Test Report

FCC ID: QYLF110

Test Report

Download: PDF
FCCID_2123383

                FCC Test Report                                             Report No. : FR390613-04




                              FCC Test Report
  Equipment                  : Tablet
  Brand Name                 : Getac
  Model No.                  : F110
  FCC ID                     : QYLF110
  Standard                   : 47 CFR FCC Part 15.209
  Operating Band             : 83 kHz (channel frequency 83kHz)
  FCC Classification : DCD (for Part 15 Low Power Transmitter Below 1705 kHz)
  Applicant                  : Getac Technology Corporation.
                               5F., Building A, No. 209, Sec.1, Nangang Rd.,
                               Nangang Dist., Taipei City 11568, Taiwan, R.O.C.
  Manufacturer               : Getac Technology(Kunshan)Co., LTD.
                               No. 269, No. 2 Avenue,
                               Kunshan Comprehensive Free Trade Zone,
                               Jiangsu Province, P.R.C


   The product sample received on Nov. 5, 2013 and completely tested on Nov. 07, 2013. We,
   SPORTON, would like to declare that the tested sample has been evaluated in accordance with
   the procedures given in ANSI C63.10-2009 and shown compliance with the applicable technical
   standards.

   The test results in this report apply exclusively to the tested model / sample. Without written
   approval of SPORTON INTERNATIONAL INC., the test report shall not be reproduced except in
   full.



       Reviewed by:




       Wayne Hsu / Assistant Manager




SPORTON INTERNATIONAL INC.                                           Page No.         : 1 of 26
TEL : 886-3-327-3456                                                 Report Version   : Rev. 01
FAX : 886-3-327-0973


                  FCC Test Report                                                                                       Report No. : FR390613-04


                                                        Table of Contents
1       GENERAL DESCRIPTION .................................................................................................................... 5

1.1     Information.............................................................................................................................................. 5
1.2     Accessories and Support Equipment ..................................................................................................... 6
1.3     Testing Applied Standards ..................................................................................................................... 6
1.4     Testing Location Information .................................................................................................................. 6
1.5     Measurement Uncertainty ...................................................................................................................... 7

2       TEST CONFIGURATION OF EUT ........................................................................................................ 8

2.1     The Worst Case Modulation Configuration ............................................................................................ 8
2.2     Test Channel Frequencies Configuration............................................................................................... 8
2.3     The Worst Case Measurement Configuration ........................................................................................ 8
2.4     Test Setup Diagram ............................................................................................................................... 9

3       TRANSMITTER TEST RESULT .......................................................................................................... 11

3.1     AC Power-line Conducted Emissions .................................................................................................. 11
3.2     Transmitter Radiated Emissions .......................................................................................................... 15

4       TEST EQUIPMENT AND CALIBRATION DATA ................................................................................ 26

APPENDIX A. TEST PHOTOS

APPENDIX B. PHOTOGRAPHS OF EUT




SPORTON INTERNATIONAL INC.                                                                                    Page No.                    : 2 of 26
TEL : 886-3-327-3456                                                                                          Report Version              : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                    Report No. : FR390613-04


                                   Summary of Test Result
                                     Conformance Test Specifications
Report     Ref. Std.
                            Description                Measured                         Limit               Result
Clause      Clause
 1.1.2      15.203     Antenna Requirement    Antenna connector                FCC 15.203
                                                                                                        Complied
                                              mechanism complied
  3.1       15.207     AC Power-line          [dBuV]:0.192415MHz               FCC 15.207               Complied
                       Conducted Emissions    34.75 (Margin 19.18dB) - AV
                                              52.11 (Margin 11.82dB) - QP
  3.2       15.209     Transmitter Radiated   [dBuV/m at 3m]:385.990MHz        FCC 15.209               Complied
                       Emissions              37.15 (Margin 8.85dB) - PK




SPORTON INTERNATIONAL INC.                                                  Page No.            : 3 of 26
TEL : 886-3-327-3456                                                        Report Version      : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                           Report No. : FR390613-04


                                   Revision History
     Report No.         Version              Description                            Issued Date

   FR390613-04           Rev. 01         Initial issue of report                    Nov 20, 2013




SPORTON INTERNATIONAL INC.                                         Page No.            : 4 of 26
TEL : 886-3-327-3456                                               Report Version      : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                      Report No. : FR390613-04



1         General Description
1.1       Information
1.1.1     RF General Information
                                           RF General Information
                                                   Ch. Frequency                                Field Strength
    Frequency Range          Modulation                               Channel Number
                                                        (kHz)                                     (dBuV/m)
         83 kHz                  OOK                     83                   1                        81.30
Note 1: Field strength performed peak level at 3m.

1.1.2     Antenna Information
                                              Antenna Category
      Equipment placed on the market without antennas
      Integral antenna (antenna permanently attached)
      External antenna (dedicated antennas)

1.1.3     Type of EUT
                                                   Identify EUT
EUT Serial Number               N/A
Presentation of Equipment           Production ;       Pre-Production ;    Prototype
                                                   Type of EUT
      Stand-alone
      Combined (EUT where the radio part is fully integrated within another device)
      Combined Equipment - Brand Name / Model No.:         …
      Plug-in radio (EUT intended for a variety of host systems)
      Host System - Brand Name / Model No.:        …
      Other:

1.1.4     Test Signal Duty Cycle
                                   Operated Mode for Worst Duty Cycle
      Operated normally mode for worst duty cycle
      Operated test mode for worst duty cycle
                                         Test Signal Duty Cycle (x)
      100%

1.1.5     EUT Operational Condition
Supply Voltage                   AC mains                      DC
Type of DC Source                Internal DC supply            External DC adapter           Battery


SPORTON INTERNATIONAL INC.                                                  Page No.              : 5 of 26
TEL : 886-3-327-3456                                                        Report Version        : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                     Report No. : FR390613-04

1.2       Accessories and Support Equipment
                                            Accessories Information
                                    Brand Name DELTA                      Model Name ADP-65WH BB
          AC Adapter 1
                                    Power Rating I/P: 100~240Vac, 1.5A ; O/P: 19 Vdc, 3.42A
                                    Brand Name Getac                      Model Name ADM-9019M
          AC Adapter 2
                                    Power Rating I/P: 100~240Vac, 1.5A ; O/P: 19 Vdc, 4.74A
                                    Brand Name Getac Technology Corp Model Name BP3S1P2160-S
          Li-ion Battery
                                    Power Rating 11.4Vdc, 2160mAh
              Dock                  Brand Name Getac                      Model Name F110 office dock
             Digitizer              Brand Name KYE                        Model Name T116 EMR Digitizer

1.3       Testing Applied Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the
following standards:
     47 CFR FCC Part 15
     ANSI C63.10-2009

1.4       Testing Location Information
                                                  Testing Location
                                 No. 52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang,
      HWA YA           ADD   :
                                 Tao Yuan Hsien, Taiwan, R.O.C.
                       TEL   :   886-3-327-3456        FAX   :   886-3-318-0055
   Test Condition                Test Site No.               Test Engineer              Test Environment
   AC Conduction                   CO04-HY                       David                        21°C / 48%
 Radiated Emission                03CH03-HY                      Allen                        24.9°C / 62%




SPORTON INTERNATIONAL INC.                                                   Page No.             : 6 of 26
TEL : 886-3-327-3456                                                         Report Version       : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                 Report No. : FR390613-04


1.5       Measurement Uncertainty
ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test
results be included in the report. The measurement uncertainties given below are based on a 95% confidence
level (based on a coverage factor (k=2)

                                         Measurement Uncertainty
                             Test Item                                              Uncertainty
AC power-line conducted emissions                                                    ±2.26 dB
Emission bandwidth                                                                   ±1.42 %
Unwanted emissions, conducted                  9 – 150 kHz                           ±0.38 dB
                                               0.15 – 30 MHz                         ±0.42 dB
                                               30 – 1000 MHz                         ±0.51 dB
All emissions, radiated                        9 – 150 kHz                           ±2.49 dB
                                               0.15 – 30 MHz                         ±2.28 dB
                                               30 – 1000 MHz                         ±2.56 dB
Temperature                                                                           ±0.8 °C
Humidity                                                                               ±3 %
DC and low frequency voltages                                                          ±3 %
Time                                                                                 ±1.42 %
Duty Cycle                                                                           ±1.42 %




SPORTON INTERNATIONAL INC.                                               Page No.               : 7 of 26
TEL : 886-3-327-3456                                                     Report Version         : Rev. 01
FAX : 886-3-327-0973


                  FCC Test Report                                                 Report No. : FR390613-04



2         Test Configuration of EUT
2.1       The Worst Case Modulation Configuration
                         Mode                                      Field Strength (dBuV/m at 3m)
                       Touch-Panel                                             86.11

2.2       Test Channel Frequencies Configuration
                         Mode                                     Test Channel Frequencies (kHz)
                       Touch-Panel                                            83-(F1)

2.3       The Worst Case Measurement Configuration
                          The Worst Case Mode for Following Conformance Tests
         Tests Item          AC power-line conducted emissions
         Condition           AC power-line conducted measurement for line and neutral
                             Test Voltage: 120Vac / 60Hz
      Operating Mode         Operating Mode Description
              1              AC Power & Touch Panel


                          The Worst Case Mode for Following Conformance Tests
         Tests Item          Emission Bandwidth, Field Strength of Fundamental Emissions
                             Transmitter Radiated Unwanted Emissions
       Test Condition        Radiated measurement
                                 EUT will be placed in fixed position.
                                 EUT will be placed in mobile position and operating multiple positions. EUT
                                 shall be performed three orthogonal planes. The worst planes is X.
       User Position
                                 EUT will be a hand-held or body-worn battery-powered devices and
                                 operating multiple positions. EUT shall be performed two or three
                                 orthogonal planes.
      Operating Mode             1. AC Power & Touch Panel
            Mode             Touch-Panel
                                     X Plane                     Y Plane                    Z Plane

    Orthogonal Planes of
           EUT




SPORTON INTERNATIONAL INC.                                                 Page No.          : 8 of 26
TEL : 886-3-327-3456                                                       Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                          Report No. : FR390613-04


2.4       Test Setup Diagram
                       Test Setup Diagram – AC Line Conducted Emission Test




SPORTON INTERNATIONAL INC.                                        Page No.         : 9 of 26
TEL : 886-3-327-3456                                              Report Version   : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                         Report No. : FR390613-04



                             Test Setup Diagram - Radiated Below 30MHz Test

                                       120 Vac / 60 Hz
                                          Adapter




                                                                      EUT
                                                                   (Built in Digitizer module)




                             Test Setup Diagram - Radiated Above 30MHz Test

                                      120 Vac / 60 Hz
                                         Adapter




                                                         EUT
                                               (Built in Digitizer module)




SPORTON INTERNATIONAL INC.                                                      Page No.          : 10 of 26
TEL : 886-3-327-3456                                                            Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                     Report No. : FR390613-04



3         Transmitter Test Result
3.1       AC Power-line Conducted Emissions
3.1.1     AC Power-line Conducted Emissions Limit
                                 AC Power-line Conducted Emissions Limit
    Frequency Emission (MHz)                      Quasi-Peak                              Average
               0.15-0.5                             66 - 56 *                             56 - 46 *
                 0.5-5                                 56                                     46
                  5-30                                 60                                     50
Note 1: * Decreases with the logarithm of the frequency.

3.1.2     Measuring Instruments
Refer a test equipment and calibration data table in this test report.

3.1.3     Test Procedures
                                                  Test Method
      Refer as ANSI C63.10-2009, clause 6.2 for AC power-line conducted emissions.
      If AC conducted emissions fall in operating band, then following below test method confirm final result.
           Accept measurements done with a suitable dummy load replacing the antenna under the following
           conditions:
           (1) Perform the AC line conducted tests with the antenna connected to determine compliance with
           FCC 15.207 limits outside the transmitter's fundamental emission band;
           (2) Retest with a dummy load to determine compliance with FCC 15.207 limits within the
           transmitter's fundamental emission band.
           For a device with a permanent antenna operating at or below 30 MHz, accept measurements done
           with a suitable dummy load, in lieu of the permanent antenna under the following conditions:
           (1) Perform the AC line conducted tests with the permanent antenna to determine compliance with
           the FCC 15.207 limits outside the transmitter's fundamental emission band;
           (2) Retest with a dummy load in lieu of the permanent antenna to determine compliance with the
           FCC 15.207 limits within the transmitter's fundamental emission band.




SPORTON INTERNATIONAL INC.                                                   Page No.              : 11 of 26
TEL : 886-3-327-3456                                                         Report Version        : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                          Report No. : FR390613-04


3.1.4     Test Setup
                              AC Power-line Conducted Emissions




SPORTON INTERNATIONAL INC.                                        Page No.         : 12 of 26
TEL : 886-3-327-3456                                              Report Version   : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                   Report No. : FR390613-04


3.1.5     Test Result of AC Power-line Conducted Emissions
                                 AC Power-line Conducted Emissions Result
Operating Mode               1                         Power Phase                    Neutral
Operating Function           AC Power & Touch Panel




Note 1: “>20dB” means emission levels that exceed the level of 20 dB below the applicable limit.
Note 2: “N/F” means Nothing Found emissions (No emissions were detected.)
Note 3: When emissions are in operating band over limits, retest with a dummy load for final in-band results.




SPORTON INTERNATIONAL INC.                                                 Page No.             : 13 of 26
TEL : 886-3-327-3456                                                       Report Version       : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                   Report No. : FR390613-04



                                 AC Power-line Conducted Emissions Result
Operating Mode               1                         Power Phase                    Line
Operating Function           AC Power & Touch Panel




Note 1: “>20dB” means emission levels that exceed the level of 20 dB below the applicable limit.
Note 2: “N/F” means Nothing Found emissions (No emissions were detected.)
Note 3: When emissions are in operating band over limits, retest with a dummy load for final in-band results.




SPORTON INTERNATIONAL INC.                                                 Page No.          : 14 of 26
TEL : 886-3-327-3456                                                       Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                       Report No. : FR390613-04


3.2       Transmitter Radiated Emissions
3.2.1     Transmitter Radiated Emissions Limit
                                   Transmitter Radiated Emissions Limit
Frequency Range (MHz)         Field Strength (uV/m)      Field Strength (dBuV/m)          Measure Distance (m)
        0.009~0.490                 2400/F(kHz)                  48.5 - 13.8                      300
        0.490~1.705                24000/F(kHz)                   33.8 - 23                        30
        1.705~30.0                       30                              29                        30
           30~88                        100                              40                        3
           88~216                       150                          43.5                          3
          216~960                       200                              46                        3
         Above 960                      500                              54                        3
Note 1: Test distance for frequencies at or above 30 MHz, measurements may be performed at a distance
        other than the limit distance provided they are not performed in the near field and the emissions to
        be measured can be detected by the measurement equipment. When performing measurements at
        a distance other than that specified, the results shall be extrapolated to the specified distance using
        an extrapolation factor of 20 dB/decade (inverse of linear distance for field-strength measurements,
        inverse of linear distance-squared for power-density measurements).
Note 2: Test distance for frequencies at below 30 MHz, measurements may be performed at a distance
        closer than the EUT limit distance; however, an attempt should be made to avoid making
        measurements in the near field. When performing measurements below 30 MHz at a closer distance
        than the limit distance, the results shall be extrapolated to the specified distance by either making
        measurements at a minimum of two or more distances on at least one radial to determine the proper
        extrapolation factor or by using the square of an inverse linear distance extrapolation factor (40
        dB/decade). The test report shall specify the extrapolation method used to determine compliance of
        the EUT.
Note 3: the frequency bands 9-90 kHz, 110-490 kHz measurements employing an average detector and
        other below 1GHz measurements employing a CISPR quasi-peak detector.

3.2.2     Measuring Instruments
Refer a test equipment and calibration data table in this test report.




SPORTON INTERNATIONAL INC.                                                     Page No.           : 15 of 26
TEL : 886-3-327-3456                                                           Report Version     : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                 Report No. : FR390613-04


3.2.3     Test Procedures
                                               Test Method
     Refer as ANSI C63.10, clause 6.5 for radiated emissions from 30 MHz to 1 GHz and test distance is 3m.
     Refer as ANSI C63.10, clause 6.4 for radiated emissions from below 30 MHz. The frequency bands
     9-90 kHz, 110-490 kHz measurements employing an average detector and other below 30MHz
     measurements employing a CISPR quasi-peak detector. Test distance is 3m.
     At frequencies below 30 MHz, measurements may be performed at a distance closer than that specified
     in the requirements; however, an attempt should be made to avoid making measurements in the near
     field. Pending the development of an appropriate measurement procedure for measurements performed
     below 30 MHz, when performing measurements at a closer distance than specified, the results shall be
     following below methods.
           The results shall be extrapolated to the specified distance by making measurements at a minimum
           of two distances on at least one radial to determine the proper extrapolation factor.
           The results shall be by using the square of an inverse linear distance extrapolation factor (40
           dB/decade).
     For radiated measurement. Loop antenna was rotated about the horizontal and vertical axis and the
     equipment to be measured and the test antenna shall be oriented to obtain the maximum emitted field
     strength level.
     The any unwanted emissions level shall not exceed the fundamental emission level.
     All amplitude of spurious emissions that are attenuated by more than 20 dB below the permissible value
     has no need to be reported.




SPORTON INTERNATIONAL INC.                                               Page No.           : 16 of 26
TEL : 886-3-327-3456                                                     Report Version     : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                   Report No. : FR390613-04


3.2.4     Test Setup
                                     Transmitter Radiated Emissions




Magnetic field tests shall be performed in the frequency range of 9 kHz to 30 MHz using a calibrated loop
antenna. The center of the loop shall be 1 m above the ground. Electric field tests shall be performed in the
frequency range of 30 MHz to 1000 MHz using a calibrated bi-log antenna. the antenna height shall be
varied from 1 m to 4 m.




SPORTON INTERNATIONAL INC.                                                 Page No.          : 17 of 26
TEL : 886-3-327-3456                                                       Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                  Report No. : FR390613-04


3.2.5     Transmitter Radiated Emissions (Below 30MHz)
                       Transmitter Radiated Unwanted Emissions (9 kHz –150 kHz)
Modulation Mode          Touch-Panel              Polarization             H
Operating Mode           1                        Operating Function       AC Power & Touch Panel




Note 1: “>20dB” means spurious emission levels that exceed the level of 6 dB below the applicable limit.
Note 2: “N/F” means Nothing Found spurious emissions (No spurious emissions were detected.)
Note 3: Measurement worst emissions of receive antenna polarization: V (Vertical).
Note 4: No level of unwanted emissions exceeds the level of the fundamental emission.




SPORTON INTERNATIONAL INC.                                                Page No.          : 18 of 26
TEL : 886-3-327-3456                                                      Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                  Report No. : FR390613-04



                       Transmitter Radiated Unwanted Emissions (150 kHz – 2 MHz)
Modulation Mode           Touch-Panel             Polarization             H
Operating Mode            1                       Operating Function       AC Power & Touch Panel




Note 1: “>20dB” means spurious emission levels that exceed the level of 6 dB below the applicable limit.
Note 2: “N/F” means Nothing Found spurious emissions (No spurious emissions were detected.)
Note 3: Measurement worst emissions of receive antenna polarization: V (Vertical).
Note 4: No level of unwanted emissions exceeds the level of the fundamental emission.




SPORTON INTERNATIONAL INC.                                                Page No.          : 19 of 26
TEL : 886-3-327-3456                                                      Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                  Report No. : FR390613-04



                       Transmitter Radiated Unwanted Emissions (2 MHz – 8 MHz)
Modulation Mode          Touch-Panel              Polarization             H
Operating Mode           1                        Operating Function       AC Power & Touch Panel




Note 1: “>20dB” means spurious emission levels that exceed the level of 6 dB below the applicable limit.
Note 2: “N/F” means Nothing Found spurious emissions (No spurious emissions were detected.)
Note 3: Measurement worst emissions of receive antenna polarization: V (Vertical).
Note 4: No level of unwanted emissions exceeds the level of the fundamental emission.




SPORTON INTERNATIONAL INC.                                                Page No.          : 20 of 26
TEL : 886-3-327-3456                                                      Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                  Report No. : FR390613-04



                       Transmitter Radiated Unwanted Emissions (8 MHz – 25 MHz)
Modulation Mode           Touch-Panel             Polarization             H
Operating Mode            1                       Operating Function       AC Power & Touch Panel




Note 1: “>20dB” means spurious emission levels that exceed the level of 6 dB below the applicable limit.
Note 2: “N/F” means Nothing Found spurious emissions (No spurious emissions were detected.)
Note 3: Measurement worst emissions of receive antenna polarization: V (Vertical).
Note 4: No level of unwanted emissions exceeds the level of the fundamental emission.




SPORTON INTERNATIONAL INC.                                                Page No.          : 21 of 26
TEL : 886-3-327-3456                                                      Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                  Report No. : FR390613-04



                       Transmitter Radiated Unwanted Emissions (25 MHz – 30 MHz)
Modulation Mode           Touch-Panel             Polarization             H
Operating Mode            1                       Operating Function       AC Power & Touch Panel




Note 1: “>20dB” means spurious emission levels that exceed the level of 6 dB below the applicable limit.
Note 2: “N/F” means Nothing Found spurious emissions (No spurious emissions were detected.)
Note 3: Measurement worst emissions of receive antenna polarization: V (Vertical).
Note 4: No level of unwanted emissions exceeds the level of the fundamental emission.




SPORTON INTERNATIONAL INC.                                                Page No.          : 22 of 26
TEL : 886-3-327-3456                                                      Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                  Report No. : FR390613-04


3.2.6     Transmitter Radiated Emissions (Above 30MHz)
                             Transmitter Radiated Emissions (Above 30MHz)
Modulation Mode              Touch-Panel              Test Freq. (FX)                F1
Operating Function           Transmit                 Polarization                   V




Note 1: “>20dB” means spurious emission levels that exceed the level of 6 dB below the applicable limit.
Note 2: “N/F” means Nothing Found spurious emissions (No spurious emissions were detected.)
Note 3: Measurement worst emissions of receive antenna polarization: V (Vertical).
Note 4: No level of unwanted emissions exceeds the level of the fundamental emission.




SPORTON INTERNATIONAL INC.                                                Page No.          : 23 of 26
TEL : 886-3-327-3456                                                      Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                  Report No. : FR390613-04



                             Transmitter Radiated Emissions (Above 30MHz)
Modulation Mode              Touch-Panel              Test Freq. (FX)                F1
Operating Function           Transmit                 Polarization                   H




Note 1: “>20dB” means spurious emission levels that exceed the level of 6 dB below the applicable limit.
Note 2: “N/F” means Nothing Found spurious emissions (No spurious emissions were detected.)
Note 3: Measurement worst emissions of receive antenna polarization: V (Vertical).
Note 4: No level of unwanted emissions exceeds the level of the fundamental emission.




SPORTON INTERNATIONAL INC.                                                Page No.          : 24 of 26
TEL : 886-3-327-3456                                                      Report Version    : Rev. 01
FAX : 886-3-327-0973


                FCC Test Report                                                 Report No. : FR390613-04


3.2.7     Test Result of Field Strength of Fundamental Emissions
                             Field Strength of Fundamental Emissions Result
   Modulation          Frequency      Fundamental                                             Limit
                                                       Polarization       Margin (dB)
     Mode                (MHz)       (dBuV/m)@3m                                          (dBuV/m)@3m
   Touch-Panel            F1             81.30               H               27.92            109.22
                Result                                            Complied
Note 1: Measurement worst emissions of receive antenna polarization: V (Vertical).




SPORTON INTERNATIONAL INC.                                               Page No.         : 25 of 26
TEL : 886-3-327-3456                                                     Report Version   : Rev. 01
FAX : 886-3-327-0973


                  FCC Test Report                                                                   Report No. : FR390613-04



4            Test Equipment and Calibration Data
  Instrument         Manufacturer            Model No.            Serial No.     Characteristics   Calibration Date        Remark
                                                                                                                          Conduction
EMC Receiver              R&S                ESCS 30                  100174     9kHz ~ 2.75GHz     Mar. 26, 2013
                                                                                                                          (CO04-HY)
                   SCHWARZBECK
                                                                                                                          Conduction
      LISN         MESS-ELEKTRON            NSLK 8127             8127-477       9kHz ~ 30MHz       Jan. 21, 2013
                                                                                                                          (CO04-HY)
                         IK
                                                                                                                          Conduction
RF Cable-CON       HUBER+SUHNER              RG213/U          7.61183201e+012    9kHz ~ 30MHz       Nov. 09, 2012
                                                                                                                          (CO04-HY)
                                                                                                                          Conduction
    EMI Filter         LINDGREN              LRE-2030                  2651         < 450 Hz             N/A
                                                                                                                          (CO04-HY)
Note: Calibration Interval of instruments listed above is one year.

                                                                                                    Calibration
    Instrument        Manufacturer          Model No.            Serial No.     Characteristics                          Remark
                                                                                                       Date

     3m Semi
                          SIDT                                                  30MHz ~ 1GHz                             Radiation
     Anechoic                                SAC-3M             03CH03-HY                          Dec. 01, 2012
                      FRANKONIA                                                       3m                               (03CH03-HY)
     Chamber

                                                                                                                         Radiation
     Amplifier             HP                 8447D             2944A08033      10kHz ~ 1.3GHz     May. 03, 2013
                                                                                                                       (03CH03-HY)

                                                                                                                         Radiation
     Spectrum              R&S                FSP30                   100023    9kHz ~ 30GHz       Jul. 20, 2013
                                                                                                                       (03CH03-HY)

                                                                                                                         Radiation
  Bilog Antenna       SCHAFFNER             CBL 6112D                 22237     30MHz ~ 1GHz       Sep. 21, 2013
                                                                                                                       (03CH03-HY)

                                                                                                                         Radiation
RF Cable-R03m            Jye Bao              RG142                   CB021      9kHz ~ 1GHz       Jan. 17, 2013
                                                                                                                       (03CH03-HY)

                                                                                                                         Radiation
    Turn Table       EM Electronics       EM Electronics              060615    0 ~ 360 degree         N/A
                                                                                                                       (03CH03-HY)

                                                                                                                         Radiation
  Antenna Mast             MF                MF-7802           MF780208179          1~4m               N/A
                                                                                                                       (03CH03-HY)
Note: Calibration Interval of instruments listed above is one year.

                                                                                                    Calibration
    Instrument        Manufacturer          Model No.            Serial No.     Characteristics                          Remark
                                                                                                       Date

                                                                                                                         Radiation
  Loop Antenna           TESEQ              HLA 6120                  31244     9kHz ~ 30MHz       Dec. 02, 2012
                                                                                                                       (03CH03-HY)
Note: Calibration Interval of instruments listed above is two year.




SPORTON INTERNATIONAL INC.                                                                  Page No.                : 26 of 26
TEL : 886-3-327-3456                                                                        Report Version          : Rev. 01
FAX : 886-3-327-0973



Document Created: 2019-06-24 13:13:29
Document Modified: 2019-06-24 13:13:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC