            TEK 561 TEKELEK LPG LEVEL MONITOR
                                                                                      3 FITTING TRANSMITTER

•         The Tekelek LPG Level Monitor                                                       This unit is only to be fitted
          measures the level of usable LPG                                                    to a tank with a compatible
          in your tank in 10 graduations of                                                   Rochester twin-site gauge
                                                                                              head.
          the tank height.
                                                                                      •       Check that the existing tank
•         We give a full 3 year warranty subject to normal conditions.                        gauge is of the same design
          Supplied with long life no service lithium battery The warranty                     as the one on the end of the
          becomes invalid if the sealed unit is opened.                                       cable from the TEKELEK
                                                                                              LPG Monitor. Then check
•         Suitable for use in tanks for the storage of LPG, Propane or                        and note the reading on the existing gauge and remove the gauge
                                                                                              display only – This is held in place with two securing screws. Dispose of
          Butane. Check with the manufacturer and/or supplier before                          the old gauge according to local environmental guidelines.
          using with any other fluids.
                                                                                      •       Fit the new gauge to the tank using the same screws. And check that
•         The TEKELEK LPG will fit easily to most standard storage                            the level on the gauge is the same as before.
          tanks using a standard Rochester type gauge head.
                                                                                      • Locate the transmitter on a wall (with screws) or drain pipe (with cable
                                                                                        ties) in a position that is unlikely to be subject to impact causing damage
•         400 meters ‘line of sight’ transmission range. Please note that
                                                                                        to the equipment.
          the radio transmission distance will be reduced by the proximity
          of metal, e.g., steel in buildings, metal domestic appliances etc           • Tidy up the cable so as not to cause an obstruction.
          that are effectively between the transmitter and receiver.
                                                                                  •           Do not fit the unit to the LPG feed pipe from the tank. The unit may only
•         -30°C to 45°C operating temperature range. Please note that                         be fitted to a non LPG carrying pipe.
          the battery operating lifetime may be reduced at higher
          temperatures                                                                        The TEKELEK LPG Level Monitor is now fully installed and signals
                                                                                              should be received every hour. After initial installation it may take one
                                                                                              hour for the correct level indication to be displayed on the receiver.
        We reserve the right to change or improve the performance and
        specification.                                                                        NOTE:
                                                                                              In the event of a power failure or if the receiver is switched off or moved
  INSTALLATION INSTRUCTIONS                                                                   to a new socket:
     First, Read the essential health and safety notice.                                      When power returns again or unit is switched on, the receiver display
•    Tools required: Star/Philips head screwdriver                                            will show the top bar flashing. There is no need to repeat the
                                                                                              matching instruction. The top bar will continue to flash for 2 minutes,
  1 SETTING RECEIVER                                                                          after which time the display will show the last reading, whilst the unique
                                                                                              signal is located. This may take up to one hour.
    •     The multi switches are located in a recess at the back of the
          receiver above the pins. If the tank is a vertical tank then set            4 ESSENTIAL HEALTH AND SAFETY NOTICE
          switch 1 on (up), if it’s horizontal set switch 1 off (down)
                                                                                          Manufactured by Tekelek Europe LTD,
          Your TEKELEK LPG receiver is now                                                Shannon, Ireland
          programmed to your tank height.                                                 Part Nr: 17-5497 (EU), 17-5495 (USA)

    2 MATCHING RECEIVER AND
      TRANSMITTER                                                                                    II 2 G Ex ib IIA                Tamb: -30 to +45°C
          You should match the receiver with the                                                       0891                         TRAC09ATEX21221X
          transmitter so that the system code is
          unique to your tank.                                                            •       The Battery is not replaceable
          You only need to do this once.                                                  •       Do not attempt to open the unit in a potentially explosive atmosphere
                                                                                          •       Periodically check that the unit is intact and securely fastened to the tank.
•         Plug receiver into a suitable and                                               •       Check with the manufacturer on the chemical compatibility prior to use.
          convenient electrical socket and switch                                         •       Do not attempt to repair this equipment. It must be returned to the
                                                                                                  manufacturer for repair.
          on. The display screen on the front of
                                                                                          •       Warning! Electrostatic Hazard! Clean only with an antistatic cloth
          the receiver will show a flashing top bar
          as shown in diagram. This indicates                                                       FCC ID:S6T-561
          that the receiver is awaiting a unique                                          This device complies with Part 15 of the FCC Rules. Operation is subject to the
          code. The bar will continue to flash for 2                                      following two conditions: (1) This device may not cause harmful interference,
          minutes during which time you can                                               and (2) This device must accept any interference received, including
          match the transmitter to the receiver.                                          interference that may cause undesired operation.

•         Hold the transmitter against the
                                                                                      Declaration:
          receiver right hand side, as shown,                                         This apparatus is designed to:- Not to give rise to physical injury or other
          so that the black dots are touching                                         harm due to contact. Not to produce excessive surface temperatures, infra-
          each other (important!) for about 20                                        red, electromagnetic, ionising radiation. To have no non-electrical dangers,
          seconds to allow unique code to be                                          when used in accordance with these user and installation instructions
          transferred. Bars will increase up the
          display screen. When all 10 bars are                                        Warning:
          shown they will flash to indicate that                                      If the equipment is likely to come in to contact with aggressive substances,
          the unique code is transferred.                                             then it is the responsibility of the user to take suitable precautions that
                                                                                      prevent it from being adversely affected, thus ensuring that the type of
                                                                                      protection is not compromised. Aggressive substances; - e.g. acidic liquids
                                                                                      or gases that may attack metals, or solvents that may affect polymeric
                                                                                      materials.

                                                                                      Note:
                                                                                      No modifications or additions are allowed to this equipment as to do so will
                                                                                      void the user’s authority to operate the equipment.


                                                                                      Complies with EN60079-0:2006 and EN60079-11:2007



                                                                              1                                                                                     9-5452-01


TEKELEK LPG DISPLAY
  NORMAL MESSAGES




          Full            Early Warning          Almost empty


  Flashing triangle, no bars
  No radio signal
  (after waiting for two hours)

- check for correct matching procedure
- location of receiver to transmitter (try
  repositioning receiver)
- moisture ingress due to seal damage
- exhausted battery
                                                       No Signal


  Steady triangle.
  Low battery

- The battery in the transmitter is getting
  low.
- The battery is not replaceable – The unit
  must be returned to the factory for
  replacement – The normal service life of
  the battery is 15 years.

                                                      Low battery
CHANGING BATTERY
Though the lithium battery will have a very long service life, it will
eventually become exhausted and need changing.

Do not attempt to replace the battery – simply remove the unit
from the tank and return the complete unit to the factory for
replacement. The battery can only be replaced by the
manufacturer.


For support contact: support@tekelek.ie