Test Report

FCC ID: O6RFIT1

Test Report

Download: PDF
FCCID_1111580

NVLAP Lab Code 200087-0




                     Application For
                   Grant of Certification
                                                      FOR

                                         Model: FIT1e
                                    P/N 010-00788-xx
                              Low Power Transmitter
                                    FCC ID: O6RFIT1
                                       IC: 3797A-FIT1
                                                       FOR

        DYNASTREAM INNOVATIONS, INC.
                                          228 River Avenue
                                  Cochrane, Alberta T4C 2C1
                                 Test Report Number 090419


Authorized Signatory:
                            Scot D. Rogers




Rogers Labs, Inc.           Dynastream Innovations, Inc.            FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                            IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054   PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210      Page 1 of 28
Revision 1                  File: TstRpt FIT1                       Date: May 11, 2009


NVLAP Lab Code 200087-0


                             ROGERS LABS, INC.
                             4405 West 259th Terrace
                             Louisburg, KS 66053
                             Phone / Fax (913) 837-3214


             Test Report For Application Of Certification
                                                        For

                 DYNASTREAM INNOVATIONS, INC.
                                              228 River Avenue
                                          Cochrane, Alberta T4C 2C1




                                              Model: FIT1e
                                          P/N 010-00788-xx
                                     Low Power Transmitter
                                     Frequency Range: 2,402-2,479 MHz
                                               FCC ID: O6RFIT1
                                                IC: 3797A-FIT1

Test Report Number: 090419
Test Date: April 19, 2009

Authorized Signatory:
                            Scot D. Rogers
                            Rogers Labs, Inc.
                            4405 West 259th Terrace
                            Louisburg, KS 66053
                            Telephone/Facsimile: (913) 837-3214

This report shall not be reproduced except in full, without the written approval of the laboratory.
This report must not be used by the client to claim product endorsement by NVLAP, NIST, or any
agency of the Federal Government.




Rogers Labs, Inc.           Dynastream Innovations, Inc.                   FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                   IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054          PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210             Page 2 of 28
Revision 1                  File: TstRpt FIT1                              Date: May 11, 2009


NVLAP Lab Code 200087-0

Table Of Contents

TABLE OF CONTENTS .................................................................................................... 3
FORWARD ....................................................................................................................... 5
APPLICABLE STANDARDS & TEST PROCEDURES .................................................... 5
OPINION / INTERPRETATION OF RESULTS ................................................................. 5
ENVIRONMENTAL CONDITIONS.................................................................................... 6
EQUIPMENT TESTED ...................................................................................................... 6
LIST OF TEST EQUIPMENT ............................................................................................ 6
2.1033(B) APPLICATION FOR CERTIFICATION ............................................................ 7
STATEMENT OF MODIFICATIONS AND DEVIATIONS ................................................. 8
EQUIPMENT AND CABLE CONFIGURATION ................................................................ 8
   Test Setup .................................................................................................................................................................. 8

EQUIPMENT FUNCTION AND TESTING PROCEDURES .............................................. 8
   Configuration options for the EUT ......................................................................................................................... 9

AC LINE CONDUCTED EMISSION TEST PROCEDURE ................................................ 9
   Radiated Emission Test Procedure ......................................................................................................................... 9

   Units of Measurements ............................................................................................................................................. 9

   Test Site Locations .................................................................................................................................................... 10

SUBPART C - INTENTIONAL RADIATORS .................................................................... 10
15.203 ANTENNA REQUIREMENTS ............................................................................... 10
15.205 RESTRICTED BANDS OF OPERATION.............................................................. 10
   Radiated Emissions in Restricted Bands Data per 15.205 .................................................................................... 11

   Summary of Results for Radiated Emissions in Restricted Bands 15.205........................................................... 11

15.209 RADIATED EMISSIONS LIMITS; GENERAL REQUIREMENTS ......................... 12
   General Radiated EMI per 15.209 .......................................................................................................................... 12
       Figure One Radiated Emissions in screen room .................................................................................................... 13
       Figure Two Radiated Emissions in screen room .................................................................................................... 13
       Figure Three Radiated Emissions in screen room .................................................................................................. 14
       Figure Four Radiated Emissions in screen room ................................................................................................... 14
       Figure Five Radiated Emissions in screen room .................................................................................................... 15
       Figure Six Radiated Emissions in screen room ...................................................................................................... 15
   General Radiated Emissions Data per 15.209 ........................................................................................................ 16

   Summary of Results for General Radiated Emissions per 15.209........................................................................ 16

Rogers Labs, Inc.                      Dynastream Innovations, Inc.                                                                    FCC ID: O6RFIT1
4405 West 259th Terrace                Model: FIT1e                                                                                    IC: 3797A-FIT1
Louisburg, KS 66053                    Test #:090419              SN: R5-054                                                           PN: 010-00788-xx
Phone/Fax: (913) 837-3214              Test to: FCC CFR47 15.249, RSS 210                                                              Page 3 of 28
Revision 1                             File: TstRpt FIT1                                                                               Date: May 11, 2009


NVLAP Lab Code 200087-0

15.249 OPERATION IN THE BAND 2,400-2,483.5 MHZ ................................................. 16
      Figure Seven output measured at temporary antenna terminal .............................................................................. 17
      Figure Eight output measured at temporary antenna terminal ............................................................................... 17
      Figure Nine output measured at temporary antenna terminal ................................................................................ 18
      Figure Ten output measured at temporary antenna terminal .................................................................................. 18
      Figure Eleven output measured at temporary antenna terminal ............................................................................. 19
      Figure Twelve Occupied Bandwidth ..................................................................................................................... 19
      Figure Thirteen Occupied Bandwidth .................................................................................................................... 20
      Figure Fourteen Occupied Bandwidth ................................................................................................................... 20
   Transmitter Radiated Emissions Data per 15.249 ................................................................................................. 21

   Summary of Results for Transmitter Radiated Emissions per 15.249 ................................................................ 21

ANNEX.............................................................................................................................. 22
   Annex A Measurement Uncertainty Calculations ................................................................................................. 23

   Annex B Test Equipment List For Rogers Labs, Inc. ........................................................................................... 25

   Annex C Rogers Qualifications ............................................................................................................................... 26

   Annex D FCC Test Site Registration Letter ........................................................................................................... 27

   Annex E Industry Canada Test Site Registration Letter ...................................................................................... 28




Rogers Labs, Inc.                  Dynastream Innovations, Inc.                                                           FCC ID: O6RFIT1
4405 West 259th Terrace            Model: FIT1e                                                                           IC: 3797A-FIT1
Louisburg, KS 66053                Test #:090419              SN: R5-054                                                  PN: 010-00788-xx
Phone/Fax: (913) 837-3214          Test to: FCC CFR47 15.249, RSS 210                                                     Page 4 of 28
Revision 1                         File: TstRpt FIT1                                                                      Date: May 11, 2009


NVLAP Lab Code 200087-0

Forward
The following information is submitted for consideration in obtaining Grant of Certification for
low power intentional radiator per CFR47 Paragraph 15.249, and Industry Canada RSS-210 Low
Power Transmitter, operation in the 2400 – 2483.5 MHz band.

         Name of Applicant:         Dynastream Innovations, Inc.
                                    228 River Avenue
                                    Cochrane, Alberta T4C 2C1
         Model: FIT1e, P/N 010-00788-xx

         FCC ID: O6RFIT1            Industry Canada ID: 3797A-FIT1

         Frequency Range: 2402-2479.0 MHz

         Operating Power: Less than 1 mW (as design specification, measured peak 91.9 dBμV/m
                          @ 3 meters), for operation in the 2402-2479 MHz, Occupied band
                          width 1,267 kHz

Applicable Standards & Test Procedures
In accordance with the Federal Communications Commission, Code of Federal Regulations
CFR47, dated October 1, 2008, Part 2, Subpart J, Paragraphs 2.907, 2.911, 2.913, 2.925, 2.926,
2.1031 through 2.1057, applicable parts of paragraph 15, Part 15C paragraph 15.249, and
Industry Canada RSS-210, the following information is submitted.

Test procedures used are the established Methods of Measurement of Radio-Noise Emissions as
described in the ANSI 63.4-2003 Document.


Opinion / Interpretation of Results
                                        Tests Performed                                   Results
 Antenna requirement per CFR47 15.203                                                   Complies
 Conducted Emissions as per CFR47 15.207                                                Complies
 Radiated Emissions as per CFR47 15.209                                                 Complies
 Emissions per CFR47 15.249                                                             Complies
 Emissions per RSS-210                                                                  Complies


Rogers Labs, Inc.           Dynastream Innovations, Inc.                   FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                   IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054          PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210             Page 5 of 28
Revision 1                  File: TstRpt FIT1                              Date: May 11, 2009


NVLAP Lab Code 200087-0

Environmental Conditions
                  Ambient Temperature                 23.1° C
                  Relative Humidity                   34%
                  Atmospheric Pressure                1022.4 mb

Equipment Tested
Equipment                                    Serial Number            FCC I.D.#
FIT1e (EUT)                                  R5-054                   O6RFIT1
FIT1e (Temp Antenna Port)                    R5-052                   (Sample #2)


List of Test Equipment
A Hewlett Packard 8591EM and or 8562A Spectrum Analyzer was used as the measuring device
for the emissions testing. The analyzer settings used are described in the following table. Refer
to the annex for a complete list of Test Equipment.

                              HP 8591EM Spectrum Analyzer Settings
                                         Conducted Emissions
              RBW                               AVG. BW              Detector Function
              9 kHz                               30 kHz             Peak/Quasi Peak
                                Radiated Emissions (30 – 1000 MHz)
              RBW                               AVG. BW              Detector Function
            120 kHz                              300 kHz             Peak/Quasi Peak
                               HP 8562A Spectrum Analyzer Settings
                                  Radiated Emissions (1 – 40 GHz)
              RBW                               AVG. BW              Detector Function
             1 MHz                                1 MHz               Peak/Average
                                    Antenna Conducted Emissions
              RBW                               AVG. BW              Detector Function
            120 kHz                              300 kHz                   Peak
Equipment         Manufacturer               Model                    Calibration Date         Due
LISN              Comp. Design               FCC-LISN-2-MOD.CD        10/08                    10/09
Antenna           ARA                        BCD-235-B                10/08                    10/09
Antenna           EMCO                       3147                     10/08                    10/09
Antenna           EMCO                       3143                     5/08                     5/09
Analyzer          HP                         8591EM                   5/08                     5/09
Analyzer          HP                         8562A                    5/08                     5/09

Rogers Labs, Inc.           Dynastream Innovations, Inc.                      FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                      IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054             PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210                Page 6 of 28
Revision 1                  File: TstRpt FIT1                                 Date: May 11, 2009


NVLAP Lab Code 200087-0


2.1033(b) Application for Certification

(1) Manufacturer:           Dynastream Innovations, Inc.
                            228 River Avenue
                            Cochrane, Alberta T4C 2C1

(2)      Identification: FCC I.D.: O6RFIT1                     IC: 3797A-FIT1

(3)      Copy of the installation and operating manual: Refer to exhibit for Draft Instruction
         Manual.

(4)      Description of Circuit Functions, Device Operation: The FIT1e, P/N 010-00788-xx is a
         low power transmitter offering wireless communications to compliant equipment. This
         device features low power transmitter operation in communications frequency band of
         2400-2483.5 MHz.

(5)      Block Diagram with Frequencies: Refer to exhibit for the Block Diagram

(6)      Report of measurements demonstrating compliance with the pertinent FCC/IC technical
         requires are provided in this report.

(7)      Photographs of equipment are provided in application exhibits.

(8)      Peripheral equipment or accessories for the equipment. No optional equipment is
         available for the EUT. Test samples were placed on support development (personality)
         boards attached to battery holder for testing. The available configuration options were
         investigated for this and other reports in compliance to required standards with worst-
         case data presented.

(9)      Transition Provisions of 15.37 are not being requested.

(10)     The equipment is not a scanning receiver.

(11)     The equipment is not a transmitter operating in the 59-64 GHz frequency range.




Rogers Labs, Inc.           Dynastream Innovations, Inc.                        FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                        IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054               PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210                  Page 7 of 28
Revision 1                  File: TstRpt FIT1                                   Date: May 11, 2009


NVLAP Lab Code 200087-0


Statement of Modifications and Deviations
No modifications to the EUT were required for the unit to demonstrate compliance with the FCC
CFR47 Parts 15C, or RSS-210 Emissions Standards. There were no deviations to the
specifications.


Equipment and Cable Configuration

Test Setup
The FIT1e, P/N 010-00788-xx is a low power transmitter allowing short-range communications
in the 2400-2483.5 MHz to compliant equipment. The unit was designed as a portable or
mounted device used in the fitness industry offering end user wireless data transfer. The
transmitter section allows for short-range communications to other compliant devices. The EUT
was arranged as typical user equipment configurations for testing purposes. The transmitter
offers no other interface connections than those in the configuration options shown below. The
EUT is powered from internal replaceable batteries only and offers no provision for alternate
power sources. As requested by the manufacturer and required by regulations, the unit was
tested for emissions compliance using the available configurations with the worst-case data
presented. Test results in this report relate only to the products described in this report.


Equipment Function and Testing Procedures
The EUT is a low power transmitter with transmitter operation capability in the 2402-2479 MHz
frequency band (CFR47 15.249 and RSS-210). The equipment offers communications to other
2402-2479 MHz compliant devices. Two samples were offered for testing. EUT (Sample #1)
was supplied for testing as a production design. Sample #2 was modified for testing purposes
only replacing the integral antenna with a 50 ohm antenna port. The EUT was placed on
development support PCB for testing purposes. The development PCB and battery support,
provided power and set frequency of operation during testing.




Rogers Labs, Inc.           Dynastream Innovations, Inc.                      FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                      IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054             PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210                Page 8 of 28
Revision 1                  File: TstRpt FIT1                                 Date: May 11, 2009


NVLAP Lab Code 200087-0


Configuration options for the EUT
  1. 010-00788-xx operating on development board and batteries

                                010-00788-XX

                                 Development
                                 PCB and AA
                                  Batteries



AC Line Conducted Emission Test Procedure
The equipment operates solely from direct current power and offers no provision to connect to
utility AC power. Therefore, no AC power line conducted emissions testing were performed for
this report.


Radiated Emission Test Procedure
Testing for the radiated emissions was performed as defined in sections 8.3 and 13.1 of ANSI
C63.4. The EUT was arranged in the test configurations as shown above and placed on a
rotating 1 x 1.5-meter wooden platform 0.8 meters above the ground plane at a distance of 3
meters from the FSM antenna. EMI energy was maximized by equipment placement, raising and
lowering the FSM antenna, changing the antenna polarization, and by rotating the turntable.
Each emission was maximized before final data was taken using a spectrum analyzer. Refer to
photographs in exhibits for EUT placement used during testing.


Units of Measurements
Conducted EMI:              Data is in dBµV; dB referenced to one microvolt.

Radiated EMI:               Data is in dBµV/m; dB/m referenced to one microvolt per meter.

Radiated Emissions Calculations:
         Note: The limit is expressed for a measurement in dBµV/m when the measurement is
         taken at a distance of 3 meters. Data taken for this report was taken at a distance of 3
         meters.

                   dBµV/m @ 3m = FSM(dBµV) + A.F.(dB/m) - Amp Gain(dB)
                   dBµV/m @ 3m = 15.8 + 33.0 – 20
                               = 28.8
Rogers Labs, Inc.           Dynastream Innovations, Inc.                       FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                       IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054              PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210                 Page 9 of 28
Revision 1                  File: TstRpt FIT1                                  Date: May 11, 2009


NVLAP Lab Code 200087-0

Test Site Locations
Conducted EMI               Rogers Labs, Inc. located at 4405 W. 259th Terrace, Louisburg, KS.

Radiated EMI                The radiated emissions tests were performed at Rogers Labs, Inc. 3 meters
                            Open Area Test Site (OATS) located at 4405 W. 259th Terrace,
                            Louisburg, KS.

Site Approval               Refer to Annex for FCC Site Registration Letter, Reference 90910,
                            Industry Canada Site Registration Reference 3041A-1


Subpart C - Intentional Radiators
As per CFR47 Part 15, Subpart C and RSS-210 the following information is submitted for
consideration in obtaining a grant of certification for unlicensed intentional radiators.


15.203 Antenna Requirements
The unit is produced with a permanently attached transmitter antenna etched on the PCB module.
No provisions for modification or alterations of the antenna configuration are available to the
end user. For testing purposes, a second test sample was modified to allow for antenna-
conducted emissions testing of transmitter for this and other compliance standards. The
requirements of 15.203 are met there are no deviations or exceptions to the specification.


15.205 Restricted Bands of Operation
Spurious emissions falling in the restricted frequency bands of operation were measured at the
OATS. The EUT utilizes frequency, determining circuitry, which generates harmonics falling in the
restricted bands. Emissions were investigated at the OATS, using appropriate antennas or pyramidal
horns, amplification stages, and a spectrum analyzer. Peak and average amplitudes of frequencies
above 1000 MHz were compared to the required limits with worst-case data presented below. Test
procedures of ANSI 63.4-2003 paragraphs 13.1 and 8.3.1.2 were used during testing. No other
significant emission was observed which fell into the restricted bands of operation. Computed
emission values take into account the received radiated field strength, receive antenna correction
factor, amplifier gain stage, and test system cable losses.

Rogers Labs, Inc.           Dynastream Innovations, Inc.                       FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                       IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054              PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210                 Page 10 of 28
Revision 1                  File: TstRpt FIT1                                  Date: May 11, 2009


NVLAP Lab Code 200087-0

Radiated Emissions in Restricted Bands Data per 15.205
   Emission           FSM           FSM           Ant.        Amp.   RFS Horz.    RFS Vert.         Limit
   Frequency          Horz.         Vert.        Factor       Gain     @ 3m         @ 3m            @ 3m
     (MHz)           (dBµV)        (dBµV)         (dB)        (dB)   (dBµV/m)     (dBµV/m)        (dBµV/m)

    2390.0            15.8          16.4         33.0          20      28.8         29.4              54.0

    2400.0            16.8          17.3         33.0          20      29.8         30.3              54.0

    2483.5            17.0          16.8         33.0          20      30.0         29.8              54.0

    4804.0            22.6          23.3         32.9          20      35.5         36.2              54.0

    4880.0            22.3          23.3         32.9          20      35.2         36.2              54.0

    4958.0            23.1          23.0         32.9          20      36.0         35.9              54.0

    7206.0            21.8          22.6         36.0          20      37.8         38.6              54.0

    7320.0            22.6          22.6         36.4          20      39.0         39.0              54.0

    7437.0            22.1          22.8         36.7          20      38.8         39.5              54.0

    12010.0           23.0          23.3         40.0          20      43.0         43.3              54.0

    12200.0           21.3          22.3         40.4          20      41.7         42.7              54.0

    12395.0           21.5          22.3         40.6          20      42.1         42.9              54.0

Other emissions found in the restricted bands were at least 20 dB below the limits.

Summary of Results for Radiated Emissions in Restricted Bands 15.205
The EUT demonstrated compliance with the radiated emissions requirements of FCC CFR47
Part 15.205 and RSS-210 restricted bands of operation. The EUT worst-case configuration
demonstrated minimum margin of 10.7 dB below the FCC and RSS-210 limits. Other emissions
were present with amplitudes at least 20 dB below the required limits.




Rogers Labs, Inc.           Dynastream Innovations, Inc.                         FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                         IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054                PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210                   Page 11 of 28
Revision 1                  File: TstRpt FIT1                                    Date: May 11, 2009


NVLAP Lab Code 200087-0


15.209 Radiated emissions limits; general requirements

General Radiated EMI per 15.209
The EUT was arranged on the support development board emulating worst-case equipment
configuration and operated through all of its various modes. Preliminary testing was performed
in a screen room with the EUT positioned 1 meter from the FSM. Radiated emissions
investigations were performed to identify the frequencies, which produced the highest emissions.
Plots were made of the radiated emission frequency spectrum from 30 MHz to 18,000 MHz for
preliminary transmitter testing. Refer to figures one through six the worst-case radiated emission
spectrum displayed on the spectrum analyzer taken in a screen room. The each radiated
emission measured was then re-maximized at the OATS site before final radiated emissions
measurements were performed. Final data was taken with the EUT located at the open field test
site at a distance of 3 meters between the EUT and the receiving antenna. Test procedures of
ANSI 63.4-2003 paragraphs 13.1 and 8.3.1.2 were used during radiated emissions testing. The
frequency spectrum from 30 MHz to 25,000 MHz was searched for radiated emissions. Peak
and average amplitudes of frequencies above 1000 MHz were compared to the required limits
with worst-case data presented below. Measured emission levels were maximized by EUT
placement on the table, changing cable location, rotating the turntable through 360 degrees,
varying the antenna height between 1 and 4 meters above the ground plane and changing antenna
polarization between horizontal and vertical. Antennas used were Broadband Biconical from 30
MHz to 200 MHz, Log Periodic from 200 MHz to 5 GHz, and/or Biconilog from 30 MHz to
1000 MHz, Double-Ridge horn and/or Pyramidal Horns from 5 GHz to 25 GHz, and
amplification stages.




Rogers Labs, Inc.           Dynastream Innovations, Inc.                   FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                   IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054          PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210             Page 12 of 28
Revision 1                  File: TstRpt FIT1                              Date: May 11, 2009


NVLAP Lab Code 200087-0




Figure One Radiated Emissions in screen room




Figure Two Radiated Emissions in screen room


Rogers Labs, Inc.           Dynastream Innovations, Inc.            FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                            IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054   PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210      Page 13 of 28
Revision 1                  File: TstRpt FIT1                       Date: May 11, 2009


NVLAP Lab Code 200087-0




Figure Three Radiated Emissions in screen room




Figure Four Radiated Emissions in screen room


Rogers Labs, Inc.           Dynastream Innovations, Inc.            FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                            IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054   PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210      Page 14 of 28
Revision 1                  File: TstRpt FIT1                       Date: May 11, 2009


NVLAP Lab Code 200087-0




Figure Five Radiated Emissions in screen room




Figure Six Radiated Emissions in screen room


Rogers Labs, Inc.           Dynastream Innovations, Inc.            FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                            IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054   PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210      Page 15 of 28
Revision 1                  File: TstRpt FIT1                       Date: May 11, 2009


NVLAP Lab Code 200087-0

General Radiated Emissions Data per 15.209
  Emission         FSM             FSM           Ant.      Amp.      RFS Horz.   RFS Vert.        Limit
 Freq. (MHz)       Horz.           Vert.        Factor     Gain        @ 3m        @ 3m           @ 3m
                  (dBµV)          (dBµV)         (dB)      (dB)      (dBµV/m)    (dBµV/m)       (dBµV/m)

   2400.0          16.8            17.3          33.0       20         29.8        30.3            54.0

   2483.5          17.0            16.8          33.0       20         30.0        29.8            54.0

Other emissions were present with amplitudes at least 20 dB below limits.


Summary of Results for General Radiated Emissions per 15.209
The EUT demonstrated compliance with the radiated emissions requirements of FCC Part 15C,
RSS-210 and other applicable standards for Intentional Radiators. The EUT worst-case
configuration demonstrated minimum margin of 23.7 dB below the limits. Other emissions were
present with amplitudes at least 20 dB below the Limits.


15.249 Operation in the Band 2,400-2,483.5 MHz
The power output was measured on an open area test site @ 3 meters. Test procedures of ANSI
63.4-2003 paragraphs 13.1 and 8.3.1.2 were used during testing. The EUT was placed on a
wooden turntable 0.8 meters above the ground plane and at a distance of 3 meters from the FSM
antenna. The peak and quasi-peak amplitude of frequencies below 1000 MHz were measured
using a spectrum analyzer. The peak and average amplitude of frequencies above 1000 MHZ
were measured using a spectrum analyzer. The amplitude of the emission was then recorded
from the analyzer display. Emissions radiated outside of the specified bands, except for
harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the
general radiated emission limits in 15.209, whichever is the lesser attenuation. Refer to figures
seven through fourteen showing the frequency and amplitude of emission displayed on the
spectrum analyzer measured at the temporary test antenna port (performed on sample #2). The
amplitudes of each radiated spurious emission were measured at the OATS at a distance of 3
meters from the FSM antenna. The amplitude of each radiated spurious emission was
maximized by varying the FSM antenna height, polarization, and by rotating the turntable. A
Biconilog Antenna was used for measuring emissions from 30 to 1000 MHz, a Log Periodic
Antenna for 200 to 5000 MHz, and Double-ridge horn and/or Pyramidal Horn Antennas from 4
GHz to 25 GHz. Emissions were measured in dBµV/m @ 3 meters.
Rogers Labs, Inc.           Dynastream Innovations, Inc.                          FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                          IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054                 PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210                    Page 16 of 28
Revision 1                  File: TstRpt FIT1                                     Date: May 11, 2009


NVLAP Lab Code 200087-0




Figure Seven output measured at temporary antenna terminal




Figure Eight output measured at temporary antenna terminal


Rogers Labs, Inc.           Dynastream Innovations, Inc.            FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                            IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054   PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210      Page 17 of 28
Revision 1                  File: TstRpt FIT1                       Date: May 11, 2009


NVLAP Lab Code 200087-0




Figure Nine output measured at temporary antenna terminal




Figure Ten output measured at temporary antenna terminal


Rogers Labs, Inc.           Dynastream Innovations, Inc.            FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                            IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054   PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210      Page 18 of 28
Revision 1                  File: TstRpt FIT1                       Date: May 11, 2009


NVLAP Lab Code 200087-0




Figure Eleven output measured at temporary antenna terminal




Figure Twelve Occupied Bandwidth


Rogers Labs, Inc.           Dynastream Innovations, Inc.            FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                            IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054   PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210      Page 19 of 28
Revision 1                  File: TstRpt FIT1                       Date: May 11, 2009


NVLAP Lab Code 200087-0




Figure Thirteen Occupied Bandwidth




Figure Fourteen Occupied Bandwidth


Rogers Labs, Inc.           Dynastream Innovations, Inc.            FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                            IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054   PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210      Page 20 of 28
Revision 1                  File: TstRpt FIT1                       Date: May 11, 2009


NVLAP Lab Code 200087-0

Transmitter Radiated Emissions Data per 15.249
                                                                      CFS @   CFS @    CFS @      CFS @
               FSM          FSM     FSM      FSM                       3m      3m       3m         3m
               Hor          Hor     Vert     Vert              Amp     Hor     Hor      Vert       Vert    Ave
 Frequency     Peak         Ave     Peak     Ave        AF     Gain    Peak    Ave      Peak       Ave     Limit

  2402.0       73.3         73.3    81.0     81.0      28.1     20    81.4    81.4      89.1       89.1    94.0

  4804.0       29.4         22.6    27.3     23.3      32.9     20    42.3    35.5      40.2       36.2    54.0

  7206.0       29.7         21.8    27.4     22.6      36.0     20    45.7    37.8      43.4       38.6    54.0

  9608.0       29.5         22.6    27.8     22.9      38.1     20    47.6    40.7      45.9       41.0    54.0

 12010.0       28.4         23.0    27.4     23.3      40.0     20    48.4    43.0      47.4       43.3    54.0

  2440.0       73.9         73.9    82.8     82.8      28.1     20    82.0    82.0      90.9       90.9    94.0

  4880.0       29.3         22.3    28.1     23.3      32.9     20    42.2    35.2      41.0       36.2    54.0

  7320.0       27.6         22.6    28.6     22.6      36.4     20    44.0    39.0      45.0       39.0    54.0

  9760.0       28.1         21.5    28.0     22.8      38.3     20    46.4    39.8      46.3       41.1    54.0

 12200.0       28.7         21.3    28.1     22.3      40.4     20    49.1    41.7      48.5       42.7    54.0

  2479.0       73.4         73.4    83.8     83.8      28.1     20    81.5    81.5      91.9       91.9    94.0

  4958.0       28.5         23.1    29.8     23.0      32.9     20    41.4    36.0      42.7       35.9    54.0

  7437.0       27.6         22.1    28.4     22.8      36.7     20    44.3    38.8      45.1       39.5    54.0

  9916.0       28.3         22.3    28.7     22.5      38.4     20    46.7    40.7      47.1       40.9    54.0

 12395.0       27.0         21.5    27.8     22.3      40.6     20    47.6    42.1      48.4       42.9    54.0

Note: Levels measured @ 3-meter OATS site.

Summary of Results for Transmitter Radiated Emissions per 15.249
The EUT demonstrated compliance with the radiated emissions requirements of FCC CFR47
Part 15.249, RSS-210 and other applicable standards for Intentional Radiators. The EUT worst-
case configuration demonstrated minimum peak amplitude emission margin of 2.1 dB below the
average limit. The EUT worst-case configuration demonstrated minimum radiated harmonic
emission margin of 10.7 dB below the limits. No other radiated emissions were found in the
restricted bands less than 20 dB below limits than those recorded in this report. Other emissions
were present with amplitudes at least 20 dB below the Limits.
Rogers Labs, Inc.            Dynastream Innovations, Inc.                             FCC ID: O6RFIT1
4405 West 259th Terrace      Model: FIT1e                                             IC: 3797A-FIT1
Louisburg, KS 66053          Test #:090419              SN: R5-054                    PN: 010-00788-xx
Phone/Fax: (913) 837-3214    Test to: FCC CFR47 15.249, RSS 210                       Page 21 of 28
Revision 1                   File: TstRpt FIT1                                        Date: May 11, 2009


NVLAP Lab Code 200087-0

Annex
•        Annex A Measurement Uncertainty Calculations

•        Annex B Test Equipment List.

•        Annex C Rogers Qualifications.

•        Annex D FCC Test Site Registration Letter

•        Annex E Industry Canada Test Site Registration Letter




Rogers Labs, Inc.           Dynastream Innovations, Inc.            FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                            IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054   PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210      Page 22 of 28
Revision 1                  File: TstRpt FIT1                       Date: May 11, 2009


NVLAP Lab Code 200087-0


Annex A Measurement Uncertainty Calculations
Radiated Emissions Measurement Uncertainty Calculation
Measurement of vertically polarized radiated field strength over the frequency range 30 MHz to
1 GHz on an open area test site at 3m and 10m includes following uncertainty:
                                                                 Probability                 Uncertainty
Contribution                                                     Distribution                     (dB)
Antenna factor calibration                                       normal (k = 2)                   ±0.58
Cable loss calibration                                           normal (k = 2)                   ±0.2
Receiver specification                                           rectangular                      ±1.0
Antenna directivity                                              rectangular                      ±0.1
Antenna factor variation with height                             rectangular                      ±2.0
Antenna factor frequency interpolation                           rectangular                      ±0.1
Measurement distance variation                                   rectangular                      ±0.2
Site Imperfections                                               rectangular                      ±1.5
Combined standard uncertainty uc(y) is


Uc(y) = ±
                       1.0 2 + 0.2 2 + 1.02 + 0.12 + 2.02 + 0.12 + 0.22 + 1.52
                        2       2                         3

Uc(y) = ± 1.6 dB
It is probable that uc(y) / s(qk)> 3, where s(qk) is estimated standard deviation from a sample of
n readings unless the repeatability of the EUT is particularly poor, and a coverage factor of k = 2
will ensure that the level of confidence will be approximately 95%, therefore:

                 1       n         _
s(qk) =       ------         (qk - q) 2
             (n-1)     ∑
                       k-1

U = 2 Uc(y) = 2 x ±1.6 dB = ± 3.2 dB

Notes:

1.1      Uncertainties for the antenna and cable were estimated, based on a normal probability distribution with k = 2.

1.2      The receiver uncertainty was obtained from the manufacturer's specification for which a rectangular distribution
         was assumed.

1.3      The antenna factor uncertainty does not take account of antenna directivity.

1.4      The antenna factor varies with height and since the height was not always the same in use as when the antenna
         was calibrated an additional uncertainty is added.




Rogers Labs, Inc.             Dynastream Innovations, Inc.                                FCC ID: O6RFIT1
4405 West 259th Terrace       Model: FIT1e                                                IC: 3797A-FIT1
Louisburg, KS 66053           Test #:090419              SN: R5-054                       PN: 010-00788-xx
Phone/Fax: (913) 837-3214     Test to: FCC CFR47 15.249, RSS 210                          Page 23 of 28
Revision 1                    File: TstRpt FIT1                                           Date: May 11, 2009


NVLAP Lab Code 200087-0

1.5      The uncertainty in the measurement distance is relatively small but has some effect on the received signal
         strength. The increase in measurement distance as the antenna height is increased is an inevitable consequence
         of the test method and is therefore not considered a contribution to uncertainty.
1.6      Site imperfections are difficult to quantify but may include the following contributions:
         -Unwanted reflections from adjacent objects.
         -Ground plane imperfections: reflection coefficient, flatness, and edge effects.
         -Losses or reflections from "transparent" cabins for the EUT or site coverings.
         -Earth currents in antenna cable (mainly effect biconical antennas).
The specified limits for the difference between measured site attenuation and the theoretical
value (± 4 dB) were not included in total since the measurement of site attenuation includes
uncertainty contributions already allowed for in this budget, such as antenna factor.


Conducted Measurements Uncertainty Calculation
Measurement of conducted emissions over the frequency range 9 kHz to 30 MHz includes
following uncertainty:
                                                      Probability                          Uncertainty
Contribution                                          Distribution                         (dB)
Receiver specification                                rectangular                          ±1.5
LISN coupling specification                           rectangular                          ±1.5
Cable and input attenuator calibration                normal (k=2)                         ±0.5
Combined standard uncertainty uc(y) is

Uc(y) = ±
                    0.5 2 + 1.52 + 1.52
                     2           3
Uc(y) = ± 1.2 dB

As with radiated field strength uncertainty, it is probable that uc(y) / s(qk)> 3 and a coverage
factor of k = 2 will suffice, therefore:
U = 2 Uc(y) = 2 x ±1.2 dB = ± 2.4 dB




Rogers Labs, Inc.           Dynastream Innovations, Inc.                                   FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                                   IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054                          PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210                             Page 24 of 28
Revision 1                  File: TstRpt FIT1                                              Date: May 11, 2009


NVLAP Lab Code 200087-0


Annex B Test Equipment List For Rogers Labs, Inc.
The test equipment used is maintained in calibration and good operating condition. Use of this
calibrated equipment ensures measurements are traceable to national standards.

List of Test Equipment                                              Calibration Date
Oscilloscope Scope: Tektronix 2230                                         2/09
Wattmeter: Bird 43 with Load Bird 8085                                     2/09
Power Supplies: Sorensen SRL 20-25, SRL 40-25, DCR 150, DCR 140            2/09
H/V Power Supply: Fluke Model: 408B (SN: 573)                              2/09
R.F. Generator: HP 606A                                                    2/09
R.F. Generator: HP 8614A                                                   2/09
R.F. Generator: HP 8640B                                                   2/09
Spectrum Analyzer: HP 8562A,                                               5/08
         Mixers: 11517A, 11970A, 11970K, 11970U, 11970V, 11970W
         HP Adapters: 11518, 11519, 11520
Spectrum Analyzer: HP 8591EM                                               5/08
Frequency Counter: Leader LDC825                                           2/09
Antenna: EMCO Biconilog Model: 3143                                        5/08
Antenna: EMCO Log Periodic Model: 3147                                     10/08
Antenna: Antenna Research Biconical Model: BCD 235                         10/08
Antenna: EMCO Dipole Set 3121C                                             2/09
Antenna: C.D. B-101                                                        2/09
Antenna: Solar 9229-1 & 9230-1                                             2/09
Antenna: EMCO 6509                                                         2/09
Audio Oscillator: H.P. 201CD                                               2/09
R.F. Power Amp 65W Model: 470-A-1010                                       2/09
R.F. Power Amp 50W M185- 10-501                                            2/09
R.F. PreAmp CPPA-102                                                       2/09
LISN 50 μHy/50 ohm/0.1 µf                                                  10/08
LISN Compliance Eng. 240/20                                                2/09
LISN Fischer Custom Communications FCC-LISN-50-16-2-08                     2/09
Peavey Power Amp Model: IPS 801                                            2/09
Power Amp A.R. Model: 10W 1010M7                                           2/09
Power Amp EIN Model: A301                                                  2/09
ELGAR Model: 1751                                                          2/09
ELGAR Model: TG 704A-3D                                                    2/09
ESD Test Set 2010i                                                         2/09
Fast Transient Burst Generator Model: EFT/B-101                            2/09
Current Probe: Singer CP-105                                               2/09
Current Probe: Solar 9108-1N                                               2/09
Field Intensity Meter: EFM-018                                             2/09
KEYTEK Ecat Surge Generator                                                2/09
Shielded Room 5 M x 3 M x 3.0 M




Rogers Labs, Inc.           Dynastream Innovations, Inc.                   FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                   IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054          PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210             Page 25 of 28
Revision 1                  File: TstRpt FIT1                              Date: May 11, 2009


NVLAP Lab Code 200087-0


Annex C Rogers Qualifications
Scot D. Rogers, Engineer

Rogers Labs, Inc.
Mr. Rogers has approximately 17 years experience in the field of electronics. Six years working
in the automated controls industry and 6 years working with the design, development and testing
of radio communications and electronic equipment.
Positions Held
         Systems Engineer:          A/C Controls Mfg. Co., Inc. 6 Years
         Electrical Engineer:       Rogers Consulting Labs, Inc. 5 Years
         Electrical Engineer:       Rogers Labs, Inc. Current
Educational Background
1)       Bachelor of Science Degree in Electrical Engineering from Kansas State University
2)       Bachelor of Science Degree in Business Administration Kansas State University
3)       Several Specialized Training courses and seminars pertaining to Microprocessors and
         Software programming.




Rogers Labs, Inc.           Dynastream Innovations, Inc.                   FCC ID: O6RFIT1
4405 West 259th Terrace     Model: FIT1e                                   IC: 3797A-FIT1
Louisburg, KS 66053         Test #:090419              SN: R5-054          PN: 010-00788-xx
Phone/Fax: (913) 837-3214   Test to: FCC CFR47 15.249, RSS 210             Page 26 of 28
Revision 1                  File: TstRpt FIT1                              Date: May 11, 2009


nviad


                      FEDERAL COMMUNICATIONS COMMISSION
                                                Laboratory Division
                                              7435 Oakland Mills Road
                                                Columbia, MD 21046

                                                     June 18, 2008


                                                                                          Registration Number: 90910
Rogers Labs, Inc.
4405 West 259th Terrace,
Louisburg, KS 66053

Attention:          Scot Rogers

 Re:                Measurement facility located at Louisburg
                    3 & 10 meter site
                    Date of Renewal: June 18, 2008


 Dear Sir or Madam:

 Your request for renewal of the registration of the subject measurement facility has been received. The information
 submitted has been placed in your file and the registration has been renewed. The name of your organization will
 remain on the list of facilities whose measurement data will be accepted in conjunction with applications for
 Certification under Parts 15 or 18 of the Commssion‘s Rules. Please note that the file must be updated for any
 changes made to the facility and the registration must be renewed at least every three years.

 Measurement facilities that have indicated that they are available to the public to perform measurement services on a
 fee basis may be found on the FCC website wwow.fcc.gov under E—Filing, OET Equipment Authorization Electronic
 Filing, Test Firms.


                                                                         Sincerely,


                                                                         Phyllis P
                                                                         Industry Analyst


nviad


    NeD sts: mare
    July 29th, 2008                                                           OUR FILE: 46405—3041
                                                                              Submussion No: 127059
    Rogers Labs Inc.
    4405 West 2591 Terrace
    Lousburg KY 66053
    USA

    Atiention. Scot D. Rogers

    Dear Sitr/Madame:
    The Bureau has received your application for the regastration / renewal of a 3/10m OATS. Be
    advised that the information received was satisfactory to Industry Canada. The following number(s)
    is now associated to the site(s) for which registration / renewal was sought (3040A—1). Please
    reference the appropniate site number in the body of test reports contaimng measurements performed
    on the site. In addition, please be informed that the Bureau is now utilizing a new site numbering
    scheme in order to simplify the electronic filing process. Our goal is to reduce the number of
    secondary codes associated to one particular company. The following changes have been made to
    your records.
              Your primary code is: 3041
              The company number associated to the site(s) located at the above address 1is: 3041A
              The table below is a summary of the changes made to the unique site registration
             number(s):
       New Site Number        Obsolete Site Number            Description of Site      Expiry Date
                                                                                       (Y¥YYY—MM—DD)


        304 1A¥—1               3041—1                          3 / 10m OATS             2010—07—29

    Furthermore, to obtain or renew a unmque site number, the applicant shall demonstrate that the site has
    been accredited to ANSI C€6S3.4—2003 or later. A scope of accreditation indicating the accreditation by
    a recognized accreditation body to ANSI C€63.4—2003 shall be accepted. Please indicate in a letter the
    previous assigned site number if applicable and the type of site (example: 3 meter OATS or 3 meter
    chamber). If the test facility is not accredited to ANSI C6S3.4—2003 or later, the test facility shall submit
    test data demonstrating full compliance with the ANSI standard. The Bureau will evaluate the filing to
    determine if recogmtion shall be granted.
    The frequency for re—validation of the test site and the information that is required to be filed or
    retained by the testing party shall comply with the requirements established by the accrediting
    organmization. However, in all cases, test site re—validation shall occur on an interval not to exceed two
    years. There is no fee or form associated with an OATS filing. OATS submissions are encouraged to
    be submitted electromcally to the Bureau using the following URL;
    If you have any questions, you may contact the Bureau by e—mail at certification.bureau@1ic.ge.ca
    Please reference our file and submission number above for all correspondence.
    Yours sincerely,
            seXe
    S. Proulx Wireless Laboratory
    Manager Certification and
    Engineering Bureau Industry Canada
    3701 Carling Ave., Buildng 94
    Ottawa, Ontario KZ2H 882
    Ccanada                                                                               Canada



Document Created: 2009-05-11 07:21:28
Document Modified: 2009-05-11 07:21:28

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC