiated Power                                Pass
      8        FCC § 24.232(d)                           Peak-to-Average Ratio                         Pass
      9        FCC § 2.1049, 22.917 (b)(d), 24.238       Occupied Bandwidth                            Pass
                                                         Spurious Emissions at Antenna
     10        FCC § 2.1051, 22.917(e)(f), 24.238                                                      Pass
                                                         Terminals
                                                         Transmitter Radiated Spurious
     11        FCC § 2.1053, 22.91, 24.238                                                             Pass
                                                         Emissions
     12        FCC § 15.109                              Receiver Spurious Emissions                   Pass
                                                         Transmitter RF Carrier Frequency              Pass
     13        FCC § 2.1055, 22.355, 24.235
                                                         Stability
     14        FCC § 2.1093                              Exposure of Humans to RF Fields               Pass



2         EQUIPMENT UNDER TEST INFORMATION

            EUT Serial Number: 268435457816726141
                            Type: [ ] Prototype, [X] Pre-Production, [ ] Production
           Equipment Category: Portable
    RF Exposure Environment: General Population / Uncontrolled
                        Antenna: Internal Antenna                               Detachable Antenna: No
                 External Input: Audio/Digital Data
                        Quantity: Quantity production is planned
     Multiple Access Scheme: CDMA
          Emission Designators: 1M25F9W

                FCC Rule Parts: §22H                                     §24E
                           Mode: CDMA 1X & EvDo Rev0                     CDMA 1x & EvDo Rev0
                           Band: BC-0                                    BC-1
           TX Frequency (MHz): 824 – 849                                 1850 - 1910



© 2012 Comptest Services LLC                         Page 4 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0



3      TEST FACILITIES

The test sites and measurement facilities used to collect data are located at 8611 Balboa
Ave., San Diego, CA 92121, USA



4      TEST SETUP

All CDMA measurements were conducted with a base station simulator to establish a CDMA link with
the equipment under test (EUT). To investigate the response of the EUT the main antenna RF output
port of the EUT was connected to the input of the spectrum analyzer with a RF cable. The amplitude
of the spectrum analyzer is corrected for the cable insertion loss and any other applicable losses. A
fully charged battery was used as a power supply voltage, except for the Transmitter RF Carrier
Frequency Stability test a dummy battery connected to a power supply was used.




                             Base Station                                 Spectrum
                              Simulator                                   Analyzer




                                                Directional
                                                 Coupler




© 2012 Comptest Services LLC                         Page 5 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0



4.1     Test Configuration
 To justify on the selection of applicable configurations, the EUT was pre-tested under all
 Radio Configuration and Service Option operation modes to determine the worst-case
 scenario.

 The following configuration was determined and reported as worst-case for all
 measurements:
                           Radio Configuration: RC1
                              Service Options: SO55
                                    Data Rate: Full Rate


   CONFIGURATION                                     CONDUCTED POWER (dBm)
                                       CDMA 800 BC-0                                 CDMA 1900
       Peak Power
                             Ch1013        Ch 384         Ch 777         Ch 25        Ch 600        Ch 1175
                              Peak          Peak           Peak          Peak          Peak           Peak
 SO2, RC1 Full Rate           29.71         30.20          29.89         27.61         29.56          29.87
 SO2, RC3 Full Rate           29.33         29.67          29.30         27.27         29.10          29.56
 SO55, RC1 Full Rate          29.87         30.24          29.84         29.33         30.38          29.84
 SO55, RC3 Full Rate          29.32         29.64          29.31         29.01         29.70          29.51
 TDSO SO32, RC3
                              29.40         29.83          29.29         27.37         29.10          29.56
 (+SCH) Full Rate
 TDSO SO32, RC3
                              29.30         29.56          29.44         27.32         29.05          29.45
 (+F-SCH) Full Rate



   CONFIGURATION                                     CONDUCTED POWER (dBm)
                                       CDMA 800 BC-0                                 CDMA 1900
      Average Power         Ch 1013        Ch 384         Ch 777         Ch 25        Ch 600        Ch 1175
                               Avg           Avg           Avg            Avg           Avg           Avg
 SO2, RC1 Full Rate           24.67         24.67          24.53         24.46         24.49          24.62
 SO2, RC3 Full Rate           24.65         24.59          24.52         24.44         24.48          24.61
 SO55, RC1 Full Rate          24.70         24.81          24.53         24.46         24.49          24.63
 SO55, RC3 Full Rate          24.65         24.60          24.53         24.46         24.50          24.63
 TDSO SO32, RC3
                              24.68         24.58          24.55         24.42         24.51          24.60
 (+SCH) Full Rate
 TDSO SO32, RC3
                              24.65         24.72          24.47         24.39         24.49          24.60
 (+F-SCH) Full Rate




© 2012 Comptest Services LLC                         Page 6 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0


5       TTY COMPLIANCE
    FCC: § 255 of the Telecom Act

 The EUT has been designed for TTY Compliance with Cellular Compatibility Standard.




6       CONDUCTED RF OUTPUT POWER

 6.1     Test Configuration
     FCC: § 2.1046
        IC: RSS132 §4.4; RSS133 §6.4

 The EUT was connected to a Universal Power Meter through a RF cable. The cable loss
 was taken into account for accurate power measurement. The EUT was set at low, mid, high
 channels and each frequency band to investigate the conducted power.




 6.2     Test Results
                             Frequency                                           Conducted Power
         Mode                                          Channel
                               (MHz)                                                 (dBm)
                                  824                    1013                            24.65
       CDMA 800                 836.52                    384                            24.60
                                848.31                    777                            24.53
                                1851.25                    25                            24.46
       CDMA 1900                 1880                     600                            24.50
                                1908.75                  1175                            24.63




© 2012 Comptest Services LLC                         Page 7 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0



7      RADIATED RF OUTPUT POWER

 7.1     Test Configuration
     FCC: § 22.913, § 24.232
        IC: RSS132 §4.4; RSS133 §6.4

 The test was performed in Compliance Certification Service using substitution method. See
 separated radiated emission report for details.

 The test report is attached in a separate attachment.




© 2012 Comptest Services LLC                         Page 8 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


             COMPTEST                                                   Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0



8       PEAK-AVERAGE RATIO

 8.1     Test Configuration
      FCC: § 24.232(d)
        IC: RSS133 (6.4)

    The RF output of the EUT was connected to the input of the spectrum analyzer (S.A.) with
    sufficient attenuation. The spectrum analyzer Complementary Cumulative Distribution
    Function (CCDF) function is utilized to determine the largest deviation between average
    and peak power of the EUT.

    For Digital: Modulate with full rate and all up power control bit.

     S.A. Setting                         RBW                         VBW
     Power Stat CCDF                      5MHz                        auto


 Limits: <13 dB




 8.2     Test Result

    Figure                                                            Mode                    Result
                               Description
       8-1                   CCDF @ Ch600                         CDMA 1900                     Pass




© 2012 Comptest Services LLC                         Page 9 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




                                         Figure 8-1 CCDF @ CH 600




© 2012 Comptest Services LLC                        Page 10 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


             COMPTEST                                                   Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0



9       OCCUPIED BANDWIDTH

 9.1     Test Configuration
      FCC: § 2.1049, § 22.917(b)(d), § 24.238, § 27.53(g)(1)
        IC: RSS132 §4.5; RSS133 §6.5

    The RF output of the EUT was connected to the input of the spectrum analyzer (S.A.) with
    sufficient attenuation. The spectrum with no modulation was recorded.

    For Digital: Modulate with full rate all up power control bit.

     S.A. Setting                         RBW                         VBW
     Bandwidth Measurement                30KHz                       300kHz
     Band Edge Measurement                30KHz                       100KHz


 Limits: Bandwidth: N/A
         Bandedge: -13dBm




 9.2     Test Result

    Figure                                                            Mode                    Result
                               Description
       9-1                   CDMA @ Ch384                                                       Pass
       9-2           Lower Band Edge @ Ch 1013                     CDMA 800                     Pass
       9-3            Upper Band Edge @ Ch 777                                                  Pass
       9-4                  CDMA @ CH600                                                        Pass
       9-5            Lower Band Edge @ CH 25                     CDMA 1900                     Pass
       9-6           Upper Band Edge @ CH 1175                                                  Pass




© 2012 Comptest Services LLC                        Page 11 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




                                      Figure 8-1 CDMA 800 @ CH 384




© 2012 Comptest Services LLC                        Page 12 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




                          Figure 8-2 CDMA 800 Lower Band Edge @ CH 1013




                           Figure 8-3 CDMA 800 Lower Band Edge @ CH 777




© 2012 Comptest Services LLC                        Page 13 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




                                     Figure 8-4 CDMA 1900 @ CH 600




© 2012 Comptest Services LLC                        Page 14 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




                           Figure 8-5 CDMA 1900 Lower Band Edge @ CH 25




                          Figure 8-6 CDMA 1900 Upper Band Edge @ CH 1175




© 2012 Comptest Services LLC                        Page 15 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


           COMPTEST                                                     Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                          Services LLC                                  Report #:    CT-C5155-22_24-0412-R0



10      SPURIOUS EMISSIONS AT ANTENNA TERMINALS

 10.1 Test Configuration
     FCC: § 2.1051, § 22.917(e)(f), § 24.238
        IC: RSS132 §4.5; RSS133 §6.5

 Measurement Procedures:

   Out of Band: The RF output of the EUT was connected to the input of the spectrum
   analyzer with sufficient attenuation. The modulating signal was applied accordingly. The
   frequency spectrum was investigated from the lowest frequency signal generated up to at
   least the tenth harmonic of the fundamental.

     S.A. Setting                         RBW                        VBW
     Spurious Emissions
     Measurement
                                          1MHz                       1MHz


 Limits: -13dBm




 10.2 Test Result
  Figure       Channel                          Plot Description                                Result
     9-1          1013                                                                            Pass
                                 CDMA 800 Conducted spurious emissions
     9-2            384                    9kHz to 10GHz                                          Pass
     9-3            777                                                                           Pass
     9-4            25                                                                            Pass
                                 CDMA 1900 Conducted spurious emissions
     9-5            600                     9kHz to 20GHz                                         Pass
     9-6          1175                                                                            Pass




© 2012 Comptest Services LLC                        Page 16 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




               Figure 9-1a CDMA 800 – Conducted Spurious Emission (CH 1013)




               Figure 9-1b CDMA 800 – Conducted Spurious Emission (CH 1013)




© 2012 Comptest Services LLC                        Page 17 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




                Figure 9-2a CDMA 800 – Conducted Spurious Emission (CH 384)




               Figure 9-2b CDMA 800 – Conducted Spurious Emission (CH 384)




© 2012 Comptest Services LLC                        Page 18 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




                Figure 9-3a CDMA 800 – Conducted Spurious Emission (CH 777)




               Figure 9-3b CDMA 800 – Conducted Spurious Emission (CH 777)




© 2012 Comptest Services LLC                        Page 19 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




                Figure 9-4a CDMA 1900 - Conducted Spurious Emission (CH 25)




                Figure 9-4b CDMA 1900 - Conducted Spurious Emission (CH 25)



© 2012 Comptest Services LLC                        Page 20 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




               Figure 9-5a CDMA 1900 - Conducted Spurious Emission (CH 600)




               Figure 9-5b CDMA 1900 - Conducted Spurious Emission (CH 600)




© 2012 Comptest Services LLC                        Page 21 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0




              Figure 9-6a CDMA 1900 - Conducted Spurious Emission (CH 1175)




              Figure 9-6b CDMA 1900 - Conducted Spurious Emission (CH 1175)




© 2012 Comptest Services LLC                        Page 22 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0


11     TRANSMITTER RADIATED SPURIOUS EMISSION




    FCC: § 2.1053, § 22.91, § 24.238, §27.53(g)
       IC: RSS132 §4.5; RSS133 §6.5
The radiated spurious emission test was performed at Compliance Certification Service. The
test report is attached in a separate attachment.



12     RECEIVER SPURIOUS EMISSIONS

12.1 Receiver Spurious Emissions
   FCC: § 15.109
      IC: RSS-GEN
The receiver radiated spurious emission test was performed at Compliance Certification
Service. The test report is attached in a separate attachment.




© 2012 Comptest Services LLC                        Page 23 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


           COMPTEST                                                     Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0


13     TRANSMITTER RF CARRIER FREQUENCY STABILITY


 13.1 Test Configuration
     FCC: § 2.1055, § 22.355, § 24.235, § 27.54
       IC: RSS132 §4.3; RSS133 §6.3
 The EUT was placed in an environmental chamber. The RF output of the EUT was
 connected to Agilent 8960 Series 10 E5515C. A power supplier was connected as primary
 voltage supply. Only the mid channel of each frequency band was investigated.



 Limits:

                Tx Frequency                  Channel                          Limit
                 836.52 MHz                      384                +/- 2.5 ppm (+/- 2091 Hz)
                  1880 MHz                       600                +/- 2.5 ppm (+/-4700 Hz)




© 2012 Comptest Services LLC                        Page 24 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                    COMPTEST                                                                Applicant:
                                                                                             FCC ID:
                                                                                                         Kyocera
                                                                                                         V65C5155
                                           Services LLC                                     Report #:    CT-C5155-22_24-0412-R0


     13.2 Test Result
                                                                       CDMA 800
                                                   Deviation of Carrier (Hz)                Specification (Hz)
              ( o ture
                  )                             3.3V
                 ra


                                                                           4.2V                                           Result
                C
               pe




                                              (Battery       3.7V                       Lower limit      Upper limit
             m




                                                                          (115%)
           Te




                                             endpoint)
                                -30                            -0.71                      -2091             2091
                                -20                            -1.36                      -2091             2091
                                -10                            -0.57                      -2091             2091
                                 0                             -0.64                      -2091             2091
                                 10                            -0.34                      -2091             2091
                                                                                                                          Pass
                                 20            0.36             0.58        1.12          -2091             2091
                                 30                             1.45                      -2091             2091
                                 40                             1.38                      -2091             2091
                                 50                             1.46                      -2091             2091
                                 60                             1.35                      -2091             2091



                                          CDMA 800 MHz Transmitter RF Carrier Stability
                                                Over Temperature and Voltage

                                3000
         Frequency Error (Hz)




                                2000
                                                                                                                   3.3V
                                1000
                                                                                                                   3.7V
                                      0                                                                            4.2V
                                                                                                                   Upper Limit
                                -1000
                                                                                                                   Lower Limit
                                -2000

                                -3000
                                          -30 -20 -10      0      10   20    30    40     50    60
                                                        Temperature (Celsius)




© 2012 Comptest Services LLC                        Page 25 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


               COMPTEST                                                                Applicant:
                                                                                        FCC ID:
                                                                                                    Kyocera
                                                                                                    V65C5155
                                         Services LLC                                  Report #:    CT-C5155-22_24-0412-R0



                                                                  CDMA 1900
            ( o ture                             Deviation of Carrier (Hz)             Specification (Hz)
                )                             3.3V
               ra

                                                                         4.2V                                       Result
              C
             pe



                                            (Battery       3.7V                   Lower limit       Upper limit
           m




                                                                        (115%)
         Te




                                           endpoint)
                                -30                        0.48                       -4700            4700
                                -20                        0.9                        -4700            4700
                                -10                        0.87                       -4700            4700
                                 0                         0.55                       -4700            4700
                                 10                       -0.92                       -4700            4700
                                                                                                                    Pass
                                 20          -1.25        -1.51         -1.60         -4700            4700
                                 30                       -2.47                       -4700            4700
                                 40                       -2.12                       -4700            4700
                                 50                       -1.12                       -4700            4700
                                 60                       -1.48                       -4700            4700



                                        CDMA1900 MHz Transmitter RF Carrier Stability
                                              Over Temperature and Voltage

                                 6000
                                 5000
         Frequency Error (Hz)




                                 4000
                                 3000                                                                         3.3V
                                 2000                                                                         3.7V
                                 1000
                                    0                                                                         4.2V
                                -1000
                                -2000                                                                         Upper Limit
                                -3000                                                                         Lower Limit
                                -4000
                                -5000
                                -6000
                                         -30 -20 -10      0    10    20    30    40   50      60
                                                      Temperature (Celsius)




© 2012 Comptest Services LLC                        Page 26 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5155
                       Services LLC                                     Report #:    CT-C5155-22_24-0412-R0



14     EXPOSURE OF HUMANS TO RF FIELDS (SAR)

  14.1 Test Configuration and Result
     FCC: § 2.1093
       IC: RSS102
  The SAR test report is attached in a separate attachment.




15     TEST EQUIPMENT

The test equipment utilized to perform the tests documented in this report has been calibrated in
accordance with the manufacturer’s recommendations and is traceable to recognized national standards.

  Description                       Manufacturer          Model No.           Serial No.           Cal Due
                                                                                                    Date
  Power Meter                      Giga-tronics          8541C                 1831306            09/08/12
  Spectrum Analyzer                Agilent               E4440A              MY44303130           12/14/12
  Wireless
                          Agilent                        8960                GB44052789           08/17/12
  Communications Test Set
                                                         ZH2-033-033-
  Temperature Chamber              Test Equity           H/AC
                                                                              ZZ9622421           06/24/12




© 2012 Comptest Services LLC                        Page 27 of 27                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.



Document Created: 2012-05-02 20:24:26
Document Modified: 2012-05-02 20:24:26

© 2024 FCC.report