test report

FCC ID: R38YLWM0404

Test Report

Download: PDF
FCCID_419824

            FCC PART 90
  EMI MEASUREMENT AND TEST REPORT
                                           For

 YULONG COMPUTER TELECOMMUNICATION
     SCIENTIFIC (SHENZHEN) CO. LTD
           8/F, B TOWER, HIGH TECH. PLAZA, TIANAN CRYBERPARK,
                             SHENZHEN, CHINA


                             FCC ID: R38YLWM0404



   This Report Concerns:                     Equipment Type:
      Original Report                        Wireless Data Modem


      Test Engineer:     Ming Jin


    Report Number:       R0404063


        Report Date:     2004-04-26


       Reviewed By:      Ling Zhang


       Prepared By:      Bay Area Compliance Laboratory Corporation
                         230 Commercial Street
                         Sunnyvale, CA 94085
                         Tel: (408) 732-9162
                         Fax: (408) 732 9164




Note: This test report is specially limited to the above client company and product model. It may
      not be duplicated without prior written consent of Bay Area Compliance Laboratory
      Corporation. This report must not be used by the client to claim product endorsement by
      NVLAP or any agency of the U.S. Government.


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                                                                            FCC ID: R38YLWM0404

TABLE OF CONTENTS
GENERAL INFORMATION.......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED GRANT/SUBMISSION.....................................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................3
SYSTEM TEST CONFIGURATION..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  SPECIAL ACCESSORIES .................................................................................................................................................5
  SCHEMATICS / BLOCK DIAGRAM .................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5
  EXTERNAL I/O CABLING LIST AND DETAILS ...............................................................................................................5
  POWER SUPPLY AND LINE FILTERS ..............................................................................................................................5
  CONFIGURATION OF TEST SYSTEM ..............................................................................................................................6
  TEST SETUP BLOCK DIAGRAM .....................................................................................................................................6
REQUIREMENTS OF PROVISIONS ........................................................................................................................7
  REQUIREMENTS AND TEST SUMMARY .........................................................................................................................7
  LABELING REQUIREMENT ............................................................................................................................................7
§2.1046 AND §90.205(J) - CONDUCTED OUTPUT POWER..................................................................................8
  PROVISION APPLICABLE...............................................................................................................................................8
  TEST PROCEDURE ........................................................................................................................................................8
  TEST EQUIPMENT .........................................................................................................................................................8
  TEST RESULTS .............................................................................................................................................................8
§2.1049, AND §90.209 - OCCUPIED BANDWIDTH OF EMISSION ...................................................................10
  PROVISION APPLICABLE.............................................................................................................................................10
  TEST PROCEDURE ......................................................................................................................................................10
  TEST EQUIPMENT .......................................................................................................................................................10
  TEST RESULTS ...........................................................................................................................................................10
§2.1053 AND §90.210 - RADIATED SPURIOUS EMISSION ................................................................................13
  PROVISION APPLICABLE.............................................................................................................................................13
  TEST PROCEDURE ......................................................................................................................................................13
  TEST EQUIPMENT .......................................................................................................................................................13
  TEST RESULT .............................................................................................................................................................14
§2.1051 AND §90.210 - SPURIOUS EMISSION AT ANTENNA TERMINAL ...................................................15
  STANDARD APPLICABLE ............................................................................................................................................15
  MEASUREMENT PROCEDURE......................................................................................................................................15
  TEST EQUIPMENT .......................................................................................................................................................15
  TEST RESULT .............................................................................................................................................................15
§90.265(B)(3) - FREQUENCY STABILITY MEASUREMENT ............................................................................17
  PROVISION APPLICABLE.............................................................................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  TEST EQUIPMENT .......................................................................................................................................................17
  TEST RESULTS ...........................................................................................................................................................18




Report # R0404063Rpt                                                  Page 2 of 18                                                      FCC Part 90 Test Report


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                     FCC ID: R38YLWM0404


GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)
The YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD’s Model:
PIP-900 or the “EUT” as referred to in this report is a wireless data modem, transmitter part, which
measures approximately 11.2cmL x 5.8cmW x 3.0cmH. The EUT operates at frequency 896 – 901MHz
with maximum ERP of 1.36W, frequency tolerance 1.5ppm and emission designator F3D.

* The test data gathered are from production sample, serial number: PIP-900-001, provided by the
manufacturer.


Objective
This report is prepared on behalf of YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC
(SHENZHEN) CO. LTD in accordance with Part 90 Subpart A Subpart I and Subpart S of the Federal
Communication Commissions rules.

The objective of the manufacturer is to demonstrate compliance with FCC rules for effective radiated
power, modulation characteristics, occupied bandwidth, radiated spurious emissions, and frequency
stability.


Related Grant/Submission
No Related Submittals.


Test Methodology
Measurements contained in this report were also conducted with TIA/EIA Standard 603,
Telecommunications Industry Association Land Mobile FM or PM Communications Equipment
Measurement and Performance Standards.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratory,
Corp. The radiated testing was performed at an antenna-to-EUT distance of 3 meters.


Test Facility
The Open Area Test site used by Bay Area Compliance Laboratory Corporation to collect radiated and
conducted emission measurement data is located in the back parking lot of the building at 230 Commercial
Street, Sunnyvale, California, USA.

Test site at Bay Area Compliance Laboratory Corporation has been fully described in reports submitted to
the Federal Communication Commission (FCC) and Voluntary Control Council for Interference (VCCI).
The details of these reports has been found to be in compliance with the requirements of Section 2.948 of
the FCC Rules on February 11 and December 10, 1997 and Article 8 of the VCCI regulations on
December 25, 1997. The facility also complies with the radiated and AC line conducted test site criteria
set forth in ANSI C63.4-1992.

The Federal Communications Commission and Voluntary Control Council for Interference has the reports
on file and is listed under FCC file 31040/SIT 1300F2 and VCCI Registration No.: C-1298 and R-1234.
The test site has been approved by the FCC and VCCI for public use and is listed in the FCC Public
Access Link (PAL) database.
Report # R0404063Rpt                      Page 3 of 18                            FCC Part 90 Test Report


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                 FCC ID: R38YLWM0404

Additionally, Bay Area Compliance Laboratory Corporation is a National Institute of Standards and
Technology (NIST) accredited laboratory, under the National Voluntary Laboratory Accredited Program
(NVLAP). The scope of the accreditation covers the FCC Method - 47 CFR Part 15 - Digital Devices,
CISPR 22: 1997, and AS/NZS 3548: Electromagnetic Interference - Limits and Methods of Measurement
of Information Technology Equipment test methods under NVLAP Lab Code 200167-0.




Report # R0404063Rpt                    Page 4 of 18                          FCC Part 90 Test Report


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                           FCC ID: R38YLWM0404


SYSTEM TEST CONFIGURATION
Justification
The EUT was tested under typical operating modes to represent the worst-case results during the final
qualification test.


Special Accessories
As shown in the test setup block diagram, interface cable used for compliance testing is shielded as
normally supplied by customer and its respective support equipment manufacturers.


Schematics / Block Diagram
Please refer to Appendix D.


Equipment Modifications
No modification was made by BACL Corp. to make sure the EUT to comply with the applicable limits.


Local Support Equipment List and Details

 Manufacturer          Description            Model                Serial Number                  FCC ID
      Dell           Notebook PC             PS04RC                       N/A                       N/A


External I/O Cabling List and Details

     Cable Description          Length (M)               From                              To
   RSS232 and Power Cable          0.5           RSS232 and Power Cable         Notebook PC / RSS232 Port
   RSS232 and Power Cable          0.5             EUT / RSS232 Port                 AC/DC Adapter
       Antenna Cable               1.0             EUT / Antenna Port                   Antenna



Power Supply and Line Filters

   Manufacturer            Description              Model                 Serial Number            FCC ID
     Yulong              AC Power supply          PRS-Z30US7                   N/A                  N/A




Report # R0404063Rpt                         Page 5 of 18                             FCC Part 90 Test Report


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                             FCC ID: R38YLWM0404

Configuration of Test System




                                                            Adapter




                                                EUT

              Notebook
                                                                             Antenna




Test Setup Block Diagram




                                                                      EUT Power Cord
                    Peripheral                        Adapter                          LISN1
                   Power Cords
     LISN 2




                          Notebook      10     EUT
                                        cm


                                                                                           1 Meter


                                                                          Antenna

                   Non-Conducting Table
                 80 cm Above Ground Plane




                                              1.5 Meters




Report # R0404063Rpt                         Page 6 of 18                                 FCC Part 90 Test Report


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                        FCC ID: R38YLWM0404


REQUIREMENTS OF PROVISIONS
Requirements and Test Summary

         FCC Rules                    Rules Description                    Result
          2.1046
                                      RF Output Power                     Complied
         90.205 (j)

          2.1049
                                     Occupied Bandwidth                   Complied
         90.210 (j)

           2.1053
                                  Radiated Spurious Emission              Complied
           90.210
           2.1051
                              Spurious Emission at Antenna Port           Complied
           90.210
                                     Frequency Stability
           2.1055
                                      Vs. Temperature                     Complied
           90.213
                                        Vs. Voltage


Labeling Requirement
Each equipment for which a type acceptance applications is filed on or after May 1, 1981, shall bear an
identification plate or label pursuant to §2.295 (Identification of Equipment) and §2.926 (FCC identifier)

In August 1996 the Federal Communications Commissions (FCC) adopted RF exposure guidelines with
safety levels for hand-held wireless devices.

Generally users manual contains a RF exposure statement to indicate compliance with FCC requirements.




Report # R0404063Rpt                       Page 7 of 18                              FCC Part 90 Test Report


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                            FCC ID: R38YLWM0404


§2.1046 and §90.205(j) - CONDUCTED OUTPUT POWER
Provision Applicable
Per FCC §2.1046 and §90.205(j): the output power shall not exceed 100W.


Test Procedure
The RF output of the transceiver was connected to a spectrum analyzer through appropriate attenuator.


Test Equipment

      Manufacturer          Description             Model         Serial Number         Cal. Due Date
      Hewlett Packard    Spectrum Analyzer         HP8565C             06042             2004-05-03
      Hewlett Packard          Plotter            HP7470A                 N/A                N/A

    * Statement of Traceability: BACL Corp. certifies that all calibrations have been performed in accordance to
    NVLAP requirements, traceable to the NIST.


Test Results
     Environmental Conditions

   Temperature:             25° C
   Relative Humidity:       38 %
   ATM Pressure:            1032mbar

The testing was performed by Ming Jing on 2004-04-25.

                           Frequency       Output Power in dBm        Output Power in
                                                                            W
                            896.013                31.00                  1.259
                            900.988                31.33                  1.358

Please refer to the following plots.




Report # R0404063Rpt                         Page 8 of 18                                FCC Part 90 Test Report


Mn


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                                                      FCC ID: R38YLWM0404


§2.1049, and §90.209 - OCCUPIED BANDWIDTH OF EMISSION
Provision Applicable
Per FCC §2.1049, and §90.209, the emission bandwidth shall not exceed 12.5KHz.

For any frequency removed from the center of the assigned channel by more than 50 percent up to and
including 100 percent of the authorized bandwidth, at least 25 dB.

On any frequency removed from the center of the assigned channel by more than 100 percent up to and
including 250 percent, at least 35 dB.

On any frequency removed from the center of the assigned channel by more than 250 percent at least:

50 + 10 log(P) dBm


Test Procedure
The transmitter was connected to a spectrum analyzer via a low lose cable. The resolution bandwidth of
the spectrum analyzer was set up to 1KHz and the spectrum of the transmitting signal was recorded. This
spectrum was compared to the required emission mask.


Test Equipment

          Manufacturer                    Description                 Model No.               Serial No.                Calibration Date
                                       DRG Spectrum
              Agilent                                                  8565EC               3946A00131                     2003-06-30
                                         Analyzer
        Hewlett Packard                      Plotter                  HP7470A                     N/A                           N/A
            NAAYAN                    Audio Generator                  NY2201                    00042                          N/A

    2003. . ............................................................................................. Statement of Traceability: BACL Corp.
        certifies that all calibrations have been performed in accordance to NVLAP requirements, traceable to the
        NIST.


Test Results
     Environmental Conditions

   Temperature:                    25° C
   Relative Humidity:              38 %
   ATM Pressure:                   1032mbar

The testing was performed by Ming Jing on 2004-04-25.

Test Result: Pass
Please refer the following curve and plots.




Report # R0404063Rpt                                      Page 10 of 18                                           FCC Part 90 Test Report






YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                            FCC ID: R38YLWM0404


§2.1053 and §90.210 (j) – RADIATED SPURIOUS EMISSION
Provision Applicable
Per FCC §2.1053and FCC §90.210 (j)

On any frequency removed from the center of the assigned channel by more than 250 percent at least:

50 + 10 log(P) dBm


Test Procedure
The transmitter was placed on a wooden turntable, and it was transmitting into a non-radiating load which
was also placed on the turntable.

The measurement antenna was placed at a distance of 3 meters from the EUT. During the tests, the antenna
height and polarization as well as EUT azimuth were varied in order to identify the maximum level of
emissions from the EUT. The test was performed by placing the EUT on 3-orthogonal axis.

The frequency range up to tenth harmonic of the fundamental frequency was investigated.

Remove the EUT and replace it with substitution antenna. A signal generator was connected to the
substitution antenna by a non-radiating cable. The absolute levels of the spurious emissions were measured
by the substitution.

Spurious emissions in dB = 10 lg (TXpwr in Watts/0.001) – the absolute level

Spurious attenuation limit in dBm = 50 + 10 log(P)


Test Equipment


      Manufacturer          Description              Model        Serial Number           Cal. Date
          EMCO           Biconical Antennas          3110B           9603-2315           2003-10-11
                            Log-Periodic
          EMCO                                        3148           0004-1155           2003-10-11
                              Antenna
        A.H. System         Horn Antenna         SAS-200/571          2455-261           2003-08-02
                           DRG Spectrum
          Agilent                                   8565EC          3946A00131           2003-06-30
                             Analyzer
         Rohde &
                          Signal Generator          SMIQ03           DE237467            2003-07-03
         Schwarz
       Mini-Circuits       High Pass Filter        NHP-1200            10312                 N/R

    * Statement of Traceability: BACL Corp. certifies that all calibrations have been performed in accordance to
    NVLAP requirements, traceable to the NIST.




Report # R0404063Rpt                          Page 13 of 18                             FCC Part 90 Test Report


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                                 FCC ID: R38YLWM0404

Test Result
     Environmental Conditions

   Temperature:                 25° C
   Relative Humidity:           38 %
   ATM Pressure:                1032mbar

The testing was performed by Ming Jing on 2004-04-25.

Low Frequency: -1.1 dB at 2688.0375 MHz
High Frequency: -1.1 dB at 2702.9625 MHz


Primary scan at Low Frequency 896.0125MHz

                       EUT                                               Generator                         Standard

     Indicated          Table     Test Antenna           Substitution         Antenna Cable Absolute FCC         FCC

Frequency    Ampl.      Angle      Height   Polar Frequency      Level   Polar Gain    Loss     Level    Limit   Margin
  MHz       dBuV/m      Degree     Meter    H/V     MHz          dBm     H/V Corrected DB       dBm      dBm      DB
896.0125       104.2     30         1.2      v   896.0125        26.53    v      6.5   0.2      32.83
896.0125       99.6      130        1.8      h   896.0125        21.92    h      6.5   0.2      28.22
2688.0375      43.2      195        1.3      h   2688.0375       -29.1    h      8.7   0.7      -21.1    -20      -1.1
2688.0375      42.6      172        1.4      v   2688.0375       -29.3    v      8.7   0.7      -21.3    -20      -1.3
1792.025       45.2      160        1.2      h   1792.025        -27.7    h      6.8   0.5      -21.4    -20      -1.4
1792.025       44.9      270        1.4      v   1792.025        -28.1    v      6.8   0.5      -21.8    -20      -1.8
 3584.05       33.2      172        1.4      v    3584.05        -34.8    v     10.8   0.9      -24.9    -20      -4.9
 3584.05       30.1      195        1.3      h    3584.05        -37.1    h     10.8   0.9      -27.2    -20      -7.2


Primary scan at High Frequency 900.987MHz

                       EUT                                               Generator                         Standard

     Indicated          Table     Test Antenna           Substitution         Antenna Cable Absolute FCC         FCC

Frequency    Ampl.      Angle      Height   Polar Frequency      Level   Polar Gain    Loss     Level    Limit   Margin
  MHz       dBuV/m      Degree     Meter    H/V     MHz          dBm     H/V Corrected DB       dBm      dBm      DB
900.9875       102.8     74         1.5      v   900.9875        25.27    v      6.5   0.2      31.57
900.9875       99.2      190        1.2      h   900.9875        21.85    h      6.5   0.2      28.15
2702.9625      42.7      64         1.3      v   2702.9625       -29.1    v      8.7   0.7      -21.1    -20      -1.1
1801.975       45.1      55         1.5      v   1801.975        -27.5    v      6.8   0.5      -21.2    -20      -1.2
2702.9625      41.8      90         1.3      h   2702.9625       -30.2    h      8.7   0.7      -22.2    -20      -2.2
1801.975       43.5      95         1.2      h   1801.975         -29     h      6.8   0.5      -22.7    -20      -2.7
 3603.95       32.7      64         1.3      v    3603.95        -35.4    v     10.8   0.9      -25.5    -20      -5.5
 3603.95       32.4      90         1.3      h    3603.95        -35.8    h     10.8   0.9      -25.9    -20      -5.9


Result: Pass
Test was performed in three orthogonal plane.


Report # R0404063Rpt                             Page 14 of 18                                FCC Part 90 Test Report


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                            FCC ID: R38YLWM0404


§2.1051 and §90.210 - SPURIOUS EMISSION AT ANTENNA TERMINAL
Standard Applicable
Per FCC §2.1051and FCC §90.210

On any frequency removed from the center of the assigned channel by more than 250 percent at least:

50 + 10 log(P) dBm


Measurement Procedure
The RF output of the transceiver was connected to a spectrum analyzer through appropriate attenuation.
The resolution bandwidth of the spectrum analyzer was set at 100 kHz. Sufficient scans were taken to
show any out of band emissions up to 10th harmonic.


Test Equipment

         Manufacturer              Description            Model No.      Serial No.          Calibration Date
                               DRG Spectrum
            Agilent                                         8565EC      3946A00131             2003-06-30
                                 Analyzer

    * Statement of Traceability: BACL Corp. certifies that all calibrations have been performed in accordance to
    NVLAP requirements, traceable to the NIST.


Test Result
     Environmental Conditions

   Temperature:             25° C
   Relative Humidity:       38 %
   ATM Pressure:            1032mbar

The testing was performed by Ming Jing on 2004-04-25.

Please refer to following plots.




Report # R0404063Rpt                             Page 15 of 18                          FCC Part 90 Test Report


paotnnviercaoae


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                            FCC ID: R38YLWM0404


§90.265(b)(3) - FREQUENCY STABILITY MEASUREMENT
Provision Applicable
According to §90.265(b)(3), the frequency stability of the wireless microphones shall limit the total
emission to within +-32.5KHz of the assigned frequency.


Test Procedure
     Frequency stability versus environmental temperature

The equipment under test was connected to an external DC power supply and the RF output was connected
to a frequency counter via feedthrough attenuators. The EUT was placed inside the temperature chamber.

After the temperature stabilized for approximately 20 minutes, the frequency of the output signal was
recorded from the counter.


     Frequency Stability versus Input Voltage

At room temperature (25±5°C), an external variable DC power supply was connected to the EUT. The
frequency of the transmitter was measured for 115%, 100% and 85% of the nominal operating input
voltage.


Test Equipment


      Manufacturer          Description             Model         Serial Number           Cal. Date
                            Temperature
          Tenney             Chamber                Versa            12.222-193          2003-04-23
                           –500 to +1000C
                           DRG Spectrum
          Agilent                                  8565EC           3946A00131           2003-06-30
                             Analyzer

    * Statement of Traceability: BACL Corp. certifies that all calibrations have been performed in accordance to
    NVLAP requirements, traceable to the NIST.




Report # R0404063Rpt                         Page 17 of 18                              FCC Part 90 Test Report


YULONG COMPUTER TELECOMMUNICATION SCIENTIFIC (SHENZHEN) CO. LTD                       FCC ID: R38YLWM0404

Test Results

                              Reference Frequency: 896.0125 MHz, Limit: 1.5 ppm
    Environment Temperature        Power Supplied             Frequency Measure with Time Elapsed
             (°C)                       (Vac)               MCF (MHz)                  Error (ppm)
               60                       120                  896.0117                        -0.9
               50                       120                  896.0119                        -0.7
               40                       120                  896.0119                        -0.7
               30                       120                  896.0121                        -0.4
               20                       120                  896.0121                        -0.4
               10                       120                  896.0121                        -0.4
               0                        120                  896.0124                        -0.1
               -10                      120                  896.0127                        0.2
               -20                      120                  896.0129                        0.4
               -30                      120                  896.0129                        0.4


Frequency Stability Versus Input Voltage


                              Reference Frequency: 896.1025 MHz, Limit: 1.5 ppm
                                              Frequency Measure with Time Elapsed
   Power Supplied
       (Vac)                     Frequency (MHz)                               Error (ppm)

        102                          896.0119                                       -0.7
        120                          896.0121                                       -0.4
        138                          896.0127                                       0.2




Report # R0404063Rpt                       Page 18 of 18                            FCC Part 90 Test Report



Document Created: 2004-05-04 14:34:30
Document Modified: 2004-05-04 14:34:30

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC