Test Report

FCC ID: SZO-RR01

Test Report

Download: PDF
FCCID_2829289

                                     EMI − T E S T R E P O R T
                                                        - FCC Part 15.249, RSS 210 -


                 Type / Model Name                 : RR01


               Product Description                 : Active Timing System


                              Applicant            : race result AG

                                 Address           : Haid-und-Neu-Str. 7

                                                     76131 Karlsruhe

                                                     GERMANY


                         Manufacturer              : race result AG

                                 Address           : Haid-und-Neu-Str. 7

                                                     76131 Karlsruhe

                                                     GERMANY




       Test Result according to the standards
       listed in clause 1 test standards:
                                                                                    POSITIVE



                                                                                                      11. November 2015
        Test Report No. :                            T39567-00-02JP               ______________________________________________________________________________________________

                                                                                                                  Date of issue




                                                             The test report merely corresponds to the test sample.
                                                             It is not permitted to copy extracts of these test results
                                                             without the written permission of the test laboratory.




CSA Group Bayern GmbH                                                                    File No. T39567-00-02JP, page 1 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                                                                  Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                IC: 20465-RR01

                                                   Contents
       1     TEST ST AND ARDS                                                                          3

       2     EQUIPMENT UNDER TEST                                                                      4

       2.1     Photo documentation of the EUT – Detailed photos see attachment A                       4
       2.2     Short description of the equipment under test (EUT)                                     5
       2.3     Variants of the EUT                                                                     5
       2.4     Operation frequency and channel plan                                                    5
       2.5     EuT operation mode:                                                                     5
       2.6     Antenna                                                                                 5
       2.7     Power supply system utilised                                                            5
       2.8     Peripheral devices and interface cables                                                 6
       2.9     Determination of worst case conditions for final measurement                            6

       3     TEST RESULT SUMMERY                                                                       7

       3.1     Final assessment                                                                        7

       4     TEST ENVIRONMENT                                                                          8

       4.1     Address of the test laboratory                                                          8
       4.2     Environmental conditions                                                                8
       4.3     Statement of the measurement uncertainty                                                8
       4.4     Measurement protocol for FCC and IC                                                     9

       5     TEST CONDITIONS AND RESULTS                                                            10

       5.1     Field strength of fundamental                                                         10
       5.2     Out-of-band emission, radiated                                                        12
       5.3     EBW and OBW                                                                           16
       5.4     Correction for pulse operation (duty cycle)                                           21

       6     USED TEST EQUIPMENT AND ACCESSORIES                                                    24




CSA Group Bayern GmbH                                                 File No. T39567-00-02JP, page 2 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                          Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                       IC: 20465-RR01

1 TEST STANDARDS
The tests were performed according to following standards:

FCC Rules and Regulations Part 15, Subpart A - General (September, 2014)

FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September, 2014)
Part 15, Subpart C, Section 15.209           Radiated emission limits, general requirements
Part 15, Subpart C, Section 15.249           Operation within the bands 902 - 928 MHz, 2400 - 2483.5 MHz,
                                             5725 - 5875 MHz, and 24.0 - 24.25 GHz

RSS-Gen Issue 4, Nov 2014                          General Requirements and Information for the Certification of Radio
                                                   Apparatus

RSS-210 Issue 8, Dec 2010                          Licence-exempt Radio Apparatus (All Frequency Bands): Category I
                                                   Equipment


ANSI C63.10: 2013                                  Testing Unlicensed Wireless Devices


CISPR 16-4-2: 2013                                 Uncertainty in EMC measurement




CSA Group Bayern GmbH                                                         File No. T39567-00-02JP, page 3 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                   Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01     IC: 20465-RR01

2 EQUIPMENT UNDER TEST
 2.1     Photo documentation of the EUT




CSA Group Bayern GmbH                                    File No. T39567-00-02JP, page 4 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                             Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                           IC: 20465-RR01



 2.2     Short description of the equipment under test (EUT)

The activce timing system is used for time measurements in sport events and consists out of the RR02 (base
srarion) and the RR01 (transponder). The RR02s 125 kHz loop antenna is placed on the time measurement
position. The RR01 is mounted on the participant of the event or its equipment. The 125 kHz signal triggers a
2.4GHz transmission between the RR02 and the RR01. This message contains the required information and is
stored.
The functions of the RR01 are controlled by the 125 kHz signal of the RR02.

Number of tested samples:             1
Serial number:                        AETUN02 (modulated)
                                      KCBKM95 (unmodulated)


 2.3     Variants of the EUT
none


 2.4     Operation frequency and channel plan
                                 The operating frequency band is 2400 MHz to 2483.5 MHz.

Channel plan:

                                                       Channels   Frequency
                                                          0*        2480*
                                                          1*        2405*
                                                          2          2425
                                                          3          2475
                                                          4          2415
                                                          5          2460
                                                          6          2435
                                                          7*        2450*

* Frequencies tested.
2.5 EuT operation mode:
The equipment under test was operated during the measurement under the following conditions:

- 2.4GHz communication is active, 125kHz RFID reading is active



 2.6     Antenna
Internal antenna, not accesable by the end user


 2.7     Power supply system utilised
       Power supply voltage tag                    :   3V DC (battery suplied)




CSA Group Bayern GmbH                                                            File No. T39567-00-02JP, page 5 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                     Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                    IC: 20465-RR01


    2.8   Peripheral devices and interface cables
The following peripheral devices and interface cables are connected during the measurements:

-    none                                            Model :



    2.9   Determination of worst case conditions for final measurement

Measurement was made in all three orthogonal axes to locate the worst-case position. The results obtained in worst-
case position are noted in this report.




CSA Group Bayern GmbH                                                      File No. T39567-00-02JP, page 6 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                               IC: 20465-RR01

3 TEST RESULT SUMMERY

        FCC Rule Part              RSS Rule Part                             Description                     Result

            15.207                 RSS Gen, 8.8                AC power line conducted emissions        Not applicable1
            15.209                 RSS Gen, 8.9                 General radiated emission limits            passed
            15.215                      -                       Additional provisions (20dB BW)             passed
               -                   RSS-Gen, 6.6                 Occupied bandwidth (99% BW)                 passed
            15.249                 RSS-210, A2.9                 Field strength of fundamental              passed
1EuT is battery supplied




This test report deals with the 2.4 GHz DTS function of the EuT.


 3.1     Final assessment

The equipment under test fulfills the EMI requirements cited in clause 1 test standards.




Date of receipt of test sample                :    acc. to storage records


Testing commenced on                          :    08 April 2015


Testing concluded on                          :    26 October 2015


Checked by:                                                                      Tested by:

                           Klaus Gegenfurtner
                           I confirm the correctness
                                                                                                      Jürgen Pessinger
                           and Integrity of this                                                      2015.11.11
                           documents
                           2015.11.11 14:54:26 +01'00'                                                14:45:51 +01'00'
               Klaus Gegenfurtner                                                             Jürgen Pessinger
               Teamleader Radio




CSA Group Bayern GmbH                                                                 File No. T39567-00-02JP, page 7 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                          Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                   IC: 20465-RR01

4 TEST ENVIRONMENT
 4.1     Address of the test laboratory

           CSA Group Bayern GmbH
           Ohmstrasse 1-4
           94342 STRASSKIRCHEN
           GERMANY



 4.2     Environmental conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature:                                       15-35 ° C


Humidity:                                           30-60 %


Atmospheric pressure:                              86-106 kPa




 4.3     Statement of the measurement uncertainty

The data and results referenced in this document are true and accurate. It is noted that the expanded measurement
uncertainty corresponds to the measurement results from the standard measurement uncertainty multiplied by the
coverage factor k = 2. The true value is located in the corresponding interval with a probability of 95 % The
measurement uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16-4-2 /
11.2003 „Uncertainties, statistics and limit modelling – Uncertainty in EMC measurements“ and is documented in
the quality system acc. to DIN EN ISO/IEC 17025. For all measurements shown in this report, the measurement
uncertainty of the test laboratory, CSA Group Bayern GmbH, is below the measurement uncertainty as defined by
CISPR. Therefore, no special measures must be taken into consideration with regard to the limits according to
CISPR. Furthermore, component and process variability of devices similar to that tested may result in additional
deviation. The manufacturer has the sole responsibility of continued compliance of the device.




CSA Group Bayern GmbH                                                      File No. T39567-00-02JP, page 8 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                      IC: 20465-RR01

 4.4      Measurement protocol for FCC and IC
4.4.1 General information
4.4.1.1 Test methodology

Conducted and radiated disturbance testing is performed according to the procedures set out by the International
Special Committee on Radio Interference (CISPR) Publication 22, European Standard EN 55022 as shown under
section 1 of this report.

The Open Area test site is listed under the Canadian Test-Sites File-No:

                                                   IC 3009A-1
In compliance with RSS 210 testing for RSS compliance may be achieved by following the procedures set out in
ANSI C63.10 and applying the CISPR 22 limits.


4.4.1.2    Justification

The equipment under test (EUT) is configured in a typical user arrangement in accordance with the manufacturer's
instructions. A cable is connected to each available port and either terminated with a peripheral using the appropriate
impedance characteristic or left unterminated. Where appropriate, cables are manually manipulated with respect to
each other thus obtaining maximum disturbances from the unit.


4.4.1.3    Details of test procedures

The test methods used comply with CISPR Publication 22, EN 55022 - " Information technology equipment - Radio
disturbance characteristics - Limits and methods of measurement" and with ANSI C63.4 - "Methods of Measurement
of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz".
In compliance with 47 CFR Part 15 Subpart A, Section 15.38 testing for FCC compliance may be achieved by following
the procedures set out in ANSI C63.10 and applying the CISPR 22 limits.




CSA Group Bayern GmbH                                                         File No. T39567-00-02JP, page 9 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                    Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                   IC: 20465-RR01

5 TEST CONDITIONS AND RESULTS
 5.1     Field strength of fundamental
For test instruments and accessories used see section 6 Part CPR 3.
5.1.1    Description of the test location

Test location:                Anechoic chamber 1
Test distance:                3m

5.1.2    Photo documentation of the test set-up




5.1.1    Applicable standard

According to FCC Part 15C, Section 15.249 and RSS-210 A2.9:




CSA Group Bayern GmbH                                                 File No. T39567-00-02JP, page 10 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                           Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                           IC: 20465-RR01


5.1.2    Description of Measurement

The radiated emission of the fundamental wave from the EUT is measured using a spectrum analyser and appropriate
linear polarized antennas. The set up of the EUT and the measurement procedure is in accordance to ANSI C63.10,
Item 6.5. The EUT is measured in TX continuous mode unmodulated under normal conditions.

Analyser settings:
Peak measurement: RBW: 1 MHz                              VBW: 1 MHz                       Detector:         Max peak

5.1.3    Test result

PK results
                                            Reading    Correction Corrected
                                 Frequency                                            Limit PK        Delta
                   Channel                  level PK     factor      level PK
                                   (MHz)                                              dB(µV/m)        (dB)
                                             (dBµV)       (dB)      dB(µV/m)
                    0           2480          109.3      -14.3         94.9             114.0         -19.1
                    1           2405          107.5      -14.9         92.7             114.0         -21.3
                    7           2450          108.5      -14.7         93.8             114.0         -20.2
Note: The correction factor includes cable loss and antenna factor.

AV results
                                                       Duty cycle
                                 Frequency         Level PK         Level AV          Limit AV        Delta
                   Channel                             correction
                                   (MHz)            (dBµV)          dB(µV/m)          dB(µV/m)        (dB)
                                                          (dB)
                    0           2480          94.9       -29.3        65.6               94.0         -28.4
                    1           2405          92.7       -29.3        63.4               94.0         -30.6
                    7           2450          93.8       -29.3        64.5               94.0         -29.5
Note: The correction factor includes cable loss and antenna factor.


Average-Limit according to FCC Part 15C, Section 15.249 and RSS-210 A2.9:

                 Frequency                                        Field strength of fundamental
                   (MHz)                                      (mV/m)                         dB(µV/m)
                   902 - 928                                    50                                    94
                2400 - 2483.5                                   50                                    94
                  5725-5875                                     50                                    94
                24000 - 24250                                  250                                   108


The requirements are FULFILLED.


Remarks:            Duty cycle correction factor is calculated under subclause 5.4 of this report.




CSA Group Bayern GmbH                                                          File No. T39567-00-02JP, page 11 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                           Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                  IC: 20465-RR01

 5.2     Out-of-band emission, radiated
For test instruments and accessories used see section 6 Part SER1, SER 2, SER 3.
5.2.1    Description of the test location

Test location:                OATS 1
Test location:                Anechoic chamber 1

Test distance:                3m

5.2.2    Photo documentation of the test set-up

Test setup 30 MHz – 1000 MHz:




Test setup >1 GHz:




CSA Group Bayern GmbH                                                   File No. T39567-00-02JP, page 12 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                             Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                           IC: 20465-RR01


5.2.3    Applicable standard

According to FCC Part 15C, Section 15.209 and RSS-Gen 8.9:

5.2.4    Description of Measurement

The radiated emissions from the EUT are measured in the frequency range of 9 kHz to 1000 MHz using a tuned
receiver and appropriate broadband linearly polarized antennas. The setup of the EUT and the measurement
procedure is in accordance to ANSI C63.10, Item 6.3. In the frequency range above 1 GHz a spectrum analyser is
used with appropriate linear polarized antennas. If the emission level in peak mode complies with the average limit
testing is stopped and peak values will be reported, otherwise, the emission is measured in average mode again and
reported. The EUT is measured in TX continuous mode unmodulated under normal conditions.

Instrument settings:
9 kHz – 150 kHz                       RBW:             200 Hz
150 kHz - 30 MHz                      RBW:             9 kHz
30 MHz – 1000 MHz:                    RBW:             120 kHz
1000 MHz – 25 GHz                     RBW:             1 MHz

                 5.2.1 Test result f < 30 MHz
Note: In the frequency range 9 kHz to 30 MHz no emission could be detected. The frequencies mention the noise
       level. The measurement results from distance 3 m are extrapolated (D factor) to the specified distance.

                      Frequency      Reading PK        D factor     Level PK     Limit AV      Delta
                        (MHz)          dB(µV)         dB(µV/m)      dB(µV/m)     dB(µV/m)      (dB)
                        0.047           52.0            -80.0         -28.0        34.2        -62.2
                         1.5            51.0            -40.0          11.0        24.1        -13.1
                         18.2           39.0            -40.0          -1.0        29.5        -30.5


5.2.2    Test result f < 1 GHz

Channel 0
                          Frequency        Reading     Correction    Corrected      Limit     Delta
                                           level QP      factor      level QP
                            (MHz)           (dBµV)      (dB/m)       dB(µV/m)     dB(µV/m)     (dB)
                            127.26           11.5         13.6         25.1         43.5      -18.4
                            137.51            6.2         14.3         20.5         43.5      -23.0
                            211.36           16.5         12.3         28.8         43.5      -14.7
                            332.81            8.7         17.7         26.4         46.0      -19.6

Channel 1
                          Frequency        Reading     Correction    Corrected      Limit     Delta
                                           level QP      factor      level QP
                            (MHz)           (dBµV)      (dB/m)       dB(µV/m)     dB(µV/m)     (dB)
                            127.26           11.7         13.6         25.3         43.5      -18.2
                            137.51            6.0         14.3         20.3         43.5      -23.2
                            211.36           16.5         12.3         28.8         43.5      -14.7
                            332.81            8.9         17.7         26.6         46.0      -19.4




CSA Group Bayern GmbH                                                             File No. T39567-00-02JP, page 13 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                       Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                   IC: 20465-RR01


Channel 7
                          Frequency  Reading     Correction Corrected       Limit      Delta
                                     level QP       factor    level QP
                        (MHz)         (dBµV)       (dB/m)     dB(µV/m)    dB(µV/m)      (dB)
                        127.26         11.0          13.6        24.6       43.5       -18.9
                        137.51          6.2          14.3        20.5       43.5       -23.0
                        211.36         16.4          12.3        28.7       43.5       -14.8
                        332.81          8.7          17.7        26.4       46.0       -19.6
Note: The correction factor includes cable loss and antenna factor.

5.2.3 Test result f > 1 GHz
Channel 0
PK results
                                     Reading     Correction Corrected
                          Frequency                                         Limit PK     Delta
                                     level PK      factor      level PK
                            (MHz)                                          dB(µV/m)       (dB)
                                      (dBµV)         (dB)     dB(µV/m)
                       1438.00         58.7         -20.6        38.0         74.0       -36.0
                       4960.00         53.1           3.2        56.3         74.0       -17.7
                       7440.00         49.2           7.1        56.2         74.0       -17.8
Note: The correction factor includes cable loss and antenna factor.
Note: For frequencies were the PK value is below the average limit, no duty cycle correction was performed

AV results
                                                 Duty cycle
                          Frequency        Level PK           Level AV      Limit AV     Delta
                                                  correction
                            (MHz)           (dBµV)            dB(µV/m)     dB(µV/m)       (dB)
                                                     (dB)
                       4960.00         56.3         -29.3        27.0         54.0       -27.0
                       7440.00         56.2         -29.3        26.9         54.0       -27.1
Note: The correction factor includes cable loss and antenna factor.
Note: For frequencies were the PK value is below the average limit, no duty cycle correction was performed

Channel 1
PK results
                                     Reading     Correction Corrected
                          Frequency                                         Limit PK     Delta
                                     level PK      factor      level PK
                            (MHz)                                          dB(µV/m)       (dB)
                                      (dBµV)         (dB)     dB(µV/m)
                       1330.00         58.1         -19.8        38.3          74        -35.7
                       1848.00         59.8         -17.2        42.6          74        -31.4
                       4810.00         54.7           2.7        57.4          74        -16.6
                       7215.00         46.7           7.2        53.9          74        -20.1
Note: The correction factor includes cable loss and antenna factor.
Note: For frequencies were the PK value is below the average limit, no duty cycle correction was performed

AV results
                                                 Duty cycle
                          Frequency        Level PK           Level AV      Limit AV     Delta
                                                  correction
                            (MHz)           (dBµV)            dB(µV/m)     dB(µV/m)       (dB)
                                                     (dB)
                       4810.00         57.4         -29.3        28.1          54        -25.9
Note: The correction factor includes cable loss and antenna factor.
Note: For frequencies were the PK value is below the average limit, no duty cycle correction was performed




CSA Group Bayern GmbH                                                     File No. T39567-00-02JP, page 14 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                         IC: 20465-RR01


Channel 7
PK results
                                     Reading     Correction Corrected
                          Frequency                                         Limit PK     Delta
                                     level PK      factor      level PK
                            (MHz)                                          dB(µV/m)       (dB)
                                      (dBµV)         (dB)     dB(µV/m)
                       1327.60         57.3         -19.8        37.5          74        -36.5
                       1444.00         58.5         -20.7        37.8          74        -36.2
                       1864.00         57.7         -17.0        40.7          74        -33.3
                       4900.00         54.9           2.9        57.7          74        -16.3
                       7350.00         47.0           7.0        54.0          74        -20.0
Note: The correction factor includes cable loss and antenna factor.
Note: For frequencies were the PK value is below the average limit no duty cycle correction was performed

AV results
                                                 Duty cycle
                          Frequency        Level PK           Level AV      Limit AV     Delta
                                                  correction
                            (MHz)           (dBµV)            dB(µV/m)     dB(µV/m)       (dB)
                                                     (dB)
                       4900.00         57.7         -29.3        28.4          54        -25.6
                       7350.00         54.0         -29.3        24.7          54        -29.3
Note: The correction factor includes cable loss and antenna factor.
Note: For frequencies were the PK value is below the average limit, no duty cycle correction was performed


Limit according to FCC Part 15C, Section 15.209 and RSS-Gen 8.9:

                               Frequency                                    Limit                Measurement
                                 (MHz)                                     (µV/m)                distance (m)
                               0.009 - -0.49                            2400/f(kHz)                  300
                               0.49 – 1.705                             24000/f(kHz)                  30
                               1.705 – 30.0                                  30                       30
                                   30 - 88                                  100                        3
                                  88 - 216                                  150                        3
                                 216 - 960                                  200                        3
                                Above 960                                   500                        3


The requirements are FULFILLED.


Remarks:            The measurement was performed up to the 10th harmonic (25000 MHz).

                    Duty cycle correction factor is calculated under subclause 5.4 of this report.

                    The limit according to FCC subpart 15.209 and RSS-Gen 8.9 are met.




CSA Group Bayern GmbH                                                          File No. T39567-00-02JP, page 15 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                     Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                   IC: 20465-RR01

 5.3     EBW
For test instruments and accessories used see section 6 Part SER 3.
5.3.1    Description of the test location

Test location:                Anechoic chamber 1

5.3.2    Photo documentation of the test set-up




                   5.3.3    Applicable standard

According to FCC Part 15, Section 15.215 and RSS-Gen 6.6:

5.3.4    Description of Measurement

Spectrum analyser settings:
See attached plots




CSA Group Bayern GmbH                                                 File No. T39567-00-02JP, page 16 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                           Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                       IC: 20465-RR01


5.3.5    Test result

                                                   20 dB Bandwidth                    99% Bandwidth
            Channel
                                                        (MHz)                            (MHz)
         0 (2480 MHz)                                   2.634                             2.518
         1 (2405 MHz)                                   2.634                             2.373
         7 (2450 MHz)                                   2.605                             2.460


The requirements are FULFILLED.


Remarks:            none




CSA Group Bayern GmbH                                                     File No. T39567-00-02JP, page 17 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                               Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                IC: 20465-RR01


5.3.6    Test protocols

20dB Bandwidth, Channel 0




                            Date: 26.OCT.2015   14:49:24

20dB Bandwidth, Channel 1




                               Date: 26.OCT.2015   14:44:20




CSA Group Bayern GmbH                                              File No. T39567-00-02JP, page 18 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                        Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                IC: 20465-RR01


20dB Bandwidth, Channel 7




                               Date: 26.OCT.2015   14:51:51


99% Bandwidth, Channel 0




                               Date: 26.OCT.2015   14:54:34




CSA Group Bayern GmbH                                              File No. T39567-00-02JP, page 19 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                        Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                IC: 20465-RR01


99% Bandwidth, Channel 1




                               Date: 26.OCT.2015   14:56:14


99% Bandwidth, Channel 7




                               Date: 26.OCT.2015   14:53:27




CSA Group Bayern GmbH                                              File No. T39567-00-02JP, page 20 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                        Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                     IC: 20465-RR01

 5.4     Correction for pulse operation (duty cycle)
For test instruments and accessories used see section 6 Part DC.
5.4.1    Description of the test location

Test location:                Anechoic chamber 1

5.4.2    Photo documentation of the test set-up




                   5.4.3    Applicable standard

According to FCC Part 15A, Section 15.35 and RSS-Gen 6.10:
When the radiated emission limits are expressed in terms of average value and pulsed operation is employed, the
measurement field strength shall be determined by averaging over one complete puls train, including blanking
intervals, as long as the pulse train does not exceed 0.1s. In cases where the puls train exceeds 0.1s, the measured
field strength shall be determined from the average absolute voltage during a 0.1s interval during which the field
strength is at its maximum. The exact method of calculating the average field strength shall be submitted.




CSA Group Bayern GmbH                                                     File No. T39567-00-02JP, page 21 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                 Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                       IC: 20465-RR01


5.4.4     Description of Measurement

The duty cycle correction factor (dB) is calculated applying the following formula:

                                           δ(dB) = 20 log ((t1 + t2 +… + tn) / T)
δ(dB)    duty cycle correction factor expressed in dB
t1       duration of pulse 1 in the defined time period T
tn       duration of pulse n in the defined time period T
T        period of one complete puls train or 100ms if the complete puls train is longer 100ms

5.4.5    Test result

               t1                        t2                 t3                    t4                  T
              [ms]                      [ms]               [ms]                  [ms]                [ms]
              3.40                       --                 --                    --                 100


RESULT δ(dB) = -29.3


Remarks:             Maximum possible duty cycle used for calculation.




CSA Group Bayern GmbH                                                        File No. T39567-00-02JP, page 22 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                  Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                                                     IC: 20465-RR01

5.4.6    Test protocol

                        Determination of T = 203.92ms (due to 100ms maximum 100ms are used)
                                                                                    RBW 1 MHz    Delta 2 [T1 ]
                                                                                    VBW 3 MHz               -0.01 dB
                                         Ref   100 dBµV        * Att   10 dB        SWT 500 ms         203.920000 ms

                                         100                                                     Marker 1 [T1 ]
                                                                                                           73.89 dBµV
                                                                                                        42.200000 ms    A
                                         90
                                                                                                                        SGL
                                 1 AP
                                 CLRWR
                                         80
                                               1                                2


                                         70



                                         60



                                         50

                                                                                                                        3DB
                                         40



                                         30



                                         20



                                         10


                                         0

                                         Center 2.44954 GHz                    50 ms/




                                Date: 15.JUL.2015         12:07:33

                                                              Determination of t1 = 3.40ms
                                                                                    RBW 1 MHz    Delta 2 [T1 ]
                                                                                    VBW 3 MHz              -21.49 dB
                                         Ref   100 dBµV        * Att   10 dB        SWT 50 ms            3.400000 ms

                                         100                                                     Marker 1 [T1 ]
                                                                                                           73.88 dBµV
                                                                                                         7.900000 ms    A
                                         90
                                                                                                                        SGL
                                 1 AP
                                 CLRWR
                                         80
                                                    1


                                         70



                                         60

                                                          2

                                         50

                                                                                                                        3DB

                                         40



                                         30



                                         20



                                         10


                                         0

                                         Center 2.44954 GHz                    5 ms/




                                Date: 15.JUL.2015         12:08:48




CSA Group Bayern GmbH                                                                                             File No. T39567-00-02JP, page 23 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                                                       Rev. No. 4.0, 2015-04-17


                              FCC ID: SZO-RR01                            IC: 20465-RR01

6 USED TEST EQUIPMENT AND ACCESSORIES
All test instruments used are calibrated and verified regularly. The calibration history is available on request.

   Test ID       Model Type                        Equipment No.      Next Calib.    Last Calib.   Next Verif.    Last Verif.
   CPR 3          FSP 40                            02-02/11-11-001   02/10/2015      02/10/2014
                  AFS4-01000400-10-10P-4            02-02/17-13-002
                  3117                              02-02/24-05-009   12/05/2016      12/05/2015
                  Sucoflex N-2000-SMA               02-02/50-05-075
                  SF104/11N/11N/1500MM              02-02/50-13-015

   DC             FSP 40                            02-02/11-11-001   02/10/2015      02/10/2014
                  AFS4-01000400-10-10P-4            02-02/17-13-002
                  3117                              02-02/24-05-009   12/05/2016      12/05/2015
                  Sucoflex N-2000-SMA               02-02/50-05-075
                  SF104/11N/11N/1500MM              02-02/50-13-015

   SER 1          FMZB 1516                         01-02/24-01-018                                 19/01/2016      19/01/2015
                  ESR 7                             02-02/03-13-001   29/05/2016      29/05/2015
                  KK-EF393-21N-16                   02-02/50-05-033
                  NW-2000-NB                        02-02/50-05-113
                  KK-SD_7/8-2X21N-33,0M             02-02/50-15-028

   SER 2          ESVS 30                           02-02/03-05-003   09/07/2016      09/07/2015
                  VULB 9168                         02-02/24-05-005   17/04/2016      17/04/2015    29/02/2016      31/08/2015
                  NW-2000-NB                        02-02/50-05-113
                  KK-EF393/U-16N-21N20 m            02-02/50-12-018
                  KK-SD_7/8-2X21N-33,0M             02-02/50-15-028

   SER 3          FSP 40                            02-02/11-11-001   02/10/2015      02/10/2014
                  JS4-18004000-30-5A                02-02/17-05-017
                  AFS5-12001800-18-10P-6            02-02/17-06-002
                  AFS4-01000400-10-10P-4            02-02/17-13-002
                  AMF-4F-04001200-15-10P            02-02/17-13-003
                  3117                              02-02/24-05-009   12/05/2016      12/05/2015
                  BBHA 9170                         02-02/24-05-014   02/06/2018      02/06/2015    02/06/2016      02/06/2015
                  Sucoflex N-2000-SMA               02-02/50-05-075
                  KMS102-0.2 m                      02-02/50-11-020
                  SF104/11N/11N/1500MM              02-02/50-13-015




CSA Group Bayern GmbH                                                               File No. T39567-00-02JP, page 24 of 24
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                          Rev. No. 4.0, 2015-04-17



Document Created: 2015-11-11 14:54:26
Document Modified: 2015-11-11 14:54:26

© 2024 FCC.report