EMC Test Report

FCC ID: NOIKBN873

Test Report

Download: PDF
FCCID_4411379

                                                               FCC Test Report

                        Report No.: FC190523E03

                             FCC ID: NOIKBN873

                        Test Model: N873

                  Received Date: May 27, 2019

                          Test Date: June 13, 2019

                      Issued Date: July 24, 2019


                          Applicant: NETRONIX, INC.

                            Address: No. 945, Boai St., Jubei City, Hsin-Chu,302,Taiwan, R.O.C.


                         Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                    Hsin Chu Laboratory
                     Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                  Taiwan R.O.C.
               Test Location (1): E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                  Taiwan R.O.C.
            Test Location (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin
                               Chu Hsien 307, Taiwan R.O.C.
         FCC Registration / 810758 / TW1085 for Test Location (1)
        Designation Number: 960022 / TW1058 for Test Location (2)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: FC190523E03                                              Page No. 1 / 25                                            Report Format Version: 6.1.2


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1     Certificate of Conformity ......................................................................................................................... 4
2     Summary of Test Results......................................................................................................................... 5
    2.1     Measurement Uncertainty ................................................................................................................... 5
    2.2     Modification Record ............................................................................................................................ 5
3     General Information ................................................................................................................................. 6
    3.1     Description of EUT .............................................................................................................................. 6
    3.2     Features of EUT .................................................................................................................................. 6
    3.3     Operating Modes of EUT and Determination of Worst Case Operating Mode ................................... 7
    3.4     Test Program Used and Operation Descriptions ................................................................................. 7
    3.5     Primary Clock Frequencies of Internal Source ................................................................................... 7
4     Configuration and Connections with EUT ............................................................................................. 8
    4.1     Connection Diagram of EUT and Peripheral Devices ......................................................................... 8
    4.2     Configuration of Peripheral Devices and Cable Connections ............................................................. 9
5     Conducted Emissions at Mains Ports .................................................................................................. 10
    5.1     Limits ................................................................................................................................................. 10
    5.2     Test Instruments ................................................................................................................................ 10
    5.3     Test Arrangement ............................................................................................................................... 11
    5.4     Supplementary Information ................................................................................................................ 11
    5.5     Test Results ....................................................................................................................................... 12
6     Radiated Emissions up to 1 GHz .......................................................................................................... 14
    6.1     Limits ................................................................................................................................................. 14
    6.2     Test Instruments ................................................................................................................................ 15
    6.3     Test Arrangement .............................................................................................................................. 16
    6.4     Supplementary Information ............................................................................................................... 16
    6.5     Test Results ....................................................................................................................................... 17
7     Radiated Emissions above 1 GHz......................................................................................................... 19
    7.1     Limits ................................................................................................................................................. 19
    7.2     Test Instruments ................................................................................................................................ 20
    7.3     Test Arrangement .............................................................................................................................. 21
    7.4     Supplementary Information ............................................................................................................... 21
    7.5     Test Results ....................................................................................................................................... 22
8     Pictures of Test Arrangements ............................................................................................................. 24
Appendix – Information of the Testing Laboratories ................................................................................. 25




Report No.: FC190523E03                                              Page No. 2 / 25                                               Report Format Version: 6.1.2


                                          Release Control Record


Issue No.             Description                                         Date Issued
FC190523E03           Original release.                                   July 24, 2019




Report No.: FC190523E03                      Page No. 3 / 25       Report Format Version: 6.1.2


1    Certificate of Conformity

              Product:    Electronic Display Device

                Brand:    Rakuten Kobo

            Test Model: N873
      Sample Status:      ENGINEERING SAMPLE
            Applicant:    NETRONIX, INC.

            Test Date:    June 13, 2019

           Standards:     47 CFR FCC Part 15, Subpart B, Class B
                          ICES-003:2016 Issue 6, updated Apr. 2019, Class B
                          ANSI C63.4:2014


The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                             ,   Date:       July 24, 2019
                               Wendy Wu / Specialist




     Approved by :                                              ,   Date:       July 24, 2019
                                 Ken Lu / Manager




Report No.: FC190523E03                       Page No. 4 / 25                        Report Format Version: 6.1.2


                                                                                                                      s




                                                                                                              coryl
                                                                                                               (%4
                                                                                                                ced




2      Summary of Test Results

47 CFR FCC Part 15, Subpart B / ICES—003:2016 Issue 6, updated Apr. 2019, Class B
ANSI C63.4:2014
     FGC       10ES—003                                                   Result/Remarks                  Verdict
    Clause      Clause
                              AC Power Line Conducted        |Minimum passing Class B margin is
    154997        100600      pnmissions                     —18.73 dB at 0.17344 MHz                       Pass
                 621          Radiated Emissions up to 1     Minimum passing Class B margin is              Pass
                   *          loys                           —2.18 dB at 270.85 MHz
    15.109                        —        —
                 6.2.2        Radiated Emissions above 1|    Minimum passing Class B margin is              Pass
                   e                                         —9.98 dB at 11469.87 MHz
Note: Determining compliance based on the results of the compliance measurement, not taking into account
      measurement instrumentation uncertainty.



2.1     Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT:

                           Measurement                                 Frequency           Expand(figzl;rzf)ertalnty
        Conducted Emissions at mains ports                       150kHz ~ 30MHz                    1.8 dB
             Radiated Emissions up to 1 GHz                       30MHz ~ 1GHz                     4.0 dB
                                                                      1GHz ~ 6GHz                  4.7 dB
             Radi
              adiated Emissi
                       Emissions above 1 GHz
                                          GH                      bGHz — i2GHz                     52 a6



2.2        Modification Record
There were no modifications required for compliance.




Report No.: FC190523E03                             Page No. 5 / 25                         Report Format Version: 6.1.2


3     General Information
3.1     Description of EUT

 Product                      Electronic Display Device
 Brand                        Rakuten Kobo
 Test Model                   N873
 Sample Status                ENGINEERING SAMPLE
 Operating Software           NA
 Power Supply Rating          3.7Vdc from battery or 5Vdc from USB interface
 Accessory Device             NA
 Data Cable Supplied          Refer to Note
Note:
1. The EUT may have black and white colors for marketing requirement.
2. The EUT must be supplied with a rechargeable battery as following table:
 Brand                    Model No.              Spec.
 EVE Energy CO., LTD         PR-158098N              Output: 3.7Vdc, 1200mAh, 4.44Wh
3. The antenna provided to the EUT, please refer to the following table:
                                              Antenna Net          Frequency     Antenna        Connector
         Brand                Model
                                               Gain (dBi)        Range (GHz)      Type            Type
   Walsin Technology                                                             Ceramic
                      RFECA3216060AAT                2            2.4~2.4835                       None
     Corporation                                                                 antenna
4. The EUT must be supplied with an eMMC as following table
 Brand                         Model                                  Size
 Sandisk                       SDINBDG4-8G                            8G Byte
5. The EUT must be supplied with a USB Cable and following different models could be chosen as following
   table:
   No        Brand           Model            Color                  Spec.               Difference
    1       Yih Fone        SH-0330           White             Shielded, 1.0m
                                                                                       Different color
    2       Yih Fone        SH-0152           Black             Shielded, 1.0m
6. The EUT incorporates a SISO function:
 MODULATION MODE                                     TX & RX CONFIGURATION
       802.11b                           1TX                                        1RX
       802.11g                           1TX                                        1RX
    802.11n (HT20)                       1TX                                        1RX
7. When USB port is charging the rechargeable battery, the EUT has WiFi function under charging mode.
   And the USB port is connected to Host unit on transmission mod, the EUT WiFi function will be disabled.



3.2     Features of EUT


The tests reported herein were performed according to the method specified by NETRONIX, INC., for detailed
feature description, please refer to the manufacturer's specifications or user's manual.




Report No.: FC190523E03                       Page No. 6 / 25                       Report Format Version: 6.1.2


3.3   Operating Modes of EUT and Determination of Worst Case Operating Mode


For radiated emission test, the EUT has been pre-tested under following test modes, and test mode A was the
worst case for final test.
                                                        Test Condition
 Pre-test Mode
                               Input                        Mode                    Arrangement
       A                 DC 5V With Host                    USB                Horizontal Placement
       B                      Battery                       WiFi                Horizontal Placement
       C                      Battery                       WiFi                 Vertical Placement
       D                      Battery                       WiFi                   Side Placement
Note: The test configurations are defined by the applicant requirement.


