RF EXPOSURE

FCC ID: SK9AMI-2

RF Exposure Info

Download: PDF
FCCID_726006

              FCC Part 15.247/15.249
              Transmitter Certification
                    Class II Permissive Change

                       Composite Device


                           Test Report
                        FCC ID: SK9AMI-2

                FCC Rule Part: 15.247/15.249

           ACS Report Number: 06-0241-15C

       Manufacturer: Itron Electricity Metering Inc.
         Trade Name: CENTRON Open Way
                  Model(s): CVSOR




                         RF Exposure




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: CVSOR                             Advanced Compliance Solutions                     FCC ID: SK9AMI-2


General Information:
Applicant:                  Itron Electricity Metering Inc.
ACS Project:                06-0241
FCC ID:                     SK9AMI-2
Device Category:            Mobile
Environment:                General Population/Uncontrolled Exposure
Exposure Conditions:        Greater than 20 centimeters

Purpose:

The Itron Electricity Metering Inc. model CVSOR was evaluated in a configuration with multiple
simultaneously transmitting radios. This configuration consisted of an Enfora L.P. GPRS modem module
GSM0108 integrated into the Itron electricity meter CVSOR. The Enfora L.P. GPRS modem module
GSM0108 was previously certified under FCC ID: MIVGSM0108, IC: 4160A-GSM0108.

Technical Information:
                                             2.4GHz Zigbee        2.4GHz Zigbee            GPRS Modem
Radio                  900 MHz LAN
                                            (Register Board)    (Cell Relay Board)           Module
                           single-band                          surface mount omni-
Antenna Type                  patch
                                             single-band slot
                                                                     directional
                                                                                           dual-band patch
                                                                                            GSM850: 0dBi
Antenna Gain                  3dBi                4dBi                  3dBi
                                                                                            GSM1900: 3dBi
Conducted                                                                                GSM850: 32.4dBm
                           19.40dBm             -6.7dBm              -12.99dBm
Power                                                                                    GSM1900: 29.8dBm
                                                                                          GSM850: 1.738W
Max. EIRP                   0.174W              0.0005W               0.0001W
                                                                                          GSM1900: 1.905W
                                                                                          GSM850: 1.059W
Max. ERP                    0.106W              0.0003W              0.00006W
                                                                                          GSM1900: 1.161W

MPE Calculation:
        Calculated Conducted Power (15.249)
        For the purpose of determining Power Density for the 2.4GHz Zigbee radios, the conducted RF
        power must first be calculated.

        The power was calculated using the following equation:

        P = (E ∗ d )
                       2

                           30 ∗ G
        Where: G = Numeric Gain of the transmitting antenna with reference to an isotropic radiator
               d = The distance in meters from which the field strength was measured
               E = The measured maximum fundamental field strength in V/m




                5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: CVSOR                        Advanced Compliance Solutions                         FCC ID: SK9AMI-2


    Table 1: Maximum Fundamental Field Strength – 2.4GHz Zigbee Radio Register Board
                              Uncorrected                                            Corrected
              Frequency                       Antenna           Total Correction
                                Reading                                               Reading
                (MHz)                       Polarity (H/V)        Factor (dB)
                               (dBµV/m)                                              (dBµV/m)
                   2480          91.96              H                 0.53              92.49

               Table 2: Peak Output Power– 2.4GHz Zigbee Radio Register Board
        Frequency         Numeric Gain      Distance         Max. Fund. Field      Output Power
          (MHz)                                (m)            Strength (V/m)          (dBm)
            2480             2.51               3                 0.04                  -6.7

    Table 3: Maximum Fundamental Field Strength – 2.4GHz Zigbee Radio Cell Relay Board
                              Uncorrected                                            Corrected
              Frequency                       Antenna           Total Correction
                                Reading                                               Reading
                (MHz)                       Polarity (H/V)        Factor (dB)
                               (dBµV/m)                                              (dBµV/m)
                   2480          84.71              H                 0.53              85.24

               Table 4: Peak Output Power– 2.4GHz Zigbee Radio Cell Relay Board
        Frequency         Numeric Gain      Distance         Max. Fund. Field      Output Power
          (MHz)                                (m)            Strength (V/m)          (dBm)
            2480             2.00               3                 0.02                 -12.99

      Power Density
      The Power Density (mW/cm2) is calculated as follows:

             PG
      S=
            4πR 2
      Where:
      S = power density (in appropriate units, e.g. mW/cm2)
      P = power input to the antenna (in appropriate units, e.g., mW)
      G = power gain of the antenna in the direction of interest relative to an isotropic radiator
      R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                               MPE Calculator for Mobile Equipment
                      Limits for General Population/Uncontrolled Exposure*
 Transmit    Radio          Power         Radio     Antenna Antenna
                                                                       Distance Power Density
Frequency    Power      Density Limit     Power      Gain Gain (mW
                                                                         (cm)    (mW/cm^2)
  (MHz)      (dBm)       (mW/Cm2)         (mW)       (dBi)       eq.)
  902.25      19.4           0.60         87.10         3       1.995      20      0.035
   2480       -6.7           1.00          0.21         4       2.512      20      0.000
   2480      -12.99          1.00          0.05         3       1.995      20      0.000
   824        32.4           0.55        1737.80        0       1.000      20      0.346
   1850        30            1.00        1000.00        3       1.995      20      0.397




               5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: CVSOR                       Advanced Compliance Solutions                          FCC ID: SK9AMI-2


       Summation of Power Densities – Simultaneous Transmissions
       This device contains multiple transmitters which can operate simultaneously and therefore the
       maximum RF exposure is determined by the summation of power densities. The maximum
       power density as calculated by a summation of power densities for each transmitter is as follows:

       GPRS Modem Operating in the 800MHz Cellular Band:

       900MHz LAN:              0.035 (mW/cm^2)
       2.4GHz Zigbee:           0.000 (mW/cm^2) *Includes both 2.4GHz Radios
       GSM 850 (GPRS):          0.346 (mW/cm^2)
       TOTAL:                   0.381 (mW/cm^2)

       GPRS Modem Operating in the 1900MHz PCS Band:

       900MHz LAN:              0.035 (mW/cm^2)
       2.4GHz Zigbee:           0.000 (mW/cm^2) *Includes both 2.4GHz Radios
       GSM 1900 (GPRS):         0.397 (mW/cm^2)
       TOTAL:                   0.432 (mW/cm^2)


Installation Guidelines:
The installation manual contains text advising how to install the equipment to maintain compliance with
the FCC RF exposure requirements.


Conclusion:
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




               5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598



Document Created: 2006-11-03 10:36:10
Document Modified: 2006-11-03 10:36:10

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC