fcc rf report original

FCC ID: PJMCPR74

Test Report

Download: PDF
FCCID_3382199

                                                          TEST REPORT
                                              Test report no.: 1-2432/16-01-03-A

                  Testing laboratory                                                              Applicant
 CETECOM ICT Services GmbH                                                      FEIG ELECTRONIC GmbH
 Untertuerkheimer Strasse 6 – 10                                                Lange Str. 4
 66117 Saarbruecken / Germany                                                   35781 Weilburg-Waldhausen / GERMANY
 Phone:    + 49 681 5 98 - 0                                                    Phone:    +49 6471 31 09-0
 Fax:      + 49 681 5 98 - 9075                                                 Fax:      +49 6471 310-999
 Internet: http://www.cetecom.com                                               Contact: Andreas Wennrich
 e-mail:   ict@cetecom.com                                                      e-mail:   andreas.wennrich@feig.de
                                                                                Phone:    +49 6471 310-9468
 Accredited Testing Laboratory:
 The testing laboratory (area of testing) is accredited
 according to DIN EN ISO/IEC 17025 (2005) by the
 Deutsche Akkreditierungsstelle GmbH (DAkkS)                                                    Manufacturer
 The accreditation is valid for the scope of testing                            FEIG ELECTRONIC GmbH
 procedures as stated in the accreditation certificate with                     Lange Str. 4
 the registration number: D-PL-12076-01-01                                      35781 Weilburg-Waldhausen / GERMANY


                                                                Test standard/s
 47 CFR Part 15                Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency
                               devices
 RSS - 210 Issue 8             Spectrum Management and Telecommunications Radio Standards Specification -
                               Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment
 RSS - 210 Issue 8             RSS-210, Amendment 1 — Licence-Exempt, Low-Power Radio Apparatus
 Amendment 1                   Operating in the Television Bands (February 2015)
 For further applied test standards please refer to section 3 of this test report.


                                                                         Test Item
 Kind of test item:           RFID Reader
 Model name:                  CPR74
 FCC ID:                      PJMCPR74
 IC:                          6633A-CPR74
 Frequency:                   13.56 MHz
 Technology tested:           RFID
 Antenna:                     Integrated loop antenna
 Power supply:                5.00 V DC by external power supply
 Temperature range:           -25°C to +70°C

This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures,
the public keys can be requested at the testing laboratory.


 Test report authorized:                                                      Test performed:
                                                                                                      cn=Christoph Schneider, o=CETECOM ICT
                               cn=Marco Bertolino, o=CETECOM ICT                                      Services GmbH, ou=SND-120402,
                               Services GmbH, ou=BTL-150828,
                                                                                                      email=christoph.schneider@cetecom.com,
                               email=marco.bertolino@cetecom.com, c=DE
                                                                                                      c=DE
                               2016.10.25 07:46:31 +02'00'
                                                                                                      2016.10.25 07:22:26 +02'00'

 Marco Bertolino                                                              Christoph Schneider
 Lab Manager                                                                  Testing Manager
 Radio Communications & EMC                                                   Radio Communications & EMC


                Test report no.: 1-2432/16-01-03-A




1      Table of contents

1    Table of contents ............................................................................................................................................2
2    General information .......................................................................................................................................3
     2.1       Notes and disclaimer ..........................................................................................................................3
     2.2       Application details ...............................................................................................................................3
3    Test standard/s and references ....................................................................................................................4
4    Test environment ............................................................................................................................................5
5    Test item ..........................................................................................................................................................5
     5.1       General description .............................................................................................................................5
     5.2       Additional information ........................................................................................................................5
6    Test laboratories sub-contracted .................................................................................................................5
7    Description of the test setup .........................................................................................................................6
     7.1       Shielded semi anechoic chamber ......................................................................................................7
     7.2       Shielded fully anechoic chamber ......................................................................................................8
     7.3       Frequency error ...................................................................................................................................9
8    Sequence of testing .....................................................................................................................................10
     8.1       Sequence of testing radiated spurious 9 kHz to 30 MHz ...............................................................10
     8.2       Sequence of testing radiated spurious 30 MHz to 1 GHz ..............................................................11
9    Measurement uncertainty ............................................................................................................................12
10      Summary of measurement results ..........................................................................................................13
11      Additional comments ...............................................................................................................................13
12      Measurement results ................................................................................................................................14
     12.1         Occupied bandwidth ......................................................................................................................14
     12.2         Field strength of the fundamental ................................................................................................16
     12.3         Field strength of the harmonics and spurious ...........................................................................17
     12.4         Frequency error .............................................................................................................................21
13      Observations .............................................................................................................................................29
Annex A           Document history ..........................................................................................................................29
Annex B           Further information ........................................................................................................................29
Annex C           Accreditation Certificate ...............................................................................................................30




                                                                          Page 2 of 30


            Test report no.: 1-2432/16-01-03-A




2     General information

2.1   Notes and disclaimer
The test results of this test report relate exclusively to the test item specified in this test report. CETECOM ICT
Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test
results with regard to other specimens or samples of the type of the equipment represented by the test item.
The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report
requires the prior written approval of CETECOM ICT Services GmbH.
The testing service provided by CETECOM ICT Services GmbH has been rendered under the current "General
Terms and Conditions for CETECOM ICT Services GmbH".
CETECOM ICT Services GmbH will not be liable for any loss or damage resulting from false, inaccurate,
inappropriate or incomplete product information provided by the customer.
Under no circumstances does the CETECOM ICT Services GmbH test report include any endorsement or
warranty regarding the functionality, quality or performance of any other product or service provided.
Under no circumstances does the CETECOM ICT Services GmbH test report include or imply any product or
service warranties from CETECOM ICT Services GmbH, including, without limitation, any implied warranties of
merchantability, fitness for purpose, or non-infringement, all of which are expressly disclaimed by CETECOM ICT
Services GmbH.
All rights and remedies regarding vendor’s products and services for which CETECOM ICT Services GmbH has
prepared this test report shall be provided by the party offering such products or services and not by CETECOM
ICT Services GmbH.
In no case this test report can be considered as a Letter of Approval.

This test report is electronically signed and valid without handwritten signature. For verification of the electronic
signatures, the public keys can be requested at the testing laboratory.

This test report replaces the test report with the number 1-2432/16-01-03 and dated 2016-10-13.

2.2   Application details
Date of receipt of order:                2016-09-07
Date of receipt of test item:            2016-09-08
Start of test:                           2016-09-13
End of test:                             2016-09-14
Person(s) present during the test:       -/-




                                                   Page 3 of 30


           Test report no.: 1-2432/16-01-03-A




3   Test standard/s and references
Test standard           Date          Description
47 CFR Part 15          -/-           Title 47 of the Code of Federal Regulations; Chapter I; Part 15 -
                                      Radio frequency devices
RSS - 210 Issue 8       December      Spectrum Management and Telecommunications Radio Standards
                        2010          Specification - Licence-exempt Radio Apparatus (All Frequency
                                      Bands): Category I Equipment
RSS - 210 Issue 8       February      RSS-210, Amendment 1 — Licence-Exempt, Low-Power Radio
Amendment 1             2015          Apparatus Operating in the Television Bands (February 2015)


Guidance                Version       Description
                                      American national standard for methods of measurement of radio-
ANSI C63.4-2014         -/-           noise emissions from low-voltage electrical and electronic
                                      equipment in the range of 9 kHz to 40 GHz
                                      American national standard of procedures for compliance testing
ANSI C63.10-2013        -/-
                                      of unlicensed wireless devices




                                           Page 4 of 30


            Test report no.: 1-2432/16-01-03-A




4      Test environment

                                   Tnom    +24 °C during room temperature tests
Temperature                  :     Tmax    +70 °C during high temperature tests
                                   Tmin     -25 °C during low temperature tests
Relative humidity content    :             55 %
Barometric pressure          :             1021 hpa
                                   Vnom    5.00 V DC by external power supply
Power supply                 :     Vmax    5.25 V
                                   Vmin    4.75 V


5      Test item

5.1    General description

Kind of test item            :   RFID Reader
Type identification          :   CPR74
HMN                          :   -/-
PMN                          :   ID CPR74
HVIN                         :   ID CPR74
FVIN                         :   -/-
S/N serial number            :   -/-
HW hardware status           :   -/-
SW software status           :   -/-
Frequency                    :   13.56 MHz
Type of radio transmission   :
                                 single carrier
Use of frequency spectrum    :
Type of modulation           :   N1N
Number of channels           :   1
Antenna                      :   Integrated loop antenna
Power supply                 :   5.0 V DC by external power supply
Temperature range            :   -25°C to +70°C


5.2    Additional information
The content of the following annexes is defined in the QA. It may be that not all of the listed annexes are
necessary for this report, thus some values in between may be missing.

Test setup- and EUT-photos are included in test report:         1-2432/16-01-1_AnnexB
                                                                1-2432/16-01-1_AnnexD


6      Test laboratories sub-contracted
None




                                                  Page 5 of 30


                Test report no.: 1-2432/16-01-03-A




7           Description of the test setup
Typically, the calibrations of the test apparatus are commissioned to and performed by an accredited calibration
laboratory. The calibration intervals are determined in accordance with the DIN EN ISO/IEC 17025. In addition to
the external calibrations, the laboratory executes comparison measurements with other calibrated test systems
or effective verifications. Weekly chamber inspections and range calibrations are performed. Where possible, RF
generating and signaling equipment as well as measuring receivers and analyzers are connected to an external
high-precision 10 MHz reference (GPS-based or rubidium frequency standard).

In order to simplify the identification of the equipment used at some special tests, some items of test equipment
and ancillaries can be provided with an identifier or number in the equipment list below (Lab/Item).



Agenda: Kind of Calibration

    k        calibration / calibrated                            EK      limited calibration
    ne       not required (k, ev, izw, zw not required)          zw      cyclical maintenance (external cyclical
                                                                         maintenance)
    ev       periodic self verification                          izw     internal cyclical maintenance
    Ve       long-term stability recognized                      g       blocked for accredited testing
    vlkI!    Attention: extended calibration interval
    NK!      Attention: not calibrated                           *)      next calibration ordered / currently in progress




                                                          Page 6 of 30


                Test report no.: 1-2432/16-01-03-A




7.1     Shielded semi anechoic chamber
The radiated measurements are performed in vertical and horizontal plane in the frequency range from 9 kHz to
1 GHz in semi-anechoic chambers. The EUT is positioned on a non-conductive support with a height of 0.80 m
above a conductive ground plane that covers the whole chamber. The receiving antennas are confirmed with
specifications ANSI C63. These antennas can be moved over the height range between 1.0 m and 4.0 m in order
to search for maximum field strength emitted from EUT. The measurement distances between EUT and receiving
antennas are indicated in the test setups for the various frequency ranges. For each measurement, the EUT is
rotated in all three axes until the maximum field strength is received. The wanted and unwanted emissions are
received by spectrum analyzers where the detector modes and resolution bandwidths over various frequency
ranges are set according to requirement ANSI C63.




Measurement distance: tri-log antenna 10 meter

FS = UR + CL + AF
(FS-field strength; UR-voltage at the receiver; CL-loss of the cable; AF-antenna factor)

Example calculation:
FS [dBµV/m] = 12.35 [dBµV/m] + 1.90 [dB] + 16.80 [dB/m] = 31.05 [dBµV/m] (35.69 µV/m)

Equipment table:
        Lab /                                                                        INV. No  Kind of       Last        Next
  No.                Equipment             Type        Manufacturer    Serial No.
        Item                                                                         Cetecom Calibration Calibration Calibration
 1        A          Switch-Unit           3488A           HP          2719A14505   300000368    ev           -/-         -/-
                  DC power supply,
 2       A                                 6032A           HP          2920A04466   300000580      ne         -/-          -/-
                 60Vdc, 50A, 1200 W
 3       A        EMI Test Receiver        ESCI 3          R&S           100083     300003312      k      08.03.2016   08.03.2017
                 Analyzer-Reference-
                                                                       A3509 07/0
 4       A       System (Harmonics       ARS 16/1          SPS                      300003314      Ve     02.02.2016   02.02.2018
                                                                         0205
                     and Flicker)
 5       A         Antenna Tower         Model 2175    ETS-Lindgren      64762      300003745     izw         -/-          -/-
                     Positioning
 6       A                               Model 2090    ETS-Lindgren      64672      300003746     izw         -/-          -/-
                      Controller
                 Turntable Interface-
 7       A                              Model 105637   ETS-Lindgren      44583      300003747     izw         -/-          -/-
                         Box
                 TRILOG Broadband
 8       A         Test-Antenna 30       VULB9163      Schwarzbeck        295       300003787      k      25.04.2016   25.04.2018
                    MHz - 3 GHz
 9       A        Spectrum-Analyzer        FSU26           R&S           200809     300003874      k      29.01.2016   29.01.2017



                                                        Page 7 of 30


                Test report no.: 1-2432/16-01-03-A




7.2     Shielded fully anechoic chamber




Measurement distance: loop antenna 3 meter

FS = UR + CA + AF
(FS-field strength; UR-voltage at the receiver; CA-loss of the signal path; AF-antenna factor)

Example calculation:
FS [dBµV/m] = 40.0 [dBµV/m] + (-35.8) [dB] + 32.9 [dB/m] = 37.1 [dBµV/m] (71.61 µV/m)


Equipment table:

        Lab /                                                                            INV. No      Kind of       Last        Next
  No.                Equipment            Type         Manufacturer         Serial No.
        Item                                                                             Cetecom     Calibration Calibration Calibration
                  DC power supply,
 1       A                                6032A             HP             2818A03450    300001040       Ve      20.01.2015   20.01.2018
                 60Vdc, 50A, 1200 W
 2       A        Anechoic chamber       FAC 3/5m       MWB / TDK           87400/02     300000996       ev          -/-          -/-
 3       A       Switch / Control Unit    3488A           HP                   *         300000199       ne          -/-          -/-
                 Active Loop Antenna
 4       A                                 6502          EMCO/2            8905-2342     300000256       k       24.06.2015   24.06.2017
                  10 kHz to 30 MHz
                     4U RF Switch
 5       A                               L4491A     Agilent Technologies   MY50000037    300004509       ne          -/-          -/-
                       Platform
                  EMI Test Receiver
 6       A                                ESR26            R&S               101376      300005063      vlKI!    13.09.2016   13.03.2018
                    9kHz-26,5GHz




                                                         Page 8 of 30


               Test report no.: 1-2432/16-01-03-A




7.3    Frequency error




Equipment table:

       Lab /                                                                     INV. No      Kind of       Last        Next
 No.                Equipment          Type      Manufacturer       Serial No.
       Item                                                                      Cetecom     Calibration Calibration Calibration
                DC Power Supply 0
 1      A                             1108-32   Heiden Elektronik    001802      300001383       Ve      29.01.2014   29.01.2017
                      – 32V
                 Temperature Test
 2      A                             T-40/50     CTS GmbH           064023      300003540       ev      03.09.2015   03.09.2017
                     Chamber
                EMI Test Receiver 9
 3      A        kHz - 3 GHz incl.    ESPI3           R&S            101713      300004059       k       26.01.2016   26.01.2017
                    Preselector
 4      A         Loop Antenna        ESPI3     ZEG TS Steinfurt     101713      400001208       ev          -/-          -/-




                                                   Page 9 of 30


            Test report no.: 1-2432/16-01-03-A




8     Sequence of testing

8.1   Sequence of testing radiated spurious 9 kHz to 30 MHz
Setup
    The equipment is set up to simulate normal operation mode as described in the user manual or defined
      by the manufacturer.
    If the EUT is a tabletop system, a 2-axis positioner with 1.5 m height is used.
    If the EUT is a floor standing device, it is placed directly on the turn table.
    Auxiliary equipment and cables are positioned to simulate normal operation conditions as described in
      ANSI C 63.4.
    The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    Measurement distance is 3 m (see ANSI C 63.4) – see test details.
    EUT is set into operation.

Premeasurement
    The turntable rotates from 0° to 315° using 45° steps.
    The antenna height is 1.5 m.
    At each turntable position the analyzer sweeps with positive-peak detector to find the maximum of all
      emissions.

Final measurement
     Identified emissions during the premeasurement are maximized by the software by rotating the turntable
       from 0° to 360°. In case of the 2-axis positioner is used the elevation axis is also rotated from 0° to 360°.
     The final measurement is done in the position (turntable and elevation) causing the highest emissions
       with quasi-peak (as described in ANSI C 63.4).
     Final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the
       limit and limit will be recorded. A plot with the graph of the premeasurement and the limit is stored.




                                                  Page 10 of 30


            Test report no.: 1-2432/16-01-03-A




8.2   Sequence of testing radiated spurious 30 MHz to 1 GHz
Setup
    The equipment is set up to simulate normal operation mode as described in the user manual or defined
      by the manufacturer.
    If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
    If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    Auxiliary equipment and cables are positioned to simulate normal operation conditions as described in
      ANSI C 63.4.
    The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    Measurement distance is 10 m or 3 m (see ANSI C 63.4) – see test details.
    EUT is set into operation.

Premeasurement
    The turntable rotates from 0° to 315° using 45° steps.
    The antenna is polarized vertical and horizontal.
    The antenna height changes from 1 m to 3 m.
    At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to
      find the maximum of all emissions.

Final measurement
     The final measurement is performed for at least six highest peaks according to the requirements of the
       ANSI C63.4.
     Based on antenna and turntable positions at which the peak values are measured the software maximize
       the peaks by changing turntable position ± 45° and antenna height between 1 and 4 m.
     The final measurement is done with quasi-peak detector (as described in ANSI C 63.4).
     Final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle,
       correction factor, margin to the limit and limit are recorded. A plot with the graph of the premeasurement
       with marked maximum final results and the limit is stored.




                                                 Page 11 of 30


          Test report no.: 1-2432/16-01-03-A




9    Measurement uncertainty

                                       Measurement uncertainty
                          Test case                                        Uncertainty
Occupied bandwidth                                            ± used RBW
Field strength of the fundamental                             ± 3 dB
Field strength of the harmonics and spurious                  ± 3 dB
Receiver spurious emissions and cabinet radiations            ± 3 dB
Conducted limits                                              ± 2.6 dB




                                              Page 12 of 30


            Test report no.: 1-2432/16-01-03-A




10      Summary of measurement results

        ☒         No deviations from the technical specifications were ascertained
        ☐         There were deviations from the technical specifications ascertained
                  This test report is only a partial test report. The content and verdict of the performed test cases
        ☐         are listed below.

 TC Identifier                    Description                       Verdict           Date               Remark
                                  CFR Part 15
  RF-Testing                    RSS 210 Issue 8                    See table!     2016-10-25               -/-
                                RSS Gen Issue 4

      Test
                                             Temperature      Power source
 specification            Test case                                              C     NC     NA    NP     Remark
                                              conditions       conditions
    clause
   RSS Gen
    Issue 4
                    Occupied bandwidth         Nominal           Nominal         ☒      ☐     ☐     ☐            -/-


                    Field strength of the
  § 15.225 (a)
                        fundamental
                                               Nominal           Nominal         ☒      ☐     ☐     ☐            -/-


    § 15.209        Field strength of the
       &               harmonics and           Nominal           Nominal         ☒      ☐     ☐     ☐            -/-
 § 15.225 (b-d)           spurious

                    Receiver spurious
     § 15.109      emissions and cabinet       Nominal           Nominal         ☐      ☐     ☒     ☐            -/-
                         radiations

     §15.107
     §15.207
                      Conducted limits         Nominal           Nominal         ☐      ☐     ☒     ☐            -/-


                                               Normal &         Normal &
  § 15.225 (a)      Frequency tolerance         extreme          extreme         ☒      ☐     ☐     ☐            -/-
                                               conditions       conditions


Note:
 C       Compliant
 NC      Not compliant
 NA      Not applicable
 NP      Not performed



11      Additional comments
Reference documents:             None

Special test descriptions:       None

Configuration descriptions:      None




                                                   Page 13 of 30


            Test report no.: 1-2432/16-01-03-A




12       Measurement results

12.1 Occupied bandwidth
Measurement:

The emission bandwidth (x dB) is defined as the frequency range between two points, one above and one
below the carrier frequency, at which the spectral density of the emission is attenuated x dB below the
maximum in-band spectral density of the modulated signal.

                                         Measurement parameters
 Detector:                                            Peak
 Resolution bandwidth:                                1 % – 5 % of the occupied bandwidth
 Video bandwidth:                                     ≥ 3x RBW
 Trace mode:                                          Max hold
 Analyzer function:                                   99 % power function
 Used equipment:                                      See chapter 7.3 A
 Measurement uncertainty:                             See chapter 9



Limit:

                                                      IC
                                   for RSP-100 test report coversheet only



Result:

                                         99% emission bandwidth
                                               159.6 kHz




                                               Page 14 of 30


           Test report no.: 1-2432/16-01-03-A




Plot:

Plot 1: 99 % emission bandwidth
                                                                             * RBW   3    kHz    Marker      1   [T1    ]
                                                                             * VBW   10    kHz                     71.62     dBµV
                       Ref    84.4    dBµV          Att   50   dB             SWT    25    ms           13.560084000          MHz

                             Offset   -52.6   dB                                                 OBW159.600000000             kHz
                       80
                                                                                                 Temp    1   [T1    OBW]
                                                                         1                                         46.03     dBµV   A

                       70                                                                               13.481284000          MHz
                1 PK
                                                                                                 Temp    2   [T1    OBW]
                MAXH
                                                                                                                   46.20     dBµV   LVL
                       60                                                                               13.640884000          MHz



                       50       T1                                                                                      T2



                       40



                       30
                                                                                                                                    3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   20   kHz/                                    Span   200   kHz




                Date: 13.OCT.2016             10:25:22




                                                                Page 15 of 30


            Test report no.: 1-2432/16-01-03-A




12.2 Field strength of the fundamental
Measurement:

The maximum detected field strength for the carrier signal.

                                                   Measurement parameters
 Detector:                                                      Quasi peak / peak (worst case)
 Resolution bandwidth:                                          120 kHz
 Video bandwidth:                                               ≥ 3x RBW
 Trace mode:                                                    Max hold
 Used equipment:                                                See chapter 7.2 A
 Measurement uncertainty:                                       See chapter 9



Limit:

                                                               FCC & IC
             Frequency                                       Field strength                                                Measurement distance
               (MHz)                                             (µV/m)                                                            (m)
          13.553 to 13.567                                15,848 (84 dBµV/m)                                                        30



Recalculation:

                                                   According to ANSI C63.10
          Frequency                                        Formula                                                              Correction value
                                                                               𝑑nearfield                  𝑑𝑙𝑖𝑚𝑖𝑡
                                    FSlimit = FSmax −40 log (                               ) − 20log⁡(                )
                                                                               𝑑𝑚𝑒𝑎𝑠𝑢𝑟𝑒                   𝑑𝑛𝑒𝑎𝑟𝑓𝑖𝑒𝑙𝑑

                                FSlimit         is the calculation of field strength at the limit distance,
          13.56 MHz                             expressed in dBµV/m
                                                                                                                                    -21.39
                                FSmax           is the measured field strength, expressed in dBµV/m
                                dnear field     is the λ/2π distance
                                dmeasure        is the distance of the measurement point from EUT
                                dlimit          is the reference limit distance




                                                   According to ANSI C63.10

Result:

                                              Field strength of the fundamental
 Frequency                                                                 13.56 MHz
 Distance                                                   @3m                                                                  @ 30 m
 Measured / calculated value                             75.9 dBµV/m                                                          54.51 dBµV/m




                                                               Page 16 of 30


             Test report no.: 1-2432/16-01-03-A




12.3 Field strength of the harmonics and spurious
Measurement:

The maximum detected field strength for the harmonics and spurious.

                                          Measurement parameters
                                                       Quasi peak / average or
 Detector:
                                                       peak (worst case – pre-scan)
                                                       F < 150 kHz: 200 Hz
 Resolution bandwidth:                                 150 kHz < F < 30 MHz: 9 kHz
                                                       30 MHz < F < 1 GHz: 120 kHz
                                                       F < 150 kHz: 1 kHz
 Video bandwidth:                                      150 kHz < F < 30 MHz: 100 kHz
                                                       30 MHz < F < 1 GHz: 300 kHz
 Trace mode:                                           Max hold
 Used equipment:                                       See chapter 7.1 A / 7.2 A
 Measurement uncertainty:                              See chapter 9



Limit:

                                                  FCC & IC
               Frequency                        Field strength                   Measurement distance
                  (MHz)                           (dBµV/m)                              (m)
             0.009 – 0.490                       2400/F(kHz)                            300
             0.490 – 1.705                      24000/F(kHz)                             30
               1.705 – 30                     30 (29.5 dBµV/m)                           30
                 30 – 88                       100 (40 dBµV/m)                            3
                88 – 216                      150 (43.5 dBµV/m)                           3
               216 – 960                       200 (46 dBµV/m)                            3

Note:      For a reduced measurement distance, please take a look at the limit line and the ANSI C63.10-2013
           sub clause 6.4 radiated emissions from unlicensed wireless devices below 30 MHz.



Result:

                                             Detected emissions
          Frequency                                      Resolution bandwidth
                                     Detector                                            Detected value
            (MHz)                                                (kHz)
                                                  See plots!




                                                 Page 17 of 30


                      Test report no.: 1-2432/16-01-03-A




Plots:

Plot 1: 9 kHz – 30 MHz, magnetic emissions
         130
dBµV/m
         120

         110

         100

          90

          80

          70

          60

          50

                                                                                                                                                        FCC/Part 15C (15.209) - QPeak/3.0m/
          40

          30

          20

          10

           0
               9kHz                                       100k                                                1M                                  10M                      30MHz
                                                                                               Frequency




Plot 2: Spectrum mask (the limits are recalculated according to the ANSI C63.10-2013 sub clause 6.4)
                                                                                       * RBW   10   kHz    Marker   1   [T1   ]
                                                                                        VBW    30   kHz                  71.79    dBµV
                                 Ref    84.4    dBµV             Att   60   dB          SWT    20   ms         13.560000000           MHz

                                       Offset   -52.6    dB
                                 80

                                                                                   1                                                        A

                                 70
                          1 PK
                          MAXH
                                                                                                                                            LVL
                                 60


                                 FCC15225
                                 50



                                 40



                                 30
                                                                                                                                            3DB



                                 20



                                 10



                                 0



                                 -10


                                 Center   13.56    MHz                       200   kHz/                                  Span     2   MHz




                          Date: 13.OCT.2016              07:02:54




                                                                             Page 18 of 30


           Test report no.: 1-2432/16-01-03-A




Plot 3: Spectrum mask, detail
                                                                              * RBW   10    kHz   Marker   1   [T1    ]
                                                                               VBW    30    kHz                 71.72     dBµV
                        Ref    84.4    dBµV          Att   60   dB             SWT    2.5    ms       13.560400000          MHz

                              Offset   -52.6    dB
                        80

                                                                          1                                                       A

                        70
                 1 PK
                 MAXH
                                                                                                                                  LVL
                        60


                        FCC15225
                        50



                        40



                        30
                                                                                                                                  3DB



                        20



                        10



                        0



                        -10


                        Center   13.56    MHz                        20   kHz/                                 Span   200   kHz




                 Date: 13.OCT.2016              07:03:41




                                                                 Page 19 of 30


            Test report no.: 1-2432/16-01-03-A




Plot 4: 30 MHz – 1 GHz, vertical and horizontal polarization



                                 60

                                 55

                                 50

                                 45                                                                            F CC _ 1 0 m_ B

                                 40
               Level in dBµV/m




                                 35

                                 30

                                 25

                                 20

                                 15

                                 10

                                 5

                                 0
                                 30M             50 60      80 100M               200         300   400 500          8 0 0 1 ,0 5 G
                                                                        F re q u e n c y in H z



                                                                           Meas.
   Frequency                         QuasiPeak       Limit     Margin                   Bandwidth     Height              Azimuth     Corr.
                                                                            Time                               Pol
     (MHz)                           (dBµV/m)      (dBµV/m)     (dB)                      (kHz)        (cm)                (deg)      (dB)
                                                                            (ms)
   36.902850                           12.42        30.00       17.58      1000.0        120.000      178.0    V           117.0      13.9
   40.654500                           14.20        30.00       15.80      1000.0        120.000      103.0    V           269.0      14.0
   43.999800                           10.79        30.00       19.21      1000.0        120.000      101.0    V           161.0      13.9
   46.144800                           11.78        30.00       18.22      1000.0        120.000      104.0    V            53.0      13.6
   67.816800                           21.82        30.00        8.18      1000.0        120.000      272.0    V           140.0       8.9
  878.991300                           21.62        36.00       14.38      1000.0        120.000      200.0    H           320.0      23.8




                                                                      Page 20 of 30


            Test report no.: 1-2432/16-01-03-A




12.4 Frequency error
Measurement:

The maximum detected field strength for the spurious.

                                         Measurement parameters
 Detector:                                            Peak detector
 Resolution bandwidth:                                30 Hz / 100 Hz
 Video bandwidth:                                     > RBW
 Trace mode:                                          Max hold
 Used equipment:                                      See chapter 7.3 A
 Measurement uncertainty:                             See chapter 9



Limit:

                                                    FCC
 The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the operating
 frequency over a temperature variation of -20 degrees to +50 degrees C at normal supply voltage,
 and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a
                               temperature of 20 degrees C. (±1.356 kHz)



Result: Temperature variation

                                            Frequency tolerance
         Measured frequency
                                                  Conditions                      Result
               (MHz)
            13.560116                       -25 °C & 100% voltage                compliant
            13.560128                       -20 °C & 100% voltage                compliant
            13.560144                       -10 °C & 100% voltage                compliant
            13.560138                        0 °C & 100% voltage                 compliant
            13.560122                       +10 °C & 100% voltage                compliant
            13.560102                       +20 °C & 100% voltage                compliant
            13.560084                       +30 °C & 100% voltage                compliant
            13.560084                       +40 °C & 100% voltage                compliant
            13.560102                       +50 °C & 100% voltage                compliant
            13.560152                       +60 °C & 100% voltage                compliant
            13.560220                       +70 °C & 100% voltage                compliant



Result: Voltage variation

                                            Frequency tolerance
         Measured frequency
                                                 Temperature                      Result
               (MHz)
            13.560110                       +20 °C & 85% voltage                 compliant
            13.560102                       +20 °C & 100% voltage                compliant
            13.560108                       +20 °C & 115% voltage                compliant




                                               Page 21 of 30


           Test report no.: 1-2432/16-01-03-A




Plots:

Plot 1: 100% voltage; 70°C
                                                                           RBW      30    Hz       Marker   1   [T1   ]
                                                                           VBW      100    Hz                    70.81    dBµV
                       Ref    84.4    dBµV          Att   60   dB          SWT      1.15       s       13.560220000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                    A
                                                                                          1
                       70
                1 PK
                MAXH
                                                                                                                                    LVL
                       60



                       50



                       40



                       30
                                                                                                                                    3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016             09:27:06




Plot 2: 100% voltage; 60°C
                                                                           RBW      30    Hz       Marker   1   [T1   ]
                                                                           VBW      100    Hz                    70.88    dBµV
                       Ref    84.4    dBµV          Att   60   dB          SWT      1.15       s       13.560152000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                    A
                                                                                1
                       70
                1 PK
                MAXH
                                                                                                                                    LVL
                       60



                       50



                       40



                       30
                                                                                                                                    3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016             09:13:29




                                                                Page 22 of 30


           Test report no.: 1-2432/16-01-03-A




Plot 3: 100% voltage; 50°C
                                                                              RBW   30    Hz       Marker   1   [T1   ]
                                                                              VBW   100    Hz                    70.93    dBµV
                       Ref    84.4    dBµV          Att   60   dB             SWT   1.15       s       13.560102000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                    A
                                                                          1
                       70
                1 PK
                MAXH
                                                                                                                                    LVL
                       60



                       50



                       40



                       30
                                                                                                                                    3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016             08:48:51




Plot 4: 100% voltage; 40°C
                                                                              RBW   30    Hz       Marker   1   [T1   ]
                                                                              VBW   100    Hz                    71.00    dBµV
                       Ref    84.4    dBµV          Att   60   dB             SWT   1.15       s       13.560084000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                    A
                                                                      1
                       70
                1 PK
                MAXH
                                                                                                                                    LVL
                       60



                       50



                       40



                       30
                                                                                                                                    3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016             08:30:27




                                                                Page 23 of 30


           Test report no.: 1-2432/16-01-03-A




Plot 5: 100% voltage; 30°C
                                                                              RBW   30    Hz       Marker   1   [T1   ]
                                                                              VBW   100    Hz                    70.57    dBµV
                       Ref    84.4    dBµV          Att   60   dB             SWT   1.15       s       13.560084000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                    A
                                                                      1
                       70
                1 PK
                MAXH
                                                                                                                                    LVL
                       60



                       50



                       40



                       30
                                                                                                                                    3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016             08:21:02




Plot 6: 100% voltage; 20°C
                                                                              RBW   30    Hz       Marker   1   [T1   ]
                                                                              VBW   100    Hz                    70.98    dBµV
                       Ref    84.4    dBµV          Att   60   dB             SWT   1.15       s       13.560102000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                    A
                                                                          1
                       70
                1 PK
                MAXH
                                                                                                                                    LVL
                       60



                       50



                       40



                       30
                                                                                                                                    3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016             08:09:29




                                                                Page 24 of 30


           Test report no.: 1-2432/16-01-03-A




Plot 7: 100% voltage; 10°C
                                                                           RBW     30    Hz       Marker   1   [T1   ]
                                                                           VBW     100    Hz                    71.02    dBµV
                       Ref    84.4    dBµV          Att   60   dB          SWT     1.15       s       13.560122000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                   A
                                                                           1

                       70
                1 PK
                MAXH
                                                                                                                                   LVL
                       60



                       50



                       40



                       30
                                                                                                                                   3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                   Span     1   kHz




                Date: 13.OCT.2016             07:58:14




Plot 8: 100% voltage; 0°C
                                                                           RBW     30    Hz       Marker   1   [T1   ]
                                                                           VBW     100    Hz                    71.06    dBµV
                       Ref    84.4    dBµV          Att   60   dB          SWT     1.15       s       13.560138000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                   A
                                                                               1

                       70
                1 PK
                MAXH
                                                                                                                                   LVL
                       60



                       50



                       40



                       30
                                                                                                                                   3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                   Span     1   kHz




                Date: 13.OCT.2016             07:49:49




                                                                Page 25 of 30


           Test report no.: 1-2432/16-01-03-A




Plot 9: 100% voltage; -10°C
                                                                            RBW      30    Hz       Marker   1   [T1   ]
                                                                            VBW      100    Hz                    71.13    dBµV
                        Ref    84.4    dBµV          Att   60   dB          SWT      1.15       s       13.560144000           MHz

                              Offset   -52.6   dB
                        80

                                                                                                                                     A
                                                                                 1

                        70
                 1 PK
                 MAXH
                                                                                                                                     LVL
                        60



                        50



                        40



                        30
                                                                                                                                     3DB



                        20



                        10



                        0



                        -10


                        Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016              07:45:06




Plot 10: 100% voltage; -20°C
                                                                            RBW      30    Hz       Marker   1   [T1   ]
                                                                            VBW      100    Hz                    71.14    dBµV
                        Ref    84.4    dBµV          Att   60   dB          SWT      1.15       s       13.560128000           MHz

                              Offset   -52.6   dB
                        80

                                                                                                                                     A
                                                                             1

                        70
                 1 PK
                 MAXH
                                                                                                                                     LVL
                        60



                        50



                        40



                        30
                                                                                                                                     3DB



                        20



                        10



                        0



                        -10


                        Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016              07:35:04




                                                                 Page 26 of 30


           Test report no.: 1-2432/16-01-03-A




Plot 11: 100% voltage; -25°C
                                                                           RBW   30    Hz       Marker   1   [T1   ]
                                                                           VBW   100    Hz                    71.14    dBµV
                       Ref    84.4    dBµV          Att   60   dB          SWT   1.15       s       13.560116000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                 A
                                                                           1

                       70
                1 PK
                MAXH
                                                                                                                                 LVL
                       60



                       50



                       40



                       30
                                                                                                                                 3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                 Span     1   kHz




                Date: 13.OCT.2016             07:32:40




Plot 12: 115% voltage; 20°C
                                                                           RBW   30    Hz       Marker   1   [T1   ]
                                                                           VBW   100    Hz                    70.47    dBµV
                       Ref    84.4    dBµV          Att   60   dB          SWT   1.15       s       13.560108000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                 A
                                                                          1
                       70
                1 PK
                MAXH
                                                                                                                                 LVL
                       60



                       50



                       40



                       30
                                                                                                                                 3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                 Span     1   kHz




                Date: 13.OCT.2016             09:55:27




                                                                Page 27 of 30


           Test report no.: 1-2432/16-01-03-A




Plot 13: 100% voltage; 20°C
                                                                              RBW   30    Hz       Marker   1   [T1   ]
                                                                              VBW   100    Hz                    70.98    dBµV
                       Ref    84.4    dBµV          Att   60   dB             SWT   1.15       s       13.560102000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                    A
                                                                          1
                       70
                1 PK
                MAXH
                                                                                                                                    LVL
                       60



                       50



                       40



                       30
                                                                                                                                    3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016             08:09:29




Plot 12: 85% voltage; 20°C
                                                                              RBW   30    Hz       Marker   1   [T1   ]
                                                                              VBW   100    Hz                    69.71    dBµV
                       Ref    84.4    dBµV          Att   60   dB             SWT   1.15       s       13.560110000           MHz

                             Offset   -52.6   dB
                       80

                                                                                                                                    A
                                                                          1
                       70
                1 PK
                MAXH
                                                                                                                                    LVL
                       60



                       50



                       40



                       30
                                                                                                                                    3DB



                       20



                       10



                       0



                       -10


                       Center   13.560084     MHz                   100   Hz/                                    Span     1   kHz




                Date: 13.OCT.2016             09:54:51




                                                                Page 28 of 30


               Test report no.: 1-2432/16-01-03-A




13    Observations
No observations except those reported with the single test cases have been made.



Annex A           Document history

  Version                                   Applied changes                        Date of release

                                              Initial release                        2016-10-13

     A                               Updated range for power supply                  2016-10-25




Annex B           Further information
Glossary

AVG        -     Average
DUT        -     Device under test
EMC        -     Electromagnetic Compatibility
EN         -     European Standard
EUT        -     Equipment under test
ETSI       -     European Telecommunications Standard Institute
FCC        -     Federal Communication Commission
FCC ID     -     Company Identifier at FCC
HW         -     Hardware
IC         -     Industry Canada
Inv. No.   -     Inventory number
N/A        -     Not applicable
PP         -     Positive peak
QP         -     Quasi peak
S/N        -     Serial number
SW         -     Software
PMN        -     Product marketing name
HMN        -     Host marketing name
HVIN       -     Hardware version identification number
FVIN       -     Firmware version identification number




                                                 Page 29 of 30


          Test report no.: 1-2432/16-01-03-A




Annex C       Accreditation Certificate

              Front side of certificate                        Back side of certificate




Note:
The current certificate including annex can be received from CETECOM ICT Services GmbH on request.




                                           Page 30 of 30



Document Created: 2016-10-25 07:46:31
Document Modified: 2016-10-25 07:46:31

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC