Test Report

FCC ID: NMTWGR800X-01

Test Report

Download: PDF
FCCID_4098926

                                            FCC PART 15.231

                                               TEST REPORT
                                                               For

                                    IDT Technology Limited
                    9/F, Kaiser Estate, 41 Man Yue Street, Hung Hom, Kowloon, Hong Kong



                                     FCC ID: NMTWGR800X-01


            Report Type:                                    Product Type:
            Original Report                                 Integrated Wind Sensor


                    Report Number:           RXM181029052-00

                         Report Date:        2018-11-21

                                             Jerry Zhang
                        Reviewed By:         EMC Manager

                   Test Laboratory:          Bay Area Compliance Laboratories Corp. (Dongguan)
                                             No.69 Pulongcun, Puxinhu Industry Area,
                                             Tangxia, Dongguan, Guangdong, China
                                             Tel: +86-769-86858888
                                             Fax: +86-769-86858891
                                             www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk
“*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RXM181029052-00




                                                           TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................5
SUMMARY OF TEST RESULTS ...............................................................................................................................6
FCC §15.203 - ANTENNA REQUIREMENT.............................................................................................................7
  APPLICABLE STANDARD ..............................................................................................................................................7
FCC §15.205, §15.209, §15.231 (E) - RADIATED EMISSIONS ...............................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST PROCEDURE ......................................................................................................................................................10
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................10
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC §15.231(C) – 20 DB BANDWIDTH TESTING ................................................................................................14
  REQUIREMENT ...........................................................................................................................................................14
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................14
  TEST PROCEDURE ......................................................................................................................................................14
  TEST DATA ................................................................................................................................................................14
FCC §15.231(E) - DEACTIVATION TESTING ......................................................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................16
  TEST DATA ................................................................................................................................................................16




                                                                                                                                                            Page 2 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM181029052-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                       EUT Name:      Integrated Wind Sensor
                       EUT Model:     WGR800X
                           FCC ID:    NMTWGR800X-01
               Rated Input Voltage:   DC3V from battery
               External Dimension:    178mm(L)*76mm(W)*214mm(H)
                    Serial Number:    181029052
               EUT Received Date:     2018.10.30


Objective
This report is prepared on behalf of IDT Technology Limited in accordance with Part 2, Subpart J, Part 15,
Subparts A, and C of the Federal Communications Commission’s rules

The tests were performed in order to determine compliance with FCC Rules Part 15, Subpart C, and
section 15.203, 15.205, 15.209, and 15.231 rules.


Related Submittal(s)/Grant(s)
No related submittal(s)


Test Methodology
All measurements detailed in this Test Report were performed in accordance with ANSI C63.10-2013
“American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices”.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).


Measurement Uncertainty
               Parameter                                Measurement Uncertainty
       Occupied Channel Bandwidth                                ±5 %
                                        30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
       Unwanted Emissions, radiated
                                          6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
              Temperature                                         ±1℃
                Humidity                                          ±5%
      DC and low frequency voltages                              ±0.4%
               Duty Cycle                                          1%
       AC Power Lines Conducted                          3.12 dB (150 kHz to 30 MHz)
                Emission




                                                                                              Page 3 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM181029052-00

Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 897218,the FCC Designation No. : CN1220.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062D.




                                                                                             Page 4 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM181029052-00


SYSTEM TEST CONFIGURATION
Justification
The system was configured in testing mode which was provided by manufacturer.

The device operation frequency is 433.92 MHz.


Equipment Modifications
No modifications were made to the unit tested.


EUT Exercise Software
No software was used in test.


Block Diagram of Test Setup




                                                                                         Page 5 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM181029052-00

SUMMARY OF TEST RESULTS

                       FCC Rules                     Description of Test              Result

                         §15.203                     Antenna Requirement            Compliance

                       §15.207 (a)                   Conducted Emissions           Not applicable

              §15.205, §15.209, §15.231 (e)          Radiated Emissions             Compliance

                       §15.231 (c)                     20dB Bandwidth               Compliance

                       §15.231 (e)                    Transmission Time             Compliance


Not Applicable: the device was powered by battery.




                                                                                               Page 6 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RXM181029052-00

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.

Result: Compliant.

The EUT has 1 internal antenna, which was permanently attached, fulfill the requirement of this section.
Please refer to the EUT photos.




                                                                                                 Page 7 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RXM181029052-00

FCC §15.205, §15.209, §15.231 (e) - RADIATED EMISSIONS
Applicable Standard
FCC §15.205, §15.209, §15.231 (e)

     (e) Intentional radiators may operate at a periodic rate exceeding that specified in paragraph
(a) of this section and may be employed for any type of operation, including operation prohibited
in paragraph (a) of this section, provided the intentional radiator complies with the provisions of
paragraphs (b) through (d) of this section, except the field strength table in paragraph (b) of this
section is replaced by the following:

 Fundamental frequency            Field strength of fundamental         Field strength of spurious emissions
       (MHz)                            (microvolts/meter)                       (microvolts/meter)
40.66-40.70                 1,000                                 100
70-130                      500                                   50
                                        1
130-174                     500 to 1,500                          50 to 1501
174-260                     1,500                                 150
                                            1
260-470                     1,500 to 5,000                        150 to 5001
Above 470                   5,000                                 500
     1
         Linear interpolations.

      In addition, devices operated under the provisions of this paragraph shall be provided with a means
for automatically limiting operation so that the duration of each transmission shall not be greater than one
second and the silent period between transmissions shall be at least 30 times the duration of the
transmission but in no case less than 10 seconds.

EUT Setup
Below 1 GHz:




                                                                                                    Page 8 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                                    Report No.: RXM181029052-00

Above 1 GHz:




The radiated emission tests were performed in the 3 meters test site, using the setup accordance with the
ANSI C63.10-2013. The specification used was the FCC 15 § 15.209, 15.205 and 15.231.

EMI Test Receiver Setup
The system was investigated from 30 MHz to 5 GHz.

During the radiated emission test, the test receiver was set with the following configurations:

               Frequency Range              RBW            Video B/W        IF B/W          Measurement
              30 MHz – 1000 MHz            100 kHz          300 kHz        100 kHz               PK
                  1 GHz – 5 GHz            1 MHz            3 MHz                /               PK



Test Equipment List and Details

                                                                         Serial         Calibration   Calibration
    Manufacturer          Description              Model
                                                                        Number             Date        Due Date
        R&S            EMI Test Receiver           ESCI                 100224          2017-12-11    2018-12-11
        Farad           Test Software            EZ-EMC                 V1.1.4.2           N/A           N/A
    Sunol Sciences         Antenna                 JB3                 A060611-1        2017-11-10    2020-11-10
      Unknown           Coaxial Cable           C-NJNJ-50              C-0400-01        2018-09-05    2019-09-05
      Unknown           Coaxial Cable           C-NJNJ-50              C-0075-01        2018-09-05    2019-09-05
      Unknown           Coaxial Cable           C-NJNJ-50              C-1000-01        2018-09-05    2019-09-05
         HP               Amplifier               8447D               2727A05902        2018-09-05    2019-09-05
                          Spectrum
        Agilent                                   E4440A              SG43360054        2018-01-04    2019-01-04
                          Analyzer
     ETS-Lindgren       Horn Antenna              3115                000 527 35        2016-01-05    2019-01-04
      Unknown           Coaxial Cable           C-SJSJ-50             C-0800-01         2018-09-05    2019-09-05
                                             AFS42-00101800-
        MITEQ              Amplifier                                   2001271          2018-09-05    2019-09-05
                                                 25-S-42

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).

                                                                                                        Page 9 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM181029052-00

Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
According to §15.231, Intentional radiators operating under the provisions of this Section shall
demonstrate compliance with the limits on the field strength of emissions, based on the average value of
the measured emissions. As an alternative, compliance with the limits in the above table may be based on
the use of measurement instrumentation with a CISPR quasi-peak detector


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude


Test Results Summary
According to the data in the following table, the EUT complied with the CFR47 §15.205, §15.209,
§15.231 (e).


Test Data
    Environmental Conditions

        Temperature:           26.3~26.5 C
   Relative Humidity:              35 %
      ATM Pressure:              99.7kPa

 The testing was performed by Vern Shen ,Tyler Pan on 2018-11-15.

Test mode: Transmitting




                                                                                             Page 10 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RXM181029052-00

                                             Field Strength (Peak)

 Frequency      Receiver       Rx Antenna        Cable      Amplifier        Corrected           15.231 (e)
                Reading      Polar   Factor        loss       Gain           Amplitude        Limit      Margin
   (MHz)
                (dBμV)       (H/V)   (dB/m)       (dB)        (dB)           (dBμV/m)       (dBμV/m)      (dB)
                                     Operating Frequency: 433.92 MHz
    433.92        72.03        H      16.48       2.65        26.54             64.62          92.87        28.25
    433.92        65.49        V      16.48       2.65        26.54             58.08          92.87        34.79
    867.84        42.98        H      21.76       4.09        26.68             42.15          72.87        30.72
    867.84        40.17        V      21.76       4.09        26.68             39.34          72.87        33.53
   1301.76        52.76        H      24.53       1.57        35.95             42.91          74.00        31.09
   1301.76        52.87        V      24.53       1.57        35.95             43.02          74.00        30.98
   1735.68        45.61        H      26.19       1.65        36.06             37.39          74.00        36.61
   1735.68        46.09        V      26.19       1.65        36.06             37.87          74.00        36.13
   2169.60        47.41        H      27.64       1.74        36.18             40.61          74.00        33.39
   2169.60        47.04        V      27.64       1.74        36.18             40.24          74.00        33.76
   2603.52        48.07        H      28.67       1.88        36.38             42.24          74.00        31.76
   2603.52        49.42        V      28.67       1.88        36.38             43.59          74.00        30.41
   3037.44        47.51        H      30.19       2.18        37.04             42.84          74.00        31.16
   3037.44        46.98        V      30.19       2.18        37.04             42.31          74.00        31.69
   4339.20        45.24        H      32.33       2.85        37.00             43.42          74.00        30.58
   4339.20        46.27        V      32.33       2.85        37.00             44.45          74.00        29.55


Note:
According to C63.10-2013, clause 6.6.4.3, where limits are specified by regulations for both average and peak
detection, if the maximized peak measured value complies with the average limit(20dBc below the Peak limit), then
it is unnecessary to perform an average measurement.




                                                                                                       Page 11 of 17


 Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RXM181029052-00


 Horizontal:

Fundamental




                                                                      Page 12 of 17


 Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RXM181029052-00

 Vertical:

Fundamental




                                                                      Page 13 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RXM181029052-00

FCC §15.231(c) – 20 dB BANDWIDTH TESTING
Requirement
Per 15.231(c), The bandwidth of the emission shall be no wider than 0.25% of the center frequency for
devices operating above 70 MHz and below 900 MHz. Bandwidth is determined at the points 20 dB down
from the modulated carrier.


Test Equipment List and Details

                                                                       Serial       Calibration    Calibration
    Manufacturer             Description            Model
                                                                      Number           Date         Due Date
         R&S               EMI Test Receiver            ESCI          100224        2017-12-11     2018-12-11
        Sunol
                               Antenna                  JB3         A060611-1       2017-11-10     2020-11-10
       Sciences
       Unknown              Coaxial Cable         C-NJNJ-50          C-0400-01      2018-09-05     2019-09-05
       Unknown              Coaxial Cable         C-NJNJ-50          C-0075-01      2018-09-05     2019-09-05
       Unknown              Coaxial Cable         C-NJNJ-50          C-1000-01      2018-09-05     2019-09-05
          HP                  Amplifier             8447D           2727A05902      2018-09-05     2019-09-05

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
The waveform was received by the test antenna which was connected to the spectrum analyzer, plot the 20
dB bandwidth.


Test Data
 Environmental Conditions

        Temperature:                 26.5C
   Relative Humidity:                 35 %
      ATM Pressure:                 99.7 kPa

 The testing was performed by Vern Shen on 2018-11-15.

     Test Mode: Transmitting

    Please refer to following table and plot.

         Channel Frequency                 20 dB Bandwidth              Limit
                                                                                              Result
              (MHz )                            (kHz)                   (kHz)
                  433.92                        10.64                  1084.8                  Pass

     Note: Limit = 0.25% * Center Frequency = 0.25%*433.92MHz = 1084.8kHz


                                                                                                      Page 14 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)            Report No.: RXM181029052-00


                                           20 dB Bandwidth




                                                                              Page 15 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RXM181029052-00

FCC §15.231(e) - DEACTIVATION TESTING
Applicable Standard
Per 15.231(e)
In addition, devices operated under the provisions of this paragraph shall be provided with a means for
automatically limiting operation so that the duration of each transmission shall not be greater than one
second and the silent period between transmissions shall be at least 30 times the duration of the
transmission but in no case less than 10 seconds.


Test Equipment List and Details

                                                                       Serial        Calibration   Calibration
    Manufacturer           Description               Model
                                                                      Number            Date        Due Date
         R&S            EMI Test Receiver            ESCI             100224         2017-12-11    2018-12-11
        Sunol
                               Antenna                JB3            A060611-1       2017-11-10    2020-11-10
       Sciences
       Unknown            Coaxial Cable           C-NJNJ-50           C-0400-01      2018-09-05    2019-09-05
       Unknown            Coaxial Cable           C-NJNJ-50           C-0075-01      2018-09-05    2019-09-05
       Unknown            Coaxial Cable           C-NJNJ-50           C-1000-01      2018-09-05    2019-09-05
          HP                Amplifier               8447D            2727A05902      2018-09-05    2019-09-05

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
 Environmental Conditions

         Temperature:               26.5 C
   Relative Humidity:               35 %
      ATM Pressure:                99.7 kPa

 The testing was performed by Vern Shen on 2018-11-15.

     Test Mode: Transmitting

    Test Result: Compliance. Please refer to following plot.

                                     Deactivate
                     Deactivate                                     Silent Time
                                       Time           Silent Time
                       Time                                            Limit         Result
                                       Limit               (s)
                        (s)                                              (s)
                                        (s)
                        0.36              <1             13.2         >10.8           Pass




                                                                                                    Page 16 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RXM181029052-00


                                              Silent period




                                         Transmission duration




                                   *****END OF REPORT*****

                                                                                  Page 17 of 17



Document Created: 2018-12-04 17:31:47
Document Modified: 2018-12-04 17:31:47

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC