                               Manual




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


                                                        Yale Real Living™
                                      Key Free Push Button Deadbolt B1L with       WAVE
                                           Installation and Programming Instructions
                                                                                          ®
                                                                                                   Preparing Door                     1     Installing Latch & Strike Plate
                                                                                                                                                           2-3/8" position
                                                                                                                                                                                                     2         Installing Keypad Escutcheon                                   3      Installing Interior Mounting Plate



                                                                                                                                                                        UP




                                                                                                                                      x4

                                                                                                                                                            2-3/4" position
                                                                                                                                                                                                     Inside of Door                        Outside of Door

                                                                                                                                                                                           O
                                                                                                                                                                                          optional
                                                                                                                                                                             UP




                                                                                                                                                                                  Pull                                                                                        x2
                                                                                                                                                          Press



                                                                                                                                                  Bolt must be in retracted
                                                                                                                                                  (unlocked) position. Note
                                                                                                                                              !    horizontal orientation of
                                                                                                                                                         mechanism.




     x3
 #8-32 x 5/16’’
Machine screws
                  x4
           #7 wood & #8-32
           machine x 20mm
                                                                                                                                                                                                                          !
          Combination screws                                                                                                                                                                                  Bolt must be in retracted
                               x2                                                                                                                                                                             (unlocked) position. Note
                          M6x47mm                                                                                                                                                                              horizontal orientation of
                       Long through bolt                                                                                                                                                                             mechanism.
                               P/N AYRD-110-INST-FUL Rev A




    4             Attaching the Cable Assembly                                                5      Installing Interior Escutcheon        Testing Operation                                              Handing the Lock                                                    6      Installing Cover

                                                                                                                                                                                                                                              Press . Press . Enter new
                                                                                                                                                                                                                                              Master PIN code (4-8 digits).
                                                                                                                                                                                                                                                 Press to complete.

                                                                                              x3




                                                                                                                                                                                                                                                                               Congratulations, you've installed the Yale Real Living™
                                                                                                                                                                                                                                                                               Key Free Push Button Deadbolt B1Lwith       WAVE ! Turn
                                                                                                                                                                                                                                                                                                                              ®



                                                                                                                                                                                                        After entering the Master PIN                                          sheet over for Programming Instructions to customize
                                                                                                                                                                                                       code, press any key to complete
                                                                                                                                                                                                                                                                                                   your product.
                                                                                                                                                                                     !                             handing.


                                                                                                                                                                     Bolt must be in retracted
                                                                                                                                                                    (unlocked) position before
                                                                                                                                                                        installing batteries.


             Programming Instructions
             Low Battery Warning- Flashes RED                                                             1          Creating Master PIN Code
                                                                                                                           Press
                                                                                                                                                                                                               2                Creating User PIN Codes
                                                                                                                                                                                                                                Master PIN code must be created first.
                                                                                                                                                                                                                                *Max User Codes = 100
                                                                                                                                                                                                                                                                                                                                      3            Unlocking Door with PIN Code                                                   Resetting Lock to Factory Default
                                                                                                                                                                                                                                                                                                                                                                                                                                  When lock is reset to factory defaults all
                                                                                                                                                                                                                                                                                                                                                                                                                                  user codes (including the Master PIN code*)
 Lock-out Mode- Keypad Flashes                                                                                                                                                                                                                                                                                                                                                                                                    are deleted and all programming features
                                                                                                                                                                                                                                                                                                                                                         Enter PIN
                                                                                                                                                                                                            Enter Master PIN code                                             Press                                                                                                                                               are reset to original default settings (see
                                                                                                                                                                                                                                                                                                                                                         Press
                                                                                                                                                                                                            Press                                                             Press                                                                                                                                               "Factory Default Settings").
                                                                                                                                                                                                                                                                                                                                                         "Unlock"
                                                                                                                                                                                                                                                                                                                                                                                                                                  1. Remove the battery cover.
                                                                                                                                                                                                                                                                                                                                                                                                                                  2. Remove the batteries.
                                                                                                                                                                                                                                                                                                                                                                                                                                  3. While pressing the reset button (minimum
                                                                                                                                                                                                                                                                                                                                                                                                                                     of 3 seconds) reinstall batteries. Release
                                                                                                                                                                                                                                                                                                                                                                                                                                     reset button.
                                                                                                                                                                                                                                                                                                                                                                                                                                  4. Replace battery cover.

                                                                                                                                                                                                                                                                                                                                                                                                                                  Upon reset, Master Code creation is the
                                                                                                                                                                                                                                                                                                                                                                                                                                  only option available and must be
                                                                                                                                                                                                                                                                                                                                                                                                                                  performed prior to any other programming
                                                                                                                                                                                                                                                                                                                                                                                                                                  of the lock.
                                                                                                                                                                                                                                                                                                                                                                                                                                  NOTE: After setting the Master Code, press
                                                                                                                           Press                                                                                                                                                                                                                                                                                                  any key to complete handing of the lock.
                                                                                                                                                                                                           Press                                                              Enter User number to be created
                                                                                                                           Press
                                                                                                                                                                                                                                                                              (1-100)*.                                             Code Chart              Duplicate if necessary
                                                                                                                                                                                                           Press
                                                                                                                                                                                                                                                                              Press                                                           PIN Code Management (With Network Module - Up to 100 Users)                         Enrolling Lock In                                           ®
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  Network
                                                                                                                                                                                                                                                                                                                                          User Type                User Name                User #       PIN Code                 Your network controller first needs to be in
                                                                                                                                                                                                                                                                                                                                                                                                                                  enrollment or exclusion mode for the lock to
                                                                                                                                                                                                                                                                                                                                          Master
                                                                                                                                                                                                                                                                                                                                                                                                                                  be enrolled or removed from network.
                                                                                                                                                                                                                                                                                                                                          User ___
                                                                                                                                                                                                                                                                                                                                                                                                                                  Once you put the controller in the
                                                                                                                                                                                                                                                                                                                                          User ___                                                                                enrollment or exclusion mode, the lock can
                                                                                                                                                                                                                                                                                                                                          User ___                                                                                be enrolled or removed in the Z-Wave®
                                                                                                                                                                                                                                                                                                                                                                                                                                  network two ways - through the keypad
                                                                                                                                                                                                                                                                                                                                          User ___                                                                                using the #7 key (see Programming
                                                                                                                                                                                                                                                                                                                                          User ___                                                                                Through Menu Mode) or by pressing the
                                                                                                                                                                                                                                                                                                                                                                                                                                  button.
                                                                                                                                                                                                                                                                                                                                          User ___
                                                                                                                            Enter 4-8                                                                                                                                                                                                                                                                                             To enroll lock using the button option:
                                                                                                                            digit Master                                                                   Enter 4-8 digit PIN code                    0:20                                                                               User ___
                                                                                                                                                                                                                                                                                                                                                                                                                                  1. Remove the battery cover.
                                                                                                                            PIN Code.                                                                      Press                                         STOP                                                                             User ___                                                                                2. Press button and hold until unit beeps
                                                                                                                                                                                                                                                                                                                                                                                                                                     two (2) times.
                                                                                                                           Press                                                                                                                                                                                                          User ___                                                                                3. Release button and network joining
                                                                                                                                                                                                                                                                                                                                          User ___                                                                                   automatically begins.
                                                                                                                                                                                                                                                                                                                                                                                                                                  4. Replace battery cover.
                                                                                                                                                                                                                                                                                                                                          User ___
                                                                 Failsafe 9 volt
                                                                                                                                                                                                                                                                                                                                                                                                                                  To remove lock using the button option:
                                                                 Battery Connection                                                                                                                                                                                                                                                       User ___
                                                                                                                                                                                                                                                                                                                                                                                                                                  1. Remove the battery cover.
                                                                                                                                                                                                                                                                                                                                          User ___                                                                                2. Press button and hold until unit beeps
           Master PIN Code must be created before any further programming.                                                                                                                                                                                                                                                                                                                                                           five (5) times.
           Max User Codes = 100                                                                                                                                                                                                                                                                                                           User ___
                                                                                                                                                                                                                                                                                                                                                                                                                                  3. Release button and network removal
  !        Warning: Changes or modifications to this device, not expressly approved by
           Yale Security Inc. could void the user's authority to operate the equipment.
                                                                                                                                                                                                                                                                                                                                          User ___
                                                                                                                                                                                                                                                                                                                                          User ___
                                                                                                                                                                                                                                                                                                                                                                                                                                     automatically begins.
                                                                                                                                                                                                                                                                                                                                                                                                                                  4. Replace battery cover.



Definitions                                                                                       Feature Programming Through Menu Mode                                                                  Programming Troubleshooting                                                                                                FCC:
                                                                                                                                                                                                                                                                                                                                   FCC ID: U4A-YRIZW1US (Z-Wave®)
                                                                                                                                                                                                                    Symptom                                             Suggested Action
All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it              Using Master PIN code*                                                                                                                           • Press each keypad button for response when pressed.
                                                                                                                                                                                                                                                                                                                                   Model(s): YRD110-ZW-US
                                                                                                                                                                                                                                                                                                                                   This equipment has been tested and found to comply with the limits for a Class B digital
restricts all user (except Master) PIN code access. When attempting to enter a code while                                                                                                                                                         • Check batteries are installed and oriented correctly (polarity)
                                                                                                                                                                                                         Lock does not respond –                                                                                                   device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
the unit is in Lockout, the Status Indicator flashes RED (8 times); the keypad flashes as well.    1. Enter the 4-8 digit Master PIN code followed by the    key.                                          door is open and                           in the battery case.
                                                                                                                                                                                                         accessible.                              • Check batteries are in good condition; replace batteries*                      reasonable protection against harmful interference in a residential installation. This
                                                                                                 2. Enter digit corresponding to the function to be performed followed by the                    key.                                               if discharged.                                                                 equipment generates, uses, and can radiate radio frequency energy and, if not installed and
Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone
play-back for use in quiet areas. Audio mode is enabled or disabled through feature                   Note: If the lock is connected to a network controller, it is recommended that it is                                                        • Check to see if cable is fully connected and not pinched.                      used in accordance with the instructions, may cause harmful interference to radio
programming by the Master code.                                                                       programmed through the centralized user interface (PC or hand-held device) to                      Lock does not respond –                                                                                                   communications. However, there is no guarantee that interference will not occur in a
                                                                                                      ensure communication between the lock and the controller unit.                                                                              • Batteries may be completely discharged.
                                                                                                                                                                                                         door is locked and                       • Apply 9V battery to terminals below the keypad for backup                      particular installation. If this equipment does cause harmful Interference to radio or
Automatic Re-lock Time: After a successful unlock, the unit will automatically re-lock after a   *The Master PIN code must be registered prior to any other programming                                  inaccessible.                              power option.                                                                  television reception, which can be determined by turning the equipment off and on, the user
default of thirty (30) seconds. Re-lock time is adjustable** from 10-180 seconds.                 of the lock.                                                                                                                                                                                                                     is encouraged to try to correct the interference by one or more of the following measures:
                                                                                                                                                                                                         Unit chimes to indicate                  • Check to see if there is another locking device on the door.
                                                                                                                                                                                                                                                                                                                                       Reorient or relocate the receiving antenna.
                                                                                                      1        2                                                                                         code acceptance, but the                 • Check the door gaps for any foreign objects between door
Low Battery: When battery power is low, the Status Indicator flashes RED. If battery power                                                                                                                door will not open.                        and frame.                                                                         Increase the separation between the equipment and receiver.
                                                                                                  M                                                   M                User Number (UN)                                                           • Check that the cable is firmly connected to the PC board.                           Connect the equipment into an outlet on a circuit different from that to which the
is completely lost, use the 9Volt battery override. To use the 9V battery override apply 9V                         Master PIN Code Setting
                                                                                                                                                                       1~100: with network module        Unit operates to allow                                                                                                         receiver is connected.
battery, in either direction, to terminals below the keypad for backup power option. Wake up                                                                                          U                                                           • Check to see if Auto Re-lock Mode is enabled.
                                                                                                                   User PIN Code Registration             Register                                       access, but will not                                                                                                          Consult the dealer or an experienced radio/TV technician for help.
the lock and enter your pin code to unlock the door.                                                                                                                                                     automatically re-lock.                   • If low battery indicator is lit (see below), change batteries*.

                                                                                                                                                           Delete                                                                                 • PIN codes must consist of 4 to 8 digits to register.                           Industry Canada:
Master PIN Code: The Master PIN code is used for programming and for feature settings. It                                                                                                                                                         • The same PIN code cannot be used for multiple users.
must be created prior to programming the lock. The Master code will also operate                                                                                                                         PIN codes will not register.                                                                                              Canadian ID: 6982A-YRIZW1US (Z-Wave®)
                                                                                                                                                                                                                                                  • Registration/management of PIN codes is set by the
(unlock/lock) the lock.                                                                                            Advanced Lock Settings                 Automatic Re-lock                Enable                                                                                                                                  Model(s): YRD110-ZW-US
                                                                                                                                                                                                                                                    authority of the Master Code.
                                                                                                                                                                                                                                                  • Contact the Master user.                                                       This Class B digital apparatus meets all requirements of the Canadian Interference Causing
                                                                                                                                                                                           Disable
Network Setting: This setting is available thru the main Menu (7) and allows the lock to                                                                                                                                                          • User codes must be entered within 5 seconds or the                             Equipment Regulations. Operation is subject to the following two conditions: (1) this device
connect with a network controller. It is also available through the wireless button on the                                                                One Touch Locking                Enable                                                   process will have to be restarted.                                             may not cause harmful interference, and (2) this device must accept any interference
                                                                                                                       Default settings                                                                                                           • Check mark       or gear   cannot be used as part of the                       received, including interference that may cause undesired operation.
interior escutcheon .                                                                                                                                                                      Disable
                                                                                                                       in bold.                                                                                                                     PIN code.                                                                      Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence
                                                                                                                                                          Handing the Lock                 Performs      Upon entering a PIN code                                                                                                  canadienne causant des règlements d'équipement. L'opération est sujette aux deux
One Touch Locking: When the latch is retracted, activating the keypad will extend the latch                                                                                                automatic
(during Automatic Re-lock duration or when Automatic Re-lock is disabled).                                                                                                                               and pressing the (*) key, the            • All Code Lockout Mode is enabled.                                              conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce
                                                                                                                                                                                           handing of
                                                                                                                    Audio Mode              Enable                                         the lock.     lock gives a series of beeps,            • Only the Master can enable/disable All Code Lockout Mode.                      dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui
                                                                                                                                                                                                         flashes red & blue LEDs 7                 • Contact the Master user.                                                       peut causer l'opération peu désirée.
Shutdown Time: The unit will shutdown for a default of sixty (60) seconds and not allow                                                                   For quiet areas, select Disable (3)            times, and does not unlock.
                                                                                                                                            Disable       in Audio Mode.
operation after the wrong code entry limit has been met. When the unit is in Shutdown, the                                                                                                               Upon entering a PIN code                 • Check to see if the lock is set to All Code Lockout Mode.
Status Indicator flashes RED; the keypad flashes as well.                                                                 N/A                                                                                                                                                                                                        Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may
                                                                                                                                                                                                         and pressing the (*) key,                • Setting/managing All Code Lockout Mode is done through
                                                                                                                                                                                                         there are different tones.                 Master Code only. Contact the Master user.                                     only operate using an antenna of a type and maximum (or lesser) gain approved for the
                                                                                                                     All Code Lockout Mode                 Enable                                        The unit operates, but it                                                                                                 transmitter by Industry Canada. To reduce potential radio interference to other users, the
Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.                                                                                                                                                       • Enable Audio Mode.
                                                                                                                                                                                                         makes no sound.                                                                                                           antenna type and its gain should be so chosen that the equivalent isotropically radiated
                                                                                                                                                           Disable
User PIN Code: The User code operates the lock. Maximum number of user codes is 100.                                                                                                                                                              • This is the Low Battery indicator alerting that it is time to                  power (e.i.r.p.) is not more than that necessary for successful communication.                          Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com
                                                                                                                                                                                                         The unit displays inter-
                                                                                                                         Network Setting                   Join the network                                                                         replace the batteries. Replace all four (4) batteries* with                    En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec
                                                                                                                                                                                                         mittent RED flashes.                                                                                                                                                                                                         Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
                                                                                                                                                                                                                                                    new AA Alkaline batteries.                                                     une antenne d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par
Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering a                                                                                                                   Upon entering a PIN code
                                                                                                                                                           Exit the network                                                                                                                                                        Industrie Canada. Pour réduire le risque d'interférence aux autres utilisateurs, le type
valid PIN code, the unit will shut down and not allow operation. Wrong code entry limit is                                                                                                               and pressing the (*) key,                • The digits entered were incorrect or incomplete. Re-enter
adjustable from three (3) to ten (10) times**. Default is 5.                                       Factory Default Settings                                                                              the unit responds with a
                                                                                                                                                                                                         series of beeps and the
                                                                                                                                                                                                                                                    the correct code followed by the check mark (*) key.
                                                                                                                                                                                                                                                                                                                                   d'antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée
                                                                                                                                                                                                                                                                                                                                   équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie.
                                                                                                                                                                                                                                                                                                                                                                                                                                      Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
                                                                                                                                                                                                                                                                                                                                                                                                                                    Yale Real Living™ is a trademark of Yale Security Inc., an ASSA ABLOY Group company.
                                                                                                                                                                                                         keypad flashes three times.                                                                                                                                                                                                             Copyright © 2014, Yale Security Inc., an ASSA ABLOY Group company.
                                                                                                                 Settings                          Factory Default                                      * When batteries are replaced, Network locks have a real time clock that will be set through the User Interface (UI); it
**Adjustable through a Z-Wave® controller.                                                                                                                                                              is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).        Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS            All rights reserved. Reproduction in whole or in part without the express written permission
                                                                                                             Master PIN Code                    Registration required*                                                                                                                                                                                                                                                                                            of Yale Security Inc. is prohibited.
                                                                                                                                                                                                                                                                                                                                   standard(s). Operation is subject to the following two conditions: 1) this device may not
                                                                                                            Automatic Re-lock                          Disabled
                                                                                                                                                                                                                                                                                                                                   cause interference, and 2) this device must accept any interference, including interference
                                                                                                            One Touch Locking                          Enabled
                                                                                                                                                                                                                                                                                                                                   that may cause undesired operation of the device.
                                                                                                                  Audio                                Enabled                                                                                                                                                                     Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son
                                                                                                          Automatic Re-lock Time                    **30 Seconds                                                                                                                                                                   fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer
                                                                                                                                                                                                                                                                                                                                                                                                                                             YALE, with its unique global reach and range of products, is the world's favorite lock
                                                                                                                                                                                                                                                                                                                                                                                                                                              – the preferred solution for securing your home, family and personal belongings.
                                                                                                          Wrong Code Entry Limit                      **5 Times                                                                                                                                                                    des interférences, et 2) cet appareil doit accepter toute interférence, y compris les
                                                                                                              Shutdown Time                         **60 Seconds                                                                                                                                                                   interférences qui peuvent causer un mauvais fonctionnement du dispositif.
                                                                                                   *The Master PIN code must be registered prior to any other programming of the lock.                                                                                                                                                                                                                                                                   ASSA ABLOY is the global leader in door opening solutions,
                                                                                                   **Adjustable through a Z-Wave® controller.                                                                                                                                                                                                                                                                                                     dedicated to satisfying end-user needs for security, safety and convenience.