03 FCC Test Report_DTS

FCC ID: SQK-7BLZ20

Test Report

Download: PDF
FCCID_4148601

                                                                                Test report No.        : 12634949H-A-R2
                                                                                Page                   : 1 of 36
                                                                                Issued date            : January 28, 2019
                                                                                FCC ID                 : SQK-7BLZ20




                             RADIO TEST REPORT
                               Test Report No. : 12634949H-A-R2
        Applicant                            :     Fujitsu Component Limited

        Type of Equipment                    :     Bluetooth Low Energy Module

        Model No.                            :     FWM7BLZ20B

        FCC ID                               :     SQK-7BLZ20

        Test regulation                      :     FCC Part 15 Subpart C: 2018
                                                   For Permissive Change

        Test Result                          :     Complied (Refer to Section 3.2)
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report covers Radio technical requirements. It does not cover administrative issues such
                as Manual or non-Radio test related Requirements. (if applicable)
           6.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           7.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           8.   The information provided from the customer for this report is identified in SECTION 1.
           9.   This report is a revised version of 12634949H-A-R1. 12634949H-A-R1 is replaced with this report.

                         Date of test:               December 5, 2018 to January 23, 2019

                         Representative test
                         engineer:
                                                               Junki Nagatomi
                                                                  Engineer
                                                         Consumer Technology Division


                         Approved by:
                                                              Takayuki Shimada
                                                                   Leader
                                                         Consumer Technology Division

                                                          This laboratory is accredited by the NVLAP LAB CODE
                                                          200572-0, U.S.A. The tests reported herein have been
                                                          performed in accordance with its terms of accreditation.
                                                          *As for the range of Accreditation in NVLAP, you may
                                                          refer to the WEB address,
                                                          http://japan.ul.com/resources/emc_accredited/

      NVLAP LAB CODE: 200572-0

     The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
     There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                                            13-EM-F0429


                                                                      Test report No.    : 12634949H-A-R2
                                                                      Page               : 2 of 36
                                                                      Issued date        : January 28, 2019
                                                                      FCC ID             : SQK-7BLZ20




                                  REVISION HISTORY
                               Original Test Report No.: 12634949H-A

Revision     Test report No.        Date               Page       Contents
                                                       revised
-            12634949H-A            January 11, 2019   -          -
(Original)
1            12634949H-A-R1         January 24, 2019   P.1        Correction of note No.8.
1            12634949H-A-R1         January 24, 2019   P.4        SECTION 1: Addition of note.
1            12634949H-A-R1         January 24, 2019   P.4        SECTION 2.1: Addition of note for Receipt
                                                                  Date of Sample.
1            12634949H-A-R1         January 24, 2019   P.8        Correction of Low power setting:
                                                                  from -16 dBm to -20 dBm
1            12634949H-A-R1         January 24, 2019   P.19, 20   Correction of test data (Lowest power setting)
2            12634949H-A-R2         January 28, 2019   P.1        Addition of sentence “For Permissive Change”
2            12634949H-A-R2         January 28, 2019   P.4        Addition of “Contents of the change from
                                                                  original model”.
2            12634949H-A-R2         January 28, 2019   P.15       Correction of test chart
2            12634949H-A-R2         January 28, 2019   P.19, 20   Correction of Result of Lowest power setting:
                                                                  from two places of decimals to three places of
                                                                  decimals




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                               Test report No.            : 12634949H-A-R2
                                                                                               Page                       : 3 of 36
                                                                                               Issued date                : January 28, 2019
                                                                                               FCC ID                     : SQK-7BLZ20


CONTENTS                                                                                                                                PAGE

SECTION 1: Customer information.......................................................................................................4
SECTION 2: Equipment under test (E.U.T.) .........................................................................................4
SECTION 3: Test specification, procedures & results..........................................................................5
    a) Refer to Appendix 1 (Data of Conducted Emission) ......................................................................5
SECTION 4: Operation of E.U.T. during testing ..................................................................................8
SECTION 5: Conducted Emission ........................................................................................................10
SECTION 6: Radiated Spurious Emission ..........................................................................................11
SECTION 7: Antenna Terminal Conducted Tests ..............................................................................13
APPENDIX 1: Test data ........................................................................................................................14
    Conducted Emission ......................................................................................................................... 14
    6 dB Bandwidth and 99 % Occupied Bandwidth.............................................................................. 16
    Maximum Peak Output Power .......................................................................................................... 19
    Average Output Power ...................................................................................................................... 20
    Radiated Spurious Emission ............................................................................................................. 22
    Conducted Spurious Emission .......................................................................................................... 28
    Power Density ................................................................................................................................... 31
APPENDIX 2: Test instruments ...........................................................................................................33
APPENDIX 3: Photographs of test setup .............................................................................................34
    Conducted Emission ......................................................................................................................... 34
    Radiated Spurious Emission ............................................................................................................. 35
    Worst Case Position .......................................................................................................................... 36




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.      : 12634949H-A-R2
                                                                        Page                 : 4 of 36
                                                                        Issued date          : January 28, 2019
                                                                        FCC ID               : SQK-7BLZ20


SECTION 1:         Customer information
Company Name                         :       Fujitsu Component Limited
Address                              :       1174, Oaza Suzaka, Suzaka-shi, Nagano, 382-0076, Japan
Telephone Number                     :       +81-26 248-7993
Facsimile Number                     :       +81-26-248-2840
Contact Person                       :       Masafumi Chiba

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No. on the cover and other relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the information in SECTION 2 and 4.



SECTION 2:         Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

Type of Equipment                    :       Bluetooth Low Energy Module
Model No.                            :       FWM7BLZ20B
Serial No.                           :       Refer to Section 4, Clause 4.2
Rating                               :       DC 3.0 V (DC 1.7 to 3.6 V)
Receipt Date of Sample               :       December 3, 2018
(Information from test lab.)
Country of Mass-production           :       Japan
Condition of EUT                     :       Production prototype
                                             (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                  :       No Modification by the test lab


2.2       Product Description

Model: FWM7BLZ20B (referred to as the EUT in this report) is a Bluetooth Low Energy Module.

Radio Specification

Radio Type                               :   Transceiver
Frequency of Operation                   :   2402 MHz - 2480 MHz
Modulation                               :   GFSK
Antenna type                             :   Mono-pole antenna
Antenna Gain                             :   -0.4 dBi
Clock frequency (Maximum)                :   32 MHz
Operating temperature                    :   -40 deg. C to +85 deg. C

<Contents of the change from original model>
Test Report Number of original model is 11451821H-A-R1 (issued by UL Japan, Inc.).
Specification was changed from the original model as follows:
RF bandwidth of 2 MHz was added.
The other radio specification is identical to the original.
Therefore, tests were only performed on 2M-PHY mode in this report.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                      Test report No.      : 12634949H-A-R2
                                                                                      Page                 : 5 of 36
                                                                                      Issued date          : January 28, 2019
                                                                                      FCC ID               : SQK-7BLZ20


 SECTION 3:            Test specification, procedures & results

 3.1        Test Specification

 Test Specification                       :   FCC Part 15 Subpart C

 Title                                    :   FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                              Section 15.207 Conducted limits
                                              Section 15.247 Operation within the bands 902-928 MHz,
                                              2400-2483.5 MHz, and 5725-5850 MHz

 * Also the EUT complies with FCC Part 15 Subpart B.

 3.2        Procedures and results

Item           Test Procedure                  Specification        Test Method        Worst margin           Results     Remarks
               FCC: ANSI C63.10-2013           FCC: Section                            QP
               6. Standard test methods        15.207                                  6.5 dB, 0.19432 MHz, N
Conducted                                                                                                     Complied
                                                                    -                  AV                                 -
Emission
               IC: RSS-Gen 8.8                 IC: RSS-Gen 8.8                         17.0 dB, 0.19432 MHz, a)
                                                                                       N
                FCC: KDB 558074 D01 15.247     FCC: Section
                                                                                                             Complied
6dB Bandwidth Meas Guidance v05                15.247(a)(2)         Conducted                                             -
                IC: -                          IC: RSS-247 5.2(a)
                                                                                                             b)
                FCC: KDB 558074 D01 15.247     FCC: Section
Maximum Peak                                                                                                 Complied
                Meas Guidance v05              15.247(b)(3)         Conducted          See data.                          -
Output Power                                                                                                 c)
                IC: RSS-Gen 6.12               IC: RSS-247 5.4(d)
                FCC: KDB 558074 D01 15.247     FCC: Section
                                                                                                             Complied
Power Density Meas Guidance v05                15.247(e)            Conducted                                             -
                IC: -                          IC: RSS-247 5.2(b)
                                                                                                             d)
                FCC: KDB 558074 D01 15.247     FCC:
Spurious                                                            Conducted
                Meas Guidance v05              Section15.247(d)
Emission                                                            (below 30 MHz)/    2.1 dB                 Complied#
                                               IC: RSS-247 5.5                                                            *1)
Restricted Band                                                     Radiated           7320.00 MHz, AV, Hori. e), f)
                IC: RSS-Gen 6.13               RSS-Gen 8.9
Edges                                                               (above 30 MHz)
                                               RSS-Gen 8.10
Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) Radiated test was selected over 30 MHz based on section 15.247(d) and KDB 558074 D01 15.247 Meas Guidance v05 8.5 and 8.6.

a) Refer to Appendix 1 (Data of Conducted Emission)
b) Refer to Appendix 1 (Data of 6 dB Bandwidth and 99 % Occupied Bandwidth)
c) Refer to Appendix 1 (Data of Maximum Peak Output Power)
d) Refer to Appendix 1 (Data of Power Density)
e) Refer to Appendix 1 (Data of Radiated Spurious Emission)
f) Refer to Appendix 1 (Data of Conducted Spurious Emission)
Symbols:
  Complied             The data of this test item has enough margin, more than the measurement uncertainty.
  Complied#            The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.
 * In case any questions arise about test procedure, ANSI C63.10: 2013 is also referred.

 FCC Part 15.31 (e)
 This EUT provides stable voltage constantly to RF Module regardless of input voltage. Therefore, this EUT complies
 with the requirement.

 FCC Part 15.203/212 Antenna requirement
 It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
 equipment complies with the antenna requirement of Section 15.203.




 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone : +81 596 24 8999
 Facsimile : +81 596 24 8124


                                                                                   Test report No.          : 12634949H-A-R2
                                                                                   Page                     : 6 of 36
                                                                                   Issued date              : January 28, 2019
                                                                                   FCC ID                   : SQK-7BLZ20


 3.3        Addition to standard

Item                         Test Procedure      Specification    Test Method Worst margin             Results    Remarks
99% Occupied                 IC: RSS-Gen 6.6     IC: -            Conducted   N/A                      Complied   -
Bandwidth                                                                                              a)
a) Refer to Appendix 1 (Data of 6 dB Bandwidth and 99 % Occupied Bandwidth)
Symbols:
 Complied             The data of this test item has enough margin, more than the measurement uncertainty.
 Complied#            The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.
 Other than above, no addition, exclusion nor deviation has been made from the standard.


 3.4        Uncertainty

 EMI

 There is no applicable rule of uncertainty in this applied standard. Therefore, the following results are derived depending on whether or
 not laboratory uncertainty is applied.

 The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k=2.
 Ise EM C Lab.

 Antenna Terminal test
       Test Item                                                                   Uncertainty (+/-)
 6 dB Bandwidth / 99 % Occupied Bandwidth                                              0.96 %
 M aximum Peak Output Power / Average Output Power                                     1.3 dB
 Burst Rate                                                                            0.10 %
 Power Density                                                                         2.7 dB
 Conducted Spurious Emission                                                           2.7 dB
 Radiated emission
    Measurement
                                         Frequency range                           Uncertainty (+/-)
       distance
          3m                             9 kHz to 30 M Hz                               3.3 dB
         10 m                                                                           3.2 dB

          3m                  30 M Hz to 200 M Hz (Horizontal)                          4.8 dB
                                                  (Vertical)                            5.0 dB
                            200 M Hz to 1000 M Hz (Horizontal)                          5.2 dB
                                                  (Vertical)                            6.3 dB
          10 m                30 M Hz to 200 M Hz (Horizontal)                          4.8 dB
                                                  (Vertical)                            4.9 dB
                            200 M Hz to 1000 M Hz (Horizontal)                          5.0 dB
                                                  (Vertical)                            5.0 dB

          3m                             1 GHz to 6 GHz                                 5.0 dB
                                        6 GHz to 18 GHz                                 5.3 dB
          1m                           10 GHz to 26.5 GHz                               5.8 dB
                                       26.5 GHz to 40 GHz                               5.8 dB
          10 m                          1 GHz to 18 GHz                                 5.2 dB




 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone : +81 596 24 8999
 Facsimile : +81 596 24 8124


                                                                                    Test report No.         : 12634949H-A-R2
                                                                                    Page                    : 7 of 36
                                                                                    Issued date             : January 28, 2019
                                                                                    FCC ID                  : SQK-7BLZ20


3.5         Test Location

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                  Maximum
                     IC Registration Width x Depth x      Size of reference ground plane (m)
Test site                                                                                    Other rooms          measuremen
                     Number          Height (m)           / horizontal conducting plane
                                                                                                                  t distance
No.1 semi-anechoic                                                                            No.1 Power
                     2973C-1         19.2 x 11.2 x 7.7    7.0 x 6.0                                               10 m
chamber                                                                                       source room
No.2 semi-anechoic
                     2973C-2         7.5 x 5.8 x 5.2      4.0 x 4.0                           -                   3m
chamber
No.3 semi-anechoic                                                                            No.3 Preparation
                     2973C-3         12.0 x 8.5 x 5.9     6.8 x 5.75                                              3m
chamber                                                                                       room
No.3 shielded room   -               4.0 x 6.0 x 2.7      N/A                                 -                   -
No.4 semi-anechoic                                                                            No.4 Preparation
                     2973C-4         12.0 x 8.5 x 5.9     6.8 x 5.75                                              3m
chamber                                                                                       room
No.4 shielded room   -               4.0 x 6.0 x 2.7      N/A                                 -                   -
No.5 semi-anechoic
                     -               6.0 x 6.0 x 3.9      6.0 x 6.0                           -                   -
chamber
No.6 shielded room   -               4.0 x 4.5 x 2.7      4.0 x 4.5                           -                   -
No.6 measurement
                     -               4.75 x 5.4 x 3.0     4.75 x 4.15                         -                   -
room
No.7 shielded room   -               4.7 x 7.5 x 2.7      4.7 x 7.5                           -                   -
No.8 measurement
                     -               3.1 x 5.0 x 2.7      3.1 x 5.0                           -                   -
room
No.9 measurement
                     -               8.8 x 4.6 x 2.8      2.4 x 2.4                           -                   -
room
No.11 measurement
                     -               6.2 x 4.7 x 3.0      4.8 x 4.6                           -                   -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0m for No.1, No.2, No.3, and No.4
semi-anechoic chambers and No.3 and No.4 shielded rooms.




3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.    : 12634949H-A-R2
                                                                        Page               : 8 of 36
                                                                        Issued date        : January 28, 2019
                                                                        FCC ID             : SQK-7BLZ20


SECTION 4:         Operation of E.U.T. during testing

4.1        Operating Mode(s)
Bluetooth (BT) Low Energy (LE):
Mode                                                     Remarks*
Bluetooth (BT) Low Energy (LE) 2M-PHY                    Maximum Packet Size, PRBS9
*Power of the EUT was set by the software as follows;
Power settings:       High power : 4 dBm
                      Low Power : -20 dBm
Software:             BLZ20B_DTM_v2.0.0
*This setting of software is the worst case.
Any conditions under the normal use do not exceed the condition of setting.
In addition, end users cannot change the settings of the output power of the product.

*The details of Operating mode(s)
Test Item                               Operating Mode                       Tested frequency
Conducted Emission                      Tx BLE 2M-PHY                        2402 MHz
6dB Bandwidth                                                                2440 MHz
Maximum Peak Output Power                                                    2480 MHz
Power Density
99% Occupied Bandwidth
Spurious Emission(Radiated /
Conducted)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                              Test report No.       : 12634949H-A-R2
                                                                              Page                  : 9 of 36
                                                                              Issued date           : January 28, 2019
                                                                              FCC ID                : SQK-7BLZ20


Configuration and peripherals

                                                         B     1    C
                                                 A
                                                                        2
                                                                    D

                                                                        3
                                                                    E
                                                                        4
                                      : Standard Ferrite Core
                                                             AC 120 V / 60 Hz

* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.

Description of EUT and Support Equipment
 No.           Item          Model number                     Serial number                Manufacturer             Remarks
 A     Bluetooth Low       FWM7BLZ20B                    1                          Fujitsu Component               EUT
       Energy Module                                                                Limited
 B     Jig                 -                             -                          Fujitsu Component               -
                                                                                    Limited
 C     Jig                     -                         -                          Fujitsu Component               -
                                                                                    Limited
 D     Laptop PC               CF-N8HWCDPS               0BKSA07449                 Panasonic                       -
 E     AC Adapter              CF-AA6372B                6372BM409X17298B           Panasonic                       -

List of cables used
 No.            Name                    Length (m)                                  Shield                           Remarks
                                                                     Cable                      Connector
 1     Signal Cable                0.2                             Unshielded                   Unshielded          -
 2     USB Cable                   2.0                              Shielded                     Shielded           -
 3     DC Cable                    1.1                             Unshielded                   Unshielded          -
 4     AC Cable                    1.0 for CE*                     Unshielded                   Unshielded          -
                                   0.9 for other tests

*CE: Conducted emission




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.      : 12634949H-A-R2
                                                                         Page                 : 10 of 36
                                                                         Issued date          : January 28, 2019
                                                                         FCC ID               : SQK-7BLZ20


SECTION 5: Conducted Emission

Test Procedure and conditions

EUT was placed on a urethane platform of nominal size, 1.0 m by 1.5 m, raised 0.8 m above the conducting ground
plane.
The rear of tabletop was located 40 cm to the vertical conducting plane. The rear of EUT, including peripherals
aligned and flushed with rear of tabletop. All other surfaces of tabletop were at least 80cm from any other grounded
conducting surface. EUT was located 80 cm from a Line Impedance Stabilization Network (LISN) / Artificial mains
Network (AMN) and excess AC cable was bundled in center.

For the tests on EUT with other peripherals (as a whole system)
I/O cables that were connected to the peripherals were bundled in center. They were folded back and forth forming a
bundle 30 cm to 40 cm long and were hanged at a 40 cm height to the ground plane. All unused 50ohm connectors of
the LISN (AMN) were resistivity terminated in 50 ohm when not connected to the measuring equipment.

The AC Mains Terminal Continuous disturbance Voltage has been measured with the EUT in a Semi Anechoic
Chamber.
The EUT was connected to a LISN (AMN).
An overview sweep with peak detection has been performed.

The test results and limit are rounded off to one decimal place, so some differences might be observed.

Detector                       : QP and CISPR AV
Measurement range              : 0.15 MHz - 30 MHz
Test data                      : APPENDIX
Test result                    : Pass


Figure 1: Test Setup




                                               EUT



                             Attenuator
 Test
 receiver                         LISN

                                                 Ground plane




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.      : 12634949H-A-R2
                                                                         Page                 : 11 of 36
                                                                         Issued date          : January 28, 2019
                                                                         FCC ID               : SQK-7BLZ20


SECTION 6: Radiated Spurious Emission
Test Procedure

It was measured based on "8.5 and 8.6 of KDB 558074 D01 15.247 Meas Guidance v05".

[For below 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground
plane. The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 0.5 m, raised 1.5 m above the conducting ground
plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined
on a ground plane.

The height of the measuring antenna varied between 1 and 4 m and EUT was rotated a full revolution in order to
obtain the maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization with the Test Receiver, or the
Spectrum Analyzer.
The measurements were made with the following detector function of the test receiver and the Spectrum analyzer (in
linear mode).
The test was made with the detector (RBW/VBW) in the following table.
When using Spectrum analyzer, the test was made with adjusting span to zero by using peak hold.

Test Antennas are used as below;
   Frequency          30 MHz to 200 MHz 200 MHz to 1 GHz              Above 1 GHz
   Antenna Type       Biconical         Logperiodic                   Horn


In any 100 kHz bandwidth outside the restricted band in which the spread spectrum intentional radiator is operating,
the radio frequency power that is produced by the intentional radiator confirmed 20 dB below that in the 100 kHz
bandwidth within the band that contains the highest level of the desired power, based on a radiated measurement.

20 dBc was applied to the frequency over the limit of FCC 15.209 / Table 4 of RSS-Gen 8.9(IC) and outside the
restricted band of FCC15.205 / Table 6 of RSS-Gen 8.10 (IC).
   Frequency          Below 1 GHz       Above 1 GHz                                  20 dBc
   Instrument used    Test Receiver     Spectrum Analyzer                            Spectrum Analyzer
   Detector           QP                PK               AV *1)                      PK
   IF Bandwidth       BW 120 kHz        RBW: 1 MHz Average Power Method:             RBW: 100 kHz
                                        VBW: 3 MHz RBW: 1 MHz                        VBW: 300kHz
                                                         VBW: 3 MHz
                                                         Detector:
                                                         Power Averaging (RMS)
                                                         Trace: 100 traces
                                                         If duty cycle was less than
                                                         98%, a duty factor was
                                                         added to the results.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.        : 12634949H-A-R2
                                                                          Page                   : 12 of 36
                                                                          Issued date            : January 28, 2019
                                                                          FCC ID                 : SQK-7BLZ20


Figure 2: Test Setup

Below 1 GHz
                                                             Test Distance: 3 m




1 GHz - 10 GHz
                                                             Distance Factor: 20 x log (3.75 m / 3.0 m) = 1.94 dB
                                                             * Test Distance: (3 + Test Volume /2) - r = 3.75 m

                                                             Test Volume : 1.5 m
                                                             (Test Volume has been calibrated based on CISPR 16-1-4.)
                                                              r = 0.0 m

                                                             * The test was performed with r = 0.0 m since EUT is small
                                                             and it was the rather conservative condition.



10 GHz – 26.5 GHz
                                                             Distance Factor: 20 x log (1.0 m / 3.0 m) = -9.5 dB
                                                             *Test Distance: 1 m




- The carrier level and noise levels were confirmed at each position of X, Y and Z axes of EUT to see the position of
maximum noise, and the test was made at the position that has the maximum noise.

The test results and limit are rounded off to one decimal place, so some differences might be observed.

Measurement range              : 30 MHz - 26.5 GHz
Test data                      : APPENDIX
Test result                    : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                          Test report No.           : 12634949H-A-R2
                                                                                          Page                      : 13 of 36
                                                                                          Issued date               : January 28, 2019
                                                                                          FCC ID                    : SQK-7BLZ20


SECTION 7: Antenna Terminal Conducted Tests
Test Procedure

The tests were made with below setting connected to the antenna port.

Test                   Span                        RBW            VBW            Sweep      Detector           Trace           Instrument used
                                                                                 time
6dB Bandwidth          5 MHz                       100 kHz        300 kHz        Auto       Peak               Max Hold        Spectrum Analyzer
99% Occupied           Enough width to display     1 to 5 %       Three times    Auto       Peak               Max Hold        Spectrum Analyzer
Bandwidth *1)          emission skirts             of OBW           of RBW
Maximum Peak           -                           -              -              Auto       Peak/              -               Power Meter
Output Power                                                                                Average *2)                        (Sensor: 50 MHz BW)
Peak Power Density      1.5 times the              3 kHz           10 kHz        Auto       Peak              Max Hold         Spectrum Analyzer
                        6dB Bandwidth                                                                                          *3)
Conducted Spurious 9kHz to 150kHz                  200 Hz          620 Hz        Auto       Peak              Max Hold         Spectrum Analyzer
Emission *4)            150kHz to 30MHz            9.1 kHz         27 kHz
*1) Peak hold was applied as Worst-case measurement.
*2) Reference data
*3) Section 11.10.2 Method PKPSD (peak PSD) of "ANSI C63.10-2013".
*4) In the frequency range below 30MHz, RBW was narrowed to separate the noise contents.
     Then, wide-band noise near the limit was checked separately, however the noise was not detected as shown in the chart.
      (9 kHz - 150 kHz: RBW = 200 Hz, 150 kHz - 30 MHz: RBW = 9.1 kHz)



The test results and limit are rounded off to two decimals place, so some differences might be observed.

Test data                             : APPENDIX
Test result                           : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                            Test report No.                    : 12634949H-A-R2
                                                                                                            Page                               : 14 of 36
                                                                                                            Issued date                        : January 28, 2019
                                                                                                            FCC ID                             : SQK-7BLZ20


APPENDIX 1: Test data
                                                                  Conducted Emission

                       Report No.                                   12634949H
                       Test place                                   Ise EMC Lab. No.2 Semi Anechoic Chamber
                       Date                                         December 9, 2018 (Night)
                       Temperature / Humidity                       24 deg. C / 30 % RH
                       Engineer                                     Junki Nagatomi
                       Mode                                         Tx BT LE 2480 MHz

                LIMIT : FCC15.207 QP
                        FCC15.207 AV
                                                                                                                                           N      :QP   :AV
                    [dBuV]            << QP/AV DATA >>                                                                                     L      :QP   :AV
               90

               80

               70

               60

               50

               40

               30

               20

               10

                0
                .15M    .2M        .3M          .5M       .7M        1M                2M        3M           5M       7M        10M            20M      30M
                                                                                                                                               Frequency[Hz]



                                   Reading Level       Corr.          Results              Limit             Margin
                     Frequency
                                    QP       AV       Factor       QP         AV        QP       AV       QP        AV      Phase      Comment
                       [MHz]      [dBuV] [dBuV]        [dB]      [dBuV]    [dBuV]     [dBuV]   [dBuV]    [dB]     [dB]
                        0.15000      34.9     14.5        13.3      48.2       27.8      66.0     56.0     17.8      28.2    N
                        0.19432      44.1     23.6        13.2      57.3       36.8      63.8     53.8      6.5      17.0    N
                        0.25541      34.3     15.0        13.2      47.5       28.2      61.6     51.6     14.1      23.4    N
                        0.32124      28.4     13.0        13.3      41.7       26.3      59.7     49.7     18.0      23.4    N
                        0.41662      18.3      8.4        13.3      31.6       21.7      57.5     47.5     25.9      25.8    N
                       28.61620      13.7      8.3        15.1      28.8       23.4      60.0     50.0     31.2      26.6    N
                        0.15000      34.9     14.7        13.3      48.2       28.0      66.0     56.0     17.8      28.0    L
                        0.19350      43.7     22.7        13.2      56.9       35.9      63.9     53.9      7.0      18.0    L
                        0.25692      35.1     15.7        13.2      48.3       28.9      61.5     51.5     13.2      22.6    L
                        0.32304      28.2     12.8        13.3      41.5       26.1      59.6     49.6     18.1      23.5    L
                        0.42004      17.7      7.8        13.3      31.0       21.1      57.4     47.4     26.4      26.3    L
                       28.41840      13.9      8.5        15.1      29.0       23.6      60.0     50.0     31.0      26.4    L




      CHART: WITH FACTOR Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + CABLE + ATT)
      Except for the above table: adequate margin data below the limits.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.       : 12634949H-A-R2
                                                                        Page                  : 15 of 36
                                                                        Issued date           : January 28, 2019
                                                                        FCC ID                : SQK-7BLZ20


                                               Conducted Emission
                      Report No.                12634949H
                      Test place                Ise EMC Lab. No.2 Semi Anechoic Chamber
                      Date                      December 9, 2018 (Night)
                      Temperature / Humidity    24 deg. C / 30 % RH
                      Engineer                  Junki Nagatomi
                      Mode                      Tx BT LE

                                                      2402 MHz




                                                      2440 MHz




                                                      2480 MHz




     Y scale [dBuV]                                                       Chart     N     L




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.         : 12634949H-A-R2
                                                                        Page                    : 16 of 36
                                                                        Issued date             : January 28, 2019
                                                                        FCC ID                  : SQK-7BLZ20


                            6 dB Bandwidth and 99 % Occupied Bandwidth

                    Report No.                12634949H
                    Test place                Ise EMC Lab. No.8 Measurement Room
                    Date                      December 5, 2018
                    Temperature / Humidity    23 deg. C / 48 % RH
                    Engineer                  Junki Nagatomi
                    Mode                      Tx BT LE


                        Mode     Frequency    99% Occupied      6dB Bandwidth         Limit for
                                                Bandwidth                          6dB Bandwidth
                                   [MHz]          [kHz]            [MHz]               [MHz]
                        BLE            2402          2064.600              1.145            > 0.5000
                                       2440          2073.900              1.175            > 0.5000
                                       2480          2077.300              1.175            > 0.5000




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                 Test report No.   : 12634949H-A-R2
                                                                 Page              : 17 of 36
                                                                 Issued date       : January 28, 2019
                                                                 FCC ID            : SQK-7BLZ20


                                                6dB Bandwidth

                                                        BT LE
                                                      2402 MHz




                                                      2440 MHz




                                                      2480 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                 Test report No.   : 12634949H-A-R2
                                                                 Page              : 18 of 36
                                                                 Issued date       : January 28, 2019
                                                                 FCC ID            : SQK-7BLZ20


                                          99%Occupied Bandwidth

                                                        BT LE
                                                      2402 MHz




                                                      2440 MHz




                                                      2480 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                         Test report No.            : 12634949H-A-R2
                                                                                         Page                       : 19 of 36
                                                                                         Issued date                : January 28, 2019
                                                                                         FCC ID                     : SQK-7BLZ20


                                                  Maximum Peak Output Power

                         Report No.                       12634949H
                         Test place                       Ise EMC Lab. No.8 Measurement Room
                         Date                             December 5, 2018         January 23, 2019
                         Temperature / Humidity           23 deg. C / 48 % RH      25 deg. C / 40 % RH
                         Engineer                         Junki Nagatomi           Tomoki Matsui
                         Mode                             Tx BT LE

Highest Power setting (4dBm)                      Conducted Power                                  e.i.r.p. for RSS-247
 Freq. Reading Cable Atten.              Result            Limit    Margin Antenna               Result             Limit     Margin
                    Loss   Loss                                              Gain
[MHz] [dBm] [dB]           [dB]     [dBm]     [mW]    [dBm] [mW]     [dB]   [dBi]             [dBm]   [mW]    [dBm] [mW]     [dB]
 2402     -7.99    0.30   10.04      2.35      1.72   30.00 1000.00 27.65   -0.40              1.95    1.57   36.02 4000.00 34.07
 2440     -7.86    0.30   10.04      2.48      1.77   30.00 1000.00 27.52   -0.40              2.08    1.61   36.02 4000.00 33.94
 2480     -7.79    0.30   10.04      2.55      1.80   30.00 1000.00 27.45   -0.40              2.15    1.64   36.02 4000.00 33.87


Lowest Power setting (-20dBm)                     Conducted Power                                  e.i.r.p. for RSS-247
  Freq. Reading Cable Atten.             Result            Limit    Margin Antenna               Result             Limit     Margin
                   Loss    Loss                                              Gain
 [MHz] [dBm] [dB]          [dB]     [dBm]    [mW]     [dBm] [mW]     [dB]   [dBi]         [dBm]       [mW]    [dBm] [mW]     [dB]
  2402 -19.02 0.30         0.00     -18.72   0.013    30.00 1000.00 48.72   -0.40         -19.12      0.012   36.02 4000.00 55.14
  2440 -18.74 0.30         0.00     -18.44   0.014    30.00 1000.00 48.44   -0.40         -18.84      0.013   36.02 4000.00 54.86
  2480 -18.51 0.30         0.00     -18.21   0.015    30.00 1000.00 48.21   -0.40         -18.61      0.014   36.02 4000.00 54.63

Sample Calculation:
 Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss
 e.i.r.p. Result = Conducted Power Result + Antenna Gain
*The equipment and cables were not used for factor 0 dB of the data sheets.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                         Test report No.         : 12634949H-A-R2
                                                                                         Page                    : 20 of 36
                                                                                         Issued date             : January 28, 2019
                                                                                         FCC ID                  : SQK-7BLZ20


                                           Average Output Power
                               (Reference data for RF Exposure / SAR testing)

                     Report No.                          12634949H
                     Test place                          Ise EMC Lab. No.8 Measurement Room
                     Date                                December 5, 2018         January 23, 2019
                     Temperature / Humidity              23 deg. C / 48 % RH      25 deg. C / 40 % RH
                     Engineer                            Junki Nagatomi           Tomoki Matsui
                     Mode                                Tx BT LE

               Highest Power setting (4dBm)
                 Freq.   Reading Cable          Atten.          Result          Duty            Result
                                      Loss       Loss      (Time average)      factor   (Burst power average)
                [MHz]     [dBm]       [dB]       [dB]     [dBm]      [mW]       [dB]      [dBm]      [mW]
                 2402     -10.51      0.30      10.04     -0.17       0.96     2.38        2.21       1.66
                 2440     -10.47      0.30      10.04     -0.13       0.97     2.38        2.25       1.68
                 2480     -10.34      0.30      10.04      0.00       1.00     2.38        2.38       1.73


               Lowest Power setting (-20dBm)
                 Freq.  Reading Cable           Atten.         Result           Duty            Result
                                      Loss      Loss       (Time average)      factor   (Burst power average)
                [MHz]    [dBm]        [dB]      [dB]      [dBm]     [mW]        [dB]      [dBm]      [mW]
                 2402    -23.39       0.30      0.00      -23.09    0.005      2.38      -20.71     0.008
                 2440    -22.89       0.30      0.00      -22.59    0.006      2.38      -20.21     0.010
                 2480    -22.53       0.30      0.00      -22.23    0.006      2.38      -19.85     0.010

               Sample Calculation:
               Result (Time average) = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss
               Result (Burst power average) = Time average + Duty factor

               *The equipment and cables were not used for factor 0 dB of the data sheets.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                             Test report No.    : 12634949H-A-R2
                                                                             Page               : 21 of 36
                                                                             Issued date        : January 28, 2019
                                                                             FCC ID             : SQK-7BLZ20


                                              Burst rate confirmation

                     Report No.                   12634949H
                     Test place                   Ise EMC Lab. No.8 Measurement Room
                     Date                         December 5, 2018
                     Temperature / Humidity       23 deg. C / 48 % RH
                     Engineer                     Junki Nagatomi
                     Mode                         Tx BT LE

                                                             BLE
                                  Tx on / (Tx on + Tx off) =                   0.578
                                  Tx on / (Tx on + Tx off) * 100 =              57.8 %
                                  Duty factor = 10 * log (1.875 / 1.084) =      2.38 dB




* Since the burst rate is not different between the channels, the data has been obtained on the representative channel.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                         Test report No.               : 12634949H-A-R2
                                                                                                         Page                          : 22 of 36
                                                                                                         Issued date                   : January 28, 2019
                                                                                                         FCC ID                        : SQK-7BLZ20


                                                         Radiated Spurious Emission

          Report No.                              12634949H
          Test place                              Ise EMC Lab.
          Semi Anechoic Chamber                   No.2                               No.2                              No.3
          Date                                    December 8, 2018                   December 9, 2018                  December 13, 2018 (Night)
          Temperature / Humidity                  20 deg. C / 30 % RH                23 deg. C / 35 % RH               24 deg. C / 34 % RH
          Engineer                                Takafumi Noguchi                   Takumi Shimada                    Junki Nagatomi
                                                  (1 GHz - 10 GHz)                   (10 GHz - 26.5 GHz)               (Below 1 GHz)
          Mode                                    Tx BT LE 2402 MHz

            Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor Result            Limit  Margin             Remark
            消すな         [MHz]                [dBuV] [dB/m]          [dB]     [dB]       [dB]      [dBuV/m] [dBuV/m] [dB]
           Hori          120.018 QP             42.7       12.8        8.4     32.1             -      31.8       43.5   11.7
           Hori          129.240 QP             39.0       13.8        8.5     32.1             -      29.2       43.5   14.3
           Hori          168.008 QP             38.6       15.9        8.9     32.0             -      31.4       43.5   12.1
           Hori          247.410 QP             42.4       11.8        9.6     32.0             -      31.8       46.0   14.2
           Hori          300.072 QP             35.1       13.7       10.1     32.0             -      26.9       46.0   19.1
           Hori          432.012 QP             34.3       16.5       11.0     32.0             -      29.8       46.0   16.2
           Hori         2390.000 PK             46.6       27.7        5.1     34.4             -      45.0       73.9   28.9
           Hori         4804.000 PK             48.2       31.2        7.2     33.7             -      52.9       73.9   21.0
           Hori         7206.000 PK             47.2       35.5        8.6     33.6             -      57.7       73.9   16.2
           Hori         9608.000 PK             42.2       38.4        8.1     33.9             -      54.8       73.9   19.1 Floor noise
           Hori         2390.000 AV             36.0       27.7        5.1     34.4          2.4       36.8       53.9   17.1 *1)
           Hori         4804.000 AV             39.6       31.2        7.2     33.7          2.4       46.7       53.9    7.2
           Hori         7206.000 AV             38.8       35.5        8.6     33.6          2.4       51.7       53.9    2.2
           Hori         9608.000 AV             34.0       38.4        8.1     33.9             -      46.6       53.9    7.3 Floor noise
           Vert           50.520 QP             49.0       11.0        7.5     32.1             -      35.4       40.0    4.6
           Vert           60.051 QP             35.3        7.9        7.6     32.1             -      18.7       40.0   21.3
           Vert           94.009 QP             43.6        9.2        8.1     32.1             -      28.8       43.5   14.7
           Vert          120.021 QP             47.5       12.8        8.4     32.1             -      36.6       43.5    6.9
           Vert          129.252 QP             44.7       13.8        8.5     32.1             -      34.9       43.5    8.6
           Vert          168.003 QP             40.6       15.9        8.9     32.0             -      33.4       43.5   10.1
           Vert         2390.000 PK             46.1       27.7        5.1     34.4             -      44.5       73.9   29.4
           Vert         4804.000 PK             48.3       31.2        7.2     33.7             -      53.0       73.9   20.9
           Vert         7206.000 PK             46.8       35.5        8.6     33.6             -      57.3       73.9   16.6
           Vert         9608.000 PK             42.1       38.4        8.1     33.9             -      54.7       73.9   19.2 Floor noise
           Vert         2390.000 AV             36.4       27.7        5.1     34.4          2.4       37.2       53.9   16.7 *1)
           Vert         4804.000 AV             39.6       31.2        7.2     33.7          2.4       46.7       53.9    7.2
           Vert         7206.000 AV             38.3       35.5        8.6     33.6          2.4       51.2       53.9    2.7
           Vert         9608.000 AV             34.2       38.4        8.1     33.9             -      46.8       53.9    7.1 Floor noise
           Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier) + Duty factor
           *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
           消すな
           Distance factor:      1 GHz - 10 GHz        20log (3.75 m / 3.0 m) = 1.94 dB
           消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB
           *1) Not Out of Band emission(Leakage Power)




       20dBc Data Sheet
       Polarity  Frequency Detector Reading        Ant      Loss      Gain     Result    Limit Margin         Remark
                                                  Factor
                    [MHz]               [dBuV] [dB/m]       [dB]      [dB] [dBuV/m][dBuV/m] [dB]
       Hori        2402.000 PK             96.2     27.7       5.1      34.4      94.6          -        - Carrier
       Hori        2400.000 PK             64.4     27.8       5.1      34.4      62.9      74.6     11.7
       Vert        2402.000 PK             97.4     27.7       5.1      34.4      95.8          -        - Carrier
       Vert        2400.000 PK             65.7     27.8       5.1      34.4      64.2      75.8     11.6
       Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amprifier)

       Distance factor:      1 GHz - 10 GHz     20log (3.75 m / 3.0 m) = 1.94 dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                      Test report No.   : 12634949H-A-R2
                                                                      Page              : 23 of 36
                                                                      Issued date       : January 28, 2019
                                                                      FCC ID            : SQK-7BLZ20


                                        Radiated Spurious Emission
                                       (Reference Plot for band-edge)

            Report No.                 12634949H
            Test place                 Ise EMC Lab.
            Semi Anechoic Chamber      No.2
            Date                       December 8, 2018
            Temperature / Humidity     20 deg. C / 30 % RH
            Engineer                   Takafumi Noguchi
                                       (1 GHz - 10 GHz)
            Mode                       Tx BT LE 2402 MHz


                                                      Horizontal
           Restricted-band band-edge Plot                          Authorized-band band-edge Plot




               Trace Green : Peak Plot                                         20dBc Plot
             Trace Purple : Average Plot

                                                       Vertical
           Restricted-band band-edge Plot                          Authorized-band band-edge Plot




              Trace Green : Peak Plot                                          20dBc Plot
            Trace Purple : Average Plot
* Final result of restricted band edge was shown in tabular data.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                       Test report No.                : 12634949H-A-R2
                                                                                                       Page                           : 24 of 36
                                                                                                       Issued date                    : January 28, 2019
                                                                                                       FCC ID                         : SQK-7BLZ20


                                                       Radiated Spurious Emission

         Report No.                              12634949H
         Test place                              Ise EMC Lab.
         Semi Anechoic Chamber                   No.2                              No.2                              No.3
         Date                                    December 8, 2018                  December 9, 2018                  December 13, 2018 (Night)
         Temperature / Humidity                  20 deg. C / 30 % RH               23 deg. C / 35 % RH               24 deg. C / 34 % RH
         Engineer                                Takafumi Noguchi                  Takumi Shimada                    Junki Nagatomi
                                                 (1 GHz - 10 GHz)                  (10 GHz – 26.5 GHz)               (Below 1 GHz)
         Mode                                    Tx BT LE 2440 MHz

           Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor Result            Limit  Margin             Remark
           消すな         [MHz]                [dBuV] [dB/m]          [dB]     [dB]       [dB]      [dBuV/m] [dBuV/m] [dB]
          Hori          120.008 QP             41.3       12.8        8.4     32.1             -      30.4       43.5   13.1
          Hori          129.250 QP             37.8       13.8        8.5     32.1             -      28.0       43.5   15.5
          Hori          168.001 QP             36.9       15.9        8.9     32.0             -      29.7       43.5   13.8
          Hori          252.021 QP             40.0       12.0        9.7     32.0             -      29.7       46.0   16.3
          Hori          299.891 QP             35.2       13.7       10.1     32.0             -      27.0       46.0   19.0
          Hori          432.072 QP             33.3       16.5       11.0     32.0             -      28.8       46.0   17.2
          Hori         4880.000 PK             49.2       31.5        7.3     33.7             -      54.3       73.9   19.6
          Hori         7320.000 PK             46.8       35.9        8.5     33.6             -      57.6       73.9   16.3
          Hori         9760.000 PK             41.3       38.6        8.1     34.0             -      54.0       73.9   19.9 Floor noise
          Hori         4880.000 AV             41.9       31.5        7.3     33.7          2.4       49.4       53.9    4.5
          Hori         7320.000 AV             38.6       35.9        8.5     33.6          2.4       51.8       53.9    2.1
          Hori         9760.000 AV             32.3       38.6        8.1     34.0             -      45.0       53.9    8.9 Floor noise
          Vert           50.612 QP             48.2       11.0        7.5     32.1             -      34.6       40.0    5.4
          Vert           59.897 QP             37.2        7.9        7.6     32.1             -      20.6       40.0   19.4
          Vert           93.291 QP             43.4        9.1        8.1     32.1             -      28.5       43.5   15.0
          Vert          120.024 QP             46.8       12.8        8.4     32.1             -      35.9       43.5    7.6
          Vert          129.196 QP             44.2       13.8        8.5     32.1             -      34.4       43.5    9.1
          Vert          169.005 QP             38.7       15.9        8.9     32.0             -      31.5       43.5   12.0
          Vert         4880.000 PK             48.5       31.5        7.3     33.7             -      53.6       73.9   20.3
          Vert         7320.000 PK             45.3       35.9        8.5     33.6             -      56.1       73.9   17.8
          Vert         9760.000 PK             41.3       38.6        8.1     34.0             -      54.0       73.9   19.9 Floor noise
          Vert         4880.000 AV             40.5       31.5        7.3     33.7          2.4       48.0       53.9    5.9
          Vert         7320.000 AV             37.0       35.9        8.5     33.6          2.4       50.2       53.9    3.7
          Vert         9760.000 AV             32.2       38.6        8.1     34.0             -      44.9       53.9    9.0 Floor noise
          Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier) + Duty factor
          *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
          消すな
          Distance factor:      1 GHz - 10 GHz        20log (3.75 m / 3.0 m) = 1.94 dB
          消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                       Test report No.                : 12634949H-A-R2
                                                                                                       Page                           : 25 of 36
                                                                                                       Issued date                    : January 28, 2019
                                                                                                       FCC ID                         : SQK-7BLZ20


                                                       Radiated Spurious Emission

         Report No.                              12634949H
         Test place                              Ise EMC Lab.
         Semi Anechoic Chamber                   No.2                              No.2                              No.3
         Date                                    December 8, 2018                  December 9, 2018                  December 13, 2018 (Night)
         Temperature / Humidity                  20 deg. C / 30 % RH               23 deg. C / 35 % RH               24 deg. C / 34 % RH
         Engineer                                Takafumi Noguchi                  Takumi Shimada                    Junki Nagatomi
                                                 (1 GHz - 10 GHz)                  (10 GHz – 26.5 GHz)               (Below 1 GHz)
         Mode                                    Tx BT LE 2480 MHz

           Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor Result            Limit  Margin             Remark
           消すな         [MHz]                [dBuV] [dB/m]          [dB]     [dB]       [dB]      [dBuV/m] [dBuV/m] [dB]
          Hori          120.012 QP             42.6       12.8        8.4     32.1             -      31.7       43.5   11.8
          Hori          129.237 QP             39.2       13.8        8.5     32.1             -      29.4       43.5   14.1
          Hori          168.012 QP             38.4       15.9        8.9     32.0             -      31.2       43.5   12.3
          Hori          252.021 QP             42.3       12.0        9.7     32.0             -      32.0       46.0   14.0
          Hori          299.839 QP             34.9       13.7       10.1     32.0             -      26.7       46.0   19.3
          Hori          432.069 QP             33.6       16.5       11.0     32.0             -      29.1       46.0   16.9
          Hori         2483.500 PK             53.4       27.5        5.1     34.4             -      51.6       73.9   22.3
          Hori         4960.000 PK             49.3       31.7        7.3     33.7             -      54.6       73.9   19.3
          Hori         7440.000 PK             44.1       36.1        8.6     33.6             -      55.2       73.9   18.7
          Hori         9920.000 PK             41.4       38.5        8.2     34.0             -      54.1       73.9   19.8 Floor noise
          Hori         2483.500 AV             40.8       27.5        5.1     34.4          2.4       41.4       53.9   12.5 *1)
          Hori         4960.000 AV             41.0       31.7        7.3     33.7          2.4       48.7       53.9    5.2
          Hori         7440.000 AV             34.4       36.1        8.6     33.6          2.4       47.9       53.9    6.0
          Hori         9920.000 AV             33.0       38.5        8.2     34.0             -      45.7       53.9    8.2 Floor noise
          Vert           50.240 QP             48.4       11.2        7.5     32.1             -      35.0       40.0    5.0
          Vert           59.998 QP             36.8        7.9        7.6     32.1             -      20.2       40.0   19.8
          Vert           93.511 QP             42.2        9.1        8.1     32.1             -      27.3       43.5   16.2
          Vert          120.012 QP             47.1       12.8        8.4     32.1             -      36.2       43.5    7.3
          Vert          129.243 QP             44.5       13.8        8.5     32.1             -      34.7       43.5    8.8
          Vert          168.012 QP             40.7       15.9        8.9     32.0             -      33.5       43.5   10.0
          Vert         2483.500 PK             54.0       27.5        5.1     34.4             -      52.2       73.9   21.7
          Vert         4960.000 PK             47.2       31.7        7.3     33.7             -      52.5       73.9   21.4
          Vert         7440.000 PK             42.5       36.1        8.6     33.6             -      53.6       73.9   20.3
          Vert         9920.000 PK             41.5       38.5        8.2     34.0             -      54.2       73.9   19.7 Floor noise
          Vert         2483.500 AV             41.3       27.5        5.1     34.4          2.4       41.9       53.9   12.0 *1)
          Vert         4960.000 AV             39.2       31.7        7.3     33.7          2.4       46.9       53.9    7.0
          Vert         7440.000 AV             33.7       36.1        8.6     33.6          2.4       47.2       53.9    6.7
          Vert         9920.000 AV             33.1       38.5        8.2     34.0             -      45.8       53.9    8.1 Floor noise
          Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier) + Duty factor
          *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
          消すな
          Distance factor:      1 GHz - 10 GHz        20log (3.75 m / 3.0 m) = 1.94 dB
          消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB
          *1) Not Out of Band emission(Leakage Power)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                 Test report No.   : 12634949H-A-R2
                                                                 Page              : 26 of 36
                                                                 Issued date       : January 28, 2019
                                                                 FCC ID            : SQK-7BLZ20


                                        Radiated Spurious Emission
                                       (Reference Plot for band-edge)

            Report No.                 12634949H
            Test place                 Ise EMC Lab.
            Semi Anechoic Chamber      No.2
            Date                       December 8, 2018
            Temperature / Humidity     20 deg. C / 30 % RH
            Engineer                   Takafumi Noguchi
                                       (1 GHz - 10 GHz)
            Mode                       Tx BT LE 2480 MHz


                                                 Horizontal
                                       Restricted-band band-edge Plot




                                           Trace Green : Peak Plot
                                         Trace Purple : Average Plot

                                                   Vertical
                                       Restricted-band band-edge Plot




                                       Trace Green : Peak Plot
                                     Trace Purple : Average Plot
* Final result of restricted band edge was shown in tabular data.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                    Test report No.           : 12634949H-A-R2
                                                                                                    Page                      : 27 of 36
                                                                                                    Issued date               : January 28, 2019
                                                                                                    FCC ID                    : SQK-7BLZ20


                                                                 Radiated Spurious Emission
                                                                   (Plot data, Worst case)

          Report No.                                       12634949H
          Test place                                       Ise EMC Lab.
          Semi Anechoic Chamber                            No.2                        No.2                      No.3
          Date                                             December 8, 2018            December 9, 2018          December 13, 2018 (Night)
          Temperature / Humidity                           20 deg. C / 30 % RH         23 deg. C / 35 % RH       24 deg. C / 34 % RH
          Engineer                                         Takafumi Noguchi            Takumi Shimada            Junki Nagatomi
                                                           (1 GHz - 10 GHz)            (10 GHz – 26.5 GHz)       (Below 1 GHz)
          Mode                                             Tx BT LE 2480 MHz



                                                                                 Horizontal
                                           80

                                           70

                                           60
                 Field strength [dBuV/m]




                                           50

                                           40

                                           30

                                           20

                                           10

                                           0
                                                10               100                         1000                  10000
                                                                                  Frequency [MHz]

                                                     QP   Peak         Average         QP Limit     Peak Limit        Average Limit




                                                                                  Vertical
                                           80

                                           70

                                           60
                 Field strength [dBuV/m]




                                           50

                                           40

                                           30

                                           20

                                           10

                                           0
                                                10               100                         1000                  10000
                                                                                  Frequency [MHz]

                                                     QP   Peak         Average         QP Limit     Peak Limit        Average Limit



*These plots data contains sufficient number to show the trend of characteristic features for EUT.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                   Test report No.                 : 12634949H-A-R2
                                                                                                   Page                            : 28 of 36
                                                                                                   Issued date                     : January 28, 2019
                                                                                                   FCC ID                          : SQK-7BLZ20


                                                    Conducted Spurious Emission

                           Report No.                          12634949H
                           Test place                          Ise EMC Lab. No.8 Measurement Room
                           Date                                December 5, 2018
                           Temperature / Humidity              23 deg. C / 48 % RH
                           Engineer                            Junki Nagatomi
                           Mode                                Tx BT LE 2402 MHz



                           9 kHz - 150 kHz                                                            150 kHz - 30 MHz




   Frequency     Reading      Cable    Attenuator Antenna          N          EIRP      Distance     Ground             E             Limit    M argin   Remark
                              Loss       Loss      Gain*        (Number                              bounce     (field strength)
     [kHz]        [dBm]       [dB]        [dB]        [dBi]    of Output)     [dBm]       [m]         [dB]        [dBuV/m]          [dBuV/m]    [dB]
        13.23     -94.9       0.30          9.7        2.0           1      -82.9       300               6.0             -21.7         45.1      66.8
       225.00     -89.3       0.30          9.7        2.0           1      -77.3       300               6.0             -16.1         20.5      36.6
  E [dBuV/m] = EIRP [dBm] - 20 log (Distance [m]) + Ground bounce [dB] + 104.8 [dBuV/m]
  EIRP[dBm] = Reading [dBm] + Cable loss [dB] + Attenuator Loss [dB] + Antenna gain [dBi] + 10 * log (N)
  N: Number of output
  *2.0 dBi was applied to the test result based on KDB 558074 since antenna gain was less than 2.0 dBi.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                   Test report No.                 : 12634949H-A-R2
                                                                                                   Page                            : 29 of 36
                                                                                                   Issued date                     : January 28, 2019
                                                                                                   FCC ID                          : SQK-7BLZ20


                                                    Conducted Spurious Emission

                           Report No.                          12634949H
                           Test place                          Ise EMC Lab. No.8 Measurement Room
                           Date                                December 5, 2018
                           Temperature / Humidity              23 deg. C / 48 % RH
                           Engineer                            Junki Nagatomi
                           Mode                                Tx BT LE 2440 MHz



                           9 kHz - 150 kHz                                                            150 kHz - 30 MHz




   Frequency     Reading      Cable    Attenuator Antenna          N          EIRP      Distance     Ground             E             Limit    M argin   Remark
                              Loss       Loss      Gain*        (Number                              bounce     (field strength)
     [kHz]        [dBm]       [dB]        [dB]        [dBi]    of Output)     [dBm]       [m]         [dB]        [dBuV/m]          [dBuV/m]    [dB]
        10.29     -97.4       0.30          9.7        2.0           1      -85.4       300               6.0             -24.2         47.3      71.5
       175.00     -89.8       0.30          9.7        2.0           1      -77.8       300               6.0             -16.6         22.7      39.3
  E [dBuV/m] = EIRP [dBm] - 20 log (Distance [m]) + Ground bounce [dB] + 104.8 [dBuV/m]
  EIRP[dBm] = Reading [dBm] + Cable loss [dB] + Attenuator Loss [dB] + Antenna gain [dBi] + 10 * log (N)
  N: Number of output
  *2.0 dBi was applied to the test result based on KDB 558074 since antenna gain was less than 2.0 dBi.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                   Test report No.                 : 12634949H-A-R2
                                                                                                   Page                            : 30 of 36
                                                                                                   Issued date                     : January 28, 2019
                                                                                                   FCC ID                          : SQK-7BLZ20


                                                    Conducted Spurious Emission

                           Report No.                          12634949H
                           Test place                          Ise EMC Lab. No.8 Measurement Room
                           Date                                December 5, 2018
                           Temperature / Humidity              23 deg. C / 48 % RH
                           Engineer                            Junki Nagatomi
                           Mode                                Tx BT LE 2480 MHz



                           9 kHz - 150 kHz                                                            150 kHz - 30 MHz




   Frequency     Reading      Cable    Attenuator Antenna          N          EIRP      Distance     Ground             E             Limit    M argin   Remark
                              Loss       Loss      Gain*        (Number                              bounce     (field strength)
     [kHz]        [dBm]       [dB]        [dB]        [dBi]    of Output)     [dBm]       [m]         [dB]        [dBuV/m]          [dBuV/m]    [dB]
         9.24     -97.3       0.30          9.7        2.0           1      -85.3       300               6.0             -24.0         48.2      72.2
       175.00     -89.4       0.30          9.7        2.0           1      -77.4       300               6.0             -16.1         22.7      38.8
  E [dBuV/m] = EIRP [dBm] - 20 log (Distance [m]) + Ground bounce [dB] + 104.8 [dBuV/m]
  EIRP[dBm] = Reading [dBm] + Cable loss [dB] + Attenuator Loss [dB] + Antenna gain [dBi] + 10 * log (N)
  N: Number of output
  *2.0 dBi was applied to the test result based on KDB 558074 since antenna gain was less than 2.0 dBi.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                  Test report No.          : 12634949H-A-R2
                                                                                  Page                     : 31 of 36
                                                                                  Issued date              : January 28, 2019
                                                                                  FCC ID                   : SQK-7BLZ20


                                                       Power Density

                     Report No.                     12634949H
                     Test place                     Ise EMC Lab. No.8 Measurement Room
                     Date                           December 5, 2018
                     Temperature / Humidity         23 deg. C / 48 % RH
                     Engineer                       Junki Nagatomi
                     Mode                           Tx BT LE



                Freq.      Reading       Cable     Atten. Result Limit Margin
                                         Loss       Loss
               [MHz]        [dBm]        [dB]       [dB] [dBm] [dBm] [dB]
              2402.00       -25.25       0.30      10.04 -14.91 8.00   22.91
              2440.00       -25.16       0.30      10.04 -14.82 8.00   22.82
              2480.00       -25.28       0.30      10.04 -14.94 8.00   22.94

              Sample Calculation:
              Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss


              *The equipment and cables were not used for factor 0 dB of the data sheets.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                 Test report No.   : 12634949H-A-R2
                                                                 Page              : 32 of 36
                                                                 Issued date       : January 28, 2019
                                                                 FCC ID            : SQK-7BLZ20


                                                 Power Density

                                                        BLE
                                                      2402 MHz




                                                      2440 MHz




                                                      2480 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                 Test report No.           : 12634949H-A-R2
                                                                                 Page                      : 33 of 36
                                                                                 Issued date               : January 28, 2019
                                                                                 FCC ID                    : SQK-7BLZ20


APPENDIX 2: Test instruments
Test Instruments
Test    LIMS ID Description                 Manufacturer       Model                     Serial          Last          Calibration Cal Int
Item                                                                                                     Calibration   Due Date
                                                                                                         Date
AT      141806   Power Meter                ANRITSU            ML2495A                   6K00003348      10/31/2018    10/31/2019   12
AT      141841   Power sensor               ANRITSU            MA2411B                   11598           10/31/2018    10/31/2019   12
AT      141567   Thermo-Hygrometer          CUSTOM             CTH-201                   0008            01/24/2018    01/31/2019   12
AT      141244   Attenuator(10dB)           WEINSCHEL          WA8-10-34                 A198            02/28/2018    02/28/2019   12
AT      141269   Attenuator(10dB) 1-18GHz   Orient Microwave   BX10-0476-00              -               03/12/2018    03/31/2019   12
AT,RE   141902   Spectrum Analyzer          AGILENT            E4440A                    MY46187105 10/04/2018         10/31/2019   12
RE      141579   Pre Amplifier              AGILENT            8449B                     3008A02142      01/23/2018    01/31/2019   12
RE      141392   Microwave Cable            Junkosha           MWX221                    1604S253(1 m) / 08/08/2018    08/31/2019   12
                                                                                         1608S087(5 m)
RE,CE 141556     Thermo-Hygrometer          CUSTOM               CTH-201                 0003            12/05/2018    12/31/2019 12
RE    141404     High Pass Filter 3.5-24GHz TOKIMEC              TF323DCA                601             05/14/2018    05/31/2019 12
RE    142006     AC2_Semi Anechoic          TDK                  Semi Anechoic Chamber   DA-06902        04/01/2018    04/30/2019 12
                 Chamber(SVSWR)                                  3m
RE,CE   141542   Digital Tester             Fluke Corporation FLUKE 26-3                 78030611       08/21/2018     08/31/2019   12
RE,CE   141152   EMI measurement program TSJ                     TEPTO-DV                -              -              -            -
RE      141512   Horn Antenna 1-18GHz       Schwarzbeck          BBHA9120D               254            06/06/2018     06/30/2019   12
RE      141232   High Pass Filter           UL Japan             HPF SELECTOR            001            09/19/2018     09/30/2019   12
                 3.5-18.0GHz
RE,CE   142228   Measure                    KOMELON              KMC-36                  -              -              -            -
RE      141503   Horn Antenna 18-26.5GHz EMCO                    3160-09                 1265           06/06/2018     06/30/2019   12
CE      141248   Attenuator                 JFW Industries, Inc. 50FP-013H2 N            -              12/06/2018     12/31/2019   12
CE      141222   Coaxial Cable              FUJIKURA             3D-2W(12m)/5D-2W(5m)/   -              02/23/2018     02/28/2019   12
                                                                 5D-2W(0.8m)/5D-2W(1m)
CE    141357     LISN(AMN)                  Schwarzbeck          NSLK8127                8127-729       07/24/2018 07/31/2019 12
RE,CE 141942     Test Receiver              Rohde & Schwarz ESCI                         100300         08/08/2018 08/31/2019 12
RE    142008     AC3_Semi Anechoic          TDK                  Semi Anechoic Chamber   DA-10005       06/26/2018 06/30/2020 24
                 Chamber(NSA)                                    3m
RE      148897   Attenuator                 KEYSIGHT             8491A                   MY52462349     12/18/2017     12/31/2018   12
RE      141554   Thermo-Hygrometer          CUSTOM               CTH-180                 1301           01/24/2018     01/31/2019   12
RE      142183   Measure                    KOMELON              KMC-36                  -              -              -            -
RE      141532   DIGITAL HiTESTER           HIOKI                3805                    51201197       01/09/2018     01/31/2019   12
RE      141424   Biconical Antenna          Schwarzbeck          BBA9106                 1915           06/04/2018     06/30/2019   12
RE      141266   Logperiodic Antenna        Schwarzbeck          VUSLP9111B              911B-191       06/04/2018     06/30/2019   12
                 (200-1000MHz)
RE      141323   Coaxial cable              UL Japan             -                       -              07/03/2018 07/31/2019 12
RE      141583   Pre Amplifier              SONOMA               310                     260833         02/27/2018 02/28/2019 12
                                            INSTRUMENT
RE      141949   Test Receiver              Rohde & Schwarz ESCI                         100767         08/06/2018 08/31/2019 12
*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int are instruments that Calibration is not
required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means
of an unbroken chains of calibrations.

Test item:            CE: Conducted Emission test
                      RE: Radiated Emission test
                      AT: Antenna Terminal Conducted test




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2019-03-31 17:58:25
Document Modified: 2019-03-31 17:58:25

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC