RF Exposure Evaluation

FCC ID: PJMLRU500I

RF Exposure Info

Download: PDF
FCCID_4314471

                                  RF Exposure          ID LRU500i-FCC                   1/1
                        FCC ID: PJM LRU500I
                        IC: 6633A-LRU500I
                        Date : 2019-03-22




              RF Exposure Compliance Requirement
   ID LRU500i-BD-FCC / ID LRU500i-PoE-FCC / ID MAX.U500i-FCC

The maximum permissible exposure (MPE) for general population is defined as 0.6mW/cm2
( f / 1500, FCC OET Bulletin 65, Supplement B). The distance from the transmitting antenna
where the exposure level reaches the maximum permitted level is calculated using
equation (1):


                            EIRP
                     S=                                                           (1)
                          4 ⋅π ⋅ R2
       where:        S = Power density 0.6mW/cm2
                     EIRP = Power output of an isotropic antenna 4W
                     R = Distance to the centre of the radiation of the antenna


Solving equation (1) the minimum distance at which a person must keep away in a
uncontrolled exposure is


                     R = 23cm




The maximum permissible exposure (MPE) for controlled exposure is defined as 3mW/cm2
( f / 300, FCC OET Bulletin 65, Supplement B). Solving equation (1) where S = 3mW/cm2 the
minimum distance at which a person must keep away in a uncontrolled exposure is


                     R = 10,3cm




FEIG ELECTRONIC GmbH                                                                    1/1