RF Exposure

FCC ID: T2C-W52P

RF Exposure Info

Download: PDF
FCCID_1914708

Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ120919003-00FP

FCC§ 15.319 (i) &2.1091 - RF RADIATION EXPOSURE
Limit
According to FCC §15.319(i) and §1.1307(b)(1), systems operating under the provisions of this section
shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in
excess of the Commission’s guidelines.

                   Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

      Frequency             Electric Field      Magnetic Field      Power Density            Averaging Time
     Range (MHz)           Strength (V/m)       Strength (A/m)       (mW/cm2)                   (minute)

                              Limits for General Population/Uncontrolled Exposure
        0.3-1.34                614                  1.63                *(100)                   30
        1.34-30                 842/f                2.19/f           *(180/f\2\)                 30
         30-300                 27.5                 0.073                0.2                     30
        300-1500                  /                    /                 f/1500                   30
      1500-100,000                /                    /                  1.0                     30

 f = frequency in MHz
 * = Plane-wave equivalent power density


MPE Calculation
Predication of MPE limit at a given distance

                                                 S = PG/4R2
Where: S = power density (in appropriate units, e.g. mW/cm2);
       P = power input to the antenna (in appropriate units, e.g., mW);
       G = power gain of the antenna in the direction of interest relative to an isotropic radiator
       R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);


  Frequency          Antenna Gain            Conducted Power     Evaluation         Power         MPE Limit
    (MHz)                                                         Distance         Density        (mW/cm2)
                   (dBi)     (numeric)       (dBm)     (mW)         (cm)          (mW/cm2)
   1921.536          0           1.0         20.07     101.62        20             0.0202             1
   1924.992          0           1.0         20.01     100.23       20              0.0199             1
   1928.448          0           1.0         19.96      99.08       20              0.0197             1

Result: The device meets MPE limit at 20 cm distance.




FCC Part 15D                                                                                       Page 9 of 49



Document Created: 2019-06-22 09:02:09
Document Modified: 2019-06-22 09:02:09

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC