RF Exposure info

FCC ID: PY312400219

RF Exposure Info

Download: PDF
FCCID_1918926

                                           Report No.: FR322315




         Appendix B. Maximum Permissible Exposure




FCC ID: PY312400219                       Page No.   : B1 of B3


                                                                                          Report No.: FR322315



1. Maximum Permissible Exposure
1.1. Applicable Standard

      Systems operating under the provisions of this section shall be operated in a manner that ensures
      that the public is not exposed to radio frequency energy levels in excess limit for maximum
      permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device
      has been defined as a mobile device whereby a distance of 0.2 m normally can be maintained
      between the user and the device.
      (A) Limits for Occupational / Controlled Exposure
                                                                                              Averaging Time
       Frequency Range           Electric Field      Magnetic Field     Power Density (S)
                                                                                               |E|²,|H|² or S
            (MHz)             Strength (E) (V/m)   Strength (H) (A/m)     (mW/ cm²)
                                                                                                 (minutes)
             0.3-3.0                 614                  1.63               (100)*                   6
              3.0-30               1842 / f             4.89 / f            (900 / f)*                6
             30-300                  61.4                0.163                   1.0                  6
            300-1500                                                         F/300                    6
          1500-100,000                                                            5                   6
      (B) Limits for General Population / Uncontrolled Exposure
                                                                                              Averaging Time
       Frequency Range           Electric Field      Magnetic Field     Power Density (S)
                                                                                               |E|²,|H|² or S
            (MHz)             Strength (E) (V/m)   Strength (H) (A/m)     (mW/ cm²)
                                                                                                 (minutes)
             0.3-1.34                614                  1.63               (100)*                  30
             1.34-30                824/f                2.19/f             (180/f)*                 30
             30-300                 27.5                 0.073                   0.2                 30
            300-1500                                                         F/1500                  30
          1500-100,000                                                           1.0                 30
      Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

                      30  P  G                                                 E2
      E (V/m) =                                Power Density:      Pd (W/m²) =
                          d                                                      377
      E = Electric field (V/m)
      P = Average RF output power (W)
      G = EUT Antenna numeric gain (numeric)
      d = Separation distance between radiator and human body (m)
      The formula can be changed to
              30  P  G
      Pd =
               377  d 2
      From the EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain
      of the used antenna, the RF power density can be obtained.

FCC ID: PY312400219                                                                      Page No.   : B2 of B3


                                                                                         Report No.: FR322315


1.3. Calculated Result and Limit

      For 5GHz UNII Band: Antenna Type : PCB Antenna
      Max Conducted Power for IEEE 802.11n MCS0 40MHz: 16.90 dBm
                                     Average      Average    Power Density Limit of Power
        Antenna       Antenna Gain
                                   Output Power Output Power     (S)         Density (S)  Test Result
        Gain (dBi)     (numeric)
                                      (dBm)        (mW)       (mW/cm²)       (mW/cm²)
           3.00          1.9953         16.9042        49.0252        0.019470           1         Complies




      For 5GHz ISM Band:
      Antenna Type : PCB Antenna
      Max Conducted Power for IEEE 802.11ac MCS0 VHT 20MHz: 27.19 dBm
                                     Average      Average    Power Density Limit of Power
        Directional   Antenna Gain
                                   Output Power Output Power     (S)         Density (S)  Test Result
        Gain (dBi)     (numeric)
                                      (dBm)        (mW)       (mW/cm²)       (mW/cm²)
           5.56          3.5975         27.1922        523.8625       0.375118           1         Complies
      Note: Directional gain=GANT+10log(NANT/Nss)



      For 2.4GHz Band:
      Antenna Type : PCB Antenna
      Max Conducted Power for IEEE 802.11g: 26.24 dBm
                                     Average      Average    Power Density Limit of Power
        Antenna       Antenna Gain
                                   Output Power Output Power     (S)         Density (S)  Test Result
        Gain (dBi)     (numeric)
                                      (dBm)        (mW)       (mW/cm²)       (mW/cm²)
           1.50          1.4125         26.2432        421.0413       0.118379           1         Complies


      CONCULSION:
      Both of the WLAN 2.4GHz Band and WLAN 5GHz Band can transmit simultaneously, the formula of
      calculatedthe MPE is:
      CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
      CPD = Calculation power density
      LPD = Limit of power density
      Therefore, the worst-case situation is 0.118379 / 1 + 0.375118 / 1 = 0.493497, which isless than “1”. This
      confirmed that the device comply with FCC 1.1310 MPE limit.




FCC ID: PY312400219                                                                     Page No.   : B3 of B3



Document Created: 2019-09-26 07:54:08
Document Modified: 2019-09-26 07:54:08

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC