Test Report_JBP

FCC ID: R9C-CPH1941

Test Report

Download: PDF
FCCID_4496155

                                                        Report No.: BTL-FCCE-1-1909C106




                  FCC EMC Test Report
Project No.        :   1909C106
Equipment          :   Mobile Phone
Brand Name         :   OPPO
Test Model         :   CPH1941
Series Model       :   N/A
Applicant          :   GuangDong Oppo Mobile Telecommunications Corp., Ltd.
Address            :   NO. 18 HaiBin Road, WuSha village, Chang An Town, DongGuan
                       City,Guangdong,China.
Manufacturer       :   GuangDong Oppo Mobile Telecommunications Corp., Ltd.
Address            :   NO. 18 HaiBin Road, WuSha village, Chang An Town, DongGuan
                       City,Guangdong,China.
Factory            :   GuangDong Oppo Mobile Telecommunications Corp., Ltd.
                   :   NO. 18 HaiBin Road, WuSha village, Chang An Town, DongGuan
Address
                       City,Guangdong,China.
Date of Receipt    :   Sep. 19, 2019
Date of Test       :   Sep. 21, 2019 ~ Sep. 30, 2019
Issued Date        :   Oct. 24, 2019
Report Version     :   R00
Test Sample        :   Engineering Sample No.: DG2019091946
Standard(s)        :   FCC Part 15, Subpart B


The above equipment has been tested and found compliance with the requirement of
the relative standards by BTL Inc.




Prepared by : Kang Zhang



Approved by : Kevin Li




Add: No.3, Jinshagang 1st Road, Shixia, Dalang Town,Dongguan, Guangdong, China.
Tel: +86-769-8318-3000
Web: www.newbtl.com
                                     Page 1 of 39


                                                                          Report No.: BTL-FCCE-1-1909C106



Declaration
BTL represents to the client that testing is done in accordance with standard procedures as applicable and
that test instruments used has been calibrated with standards traceable to international standard(s) and/or
national standard(s).
BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to
ensure that additional production units of this model are manufactured with the identical electrical and
mechanical components. BTL shall have no liability for any declarations, inferences or generalizations
drawn by the client or others from BTL issued reports.
The report must not be used by the client to claim product certification, approval, or endorsement by NIST,
A2LA, or any agency of the U.S. Government.
This report is the confidential property of the client. As a mutual protection to the clients, the public and
ourselves, the test report shall not be reproduced, except in full, without our written approval.
BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and
accredited by the conformity assessment authorities listed in this test report.
BTL is not responsible for the sampling stage, so the results only apply to the sample as received.
The information, data and test plan are provided by manufacturer which may affect the validity of results, so
it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied
standards and in all the possible configurations as representative of its intended use.
Limitation
For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this
test report is (are) included in the conformity assessment authorities acceptance respective.
Please note that the measurement uncertainty is provided for informational purpose only and are not use in
determining the Pass/Fail results.




                                                Page 2 of 39


                                               Report No.: BTL-FCCE-1-1909C106




                      Table of Contents                            Page

REPORT ISSUED HISTORY                                                 4
1 . SUMMARY OF TEST RESULTS                                           5
  1.1 TEST FACILITY                                                   6
  1.2 MEASUREMENT UNCERTAINTY                                         6
  1.3 TEST ENVIRONMENT CONDITIONS                                     6
2 . GENERAL INFORMATION                                               7
  2.1 GENERAL DESCRIPTION OF EUT                                      7
  2.2 DESCRIPTION OF TEST MODES                                       8
  2.3 EUT OPERATING CONDITIONS                                       10
  2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10
  2.5 DESCRIPTION OF SUPPORT UNITS                                   12
3 . EMC EMISSION TEST                                                13
  3.1 AC POWER LINE CONDUCTED EMISSIONS TEST                         13
     3.1.2 MEASUREMENT INSTRUMENTS LIST                              13
     3.1.3 TEST PROCEDURE                                            14
     3.1.4 DEVIATION FROM TEST STANDARD                              14
     3.1.5 TEST SETUP                                                14
     3.1.6 TEST RESULTS                                              14
  3.2 RADIATED EMISSIONS 30 MHZ TO 1 GHZ                             17
     3.2.1 LIMIT                                                     17
     3.2.2 MEASUREMENT INSTRUMENTS LIST                              17
     3.2.3 TEST PROCEDURE                                            18
     3.2.4 DEVIATION FROM TEST STANDARD                              18
     3.2.5 TEST SETUP                                                18
     3.2.6 TEST RESULTS                                              18
  3.3 RADIATED EMISSIONS ABOVE 1 GHZ                                 21
     3.3.1 LIMIT                                                     21
     3.3.2 MEASUREMENT INSTRUMENTS LIST                              22
     3.3.3 TEST PROCEDURE                                            23
     3.3.4 DEVIATION FROM TEST STANDARD                              23
     3.3.5 TEST SETUP                                                24
     3.3.6 TEST RESULTS                                              25
4 . EUT TEST PHOTO                                                   34




                              Page 3 of 39


                                             Report No.: BTL-FCCE-1-1909C106



                 REPORT ISSUED HISTORY

Report Version              Description                     Issued Date
    R00                    Original Issue.                  Oct. 24, 2019




                      Page 4 of 39


                                                 Report No.: BTL-FCCE-1-1909C106




1. SUMMARY OF TEST RESULTS
                              Emission

     Ref Standard(s)                 Test Item                     Result

                        AC Power Line Conducted Emissions          PASS

    ANSI C63.4-2014     Radiated Emissions 30 MHz to 1 GHz         PASS

                         Radiated Emissions Above 1 GHz            PASS




                             Page 5 of 39


                                                                   Report No.: BTL-FCCE-1-1909C106




1.1 TEST FACILITY
The test facilities used to collect the test data in this report at the location of No.3, Jinshagang
1st Road, Shixia, Dalang Town, Dongguan, Guangdong, China.
BTL's Test Firm Registration Number for FCC: 357015
BTL's Designation Number for FCC: CN1240

1.2 MEASUREMENT UNCERTAINTY
ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with
the emissions test results be included in the report. The measurement uncertainties given
below are based on a 95% confidence level (based on a coverage factor (k=2))
The BTL measurement uncertainty as below table:

A. AC power line conducted emissions test:

          Test Site       Method          Measurement Frequency Range              U,(dB)
          DG-C02          CISPR                  150 kHz ~ 30MHz                    2.32

B. Radiated emissions test:

                                                                           Ant.
          Test Site       Method      Measurement Frequency Range               U,(dB)
                                                                           H/V
                                             30MHz ~ 200MHz                 V    3.76

          DG-CB08                            30MHz ~ 200MHz                  H      3.56
                          CISPR
            (3m)                            200MHz ~ 1,000MHz                V      4.00
                                            200MHz ~ 1,000MHz                H      3.90


          Test Site       Method         Measurement Frequency Range               U,(dB)

          DG-CB08                                  1GHz ~ 6GHz                      4.02
                          CISPR
            (3m)                                   6GHz ~ 18GHz                     5.10


          Test Site       Method         Measurement Frequency Range               U,(dB)

          DG-CB08                                  18 ~ 26.5 GHz                    3.82
                          CISPR
            (1m)                                   26.5 ~ 40 GHz                    3.90

  Note: Unless specifically mentioned, the uncertainty of measurement has not been taken
        into account to declare the compliance or non-compliance to the specification.

1.3 TEST ENVIRONMENT CONDITIONS

                      Test Item                  Temperature      Humidity         Tested By

    AC Power Line Conducted Emissions                25°C           53%            Lorry Lao

    Radiated emissions 30 MHz to 1 GHz               25°C           60%           Kwok Guo

       Radiated emissions above 1 GHz                25°C           60%           Kwok Guo

                                          Page 6 of 39


                                                                  Report No.: BTL-FCCE-1-1909C106



2. GENERAL INFORMATION

2.1 GENERAL DESCRIPTION OF EUT

  Equipment                          Mobile Phone
  Brand Name                         OPPO
  Test Model                         CPH1941
  Series Model                       N/A
  Model Difference(s)                N/A
  Hardware Version                   ColorOS V6.0.1
  Software Version                   TBD
                                     1. DC Voltage supplied from AC/DC adapter.
                                        1# Model: OP52KAUH
                                        2# Model: OP52JAUH
                                        3# Model: OP52YAUH
                                     2. Supplied from Li-ion Polymer battery.
  Power Source                          1# Factory / Model: NVT / BLP727 (NA-P727-92)
                                        2# Factory / Model: Desay / BLP727 (DA-P727-923)
                                        3# Factory / Model: Sunwoda / BLP727 (XA-P727-922)
                                        4# Factory / Model: Desay / BLP727 (DD-P727-918)
                                        5# Factory / Model: Desay / BLP727 (DA-P727-931)
                                     3. Supplied from USB port.
                                     1. I/P:100-240V~ 50/60Hz 0.4A O/P:5V    2A
  Power Rating                       2. 3.87Vdc, 5000mAh/19.35Wh
                                     3. DC 5V
                                     1* Earphone port
  Connecting I/O Port(s)
                                     1* Type-C port
  Classification of EUT              Class B
 Highest Internal Frequency(Fx)     5825 MHz
Note:
    1. For a more detailed features description, please refer to the manufacturer’s specifications
       or the user's manual.




                                           Page 7 of 39


                                                                 Report No.: BTL-FCCE-1-1909C106



2.2 DESCRIPTION OF TEST MODES

  To investigate the maximum EMI emission characteristics generates from EUT, the test system
  was pre-scanning tested base on the consideration of following EUT operation mode or test
  configuration mode which possible have effect on EMI emission level. Each of these EUT
  operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

    Pretest Mode                                 Description
       Mode 1                          Adapter+ Idle+Playing+Speaker
       Mode 2                          Adapter+ Idle+Playing+earphone
       Mode 3             Adapter+Idle+2.4G WIFI+BT+GPS+NFC+Camera on(Front)
       Mode 4             Adapter+Idle+2.4G WIFI+BT+GPS+NFC+Camera on(Rear)
       Mode 5              Adapter+Idle+5G WIFI+BT+GPS+NFC+Camera on(Front)
       Mode 6                   Adapter+Traffic(GSM)(GSM850.900.1800.1900)
       Mode 7                   Adapter+Traffic(WCDMA)(BAND1.2.4.5.6.8.19)
       Mode 8         Adapter+Traffic(LTE)(BAND1.2.3.4.5.7.8.18.19.20.26.28.38.39.40.41)
       Mode 9                                     FM 88MHz
      Mode 10                                     FM 98MHz
      Mode 11                                    FM 108MHz
      Mode 12                                  USB Copy + Idle

                          AC Power Line Conducted Emissions test
    Final Test Mode                                Description
        Mode 5              Adapter+Idle+5G WIFI+BT+GPS+NFC+Camera on(Front)

                          Radiated Emissions 30 MHz to 1 GHz test
    Final Test Mode                                Description
        Mode 5              Adapter+Idle+5G WIFI+BT+GPS+NFC+Camera on(Front)

                            Radiated emissions above 1 GHz test
    Final Test Mode                                Description
        Mode 5              Adapter+Idle+5G WIFI+BT+GPS+NFC+Camera on(Front)




                                        Page 8 of 39


                                                                Report No.: BTL-FCCE-1-1909C106




  Item         Model           Factory/SN        config1 config2 config3 config4 config5
            OP52KAUH                /                  V
Adapter     OP52YAUH                /                       V
            OP52JAUH                /                                  V       V        V
  USB
                 /                  /                  V    V          V       V        V
 Cable
                                 Desay
              BLP727                                   V
                             /DA-P2727-923
                                Sunwoda
              BLP727                                        V
                             /XA-P727-922

 Battery      BLP727       NVT/NA-P2727-92                             V

                                 Desay
              BLP727                                                           V
                             /DD-P727-918
                                 Desay
              BLP727                                                                    V
                             /DA-P727-931
Earphone         /                  /                  V    V          V       V        V

     Evaluation description:
     1. Mode 1: Tested config1-5. Config 1 is the worst case and tested Mode 2-11.
     2. Mode 12 tested config 1-5.
     3. Config1 with Mode 5 is the worst case and recorded in this report.

     Note:
     1. The product support BT function, the frequency of exemption is 2402- 2480MHz.
     2. The frequency of 2.4G WIFI exemption is 2412-2472MHz.
     3. The frequency of 5G WIFI exemption is 5180-5825MHz.




                                        Page 9 of 39


                                                                                              Report No.: BTL-FCCE-1-1909C106



2.3 EUT OPERATING CONDITIONS

The EUT exercise program used during radiated and/or conducted emission measurement was
designed to exercise the various system components in a manner similar to a typical use. The
standard test signals and output signal as following:
Mode 1-11:
1. EUT connected to earphone via earphone cable.
2. EUT connected to adapter via USB cable.
3. EUT connected to router via WIFI function.
4. EUT connected to BT earphone via BT function.
5. EUT connected to wireless communication test SET via radio signal.
6. EUT connected to signal generator via radio signal.
7. EUT connected to wideband radio communication tester via radio signal.
8. EUT connected to FM STEREO FM-AM signal generator via FM function.
Mode 12:
1. EUT connected to PC via USB cable.
2. PC connected to keyboard and mouse via USB cable.
3. PC connected to monitor via HDMI cable.
4. PC connected to printer via parallel cable.
5. PC connected to modem via RS232 cable.

2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED

                                                               Mode 1-11




                                                                                                                  BT



                                                                                                             (A )B T
                                                                                                           E a rp h o n e


                             (E U T )         1                        2
                            A d a p te r                 EUT                    (E U T )E a rp h o n e
                                                                                                                  W ifi

                         A C 1 0 0~ 2 4 0 V
                                                                                                          (B )w ire le s s
                                                                                                             R o u te r


                   G S M /W C D M A                                                                               GPS
                                                       LTE
                                                                                     FM



         (C ) W ire le s s               (D )W id e b a n d R a d io   (F ) F M S T E R E O                (E ) S ig n a l
       C o m m u n ic a tio n              C o m m u n ic a tio n          F M -A M S IG N A L             G e n e ra to r
           Test SET                              T e s te r                 GENERATOR

                                                                                                              G ro u n d p la n e

                                                                                                            R e m o te S y s te m




                                                           Page 10 of 39


                                      Report No.: BTL-FCCE-1-1909C106



               Mode 12


AC 100-240 V


      4

                     8
                             (L) M odem
                     7
                             (K) P rinter
                     6
                              (J) M ouse
                     5
                             (I) K eyboard
(G ) PC

                     3        (H ) M onitor

                         1                    2
                                 EUT              (E U T)E arphone




                                                    G round plane
                                                   R em ote System




           Page 11 of 39


                                                                     Report No.: BTL-FCCE-1-1909C106



2.5 DESCRIPTION OF SUPPORT UNITS

The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.

 Item      Equipment           Mfr/Brand            Model/Type No.              Series No.
  A       BT earphone          MICROKIA                       M9                   N/A
  B      wireless router            ASUS               RT-AC66U             E8ICGG000138
            Wireless
                                                     (8960 Series)
  C     Communication               Agilent                                   MY48364183
                                                        E5515C
            Test SET
        Wideband Radio
  D     Communication                RS                CMW500                    122125
             Tester
  E     Signal Generator            Agilent             E4438C                MY49071316
          FM STEREO
   F    FM-AM SIGNAL          KENWOOD                   SG-5110                 HR1010099
         GENERATOR
  G            PC                  Dell 745              DCSM                   G7K832X
  H          Monitor               PHILIPS              241P6V             UHBA1633026326
   I        Keyboard                 Dell                 L100         CNORH6596589071T08NE
   J         Mouse                   Dell              MO56UOA                  FQJ000BS
  K          Printer                  SII              DPU-414                  3018507 B
   L         Modem                 ACEEX               DM-1414V               0603002131

 Item                  Cable Type                    Shielded Type     Ferrite Core       Length
   1                   USB Cable                          YES              NO                1m
   2              Earphone Cable                          NO               NO                1m
   3                   HDMI Cable                         YES              NO             1.8m
   4                    AC Cable                          NO               NO             1.8m
   5                   USB Cable                          YES              NO             1.8m
   6                   USB Cable                          YES              NO             1.8m
   7                Parallel cable                        YES              NO             1.8m
   8                RS232 cable                           YES              NO             1.8m




                                              Page 12 of 39


                                                                 Report No.: BTL-FCCE-1-1909C106



3. EMC EMISSION TEST

3.1 AC POWER LINE CONDUCTED EMISSIONS TEST

3.1.1 LIMIT

                                                         Class B (dBuV)
  Frequency of Emission (MHz)
                                            Quasi-peak                        Average
              0.15 - 0.5                     66 - 56 *                        56 - 46 *
              0.5 - 5.0                        56.00                           46.00
              5.0 - 30.0                       60.00                           50.00

Note:
  (1) The tighter limit applies at the band edges.
  (2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of
      the frequency in the range.
  (3) The test result calculated as following:
      Measurement Value = Reading Level + Correct Factor
      Correct Factor = Insertion Loss + Cable Loss + Attenuator Factor(if use)
      Margin Level = Measurement Value - Limit Value

3.1.2 MEASUREMENT INSTRUMENTS LIST

Item Kind of Equipment       Manufacturer         Type No.      Serial No.       Calibrated until
  1 EMI Test Receiver           R&S                 ESCI         100382          Mar. 10, 2020
 2         LISN                 EMCO               3816/2         52765           Mar. 10, 2020
         TWO-LINE
 3                               R&S              ENV216         101447           May. 19, 2020
        V-NETWORK
 4     50Ω Terminator            SHX               TF5-3        15041305          Mar. 10, 2020
                                                  EZ-EMC
       Measurement
 5                               Farad          Ver.NB-03A1        N/A                    N/A
        Software
                                                     -01
 6            Cable               N/A              RG223           12m            Mar. 12, 2020

  Remark: “N/A” denotes no model name, serial no. or calibration specified.
          All calibration period of equipment list is one year.




                                         Page 13 of 39


                                                                  Report No.: BTL-FCCE-1-1909C106



3.1.3 TEST PROCEDURE
a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
    to the power mains through a line impedance stabilization network (LISN). All other support
    equipment powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
    impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
    and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
    cable may be terminated, if required, using the correct terminating impedance. The overall
    length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis.
e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
f. Measuring frequency range from 150KHz to 30MHz.

3.1.4 DEVIATION FROM TEST STANDARD
No deviation

3.1.5 TEST SETUP




3.1.6 TEST RESULTS

Remark:
     (1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
         Detector BW=9 kHz; SPA setting in RBW=10 kHz, VBW =10 kHz, Swp. Time = 0.3
         sec./MHz. Reading in which marked as AV means measurements by using are Average
         Mode with instrument setting in RBW=10 kHz, VBW=10 kHz, Swp. Time =0.3 sec./MHz.
     (2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP
         Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
         shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
         but AVG Mode didn‘t perform. In this case, a “ * ” marked in AVG Mode column of
         Interference Voltage Measured.




                                          Page 14 of 39


                                                   Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Phase         Line
Test Mode      Mode 5(Config1)




                                 Page 15 of 39


                                                   Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Phase         Neutral
Test Mode      Mode 5(Config1)




                                 Page 16 of 39


                                                                            Report No.: BTL-FCCE-1-1909C106



 3.2 RADIATED EMISSIONS 30 MHZ TO 1 GHZ

3.2.1 LIMIT

                                                         Class B (at 3m)
            Frequency
                                          (uV/m)                               (dBuV/m)
              (MHz)
                                      Field strength                         Field strength
             30 - 88                        100                                   40
            88 - 216                        150                                  43.5
           216 - 960                        200                                   46
           Above 960                        500                                   54


NOTE:
(1) The tighter limit applies at the band edges.
(2) Emission level (dBuV/m) = 20log Emission level (uV/m).
    3m Emission level = 10m Emission level + 20log(10m/3m).
(3) The test result calculated as following:
    Measurement Value = Reading Level + Correct Factor
    Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain(if use)
    Margin Level = Measurement Value - Limit Value

3.2.2 MEASUREMENT INSTRUMENTS LIST

Item Kind of Equipment Manufacturer                    Type No.              Serial No. Calibrated until
  1      Receiver       Keysight                       N9038A               MY54450004 Aug. 03, 2020
 2    MXE EMI Receiver          Agilent                N9038A               MY53220133        Mar. 10, 2020
                                 EMC
 3       Pre-Amplifier       INSTRUMEN               EMC 9135                 980284          Mar. 10, 2020
                                  T
                                 EMC
 4       Pre-Amplifier       INSTRUMEN               EMC 9135                 980283          Mar. 10, 2020
                                  T
       Trilog-Broadband
 5                      Schwarzbeck                  VULB9168                   946           Nov. 24, 2019
            Antenna
       Trilog-Broadband
 6                      Schwarzbeck                  VULB9168                   947           Nov. 24, 2019
            Antenna
                                              LMR-400(5m+11m+15
 7            Cable               emci                                          N/A           Aug. 06, 2020
                                                      m)
 8           Cable                emci        LMR-400(5m+8m+8m)                 N/A           Aug. 06, 2020
         Measurement                                EZ-EMC
 9                               Farad                                          N/A               N/A
           Software                             Ver.BTL-2ANT-1
         Multi-Device         ETS-Lindgre
 10                                                      2090                   N/A               N/A
          Controller              n
 11       Attenuator            EMCI                EMCI-N-6-06                N0670          Nov. 24, 2019
 12        Attenuator             EMCI              EMCI-N-6-06                N0671          Nov. 24, 2019

 Remark: “N/A” denotes no model name, no serial no. or no calibration specified.
         All calibration period of equipment list is one year.




                                               Page 17 of 39


                                                                   Report No.: BTL-FCCE-1-1909C106



3.2.3 TEST PROCEDURE
a. The measuring distance of 3 m shall be used for measurements. The EUT was placed on the
    top of a rotating table 0.8 meter above the ground at a 10 meter semi-anechoic chamber. The
    table was rotated 360 degrees to determine the position of the highest radiation.
b. The height of the equipment or of the substitution antenna shall be 0.8 m, the height of the test
    antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
    antenna are set to make the measurement.
c. For each suspected emission, the EUT was arranged to its worst case and then the antenna
    was tuned to heights find the maximum reading (used Bore sight function).
d. The initial step in collecting radiated emission data is a receiver peak detector mode
    pre-scanning the measurement frequency range. Significant peaks are then marked and then
    Quasi Peak detector mode re-measured.
e. All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the
    Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform.
f. For the actual test configuration, please refer to the related Item - Block Diagram of system
    tested.

3.2.4 DEVIATION FROM TEST STANDARD
No deviation

3.2.5 TEST SETUP
                                        30 MHz to 1 GHz




3.2.6 TEST RESULTS

 Remark:
     (1) Measuring frequency range from 30 MHz to 1000 MHz
     (2) If the peak scan value lower limit more than 20 dB, then this signal data does not show
         in table.




                                          Page 18 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Vertical
Test Mode      Mode 5(Config1)




                                 Page 19 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Horizontal
Test Mode      Mode 5(Config1)




                                 Page 20 of 39


                                                                            Report No.: BTL-FCCE-1-1909C106



 3.3 RADIATED EMISSIONS ABOVE 1 GHZ

3.3.1 LIMIT
                                                               Class B
           Frequency
                                                           (dBuV/m) (at 3m)
             (MHz)
                                               Peak                               Average
          Above 1000                            74                                  54

FREQUENCY RANGE OF RADIATED MEASUREMENT (FOR UNINTENTIONAL RADIATORS)

     Highest frequency generated or Upper
 frequency of measurement used in the device
                                                                            Range (MHz)
    or on which the device operates or tunes
                     (MHz)
                    Below 1.705                                               30
                    1.705 - 108                                              1000
                      108 - 500                                              2000
                     500 - 1000                                              5000
                                                           5th harmonic of the highest frequency or
                    Above 1000
                                                                  40 GHz, whichever is lower

NOTE:
(1) The tighter limit applies at the band edges.
(2) Emission level (dBuV/m) = 20log Emission level (uV/m).
    3m Emission level = 10m Emission level + 20log(10m/3m).
(3) The test result calculated as following:
    Measurement Value = Reading Level + Correct Factor
    Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain(if use)
    Margin Level = Measurement Value - Limit Value




                                               Page 21 of 39


                                                               Report No.: BTL-FCCE-1-1909C106



3.3.2 MEASUREMENT INSTRUMENTS LIST

Item Kind of Equipment   Manufacturer          Type No.         Serial No.    Calibrated until
  1    Horn Antenna        EMCO                  3115           9605-4803     Mar. 23, 2020
     Broad-Band Horn
  2                      Schwarzbeck          BBHA 9170          9170319          Jun. 23, 2020
          Antenna
  3       Amplifier         Agilent             8449B          3008A02584         Aug. 03, 2020
        Microwave            EMC
                                                                 980039 &
  4  Preamplifier With   INSTRUMEN          EMC2654045                            Mar. 10, 2020
                                                                   HA01
          Adaptor             T
  5 MXE EMI Receiver        Agilent            N9038A          MY53220133         Mar. 10, 2020
       Measurement                             EZ-EMC
  6                         Farad                                   N/A               N/A
         Software                          Ver.BTL-2ANT-1
        Multi-Device     ETS-Lindgre
  7                                              2090               N/A               N/A
         Controller          n
                                                               MF78020815
 8       Controller          MF                MF-7802                                N/A
                                                                   9
                                            SUCOFLEX
 9         Cable            emci         102_8m(0.01GHz-            N/A           Mar. 26, 2020
                                              40GHz)
10         Cable         MIcable Inc.      B10-01-01-5M          18047123         Mar. 01, 2020
11         Cable         MIcable Inc.      B10-01-01-10M         18072746         Mar. 01, 2020
12         Cable             N/A        A50-3.5M3.5M-1.5M-AT     18041824         Mar. 01, 2020

Remark: “N/A” denotes no model name, no serial no. or no calibration specified.
        All calibration period of equipment list is one year.




                                         Page 22 of 39


                                                                   Report No.: BTL-FCCE-1-1909C106



3.3.3 TEST PROCEDURE
a. The measuring distance of 3 m shall be used for measurements. The EUT was placed on the
    top of a rotating table 0.8 meter above the ground at a 10 meter semi-anechoic chamber. The
    table was rotated 360 degrees to determine the position of the highest radiation.
    Note:
    For measurement of frequency 1GHz -18GHz, the EUT was set 3 meters away from the
    receiver antenna. For 18G – 40GHz, the EUT was set 1 meter.
    Emission level (dBuV/m)=20log Emission level (uV/m).
    The limits above 18GHz shall be extrapolated to the specified distance using an
    extrapolation factor of 20dB/decade from 3m to 1m
    Distance extrapolation factor = 20 log (3m/1m) dB ;
    Limit line = specific limits (dBuV) + 9.5 dB.
b. The height of the equipment or of the substitution antenna shall be 0.8 m, the height of the test
    antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
    antenna are set to make the measurement.
c. For each suspected emission, the EUT was arranged to its worst case and then the antenna
    was tuned to heights find the maximum reading (used Bore sight function).
d. The initial step in collecting radiated emission data is a receiver peak detector mode
    pre-scanning the measurement frequency range. Significant peaks are then marked and then
    Quasi Peak detector mode re-measured.
e. The receiver system was set to peak and average detect function and specified bandwidth
    with maximum hold mode when the test frequency is above 1 GHz.
f. All readings are Peak Mode value unless otherwise stated AVG in column of Note. If the Peak
    Mode Measured value compliance with the Peak Limits and lower than AVG Limits, the EUT
    shall be deemed to meet both Peak & AVG Limits and then only Peak Mode was measured,
    but AVG Mode didn‘t perform.
g. For the actual test configuration, please refer to the related Item - Block Diagram of system
    tested.

3.3.4 DEVIATION FROM TEST STANDARD
No deviation




                                          Page 23 of 39


                                   Report No.: BTL-FCCE-1-1909C106




3.3.5 TEST SETUP

                   1 GHz-18 GHz




                   18 GHz-40 GHz




                   Page 24 of 39


                                                                    Report No.: BTL-FCCE-1-1909C106



3.3.6 TEST RESULTS

 Remark:
     (1) Radiated emissions measured in frequency range above 1000 MHz were made with an
         instrument using Peak detector mode and AV detector mode of the emission.
     (2) Data of measurement within this frequency range shown “ * ” in the table above means the
         reading of emissions are attenuated more than 20 dB below the permissible limits or the field
         strength is too small to be measured.
     (3) A preamp and high pass filter were used for this test in order to provide sufficient
         measurement sensitivity.




                                           Page 25 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Vertical
Test Mode      Mode 5(Config1)




                                 Page 26 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Horizontal
Test Mode      Mode 5(Config1)




                                 Page 27 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Vertical
Test Mode      Mode 5(Config1)




                                 Page 28 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Horizontal
Test Mode      Mode 5(Config1)




                                 Page 29 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Vertical
Test Mode      Mode 5(Config1)




                                 Page 30 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Horizontal
Test Mode      Mode 5(Config1)




                                 Page 31 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Vertical
Test Mode      Mode 5(Config1)




                                 Page 32 of 39


                                                          Report No.: BTL-FCCE-1-1909C106




Test Voltage   AC 120V/60Hz                Polarization         Horizontal
Test Mode      Mode 5(Config1)




                                 Page 33 of 39



Document Created: 2019-10-24 16:02:36
Document Modified: 2019-10-24 16:02:36

© 2024 FCC.report