12371499-S2V1 Appendix B

FCC ID: PY7-54264J

Test Report

Download: PDF
FCCID_3958739

Test Laboratory: UL Verification Services Inc. SAR Lab 7                           Date: 7/10/2018

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1) @ 2600 MHz; Calibrated: 5/22/2018
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1547; Calibrated: 5/3/2018
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)

Dipole E-Field Measurement 2600MHz/2600 MHz/Hearing Aid Compatibility Test at
15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 75.71 V/m; Power Drift = 0.07 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 98.99 V/m
Near-field category: M3 (AWF 0 dB)

                                          PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          92.84 V/m        92.88 V/m   88.32 V/m
                                          Grid 4 M3        Grid 5 M3   Grid 6 M3
                                          94.04 V/m        94.63 V/m   91.65 V/m
                                          Grid 7 M3        Grid 8 M3   Grid 9 M3
                                          98.61 V/m        98.99 V/m   95.04 V/m




                      0 dB = 98.99 V/m = 39.91 dBV/m