TestReport.pdf

FCC ID: PJMCPRPOS

Test Report

Download: PDF
FCCID_2697335

                                                          TEST REPORT
                                                Test report no.: 1-0119/15-01-02

                  Testing laboratory                                                               Applicant
 CETECOM ICT Services GmbH                                                      FEIG ELECTRONIC GmbH
 Untertuerkheimer Strasse 6 – 10                                                Lange Str. 4
 66117 Saarbruecken / Germany                                                   35781 Weilburg-Waldhausen / GERMANY
 Phone:    + 49 681 5 98 - 0                                                    Phone:    +49 6471 31 09-0
 Fax:      + 49 681 5 98 - 9075                                                 Fax:      +49 6471 310-999
 Internet: http://www.cetecom.com                                               Contact: Bernhard Schüßler
 e-mail:   ict@cetecom.com                                                      e-mail:   bernhard.schuessler@feig.de
                                                                                Phone:    +49 6471 310-9435
 Accredited Testing Laboratory:
 The testing laboratory (area of testing) is accredited
 according to DIN EN ISO/IEC 17025 (2005) by the
 Deutsche Akkreditierungsstelle GmbH (DAkkS)                                                     Manufacturer
 The accreditation is valid for the scope of testing                            FEIG ELECTRONIC GmbH
 procedures as stated in the accreditation certificate with                     Lange Str. 4
 the registration number: D-PL-12076-01-00                                      35781 Weilburg-Waldhausen / GERMANY


                                                                Test standard/s
 47 CFR Part 15                Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency
                               devices
 RSS - 210 Issue 8             Spectrum Management and Telecommunications Radio Standards Specification -
                               Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment
 RSS - 210 Issue 8             RSS-210, Amendment 1 — Licence-Exempt, Low-Power Radio Apparatus
 Amendment 1                   Operating in the Television Bands (February 2015)
 For further applied test standards please refer to section 3 of this test report.


                                                                         Test Item
 Kind of test item:           RF Reader
 Model name:                  ID CPRPOS
 FCC ID:                      PJMCPRPOS
 IC:                          6633A-CPRPOS
 Frequency:                   13.56 MHz
 Technology tested:           RFID
 Antenna:                     Integrated antenna
 Power supply:                5.00 V DC by external power supply
 Temperature range:           -20°C to +70°C

This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures,
the public keys can be requested at the testing laboratory.


 Test report authorised:                                                      Test performed:
                                                                                                        cn=Andreas Luckenbill, o=CETECOM ICT
                               cn=Marco Bertolino, o=CETECOM ICT
                                                                                                        Services GmbH, ou=LUC-111202,
                               Services GmbH, ou=BTL-100826,
                                                                                                        email=andreas.luckenbill@cetecom.com,
                               email=marco.bertolino@cetecom.com, c=DE
                                                                                                        c=DE
                               2015.07.29 07:45:28 +02'00'
                                                                                                        2015.07.29 07:44:37 +02'00'

 Marco Bertolino                                                              Andreas Luckenbill
 Lab Manager                                                                  Lab Manager
 Radio Communications & EMC                                                   Radio Communications & EMC


                                                       Test report no.: 1-0119/15-01-02



1      Table of contents

1    Table of contents ............................................................................................................................................2
2    General information .......................................................................................................................................3
     2.1       Notes and disclaimer ..........................................................................................................................3
     2.2       Application details ...............................................................................................................................3
3    Test standard/s ...............................................................................................................................................4
     3.1       Measurement guidance .......................................................................................................................4
4    Test environment ............................................................................................................................................5
5    Test item ..........................................................................................................................................................5
     5.1       Additional information ........................................................................................................................5
6    Test laboratories sub-contracted .................................................................................................................5
7    Description of the test setup .........................................................................................................................6
     7.1       Shielded semi anechoic chamber ......................................................................................................7
     7.2       Shielded fully anechoic chamber ......................................................................................................8
     7.3       Conducted measurements normal and extreme conditions ...........................................................9
     7.4       AC conducted ....................................................................................................................................10
8    Measurement uncertainty ............................................................................................................................11
9    Sequence of testing .....................................................................................................................................12
     9.1       Sequence of testing 9 kHz to 30 MHz ..............................................................................................12
     9.2       Sequence of testing 30 MHz to 1 GHz .............................................................................................13
10      Summary of measurement results ..........................................................................................................14
11      Additional comments ...............................................................................................................................14
12      Measurement results ................................................................................................................................15
     12.1         Occupied bandwidth ......................................................................................................................15
     12.2         Field strength of the fundamental ................................................................................................17
     12.3         Field strength of the harmonics and spurious ...........................................................................18
     12.4         Conducted limits ............................................................................................................................21
     12.5         Frequency error .............................................................................................................................24
Annex A           Document history ..........................................................................................................................25
Annex B           Further information ........................................................................................................................25
Annex C           Accreditation Certificate ...............................................................................................................26




                                                                          Page 2 of 26


                                       Test report no.: 1-0119/15-01-02



2     General information

2.1   Notes and disclaimer
The test results of this test report relate exclusively to the test item specified in this test report. CETECOM ICT
Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test
results with regard to other specimens or samples of the type of the equipment represented by the test item.
The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report
requires the prior written approval of CETECOM ICT Services GmbH.
The testing service provided by CETECOM ICT Services GmbH has been rendered under the current "General
Terms and Conditions for CETECOM ICT Services GmbH".
CETECOM ICT Services GmbH will not be liable for any loss or damage resulting from false, inaccurate,
inappropriate or incomplete product information provided by the customer.
Under no circumstances does the CETECOM ICT Services GmbH test report include any endorsement or
warranty regarding the functionality, quality or performance of any other product or service provided.
Under no circumstances does the CETECOM ICT Services GmbH test report include or imply any product or
service warranties from CETECOM ICT Services GmbH, including, without limitation, any implied warranties of
merchantability, fitness for purpose, or non-infringement, all of which are expressly disclaimed by CETECOM ICT
Services GmbH.
All rights and remedies regarding vendor’s products and services for which CETECOM ICT Services GmbH has
prepared this test report shall be provided by the party offering such products or services and not by CETECOM
ICT Services GmbH.
In no case this test report can be considered as a Letter of Approval.

This test report is electronically signed and valid without handwritten signature. For verification of the electronic
signatures, the public keys can be requested at the testing laboratory.


2.2   Application details
Date of receipt of order:                2015-06-26
Date of receipt of test item:            2015-06-26
Start of test:                           2015-06-30
End of test:                             2015-07-08
Person(s) present during the test:       -/-




                                                   Page 3 of 26


                                    Test report no.: 1-0119/15-01-02



3     Test standard/s
Test standard       Date                  Test standard description

47 CFR Part 15      -/-                   Title 47 of the Code of Federal Regulations; Chapter I; Part 15 -
                                          Radio frequency devices
RSS - 210 Issue 8   December 2010         Spectrum Management and Telecommunications Radio
                                          Standards Specification - Licence-exempt Radio Apparatus (All
                                          Frequency Bands): Category I Equipment
RSS - 210 Issue 8   February 2015         RSS-210, Amendment 1 — Licence-Exempt, Low-Power Radio
Amendment 1                               Apparatus Operating in the Television Bands (February 2015)




3.1   Measurement guidance
Guidance                  Version         Description
                                          American national standard for methods of measurement of
ANSI C63.4-2014           -/-             radio-noise emissions from low-voltage electrical and electronic
                                          equipment in the range of 9 kHz to 40 GHz
                                          American national standard of procedures for compliance testing
ANSI C63.10-2013          -/-
                                          of unlicensed wireless devices
                          November
RSS-Gen Issue 4                           General Requirements for Compliance of Radio Apparatus
                          2014




                                              Page 4 of 26


                                          Test report no.: 1-0119/15-01-02



4      Test environment
                                    Tnom       +22 °C during room temperature tests
          Temperature:              Tmax       +70 °C during high temperature tests
                                    Tmin       -20 °C during low temperature tests

    Relative humidity content:                 46 %

       Barometric pressure:                    not relevant for this kind of testing

                                    Vnom       5.00 V    DC by external power supply
          Power supply:             Vmax       5.75 V
                                    Vmin       4.25 V


5      Test item

Kind of test item             :     RF Reader
Type identification           :     ID CPRPOS
HMN                           :     -/-
PMN                           :     ID CPRPOS
HVIN                          :     ID CPRPOS
FVIN                          :     -/-
S/N serial number             :     MAC-Adr.: 00:1C:9B:0B:00:6D
HW hardware status            :     No information available!
SW software status            :     No information available!
Frequency band                :     13.56 MHz
Type of radio transmission :
                                    Single modulated carrier
Use of frequency spectrum :
Antenna                       :     Integrated antenna
Power supply                  :     5.00 V DC by external power supply
Temperature range             :     -20°C to +70°C



5.1    Additional information
The content of the following annexes is defined in the QA. It may be that not all of the listed annexes are
necessary for this report, thus some values in between may be missing.

Test setup- and EUT-photos are included in test report:            1-0119/15-01-02_AnnexA
                                                                   1-0119/15-01-02_AnnexB
                                                                   1-0119/15-01-02_AnnexD


6      Test laboratories sub-contracted
None




                                                      Page 5 of 26


                                              Test report no.: 1-0119/15-01-02



7           Description of the test setup
Typically, the calibrations of the test apparatus are commissioned to and performed by an accredited calibration
laboratory. The calibration intervals are determined in accordance with the DIN EN ISO/IEC 17025. In addition to
the external calibrations, the laboratory executes comparison measurements with other calibrated test systems
or effective verifications. Weekly chamber inspections and range calibrations are performed. Where possible, RF
generating and signalling equipment as well as measuring receivers and analysers are connected to an external
high-precision 10 MHz reference (GPS-based or rubidium frequency standard).

In order to simplify the identification of the equipment used at some special tests, some items of test equipment
and ancillaries can be provided with an identifier or number in the equipment list below (Lab/Item).



Agenda: Kind of Calibration

    k        calibration / calibrated                            EK      limited calibration
    ne       not required (k, ev, izw, zw not required)          zw      cyclical maintenance (external cyclical
                                                                         maintenance)
    ev       periodic self verification                          izw     internal cyclical maintenance
    Ve       long-term stability recognized                      g       blocked for accredited testing
    vlkI!    Attention: extended calibration interval
    NK!      Attention: not calibrated                           *)      next calibration ordered / currently in progress




                                                          Page 6 of 26


                                                 Test report no.: 1-0119/15-01-02



7.1   Shielded semi anechoic chamber
The radiated measurements are performed in vertical and horizontal plane in the frequency range from 30 MHz
to 1 GHz in semi-anechoic chambers. The EUT is positioned on a non-conductive support with a height of 0.80
m above a conductive ground plane that covers the whole chamber. The receiving antennas are confirmed with
specifications ANSI C63.4. These antennas can be moved over the height range between 1.0 m and 4.0 m in
order to search for maximum field strength emitted from EUT. The measurement distances between EUT and
receiving antennas are indicated in the test setups for the various frequency ranges. The wanted and unwanted
emissions are received by spectrum analysers where the detector modes and resolution bandwidths over various
frequency ranges are set according to requirement ANSI C63.4 and ANSI C63.10.




SS = UR + CL + AF
(SS-signal strength; UR-voltage at the receiver; CL-loss of the cable; AF-antenna factor)

Example calculation:
SS [dBµV/m] = 12.35 [dBµV/m] + 1.90 [dB] + 16.80 [dBµV/m] = 31.05 [dBµV/m] (35.69 µV/m)


Equipment table:

       Lab /                                                                       INV. No     Kind of     Last        Next
No.            Equipment              Type             Manufact.      Serial No.
       Item                                                                        Cetecom     Calibration Calibration Calibration
1         A    Switch-Unit            3488A            HP             2719A14505   300000368   ev
               DC power supply,
2        A                            6032A            HP             2920A04466   300000580   ne
               60Vdc, 50A, 1200 W
3        A     EMI Test Receiver      ESCI 3           R&S            100083       300003312   k           26.01.2015   26.01.2016
4        A     Antenna Tower          Model 2175       ETS-Lindgren   64762        300003745   izw
               Positioning
5        A                            Model 2090       ETS-Lindgren   64672        300003746   izw
               Controller
               Turntable Interface-
6        A                            Model 105637     ETS-Lindgren   44583        300003747   izw
               Box
               TRILOG Broadband
7        A     Test-Antenna 30        VULB9163         Schwarzbeck    295          300003787   k           22.04.2014   22.04.2016
               MHz - 3 GHz




                                                            Page 7 of 26


                                                  Test report no.: 1-0119/15-01-02



7.2   Shielded fully anechoic chamber




SS = UR + CA + AF
(SS-signal strength; UR-voltage at the receiver; CA-loss of the signal path; AF-antenna factor)

Example calculation:
SS [dBµV/m] = 40.0 [dBµV/m] + (-35.8) [dB] + 32.9 [dBµV/m] = 37.1 [dBµV/m] (71.61 µV/m)


Equipment table:

       Lab /                                                                              INV. No     Kind of     Last        Next
No.            Equipment               Type             Manufact.            Serial No.
       Item                                                                               Cetecom     Calibration Calibration Calibration
               DC power supply,
1        A                             6032A            HP                   2818A03450   300001040   Ve          20.01.2015   20.01.2018
               60Vdc, 50A, 1200 W
2        A     Anechoic chamber        FAC 3/5m         MWB / TDK            87400/02     300000996   ev
3        A     Switch / Control Unit   3488A            HP                   *            300000199   ne
               Active Loop Antenna
4        A                             6502             Kontron Psychotech   8905-2342    300000256   k           24.06.2015   24.06.2017
               10 kHz to 30 MHz
               MXE EMI Receiver
5        A                             N9038A           Agilent Technologies MY51210197   300004405   k           06.03.2015   06.03.2016
               20 Hz to 26,5 GHz
               4U RF Switch
6        A                             L4491A           Agilent Technologies MY50000037   300004509   ne
               Platform




                                                             Page 8 of 26


                                             Test report no.: 1-0119/15-01-02



7.3   Conducted measurements normal and extreme conditions




Equipment table:

      Lab /                                                                           INV. No     Kind of     Last        Next
No.           Equipment            Type             Manufact.          Serial No.
      Item                                                                            Cetecom     Calibration Calibration Calibration
              Temperature Test
1       A                          VT 4002          Heraeus Voetsch    521/83761      300002326   Ve          26.09.2013   26.09.2015
              Chamber
              Signal Analyzer 40
2       A                          FSV40            R&S                101042         300004517   k           22.01.2015   22.01.2016
              GHz
              Power Supply 0-
3       A                          6632B            Agilent Technologies GB42110541   400000562   vlKI!       10.01.2013   10.01.2016
              20V, 0-5A
                                   ST18/SMAm/SMAm/                     Batch no.
4       A     RF-Cable                             Huber & Suhner                     400001184   ne          -/-          -/-
                                   72                                  699714




                                                          Page 9 of 26


                                             Test report no.: 1-0119/15-01-02



7.4   AC conducted




SS = UR + CF + VC
(SS-signal strength; UR-voltage at the receiver; CR-loss of the cable and filter; VC-correction factor of the ISN)

Example calculation:
SS [dBµV/m] = 37.62 [dBµV/m] + 9.90 [dB] + 0.23 [dB] = 47.75 [dBµV/m] (244.06 µV/m)


Equipment table:

       Lab /                                                                     INV. No     Kind of       Last          Next
No.            Equipment         Type              Manufact.        Serial No.
       Item                                                                      Cetecom     Calibration   Calibration   Calibration
1         A    Netznachbildung     ESH3-Z5         R&S              892475/017   300002209   k             17.06.2014    17.06.2016
2         A    EMI-Receiver        8542E           HP               3617A00170   300000568   k             28.01.2015    28.01.2016
               Analyzer-Reference-
                                                                    A3509 07/0
3        A     System (Harmonics ARS 16/1          SPS                           300003314   Ve            11.02.2014    11.02.2016
                                                                    0205
               and Flicker)




                                                         Page 10 of 26


                                  Test report no.: 1-0119/15-01-02



8   Measurement uncertainty

                                      Measurement uncertainty
                              Test case                                             Uncertainty
Occupied bandwidth                                                       ± 1 kHz
Field strength of the fundamental                                        ± 3 dB
Field strength of the harmonics and spurious emissions below 30 MHz      ± 3 dB
Field strength of the harmonics and spurious emissions 30 MHz to 1 GHz   ± 3 dB
Spurious emissions conducted below 30 MHz (AC conducted)                 ± 2.6 dB
Frequency error                                                          ± 10 Hz




                                             Page 11 of 26


                                  Test report no.: 1-0119/15-01-02



9     Sequence of testing

9.1   Sequence of testing 9 kHz to 30 MHz

Setup
    The equipment was setup to simulate a typical usage like descripted in the user manual or
      described by manufacturer.
    If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    If the EUT is a floor standing device, it is placed on the ground.
    Auxiliary equipment and cables were positioned to simulate normal operation conditions as
      described in ANSI C 63.4.
    The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    The measurement distance is 3 meter (see ANSI C 63.4) – see each test details
    The EUT was set into operation.

Premeasurement
    The turntable rotates from 0° to 315° with 45° steps.
    The antenna height is 1.5 meter.
    At each turntable position the analyzer sweeps with peak detection to find the maximum of all
     emissions

Final measurement
    Identified emissions during the premeasurement the software maximizes by rotating the
       turntable position (0° to 360°) and by rotating the elevation axces (0° to 360°).
    The final measurement will be done in the position (turntable and elevation) causing the highest
       emissions with QPK (QPK / see ANSI C 63.4) detector
    The final levels, frequency, measuring time, bandwidth, turntable position, correction factor,
       margin to the limit, and limit will be recorded. Also a plot with the graph of the premeasurement
       and the limit will be stored.




                                             Page 12 of 26


                                    Test report no.: 1-0119/15-01-02



9.2   Sequence of testing 30 MHz to 1 GHz

Setup
    The equipment was setup to simulate a typical usage like descripted in the user manual or
       described by manufacturer.
    If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground
       plane.
    If the EUT is a floor standing device, it is placed on the ground plane with insulation between
       both.
    Auxiliary equipment and cables were positioned to simulate normal operation conditions as
       described in ANSI C 63.4.
    The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    The measurement distance is 10 or 3 meter (see ANSI C 63.4) – see each test details
    The EUT was set into operation.
Premeasurement
    The turntable rotates from 0° to 315° with 45° steps.
    The antenna is polarized vertical and horizontal.
    The antenna height changes from 1 to 3 meter.
    At each turntable position, antenna polarization and height the analyzer sweeps three times in
       peak to find the maximum of all emissions
Final measurement
    The final measurement will be performed with minimum the six highest peaks.
    According to the maximum antenna and turntable positions of premeasurement the software
       maximize the peaks by changing turntable position (± 45°) and antenna movement between 1
       and 4 meter.
    The final measurement will be done with QP (Quasi-Peak / see ANSI C 63.4) detector with an
       EMI receiver
    The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization,
       turntable angle, correction factor, margin to the limit, and limit will be recorded. Also a plot with
       the graph of the premeasurement with marked maximum final measurements and the limit will
       be stored.




                                               Page 13 of 26


                                        Test report no.: 1-0119/15-01-02



10     Summary of measurement results

       ☒          No deviations from the technical specifications were ascertained
       ☐          There were deviations from the technical specifications ascertained
                  This test report is only a partial test report. The content and verdict of the performed test cases
       ☐          are listed below.

 TC Identifier                    Description                       Verdict           Date              Remark
                                  CFR Part 15
  RF-Testing                    RSS 210 Issue 8                    See table!     2015-07-29               -/-
                                RSS Gen Issue 4

     Test
                                            Temperature      Power source
 specification           Test case                                               C     NC    NA    NP     Remark
                                             conditions       conditions
    clause
                                                                                                                 for
     RSS Gen
      Issue 4
                    Occupied bandwidth         Nominal          Nominal         ☐      ☐      ☐     ☐ information
                                                                                                             only

  § 15.225 (a)
                    Field strength of the
    RSS 210
                        fundamental
                                               Nominal          Nominal         ☒      ☐      ☐     ☐            -/-
     (A2.6)

    § 15.209
       &            Field strength of the
 § 15.225 (b-d)        harmonics and           Nominal          Nominal         ☒      ☐      ☐     ☐            -/-
   RSS Gen                spurious
 Issue 4 (6.13)

    § 15.109        Receiver spurious
   RSS Gen         emissions and cabinet       Nominal          Nominal         ☐      ☐     ☒      ☐            -/-
 Issue 4 (6.13)          radiations

     §15.107
     §15.207
                     Conducted limits          Nominal          Nominal         ☒      ☐      ☐     ☐            -/-


  § 15.225 (a)                                Normal &         Normal &
    RSS 210        Frequency tolerance         extreme          extreme         ☒      ☐      ☐     ☐            -/-
     (A2.6)                                   conditions       conditions


Note: C = complain; NC = Not complain; NA = Not applicable; NP = Not performed



11     Additional comments
Reference documents:             None

Special test descriptions:       None

Configuration descriptions:      None




                                                   Page 14 of 26


                                    Test report no.: 1-0119/15-01-02



12       Measurement results

12.1 Occupied bandwidth
Measurement:

The emission bandwidth (x dB) is defined as the frequency range between two points, one above and one
below the carrier frequency, at which the spectral density of the emission is attenuated x dB below the
maximum in-band spectral density of the modulated signal.

                                         Measurement parameters
 Detector:                                            Peak
 Resolution bandwidth:                                1 % – 5 % of the occupied bandwidth
 Video bandwidth:                                     ≥ 3x RBW
 Trace mode:                                          Max hold
 Analyser function:                                   99 % power function
 Used equipment:                                      See chapter 7.3 - A
 Measuremnt uncertainty                               See chapter 8



Limit:

                                                      IC
                                   for RSP-100 test report coversheet only



Result:

                                         99% emission bandwidth
                                                379 kHz




                                               Page 15 of 26


                                          Test report no.: 1-0119/15-01-02



Plot:

Plot 1: 99 % emission bandwidth




                Date: 9.JUL.2015   15:10:40




                                                   Page 16 of 26


                                     Test report no.: 1-0119/15-01-02



12.2 Field strength of the fundamental
Measurement:

The maximum detected field strength for the carrier signal.

                                          Measurement parameters
 Detector:                                             Quasi peak / peak (worst case)
 Resolution bandwidth:                                 120 kHz
 Video bandwidth:                                      ≥ 3x RBW
 Trace mode:                                           Max hold
 Used equipment:                                       See chapter 7.2 - A
 Measuremnt uncertainty                                See chapter 8



Limit:

                                                   FCC & IC
             Frequency                           Field strength                                           Measurement distance
               (MHz)                                 (µV/m)                                                       (m)
          13.553 to 13.567                    15,848 (84 dBµV/m)                                                   30



Recalculation:

                                          According to ANSI C63.10
          Frequency                               Formula                                                      Correction value
                                                              𝑑nearfield                  𝑑𝑙𝑖𝑚𝑖𝑡
          13.56 MHz               FSlimit = FSmax −40 log (                ) − 20log⁡(                )            -21.39
                                                              𝑑𝑚𝑒𝑎𝑠𝑢𝑟𝑒                   𝑑𝑛𝑒𝑎𝑟𝑓𝑖𝑒𝑙𝑑




                                          According to ANSI C63.10

Result:

                                     Field strength of the fundamental
 Frequency                                                           13.56 MHz
 Distance                                                @3m                                                     @ 30 m
 Measured / calculated value – without Tag           70.1 dBµV/m                                               48.7 dBµV/m
 Measured / calculated value – with Tag              67.8 dBµV/m                                               46.4 dBµV/m




                                                 Page 17 of 26


                                     Test report no.: 1-0119/15-01-02



12.3 Field strength of the harmonics and spurious
Measurement:

The maximum detected field strength for the harmonics and spurious.

                                          Measurement parameters
                                                       Quasi peak / average or
 Detector:
                                                       peak (worst case – pre-scan)
                                                       F < 150 kHz: 200 Hz
 Resolution bandwidth:                                 150 kHz < F < 30 MHz: 9 kHz
                                                       30 MHz < F < 1 GHz: 120 kHz
                                                       F < 150 kHz: 1 kHz
 Video bandwidth:                                      150 kHz < F < 30 MHz: 100 kHz
                                                       30 MHz < F < 1 GHz: 300 kHz
 Trace mode:                                           Max hold
 Used equipment:                                       See chapter 7.1 - A, 7.2 - A, 7.3 - A
 Measuremnt uncertainty                                See chapter 8



Limit:


                                                   FCC & IC

               Frequency                        Field strength                   Measurement distance
                  (MHz)                           (dBµV/m)                              (m)
             0.009 – 0.490                       2400/F(kHz)                            300
             0.490 – 1.705                      24000/F(kHz)                             30
               1.705 – 30                     30 (29.5 dBµV/m)                           30
                 30 – 88                       100 (40 dBµV/m)                            3
                88 – 216                      150 (43.5 dBµV/m)                           3
               216 – 960                       200 (46 dBµV/m)                            3

Note:      For a reduced measurement distance, please take a look at the limit line and the ANSI C63.10-2013
           sub clause 6.4 radiated emissions from unlicensed wireless devices below 30 MHz.



Result:

                                             Detected emissions
          Frequency                                     Resolution bandwidth
                                     Detector                                            Detected value
            (MHz)                                               (kHz)
          40.7 MHz                     QP                        120                  28.6 dBµV/m @ 10m
           200 MHz                     QP                        120                  24.5 dBµV/m @ 10m




                                                 Page 18 of 26


                                                     Test report no.: 1-0119/15-01-02



Plots:

Plot 1: 9 kHz – 30 MHz, magnetic emissions, without Tag
         130
dBµV/m


         120




         110




         100




         90




         80




         70




         60




         50



                                                                                                 - Class - QPeak
         40




         30




         20




         10




          0
               9kHz                           100k                                    1M   10M           30MHz
                                                                    Frequency (MHz)




Plot 2: Spectrum mask @ 30m




                      Date: 9.JUL.2015   11:15:14




                                                              Page 19 of 26


                                                          Test report no.: 1-0119/15-01-02




Plot 3: 30 MHz – 1 GHz, vertical and horizontal polarisation



                                  60

                                  55

                                  50

                                  45

                                  40
                                                                                                               F CC _ 1 0 m_ B
                Level in dBµV/m




                                  35

                                  30

                                  25

                                  20

                                  15

                                  10

                                  5

                                  0
                                  30M             50     60    80   100M                     200     300      400       600M
                                                                         F re q u e n c y in H z




Final_Result:

                                                                            Meas.
   Frequency                          QuasiPeak     Limit       Margin                   Bandwidth   Height           Azimuth    Corr.
                                                                             Time                              Pol
     (MHz)                            (dBµV/m)    (dBµV/m)       (dB)                      (kHz)      (cm)             (deg)     (dB)
                                                                             (ms)
   40.671600                            28.61          30.00     1.39       1000.0         120.000   98.0       V       117      14.0
   199.994100                           24.47          33.50     9.03       1000.0         120.000   100.0      V       297      11.7
   350.002650                           33.20          36.00     2.80       1000.0         120.000   200.0      H       97       16.0
   449.982900                           33.01          36.00     2.99       1000.0         120.000   178.0      H       97       17.6
   499.976550                           34.62          36.00     1.38       1000.0         120.000   173.0      H       277      18.7
   549.994800                           32.07          36.00     3.93       1000.0         120.000   103.0      H       97       19.3




                                                                    Page 20 of 26


                                     Test report no.: 1-0119/15-01-02



12.4 Conducted limits
Measurement:

Measurement of the conducted spurious emissions for an intentional radiator that is designed to be connected
to the public utility (AC) power line.

                                          Measurement parameters
                                                       Quasi peak / average or
 Detector:
                                                       peak (worst case – pre-scan)
                                                       F < 150 kHz:        200 Hz
 Resolution bandwidth:
                                                       F > 150 kHz:        9 kHz
                                                       F < 150 kHz:        1 kHz
 Video bandwidth:
                                                       F > 150 kHz:        100 kHz
 Trace mode:                                           Max hold
 Used equipment:                                       See chapter 7.4 - A
 Measuremnt uncertainty                                See chapter 8



Limit:

                                                  FCC & IC
             Frequency                           Quasi-peak                              Average
               (MHz)                              (dBµV/m)                              (dBµV/m)
              0.15 – 0.5                           66 to 56*                            56 to 46*
                0.5 – 5                               56                                   46
               5 – 30.0                               60                                   50




Measurement arrangement:

The EUT housing was opened up and a twisted pair cable was soldered direct on V+ and GND of the soldering
points of the standard connector to make sure that only the DC line is connected and no other port like serial
port which is also on the standard connector.




                                                Page 21 of 26


                                                              Test report no.: 1-0119/15-01-02



Plots:

Plot 1: 150 kHz to 30 MHz, phase line

                                                                                   FCC                                                 Premeasurement
                                                                                                                                       Average limit class B
                                                                               Measurement                                             Quasi peak limit class B
                                                                                                                                       L_Peaks_fin
                                                                                Phase line                                             Average level
                                                                                                                                       Quasi peak level




                                         80.0




                                         70.0




                                         60.0




                                         50.0
                     Amplitude in dBµV




                                         40.0




                                         30.0




                                         20.0




                                         10.0




                                            0
                                           100.0K                   1.0M                        10.0M                                                100.0M
                                                                              Frequency in Hz
                                                                                                         Project ID: 1-0119/15-01-02




                                                    Quasi peak             Margin quasi
    Frequency                                                                                           Average level                                             Margin average
                                                       level                   peak
          MHz                                           dBµV                   dBµV                                 dBµV                                               dBµV

         13.562                                       47.10                   12.90                                46.85                                               3.15
         20.004                                       30.32                   29.68                                25.16                                              24.84
           25                                         30.69                   29.31                                30.38                                              19.62




                                                                           Page 22 of 26


                                                               Test report no.: 1-0119/15-01-02




Plot 2: 150 kHz to 30 MHz, neutral line

                                                                                    FCC                                                 Premeasurement
                                                                                                                                        Average limit class B
                                                                                Measurement                                             Quasi peak limit class B
                                                                                                                                        N_Peaks_fin
                                                                                 Neutral line                                           Average level
                                                                                                                                        Quasi peak level




                                          80.0




                                          70.0




                                          60.0




                                          50.0
                      Amplitude in dBµV




                                          40.0




                                          30.0




                                          20.0




                                          10.0




                                             0
                                            100.0K                   1.0M                        10.0M                                                100.0M
                                                                               Frequency in Hz
                                                                                                          Project ID: 1-0119/15-01-02




                                                     Quasi peak             Margin quasi
     Frequency                                                                                           Average level                                             Margin average
                                                        level                   peak
         MHz                                             dBµV                   dBµV                                 dBµV                                               dBµV

        13.56                                          48.21                   11.79                                47.89                                               2.11
         20                                            34.58                   25.42                                29.84                                              20.16
       25.005                                          22.96                   37.04                                21.74                                              28.26




                                                                            Page 23 of 26


                                    Test report no.: 1-0119/15-01-02



12.5 Frequency error
Measurement:

The maximum detected field strength for the spurious.

                                         Measurement parameters
 Detector:                                            Peak detector
 Resolution bandwidth:                                10 Hz
 Video bandwidth:                                     > RBW
 Trace mode:                                          Clear Write
 Used equipment:                                      See chapter 7.3 - A
 Measuremnt uncertainty                               See chapter 8



Limit:

                                                    FCC
  The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the operating
  frequency over a temperature variation of -20 degrees to +50 degrees C at normal supply voltage,
  and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a
                                temperature of 20 degrees C. (±1.356 kHz)



Result: Temperature variation

                                            Frequency tolerance
         Measured frequency
                                                  Conditions                       Result
               (MHz)
              13.5602                       -20 °C & 100% voltage                 complaint
              13.5601                       -10 °C & 100% voltage                 complaint
              13.5601                        0 °C & 100% voltage                  complaint
              13.5601                       +10 °C & 100% voltage                 complaint
              13.5601                       +20 °C & 100% voltage                 complaint
              13.5601                       +30 °C & 100% voltage                 complaint
              13.5601                       +40 °C & 100% voltage                 complaint
              13.5601                       +50 °C & 100% voltage                 complaint



Result: Voltage variation

                                            Frequency tolerance
         Measured frequency
                                                 Temperature                       Result
               (MHz)
              13.5601                       +20 °C & 85% voltage                  complaint
              13.5601                       +20 °C & 100% voltage                 complaint
              13.5601                       +20 °C & 115% voltage                 complaint




                                               Page 24 of 26


                                    Test report no.: 1-0119/15-01-02



Annex A         Document history

  Version                                 Applied changes              Date of release

                                            Initial release              2015-07-29




Annex B         Further information
Glossary

AVG        -   Average
DUT        -   Device under test
EMC        -   Electromagnetic Compatibility
EN         -   European Standard
EUT        -   Equipment under test
ETSI       -   European Telecommunications Standard Institute
FCC        -   Federal Communication Commission
FCC ID     -   Company Identifier at FCC
HW         -   Hardware
IC         -   Industry Canada
Inv. No.   -   Inventory number
N/A        -   Not applicable
PP         -   Positive peak
QP         -   Quasi peak
S/N        -   Serial number
SW         -   Software
PMN            Product marketing name
HMN            Host marketing name
HVIN           Hardware version identification number
FVIN           Firmware version identification number




                                               Page 25 of 26


                                          Test report no.: 1-0119/15-01-02



Annex C        Accreditation Certificate


              Front side of certificate                                Back side of certificate




Note:

The current certificate including annex is published on our website (see link below) or may be received
from CETECOM ICT Services on request.


http://www.cetecom.com/eu/de/cetecom-group/europa/deutschland-saarbruecken/akkreditierungen.html




                                                   Page 26 of 26



Document Created: 2015-07-29 07:45:28
Document Modified: 2015-07-29 07:45:28

© 2024 FCC.report