User Manual - FM404 IN100 Bored Instr

FCC ID: U4A-SCYMCA1

Users Manual

Download: PDF
FCCID_3061108

Cylindrical Lockset
IN100 WiFi
Installation Instructions
                                                                                                          FM404 07/16
                                                                      Attention Installer

     Please read these instructions carefully to prevent missing important steps.
     Please Note: Improper installations may result in damage to the lock and void the factory warranty.
     Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
                        Misalignment can cause premature wear and a lessening of security.




                                  For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473)
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.


IN100 Cylindrical Lock


                                                                    Table of Contents

                  1) Warning.................................................................................2
                  2) General Description..............................................................3
                  3) Specifications / Features.....................................................3
                  4) Product Illustration..............................................................4
                  5) Installation Instructions.......................................................6
                  6) Operational Check............................................................. 16
                  7) LED Indications..................................................................17
                                                                         1) Warning
                                      Warning: Changes or modifications to this unit not expressly approved by the party
                                      responsible for compliance could void the user’s authority to operate the equipment.

                     This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
                     cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
                     undesired operation.
                     Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
                     Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
                     This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc-
                     tions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in
                     a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
                     turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
                     • Reorient or relocate the receiving antenna
                     • Increase the separation between the equipment and receiver
                     • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
                     • Consult the dealer or an experienced technician for help
                     The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class
                     B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the
                     following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received,
                     including interference that may cause undesired operation.
                     Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements
                     d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce
                     dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

       !             To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
                     To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling
                     electronic components:

                         !
                     • Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges,
                       latches, and mounting plates especially when mounting electronic components such as readers and controllers onto
                       the door.
                     • Leave components (reader and controller) protected in their respective anti-static bags until ready for installation
                     • Do not touch pins, leads or solder connections on the circuit boards


Copyright © 2016 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
                                                                                                    2


IN100 Cylindrical Lock


                                                                      2) General Description
          The Corbin Russwin® IN100 lock with Aperio™ Technology makes it easy and cost-effective to bring access
          control to more doors. It uses local wireless communication between the lock and an Aperio hub to connect
          to an access control system, eliminating the greatest cost and inconvenience of traditional access control –
          the wiring at the door.
          The IN100 utilizes HID® 125 kHz prox or 13.56 MHz iCLASS® smart card technology, and all technology
          features are supported by the physical security of Corbin Russwin ANSI/BHMA Grade 1 hardware.
          This product is operated by six (6) “AA” alkaline batteries. Corbin Russwin locks are designed with quality
          components to provide high security, performance and durability.

                                                                3) Specifications / Features
         Hardware Specifications
            • Latch – Stainless steel, ½” (13mm) throw                             • Outside lever controlled by reader or key
              Optional: ¾” (19mm) throw deadlocking fire                             retracts latch
              latch for pairs of doors                                             • Inside Lever produces REX (request to
            • Deadlocking latch prevents manipulation when                           exit) signal
              door closed                                                          • Complete monitoring of door - DPS
            • Door Thickness – Standard 1-3/4” (44mm) to                             (External Door Position Switch supplied)
              2” (50mm)                                                            • May be used for both indoor and
              Optional 2” (50mm) to 2-1/4” (57mm)                                    exterior applications.
            • UL fire listed
                                             A weather-protective gasket is required for exterior applications.


         Electronic Specifications
            •     Input Power: DC 9V, 1.5A (6 AA alkaline batteries)               •    Uses low-rate wireless personal area networks
            •     Optional hard-power 12VDC to 24VDC                                    (IEEE 802.14.4)
            •     HID® multiCLASS SE® technology offers support                    •    Multiple time zone and holiday access scheduling
                  for the following credentials:                                   •    First-in unlock or automatic unlock configuration,
                        • High Frequency (13.56 MHz):                                   based on specified time schedule
                            • HID iCLASS®                                          •    Uses AES 128-bit wireless encryption*
                            • HID iCLASS SE® (SIO-enabled)                         •    Privacy button
                            • HID iCLASS® Seos™
                            • HID MIFARE® SE
                            • HID DESfire® EV1 SE
                            • MIFARE Classic
                            • DESfire EV1
                        • Low Frequency (125 kHz):                                     *For specific security information, please contact
                                                                                       your local ASSA ABLOY Door Security Solutions
                            • HID Prox®                                                sales consultant or call 800-810-WIRE.
                        • NFC-enabled Mobile Phones



                   !      To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.



Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.            3


IN100 Cylindrical Lock


                                                                      4) Product Illustration

                                               1                                             2
                                                                                                                        3
                                                                                                                                       4
                                                                                                                                                            5




                           Reader Module




  ITEM            PART NUMBER/ORDER STRING                     DESCRIPTION                                                                          COLOR/TRIM              QTY
    1               IN-100-EM01CL33134-IP-B                    HID iCLASS , HID iCLASS SE (SIO-enabled), HID iCLASS Seos™, HID MIFARE
                                                                            ®               ®                           ®                       ®
                                                                                                                                                    Black                    1
                                                               SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
                    IN-100-EM01CL33134-IP-W                    HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®            White                    1
                                                               SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
              IN-100-EM01CL33134-IP-MB-[finish]*               HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®            Black with metal trim    1
                                                               SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
              IN-100-EM01CL33134-IP-MW-[finish]*               HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®            White with metal trim    1
                                                               SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
                    IN-100-EM01CL33134-IPS-B                   All credentials supported by the IP option plus MIFARE Classic and DESfire EV1       Black                    1
                   IN-100-EM01CL33134-IPS-W                    All credentials supported by the IP option plus MIFARE Classic and DESfire EV1       White                    1
              IN-100-EM01CL33134-IPS-MB-[finish]*              All credentials supported by the IP option plus MIFARE Classic and DESfire EV1       Black with metal trim    1
             IN-100-EM01CL33134-IPS-MW-[finish]*               All credentials supported by the IP option plus MIFARE Classic and DESfire EV1       White with metal trim    1
    2                          820F558                         Inside Mounting Kit (mounting plate & hardware)                                                               1
    3                          820F549                         IN100 Controller                                                                                              1
    4                             N/A                          AA battery                                                                                                    6
    5                          820F489                         Inside Escutcheon                                                                    Black                    1
                               820F499                         Inside Escutcheon                                                                    White
                            820F525 FIN*                       Inside Escutcheon                                                                    Black with metal trim
                            820F535 FIN*                       Inside Escutcheon                                                                    White with metal trim
    6                           FM356                          Field prep template (not shown)                                                                               1
    7                          T31203                          Door manufacturers template (not shown)                                                                       1
    --                          FM404                          Instructions (this manual)                                                                                    1

            * Specify finish




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.                    4


IN100 Cylindrical Lock


                                                         4) Product Illustration (Continued)


     Tools Required:
           • Phillips Screw Driver #2, #3
           • Flat Blade Screw Driver (Standard size)
           • 1/8” Security Allen Wrench (supplied)                                                                            4




                                                                                                     2



                                                 3




                                                                                1




                         1*                785F628                CL33134 Cylindrical lock with fixed core cylinder       1
                                           785F638                CL33134 Cylindrical lock with removable core cylinder
                          2                785F488                Inside Spring Cassette - IN100 REX (1-3/4” - 2” Door)   1
                                           785F498                Inside Spring Cassette - IN100 REX (2-1/4” Door)
                          3                783F208                Outside Spring Cassette                                 1
                          4                820F609                DPS (Door Position Switch) Kit                          1


                              *The IN100 CL33134 cylindrical lock supports Escape Return functionality.


                                          For parts not listed, refer to CL3300 Parts and Service Manual.




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.                   5


IN100 Cylindrical Lock



                                                                  5) Installation Instructions

      1.             Verify Hand and Bevel of door

                      Illustrations shown are as viewed from the outside or secure side of opening.




                                Left Hand                           Left Hand                      Right Hand      Right Hand
                               Hinges Left.                       Reverse Bevel                   Hinges Right.   Reverse Bevel
                               Open Inward.                        Hinges Left.                   Open Inward.    Hinges Right.
                                  “LH”                            Open Outward                        “RH”        Open Outward
                                                                     “LHRB”                                         “RHRB”
                                                                                      Fig. 1

      2.             Door Preparation
                    Prep door according to supplied door marker (FM356). For door manufacturer templates
                          visit www.corbinrusswin.com and reference template # T31203.




                                                                                      Wood Door                                   Inside Face
                    Outside Face                                                       shown                                        of Door
                      of Door


  Raceway for Optional
       Remote Power                                                                                                                Raceway for Optional
                                                                                                                                   Remote Power



                                                                                                                                  Through-bolt
                                                                                                                                      Hole
                 Through-bolt Hole


                                                                                      External DPS
                                                                                          Hole                                        Raceway for
                    Raceway for                                                                                                        Lockbody
                     Lockbody                                                                                                           Harness
                      Harness


                                                                                        Cylindrical
                Through-bolt Hole                                                       Pocket and                                  Through-bolt
                                                                                        Pre-drilled                                     Hole
                                                                                        Tap Holes



                                                                                      Lever Handle
                                                                                          Hole



                                                                                         Fig. 2

Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.                                                                       Cable Hole
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.                 6


IN100 Cylindrical Lock



                                                    5) Installation Instructions (Continued)

      3.             Install Door Position Switch (DPS)
                    a. Insert DPS into the raceway on the latch edge of the door.
                    b. Push wires through raceway toward lock prep.
                    c. Push DPS firmly into place by hand.
                       Note: DO NOT TAP SWITCH WITH ANY TOOL.
                    d. Install magnet into door frame. Push firmly into place by hand.
                       See instruction A7983A.


                                 CAUTION: if DPS is not installed or is installed
                                 improperly, door status monitoring features will
                                 not function.




                                                                                                        Fig. 3



      4.             Install Latch Bolt
                     Install latch bolt with beveled bolt facing the strike
                             using two #8 x 3/4” combination screws (Fig. 4):




                                                                                                        Fig. 4




      5.             Install Strike Plate
                     Install Strike Plate using two #12 x 1” combination
                     screws (Fig. 5):                                   Optional Strike Box




                                                                                               Fig. 5
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.     7


IN100 Cylindrical Lock


                                                   5) Installation Instructions (Continued)

      6.             Install Lock Body
                    a. Feed lock body and wire through 2-1/8” diameter hole from outside of door (Fig. 6a).
                       Engage latch with lock body. Latch ears must slide into housing as shown (Fig. 6b).
                    b. Connect 4-pin connector from lock body to 4-pin on
                       cassette (Fig. 6c).


                                           Outside Face of Door




                                                                                                   6   Fig. 6b




                                                                      Fig. 6a




                      c. Temporarily install top throughbolt to hold chassis in door (Fig. 6c).

                          Important: Door must remain open during installation.
                          Use door stop.
                                                                                                       Inside Face of Door

                      d. Connect REX wire from I/S cassette to
                         lockbody harness.




                                                                                                          Spring Cassette




                                                                                         Fig. 6c




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.           8


IN100 Cylindrical Lock


                                                    5) Installation Instructions (Continued)

      7.             Install Inside Spring Cassette Lock
                      a. Feed harness wires and ground wire up through raceway (Fig. 7a).
                      b. Remove screw from previous step.
                      c. Slide on cassette and secure with (2) screws (Fig. 7b).




                                                                                Remove Screw




                                                                                           Fig. 7a   Spring Cassette




                                                              Fig. 7b




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.       9


IN100 Cylindrical Lock


                                                   5) Installation Instructions (Continued)

      8.             Installation and Removal of Lever and Standard Cylinder




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.     10


IN100 Cylindrical Lock


                                                    5) Installation Instructions (Continued)

      9.             Install Outside (Reader) Escutcheon and Inside Mounting Plate
                       a. Orient the reader so the LED lens is at the top.
                       b. Feed reader harness through door (from outside to inside).
                       c. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes.
                              Hold the reader flush against door while ensuring proper alignment.




                                                  Outside Face of Door




                                LED




                         Reader Assembly
                           with Harness




                                                                         Fig. 9a




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.              11


IN100 Cylindrical Lock


                                                   5) Installation Instructions (Continued)
    d. Feed the reader harness and DPS connectors through the inside mounting assembly
      (and gasket if required*). See Figure 9b.
        IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 9b, c) - it will damage wires and
        the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 9c).
    e. Tuck excess cable into wire hole on inside of door.
    f. Begin to secure the mounting assembly by partially tightening the (2) through-bolts on the
       inside of the door while ensuring proper alignment as you secure the reader (Fig. 9b).


                                                                 Inside of Door
                                                                                          NOTE: Cable lengths exaggerated for illustrative purposes.

                                                                            Gasket*

                                                                                       Mounting Plate


                                                                                           Through -
                                                                                              bolt


                                                                                            DPS
                                                                                               Reader
                                                                                               Harness
                                                                                                         Lock body
                                                                                                          Harness




                                                                                                  Through -
                                                                                      Ground         bolt
                                                                                       Lug




                                                                                                                             Fig. 9c

                                                                 Fig. 9b




    g. Secure ground lug with #6-32 machine screw (Fig. 9c).

                *Gasket is required for outdoor installations.
                If installing with gasket; separate gasket from mounting plate to feed cables/connectors through holes
                as indicated (Fig. 9b).
                Once cables/connectors are fed through, reattach gasket to mounting plate.

Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.                 12


IN100 Cylindrical Lock


                                                    5) Installation Instructions (Continued)

   10.               Installation of Connectors
                                                                                                              9-24VDC
                                                                                               DPS (4-pin)
      CAUTION - Do not touch or allow debris to enter connector contacts.                                     Power*
                                                                                                       A
       Secure the following connectors to their respective terminals (Fig. 10D):
       A. Secure the 4-pin DPS connector.
       B. Secure the 10-pin lock body assembly connector.
                                                                                   Ground                            B
          *NOTE: Optional 2-pin external 9-24VDC power connector.
                                                                                    Lug

      IMPORTANT: Do not run wires through bottom hole in plate - it will
                 damage wires and the controller connector.
                 Route wires around flange, do not route wires through
                 the flange hole (Fig. 10B, D).
                                                                                                 Fig. 10D      Lock
                                                                                                               Body
       C. When all connections have been made, tuck excess cable                                               (10-pin)
          into wire hole on inside of door.




          Secure Mounting Plate
           D. Secure the mounting assembly while ensuring proper
              alignment of outside reader and tighten the (2) through-bolts
              on the inside of the door to secure the reader (Fig. 10E).

                                                                                                                     Fully
           E. Secure the 24-pin card reader connector (Fig. 10F).                                                    tighten



                                              Reader         D
                                              (24-pin)


                                                                                                   Fig. 10E




               Board-to-Board
                 Connector

                                                          Fig. 10F




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.     13


IN100 Cylindrical Lock


                                                    5) Installation Instructions (Continued)

      11.               Installation of Inside Component Assembly
                        CAUTION: To avoid possible damage to board-to-board connectors,
                                 care should be taken when securing controller to mounting
                                 plate. If there is resistance when securing, detach controller
                                 to determine cause before re-attaching controller.

                       a. Insert top tabs of controller into slots on mounting plate (Fig. 11).
                       b. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller
                          toward door until tab on bottom snaps securely into place on mounting plate.




                                                                                     Inside Face of
                                                                                          Door




                                                                           Fig. 11




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.     14


IN100 Cylindrical Lock


                                                    5) Installation Instructions (Continued)

      12.               Battery Installation
                 1. Place (6) “AA” alkaline batteries in the compartment, being
                    careful to align polarity properly (Fig. 12).
                 2. After batteries are installed, there is a slight delay; then red and
                    green flash, audible “beep” and lock motor will cycle.




                                                                                           Fig. 12




      13.               Inside Cover Installation
                                                                                                                     Inside
                                                                                                                     Cover
                       a. Assemble cover by hooking top edge on inside
                          mounting plate.
                       b. Carefully press bottom of cover toward door without
                          pinching or damaging wires.
                       c. Secure cover utilizing security allen wrench (provided).




                                                                                                               Security Allen
                                                                                                                  Screw




                                                                                                     Fig. 13



Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.     15


IN100 Cylindrical Lock


                                                                      6) Operational Check

            When lock is fully installed, perform the following steps:

              a. Insert key into cylinder and rotate (Fig. 14a).
              b. There should be no friction against lock case, wire harness or
                 any other obstructions.
              c. Check that the key retracts the latch.
              d. The key should rotate freely.
              e. Try the inside lever; ensure it retracts latch.
              f. Present a valid credential* (Fig. 14b) to unlock outside lever; turn
                  lever handle to ensure latch retracts.




                                                                                                                 Fig. 14a




                                                                                 Note: The credential should approach the inscription
                                                                                       on the reader as indicated (Fig. 13b) to ensure
                                                                                       that the credential is read properly.
                                                                                       Do not wave credential.
                                   Fig. 14b




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.           16


IN100 Cylindrical Lock


                                                                          7) LED Indications
            The communication hub has a single LED. It supports an optical scheme of red, green and yellow.
            The indication scheme is described by the figures below:

                            Figure 1.
                                                                      Communication Hub LED indications

                Communication hub normal
                 operation LED indication

                                                                                                 2 sec.


                                                                        Online                                             Green

                                                              Aperio® lock                                                 Green + one
                                                                    offline                                                red flash
                                                                                             Green + two red flashes
                                                                 EAC offline

                                                       Aperio® lock and                                                    Green + three
                                                             EAC offline                                                   red flashes

                                                                 UHF                                                       Yellow + off,
                                                        communication                                                      fast flash

                                                    Some special LED indication schemes* are
                                                    used during lock maintenance actions:
                                                                                                    2 sec.
                            Figure 2.

            Communication hub maintenance                  Pairing active                                                       Yellow + green
                   LED indication


                                                                                 Ethernet LED indication
                                                         The LED on the AH40 communication hub* indicates both the status of
                                                         the Ethernet link level and ethernet communication:

                                                                                                 2 sec.
                            Figure 3.

                 AH40 Communication hub                         Ethernet
                  Ethernet LED indication                link connected                                                    Green

                                                             Ethernet                                                      Green +
                                                        communication                                                      off fast flash

                                                  *For more information, refer to Aperio Online Quick Installation Guide
                                                  (Document No: ST-001322-PF Date: 2015-12-23)


Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.                   17


IN100 Cylindrical Lock


           Lock LED indications
           The lock has three LEDs. They support an optical scheme of red, yellow and green.
           The indication scheme is described by the figures below:
               Figure 4. Lock normal operation LED
                             indication
                                                                      EAC response   Enter PIN
                                          Card + PIN access               time
                                                                                                 One yellow flash after card, two
                                               (configurable)
                                                                                                 flashes before PIN (.125 second)
                                                  Card access
                                                 (configurable)                                  One yellow flash (.25 second)


                                         Access granted,                                         One green flash
                                     EAC offline or online                                       (1 sec.)

                                             Access denied,                                      One red flash
                                                EAC online                                       (1 sec.)

                                 Force closed in remote                                          Five yellow flashes and
                                      open/office mode                                           one red flash (.25 second)

                                   Busy blink, com hub                                           Continuous yellow flashes
                                   busy with other locks                                         (.25 seconds every second)

                                             Access denied,                                      Three red flashes
                                                EAC offline                                      (.5 second each)

                                    Lock mechanism is                                            Continuous red flashes
                                blocked when closing 1)                                          (.125 seconds every 1 sec.)

                                           Error in lock,                                        Ten red flashes (.125 sec. each)
                                   maintenance required                                          (Repeated every 10 sec. if lock can’t close)

                                                                                                 Ten red flashes (.125 sec. each)
                                                       Tamper
                                                                                                 repeated every 10 sec.

                                           Time to replace                                       Continuous yellow flashes
                                               the battery                                       (.25 seconds every 5 sec.)

                                       Battery reached end                                       Continuous red flashes (.25
                                       of life, lock disabled                                    seconds every 5 sec.)

                                  V3 USB cable detection                                         Five yellow flashes
                                         action occurred                                         (.25 second each)


                                              1) When the lock mechanism is blocked (lock jammed) the lever must be turned to
                                                 release the lock mechanism.


                                         Some special LED indication schemes are used during lock maintenance actions:
                  Figure 5. Lock hub normal
                   operation LED indication                    Enter configuration                               Five yellow flashes
                                                                            mode                                 (.125 second each)




Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.              18


IN100 Cylindrical Lock



                  Lock Self-Test LED indication
                     After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using
                     a series of red and green LED flashes as described by the figures below.

                      LED indication after power up/replacement of the battery
                             8.3.1       Battery not fully charged
                                       Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at the
                                       right voltage or a backward battery has been installed; battery not fully charged; energy counter
                                       not reset or no Power on self-test done.
                                               Error in lock,                                         Ten red flashes (.125 sec. each)
                                       maintenance required                                           (Repeated every 10 sec. if lock can’t close)


                             8.3.2       Test pass
                                       1 red (1s) + 1 green (1s), Power on self-test passed, see table below.


                     Figure 6. Lock POST LED             POST Successful                             One red, one green flash
                            indication                                                               (1 second)




                             8.3.3       Test fail
                                     1 red (1s) + 3 blinks (.5 sec, green or red), at least one test failed (red), see table below.
                          If a fatal error is detected the lock will enter an Error state and continuously indicating fatal error and will
                          not read cards nor unlock.



                                                                           1 sec        0.5 sec      0.5 sec      0.5 sec

                                                  FATAL ERROR


                                                CABLE ERROR


                                          MECHANICAL ERROR



                                                    FATAL ERROR            Tests core functionality - MCUs, memory and internal
                                                                           communication, etc.

                                                   CABLE ERROR             Tests communication between the different
                                                                           parts in the system, i.e. different boards
                                                                           connected with a wire.

                                             MECHANICAL ERROR Test related to moving parts of the lock.


Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.           19


Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
           All rights reserved. Reproduction in whole or in part without the
          express written permission of Corbin Russwin, Inc. is prohibited.



Document Created: 2016-06-28 15:08:50
Document Modified: 2016-06-28 15:08:50

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC