RF Exposure

FCC ID: R7PEG1R1S5

RF Exposure Info

Download: PDF
FCCID_2418043

                   Certification Exhibit



                     FCC ID: R7PEG1R1S5
                      IC: 5294A-EG1R1S5

              FCC Rule Part: 15.247
    IC Radio Standards Specification: RSS-210

               ACS Project Number: 14-0179

      Manufacturer: Landis+Gyr Technology, Inc.
                 Model: G5 26-1905




                         RF Exposure




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: G5 26-1905                             FCC ID: R7PEG1R1S5                      IC: 5294A-EG1R1S5


General Information:
Applicant:           Landis+Gyr Technology, Inc.
Environment:         General Population/Uncontrolled Exposure
Exposure Conditions: Mobile

Technical Information – 900MHz Gridstream Radio:
Antenna Type: Inverted F
Antenna Gain: 3dBi
Maximum Transmitter Conducted Power: 29.63 dBm, 918.33 mW
Maximum System EIRP: 32.63 dBm, 1832.32 mW

Technical Information – Zigbee Radio:
Antenna Type: Inverted F
Antenna Gain: 5dBi
Maximum Transmitter Conducted Power: 20.71 dBm, 117.76 mW
Maximum System EIRP: 25.71 dBm, 372.39 mW

MPE Calculation
The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4R 2
Where:
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                                  MPE Calculator for Mobile Equipment
                          Limits for General Population/Uncontrolled Exposure
  Transmit       Radio         Power          Radio    Antenna Antenna
                                                                           Distance Power Density
 Frequency       Power      Density Limit    Power       Gain   Gain (mW
                                                                             (cm)    (mW/cm^2)
   (MHz)         (dBm)       (mW/Cm2)         (mW)       (dBi)      eq.)
    902.2         29.63          0.60        918.33        3       1.995      20       0.365
    2405          20.71          1.00        117.76        5       3.162      20       0.074

Summation of Power Densities – Simultaneous Transmissions
This device contains multiple transmitters which can operate simultaneously; therefore the
maximum RF exposure is determined by the summation of MPE ratios. The limit is such that the
summation of MPE ratios is ≤ 1.0.

The summation of MPE ratios is as follows:
        900 LAN MPE Ratio + Zigbee MPE Ratio
        (0.365 / 0.60) + (0.074 / 1.0) = (0.608) + (0.074) = 0.682
        0.682 < 1

RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element
shall be installed such that a minimum separation distance of 20 centimeters will be maintained.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.



     ACS Project: 14-0179                   Advanced Compliance Solutions                      Page 2



Document Created: 2019-10-07 00:28:26
Document Modified: 2019-10-07 00:28:26

© 2024 FCC.report