Test Report

FCC ID: TV7SXTG-2HND

Test Report

Download: PDF
FCCID_1773036

NVLAP Lab Code 200087-0



                             SUBMITTAL
                            APPLICATION
                               REPORT
                           FOR
                  GRANT OF CERTIFICATION
                                                  FOR


               Model: RBSXTG-2HnD
                  2412-2462 MHz
        Broadband Digital Transmission System
             FCC ID: TV7SXTG-2HND
                                                  FOR


                              MIKROTIKLS SIA
                                        Pernavas 46
                                    Riga, Latvia LV-1009

                               Test Report Number: 120716

Authorized Signatory:
                            Scot D. Rogers




Rogers Labs, Inc.                 Mikrotikls SIA
4405 W. 259th Terrace             Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053               Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214         Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                        File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 1 of 30


NVLAP Lab Code 200087-0


                            ROGERS LABS, INC.
                                         th
                            4405 West 259 Terrace
                            Louisburg, KS 66053
                            Phone / Fax (913) 837-3214




                    Engineering Test Report
                                For
                Grant of Certification Application
                                                  FOR
                       CFR 47, PART 15C - Intentional Radiators
                              CFR 47 Paragraph 15.247
                         License Exempt Intentional Radiator
                                                   For


                               MIKROTIKLS SIA
                                             Pernavas 46
                                         Riga, Latvia LV-1009

                                Broadband Digital Transmission System
                                       Model: RBSXTG-2HnD
                                  Frequency Range 2412-2462 MHz
                                     FCC ID#: TV7SXTG-2HND

Test Date:      July 16, 2012

Certifying Engineer:
                        Scot D. Rogers
                        Rogers Labs, Inc.
                        4405 West 259th Terrace
                        Louisburg, KS 66053
                        Telephone/Facsimile: (913) 837-3214

This report shall not be reproduced except in full, without the written approval of the laboratory.
This report must not be used by the client to claim product endorsement by NVLAP, NIST, or
any agency of the U.S. Government.


Rogers Labs, Inc.                 Mikrotikls SIA
4405 W. 259th Terrace             Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053               Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214         Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                        File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 2 of 30


NVLAP Lab Code 200087-0

Table Of Contents


TABLE OF CONTENTS.................................................................................................. 3

REVISIONS..................................................................................................................... 4

FORWARD ..................................................................................................................... 5

OPINION / INTERPRETATION OF RESULTS ............................................................... 5

ENVIRONMENTAL CONDITIONS.................................................................................. 5

EQUIPMENT TESTED .................................................................................................... 5

APPLICATION FOR CERTIFICATION ........................................................................... 6

APPLICABLE STANDARDS & TEST PROCEDURES .................................................. 7

EQUIPMENT FUNCTION AND CONFIGURATION........................................................ 7

     Equipment Configuration....................................................................................................................................8

TEST SITE LOCATIONS ................................................................................................ 8

UNITS OF MEASUREMENTS ........................................................................................ 8

TEST PROCEDURES ..................................................................................................... 9

     AC Line Conducted Emission Test Procedure ..................................................................................................9

     Radiated Emission Test Procedure .....................................................................................................................9

LIST OF TEST EQUIPMENT ........................................................................................ 10

INTENTIONAL RADIATORS ........................................................................................ 11

     Antenna Requirements ...................................................................................................................................... 11

     Restricted Bands of Operation .......................................................................................................................... 11

       General Radiated Emissions in Restricted Bands Data (General) ..................................................................... 12
       Harmonic Radiated Emissions in Restricted Bands Data .................................................................................. 12

     Summary of Results for Radiated Emissions in Restricted Bands ................................................................ 13


Rogers Labs, Inc.                                Mikrotikls SIA
4405 W. 259th Terrace                            Model: RBSXTG-2HnD                                                          SN: 399501DD0C31
Louisburg, KS 66053                              Test #: 120716                                                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214                        Test to: CFR47 (15.247)                                                     Date: July 31, 2012
Revision 1                                       File: Mikrotikls RBSXTG2HnD TstRpt 120716                                   Page 3 of 30


NVLAP Lab Code 200087-0

     AC Line Conducted Emissions Procedure ....................................................................................................... 13

       Figure One AC Line Conducted Emissions Line 1 ........................................................................................... 14
       Figure Two AC Line Conducted Emissions Line 2 ........................................................................................... 14
       AC Line Conducted Emissions Data (Highest Emissions) ................................................................................ 15

     Summary of Results for AC Line Conducted Emissions ................................................................................ 15

     General Radiated Emissions Procedure ........................................................................................................... 16

       General Radiated Emissions from EUT Data (Highest Emissions) ................................................................... 17

     Summary of Results for General Radiated Emissions .................................................................................... 17

     Operation in the Band 2400 – 2483.5 MHz ...................................................................................................... 18

       Figure Three Plot of Transmitter Emissions (Across Operational Band, 5 MHz Mode) ................................... 19
       Figure Four Plot of Transmitter Emissions (Across Operational Band, 10 MHz Mode) .................................. 19
       Figure Five Plot of Transmitter Emissions (Across Operational Band, 20 MHz Mode) ................................... 20
       Figure Six Plot of Transmitter Emissions (Across Operational Band, 40 MHz Mode) ..................................... 20
       Figure Seven Plot of Low Band Edge ............................................................................................................... 21
       Figure Eight Plot of High Band Edge ................................................................................................................ 21

     Transmitter Emissions Data .............................................................................................................................. 22

       Calculated Transmitter Antenna Port Power ..................................................................................................... 22
       Transmitter Radiated Emission.......................................................................................................................... 23
       Summary of Results for Transmitter Radiated Emissions of Intentional Radiator ............................................ 24

STATEMENT OF MODIFICATIONS AND DEVIATIONS ............................................. 24

ANNEX .......................................................................................................................... 25

     Annex A Measurement Uncertainty Calculations ........................................................................................... 26

     Annex B Rogers Labs Test Equipment List ..................................................................................................... 27

     Annex C Rogers Qualifications ......................................................................................................................... 28

     Annex D FCC Site Registration Letter ............................................................................................................. 29

     Annex E Industry Canada Site Registration Letter ........................................................................................ 30

 Revisions
Revision 1, Original Report Issued


Rogers Labs, Inc.                               Mikrotikls SIA
4405 W. 259th Terrace                           Model: RBSXTG-2HnD                                                         SN: 399501DD0C31
Louisburg, KS 66053                             Test #: 120716                                                             FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214                       Test to: CFR47 (15.247)                                                    Date: July 31, 2012
Revision 1                                      File: Mikrotikls RBSXTG2HnD TstRpt 120716                                  Page 4 of 30


NVLAP Lab Code 200087-0


Forward

The following information is submitted for consideration in obtaining Grant of Certification for
License Exempt Digital Transmission System Intentional Radiator operating under CFR 47
Paragraph 15.247.

        Name of Applicant:
                         Mikrotikls SIA
                         Pernavas 46
                         Riga, Latvia LV-1009
        Model: RBSXTG-2HnD

        FCC I.D.:    TV7SXTG-2HND                 FRN: 0014 43 1100
        Frequency Range: 2412-2462 MHz (5, 10, 20 MHz channel operation), 2422-2452 MHz (40
                         MHz channel operation)
        Operating Power: 1-Watt output power, 30 dBm


Opinion / Interpretation of Results
                       Tests Performed                         Margin (dB)        Results
 Emissions as per CFR 47 paragraphs 2 and 15.205                    -1.0         Complies
 Emissions as per CFR 47 paragraphs 2 and 15.207                   -11.0         Complies
 Emissions as per CFR 47 paragraphs 2 and 15.209                    -2.6         Complies
 Harmonic Emissions per CFR 47 15.247                              -13.3         Complies
 Peak Power Spectral Density per CFR 47 15.247                      -9.9         Complies


Environmental Conditions
        Ambient Temperature            24.5° C
        Relative Humidity              46%
        Atmospheric Pressure           1011.0 mb
Equipment Tested
Equipment                      Model                                 FCC I.D.
EUT                            RBSXTG-2HnD                           TV7SXTG-2HND
AC Adapter                     FLD181-240075-U                       N/A
Dell Studio XPS                921LBN1                               N/A
Rogers Labs, Inc.              Mikrotikls SIA
4405 W. 259th Terrace          Model: RBSXTG-2HnD                            SN: 399501DD0C31
Louisburg, KS 66053            Test #: 120716                                FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.247)                       Date: July 31, 2012
Revision 1                     File: Mikrotikls RBSXTG2HnD TstRpt 120716     Page 5 of 30


NVLAP Lab Code 200087-0

Application for Certification
(1)     Manufacturer:          Mikrotikls SIA
                               Pernavas 46
                               Riga, Latvia LV-1009

(2)     Identification:        Model: RBSXTG-2HnD

        FCC I.D.: TV7SXTG-2HND

(3)     Instruction Book:

        Refer to Exhibit for Instruction Manual.

(4)     Description of Circuit Functions:

        Refer to Exhibit of Operational Description.

(5)     Block Diagram with Frequencies:

        Refer to Exhibit of Operational Description.

(6)     Report of Measurements:

        Report of measurements follows in this Report.

(7)     Photographs: Construction, Component Placement, etc.:

        Refer to Exhibit for photographs of equipment.

(8)     List of Peripheral Equipment Necessary for operation. The equipment operates from power
        received from authorized AC/DC power adapter. The EUT offers connection ports for
        network interface only and requires Power Over Ethernet (POE) power for operation.
        During testing, the EUT was connected to CPU through network cable. The EUT received
        power supplied from external AC/DC supply connected to POE adapter.

(9)     Transition Provisions of CFR47 15.37 are not requested.

(10)    Not Applicable. The unit is not a scanning receiver.

(11)    Not Applicable. The EUT does not operate in the 59 – 64 GHz frequency band.

(12)    The equipment is not software defined and this section is not applicable.



Rogers Labs, Inc.              Mikrotikls SIA
4405 W. 259th Terrace          Model: RBSXTG-2HnD                           SN: 399501DD0C31
Louisburg, KS 66053            Test #: 120716                               FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.247)                      Date: July 31, 2012
Revision 1                     File: Mikrotikls RBSXTG2HnD TstRpt 120716    Page 6 of 30


NVLAP Lab Code 200087-0

Applicable Standards & Test Procedures

In accordance with the Federal Communications Code of Federal Regulations, dated October 1,
2011, Part 2, Subpart J, Paragraphs 2.907, 2.911, 2.913, 2.925, 2.926, 2.1031 through 2.1057,
and applicable parts of paragraph 15, Part 15C Paragraph 15.247 the following information is
submitted. Test procedures used are the established Methods of Measurement of Radio-Noise
Emissions as described in the ANSI C63.4-2009 Document, FCC documents KDB 662911 and
KDB 558074. Testing for the AC line-conducted emissions were performed as defined in
sections 7 and 13.1.3, testing of the radiated emissions was performed as defined in sections 8
and 13.1.4 of ANSI C63.4-2009. Testing of the intentional radiated emissions was performed as
defined in section 13 of ANSI C63.4-2009.


Equipment Function and Configuration
The EUT is a 2412-2462 MHz Digital Transmission System used to transmit data in applications
offering broadband wireless connectivity. The equipment is marketed for use to incorporate a
wireless link to exchange data information from one point to another. For testing purposes, the
RBSXTG-2HnD transceiver was connected to the manufacturer supplied POE and AC/DC
supply and communicating to the laptop computer through network interface. This configuration
offered operational control of the transmitter and communications over the network interface
between the EUT and supporting computer system. The RBSXTG-2HnD receives power from
the supplied POE and AC/DC adapter connected to utility power systems. The EUT offers
connection port for network interface only and requires power supplied from external source
AC/DC adapter and POE, no other interfacing options are provided. For testing purposes, the
RBSXTG-2HnD received powered from the AC/DC supply and configured to transmit in
available data modes. The device is produced with integral antenna system only. The antenna
system complies with requirements for unique antenna connection port.




Rogers Labs, Inc.             Mikrotikls SIA
4405 W. 259th Terrace         Model: RBSXTG-2HnD                           SN: 399501DD0C31
Louisburg, KS 66053           Test #: 120716                               FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214     Test to: CFR47 (15.247)                      Date: July 31, 2012
Revision 1                    File: Mikrotikls RBSXTG2HnD TstRpt 120716    Page 7 of 30


NVLAP Lab Code 200087-0

Equipment Configuration


        RouterBOARD
                                         Network Cable                 Laptop Computer
         SXTG-2HnD                                                          (CPU)
           (EUT)

                                                                       CPU AC Power
                                                                         Adapter
          POE and
        AC/DC Adapter
                                                                           Utility Power



Test Site Locations
Conducted EMI           The AC power line conducted emissions testing performed in a shielded
                        screen room located at Rogers Labs, Inc., 4405 W. 259th Terrace,
                        Louisburg, KS

Radiated EMI            The radiated emissions tests were performed at the 3 meters, Open Area
                        Test Site (OATS) located at Rogers Labs, Inc., 4405 W. 259th Terrace,
                        Louisburg, KS

Site Registration       Refer to Annex for Site Registration Letters

NVLAP Accreditation            Lab code 200087-0


Units of Measurements
Conducted EMI           Data is in dBµV; dB referenced to one microvolt

Radiated EMI            Data is in dBµV/m; dB/m referenced to one microvolt per meter

Sample Calculation:
             RFS = Radiated Field Strength, FSM = Field Strength Measured
             A.F. = Receive antenna factor, Gain = amplification gains and/or cable losses
             RFS (dBµV/m @ 3m) = FSM (dBµV) + A.F. (dB) - Gain (dB)
Rogers Labs, Inc.              Mikrotikls SIA
4405 W. 259th Terrace          Model: RBSXTG-2HnD                             SN: 399501DD0C31
Louisburg, KS 66053            Test #: 120716                                 FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.247)                        Date: July 31, 2012
Revision 1                     File: Mikrotikls RBSXTG2HnD TstRpt 120716      Page 8 of 30


NVLAP Lab Code 200087-0

Test Procedures
AC Line Conducted Emission Test Procedure

The EUT operates from DC power only and must be connected to an approved AC/DC adapter
for operation. For testing purposes, the manufacturer supplied AC/DC power adapter was used
to power the EUT and system. Testing for the AC line-conducted emissions testing was
performed as defined in sections 7 and 13.1.3 of ANSI C63.4-2009. The test setup including the
EUT was arranged in typical equipment configurations and placed on a 1 x 1.5-meter wooden
bench, 0.8 meters high located in a screen room. The power lines of the system were isolated
from the power source using a standard LISN with a 50-µHy choke. EMI was coupled to the
spectrum analyzer through a 0.1 µF capacitor internal to the LISN. The LISN was positioned on
the floor beneath the wooden bench supporting the EUT. The power lines and cables were
draped over the back edge of the table.

Radiated Emission Test Procedure

The EUT was placed on a rotating 1 x 1.5-meter wooden platform, 0.8 meters above the ground
plane at a distance of 3 meters from the FSM antenna. Testing for the radiated emissions was
performed as required by CFR47 15 and specified in sections 8 and 13.1.4 of ANSI C63.4-2009.
EMI energy was maximized by equipment placement, raising and lowering the FSM antenna,
changing the antenna polarization, and by rotating the turntable. Each emission was maximized
before data was taken using a spectrum analyzer. Refer to photographs in the test setup exhibits
for EUT placement during testing.




Rogers Labs, Inc.             Mikrotikls SIA
4405 W. 259th Terrace         Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053           Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214     Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                    File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 9 of 30


NVLAP Lab Code 200087-0

List of Test Equipment

A Rohde and Schwarz ESU40 and/or Hewlett Packard 8591EM was used as the measuring device
for the emissions testing of frequencies below 1 GHz. A Rohde and Schwarz ESU40 and/or
Hewlett Packard 8562A Spectrum Analyzer was used as the measuring device for testing the
emissions at frequencies above 1 GHz. The analyzer settings used are described in the following
table. Refer to the appendix for a complete list of test equipment.



                       AC Line Conducted Emissions (0.150 -30 MHz)
              RBW                         AVG. BW                     Detector Function
              9 kHz                         30 kHz                    Peak / Quasi Peak
                                  Emissions (30-1000 MHz)
              RBW                         AVG. BW                     Detector Function
            120 kHz                        300 kHz                    Peak / Quasi Peak
                                Emissions (Above 1000 MHz)
              RBW                         Video BW                    Detector Function
            100 kHz                        100 kHz                            Peak
             1 MHz                          1 MHz                      Peak / Average


Equipment       Manufacturer           Model                          Calibration Date     Due
LISN            Comp. Design           FCC-LISN-2-MOD.CD              10/11                10/12
Antenna         ARA                    BCD-235-B                      10/11                10/12
Antenna         EMCO                   3147                           10/11                10/12
Antenna         EMCO                   3147                           10/11                10/12
Antenna         Com Power              AH-118                         10/11                10/12
Analyzer        HP                     8591EM                         5/12                 5/13
Analyzer        HP                     8562A                          5/12                 5/13
Analyzer        Rohde & Schwarz        ESU40                          5/12                 5/13




Rogers Labs, Inc.              Mikrotikls SIA
4405 W. 259th Terrace          Model: RBSXTG-2HnD                              SN: 399501DD0C31
Louisburg, KS 66053            Test #: 120716                                  FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.247)                         Date: July 31, 2012
Revision 1                     File: Mikrotikls RBSXTG2HnD TstRpt 120716       Page 10 of 30


NVLAP Lab Code 200087-0

Intentional Radiators

As per CFR47, Subpart C, paragraph 15.247 the following information is submitted.

Antenna Requirements

The EUT incorporates integral antenna system and offers no provision for connection to alternate
system. The antenna connection point complies with the unique antenna connection requirements.
The requirements of 15.203 are fulfilled; there are no deviations or exceptions to the specification.

Restricted Bands of Operation

Spurious emissions falling in the restricted frequency bands of operation were measured at a
distance of three meters on the OATS. Measurements were made for each antenna option.
Emissions other than transmitter harmonics measured similar for all configurations and are
presented below. Harmonic emissions, in restricted bands, were measured for each antenna offered
and recorded. The EUT utilizes frequency, determining circuitry, which generates harmonics
falling in the restricted bands. Emissions were measured at the OATS, using appropriate antennas
or pyramidal horns, amplification stages, and a spectrum analyzer. No other significant emission
was observed which fell into the restricted bands of operation.




Rogers Labs, Inc.              Mikrotikls SIA
4405 W. 259th Terrace          Model: RBSXTG-2HnD                              SN: 399501DD0C31
Louisburg, KS 66053            Test #: 120716                                  FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.247)                         Date: July 31, 2012
Revision 1                     File: Mikrotikls RBSXTG2HnD TstRpt 120716       Page 11 of 30


NVLAP Lab Code 200087-0

General Radiated Emissions in Restricted Bands Data (General)
   Frequency in   Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
      MHz           Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average     (dBµV/m)
                  (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

     113.0          39.9         34.5         N/A         34.9         28.0         N/A         43.5

     125.0          42.3         39.7         N/A         34.3         31.9         N/A         43.5

     165.2          36.7         30.8         N/A         24.7         20.2         N/A         43.5

     250.0          41.3         37.4         N/A         33.1         30.5         N/A         46.0

     400.0          42.0         34.8         N/A         43.8         35.7         N/A         46.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded above for frequency range of 30-1000 MHz. Peak and
Average amplitude emissions are recorded above for frequency range above 1000 MHz.

Harmonic Radiated Emissions in Restricted Bands Data
   Frequency in   Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
      MHz           Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average     (dBµV/m)
                  (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

    2390.0          61.1         N/A          50.2        63.4         N/A         53.0         54.0

    2483.5          64.9         N/A          51.4        63.7         N/A         52.5         54.0

    4824.0          50.1         N/A          37.4        50.6         N/A         37.5         54.0

    4874.0          49.7         N/A          37.1        50.0         N/A         37.2         54.0

    4924.0          54.0         N/A          16.6        16.1         N/A         37.3         54.0

    7236.0          59.8         N/A          37.5        61.6         N/A         38.0         54.0

    7311.0          59.0         N/A          36.6        59.8         N/A         36.9         54.0

    7386.0          54.0         N/A          16.6        16.1         N/A         36.0         54.0

    12060.0         50.2         N/A          37.4        50.3         N/A         37.4         54.0

    12185.0         48.2         N/A          35.4        48.5         N/A         35.6         54.0

    12310.0         49.6         N/A          35.8        48.3         N/A         35.4         54.0

    14472.0         51.9         N/A          39.5        52.2         N/A         39.6         54.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded above for frequency range of 30-1000 MHz. Peak and
Average amplitude emissions are recorded above for frequency range above 1000 MHz.

Rogers Labs, Inc.                 Mikrotikls SIA
4405 W. 259th Terrace             Model: RBSXTG-2HnD                                 SN: 399501DD0C31
Louisburg, KS 66053               Test #: 120716                                     FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214         Test to: CFR47 (15.247)                            Date: July 31, 2012
Revision 1                        File: Mikrotikls RBSXTG2HnD TstRpt 120716          Page 12 of 30


NVLAP Lab Code 200087-0

Summary of Results for Radiated Emissions in Restricted Bands

The EUT demonstrated compliance with the radiated emissions requirements of CFR 47 Part
15C Intentional Radiators. The EUT demonstrated a minimum margin of -1.0 dB below the
radiated emissions requirements in restricted frequency bands. Peak, Quasi-peak, and average
amplitudes were checked for compliance with the regulations. Worst-case emissions are
reported with other emissions found in the restricted frequency bands at least 20 dB below the
requirements.

AC Line Conducted Emissions Procedure

The EUT was arranged in a typical equipment configuration and placed on a 1 x 1.5-meter
wooden bench 80 cm above the conducting ground plane, floor of a screen room. The bench was
positioned 40 cm away from the wall of the screen room. The LISN was positioned on the floor
of the screen room 80-cm from the rear of the EUT. The manufacturer supplied AC power
adapter for the EUT was connected to the LISN. A second LISN was positioned on the floor of
the screen room 80-cm from the rear of the supporting equipment of the EUT. All power cords
except the EUT were then powered from the second LISN. EMI was coupled to the spectrum
analyzer through a 0.1 μF capacitor, internal to the LISN. Power line conducted emissions
testing were carried out individually for each current carrying conductor of the EUT. The excess
length of lead between the system and the LISN receptacle was folded back and forth to form a
bundle not exceeding 40 cm in length. The screen room, conducting ground plane, analyzer, and
LISN were bonded together to the protective earth ground. Preliminary testing was performed to
identify the frequency of each radio frequency emission displaying the highest amplitude. The
cables were repositioned to obtain maximum amplitude of measured EMI level. Once the worst-
case configuration was identified, plots were made of the EMI from 0.15 MHz to 30 MHz then
the data was recorded with maximum conducted emissions levels. Refer to figures one and two
for plots of the EUT powered by POE and AC/DC adapter, AC Power Line conducted emissions.




Rogers Labs, Inc.            Mikrotikls SIA
4405 W. 259th Terrace        Model: RBSXTG-2HnD                           SN: 399501DD0C31
Louisburg, KS 66053          Test #: 120716                               FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214    Test to: CFR47 (15.247)                      Date: July 31, 2012
Revision 1                   File: Mikrotikls RBSXTG2HnD TstRpt 120716    Page 13 of 30


NVLAP Lab Code 200087-0




Figure One AC Line Conducted Emissions Line 1




Figure Two AC Line Conducted Emissions Line 2

Rogers Labs, Inc.           Mikrotikls SIA
4405 W. 259th Terrace       Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053         Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214   Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                  File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 14 of 30


NVLAP Lab Code 200087-0

AC Line Conducted Emissions Data (Highest Emissions)
Line 1




Line 2




Other emissions present had amplitudes at least 20 dB below the limit.

Summary of Results for AC Line Conducted Emissions

The EUT demonstrated compliance to the conducted emissions requirements of CFR47 Part 15C
equipment. The EUT demonstrated minimum margin of -111.0 dB below the limit.
Measurements were taken using the peak, quasi peak, and average, measurement function for
each emissions amplitude and were below the limits stated in the specification. Other emissions
were present with recorded data representing worst-case amplitudes.

Rogers Labs, Inc.            Mikrotikls SIA
4405 W. 259th Terrace        Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053          Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214    Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                   File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 15 of 30


NVLAP Lab Code 200087-0

General Radiated Emissions Procedure

The EUT was arranged in a typical equipment configuration and operated through all available
modes with worst-case data recorded. Preliminary testing was performed in a screen room with
the EUT positioned 1 meter from the FSM. Radiated emissions measurements were performed
to identify the frequencies, which produced the highest emissions. Plots were made of the
radiated frequency spectrum from 30 MHz to 25,000 MHz for the preliminary testing. Each
radiated emission was then maximized at the OATS location before final radiated emissions
measurements were performed. Final data was taken with the EUT located at the OATS at a
distance of 3 meters between the EUT and the receiving antenna. The frequency spectrum from
9 kHz to 25,000 MHz was searched for general radiated emissions. Measured emission levels
were maximized by EUT placement on the table, rotating the turntable through 360 degrees,
varying the antenna height between 1 and 4 meters above the ground plane and changing antenna
position between horizontal and vertical polarization. Antennas used were Loop from 9 kHz to
30 MHz, Broadband Biconical from 30 to 200 MHz, Biconilog from 30 to 1000 MHz, Log
Periodic from 200 MHz to 1 GHz and or double Ridge or pyramidal horns and mixers from 1
GHz to 40 GHz, notch filters and appropriate amplifiers and external mixers were utilized.




Rogers Labs, Inc.            Mikrotikls SIA
4405 W. 259th Terrace        Model: RBSXTG-2HnD                           SN: 399501DD0C31
Louisburg, KS 66053          Test #: 120716                               FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214    Test to: CFR47 (15.247)                      Date: July 31, 2012
Revision 1                   File: Mikrotikls RBSXTG2HnD TstRpt 120716    Page 16 of 30


NVLAP Lab Code 200087-0

General Radiated Emissions from EUT Data (Highest Emissions)
   Frequency in   Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
      MHz           Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average     (dBµV/m)
                  (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)
     49.2        39.8       28.8      N/A         41.7       34.5        N/A         40.0
     49.5        35.3       28.6      N/A         41.7       34.5        N/A         40.0
     62.5        34.1       28.5      N/A         70.5       33.8        N/A         40.0
     75.5        33.4       28.2      N/A         39.9       34.5        N/A         40.0
     78.4        34.3       28.4      N/A         37.7       34.8        N/A         40.0
     80.4        32.3       26.5      N/A         38.1       34.9        N/A         40.0
    105.3        41.4       33.7      N/A         36.3       31.6        N/A         43.5
    113.0        39.9       34.5      N/A         34.9       28.0        N/A         43.5
    125.0        42.3       39.7      N/A         34.3       31.9        N/A         43.5
    149.4        36.1       30.6      N/A         33.7       27.9        N/A         43.5
    151.8        36.8       31.2      N/A         31.2       25.7        N/A         43.5
    159.0        35.8       31.2      N/A         27.1       20.7        N/A         43.5
    165.2        36.7       30.8      N/A         24.7       20.2        N/A         43.5
    179.0        38.3       32.1      N/A         29.0       23.7        N/A         43.5
    181.1        37.5       32.0      N/A         29.1       23.6        N/A         43.5
    204.0        38.0       32.8      N/A         33.5       28.9        N/A         43.5
    214.9        35.6       30.9      N/A         34.4       28.7        N/A         43.5
    233.6        33.9       28.1      N/A         31.7       25.6        N/A         46.0
    238.6        32.2       25.5      N/A         31.1       25.4        N/A         46.0
    250.0        41.3       37.4      N/A         33.1       30.5        N/A         46.0
    299.3        25.7       20.2      N/A         28.7       23.2        N/A         46.0
    400.0        42.0       34.8      N/A         43.8       35.7        N/A         46.0
    800.0        44.6       43.4      N/A         40.6       39.3        N/A         46.0
    875.0        33.2       28.1      N/A         35.4       28.4        N/A         46.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded above for frequency range of 30-1000 MHz. Peak and
Average amplitude emissions are recorded above for frequency range above 1000 MHz.

Summary of Results for General Radiated Emissions

The EUT demonstrated compliance with the radiated emissions requirements of CFR47 Part 15C
paragraph 15.209 Intentional Radiators. The EUT demonstrated a minimum margin of -2.6 dB
below the requirements. Other emissions were present with amplitudes at least 20 dB below the
Limits.


Rogers Labs, Inc.                 Mikrotikls SIA
4405 W. 259th Terrace             Model: RBSXTG-2HnD                                SN: 399501DD0C31
Louisburg, KS 66053               Test #: 120716                                    FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214         Test to: CFR47 (15.247)                           Date: July 31, 2012
Revision 1                        File: Mikrotikls RBSXTG2HnD TstRpt 120716         Page 17 of 30


NVLAP Lab Code 200087-0

Operation in the Band 2400 – 2483.5 MHz

The power output was measured at the open area test site at a three-meter distance. The EUT was
placed on a wooden turntable 0.8 meters above the ground plane at a distance of 3 meters from the
FSM antenna. The peak and quasi-peak amplitude of the frequencies below 1000 MHz were
measured using a spectrum analyzer. The peak and average amplitude of emissions above 1000
MHz including were measured using a spectrum analyzer. Emissions data was recorded from the
measurement results. Plots were made of transmitter performance for reference purposes. Refer to
figures three through eight showing plots taken of the EUT performance displaying compliance with
the specifications. As this product utilizes permanently attached antenna and offers no provision for
antenna port measurements. Test procedures as defined in publications KDB 558074 and ANSI
C63.10-2009 were utilized for compliance testing. These procedures utilize measurement of
maximum field strength and conversion calculation for comparison with requirements.

    1. Calculate the transmitter's peak power using the following equation:
                P = (E * d)2 / (30 * G)
       Where: E = the measured maximum field strength in V/m.
               G = the numeric gain of the transmitting antenna over an isotropic radiator.
               d = the distance in meters from which the field strength was measured.
               P = the power in watts
       Setting the RBW > 6dB bandwidth of the emission or using a peak power meter

    2. Emission Bandwidth was measured in compliance with KDB 558074 paragraph 5.1.1.
    3. Maximum Peak Output Power was measured in compliance with KDB 558074 paragraph
       5.2.1.2.
    4. Maximum Power Spectral Density was measured in compliance with KDB 558074
       paragraph 5.3.1.
    5. Maximum Unwanted Emissions Levels were measured in compliance with KDB 558074
       and CFR47 paragraph 15C at 3-meters distance located on the OATS.




Rogers Labs, Inc.             Mikrotikls SIA
4405 W. 259th Terrace         Model: RBSXTG-2HnD                           SN: 399501DD0C31
Louisburg, KS 66053           Test #: 120716                               FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214     Test to: CFR47 (15.247)                      Date: July 31, 2012
Revision 1                    File: Mikrotikls RBSXTG2HnD TstRpt 120716    Page 18 of 30


NVLAP Lab Code 200087-0




Figure Three Plot of Transmitter Emissions (Across Operational Band, 5 MHz Mode)




Figure Four Plot of Transmitter Emissions (Across Operational Band, 10 MHz Mode)

Rogers Labs, Inc.           Mikrotikls SIA
4405 W. 259th Terrace       Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053         Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214   Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                  File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 19 of 30


NVLAP Lab Code 200087-0




Figure Five Plot of Transmitter Emissions (Across Operational Band, 20 MHz Mode)




Figure Six Plot of Transmitter Emissions (Across Operational Band, 40 MHz Mode)

Rogers Labs, Inc.           Mikrotikls SIA
4405 W. 259th Terrace       Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053         Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214   Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                  File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 20 of 30


NVLAP Lab Code 200087-0




Figure Seven Plot of Low Band Edge




Figure Eight Plot of High Band Edge

Rogers Labs, Inc.           Mikrotikls SIA
4405 W. 259th Terrace       Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053         Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214   Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                  File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 21 of 30


NVLAP Lab Code 200087-0

Transmitter Emissions Data

Calculated Transmitter Antenna Port Power

   Frequency       Calculated Conducted Antenna       Occupied             Calculated Power Spectral
     MHz            Port Output Power (Watts)      Bandwidth (kHz)              Density (dBm)

                                            20 MHz Channel

      2412                     1.0                      16,667                       -1.9

      2437                     1.0                      16,588                       -2.8

      2462                     0.9                      16,667                       -2.9

                                            40 MHz Channel

      2422                     0.9                      37,500                       -3.5

      2447                     0.9                      37,019                       -3.7

      2452                     0.9                      36,779                       -4.3




Rogers Labs, Inc.              Mikrotikls SIA
4405 W. 259th Terrace          Model: RBSXTG-2HnD                            SN: 399501DD0C31
Louisburg, KS 66053            Test #: 120716                                FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.247)                       Date: July 31, 2012
Revision 1                     File: Mikrotikls RBSXTG2HnD TstRpt 120716     Page 22 of 30


NVLAP Lab Code 200087-0

Transmitter Radiated Emission

  Frequency in     Horizontal        Horizontal      Vertical Peak   Vertical Average   Limit @ 3m
     MHz         Peak (dBµV/m)    Average (dBµV/m)    (dBµV/m)          (dBµV/m)         (dBµV/m)

    2412.0           128.2             116.4            127.0            115.0              --

    4824.0            50.1             37.4             50.6              37.5            54.0

    7236.0            59.8             37.5             61.6              38.0            54.0

    9648.0            51.2             39.0             51.5              39.0            54.0

    12060.0           50.2             37.4             50.3              37.4            54.0

    14472.0           51.9             39.5             52.2              39.6            54.0

    16884.0           51.2             38.7             51.3              38.7            54.0

    2437.0           128.1             116.5            126.7            115.0              --

    4874.0            49.7             37.1             50.0              37.2            54.0

    7311.0            59.0             36.6             59.8              36.9            54.0

    9748.0            50.9             38.0             50.4              37.9            54.0

    12185.0           48.2             35.4             48.5              35.6            54.0

    14622.0           51.3             38.7             51.4              38.8            54.0

    17059.0           51.9             38.6             51.1              38.6            54.0

    2462.0           128.0             114.7            126.0            115.1              --

    4924.0            50.2             37.1             50.2              37.3            54.0

    7386.0            58.4             35.7             59.3              36.0            54.0

    9848.0            50.0             37.3             49.9              37.1            54.0

    12310.0           49.6             35.8             48.3              35.4            54.0

    14772.0           52.9             40.7             52.9              40.6            54.0

    17234.0           53.2             40.2             53.3              40.2            54.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded above for frequency range of 30-1000 MHz. Peak and
Average amplitude emissions are recorded above for frequency range above 1000 MHz.


Rogers Labs, Inc.                Mikrotikls SIA
4405 W. 259th Terrace            Model: RBSXTG-2HnD                               SN: 399501DD0C31
Louisburg, KS 66053              Test #: 120716                                   FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214        Test to: CFR47 (15.247)                          Date: July 31, 2012
Revision 1                       File: Mikrotikls RBSXTG2HnD TstRpt 120716        Page 23 of 30


NVLAP Lab Code 200087-0

Summary of Results for Transmitter Radiated Emissions of Intentional Radiator

The EUT demonstrated compliance with the radiated emissions requirements of CFR47 Part
15.247. Calculated Antenna port conducted power of 30.0 dBm, 1.0 Watts. The peak power
spectral density presented a minimum margin of -9.9 dB below the requirements. The EUT
demonstrated a minimum margin of -13.3 dB below the harmonic emissions requirements.
There were no other significantly measurable emissions in the restricted bands other than those
recorded in this report. Other emissions were present with amplitudes at least 20 dB below the
requirements. There were no other deviations or exceptions to the requirements.


Statement of Modifications and Deviations

No modifications to the EUT were required for the unit to demonstrate compliance with the
CFR47 Part 15C emissions standards. There were no deviations to the specifications.




Rogers Labs, Inc.            Mikrotikls SIA
4405 W. 259th Terrace        Model: RBSXTG-2HnD                           SN: 399501DD0C31
Louisburg, KS 66053          Test #: 120716                               FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214    Test to: CFR47 (15.247)                      Date: July 31, 2012
Revision 1                   File: Mikrotikls RBSXTG2HnD TstRpt 120716    Page 24 of 30


NVLAP Lab Code 200087-0


Annex

   Annex A Measurement Uncertainty Calculations

   Annex B Rogers Labs Test Equipment List

   Annex C Rogers Qualifications

   Annex D FCC Site Registration Letter

   Annex E Industry Canada Site Registration Letter




Rogers Labs, Inc.            Mikrotikls SIA
4405 W. 259th Terrace        Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053          Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214    Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                   File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 25 of 30


NVLAP Lab Code 200087-0

Annex A Measurement Uncertainty Calculations

Measurement uncertainty calculations were made for the laboratory. Result of measurement
uncertainty calculations are recorded below for AC line conducted and radiated emission
measurements.

Measurement Uncertainty                                         U(E)              U(lab)

3 Meter Horizontal 30-200 MHz Measurements                      2.08              4.16

3 Meter Vertical 30-200 MHz Measurements                        2.16              4.33

3 Meter Vertical Measurements 200-1000 MHz                      2.99              5.97

10 Meter Horizontal Measurements 30-200 MHz                     2.07              4.15

10 Meter Vertical Measurements 30-200 MHz                       2.06              4.13

10 Meter Horizontal Measurements 200-1000 MHz                   2.32              4.64

10 Meter Vertical Measurements 200-1000 MHz                     2.33              4.66

3 Meter Measurements 1-6 GHz                                    2.57              5.14

3 Meter Measurements 6-18 GHz                                   2.58              5.16

AC Line Conducted                                               1.72              3.43




Rogers Labs, Inc.            Mikrotikls SIA
4405 W. 259th Terrace        Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053          Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214    Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                   File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 26 of 30


NVLAP Lab Code 200087-0


Annex B Rogers Labs Test Equipment List
The test equipment is maintained in calibration and good operating condition. Use of this
calibrated equipment ensures measurements are traceable to national standards.
List of Test Equipment                                                    Calibration Date
Spectrum Analyzer: Rohde & Schwarz ESU40                                         5/12
Spectrum Analyzer: HP 8562A, HP Adapters: 11518, 11519, and 11520                5/12
        Mixers: 11517A, 11970A, 11970K, 11970U, 11970V, 11970W
Spectrum Analyzer: HP 8591EM                                                     5/12
Antenna: EMCO Biconilog Model: 3143                                              5/12
Antenna: Sunol Biconilog Model: JB6                                              10/11
Antenna: EMCO Log Periodic Model: 3147                                           10/11
Antenna: Antenna Research Biconical Model: BCD 235                               10/11
LISN: Compliance Design Model: FCC-LISN-2.Mod.cd, 50 μHy/50 ohm/0.1 µf 10/11
R.F. Preamp CPPA-102                                                             10/11
Attenuator: HP Model: HP11509A                                                   10/11
Attenuator: Mini Circuits Model: CAT-3                                           10/11
Attenuator: Mini Circuits Model: CAT-3                                           10/11
Cable: Belden RG-58 (L1)                                                         10/11
Cable: Belden RG-58 (L2)                                                         10/11
Cable: Belden 8268 (L3)                                                          10/11
Cable: Time Microwave: 4M-750HF290-750                                           10/11
Cable: Time Microwave: 10M-750HF290-750                                          10/11
Frequency Counter: Leader LDC825                                                 2/12
Oscilloscope Scope: Tektronix 2230                                               2/12
Wattmeter: Bird 43 with Load Bird 8085                                           2/12
Power Supplies: Sorensen SRL 20-25, SRL 40-25, DCR 150, DCR 140                  2/12
R.F. Generators: HP 606A, HP 8614A, HP 8640B                                     2/12
 R.F. Power Amp 65W Model: 470-A-1010                                            2/12
R.F. Power Amp 50W M185- 10-501                                                  2/12
R.F. Power Amp A.R. Model: 10W 1010M7                                            2/12
R.F. Power Amp EIN Model: A301                                                   2/12
LISN: Compliance Eng. Model 240/20                                               2/12
LISN: Fischer Custom Communications Model: FCC-LISN-50-16-2-08                   2/12
Antenna: EMCO Dipole Set 3121C                                                   2/12
Antenna: C.D. B-101                                                              2/12
Antenna: Solar 9229-1 & 9230-1                                                   2/12
Antenna: EMCO 6509                                                               2/12
Audio Oscillator: H.P. 201CD                                                     2/12
Peavey Power Amp Model: IPS 801                                                  2/12
ELGAR Model: 1751                                                                2/12
ELGAR Model: TG 704A-3D                                                          2/12
ESD Test Set 2010i                                                               2/12
Fast Transient Burst Generator Model: EFT/B-101                                  2/12
Field Intensity Meter: EFM-018                                                   2/12
KEYTEK Ecat Surge Generator                                                      2/12
Shielded Room 5 M x 3 M x 3.0 M
Rogers Labs, Inc.            Mikrotikls SIA
4405 W. 259th Terrace        Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053          Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214    Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                   File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 27 of 30


NVLAP Lab Code 200087-0


Annex C Rogers Qualifications

Scot D. Rogers, Engineer

Rogers Labs, Inc.

Mr. Rogers has approximately 17 years experience in the field of electronics. Engineering
experience includes six years in the automated controls industry and remaining years working
with the design, development and testing of radio communications and electronic equipment.

Positions Held

        Systems Engineer:      A/C Controls Mfg. Co., Inc. 6 Years

        Electrical Engineer:   Rogers Consulting Labs, Inc. 5 Years

        Electrical Engineer:   Rogers Labs, Inc. Current

Educational Background

1)      Bachelor of Science Degree in Electrical Engineering from Kansas State University.

2)      Bachelor of Science Degree in Business Administration Kansas State University.

3)      Several Specialized Training courses and seminars pertaining to Microprocessors and
        Software programming.



Scot D. Rogers




Rogers Labs, Inc.              Mikrotikls SIA
4405 W. 259th Terrace          Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053            Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                     File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 28 of 30


                      FEDERAL COMMUNICATIONS COMMISSION
                                                Laboratory Division
                                             7435 Oakland Mills Road
                                               Columbia, MD21046
                                                November 01. 2011

              |                                                                            Registration Number: 90910
Rogers Labs, Inc.
4405 West 259th Terrace,
Louisburg, KS 66053

Attention:          Scot Rogers,

Re:                 Measurement facilitylocated at Louisburg _
                    3 & 10 meter site
                    Date of Renewal: November 01, 201 1

Dear Sir or Madam:

Your request for renewal of the registration of the subject measurement facility has been received. The information
submitted has been placed in your file and the registration has been renewed. The name of your organization will
remain on the list of facilities whose measurement data will be accepted in conjunction with applications for
Certification under Parts 15 or 18 of the Cormmssmns Rutes. Pleasenote that the file must be updated for any
changes made to the facility and the teglstranmnmust be renewedat least every three years

Measurement facilities that have indicated that they are avaliable to the public to performmeasurement services ona
fee basis may be found on the FCC website www.fec.gov under E—Filing, OET Equipment Authorlz:atwn Electronic
Filing, Test Firms.


                                                                        Sincerely,



                                                                        Phyillis Pérrish
                                                                        Industry Analyst


NVLAP Lab Code 200087-0


Annex E Industry Canada Site Registration Letter




Rogers Labs, Inc.           Mikrotikls SIA
4405 W. 259th Terrace       Model: RBSXTG-2HnD                          SN: 399501DD0C31
Louisburg, KS 66053         Test #: 120716                              FCC ID#: TV7SXTG-2HND
Phone/Fax: (913) 837-3214   Test to: CFR47 (15.247)                     Date: July 31, 2012
Revision 1                  File: Mikrotikls RBSXTG2HnD TstRpt 120716   Page 30 of 30



Document Created: 2012-07-31 12:37:31
Document Modified: 2012-07-31 12:37:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC