Alignment procedure

FCC ID: OOLUKL60104

Parts List/Tune Up Info

Download: PDF
FCCID_129610

Applicant:                                                                                  FCC ID:

Ericsson Microwave Systems AB                                                     OOLULKL60104

                                                                                           Exhibit 10

                                    ALIGNMENT PROCEDURE




Alignment Procedure

All the necessary adjustments are set in the factory and will need no further adjustments in the field.
(Oscillators, waveguide filters are tuned to the right frequencies, Tx amplifier are set and verified
not exceed maximum output levels, etc.)

Actual channel frequency as well actual transmitter output power are selected, through software,
during installation and commisioning.

If a failure occurs, causing for instance the RF oscillator to go out of phase-lock, the transmitter will
automatically shut down.




                           © 2000 Ericsson Microwave Systems AB


                      10-1      MINI-LINK BAS




            Technical Data

EN/LZB 111 0542 P2B          Technical Description


MINI-LINK BAS                                      10-2




10.1            System Parameters
                               The MINI-LINK BAS operates with the following high frequency
                               parameters.



10.1.1          Frequency Range
                               The following channel spacing feature is available: 28 MHz for 37.5
                               Mbps.
                               The RAU is available for different frequency channel arrangements,
                               according to FCC, ITU-R and ETSI recommendations. The
                               MINI-LINK BAS frequency bands are listed below.


               Frequency bands            Frequency range     Duplex distance     Channel spacing
                    (GHz)                      (GHz)              (MHz)               (MHz)

                  ETSI 26 GHz                24.5-26.5              1008                    28
               LMDS "A" 28 GHz               27.5-28.35             420                     28
               LMDS “B” 31 GHz               31,0-31,30             225                     28



                             ETSI 26 GHz frequency plan, related to CEPT rec. TR 13-02

               Channel number              Duplex (MHz)         Downlink Tx              Uplink Tx

                        1                       1008             24.563 GHz          25.571 GHz
                        2                       1008             24.591 GHz          25.599 GHz
                        3                       1008             24.619 GHz          25.627 GHz
                        4                       1008             24.647 GHz          25.655 GHz
                        5                       1008             24.675 GHz          25.683 GHz
                        6                       1008             24.703 GHz          25.711 GHz
                        7                       1008             24.731 GHz          25.739 GHz
                        8                       1008             24.759 GHz          25.767 GHz
                        9                       1008             24.787 GHz          25.795 GHz
                        10                      1008             24.815 GHz          25.823 GHz
                        11                      1008             24.843 GHz          25.851 GHz
                        12                      1008             24.871 GHz          25.879 GHz
                        13                      1008             24.899 GHz          25.907 GHz
                        14                      1008             24.927 GHz          25.935 GHz
                        15                      1008             24.955 GHz          25.963 GHz



Technical Description                                                            EN/LZB 111 0542 P2B


                                                 10-3                                  MINI-LINK BAS



                           ETSI 26 GHz frequency plan, related to CEPT rec. TR 13-02

             Channel number              Duplex (MHz)         Downlink Tx              Uplink Tx

                      16                      1008             24.983 GHz          25.991 GHz
                      17                      1008             25.011 GHz          26.019 GHz
                      18                      1008             25.039 GHz          26.047 GHz
                      19                      1008             25.067 GHz          26.075 GHz
                      20                      1008             25.095 GHz          26.103 GHz
                      21                      1008             25.123 GHz          26.131 GHz
                      22                      1008             25.151 GHz          26.159 GHz
                      23                      1008             25.179 GHz          26.187 GHz
                      24                      1008             25.207 GHz          26.215 GHz
                      25                      1008             25.235 GHz          26.243 GHz
                      26                      1008             25.263 GHz          26.271 GHz
                      27                      1008             25.291 GHz          26.299 GHz
                      28                      1008             25.319 GHz          26.327 GHz
                      29                      1008             25.347 GHz          26.355 GHz
                      30                      1008             25.375 GHz          26.383 GHz
                      31                      1008             25.403 GHz          26.411 GHz
                      32                      1008             25.431 GHz          26.439 GHz




EN/LZB 111 0542 P2B                                                             Technical Description


MINI-LINK BAS                                 10-4




                                            LMDS "A" 28 GHz frequency plan

                        Channel number        Duplex (MHz)      Downlink Tx      Uplink Tx

                                1                420 MHz        27.519 GHz      27.939 GHz
                                2                420 MHz        27.547 GHz      27.967 GHz
                                3                420 MHz        27.575 GHz      27.995 GHz
                                4                420 MHz        27.603 GHz      28.023 GHz
                                5                420 MHz        27.631 GHz      28.051 GHz
                                6                420 MHz        27.659 GHz      28.079 GHz
                                7                420 MHz        27.687 GHz      28.107 GHz
                                8                420 MHz        27.715 GHz      28.135 GHz
                                9                420 MHz        27.743 GHz      28.163 GHz
                                10               420 MHz        27.771 GHz      28.191 GHz
                                11               420 MHz        27.799 GHz      28.219 GHz
                                12               420 MHz        27.827 GHz      28.247 GHz
                                13               420 MHz        27.855 GHz      28.275 GHz
                                14               420 MHz        27.883 GHz      28.303 GHz
                                15               420 MHz        27.911 GHz      28.331 GHz



                                           LMDS “B” 31 GHz frequency plan

                        Channel number        Duplex (MHz)      Downlink Tx      Uplink Tx

                                1                225 MHz        31,021 GHz      31,251 GHz
                                2                225 MHz        31,049 GHz      31,279 GHz




10.1.2          Transmitter Performance
                        Transmitter output power has the following typical values with the
                        guaranteed value within parentheses:
                        •   23(21) dBm for ETSI 26 GHz
                        •   23(21) dBm for LMDS "A" 28 GHz
                        •   23(21) dBm for LMDS "B" 31 GHz

                        Note:        Filter loss is included.



Technical Description                                                     EN/LZB 111 0542 P2B


                                                                10-5                                              MINI-LINK BAS



                      Frequency Tolerances
                      The frequency stability is +/- 10 ppm from nominal centre frequency.
                      Both Tx and Rx oscillators (VCO) are phase locked loop controlled.

                      Output Spectrum
                      The transmitter spectrum stays in all operating conditions within the
                      given mask centred at nominal channel frequency. There is also a
                      typical output spectrum reported, see Figure 10–1.



                                                 0
                                                                                                     Spectrum Mask
                                                                                                     Typical Output Spectrum


                                                -10



                                                -20
                          Spectrum Mask [dBc]




                                                -30



                                                -40



                                                -50




                                                -60
                                                   0       10          20    30            40    50            60              70
                                                                                  f-fo [MHz]



                      Figure 10–1 Transmitter Mask


                       Capacity Power density level (dB)                                        Frequency (MHz)

                         Mbps                          A0         A1        A2            f1    f2           f3          f4         f5
                         37.5                          0          -23       -45          11     19          25           45         70




EN/LZB 111 0542 P2B                                                                                        Technical Description


MINI-LINK BAS                                   10-6




10.1.3          Receiver Performance
                        Receiver input threshold has the following typical values with the
                        guaranteed values within parentheses:

                                                                -3                  -6                          -9
                                BER                   BER 10                 BER 10                  BER 10

                         Power Level (dBm)            -82 (-81)              -78 (-77)               -75 (-74)

                        Co-Channel Interference
                        The limits of co-channel interference are given in the table below with
                        the guaranteed values on brackets.

                               BER limit               C/I for 1dB increase of C/I for 3dB increase of
                                                               BER limit               BER limit
                                       -3
                                  10                            17 (18) dB                     14 (15) dB
                                       -6
                                  10                            21 (23) dB                     17 (19) dB




                        Adjacent Channel Interference
                        The limits of adjacent channel interference are given in the table
                        below with the guaranteed values on brackets.

                           Channel          BER limit          C/I for 1dB           C/I for 3dB
                           spacing                        increase of BER limit increase of BER limit
                                                 -3
                           28 MHz             10                     -6 (-5) dB                    -9 (-8) dB
                                                 -6
                                              10                     -2 (0) dB                     -6 (-4) dB


                        Signature
                        Reference delay is 6.3 ns.
                        Values between brackets for non-minimum phase.

                                                                        -3                               -6
                                                            BER 10                             BER 10
                               Traffic
                              capacity
                                                Notch depth Signature Notch depth Signature
                               Mbps
                                                   (dB)     width (MHz)  (dB)     width (MHz)

                                37.5                  14 (17)          24 (20)           11 (14)         24 (21)




Technical Description                                                                      EN/LZB 111 0542 P2B


                                         10-7                               MINI-LINK BAS




10.1.4        Transmission Technology
                      Downlink TDM and Uplink TDMA are in accordance with the ETSI
                      standards EN 301 213 Part 1 and Part 3.
                      •   Maximum number of sectors for Hub is 4, with a 90°-sector
                          antenna.
                      Note:     For added capacity it is possible to have more overlapped
                                sectors, for example, up to 6 sector for each Hub, using
                                different channel frequencies.

                      •   Frequency reuse: 2.
                      •   Modulation Scheme: C-QPSK.
                      •   Spectral Efficiency:1.3 bps/Hz.
                      •   System power level control: overall dynamic range is greater than
                          60 dB, for semi fade compensation and path loss compensation.
                          Compensated fade slope up to 50 dB/sec.
                          Transmitter Power Control (ATPC) dynamic range is 35 dB.
                      •   Path coverage calculations are based on the following standards:
                          − Flat multipath fading according to ITU-R Rec.          P. 530-
                              7, sec. 2.3;
                          − Rain fading according to ITU-R Recommendations P. 530-7,
                              sec. 2.4;
                          − Selective multipath fading according to ITU-R Rec. P. 530-7,
                              sec. 5.1;
                          − Atmospheric absorption according to ITU-R Rec. P. 676-3
                              annex 2.




EN/LZB 111 0542 P2B                                                      Technical Description


MINI-LINK BAS                               10-8




10.2            Intermediate Frequency
                        IF Transmitting
                        350 MHz

                        IF Transmitting Power Level
                        •   Modem output:           -2 dBm - +2 dBm
                        •   Radio input:            -20 dBm - +2 dBm.

                        IF Receiving Power Level
                        •   Modem input:            -70 dBm - +10 dBm
                        •   Radio output:          -50 dBm - +5 dBm

                        IF Receiving
                        Approximately 1 GHz, after the first down conversion, and 140 MHz,
                        after the second down conversion.

                        IF Receiving Power Level
                        -45 dBm - 0 dBm.




Technical Description                                                   EN/LZB 111 0542 P2B


                                          10-9                                 MINI-LINK BAS




10.3          System Features
                      The MINI-LINK BAS is featured by the following system parameters.


                      Maximum Configuration
                      •    AT/RN Number:                64
                      •    Max. RN/R-AAS Number: 6
                      •    Max. AT/CP Number:           capacity verified up to 128 AT/CP
                      •    Max. CP/EM Number:           10


                      Maximum Connections
                      1.   ET
                      •    4096 VPC available, whose 15 are available for VC connections
                      • 1792 VCC per VPC on 15 VPC
                      Note:   Default configuration: NNI Mode

                      2.   CP
                      Maximum connections per CP: 4500.
                      3.   PVC/AT
                      Maximum connections per PVC/AT:          256.


                      Max. Cell Capacity Over Air Interface
                      78,000 cells per second, in Downlink


                      R-AAS Switching Throughput
                      530 Mbps


                      Supported Ethernet Functionality
                      IP services are carried transparently through the system using a self-
                      learning bridge at the AT.
                      The number of terminals (PCs, workstations), connected to one AT, is
                      limited to 256 due to the MAC addresses number stored in the self-
                      learning bridge.


                      Supported ATM Service Classes
                      UBR and CBR



EN/LZB 111 0542 P2B                                                        Technical Description


MINI-LINK BAS                               10-10



                        Granularity
                        ATM cell


                        User Interfaces
                        POTS, BRA ISDN, PRA ISDN, V.11, V.24, X.21 and Token Ring
                        can be fulfilled with an external user multiplexer/equipment. The
                        following services are directly supported by system interfaces:
                        •    Ethernet 10BaseT built-in
                        •    Ethernet 10/100 BaseT (plug in card)
                        •    E1 unstructured G.703
                        •    T1 unstructured ANSI T1.403, G.703
                        E1/T1 service interface units are configurable via system parameters.


                        Network Interfaces
                        •    E1 unstructured G.703
                        •    T1 unstructured ANSI T1.403, G.703
                        •    E3 ITU-T G.703, G.804, G.832
                        •    optical OC-3/STM-1 S1-1 ITU-T G.957, G.707, I.432.1
                        •    DS3 ITU-T G.703 120 Ohm, G.804, G832
                        E1/T1, OC-3/STM-1, E3/DS3 units are configurable via system
                        parameters.

                        Total Sign-On Time
                        Sign-on at initial start (average time)
                        •    10 AT population       in 6 min;
                        •    30 AT population       in 8 min;
                        •    64 AT population       in 15 min;
                        Sign-on after the sign-off per single AT
                        •    11-14s including traffic set-up.
                        Fading for the whole AT population in the considered sector
                        •    deep fading up to 5 minutes
                             instantaneous recovery of the traffic;
                        •   deep fading for more than 5 minutes:
                            sign on of all the ATs (including traffic) in 10 minutes.




Technical Description                                                       EN/LZB 111 0542 P2B


                                         10-11                           MINI-LINK BAS




10.4          Power Supply
                      The MINI-LINK BAS is featured by the following power supply
                      parameters.

                      Input Voltage
                      -48 Vdc. Tolerance range:–38 V- –60 V.

                      AT Input Voltage
                      110/220 Vac. Tolerance range: 90-264 Vac
                      50/60 Hz. Tolerance range: 47-63 Hz

                      R-AAS Power Consumption
                      Fully equipped with six RNs, 350 W, indoor and ODU included

                      C-AAS (CE Shelf) Power Consumption
                      Fully equipped, 230 W.

                      AT Power Consumption
                      70 W including fully equipped indoor and ODU

                      CP
                      200 W

                      Power Efficiency
                      POU Max 32 W
                      PSU Max 50 W




EN/LZB 111 0542 P2B                                                   Technical Description


MINI-LINK BAS                              10-12




10.5            Antenna Data
                        For detailed ordering and information on electrical data of antennas
                        see the Product Catalogue. For further technical details please contact
                        your Ericsson representative.



10.5.1          Radio Node Antennas
                        The RN antenna for point-to-multipoint is a 90° sector antenna. The
                        half-power beamwidth in the azimuth direction is typically ±38° for
                        all the supported frequency bands.
                        The half-power beamwidth in elevation is typically 4.5°±0.4° for 26
                        GHz, 4.5°±0.3° for 28 GHz, and 4.4°±0.3° for 31 GHz.
                        In case of point-to-point connections, the directional AT antenna (see
                        10.5.2 for technical data) can be used on the RN as well.

                        RN Antenna Dimensions
                        296x266x118 mm, including radome.
                        Weight 3.8 kg. Mounting kit weight 2.3 kg.

                        RN Antenna Polarisation
                        Vertical and horizontal

                        RN Antenna Gain
                        Sector antenna 21±0.5 dBi for ETSI 26 GHz band, 21.7±0.5 dBi for
                        LMDS "A" 28 GHz band, and 21.2 dBi±0,5 dB for LMDS “B” 31
                        GHz.

                        RN Antenna EIRP
                        Typically 44 (41.5) dBm for ETSI 26 GHz band, 44.7 (42.2) dBm for
                        LMDS "A" 28 GHz band, and 44.2(41.7) dBm for LMDS “B” 31
                        GHz band. Guaranteed value within parentheses.




Technical Description                                                      EN/LZB 111 0542 P2B


                                         10-13                               MINI-LINK BAS




10.5.2        AT Antennas
                      0.24 m directional antenna with a 3.6 half-power beamwidth is
                      minimum 3.0° and maximum 4.1° for 26 GHz.
                      0.24 m directional antenna with a 3.3 half-power beamwidth is
                      minimum 2.9° and maximum 3.7° for 28 GHz.
                      0,24 directional antenna with a 3.0° is minimum 2.5° and maximum
                      3.4° for 31 GHz.
                      These antennas are used on the RN, in case of point-to-point
                      connection.
                      0.60 m antennas are available on request.

                      AT Antenna Dimensions
                      296x266x98 mm, including radome
                      Weight 2.5 kg
                      Mounting kit weights 2.9 kg.

                      AT Antenna Polarisation
                      Vertical and horizontal

                      AT Antenna Gain
                      •   ETSI 26 GHz, 33.8 ± 1 dBi for 0.24 m directional antenna
                      •   LMDS “A” 28 GHz, 34.6 ± 1 dBi for 0.24 m directional antenna
                      •   LMDS “B” 31 GHz, 34.6 ± 1 dBi for 0.24 m directional antenna

                      AT EIRP
                      •   ETSI 26 GHz, 56.8 (53.8) dBm for 0.24 m directional antenna
                      •   LMDS "A" 28 GHz, 57.6 (54.6) dBm for 0.24 m directional
                          antenna;
                      Note:     Guaranteed values are within parentheses.




EN/LZB 111 0542 P2B                                                       Technical Description


MINI-LINK BAS                              10-14




10.6            Environmental Requirements

10.6.1          Cabinets/Racks/Frames
                        BYB 501 can be used if compliance with ETS 300 119-2 is required.
                        Rear access C-AAS (CE Shelf) require cabinet that is lined up single-
                        in-line to allow the rear access. The cabinet may be metric or 19" or
                        23".



10.6.2          Power Distribution
                        If high ohmic distribution is available, no PDU is needed. If only low
                        ohmic distribution is available, the PDU is required in order to comply
                        with ETS 300 132-2.
                        If two wire distribution is available, 0V shall be connected to GND at
                        the input to the PDU or at the input of each subrack if the PDU is not
                        used.



10.6.3          EMC
                        Dummy front panels must be used to cover empty slots in the AAS's
                        as well as the FlexNU in order to comply with EMC requirements. All
                        front panels must be screwed to the subrack using proper torque in
                        order to comply with requirements on EMC and vibrations endurance.
                        Wrist strap (or other comparable means) shall be used when handling
                        ESD sensitive part.



10.6.4          Alarms
                        The following fan, power and external alarms are supported by HW:
                        •   Fan A-alarm, Fan B-alarm (A is more serious than B)
                        •   DC in alarm from POU
                        •   DC in alarm from redundant POU/ PSU
                        •   DC out alarm
                        •   DC out alarm from POU/PSU
                        •   External alarms




Technical Description                                                      EN/LZB 111 0542 P2B


                                         10-15                              MINI-LINK BAS




10.7          Characteristics
                      MINI-LINK BAS is based on the following general requirements:
                      •   ETS EN 301 213-1 for Europe
                      •   ETS EN 300 213-2 for Europe
                      •   FCC part 2 for US
                      •   FCC part101 for US



10.7.1        Central Office
                      The central office equipment is designed for compliance with the
                      following standards.

                      Safety
                      •   EN 60 950
                      •   UL 1950
                      •   CAN/CSA-C22.2 No. 950-95

                      Engineering Requirements for Racks, Cabinets and Subracks
                      •   ETS 300 119-2, BYB 311 and BYB 501
                      •   ETS 300 119-3, BYB 311
                      •   ETS 300 119-4, front access subracks
                      •   GR-63-CORE
                      •   GR-78-CORE

                      Electromagnetic Compatibility, EMC
                      •   ETS 300 385
                      •   GR-1089-CORE by FCC part 15, class B

                      Overvoltage (surge/lightning, power induction, power fault, EFT)
                      •   ETS 300 385,
                      •   ITU-T K.20
                      •   GR-1089-CORE, current limiting protector, heat coil, required

                      Environmental Conditions, Operational Environment
                      (climatic and mechanical endurance)
                      •   ETS 300 019-1-3 Class 3.1




EN/LZB 111 0542 P2B                                                      Technical Description


MINI-LINK BAS                              10-16



                            Full performance temperature:        +5°C - +40°C
                        •   Short period temperature:            -5°C - +50°C
                            No full performance
                            Period is less than 15 days/year or less than 96 hours.
                        •   GR-63-CORE, earthquake zone 4

                        Environmental Conditions, Transportation
                        (climatic and mechanical endurance)
                        •   ETS 300 019-1-2 Class 2.3
                        •   GR-63-CORE

                        Environmental Conditions, Storage (climatic endurance)
                        •   ETS 300 019-1-1 Class 1.1
                        •   GR-63-CORE

                        Power Supply Interface
                        •   ETS 300 132-2

                        Earthing and Bonding
                        •   ETS 300 253



10.7.2          AT
                        The Access Termination (AT) equipment is designed for compliance
                        with the following standards.

                        Safety
                        •   EN 60 950
                        •   UL 1950
                        •   CAN/CSA-C22.2 No. 950-95

                        Electromagnetic Compatibility, EMC
                        •   ETS 300 386-1, table 4
                        •   FCC part 15

                        Overvoltage (surge/lightning, power induction, power fault, EFT)
                        •   ETS 300 385
                        •   ITU-T K.21




Technical Description                                                      EN/LZB 111 0542 P2B


                                         10-17                                MINI-LINK BAS



                      Environmental Conditions, Operational Environment
                      (climatic and mechanical endurance)
                      •   ETS 300 019-1-3 Class 3.1 (with exception for solar radiation)
                      •   Full performance temperature:        +5°C - +40°C
                      •   Short period temperature:            -5°C - +50°C
                          No full performance
                          Period is less than 15 days/year or less than 96 hours.

                      Environmental Conditions, Transportation
                      (climatic and mechanical endurance)
                      •   ETS 300 019-1-2 Class 2.3
                      Environmental Conditions, Storage (climatic endurance)
                      •   ETS 300 019-1-1 Class 1.1



10.7.3        ODU
                      The ODU equipment is designed for compliance with the following
                      standards.

                      Safety
                      •   EN 60 950
                      •   EN 60 215
                      •   EN 60 529
                      •   UL 1950
                      •   CAN/CSA-C22.2 No. 950-95

                      Electromagnetic Compatibility, EMC
                      •   ETS 300 385
                      •   FCC Part 15

                      Overvoltage (surge/lightning, power induction, power fault, EFT,
                      etc)
                      •   ETS 300 385
                      •   ITU-T K.20
                      •   GR-1089-CORE, current limiting protector, heat coil, required




EN/LZB 111 0542 P2B                                                        Technical Description


MINI-LINK BAS                              10-18



                        Environmental Conditions, Operational Environment
                        (climatic and mechanical endurance)
                        •   ETS 300 019-2-4 class 4.1
                            Full performance, shade temperature:         -33°C - +60°C
                            Full performance temperature
                            plus solar radiation of 1120 W/m2:           -33°C - +45°C
                        •   TR-NW-000057

                        Environmental Conditions, Transportation
                        (Climatic and mechanical endurance)
                        •   ETS 300 019-2-2 Class 2.3
                        •   GR-63-CORE

                        Environmental Conditions, Storage
                        (climatic endurance)
                        •   ETS 300 019-1-1 Class 1.1
                        •   GR-63-CORE

                        Environmental Requirements, Wind Load
                        Installation gear is designed and tested for operational wind speed up
                        to 50 m/sec and survival conditions up to 70 m/sec. The load and
                        torque requirements, at operational wind velocity, are given in the
                        following table.


                               Antenna                   F (N)                  M (Nm)

                                0.24 m                    170                     40
                                0.60 m                    570                     180




Technical Description                                                      EN/LZB 111 0542 P2B


                                      10-19          MINI-LINK BAS




                            F



                                              M


                      Figure 10–2 Wind Load




EN/LZB 111 0542 P2B                               Technical Description


MINI-LINK BAS                              10-20




10.8            Miscellaneous Features
                        Mounting Devices
                        The standard antenna mounting kit for 0.24 m antennas consists of
                        two rigid, extruded aluminium profiles connected with a screw of
                        stainless steel.
                        The elevation can be adjusted in a ± 13° range. The azimuth can be
                        changed ± 65°.


                        AT Local Management Interface
                        RS-232 interface for ACT connection


                        AT Received Signal Strength
                        AT received signal strength is read directly from the ODU using a
                        standard voltmeter.


                        CP Hardware Platform
                        PU is a FORCE-TRI/50T, with Sparc Station similar functionality.
                        The CP platform is installed in a VME chassis, mounted in a 19” rack.
                        The operating system is Sun Solaris 2.6.


                        EM Hardware Platform
                        Minimum requirements are the following:
                        •   Sun Sparc Station Ultra 5
                        •   Sun Solaris 2.6 operating system
                        •   HP-OV




Technical Description                                                     EN/LZB 111 0542 P2B



Document Created: 2000-12-19 09:09:58
Document Modified: 2000-12-19 09:09:58