Test mode is presented in the report as below.
                                                       Test Condition
  Test Mode
                               Input                     Mode                      Arrangement
       1                  DC 5V With Host                 USB                  Horizontal Placement



3.4   Test Program Used and Operation Descriptions

1. Turn on the power of all equipment.
2. Support unit A (Laptop) runs a test program “EMC.bat” to enable EUT under “R/W mode” continually via
   one USB cable.
3. Support unit A (Laptop) runs” EMC test.exe” then sends "H" messages to itself.



3.5   Primary Clock Frequencies of Internal Source


The EUT is provided by NETRONIX, INC., for detailed internal source, please refer to the manufacturer's
specifications.




Report No.: FC190523E03                      Page No. 7 / 25                        Report Format Version: 6.1.2


4     Configuration and Connections with EUT
4.1    Connection Diagram of EUT and Peripheral Devices




                                                                        (2)
                                                                              (B)USB Mouse

                                      Micro      (1)
                                                            (A)Laptop
                            EUT       USB
                                                                        (3)
                                                                                (C)Printer




Report No.: FC190523E03                   Page No. 8 / 25                     Report Format Version: 6.1.2


4.2     Configuration of Peripheral Devices and Cable Connections


 ID          Product                  Brand                   Model No.           Serial No.         FCC ID           Remarks
 A.          Laptop                   DELL                      P70F              1KY07L2           FCC DoC       Provided by Lab
 B.        USB Mouse                  DELL                    MOC5UO             l1401MMP           FCC DoC       Provided by Lab
 C.          Printer                 EPSON                    LQ-300+II          G88Y074085         FCC DoC       Provided by Lab
Note:
1. All power cords of the above support units are non-shielded (1.8m).


 ID           Descriptions              Qty.        Length (m)     Shielding (Yes/No)     Cores (Qty.)            Remarks
 1.    USB to Micro USB Cable            1              1                  Yes                 0              Supplied by client
 2.           USB Cable                  1              1.8                Yes                 0              Provided by Lab
 3.           USB Cable                  1              1.8                Yes                 0              Provided by Lab
Note: The cores are originally attached to the cables




Report No.: FC190523E03                                  Page No. 9 / 25                                 Report Format Version: 6.1.2


5     Conducted Emissions at Mains Ports
5.1    Limits
                                            Class A (dBuV)                           Class B (dBuV)
       Frequency (MHz)
                                   Quasi-peak               Average         Quasi-peak            Average
         0.15 - 0.5                      79                   66               66 - 56             56 - 46
         0.50 - 5.0                      73                   60                 56                   46
         5.0 - 30.0                      73                   60                 60                   50
Notes: 1. The lower limit shall apply at the transition frequencies.
       2. The limit decreases linearly with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.

5.2    Test Instruments

DESCRIPTION &                                                         CALIBRATED            CALIBRATED
                             MODEL NO.           SERIAL NO.
MANUFACTURER                                                          DATE                  UNTIL
Test Receiver
                             ESCS 30             100375               May 15, 2019          May 14, 2020
R&S
Line-Impedance
Stabilization Network (for
                             NSLK-8127           8127-522             Sep. 03, 2018         Sep. 02, 2019
EUT)
SCHWARZBECK
Line-Impedance
Stabilization Network (for
                             NSLK-8127           8127-523             Oct. 19, 2018         Oct. 18, 2019
Peripheral )
SCHWARZBECK
RF Cable                     5D-FB               COACAB-002           Feb. 22, 2019         Feb. 21, 2020
10 dB PAD
                             STI02-2200-10       004                  Mar. 14, 2019         Mar. 13, 2020
EMEC
50 ohms Terminator           N/A                   EMC-03             Sep. 25, 2018         Sep. 24, 2019
50 ohms Terminator           N/A                   EMC-02             Sep. 12, 2018         Sep. 11, 2019
Software                     BVADT_Cond_
                                                  NA                  NA                    NA
BVADT                        V7.3.7.4

Note:
1. The calibration interval of the above test instruments are 12 months and the calibrations are traceable to
   NML/ROC and NIST/USA.
2. The test was performed in Conducted Room C
3. The VCCI Con C Registration No. is C-13611.
4. Tested Date: June 13, 2019




Report No.: FC190523E03                        Page No. 10 / 25                        Report Format Version: 6.1.2


5.3   Test Arrangement
a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being connected
   to the power mains through a line impedance stabilization network (LISN). Other support units were
   connected to the power mains through another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling
   impedance for the measuring instrument.
b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c. The test results of conducted emissions at mains ports are recorded of six worst margins for quasi-peak
   (mandatory) [and average (if necessary)] values against the limits at frequencies of interest unless the
   margin is 20 dB or greater.
Note: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP) and
      average detection (AV) at frequency 0.15MHz-30MHz.




For the actual test configuration, please refer to the related Item – Photographs of the Test Configuration.



5.4   Supplementary Information


There is not any deviation from the test standards for the test method.




Report No.: FC190523E03                        Page No. 11 / 25                         Report Format Version: 6.1.2


                                                                                                               ied
                                                                                                              Eusnn




5.5   Test Results


                                                            Detector Function        .
Frequency Range           150kHz ~ 3OMHz                    & Resolution        gg;?;e(i@g@ggljz
                                                            Bandwidth                            "
:gsz:e?)‘"e’              120Vac, 60Hz                      Conamane®""!        |25©, sexRH
Tested by                 Eagle Chen
Test Mode                 Mode 1


                                             Phase Of Power : Line (L)
        Frequency     |Correction|   Reading Value        Emission Level         Limit                   Margin
 No                      Factor         (dBuV)                (dBuV)            (dBuV)                    (dB)
           (MHz)          (dB)         QP.       AV.       Q.P.       AV.    Q.P.         AV.         Q.P.     AV.
  1      0.15391          10.01      35.21      20.62      45.22     30.63   65.79       55.79       —20.57   —25.16
  2      0.17344          10.01      36.05      15.82      46.06     25.83   64.79       54.79       —18.73   —28.96
  3      0.60703          10.06      21.48      8.83       31.54     18.89   56.00       46.00       —24.46   —27.11
  4      0.74766          10.07      21.18      8.89       31.25     18.96   56.00       46.00       —24.75   —27.04
  5      7.94531          10.39      26.04      17.79      36.43     28.18   60.00       50.00       —23.57   —21.82
  6      8.82031          10.42      23.84      16.67      34.26     27.09   60.00       50.00       —25.74   —22.91
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value




Report No.: FC190523E03                           Page No. 12 / 25                         Report Format Version: 6.1.2


                                                                                                                       ied
                                                                                                                  Eusnn




                                                            Detector Function           .
Frequency Range           150kHz ~ 3OMHz                    & Resolution        gg;?;e(i@g@ggljz
                                                            Bandwidth                               "
(S';/::en?) >
In       Power
                          120Vac, 60Hz                      Conamong" *
                                                            Environmental
                                                                                |25©, sexrH
                                                                                    s

Tested by                 Eagle Chen
Test Mode                 Mode 1


                                          Phase Of Power : Neutral (N)
          Frequency    |Correction|   Reading Value      Emission Level             Limit                   Margin
 No                       Factor         (dBuV)                 (dBuV)          (dBuV)                          (dB)
            (MHz)          (dB)        aP.      AV.        a.P.      AV.     a.P.            AV.         a.P.          AV.
     1     0.15000        10.01       35.64    20.50      45.65     30.51   66.00           56.00       —20.35     —25.49
     2     0.16953        10.01       34.99    17.17      45.00     27.18   64.98           54.98       —19.98     —27.80
     3     0.63047        10.06       21.01     8.90      31.07     18.96   56.00           46.00       —24.93     —27.04
     4     0.75938        10.06       18.75     8.76      28.81     18.82   56.00           46.00       —27.19     —27.18
     5    6.55859         10.29       2215     15.35      32.44     25.64   60.00           50.00       —27.56     —24.36
     6    13.69922        10.46       19.31    13.55      29.77     24.01   60.00           50.00       —30.23     —25.99
Remarks:
           1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
           2. The emission levels of other frequencies were very low against the limit.
           3. Margin value = Emission level — Limit value
           4. Correction factor = Insertion loss + Cable loss
           5. Emission Level = Correction Factor + Reading Value




Report No.: FC190523E03                           Page No. 13/ 25                              Report Format Version: 6.1.2


6     Radiated Emissions up to 1 GHz
6.1    Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
                             Radiated Emissions Limits at 10 meters (dBμV/m)
  Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                   CISPR 22, Class A CISPR 22, Class B
      (MHz)             Class A                 Class B
       30-88               39                      29.5
      88-216              43.5                     33.1                    40                      30
     216-230
                          46.4                     35.6
     230-960
                                                                           47                      37
    960-1000              49.5                     43.5

                              Radiated Emissions Limits at 3 meters (dBμV/m)
    Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                 CISPR 22, Class A      CISPR 22, Class B
       (MHz)            Class A                Class B
        30-88             49.5                    40
       88-216              54                    43.5                   50.5                     40.5
      216-230
                           56.9                     46
      230-960
                                                                       57.5                      47.5
     960-1000              60                       54

Notes: 1. The lower limit shall apply at the transition frequencies.
       2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
       3. QP detector shall be applied if not specified.




Report No.: FC190523E03                       Page No. 14 / 25                       Report Format Version: 6.1.2


6.2   Test Instruments
DESCRIPTION &                                                            CALIBRATED            CALIBRATED
                           MODEL NO.                 SERIAL NO.
MANUFACTURER                                                             DATE                  UNTIL
Test Receiver
                           N9038A                    MY50010125          Apr. 11, 2019         Apr. 10, 2020
Agilent
Test Receiver
                           ESR3                      102528              Feb. 22, 2019         Feb. 21, 2020
R&S
Pre-Amplifier              310N                      352925              Aug. 27, 2018         Aug. 26, 2019
Sonoma                     310N                      352926              Aug. 27, 2018         Aug. 26, 2019
Trilog Broadband           VULB 9168                 9168-359            Nov. 22, 2018         Nov. 21, 2019
Antenna
                           VULB 9168                 9168-358            Nov. 21, 2018         Nov. 20, 2019
SCHWARZBECK
Fixed attenuator           UNAT-5+                   CHF-001             Sep. 05, 2018         Sep. 04, 2019
Mini-Circuits              UNAT-5+                   CHF-002             Sep. 05, 2018         Sep. 04, 2019
                                                     CHFCAB-001-1
                                                     CHFCAB-001-3        Sep. 17, 2018         Sep. 16, 2019
                                                     CHFCAB-001-4
RF Cable                   8D-FB
                                                     CHFCAB-002-1
                                                     CHFCAB-002-3        Sep. 17, 2018         Sep. 16, 2019
                                                     CHFCAB-002-4
Software
                           ADT_Radiated_V8.7.08 NA                       NA                    NA
BVADT
Antenna Tower & Turn
Table                      NA                        NA                  NA                    NA
CT

Note:
1. The calibration interval of the above test instruments are 12 months and the calibrations are traceable to
   NML/ROC and NIST/USA.
2. The test was performed in Chamber F room
3. The VCCI Site Registration No. is R-13252.
4. Tested Date: June 13, 2019




Report No.: FC190523E03                        Page No. 15 / 25                          Report Format Version: 6.1.2


6.3   Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited test facility.
   The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 10 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the
   ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of
   the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
   the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
   hold mode when the test frequency is up to 1 GHz.

Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
      quasi-peak detection (QP) at frequency up to 1GHz.




For the actual test configuration, please refer to the related Item – Photographs of the Test Configuration.




6.4   Supplementary Information


 There is not any deviation from the test standards for the test method.




Report No.: FC190523E03                        Page No. 16 / 25                         Report Format Version: 6.1.2


                                                                                                                                 ezs
                                                                                                                               pmnsnm
                                                                                                                               veRitas



6.5   Test Results


                                                                    Detector Function &
Frequency Range             30MHz ~ 1GHz                            Resolution                       Quasi—Peak (QP), 120kHz
                                                                    Bandwidth

Input Power                 SVde                                    emiaunem®e                       25°C, 69%RH
Tested by                   Eagle Chen
Test Made                   Mode 1

                                Antenna Polarity & Test Distance : Horizontal at 10 m
        Prequeney           Emission       Limit       Margin     Antgnna       Table                               Raw     Correction
 No         (MHz)                Level     (dBuVv/m)         (dB)               Height             Angle          Value        Factor
                           (dBuV/m)                                               (m)             (Degree)        (dBuV)      (dB/m)
  1          30.11         23.90 QP         30.00            —6.10              4.00 H               42            38.37      —14.47
  2         243.79         30.19 QP         37.00            —6.81              4.00 H               14            43.38      —13.19
  3         270.85         34.82 QP         37.00            —2.18              3.93 H              236            47.03      ~12.21
  4         569.95         32.64 QP         37.00            ~4.36              2.00 H               14            37.09       ~4.45
  5         595.22         31.44 QP         37.00            —5.56              2.00 H               52            35.14       —3.70
  6         748.96         32.33 QP         37.00            ~4.67              1.00 H              217            32.94       —0.61
Remarks:
             1. Emission Level{dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
             2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                             — Pre—Amplifier Factor (dB)
             3. The other emission levels were very low against the limit.
             4. Margin value = Emission level — Limit value

                          Level
                      (dBuVim)
                          an—
                          70

                          60

                          50


                          40                 3                         173               s
                          30

                          20

                          10

                           0

                          10—         1           4             4          \        1         1        1      )
                               30—   100         300   400     510        600      700       800      $00    1000




Report No.: FC190523E03                                Page No. 17 / 25                                       Report Format Version: 6.1.2


                                                                                                            ezs
                                                                                                          pmnsnm




                                                            Detector Function &
Frequency Range           30MHz ~ 1GHz                      Resolution            Quasi—Peak (QP), 120kHz
                                                            Bandwidth

Input Power               SVde                              Coniaione®            25°C, 69%RH
Tested by                 Eagle Chen
Test Mode                 Mode 1

                                Antenna Polarity & Test Distance : Vertical at 10 m
        Ereguensy         Emission        Limit      Margin     Antgnna         Table       Raw        Correction
 No       (MHz)             Level      (dBuVv/m)       (dB)      Height        Angle       Value         Factor
                          (dBuV/m)                                  (m)       (Degree)    (dBuV)         (dB/m)
  1        39.75          25.11 QP       30.00        ~4.89      1.00 V          103       38.57         —13.46
  2       166.58          21.67 QP       30.00        —8.33      2.00 V          201       34.01         —12.34
  3       268.96          31.29 QP       37.00        —5.71      1.00 V          348       43.10         —11.81
  4       596.24          29.34 QP       37.00        —7.66      1.00 V          228       32.45          —3.11
  5       750.81          33.37 QP       37.00        —3.63      4.00 V          294       33.68          —0.31
  6       996.65          31.06 QP       37.00        —5.94      2.00 V           41       26.77          4.29
Remarks:
            1. Emission Level{dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                            — Pre—Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level — Limit value




                                                    Frequency (MHz)




Report No.: FC190523E03                          Page No. 18 / 25                        Report Format Version: 6.1.2


7     Radiated Emissions above 1 GHz
7.1    Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
                             Radiated Emissions Limits at 10 meters (dBμV/m)
    Frequencies    FCC 15B / ICES-003,      FCC 15B / ICES-003,
                                                                     CISPR 22, Class A       CISPR 22, Class B
       (MHz)            Class A                  Class B
    1000-3000              Avg: 49.5             Avg: 43.5              Not defined               Not defined
    Above 3000             Peak: 69.5            Peak: 63.5             Not defined               Not defined

                                 Radiated Emissions Limits at 3 meters (dBμV/m)
    Frequencies    FCC 15B / ICES-003,      FCC 15B / ICES-003,
                                                                     CISPR 22, Class A       CISPR 22, Class B
       (MHz)            Class A                  Class B
                                                                          Avg: 56                  Avg: 50
    1000-3000
                            Avg: 60               Avg: 54                 Peak: 76                 Peak: 70
                            Peak: 80              Peak: 74                Avg: 60                  Avg: 54
    Above 3000
                                                                          Peak: 80                 Peak: 74
Notes: 1. The lower limit shall apply at the transition frequencies.
       2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
       3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
          average detector, however, the peak field strength of any emission shall not exceed the maximum
          permitted average limits, specified above by more than 20dB under any condition of modulation.
Frequency Range (For unintentional radiators)
 Highest frequency generated or used in the device or
                                                               Upper frequency of measurement range (MHz)
      on which the device operates or tunes (MHz)
                          Below 1.705                                                30
                           1.705-108                                              1000
                           108-500                                                2000
                           500-1000                                               5000
                                                             5th harmonic of the highest frequency or 40GHz,
                          Above 1000
                                                                           whichever is lower




Report No.: FC190523E03                         Page No. 19 / 25                          Report Format Version: 6.1.2


7.2   Test Instruments
DESCRIPTION &                                                            CALIBRATED            CALIBRATED
                           MODEL NO.                  SERIAL NO.
MANUFACTURER                                                             DATE                  UNTIL
Test Receiver
                           N9038A                    MY50010125          Apr. 11, 2019         Apr. 10, 2020
Agilent
Pre-Amplifier
                           8449B                     3008A01975          Feb. 21, 2019         Feb. 20, 2020
Agilent
Horn Antenna
                           BBHA 9120D                D123                Nov. 25, 2018         Nov. 24, 2019
SCHWARZBECK
RF Coaxial Cable           EMC104-SM-SM-11000        170209              Mar. 05, 2019         Mar. 04, 2020
RF Coaxial Cable           EMC104-SM-SM-6000         170207              Mar. 05, 2019         Mar. 04, 2020
RF Coaxial Cable           EMC104-SM-SM-2500         170206              Mar. 05, 2019         Mar. 04, 2020
Software                   ADT_Radiated_
                                                     NA                  NA                    NA
BVADT                      V8.7.08
Antenna Tower & Turn
Table                      NA                        NA                  NA                    NA
CT
Fix tool for Boresight
                           BAF-01                    5                   NA                    NA
antenna tower

Note:
1. The calibration interval of the above test instruments are 12 months and the calibrations are traceable to
   NML/ROC and NIST/USA.
2. The test was performed in Chamber F room
3. Tested Date: June 13, 2019




Report No.: FC190523E03                        Page No. 20 / 25                          Report Format Version: 6.1.2


7.3   Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited chamber
   room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. The height of antenna can be varied from one meter to four meters, the height of adjustment depends on
   the EUT height and the antenna 3dB beamwidth both, to detect the maximum value of the field strength.
   Both horizontal and vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The spectrum analyzer system was set to peak and average detect function and specified bandwidth with
   maximum hold mode when the test frequency is above 1 GHz.

Note: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and video bandwidth is 3MHz for
      Peak detection (PK) at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
      analyzer is 1 MHz for Average detection (AV) at frequency above 1GHz.

  <Frequency Range 1GHz ~ 18GHz>


                                                     Ant. Tower
                                                                            1 - 4m
                                                                            Variable
         EUT&                            3m
        Support Units

                            Turn
                            Table         Absorber

          80cm



                                      Ground Plane

                                      Test Receiver




The test arrangement is in accordance with ANSI 63.4:2014. For the actual test configuration, please refer to
the related item – Photographs of the Test Configuration.




7.4   Supplementary Information
 There is not any deviation from the test standards for the test method.




Report No.: FC190523E03                       Page No. 21 / 25                         Report Format Version: 6.1.2


                                                                                                                                      ezs
                                                                                                                                    pmnsnm
                                                                                                                                    veRitas



7.5   Test Results


                                                                           Detectolr Function &           Peak (PK) /
Frequency Range                1GHz ~ 12.5GHz                              Sg;gwltgm                      Average (AV), 1MHz


Input Power                    SVde                                        Eg‘r’]';‘;mgma'                26°C, 65%RH
Tested by                      Eagle Chen
Test Made                      Mode 1

                                   Antenna Polarity & Test Distance : Horizontal at 3 m
                               Emission        l              ;     Antenna       Table                                  Raw     Correction
 No     Frt(a&t;ezr;cy           Level           ( déhn\q/'/tm)        M(erg;n       Height            Angle           Value        Factor
                               (dBuV/m)                                                (m)            (Degree)         (dBuV)      (dB/m)
  1      1170.00               39.69 PK            74.00               —34.31        1.00 H              21             43.51       —3.82
 2       1170.00               24.91 AV            54.00               —29.09        1.00 H             128             28.73       —3.82
 3       1997.05               40.96 PK            74.00               —33.04        1.00 H              96             41.16       —0.20
 4       1997.05               27.59 AV            54.00               —26.41        1.00 H             275             27.79       —0.20
 5       4245.30               44.35 PK            74.00               —29.65        1.00 H             360             36.63       7.72
 6       4245.30               30.77 AV            54.00               —23.23        1.00 H             286             23.05       7.72
 7       4791.43               48.12 PK            74.00               —25.88        1.00 H             202             34.61       13.51
 8       4791.43               35.03 AV            54.00               —18.97        1.00 H               0             21.52       13.51
 9       6657.18               48.40 PK            74.00               —25.60        1.00 H             246             34.13       14.27
 10      6657.18               35.08 AV            54.00               —18.92        1.00 H               0             20.81       14.27
 11      7983.60               52.42 PK            74.00               —21.58        1.00 H             282             34.73       17.69
 12      7983.60               38.37 AV            54.00               —15.63        1.00 H              116            20.68       17.69
Remarks:
            1. Emission Level{dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                            — Pre—Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level — Limit value

                           Level
                         (dBuVim)
                          90

                          80

                          70

                          60

                          50

                          40

                          30

                          20

                          10


                           0 1      i       i           1          1         1         1        1          1       1
                           1000 2000      4000        €000        8000     10000     12000    14000      16000   18000
                                                                   Frequency (MHz)




Report No.: FC190523E03                                       Page No. 22 / 25                                     Report Format Version: 6.1.2


                                                                                                                      ezs
                                                                                                                    pmnsnm
                                                                                                                    veRitas



                                                               Detector Function &        Peak (PK) /
Frequency Range            1GHz ~ 12.5GHz                      Resolution
                                                               Bandwidth                  Average (AV), 1MHz

                                                               Environmental                 s    o
Input Power                SVdc                                Conditions                 26°C, 65%RH

Tested by                  Eagle Chen
Test Mode                  Mode 1

                                Antenna Polarity & Test Distance : Vertical at 3 m
        Ereguensy         Emission        Limit      Margin    Antgnna         Table                  Raw        Correction
 No       (MHz)             Level      (dBuVv/m)      (dB)      Height         Angle                 Value         Factor
                          (dBuV/m)                                 (m)       (Degree)               (dBuV)         (dB/m)
  1      1768.83          48.45 PK       74.00       —25.55     1.00 V          360                  50.33          —1.88
  2      1768.83          24.52 AV       54.00       —29.48     1.00 V          193                  26.40          —1.88
  3     2989.85           46.21 PK       74.00       —27.79     1.00 V          202                  42.66          3.55
  4     2989.85           28.90 AV       54.00       —25.10     1.00 V          103                  25.35          3.55
  5     3329.85           45.13 PK       74.00       —28.87     1.00 V          302                  41.47          3.66
  6     3329.85           29.59 AV       54.00       —24.41     1.00 V          123                  25.93          3.66
  7     4813.10           47.09 PK       74.00       —26.91     1.00 V          147                  38.52          8.57
  8     4813.10           34.22 AV       54.00       —19.78     1.00 V           28                  25.65          8.57
  9     8680.17           52.15 PK       74.00       —21.85     1.00 V          113                  33.03          19.12
 10     8680.17           39.25 AV       54.00       —14.75     1.00 V           90                  20.13          19.12
 11     11469.87          56.61 PK       74.00       —17.39     1.00 V           53                  31.91         24.70
 12     11469.87          44.02 AV       54.00        —9.98     1.00 V          262                  19.32         24.70
Remarks:
            1. Emission Level{dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                            — Pre—Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level — Limit value




                          0 100         i     1         1        i         i       i       i
                          1000 2000   4000   €000     8000     10000     12000   14000   16000   18000
                                                       Frequency (MHz)




Report No.: FC190523E03                             Page No. 23 / 25                               Report Format Version: 6.1.2


8   Pictures of Test Arrangements


Please refer to the attached file (Test Setup Photo).




Report No.: FC190523E03                        Page No. 24 / 25   Report Format Version: 6.1.2


Appendix – Information of the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                    Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: FC190523E03                       Page No. 25 / 25                  Report Format Version: 6.1.2



Document Created: 2019-08-25 10:19:37
Document Modified: 2019-08-25 10:19:37

© 2024 FCC.report