11 SAR test report

FCC ID: PY7A3880016

RF Exposure Info

Download: PDF
FCCID_1086814

                                                                                                                                                   1 (14)

                                                                                  Company Internal
                                                                                  REPORT
Prepared (also subject responsible if other)                                      No.

BA/SEMC/CCDAU Jon Kenny                                                           CCDA09: .
Approved                                                      Checked             Date                 Rev            Reference

 LD/SEMC/CCDALEC Peter Lindeborg                              PL                  090105               A              File




                                      Report issued by Accredited SAR Laboratory

                                                                             for

                                                  FCC ID: PY7A3880016 (W508)


                      Date of test:                          January 21st to January 30th 2009


                      Laboratory:                            Sony Ericsson SAR Test Laboratory
                                                             Sony Ericsson Mobile Communications AB
                                                             Maplewood, Chineham Business Park
                                                             Basingstoke, RG24 8YB,
                                                             England

                      Testing Engineer:                      Jon Kenny
                                                             Jon.Kenny@sonyericsson.com
                                                             +44 1256 77 48 91

                      Testing Approval:                      Peter Lindeborg
                                                             peter.lindeborg@sonyericsson.com
                                                             +46 10 802 43 68




Statement of Compliance
Sony Ericsson Mobile Communications AB declares under its sole responsibility that the product

                                     Sony Ericsson Type AAD-3880016-BV; FCC ID PY7A3880016; IC 4170B-A3880016

to which this declaration relates, is in conformity with the appropriate RF exposure standards recommendations and guidelines. It also declares
that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any
deviations from these standards, guidelines and recommended practices are noted below:
                                                                        (None)

            This laboratory is accredited to ISO/IEC 17025 (SWEDAC accreditation no. 1847).

            Laboratories are accredited by the Swedish Board for Accreditation and Conformity Assessment (SWEDAC) under the terms of
            Swedish legislation. The accredited laboratory activities meet the requirements in SS-EN ISO/IEC 17025 (2005). This report may not
            be reproduced other than in full, except with the prior written approval of the issuing laboratory.
            The results and statements contained herein relate only to the items tested. The names of individuals involved may be mentioned only
            in connection with the statements or results from this report.

            Sony Ericsson encourages all feedback, both positive and negative, on this report.
            © Sony Ericsson Mobile Communication AB, 2008


                                                                                                                                                                                      2 (14)

                                                                                                  Company Internal
                                                                                                  REPORT
 Prepared (also subject responsible if other)                                                     No.

 BA/SEMC/CCDAU Jon Kenny                                                                          CCDA09: .
 Approved                                                                Checked                  Date                         Rev               Reference

 LD/SEMC/CCDALEC Peter Lindeborg                                         PL                       090105                       A                 File


    Table of contents


1       INTRODUCTION .................................................................................................................................................................. 3

2       CUSTOMER DETAILS ........................................................................................................................................................ 3

3       DEVICE UNDER TEST........................................................................................................................................................ 3
    3.1         ANTENNA DESCRIPTION................................................................................................................................................... 3
    3.2         DEVICE DESCRIPTION ...................................................................................................................................................... 4
4       TEST EQUIPMENT .............................................................................................................................................................. 5
    4.1         DOSIMETRIC SYSTEM ....................................................................................................................................................... 5
    4.2         ADDITIONAL EQUIPMENT ................................................................................................................................................. 5
5       ELECTRICAL PARAMETERS ON THE TISSUE SIMULATING LIQUID .............................................................. 6

6       SYSTEM ACCURACY VERIFICATION.......................................................................................................................... 7

7       SAR MEASUREMENT UNCERTAINTY ......................................................................................................................... 8

8       TEST RESULTS .................................................................................................................................................................... 9

9       REFERENCES ..................................................................................................................................................................... 11

APPENDIX .................................................................................................................................................................................... 12
    9.1         PHOTOGRAPHS OF THE DEVICE UNDER TEST .................................................................................................................. 12
    9.2         DEVICE POSITION AT SAM TWIN PHANTOM ................................................................................................................. 13
    9.3         ATTACHMENTS ............................................................................................................................................................... 14


                                                                                                                           3 (14)

                                                                               Company Internal
                                                                               REPORT
Prepared (also subject responsible if other)                                   No.

BA/SEMC/CCDAU Jon Kenny                                                        CCDA09: .
Approved                                                        Checked        Date           Rev        Reference

LD/SEMC/CCDALEC Peter Lindeborg                                 PL             090105         A          File



                      1                        Introduction

                                               In this test report, compliance of the Sony Ericsson FCC ID: PY7A3880016 (W508)
                                               portable telephone with RF safety guidelines is demonstrated. The applicable RF
                                               safety guidelines and the SAR measurement specifications used for the test are
                                               described in the SAR Measurement Specifications of Wireless Handsets [1].


                      2                        Customer details

                                                Company Name:                Sony Ericsson Mobile
                                                                             Communications AB
                                                Address:                     2/F China Digital Kingdom
                                                                             Building, No.1 North, Beijing,
                                                                             100102, China
                                                Contact Name:                Roy Zhou



                      3                        Device Under Test


                      3.1                      Antenna Description


                                                Type                      Internal antenna
                                                Location                  Bottom of phone
                                                Main and BT
                                                                          12.5mm
                                                antennas distance
                                                Dimensions                Max length           46 mm
                                                                          Max width            14 mm
                                                Configuration             Monopole


                                                                                                                           4 (14)

                                                                        Company Internal
                                                                        REPORT
Prepared (also subject responsible if other)                           No.

BA/SEMC/CCDAU Jon Kenny                                                CCDA09: .
Approved                                                  Checked      Date                  Rev               Reference

LD/SEMC/CCDALEC Peter Lindeborg                           PL            090105               A                 File




                      3.2                      Device Description


                                 Device model                         AAD-3880016-BV
                                 Market name                          W508
                                 Serial number (EUT #)                BX900GKJ0S (#14448)
                                 Mode                                      GSM 850            GSM 1900
                                 Crest factor                                8.3                8.3
                                 Multiple access scheme                     TDMA               TDMA
                                 Channel No.                           128   190   251    512  661     885
                                                              1
                                 Measured Power Level [dBm]           32.8     32.9   32.8   30.9       30.9       30.9
                                 (#13877)
                                 Product Maximum power Level
                                        1                             33.0     33.0   33.0   31.0       31.0       31.0
                                 [dBm]
                                 Data mode                                    GPRS                      GPRS
                                 Crest factor                                  4.15                      4.15
                                                              1
                                 Measured Power Level [dBm]           29.9     29.9   29.9   28.0       27.8       27.9
                                 (#13877)
                                 Product Maximum power Level
                                        1                             30.0     30.0   30.0   28.0       28.0       28.0
                                 [dBm]
                                 Data mode                                    EDGE                      EDGE
                                 Crest factor                                  4.15                      4.15
                                                              1
                                 Measured Power Level [dBm]           27.3     27.2   27.3   26.5       26.4       26.3
                                 (#13877)
                                 Product Maximum power Level
                                        1                             27.5     27.5   27.5   26.5       26.5       26.5
                                 [dBm]
                                 Transmitting frequency range
                                                                         824.0 - 849.0             1850.0 - 1910.0
                                 [MHz]




                    GPRS Multislot class                            10
                    EDGE class                                      10
                    GPRS Capability class                           B
                    BT class and conducted power                    Class 1, 4.5 dBm
                    Prototype or production unit                    Preproduction
                    Hardware Version                                AP2.1
                    Software version                                R1DA017
                    Device category                                 Portable
                    RF exposure environment                         General population / uncontrolled


                                                                                                                           5 (14)

                                                                                 Company Internal
                                                                                 REPORT
Prepared (also subject responsible if other)                                     No.

BA/SEMC/CCDAU Jon Kenny                                                          CCDA09: .
Approved                                                      Checked            Date             Rev      Reference

LD/SEMC/CCDALEC Peter Lindeborg                               PL                 090105           A        File



                      4                        Test equipment
                      4.1                      Dosimetric system
                                               SAR measurements were made using the DASY4 professional system (software
                                               version 4.7, Build 55) with SAM twin phantom, manufactured by Schmid & Partner
                                               Engineering AG (SPEAG). The list of calibrated equipment is given below.

                                                Description                              Serial Number      Due Date
                                                DASY4 DAE3                                    448           2009-11
                                                E-field probe ET3DV6                          1610          2009-11
                                                Dipole Validation Kit, D835V2                  442          2009-12
                                                Dipole Validation Kit, D1900V2                 539          2009-12




                      4.2                      Additional equipment


                                                Description                             Inventory Number    Due Date
                                                Signal generator R&S SMY 02                   3.094         2009-04
                                                Directional coupler HP778D                   15.233           None
                                                Power meter R&S NRVD                          4.073         2009-04
                                                Power sensor R&S NRV-Z5                       4.074         2009-04
                                                Power sensor R&S NRV-Z5                       4.076         2009-04
                                                Network analyzer Agilent 8719D                2.022         2009-04
                                                Dielectric probe kit HP8507C                 14.046          Self Cal
                                                R&S CMU200                                  20011270        2009-04


                                                                                                                                    6 (14)

                                                                                Company Internal
                                                                                REPORT
Prepared (also subject responsible if other)                                    No.

BA/SEMC/CCDAU Jon Kenny                                                         CCDA09: .
Approved                                                       Checked          Date            Rev        Reference

LD/SEMC/CCDALEC Peter Lindeborg                                PL               090105          A          File



                      5                         Electrical parameters on the tissue simulating liquid

                                                Prior to conducting SAR measurements, the relative permittivity, εr, and the
                                                conductivity σ, of the tissue simulating liquids were measured with the dielectric probe
                                                kit. These values are shown in the table below. The mass density, ρ, entered into the
                                                DASY4 software is also given. Recommended limits for permittivity εr, conductivity σ
                                                and mass density ρ are also shown.

                                             f        Tissue                                    Dielectric Parameters   Density
                                                                    Measured / Recommended
                                           [MHz]       type                                        εr         σ [S/m]   ρ [g/cm³]
                                                                      Measured, 2009-01-28       40.29         0.86       1.00
                                               835    Head
                                                                         Recommended              41.5         0.90       1.00
                                                                      Measured, 2009-01-28       53.19         0.97       1.00
                                               835    Body
                                                                         Recommended              55.2         0.97       1.00
                                                                      Measured, 2009-01-21       38.02         1.47       1.00
                                               1900   Head
                                                                         Recommended              40.0         1.40       1.00
                                                                      Measured, 2009-01-29       50.66         1.54       1.00
                                               1900   Body
                                                                         Recommended              53.3         1.52       1.00


                                                                                                                                         7 (14)

                                                                                Company Internal
                                                                                REPORT
Prepared (also subject responsible if other)                                    No.

BA/SEMC/CCDAU Jon Kenny                                                         CCDA09: .
Approved                                                        Checked         Date             Rev          Reference

LD/SEMC/CCDALEC Peter Lindeborg                                 PL              090105           A            File


                      6                          System accuracy verification

                                                 A system accuracy verification of the DASY4 was performed using the dipole
                                                 validation kit listed in section 3.1. The system verification test was conducted on the
                                                 same day as the measurement of the DUT. The ambient humidity and temperature of
                                                 test facility were kept between the range 30-70% and 20.0-25.0 °C respectively.
                                                 RF noise had been measured in liquid when all RF equipment in lab was switched off.
                                                 Measured value was 0.0002 mW/g in 1g mass.


                                                                                                     Dielectric
                              f           Tissue                                  SAR [W/kg]                              Density     Liquid
                                                         Measured / Reference                       Parameters
                            [MHz]          type                                      1g                                               T[°C]
                                                                                                 εr         σ [S/m]       ρ [g/cm³]
                                                         Measured, 2009-01-28          9.84    40.29          0.86          1.00       21.9
                              835          Head
                                                              Reference                9.34     41.5          0.90          1.00       22.0
                                                         Measured, 2009-01-28          10.16   53.19          0.97          1.00       22.6
                              835              Body
                                                              Reference                9.85     55.2          0.97          1.00       22.0
                                                         Measured, 2009-01-21          38.88   38.02          1.47          1.00       21.5
                             1900          Head
                                                              Reference                41.3     40.0          1.40          1.00       22.0
                                                         Measured, 2009-01-29          40.4    50.66          1.54          1.00       21.6
                             1900              Body
                                                              Reference                41.3     53.3          1.52          1.00       22.0


                                                                                                                   8 (14)

                                                                     Company Internal
                                                                     REPORT
Prepared (also subject responsible if other)                         No.

BA/SEMC/CCDAU Jon Kenny                                              CCDA09: .
Approved                                                Checked      Date              Rev          Reference

LD/SEMC/CCDALEC Peter Lindeborg                         PL           090105            A            File


                      7                        SAR measurement uncertainty

                           SAR measurement uncertainty evaluation for Sony Ericsson PY7A3880016 (W508) phone
                                                        According to IEEE 1528

                                                                   Uncer.     Prob
                                      Uncertainty Component                           Div.    Ci       1g mass
                                                                    (%)       Dist.
                           Measurement System
                           Probe Calibration                        ±5.9       N      1       1            ±5.9
                           Axial Isotropy                           ±4.7       R      √3     0.7           ±1.9
                           Spherical Isotropy                       ±9.6       R      √3     0.7           ±3.9
                           Boundary effect                          ±1.0       R      √3      1            ±0.6
                           Probe linearity                          ±4.7       R      √3      1            ±2.7
                           Detection limit                          ±1.0       R      √3      1            ±0.6
                           Readout electronics                      ±0.3       N      1       1            ±0.3
                           Response time                            ±0.8       R      √3      1            ±0.5
                           Integration time                         ±2.6       R      √3      1            ±1.5
                           RF Ambient Conditions                    ±3.0       R      √3      1            ±1.7
                           Mech. Constraints of robot               ±0.4       R      √3      1            ±0.2
                           Probe positioning                        ±2.9       R      √3      1            ±1.7
                           Extrap, interpolation and integration    ±1.0       R      √3      1            ±0.6
                           Measurement System Uncertainty                                                  ±8.4
                           Test Sample Related
                           Device positioning                       ±3.5       N      1       1            ±3.5
                           Device holder uncertainty                ±3.5       N      1       1            ±3.5
                           Power drift                              ±5.0       R      √3      1            ±2.9
                           Test Sample Related Uncertainty                                                 ±5.5
                           Phantom and Tissue Parameters
                           Phantom uncertainty                      ±4.0       R      √3       1           ±2.3
                           Liquid conductivity (measured)           ±2.5       R      1      0.64          ±1.6
                           Liquid conductivity (target)             ±5.0       R      √3     0.64          ±1.8
                           Liquid Permittivity (measured)           ±2.5       R      1       0.6          ±1.5
                           Liquid Permittivity (target)             ±5.0       R      √3      0.6          ±1.7
                           Phantom and Tissue Parameters
                                                                                                           ±4.1
                           Uncertainty
                           Combined standard uncertainty                                                   ±10.8
                           Extended standard uncertainty (k=2)                                             ±21.6


                                                                                                                                    9 (14)

                                                                              Company Internal
                                                                              REPORT
Prepared (also subject responsible if other)                                  No.

BA/SEMC/CCDAU Jon Kenny                                                       CCDA09: .
Approved                                                      Checked         Date                Rev        Reference

LD/SEMC/CCDALEC Peter Lindeborg                               PL              090105              A          File


                      8                        Test results
                                               The ambient humidity and temperature of test facility were kept between the range
                                               30-70% and 20.0-25.0 °C respectively. A base station simulator was used to control
                                               the device during the SAR measurement. The DUT was supplied with a fully charged
                                               battery for each measurement.

                                               For head measurement, the DUT was tested with the flip open on the right-hand side,
                                               and the left-hand side of the phantom in two phone positions, cheek (touch) and tilt
                                               (cheek + 15°). The DUT was tested at the lowest, middle and highest frequencies in
                                               the transmission band. The measured 1-gram averaged SAR values of the DUT
                                               towards the head are provided in Table 1.

                                               For body measurement the DUT was tested with the flip in the closed position with
                                               the back (antenna) and front(display) towards the phantom flat section with 15 mm
                                               distance in both speech and data mode. For all modes, the device was tested at the
                                               lowest, middle and highest frequencies in the transmission band. For portable hands
                                               free (PHF) usage the Sony Ericsson head set HPB-60 was connected to the DUT.
                                               The measured 1-gram averaged SAR values of the DUT towards the body are
                                               provided in Table 2.




                                                           Measured                            Measured SAR [W/kg]
                                                                     1               Liquid
                                         Band    Channel output power Position                Left-hand   Right-hand
                                                                                     T [°C]
                                                             [dBm]                            1g mass      1g mass
                                                                         Cheek        23.9      0.53         0.63
                                                   128       32.8
                                                                          Tilt        23.9        -            -
                                         GSM                             Cheek        23.9      0.58         0.66
                                                   190       32.9
                                         850                              Tilt        23.9      0.40         0.39
                                                                         Cheek        23.9      0.75         0.74
                                                   251       32.8
                                                                          Tilt        23.9        -            -
                                                                         Cheek        22.7      0.59         0.51
                                                   512       30.9
                                                                          Tilt        22.7        -            -
                                         GSM                             Cheek        22.7      0.60         0.52
                                                   661       30.9
                                         1900                             Tilt        22.7      0.22         0.29
                                                                         Cheek        22.7      0.64         0.56
                                                   810       30.9
                                                                          Tilt        22.7        -            -


                                          Table 1: SAR measurement result for Sony Ericsson PY7A3880016 telephone at highest possible
                                                   output power. Measured towards the head.




1
    Measured output values were provided by the customer.


                                                                                                                                       10 (14)

                                                                               Company Internal
                                                                               REPORT
Prepared (also subject responsible if other)                                   No.

BA/SEMC/CCDAU Jon Kenny                                                        CCDA09: .
Approved                                                      Checked          Date                    Rev            Reference

LD/SEMC/CCDALEC Peter Lindeborg                               PL               090105                  A              File



                                                             Measured output                                               Measured
                                                                       1                                     Liquid
                                     Band         Channel        power               Position / Mode                      SAR [W/kg]
                                                                                                             T [°C]
                                                                 [dBm]                                                     1g mass
                                                                  32.8                  Back / CS            22.6            0.69
                                                    128
                                                                  29.9                 Back / GPRS           22.6            0.61
                                                                  32.9                  Back / CS            22.6            0.64
                                                    190
                                                                  29.9                 Back / GPRS           22.6            0.73
                                  GSM 850                         32.8                  Back / CS            22.6            0.53
                                                                  32.8                  Back / PHF           22.6            0.51
                                                    251           29.9                 Back / GPRS           22.6            0.81
                                                                  27.3                Back / EGPRS           22.6            0.44
                                                                  29.9                Front / GPRS           22.6            0.43
                                                                  30.9                  Back / CS            24.7            0.65
                                                    512
                                                                  28.0                 Back / GPRS           24.7            0.60
                                                                  30.9                  Back / CS            24.7            0.71
                                                    661
                                                                  27.8                 Back / GPRS           24.7            0.65
                                 GSM 1900                         30.9                  Back / CS            24.7            0.81
                                                                  30.9                  Back / PHF           24.7            0.47
                                                    810           27.9                 Back / GPRS           24.7            0.75
                                                                  26.3                Back / EGPRS           24.7            0.46
                                                                  27.9                Front / GPRS           24.7            0.25


                                          Table 2: SAR measurement result for Sony Ericsson PY7A3880016 telephone at highest possible
                                                   output power. Measured towards the body.




1
    Measured output values were provided by the customer.


                                                                                                                        11 (14)

                                                                         Company Internal
                                                                         REPORT
Prepared (also subject responsible if other)                             No.

BA/SEMC/CCDAU Jon Kenny                                                  CCDA09: .
Approved                                                  Checked        Date            Rev        Reference

LD/SEMC/CCDALEC Peter Lindeborg                           PL             090105          A          File




                      9                        References
                                               [1]   R.Plicanic. “SAR Measurement Specification of Wireless Handsets”.
                                                     Sony Ericsson SAR Test Laboratory internal document GUG/N 03:141

                                               [2]   FCC. “Evaluating Compliance with FCC Guidelines for Human Exposure to
                                                     Radio Frequency Electromagnetic Fields: Additional Information for
                                                     Evaluating Compliance of Mobile and Portable Devices with FCC Limits for
                                                     Human Exposure to Radio Frequency Emissions.” Supplement C (Edition
                                                     01-01) to OET Bulletin 65 (Edition 97- 01).

                                               [3]   IEEE. “Recommended Practice for Determining the Peak Spatial-Average
                                                     Specific Absorption Rate (SAR) in the Human Body Due to Wireless
                                                     Communications Devices: Experimental Techniques.” Std 1528-2003. June.
                                                     2003.

                                               [4]   IEC 62209-1. "Procedure to measure the Specific Absorption Rate (SAR)
                                                     for hand-held mobile wireless devices in the frequency range of 300 MHz to
                                                     3 GHz". February 2005.


                                               [5]   FCC KDB648474. "SAR Evaluation Consideration for HANDSETS with
                                                     Multiple Transmitters and Antenna", April 2008.


                                                                                                                12 (14)

                                                                     Company Internal
                                                                     REPORT
Prepared (also subject responsible if other)                         No.

BA/SEMC/CCDAU Jon Kenny                                              CCDA09: .
Approved                                                 Checked     Date             Rev           Reference

LD/SEMC/CCDALEC Peter Lindeborg                          PL          090105           A             File


                      Appendix
                      9.1                      Photographs of the device under test




                                   Front & Back Open                              Sides Open




                              Front & Back Closed                             Top & Bottom Closed


                                                                                                        13 (14)

                                                                    Company Internal
                                                                    REPORT
Prepared (also subject responsible if other)                        No.

BA/SEMC/CCDAU Jon Kenny                                             CCDA09: .
Approved                                                 Checked    Date           Rev      Reference

LD/SEMC/CCDALEC Peter Lindeborg                          PL         090105         A        File




                      9.2                      Device position at SAM Twin Phantom




                                   DUT position towards the head Flip Open: Cheek (touch) position




                               DUT position towards the head Flip Open: Tilt (touch + 15°) position


                                                                                                            14 (14)

                                                                          Company Internal
                                                                          REPORT
Prepared (also subject responsible if other)                              No.

BA/SEMC/CCDAU Jon Kenny                                                   CCDA09: .
Approved                                                   Checked        Date           Rev    Reference

LD/SEMC/CCDALEC Peter Lindeborg                            PL             090105         A      File




                                DUT position towards the body with Flip Closed and 15 mm distance




                      9.3                      Attachments

                                                 •   System validation

                                                 •   Measurement plots for head and body position

                                                 •   Probe calibration

                                                 •   Dipole calibration



Document Created: 2009-03-27 16:48:03
Document Modified: 2009-03-27 16:48:03