User Manual

FCC ID: OXGZW30

Users Manual

Download: PDF
FCCID_2587904

                   ZW30 Smart Switch Manual
   FCC/IC
  Federal Communications Commission (FCC) Statement
  FCC Caution: Any changes or modifications not expressly approved by the party responsible for
  compliance could void the user ’s authority to operate this equipment.
  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
  conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
  interference received, including interference that may cause undesired operation.
 NOTE: This equipment has been tested and found to comply with the limits for a
 Class B digital device, pursuant to Part 15 of the FCC Rules.
 These limits are designed to provide reasonable protection against harmful interference in a
 residential installation. This equipment generates, uses and can radiate radio
 frequency energy and, if not installed and used in accordance with the
 instructions, may cause harmful interference to radio communications.
 However, there is no guarantee that interference will not occur in a particular installation.
 If this equipment does cause harmful interference to radio or television reception,
 which can be determined by turning the equipment off and on, the user is encouraged to
 try to correct the interference by one or more of the followingmeasures:
 -- Reorient or relocate the receiving antenna.
 -- Increase the separation between the equipment and receiver.
 -- Connect the equipment into an outlet on a circuit different from that to which the
 receiver is connected.
 -- Consult the dealer or an experienced radio/TV technician for help.                                           In-wall smart switch
  IC Caution:
  This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
  to the following two conditions: (1) this device may not cause interference, and (2) this device must
  accept any interference, including interference that may cause undesired
  operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage;
 (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionn
ement.


   WARRANTY
 Show Home Products warrants this product to be free from manufacturing defects for
 a period of two years from the original date of consumer purchase. This warranty is limited
 to the repair or replacement of this product only and does not extend to consequential or
 incidental damage to other products that may be used with this product.

 This warranty is in lieu of all other warranties, expressed or implied. Some states do not
 allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
 of incidental or consequential damage, so the above limitations may not apply to you.

 This warranty gives you specific rights, and you may also have other rights which vary from
 state to state. if the unit should prove defective within the warranty period.


                                                                                      WARNING
                                                                                    RISK OF FIRE
   SPECIFICATIONS                                                                   RISK OF ELECTRICAL SHOCK
                                                                                    RISK OF BURNS
                                                                                    CONTROLLING APPLIANCES:
 Model:ZW30                                                                         EXERCISE EXTREME CAUTION WHEN USING Z-WAVE
 Power: 120 VAC, 60 Hz.                                                             DEVICES TO CONTROL APPLIANCES. OPERATION
 Signal (Frequency): 908.42 MHz.                                                    OF THE Z-WAVE DEVICE MAY BE IN A DIFFERENT
 Maximum Loads: 600W, incandescent,                                                 ROOM THAN THE CONTROLLED APPLIANCE, ALSO AN
 ½ HP Motor or 1800W (15A) Resistive                                                UNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG
 Range: Up to 100 feet line of sight between the                                    BUTTON ON THE REMOTE IS PRESSED. Z-WAVE DEVICES
 Wireless Controller and the closest Z-Wave                                         MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED
 receiver module.                                                                   EVENT PROGRAMMING. DEPENDING UPON THE APPLI-
 Operating Temperature Range: 32-104° F (0-40° C)                                   ANCE, THESE UNATTENDED OR UNINTENTIONAL OP-
 For indoor use only.                                                               ERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS
 Specifications subject to change without notice                                    CONDITION. FOR THESE REASONS, WE RECOMMEND
 due to continuing product improvement                                              DO NOT RETURN THIS PRODUCT TO THE STORE
                                                                                    THE FOLLOWING:
  Website www.ishowlights.com                                                       DO NOT USE Z-WAVE DEVICES TO CONTROL ELECTRIC
                                                                                    HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRES-
                                                                                    ENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR
                                                                                    UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.


                                                          Getting To Know Your New Z-Wave Device
                                                         Turn ON/OFF manually or remotely via the Z-Wave controller
                                                         • Can be Included in multiple Groups and Scenes
                                                         • May be used in single pole installation or with up to two GE Add-on switches in
                                                            3-way or 4-way wiring configurations
                                                         • Compatible with all incandescent and CFL/LED bulbs
                                                         • Interchangeable Paddle switch — White & light almond paddle in package
                                                         • Uses a standard, decorative-size wall plate for single gang installations
                                                            ( wall plate not included)
                                                         • Blue LED indicates switch location in a dark room
                                                         • Z-Wave Certified for simple pairing and integrated home automation
                                                         • Screw Terminal Installation — requires wiring connections for Line (Hot), Load,
                                                           Neutral, and Ground. Traveler wire required for 3-way or 4-way installation




                                                                                                              A. Top Rocker — (Press &release to turn
                                                                                                              Dimmer on,press & hold
                                                                                                               increases brightness)
                                                                                                              B. Bottom Rocker — (Press& release
                                                                                                              to to turn switch off)
                                                                                                               C. Ground (Green/Bare)
                                                                                                               D. Load (Black) E. Line (Black)
                                                                                                              F. Traveler (Red/Other)
                                                                                                              G.Neutral (White)


   Single, Dual And Triple Gang Boxes
   When installing the In-wall Smart Dimmer in multiple gang boxes it may be necessary to break off one or both sides of the scored
   tabs on the front yoke.This will affect the electrical rating of the switch (see specifications for details)




                                                        WARNING — SHOCK HAZARD
                                                        Turn OFF the power to the branch circuit for the switch and lighting fixture at
                                                        the service panel. All wiring connections must be made with the POWER OFF
                                                        to avoid personal injury and/or damage to the switch.
                                                        This device is intended for installation in accordance with the National Electric
                                                        Code and local regulations in the United States, or the Canadian Electrical
                                                        Code and local regulations in Canada. If you are unsure or
                                                        uncomfortable about performing this installation consult a qualified electrician.

Multi-switch wiring                                                           6. Connect the green copper ground wire to the GROUND terminal.
For 3-way installations, please refer to Add-on Switch manual                 7. Connect the black wire that goes to the light to the terminal marked LOAD.
Single switch wiring                                                          8. Connect the black wire that comes from the electrical service panel (Hot)
Before you start; you may wish to change the paddle to match                     to the terminal marked LINE.
your wall plate or decore. Please proceed to section 5.                       9. Connect the white wire to the neutral terminal (use jumper wire if needed).
1. Shut off power to the circuit at circuit breaker or fuse box.              Note: The Traveler terminal is only used for 3-way or 4-way wiring and should
IMPORTANT! Verify power is OFF to switch box before continuing.               remain insulated if the switch installed in a 2-way system (one switch & one load).
2. Remove wall plate.                                                         10. Insert Switch into the switch box being careful not to pinch or crush wires.
3. Remove the switch mounting screws.                                         11. Secure the Switch to the box using the supplied screws.
4. There are up to five screw terminals on the switch; these are marked       12. Mount the wall plate.
A. LINE (Hot) — Black (connected to power)                                    13. Reapply power to the circuit at fuse box or circuit breaker and test the system.
B. Neutral — White                                                            Basic Operation
C. LOAD — Black (connected to lighting)                                       The connected light can be turned ON/OFF in two ways,
D. GROUND — Green/Bare                                                        1. Manually from the front panel of the In-wall Switch
E. TRAVELER — Red/Other (only in 3-way installations)                         2. Remotely with a Z-Wave Controller
Match these screw terminals to the wires connected to the existing switch. Manual Control
5. Observe Important Wiring Information                                       The Front Panel Rocker Switch allows the user to:
IMPORTANT!: This Dimmer is rated for and intended to                          Turn ON/OFF the connected fixture.
only be used with copper wire.                                                To turn the connected fixture ON: Press and release the top of the rocker.
Wire Gauge Requirements                                                       To turn the connected fixture OFF: Press and release the bottom of the rocker.
Use 14 AWG or larger wires suitable for at least 80° C for supplying
 Line (HOT), Load,Neutral, Ground and Traveler connections.
Wire strip length:
For attachment to screw terminals: Strip insulation 1" (25mm)
For attachment using the enclosure’s holes: Strip insulation 5/8"(16mm)
UL specifies that the tightening torque for the screws is 12 Kgf-cm.
                                                                        Linking your device
                                                                        1. Follow the instructions for your Z-wave certified controller to include a device to
                                                                           the Z-wave network.
                                                                        2. Once the controller is ready to include your device, press and release the Program
                                                                         Button to include it in the network.
                                                                        Note: Your controller may need to be within 10 feet of the device to be included.
                                                                        3. Once your controller has confirmed that the device has been included, refresh
                                                                        the Z-wave network to optimize performance.Please reference the controller,
                                                                        gateway’s manual for instructions.Now you have complete control to turn your
                                                                        fixture ON/OFF according to groups, scenes, schedules and interactive automations
                                                                        programmed by your controller.If your Z-wave certified controller features Remote
                                                                        Access, you can now control your fixture from your mobile devices.
                                                                        Note: To exclude and reset the device, follow the instructions provided
                                                                        by your Z-Wave controller.

                              To Change Color Of The Paddle
                              This step is optional. Before you start you may want to change the color of the paddle to match your wallplate or decor.
                              1. Lift the Air Gap tab at the base of the paddle.
                              2. Push side tabs in on one side and then the other to release paddle. Lift the cover up and off.
                              3. Simply put the new paddle onto the switch by inserting the air gap and side tabs and snapping securely into place.

                              Once this step has been completed please return to section 3.



Document Created: 2015-04-15 15:51:17
Document Modified: 2015-04-15 15:51:17

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC