RF Exposure

FCC ID: SK9SNIC1

RF Exposure Info

Download: PDF
FCCID_3763243

                                              Certification Test Report

                                                            FCC ID: SK9SNIC1
                                                             IC: 864G-SNIC1

                                  FCC Rule Part: 1.1310
                    ISED Canada Radio Standards Specification: RSS-102

                                           Report Number: AT72133597-4P0


                                                        Manufacturer: Itron, Inc.
                                                           Model: SNIC1

                                          Test Begin Date: December 19, 2017
                                           Test End Date: December 19, 2017

                                         Report Issue Date: February 23, 2018




                                 FOR THE SCOPE OF ACCREDITATION UNDER Certificate Number: AT-2021

 This report must not be used by the client to claim product certification, approval, or endorsement by ANAB, NIST, or any agency of
                                                       the Federal Government.

           Prepared by:                                                                             Reviewed by:




           Ryan McGann                                                                              Steve O'Steen
           Senior Engineer                                                                          Service Line Manager, EMC
           TÜV SÜD America Inc.                                                                     TÜV SÜD America Inc.
This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of TÜV SÜD America Inc. The results contained
                                               in this report are representative of the sample(s) submitted for evaluation.
                                                          This report contains 11 pages
                            5015 B.U. Bowman Drive Buford, GA 30518 USA Vo: 770-831-8048 Fax: 770-831-8598


                                                         TABLE OF CONTENTS
1      GENERAL ............................................................................................................................................ 3
    1.1       PURPOSE.......................................................................................................................................... 3
    1.2       MANUFACTURER INFORMATION ...................................................................................................... 3
    1.3       PRODUCT DESCRIPTION ................................................................................................................... 3
    1.4       TEST METHODOLOGY AND CONSIDERATIONS ................................................................................. 4
2      TEST FACILITIES .............................................................................................................................. 5
    2.1     LOCATION ....................................................................................................................................... 5
    2.2     LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS ................................................ 5
    2.3     RADIATED EMISSIONS TEST SITE DESCRIPTION .............................................................................. 6
       2.3.1    Semi-Anechoic Chamber Test Site .......................................................................................... 6
3      APPLICABLE STANDARD REFERENCES.................................................................................... 7

4      LIST OF TEST EQUIPMENT ............................................................................................................ 7

5      SUPPORT EQUIPMENT .................................................................................................................... 8

6      EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ........................................................... 8

7      SUMMARY OF TESTS ....................................................................................................................... 9
    7.1     MAXIMUM PERMISSIBLE EXPOSURE – FCC: SECTION 1.1310; ISED CANADA: RSS-102 4............. 9
       7.1.1   Measurement Procedure ......................................................................................................... 9
       7.1.2   Measurement Results .............................................................................................................. 9
       7.1.3   Summation of MPE Ratios – Simultaneous Transmissions ...................................................10
8      ESTIMATION OF MEASUREMENT UNCERTAINTY ...............................................................11

9      CONCLUSION ....................................................................................................................................11




                    5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


    Models: SNIC1                   FCC ID: SK9SNIC1                        IC: 864G-SNIC1

1     GENERAL

1.1    Purpose

The purpose of this report is to demonstrate compliance with Part 1 Subpart I of the FCC’s Code
of Federal Regulations and Innovation, Science, and Economic Development Canada’s Radio
Standards Specification RSS-102 Certification for a Class II Permissive Change.

The purpose of this Class II Permissive Change is to add a new antenna and host combination.

1.2    Manufacturer Information

Itron, Inc.
313 N Hwy 11
West Union, SC 29696

1.3    Product Description

The Itron Smart Network Interface Card (model: SNIC1) module is built on Itron’s IPv6 OpenWay
platform, and includes the Adaptive Communications Technology (ACT). It can process, analyze,
communicate and react in real-time. Adaptive communications enable devices to interact with
each other while dynamically switching between Radio Frequency (RF) and Power Line Carrier
(PLC) to ensure the fastest and most reliable communications path. The communication module
utilizes 900 MHz radio frequency (RF), power line carrier (carrier current system) and 2.4 GHz
Wi-Fi operation bands.

The purpose of this Class II Permissive Change is to add new antennas and host combination.
For this Class II Permissive Change, the SNIC1 was integrated into the Itron, Inc. RN-ERT
Gateway STAR (FCC ID: EO9ORRNA). The new 900MHz antenna is a PCTEL BOA9022NM-ITR
used only with the RN-ERT Gateway STAR host. The 2.4 GHz antenna is an internal microstrip
patch to the RN-ERT Gateway STAR host device.

This test report documents the compliance of the maximum permissible exposure for uncontrolled
exposure of a fixed device.

2.4GHz WiFi Technical Information:
             Detail                                     Description
  Frequency Range               2412 – 2462 MHz
  Number of Channels            802.11b/g/n (HT 20): 11
                                802.11n (HT 40): 7
  Modulation Format             802.11b: DSSS (DBPSK / DQPSK / CCK)
                                802.11g/n (HT 20/40): OFDM (BPSK / QPSK / 16QAM /
                                64QAM)
  Data Rates                    802.11b: 1 – 11 Mbps
                                802.11g: 6 – 54 Mbps
                                802.11n (HT 20): 6.5 – 72 Mbps
                                802.11n (HT 40): 13.5 – 150 Mbps
  Number of Inputs/Outputs      1T1R
  Operating Voltage             24 Vdc
  Antenna Type / Gain           Micro Strip Patch Antenna / 3 dBi
                                Micro Strip Patch Antenna / 2.15 dBi (new, in host)




Report No: AT72133597-4P0                TÜV SÜD America, Inc.                         Page 3


  Models: SNIC1                    FCC ID: SK9SNIC1                        IC: 864G-SNIC1

900MHz FHSS Radio Technical Information:
                Detail                                   Description
 Frequency Range                     902.2 – 927.8 MHz
                                    FSK 10kbps: 513
                                    FSK 50kbps: 64
 Number of Channels                 FSK 150kbps: 64
                                    OFDM:           64
                                    DSSS:           64
 Modulation Format                   FSK, OFDM, DSSS
                                    FSK: 10, 50, 150
 Data Rates (kbps)                  OFDM: 200, 600
                                    DSSS: 6.25, 12.5
 Operating Voltage                   24Vdc
                                    Micro Strip Patch Antenna / 2.5 dBi
 Antenna Type(s) / Gain(s)
                                    PCTEL BOA9022NM-ITR / 2.6 dBi (new)

900MHz Hybrid Radio Technical Information
             Detail                                    Description
  Frequency Range              902.8 – 926.8 MHz
  Number of Channels           31
  Modulation Format            OFDM
  Data Rates                   1200kbps
  Operating Voltage            24Vdc
  Antenna Type / Gain          Micro Strip Patch Antenna / 2.5 dBi
                               PCTEL BOA9022NM-ITR / 2.6 dBi (new)

900MHz RN-ERT Gateway STAR Technical Information (FCC ID: EO9ORRN)
             Detail                                Description
  Frequency Range         902 – 928 MHz ISM Band
  Number of Channels      N/A
  Modulation Format       N/A
  Data Rates              N/A
  Operating Voltage       120Vac / 60Hz
  Antenna Type / Gain     Monopole (attached) / 5.15 dBi

Test Sample Serial Number:     630000C43E

Test Sample Condition: The test samples were provided in good working order with no visible
defects.

1.4    Test Methodology and Considerations
The data presented in this report represents the worst case where applicable. The worst-case
data rate for the 2.4GHz WiFi radio was 802.11b mode at 5.5 MBPS. The worst-case data rate for
the 900MHz radio was OFDM at 1200kbps. The EUT is not capable of operating in frequency
hopping mode and the Hybrid mode simultaneously.

The maximum permissible exposure for the RN-ERT Gateway STAR was measured independent
of the maximum permissible exposure of the SNIC1 evaluated in the host device. The measured
maximum permissible exposure for the RN-ERT Gateway STAR is reported with the original
certification of the RN-ERT Gateway STAR (FCC ID: EO9ORRNA). The worst case measured
values of the host device were included in the summation of maximum permissible exposure
ratios.

The EUT was evaluated for maximum permissible exposure in a typical host. The data presented
in this report represents the worst-case mode of operation.

Report No: AT72133597-4P0                TÜV SÜD America, Inc.                        Page 4


    Models: SNIC1                   FCC ID: SK9SNIC1                          IC: 864G-SNIC1

2     TEST FACILITIES

2.1     Location

The radiated and conducted emissions test sites are located at the following address:

      TÜV SÜD America, Inc.
      5015 B.U. Bowman Drive
      Buford, GA 30518
      Phone: (770) 831-8048
      Fax: (770) 831-8598

2.2     Laboratory Accreditations/Recognitions/Certifications

TÜV SÜD America, Inc. is accredited to ISO/IEC 17025 by the ANSI-ASQ National Accreditation
Board/ANAB accreditation program, and has been issued certificate number AT-2021 in
recognition of this accreditation. Unless otherwise specified, all tests methods described within
this report are covered under the ISO/IEC 17025 scope of accreditation.

The Semi-Anechoic Chamber Test Site, Open Area Test Site (OATS) and Conducted Emissions
Site have been fully described, submitted to, and accepted by the FCC, ISED Canada and the
Japanese Voluntary Control Council for Interference by information technology equipment.

FCC Registration Number: 391271
ISED Canada Lab Code: IC 23597
VCCI Member Number: 1831
•     VCCI OATS Registration Number R-1526
•     VCCI Conducted Emissions Site Registration Number: C-1608




Report No: AT72133597-4P0                 TÜV SÜD America, Inc.                          Page 5


  Models: SNIC1                       FCC ID: SK9SNIC1                           IC: 864G-SNIC1

2.3     Radiated Emissions Test Site Description

2.3.1    Semi-Anechoic Chamber Test Site

The Semi-Anechoic Chamber Test Site consists of a 20’ x 30’ x 18’ shielded enclosure. The
chamber is lined with Toyo Ferrite Grid Absorber, model number FFG-1000. The ferrite tile grid is
101 x 101 x 19mm thick and weighs approximately 550 grams. These tiles are mounted on steel
panels and installed directly on the inner walls of the chamber.

The turntable is 150cm in diameter and is located 160cm from the back wall of the chamber. The
chamber is grounded via 1 - 8’ copper ground rod, installed at the center of the back wall, it is
bound to the ground plane using 3/4" stainless steel braided cable.

The turntable is all steel, flush mounted table installed in an all steel frame. The table is remotely
operated from inside the control room located 25’ from the range. The turntable is electrically
bonded to the surrounding ground plane via steel fingers installed on the edge of the turn table.
The steel fingers make constant contact with the ground plane during operation.

Behind the turntable is a 3’ x 6’ x 4’ deep shielded pit used for support equipment if necessary.
The pit is equipped with 1 - 4” PVC chases from the turntable to the pit that allow for cabling to
the EUT if necessary. The underside of the turntable can be accessed from the pit so cables can
be supplied to the EUT from the pit.

A diagram of the Semi-Anechoic Chamber Test Site is shown in Figure 2.3-1 below:




                                             3 Meters


                                                                         5 Feet
                                                                        Diameter




                                                                                    20 Feet


                                               30 Feet
                        Figure 2.3-1: Semi-Anechoic Chamber Test Site




Report No: AT72133597-4P0                   TÜV SÜD America, Inc.                             Page 6


    Models: SNIC1                               FCC ID: SK9SNIC1                             IC: 864G-SNIC1

3      APPLICABLE STANDARD REFERENCES

The following standards were used:

             ANSI C63.4-2014: American National Standard for Methods of Measurement of Radio-Noise
              Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz.
             ANSI C63.10-2013: American National Standard of Procedures for Compliance Testing of
              Unlicensed Wireless Devices.
             IEEE C95.3-2002: IEEE Recommended Practice for Measurements and Computations of Radio
              Frequency Electromagnetic Fields with Respect to Human Exposure to Such Fields, 100 kHz to
              300 GHz.
             US Code of Federal Regulations (CFR): Title 47, Part 1, Subpart I: Procedures Implementing the
              National Environmental Policy Act of 1969, 2017
             FCC KDB 447498 D01 General RF Exposure Guidance v06, Oct. 23, 2015.
             ISED Canada Radio Standards Specification: RSS-102 – Radio Frequency (RF) Exposure
              Compliance of Radiocommunications Apparatus (All Frequency Bands), Issue 5, March 2015.

4      LIST OF TEST EQUIPMENT

The calibration interval of test equipment is annually or the manufacturer’s recommendations.
Where the calibration interval deviates from the annual cycle based on the instrument
manufacturer’s recommendations, it shall be stated below.

                                          Table 4-1: Test Equipment
                                                                                                       Calibration
    AssetID         Manufacturer      Model #      Equipment Type   Serial #   Last Calibration Date    Due Date
    RE137           ETS-Lindgren      HI-6005          Probes        23667          8/11/2017          8/11/2018
NOTE: All test equipment was used only during active calibration cycles.




Report No: AT72133597-4P0                           TÜV SÜD America, Inc.                                   Page 7


    Models: SNIC1                  FCC ID: SK9SNIC1                    IC: 864G-SNIC1

5       SUPPORT EQUIPMENT

                               Table 5-1: Support Equipment
Item        Equipment Type          Manufacturer         Model/Part       Serial Number
                                                           Number
                                                       RN-ERT Gateway
    1         Host Device              Itron, Inc.                          320483111
                                                            STAR

                                Table 5-2: Cable Description
Cable          Cable Type          Length      Shield               Termination
  A          AC Power Cable        1.75 m        No          Host Device to AC Mains
                                                          Host Device – Reference Ground
    B         Ground Braid         1.75 m        No
                                                                       Plane


6       EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM




                                            EUT

                                                          B
                                              1



                                                  A




                                          AC Mains

                            Figure 6-1: Test Setup Block Diagram




Report No: AT72133597-4P0               TÜV SÜD America, Inc.                     Page 8


    Models: SNIC1                                      FCC ID: SK9SNIC1                                                    IC: 864G-SNIC1

7     SUMMARY OF TESTS

Along with the tabular data shown below, plots were taken of all signals deemed important
enough to document.

7.1     Maximum Permissible Exposure – FCC: Section 1.1310; ISED Canada: RSS-102 4

7.1.1    Measurement Procedure

The EUT was placed on a non-conductive platform in the center of the turntable at a height of 1.5
meters above the ground plane. The measurement probe was located 20 centimeters away from
the EUT on an adjustable antenna mast. The EUT was rotated through 360 degrees so that the
maximum radiated emissions level would be detected. The mast was adjusted until the evaluated
results are less than 10% of the applicable limit. Once a stable reading was obtained, the
maximum was recorded. The azimuth and elevation leading to the direction of maximum
exposure was identified. The evaluation points in the horizontal plane were along radials
extending from the antenna axis 45 degrees apart starting from the direction of maximum
exposure.

7.1.2    Measurement Results
Performed by: Ryan McGann

                            Table 7.1.2-1: Maximum Permissible Exposure – 900MHz Radio
                                                       Probe      Probe       Field      Power                     ISED Canada     Result
         Frequency Distance Azimuth Elevation                     Factor                               FCC Limit
                                                       Display              Strength     Density                       Limit
                                                                                              2     2                        2
           (MHz)      cm         degrees    cm          V/m                     V/m     mW/cm mW/cm                 mW/cm
             914.8          20         0      152       11.468       1.26        14.450   0.055 0.610                   0.277    PASS
             914.8          20        45      153        8.189       1.26        10.318   0.028 0.610                   0.277    PASS
             914.8          20        90      160        6.021       1.26         7.586   0.015 0.610                   0.277    PASS
             914.8          20       135      158        7.201       1.26         9.073   0.022 0.610                   0.277    PASS
             914.8          20       180      166         7.91       1.26         9.967   0.026 0.610                   0.277    PASS
             914.8          20       225      176        6.475       1.26         8.159   0.018 0.610                   0.277    PASS
             914.8          20       270      152        9.402       1.26        11.847   0.037 0.610                   0.277    PASS
             914.8          20       315      151       10.538       1.26        13.278   0.047 0.610                   0.277    PASS

                             Table 7.1.2-2: Maximum Permissible Exposure – 802.11 Radio
                                                       Probe      Probe       Field      Power                     ISED Canada    Result
          Frequency Distance Azimuth Elevation                    Factor                               FCC Limit
                                                       Display              Strength     Density                       Limit
           (MHz)       cm        degrees    cm          V/m                     V/m     mW/cm2 mW/cm2               mW/cm2
              2437          20         0      161        1.151       1.38         1.588   0.001  1.000                  0.540    PASS
              2437          20        45      172        0.741       1.38         1.023   0.000  1.000                  0.540    PASS
              2437          20        90      166        0.758       1.38         1.046   0.000  1.000                  0.540    PASS
              2437          20       135      165        0.718       1.38         0.991   0.000  1.000                  0.540    PASS
              2437          20       180      173        0.979       1.38         1.351   0.000  1.000                  0.540    PASS
              2437          20       225      151        0.675       1.38         0.932   0.000  1.000                  0.540    PASS
              2437          20       270      155        0.713       1.38         0.984   0.000  1.000                  0.540    PASS
              2437          20       315      103        0.881       1.38         1.216   0.000  1.000                  0.540    PASS


                     Table 7.1.2-3: Maximum Permissible Exposure – RN-ERT Gateway STAR
                     Frequency       Maximum Exposure            Maximum Exposure        FCC Limit       ISED Canada Limit
                                                   2                        2                      2                 2
                       (MHz)               mW/cm                      W/m                mW/cm                 W/m
                           915                         0.180                     1.800     0.600                         2.700
Note: The measured values from Table 7.1.2-3 were taken from the maximum permissible exposure report of the
original filing of the RN-ERT Gateway STAR (FCC ID: EO9ORRNA). These values are included in this report for
summation of maximum permissible exposure with the SNIC1 and were not measured during this evaluation.




Report No: AT72133597-4P0                                        TÜV SÜD America, Inc.                                                      Page 9


  Models: SNIC1                          FCC ID: SK9SNIC1                          IC: 864G-SNIC1

7.1.3   Summation of MPE Ratios – Simultaneous Transmissions
Performed by: Ryan McGann

This device contains multiple transmitters which can operate simultaneously; therefore, the
maximum RF exposure is determined by the summation of MPE ratios. The limit is such that the
summation of MPE ratios is ≤ 1.0.

                                Table 7.1.3-1: Summation of MPE Ratios – FCC
                                                              Scenario 1
                                 900MHz ISM                       x
                                 2.4GHz ISM                       x
                                 900 MHz ISM
                                 (RN-ERT Gateway STAR)             x
                                 900MHz ISM                       0.0908
                                 MPE Ratio
                                 2.4GHz ISM                       0.0007
                                 MPE Ratio
                                 900 MHz ISM                      0.2951
                                 (RN-ERT Gateway STAR)
                                 MPE Ratio
                                 MPE Ratio Summation:             0.3865

                            Table 7.1.3-2: Summation of MPE Ratios – ISED Canada
                                                              Scenario 1
                                 900MHz ISM                       x
                                 2.4GHz ISM                       x
                                 900 MHz ISM
                                 (RN-ERT Gateway STAR)             x
                                 900MHz ISM                       0.1983
                                 MPE Ratio
                                 2.4GHz ISM                       0.0012
                                 MPE Ratio
                                 900 MHz ISM                      0.6506
                                 (RN-ERT Gateway STAR)
                                 MPE Ratio
                                 MPE Ratio Summation:             0.8501




Report No: AT72133597-4P0                      TÜV SÜD America, Inc.                        Page 10


    Models: SNIC1                   FCC ID: SK9SNIC1                        IC: 864G-SNIC1

8    ESTIMATION OF MEASUREMENT UNCERTAINTY

The expanded laboratory measurement uncertainty figures (ULab) provided below correspond to
an expansion factor (coverage factor) k = 1.96 which provide confidence levels of 95%.

                                 Parameter                               Ulab
           Electric Field                                               39.12%


9    CONCLUSION

In the opinion of TÜV SÜD America, Inc. the SNIC1, manufactured by Itron, Inc. meets the
requirements of FCC Part 1 subpart I and Innovation, Science, and Economic Development
Canada’s Radio Standards Specification RSS-102 for the tests documented in this test report.




                                    END REPORT




Report No: AT72133597-4P0                TÜV SÜD America, Inc.                         Page 11



Document Created: 2018-02-26 11:20:50
Document Modified: 2018-02-26 11:20:50

© 2024 FCC.report