Test setup photos

FCC ID: TV7LHG5ACD

Test Setup Photos

Download: PDF
FCCID_3620774

         Company: MikroTik


    Product Name: 5aCD Module

Report No.: MIKO60 Test Setup Photos




      PHOTOS - TEST SETUP


                                            Title:         MIKO60 Module Test Setup Photos
                                              To:
                                         Serial #:
                                      Issue Date:          05 September 2017
                                           Page:           2 of 9




1. Test Setup Photographs
1.1.1. Test Setup




27dBi TX Spurious 1-18GHz




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


                                            Title:         MIKO60 Module Test Setup Photos
                                              To:
                                         Serial #:
                                      Issue Date:          05 September 2017
                                           Page:           3 of 9



1.1.2. Test Setup - RE#1 - Radiated Emissions - 3m Chamber




16dBi TX Spurious 1-18GHz




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


                                            Title:         MIKO60 Module Test Setup Photos
                                              To:
                                         Serial #:
                                      Issue Date:          05 September 2017
                                           Page:           4 of 9




9dBi TX Spurious 1-18GHz




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


                                            Title:         MIKO60 Module Test Setup Photos
                                              To:
                                         Serial #:
                                      Issue Date:          05 September 2017
                                           Page:           5 of 9




Transmitter Emissions 1-18GHz




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


                                            Title:         MIKO60 Module Test Setup Photos
                                              To:
                                         Serial #:
                                      Issue Date:          05 September 2017
                                           Page:           6 of 9




Transmitter Emissions 30M-1GHz




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


                                            Title:         MIKO60 Module Test Setup Photos
                                              To:
                                         Serial #:
                                      Issue Date:          05 September 2017
                                           Page:           7 of 9



1.1.3. Test Setup - RF#1 - Conducted




RF Conducted




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com





Document Created: 2017-09-05 12:07:40
Document Modified: 2017-09-05 12:07:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC