TestRpt_RFExp_Appendix B

FCC ID: PPD-QCNFA435

RF Exposure Info

Download: PDF
FCCID_4307266

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/6


#01_WLAN2.4GHz_802.11b 1Mbps_Edge 1_Omm_Ch11

Communication System: 802.11b ; Frequency: 2462 MHz;Duty Cycle: 1:1.01
Medium: MSL_2450_190406 Medium parameters used: f = 2462 MHz; 0 = 1.979 S/m; s, = 52.565; p =
1000 kg/m*
Ambient Temperature : 23.4 °C ; Liquid Temperature : 22.4 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(7.56, 7.56, 7.56) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1399; Calibrated: 2018/11/16
— Phantom: ELI v4.0; Type: QDOVAOOIBB; Serial: 1026
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Area Scan (51x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 2.05 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 17.03 V/m; Power Drift = 0.17 dB
Peak SAR (extrapolated) = 2.68 W/kg
SAR(1 g) =1.07 W/kg; SAR(10 g) = 0.444 W/ikg
Maximum value of SAR (measured) = 2.04 W/kg

        dB
         O


        —3.00


        —6.00                 l


        —9.00


        —12.00


        —15.00        C
                    0 dB = 2.04 W/kg = 3.10 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/6


#02_WLANSGHz_802.11a 6Mbps_Edge 1_Omm_Ch52

Communication System: 802.11a ; Frequency: 5260 MHz;Duty Cycle: 1:1.054
Medium: MSL_5G_190406 Medium parameters used: f = 5260 MHz; 0 = 5.398 S/m; s, = 47.819; p = 1000
kg/m3
Ambient Temperature : 23.8 °C ; Liquid Temperature : 22.8 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.4, 4.4, 4.4) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1399; Calibrated: 2018/11/16
— Phantom: ELI v5.0; Type: QDOVAOO2AA; Serial: 1131
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Area Scan (61x121x1):; Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 1.30 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 8.131 V/m; Power Drift =—0.15 dB
Peak SAR (extrapolated) = 2.53 W/kg
SAR(1 g) = 0.567 W/kg; SAR(10 g) = 0.188 W/kg
Maximum value of SAR (measured) = 1.35 W/kg

        dB
         O


        —4.00


        —8.00


        —12.00


        16.00


        —20.00        C
                    0 dB = 1.35 W/kg = 1.30 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2019/4/6


#03_WLANSGHz_802.11a 6Mbps_Edge 1_Omm_Ch144

Communication System: 802.11a; Frequency: 5720 MHz;Duty Cycle: 1:1.054
Medium: MSL_5G_190406 Medium parameters used: f = 5720 MHz; 0 = 6.007 S/m; s, = 47.035; p = 1000
kg/m3
Ambient Temperature : 23.8 °C ; Liquid Temperature : 22.8 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.11, 4.11, 4.11) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1399; Calibrated: 2018/11/16
— Phantom: ELI v5.0; Type: QDOVAOO2AA; Serial: 1131
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Area Scan (61x121x1):; Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 2.63 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 22.17 V/m; Power Drift =—0.11 dB
Peak SAR (extrapolated) = 4.70 W/kg
SAR(1 g) = 0.993 W/kg; SAR(10 g) = 0.305 W/kg
Maximum value of SAR (measured) = 2.65 W/kg

        dB
         O


        —4.00



        —8.00                                                                          S

                                  i                               ~                l
        —12.00



        16.00


        —20.00        _
                    0 dB =2.65 W/kg = 4.23 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/6


#04_WLANSGHz_802.11a 6Mbps_Edge 1_Omm_Ch149

Communication System: 802.11a ; Frequency: 5745 MHz;Duty Cycle: 1:1.054
Medium: MSL_5G_190406 Medium parameters used : f= 5745 MHz; 0 = 6.04 S/m; g, = 47.007; p = 1000
kg/m3
Ambient Temperature : 23.8 °C ; Liquid Temperature : 22.8 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(4.11, 4.11, 4.11) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1399; Calibrated: 2018/11/16
— Phantom: ELI v5.0; Type: QDOVAOO2AA; Serial: 1131
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Area Scan (61x121x1):; Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 1.67 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 10.33 V/m; Power Drift =—0.16 dB
Peak SAR (extrapolated) = 3.70 W/kg
SAR(1 g) =0.789 W/kg; SAR(10 g) = 0.235 W/kg
Maximum value of SAR (measured) = 1.93 W/kg

        dB
         O


        —4.00


        —8.00               l

        —12.00                                                    y


        16.00


        —20.00        C
                    0 dB = 1.93 W/kg = 2.86 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab   Date: 2019/4/6


#05_Bluetooth_1Mbps_Edge 1_Omm_Ch78



Communication System: Bluetooth ; Frequency : 2480 MHz;Duty Cycle: 1:1.297
Medium: MSL_2450_190406 Medium parameters used: f = 2480 MHz; 0 = 2.004 S/m; s, = 52.541; p =
1000 kg/m*
Ambient Temperature : 23.4 °C ; Liquid Temperature : 22.4 °C

DASY5S Configuration:
— Probe: EX3DV4 — SN3931; ConvF(7.56, 7.56, 7.56) ; Calibrated: 2018/9/27
— Sensor—Surface: 1.4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1399; Calibrated: 2018/11/16
— Phantom: ELI v4.0; Type: QDOVAOOIBB; Serial: 1026
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


Area Scan (51x91x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.0341 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 2.397 V/m; Power Drift = 0.18 dB
Peak SAR (extrapolated) = 0.0440 W/kg
SAR(1 g) = 0.018 W/kg; SAR(10 g) = 0.00778 W/kg
Maximum value of SAR (measured) = 0.0346 W/kg

        dB
         O


        —2.02


        —4.05                 .


        —6.07


        —8.10


        410.12        (_—
                    0 dB = 0.0346 W/kg =—14.61 dBW/kg