08._WL865E4-P_2262ERM.004_EMC_FCC15B

FCC ID: RI7WL865E4

Test Report

Download: PDF
FCCID_4491000

DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




                                                      FCC LISTED, REGISTRATION
                                                      NUMBER: 2764.01                    Test report No:
                                                      ISED LISTED REGISTRATION           2262ERM.004
                                                      NUMBER: 23595-1



                                                Test report
         FCC Rules and Regulations CFR 47, Part 15, Subpart B (10-1-18 Edition)
                                         &
                       ICES-003 ISSUE 6 – Update April (2017)


          Identification of item tested
                                                          Wireless Module


          Trademark                                       Telit


          Model and /or type reference                    WL865E4-P

          Other identification of the product             FCC: RI7WL865E4
                                                          IC ID: 5131A-WL865E4

          Features                                        WiFi 802.11 a/b/g/n @2.4 GHz and @5 GHz + Bluetooth
                                                          Low Energy

          Manufacturer                                    Telit Communications S.p.A.
                                                          Via Stazione di Prosecco 5/B
                                                          34010 Sgonico
                                                          Trieste-Italy
          Test method requested, standard                 FCC Rules and Regulations CFR 47, Part 15, Subpart B
                                                          (10-1-18 Edition)
                                                          ICES-003 ISSUE 6 – Update April (2017)

          Summary                                         IN COMPLIANCE


          Approved by (name / position & signature)       Domingo Galvez                        Digitally signed by Domingo
                                                                                                Galvez
                                                          EMC&RF Lab Manager                    DN: cn=Domingo Galvez,
                                                                                                o=DEKRA Certification Inc.,
                                                                                                ou=Regulatory Lab,
                                                                                                email=dgalvez@dekra.com,
                                                                                                c=US
                                                                                                Date: 2019.06.28 12:26:25
                                                                                                -04'00'

          Date of issue                                   2019-06-20

          Report template No                              FDT08_21




Report No: 2262ERM.004                                                                                                 2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




                                                                   Index
   Competences and guarantees .................................................................................................... 3
   General conditions ...................................................................................................................... 3
   Uncertainty ................................................................................................................................. 3
   Data provided by the client.......................................................................................................... 4
   Usage of samples ....................................................................................................................... 4
   Test sample description .............................................................................................................. 5
   Identification of the client............................................................................................................. 6
   Testing period and place ............................................................................................................. 6
   Document history ........................................................................................................................ 6
   Environmental conditions ............................................................................................................ 7
   Remarks and comments ............................................................................................................. 7
   Testing verdicts........................................................................................................................... 8
   List of equipment used during the test......................................................................................... 8
   Appendix A: Test results ............................................................................................................. 9




Report No: 2262ERM.004                                               Page 2 of 16                                                            2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Competences and guarantees
   DEKRA Certification Inc. is a testing laboratory accredited by A2LA (The American Association for Laboratory
   Accreditation), to perform the tests indicated in the Certificate 2764.01
   DEKRA Certification Inc. is a testing laboratory competent to carry out the tests described in this report.
   In order to assure the traceability to other national and international laboratories, DEKRA Certification Inc. has a
   calibration and maintenance program for its measurement equipment.
   DEKRA Certification Inc. guarantees the reliability of the data presented in this report, which is the result of the
   measurements and the tests performed to the item under test on the date and under the conditions stated on
   the report and, it is based on the knowledge and technical facilities available at DEKRA Certification at the time
   of performance of the test.
   DEKRA Certification Inc. is liable to the client for the maintenance of the confidentiality of all information related
   to the item under test and the results of the test.
   The results presented in this Test Report apply only to the particular item under test established in this
   document.
   IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
   except in full, without the previous written permission of DEKRA Certification Inc.


General conditions
       1. This report is only referred to the item that has undergone the test.
       2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
          or competent Authorities.
       3. This document is only valid if complete; no partial reproduction can be made without previous written
          permission of DEKRA Certification Inc.
       4. This test report cannot be used partially or in full for publicity and/or promotional purposes without
          previous written permission of DEKRA Certification Inc. and the Accreditation Bodies.


Uncertainty
   Uncertainty (factor k=2) was calculated according to the DEKRA Certification internal document PODT000.


                                                       Frequency (MHz) U(k=2)       Units
                              Conducted emission          0,009 - 30    2.69        dB
                                                            30-180      3.82        dB
                                                          180-1000      2.61        dB
                              Radiated emission
                                                         1000-18000     2.92        dB
                                                        18000-40000     2.15        dB




Report No: 2262ERM.004                                Page 3 of 16                                            2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Data provided by the client
   WiFi / BLE Module
   DEKRA declines any responsibility with respect to the information provided by the client and that may affect the
   validity of results.


Usage of samples
   Samples undergoing test have been selected by: The client.
   Sample S/01 is composed of the following elements:

                                                                                                  Date of
     Control Nº                 Description                 Model              Serial Nº
                                                                                                 reception
                            WL865E-P on debug
       2262.003                                         WL865E-P           00217E249E74           05/07/2019
                                 board

   Following accessories were for enable EUT to stay operation during testing

                                                                                                  Date of
     Control Nº                 Description                 Model              Serial Nº
                                                                                                 reception

                            USB cable (A to micro)
       2262.005                                              -                    -               05/07/2019
                                    6fT
                                  Antenna            T-AT9552           1RR0100174TLB
       2323.03                                                                                    05/07/2019
                                  Antenna            T-AT9552           1RR0100174TLB
       2323.04                                                                                    05/07/2019


   Sample S/01 was used in following testing: Radiated Emission




Report No: 2262ERM.004                                   Page 4 of 16                                    2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Test sample description
Ports………………………………. :                                                                                                  Cable

                                                       Port name and description                Specified        Attached during      Shielded
                                                                                                 length                test
                                                                                                   [m]

                                                                      USB                            0.5




Supplementary information to the
                                                       No Data Provided
ports………………………………. :
Rated power supply .................... :                                                                       Reference poles
                                                       Voltage and Frequency
                                                                                                L1         L2    L3            N        PE

                                                            AC: 230Vac / 50Hz.
                                                            AC:
                                                            DC:3.3 V
                                                            DC:
Rated Power ............................... :          No Data Provided
Clock frequencies ....................... :            40 MHz
Other parameters ........................ :            No Data Provided
Software version ......................... :           M0G.000002
Hardware version ........................ :            HW 0.0
Dimensions in cm (L x W x D) .... :                    2.44 x 0.29 x 2.44
Mounting position ........................ :                 Table top equipment
                                                             Wall/Ceiling mounted equipment
                                                             Floor standing equipment
                                                             Hand-held equipment
                                                             Other: all the above depending on the host application system
Modules/parts ............................. :          Module/parts of test item                                 Type         Manufacturer

                                                       WL865E4-P                                           Interface board    Telit

Accessories (not part of the test                      Description                  Type                                      Manufacturer
item) ............................................ :
                                                       WL865E4-P EVB IF             Interface board                           Telit

                                                       Micro USB cable              Cable

                                                       T-AT9552 external            Antenna                                   ATEL-
                                                       antenna                                                                ANTENNAS

Documents as provided by the                           Description                  File name                                 Issue date
applicant ...................................... :
                                                       Equipment                    FDT30_14_FCC_TELIT_WL865E4-               2019-02-04
                                                       declaration data             P_rev0
Report No: 2262ERM.004                                               Page 5 of 16                                                  2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America



                                                  Copy of marking plate:




Identification of the client
Telit Communication S.p.A.
Via Stazione di Prosecco 5/b
34010 SGONICO TRIESTE - ITALY


Testing period and place
      Test Location          DEKRA Certification, Inc
       Date (start)          2019-05-08
       Date (finish)         2019-05-08


Document history
  Report number                Date                                        Description
   2262ERM.004              2019-05-13     First release




Report No: 2262ERM.004                                     Page 6 of 16                  2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Environmental conditions

   In the control chamber, the following limits were not exceeded during the test:


                                                      Min. = 15 ºC
             Temperature
                                                      Max. = 35 ºC
                                                      Min. = 30 %
             Relative humidity
                                                      Max. = 75 %
                                                      Min. = 860 mbar
             Air pressure
                                                      Max. = 1060 mbar


   In the semi anechoic chamber, the following limits were not exceeded during the test.


                                                      Min. = 15 ºC
             Temperature
                                                      Max. = 35 ºC
                                                      Min. = 30 %
             Relative humidity
                                                      Max. = 75 %
                                                      Min. = 860 mbar
             Air pressure
                                                      Max. = 1060 mbar


   In the chamber for conducted measurements, the following limits were not exceeded during the test:


             Temperature                              Min. = 15 ºC
                                                      Max. = 35 ºC
             Relative humidity                        Min. = 30 %
                                                      Max. = 60 %
             Air pressure                             Min. = 860 mbar
                                                      Max. = 1060 mbar


Remarks and comments
The tests have been performed by the technical personnel: Koji Nishimoto & Poojita Bhattu




Report No: 2262ERM.004                               Page 7 of 16                                       2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Testing verdicts


                            Not applicable :                                          N/A

                            Pass    :                                                 P

                            Fail    :                                                 F

                            Not measured :                                            N/M



Summary
                                                        Emission Test
 Report                                    Requirement – Test case
                                                                                              Verdict       Remark
 Section
    A.1.       Radiated emission electromagnetic field test (30 MHz – 1000 MHz)                     P          N/A
    A.1.       Radiated emission electromagnetic field test (1 GHz – 18 GHz)                        P        Refer 1
    A1.        Radiated emission electromagnetic field test (18 GHz – 40 GHz)                       --       Refer 1
     -.        Conducted emission test (150 kHz to 30 MHz)                                      N/A          Refer 2
Supplementary information and remarks:
      1)   As per standard 47 CFR §15.33 due to the highest frequency generated or used in the device is above 1000MHz
           the upper frequency of measurement range is up to 5th harmonic of the highest frequency or 40GHz, whichever is
           lower.
      2)   DUT is a module and not the final product.




List of equipment used during the test
 CONTROL                                                                                 LAST                 NEXT
                       DESCRIPTION             MANUFACTURER               MODEL
 NUMBER                                                                               CALIBRATION          CALIBRATION
                                                   BONN                  BLNA 0360-
     0980                   Preamplifier                                                    2017/05            2019/05
                                                ELEKTRONIK                  01N
                                                   BONN
     0981                   Preamplifier                             BLMA 0118-2A           2018/10            2020/10
                                                ELEKTRONIK
     0982                                          BONN
                            Preamplifier                             BLMA1840-1M            2018/10            2020/10
                                                ELEKTRONIK
                    EMC measurement              ROHDE &
     1017                                                            EMC32 V9.01              ---                 ---
                        software                 SCHWARZ
     1039                                        ROHDE &
                       Signal Analyser                                     FSV40            2018/10            2020/10
                                                 SCHWARZ
     1055              Horn Antenna            ETS LINDGREN                3116C            2016/12            2019/12
     1058              Horn Antenna            ETS LINDGREN                 3115            2017/03            2020/03
     1065            Biconilog Antenna         ETS LINDGREN                3142E            2017/03            2020/03




Report No: 2262ERM.004                                    Page 8 of 16                                           2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




     Appendix A: Test results




Report No: 2262ERM.004      Page 9 of 16   2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




                                      Appendix A Content

   DESCRIPTION OF THE OPERATION MODES ........................................................................ 11
   A.1.RADIATED EMISSION. ELECTROMAGNETIC FIELD TEST ............................................. 12




Report No: 2262ERM.004                               Page 10 of 16                                           2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




DESCRIPTION OF THE OPERATION MODES
The operation modes described in this paragraph constitute a functionality of the sample under test for itself.
Every operation mode takes failure criteria for the immunity test that they were applying to it and a monitoring
to guarantee performance of the same ones.
The operation modes used by the samples to which the present report refers, are shown in the following table:


          OPERATION                                       DESCRIPTION
            MODE
                            EUT ON. Power supply 3.3 Vdc
                               •   Idle mode
              OM#01*           •   No TX/RX Blue tooth
                               •   No TX/RX Wifi 2.4GHz
                               •   No TX/RX Wifi 5GHz
         *Worst configurations detected




Report No: 2262ERM.004                              Page 11 of 16                                          2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




A.1.RADIATED EMISSION. ELECTROMAGNETIC FIELD TEST
                                                           FCC CFR 47, Part 15, Subpart B (10-1-18 Edition), Secs. 15.109
                            Product standard:
                                                           & ICES-003 Issue 6 – Update April (2017)
    LIMITS:
                                                           FCC CFR 47, Part 15, Subpart B (10-1-18 Edition), Secs. 15.109
                               Test standard:
                                                           & ICES-003 Issue 6 – Update April (2017); ANSI C63.4 (2014)

Limits of interference Class B
The applied limit for radiated emissions, 3 m distance, according with the requirements of FCC Rules and
Regulations 47 CFR Part 15, Subpart B (10-01-18 Edition), Secs. 15.109 & ICES-003 Issue 6 – Update April
(2017) in the frequency range 30 MHz to 40 GHz for class B equipment.

                                                Frequency range                       QP Limit for 3 m
                                                     (MHz)                         (V/m)        (dBV/m)
                                                    30 to 88                         100            40
                                                   88 to 216                         150           43.5
                                                   216 to 960                        200            46
                                                   Above 960                         500            54

                                    Frequency range               AVG Limit for 3 m              PK Limit for 3 m (1)
                                         (MHz)                  (V/m)     (dBV/m)                  (dBV/m)
                                      Above 1000                  500          54                        74
                            Frequencies above 1 GHz, the limit on peak radio frequency emissions is 20 dB above the maximum permitted
                            average emission limit applicable to the equipment under test, as per §15.35(b




                TEST SETUP


All radiated tests were performed in a semi-anechoic chamber. The measurement antenna is situated at a
distance of 3 m for the frequency range 30-1000 MHz (Bilog antenna) and at a distance of 1m for the frequency
range 1-40 GHz (1 GHz-18 GHz and 18 GHz-40 GHz Double ridge horn antennas).
For radiated emissions in the range 1-40 GHz that is performed at a distance closer than the specified distance,
an inverse proportionality factor of 20 dB per decade is used to normalize the measured data for determining
compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation
and orientation was varied to find the maximum radiated emission. It was also rotated 360º and the antenna
height was varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization.
The field strength is calculated by adding correction factor to the measured level from the spectrum analyzer.
This correction factor includes antenna factor, cable loss and pre-amplifiers gain.




Report No: 2262ERM.004                                                  Page 12 of 16                                                   2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




          TEST SETUP (Cont.)




           TESTED SAMPLES:                                                   S/01
   TESTED OPERATION MODES:                                               OM#01
                                          CRmmnnxx: CR, Radiation Condition; mm: Sample number; nn:
             TEST RESULTS:
                                          Operation mode.,xx:Range,




            CRmmnnxx                             Description                              Result
           CR0101LR         Range: 30 MHz - 1000 MHz Horizontal Polarization                P

           CR0101LR         Range: 30 MHz - 1000 MHz Vertical Polarization                  P

           CR0101HR1        Range: 1-18 GHz Horizontal Polarization                         P

           CR0101HR1        Range: 1-18 GHz Vertical Polarization                           P

           CR0101HR2        Range: 18-26 GHz Horizontal Polarization                        P

           CR0101HR2        Range: 18-26 GHz Vertical Polarization                          P




Report No: 2262ERM.004                               Page 13 of 16                                    2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Radiated Emission. CR0101LR


  Project:                              02262ERM009
  Company:                              Telit
  Sample:                               S/01
  Operation mode:                       OM#01
  Description:                          EUT ON. Standalone basis. Power supply: 3.3Vdc. Both polarizations
                 Level in dBµV/m




                                                   Final_Result
                                   Frequency      MaxPeak     QuasiPeak    Pol   Azimuth
                                     (MHz)        (dBµV/m)    (dBµV/m)            (deg)
                                      30.097000       25.84        13.65   H        -92.0
                                      64.095500       16.26         3.96   V       -180.0
                                      78.015000       17.14         4.31   H       -200.0
                                     345.298500       27.20        15.04   H         93.0
                                     399.667000       29.93        17.26   V       -180.0
                                     598.856500       34.09        22.31   V        169.0




Report No: 2262ERM.004                                 Page 14 of 16                                         2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America


Radiated Emission. CR0101HR1



  Project:                          02262ERM009
  Company:                          Telit
  Sample:                           S/01
  Operation mode:                   OM#01
  Description:                      EUT ON. Standalone basis. Power supply: 3.3Vdc. Both
                                    polarizations
                 Level in dBµV/m




                                                   Final_Result
                                   Frequency       MaxPeak      Average    Pol   Azimuth
                                      (MHz)        (dBµV/m)    (dBµV/m)           (deg)
                                     6455.785714        45.1        31.7   V        180.0
                                    11066.914286        51.9        37.8   V       -176.0
                                    13275.700000        58.2        44.8   V       -107.0
                                    17212.171429        63.1        49.2   V       -159.0




Report No: 2262ERM.004                                Page 15 of 16                         2019-06-20


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America


Radiated Emission. CR0101HR2



  Project:                         02262ERM009
  Company:                         Telit
  Sample:                          S/01
  Operation mode:                  OM#01
  Description:                     EUT ON. Standalone basis. Power supply: 3.3Vdc. Both
                                   polarizations
                 Level in dBµV/m




          No spurious observed in 18-40GHz




Report No: 2262ERM.004                            Page 16 of 16                           2019-06-20



Document Created: 2019-06-28 12:26:25
Document Modified: 2019-06-28 12:26:25

© 2024 FCC.report