Test report RF

FCC ID: NJA-LR260

Test Report

Download: PDF
FCCID_4493157

                                                          SITRANS LR260
                                                          Model: 7ML5427
                                                         FCC ID: NJA-LR260
                                                             IC: 267P‐LR260

                                                                   Applicant:

                     Siemens Canada Ltd. - Siemens Milltronics Process Instruments
                                        1954 Technology Drive
                                           Peterborough, ON
                                            Canada K9J 6X7

                                                          In Accordance With

                                     Federal Communications Commission (FCC)
                                          Part 15, Subpart C, Section 15.256
                                                         And
                                       RS- 211 - Level Probing Radar Equipment

                                              UltraTech's File No.: SIEM-059F15C256

    This Test report is Issued under the Authority of
    Tri M. Luu
    Vice President of Engineering
    UltraTech Group of Labs

    Date: May 28, 2019

    Report Prepared by: Santhosh Fernandez                                   Tested by: Nimisha Desai




    Issued Date: May 28, 2019                                                Test Dates: April 2-5, 2019
     The results in this Test Report apply only to the sample(s) tested, and the sample tested is randomly selected.
     This report must not be used by the client to claim product endorsement by any agency of the US Government.
     This test report shall not be reproduced, except in full, without a written approval from UltraTech.



                                                              UltraTech
                                              3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4
                                                  Tel.: (905) 829-1570        Fax.: (905) 829-8050
                           Website: www.ultratech-labs.com, Email: vic@ultratech-labs.com, Email: tri@ultratech-labs.com




                                                                                                                     Korea
                                                                                                                    KCC-RRA
                                                                                                   SL2-IN-E-
                         91038         1309           46390-2049               AT-1945                                  CA2049
                                                                                                    1119R


FCC Part 15, Subpart C, Section 15.256 and RSS-211
SITRANS LR260, Model: 7ML5427                                                                                          FCC ID: NJA-LR260; IC: 267P-LR260




                                                                   TABLE OF CONTENTS

EXHIBIT 1.            INTRODUCTION .............................................................................................................................. 1
  1.1.      SCOPE ........................................................................................................................................................ 1
  1.2.      RELATED SUBMITTAL(S)/GRANT(S) ....................................................................................................... 1
  1.3.      NORMATIVE REFERENCES ..................................................................................................................... 1
EXHIBIT 2.            PERFORMANCE ASSESSMENT ................................................................................................... 2
  2.1.      CLIENT INFORMATION ............................................................................................................................. 2
  2.2.      EQUIPMENT UNDER TEST (EUT) INFORMATION .................................................................................. 2
  2.3.      EUT’S TECHNICAL SPECIFICATIONS ...................................................................................................... 3
  2.4.      ASSOCIATED ANTENNA DESCRIPTIONS ............................................................................................... 3
  2.5.      LIST OF EUT’S PORTS .............................................................................................................................. 3
  2.6.      ANCILLARY EQUIPMENT .......................................................................................................................... 3
  2.7.      GENERAL TEST SETUP ............................................................................................................................ 4
EXHIBIT 3.            EUT OPERATING CONDITIONS AND CONFIGURATIONS DURING TESTS ............................. 5
  3.1.      CLIMATE TEST CONDITIONS ................................................................................................................... 5
  3.2.      OPEPERATIONAL TEST CONDITIONS & ARRANGEMENT FOR TESTS ............................................... 5
EXHIBIT 4.            SUMMARY OF TEST RESULTS ..................................................................................................... 6
  4.1.      LOCATION OF TESTS ................................................................................................................................ 6
  4.2.      APPLICABILITY & SUMMARY OF EMC EMISSION TEST RESULTS ....................................................... 6
  4.3.      MODIFICATIONS INCORPORATED IN THE EUT FOR COMPLIANCE PURPOSES ............................... 6
EXHIBIT 5.            TEST DATA ..................................................................................................................................... 7
  5.1. RADIATED EMISSION FROM UNINTENTIONAL RADIATORS (DIGITAL CIRCUITRY) [47 CFR §15.209]
  ICES-003 ................................................................................................................................................................ 7
  5.2. FUNDAMENTAL EMISSION BANDWIDTH [47 CFR §15.256(F)] [RSS-211 §5.1] ..................................... 8
  5.3. RADIATED FUNDAMENTAL EMISSIONS [47 CFR 15.256(G)][RSS-211§ 5.2(B)]................................... 10
  5.4. RADIATED UNWANTED EMISSIONS [47 CFR 15.256(H)] [RSS-211§ 5.1 (D)] ....................................... 11
EXHIBIT 6.            TEST BLOCK DIAGRAMS AND EQUIPMENT LIST ................................................................... 12
  6.1.      FUNDAMENTAL EMISSIONS BANDWIDTH ........................................................................................................ 12
  6.2.      FUNDAMENTAL EMISSIONS LIMITS ................................................................................................................ 13
  6.3.      UNWANTED EMISSIONS ................................................................................................................................ 14
EXHIBIT 7.            MEASUREMENT UNCERTAINTY ................................................................................................ 15
  7.1.      LINE CONDUCTED EMISSION MEASUREMENT UNCERTAINTY ........................................................ 15
  7.2.      RADIATED EMISSION MEASUREMENT UNCERTAINTY ...................................................................... 15




ULTRATECH GROUP OF LABS                                                                                                                     File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                                                        May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                  Page 1 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260




EXHIBIT 1.           INTRODUCTION

1.1.         SCOPE
 Reference:                    FCC Part 15, Subpart C, Sec. 15.256 - Operation of level probing radars within the
                               bands 5.925-7.250 GHz, 24.05-29.00 GHz, and 75-85 GHz.
                               RS- 211 - Level Probing Radar Equipment
 Title:                        Code of Federal Regulations (CFR), Title 47 Telecommunication, Part 15, Subpart C -
                               Intentional Radiators
                               RS- 211 - Level Probing Radar Equipment
 Purpose of Test:              To gain permissive change FCC/ISED Equipment Authorization for FCC Part 15.256
                               and RS‐ 211 ‐ Level Probing Radar Equipment
 Test Procedures:              ANSI C63.4, ANSI C63.10 and KDB 890966 D01 Meas Level Probing Radars v01
 Environmental                 Commercial, industrial or business environment
 Classification:


1.2.         RELATED SUBMITTAL(S)/GRANT(S)
None.


1.3.         NORMATIVE REFERENCES
 Publication                    Year                      Title
 FCC 47 CFR 15                  2018                      Code of Federal Regulations (CFR), Title 47 –
                                                          Telecommunication, Part 15 Radio Frequency Devices
 ANSI C63.4                     2014                      American National Standard for Methods of Measurement of
                                                          Radio- Noise Emissions from Low-Voltage Electrical and
                                                          Electronic Equipment in the Range of 9 kHz to 40 GHz
 ANSI C63.10                    2013                      American National Standard for Testing Unlicensed Wireless
                                                          Devices
 KDB 890966 D01                 2014                      Measurement Procedure for Level Probing Radars
 Meas Level Probing
 Radars v01
 RSS-211                        2015                       Level Probing Radar Equipment




ULTRATECH GROUP OF LABS                                                                                                File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                  Page 2 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


EXHIBIT 2.           PERFORMANCE ASSESSMENT

2.1.         CLIENT INFORMATION
                                               Applicant
 Name:                               Siemens Canada Ltd. - Siemens Milltronics Process
                                     Instruments
 Address:                            1954 Technology Drive
                                     Peterborough, ON
                                     Canada K9J 6X7
 Contact Person:                     Thoai Bui
                                     Phone #: 705-740-7005
                                     Fax #: 705-741-0466
                                     Email Address: Thoai.bui@siemens,com


                                            Manufacturer
 Name:                               Siemens Canada Ltd. - Siemens Milltronics Process
                                     Instruments
 Address:                            1954 Technology Drive
                                     Peterborough, ON
                                     Canada K9J 6X7
 Contact Person:                     Thoai Bui
                                     Phone #: 705-740-7005
                                     Fax #: 705-741-0466
                                     Email Address: Thoai.bui@siemens,com


2.2.       EQUIPMENT UNDER TEST (EUT) INFORMATION
The following information (with the exception of the Date of Receipt) has been supplied by the applicant.

 Brand Name:                                           Siemens
 Product Name:                                         SITRANS LR260
 Model Name or Number:                                 7ML5427
 Serial Number:                                        Test sample
 Type of Equipment:                                    Level Probing Radar
 Input Power Supply Type:                              24V DC
 Primary User Functions of EUT:                        Level probing radars operate in open-air and inside an
                                                       enclosure containing the substance being measured




ULTRATECH GROUP OF LABS                                                                                                File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                  Page 3 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


2.3.         EUT’S TECHNICAL SPECIFICATIONS
 Transmitter
 Equipment Type:                                           Fixed
 Intended Operating Environment:                           Commercial, light industry & heavy industry
 Power Supply Requirement:                                 24 V DC
 Field Strength:                                           107.11 dBµV/m Peak at 3 m
 Operating Frequency Range:                                25.1 GHz
 RF Output Impedance:                                      50 Ω
 10 dB Bandwidth:                                          1490.98 MHz
 Modulation Type:                                          Pulse radar
 Oscillator Frequencies:                                   25 GHz
 Antenna Connector Type:                                   Integral


2.4.     ASSOCIATED ANTENNA DESCRIPTIONS
The EUT is equipped with the following antenna; the unit with highest gain antenna will be used for compliance
testing.
                                                 #1                                  #2                               #3
  Additional antenna list:              Without process                    With flanged horn              With aimer flanged horn
                                          connection
              Manufacture:                  SIEMENS                             SIEMENS                             SIEMENS
                                       3” Aluminum Horn                    3” Aluminum Horn                   3” Aluminum Horn
                        Type:
                                            Antenna                             Antenna                            Antenna
                                                                       7ML5427-0KRX0-XXXX                 7ML5427-0NRX0-XXXX
                                   7ML5427-0HRX0-XXXX
  Model (Configuration):                                               7ML5427-0LRX0-XXXX                 7ML5427-0PRX0-XXXX
                                   7ML5427-0JRX0-XXXX
                                                                       7ML5427-0MRX0-XXXX                 7ML5427-0QRX0-XXXX
        Frequency range:                24.05-29.00 GHz                    24.05-29.00 GHz                     24.05-29.00 GHz
                Impedance:              Waveguide input                    Waveguide input                     Waveguide input
                  Gain (dBi):                 22.9 dBi                           24.6 dBi                           23.5 dBi

2.5.         LIST OF EUT’S PORTS
    Port                                                    Number of                 Connector                      Cable Type
                    EUT’s Port Description
   Number                                                 Identical Ports               Type                  (Shielded/Non-shielded)
                  Loop power (Hart,
       1          Profibus PA and                                  1              Terminal block            Non-shielded, >3m
                  Foundation Fieldbus)


2.6.         ANCILLARY EQUIPMENT
None.



ULTRATECH GROUP OF LABS                                                                                                File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                   Page 4 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


2.7.         GENERAL TEST SETUP

2.7.1.       Fundamental Emissions, Unwanted Emissions and Emissions Bandwidth Test Setup




                                            24 Vdc
                                                                                                              Amplifier



                                                 DC Power
                                                  Supply




ULTRATECH GROUP OF LABS                                                                                                   File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                                May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                  Page 5 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


EXHIBIT 3.           EUT OPERATING CONDITIONS AND CONFIGURATIONS DURING TESTS

3.1.      CLIMATE TEST CONDITIONS
The climate conditions of the test environment are as follows:

 Temperature:                   21oC
 Humidity:                      51%
 Pressure:                      102 kPa
 Power input source:            24 VDC


3.2.         OPEPERATIONAL TEST CONDITIONS & ARRANGEMENT FOR TESTS
 Operating Modes:                               The EUT was configured for continuous transmission for the duration
                                                of testing.
 Special Test Software:                         N/A
 Special Hardware Used:                         N/A
 Transmitter Test Antenna:                      The EUT was tested with the antenna fitted in a manner typical of
                                                normal intended use as integral antenna equipment.

 Transmitter Test Signals:
 Frequency Band(s):                                                                25.1 GHz
 Test Frequency(ies):                                                              25.1 GHz
 Transmitter Wanted Output Test Signals:

      RF Power Output (measured maximum output power):                            107.11 dBµV/m Peak at 3 m

      Normal Test Modulation:                                                     Pulse radar

      Modulating signal source:                                                   Internal




ULTRATECH GROUP OF LABS                                                                                                File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                     Page 6 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


EXHIBIT 4.           SUMMARY OF TEST RESULTS

4.1.        LOCATION OF TESTS
All of the measurements described in this report were performed at Ultratech Group of Labs located in the city of
Oakville, Province of Ontario, Canada.

      AC Power Line Conducted Emissions were performed in UltraTech's shielded room, 24'(L) by 16'(W) by 8'(H).

      Radiated Emissions were performed at the Ultratech's 3-10 TDK Semi-Anechoic Chamber situated in the
       Town of Oakville, province of Ontario. This test site been calibrated in accordance with ANSI C63.4, and found to
       be in compliance with the requirements of Sec. 2.948 of the FCC Rules. The descriptions and site measurement data of
       the Oakville 3-10 TDK Semi-Anechoic Chamber has been filed with ANAB File No.: AT-1945.


4.2.          APPLICABILITY & SUMMARY OF EMC EMISSION TEST RESULTS
    FCC Regulations             Test Requirements                                                                   Compliance (Yes/No)
    &
    RSS-Gen/211
    15.203, 15.204 &            The transmitter shall utilize a dedicated or integrated                             Yes*
    15.256(b)                   transmit antenna and installation requirement of LPR
    RSS-211 §5.1
    15.209                      Emissions from Digital Circuitry                                                    Yes
    RSS-Gen
    15.256(f)                   Fundamental Emission Bandwidth                                                      Yes
    RSS-211 §5.1 (a)
    15.215(c) &                 Frequency Stability                                                                 N/A**
    15.256(f)(2)
    RSS-Gen
    15.256(g)                   Fundamental Emission                                                                Yes
    RSS-211 5.2 (b)
   15.256(h)               Unwanted Emissions                                       Yes
   RSS-211 5.1 (b)-
   (d)
* The EUT complies with the requirements; it employs integral antenna and is in compliance with the installation
  requirement.
** Not applicable for this C2PC


4.3.          MODIFICATIONS INCORPORATED IN THE EUT FOR COMPLIANCE PURPOSES
None.




ULTRATECH GROUP OF LABS                                                                                                     File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                                  May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                  Page 7 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


EXHIBIT 5.           TEST DATA

5.1.         RADIATED EMISSION FROM UNINTENTIONAL RADIATORS (DIGITAL CIRCUITRY) [47 CFR
             §15.209] [ICES-003]

5.1.1.       Limit(s)
The equipment shall meet the limits of the following table:

                                 §15.209(a) Radiated emission limits; general requirements

  Frequency (MHz)                  Field strength (microvolts/meter)                           Measurement distance (meters)
  0.009-0.490                      2400/F(kHz)                                                                                           300
  0.490-1.705                      24000/F(kHz)                                                                                            30
  1.705-30.0                       30                                                                                                      30
  30-88                            100**                                                                                                    3
  88-216                           150**                                                                                                    3
  216-960                          200**                                                                                                    3
  Above 960                        500                                                                                                      3

  **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this
  section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz.
  However, operation within these frequency bands is permItted under other sections of this part, e.g., §§15.231
  and 15.241.


5.1.2.       Method of Measurements
Refer to Ultratech Test Procedures ULTR-P001-2004 & ANSI C63.4 for method of measurements.
The spectrum shall be investigated from the lowest radio frequency signal generated or used in the device,
without going below the lowest frequency for which a radiated emission limit is specified, up to the frequency
specified in §15.33(a).
5.1.3.       Test Data

 Remark(s):

       All spurious emissions that are in excess of 20 dB below the specified limit shall be recorded.
                                 RF                   Detector                  Antenna
       Frequency                Level                  Used                      Plane                Limit at 3 m             Margin
         (MHz)                (dBµV/m)             (Peak/QP/Avg)                 (H/V)                 (dBµV/m)                 (dB)


                                                 No significant emissions were found




ULTRATECH GROUP OF LABS                                                                                                File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                  Page 8 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


5.2.         FUNDAMENTAL EMISSION BANDWIDTH [47 CFR §15.256(f)] [RSS-211 §5.1]

5.2.1.       Limit(s)
§15.256(f)The fundamental bandwidth of an LPR emission is defined as the width of the signal between two
points, one below and one above the center frequency, outside of which all emissions are attenuated by at least
10 dB relative to the maximum transmitter output power when measured in an equivalent resolution bandwidth.

§15.256(f)(1) The minimum fundamental emission bandwidth shall be 50 MHz for LPR operation under the
provisions of this section.

5.2.2.       Method of Measurements
890966 D01 Meas Level Probing Radars v01, Clause D.

5.2.3.       Test Data
   Test Frequency (GHz)                  Antenna Polarization                10 dB Bandwidth (MHz)                  Minimum Limit (MHz)
               25.1                                    V                                1490.98                                50
               25.1                                    H                                1418.83                                50


                                          Plot 5.2.3.1. 10 dB Bandwidth, Fc: 25.1 GHz- Vertical




ULTRATECH GROUP OF LABS                                                                                                File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                  Page 9 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260




                                         Plot 5.2.3.2. 10 dB Bandwidth, Fc: 25.1 GHz - Horizontal




ULTRATECH GROUP OF LABS                                                                                                File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                    Page 10 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


5.3.           RADIATED FUNDAMENTAL EMISSIONS [47 CFR 15.256(g)] [RSS-211§ 5.2(b)]

5.3.1.         Limits
15.256(g)(3) The EIRP limits for LPR operations in the bands authorized by this rule section are provided in Table
1. The emission limits in Table 1 are based on boresight measurements (i.e., measurements performed within the
main beam of an LPR antenna).

                                15.256(g)(3) - Table 1 LPR EIRP Emission Limits

 Frequency band of operation                     Average emission limit                                 Peak emission limit
           (GHz)                            (EIRP in dBm measured in 1 MHz)                      (EIRP in dBm measure in 50 MHz)
               5.925 - 7.250                                     -33                                                7
               24.05 - 29.00                                     -14                                                26
                  75 - 85                                        -3                                                 34


5.3.2.         Method of Measurements
FCC KDB Publication No. 890966 D01 Meas Level Probing Radars v01

5.3.3.         Test Data

5.3.3.1.       Radiated Fundamental Emissions, Average EIRP in 1 MHz
                                                                          1
                        Antenna            Average Emissions                  EIRP Average Emissions
     Frequency                                                                                                       Limit            Margin
                         Plane             Measured in 1 MHz                    Measured in 1 MHz
       (GHz)                                                                                                        (dBm)              (dB)
                         (H/V)                 (dBµV/m)                               (dBm)
        25.1                V                      60.47                              -34.79                         -14                 -20.79
        25.1                H                      62.79                              -32.47                         -14                 -18.47
 1
  EIRP is calculated by applying the radiated emission measurements equation, EIRP (dBm) = E (dBμV/m) – 104.8 + 20
 Log D, where D = 3



5.3.3.2.       Radiated Fundamental Emissions, Peak EIRP in 50 MHz
                                                                1                            2
                    Antenna        Peak Emissions                Peak Emissions               Peak EIRP Emissions
  Frequency                                                                                                                   Limit     Margin
                     Plane        Measured in 10 MHz           Calculated in 50 MHz           Calculated in 50 MHz
    (GHz)                                                                                                                    (dBm)       (dB)
                     (H/V)            (dBµV/m)                      (dBµV/m)                         (dBm)
       25.1             V                 90.52                         104.5                         9.24                    26         -16.76
       25.1             H                 93.13                        107.11                         11.85                   26         -14.15
 1
     Convert measurement in 10 MHz to 50 MHz by adding the correction factor 20*log(50/10) = 13.98 dB
 2
   EIRP is calculated by applying the radiated emission measurements equation, EIRP (dBm) = E (dBμV/m) – 104.8 + 20
 Log D, where D = 3




ULTRATECH GROUP OF LABS                                                                                                  File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                                  May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                   Page 11 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


5.4.         RADIATED UNWANTED EMISSIONS [47 CFR 15.256(h)] [RSS-211§ 5.1 (d)]

5.4.1.       Limits
Unwanted emissions from LPR devices shall not exceed the general emission limit in §15.209.

                                 §15.209(a) Radiated emission limits; general requirements

  Frequency (MHz)                  Field strength (microvolts/meter)                           Measurement distance (meters)
  0.009-0.490                      2400/F(kHz)                                                                                               300
  0.490-1.705                      24000/F(kHz)                                                                                               30
  1.705-30.0                       30                                                                                                         30
  30-88                            100**                                                                                                       3
  88-216                           150**                                                                                                       3
  216-960                          200**                                                                                                       3
  Above 960                        500                                                                                                         3

  **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this
  section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz.
  However, operation within these frequency bands is permItted under other sections of this part, e.g., §§15.231
  and 15.241.


5.4.2.       Method of Measurements
ANSI C63.10

5.4.3.       Test Data

5.4.3.1.     Field Strength of Emissions Outside the Permitted Band 30 MHz-40GHz at 3 m, 40 GHz-140 GHz
             @10 to 30 cm
                           Measured Field                                                              § 15.209 Field
       Frequency                                    Detector Used            Antenna Plane                                          Margin
                           Strength @ 3 m                                                             Strength Limits
         (MHz)                                      (Peak/QP/Avg)                (H/V)                                               (dB)
                              (dBµV/m)                                                                   (dBµV/m)
       30 - 140000                *                       Peak                      V/H                        *                      *
 * No unwanted emission detected that are in excess of 20 dB below the specified limit.




ULTRATECH GROUP OF LABS                                                                                                File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                                 May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                    Page 12 of 15
SITRANS LR260, Model: 7ML5427                                                                            FCC ID: NJA-LR260; IC: 267P-LR260


EXHIBIT 6.            TEST BLOCK DIAGRAMS AND EQUIPMENT LIST

6.1.         Fundamental Emissions Bandwidth




Test Instruments            Manufacturer               Model No.                Serial No.         Frequency Range                  Calibration
                                                                                                                                    Due Date
Spectrum Analyzer             Rohde & Schwarz               FSEK30                100077                 20 Hz – 40 GHz              30 Nov 2020

RF Amplifier                    Spacek Labs              SLKKa-30-6                6D26                    18 – 40 GHz                Cal on use

Horn Antenna                    ETS Lindgren                3160-09               118385                  18 – 26.5 GHz              27 Oct 2020

Power Supply                Tenma                      72-7295               490300297             1-40V, DC 5A                     ----
Multimeter                  Tenma                      72-6202               02080027              ---                              14 Dec 2019




ULTRATECH GROUP OF LABS                                                                                                  File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                                     May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                    Page 13 of 15
SITRANS LR260, Model: 7ML5427                                                                            FCC ID: NJA-LR260; IC: 267P-LR260


6.2.         Fundamental Emissions Limits




Test Instruments            Manufacturer               Model No.                Serial No.         Frequency Range                  Calibration
                                                                                                                                    Due Date
Spectrum Analyzer             Rohde & Schwarz               FSEK30                100077                 20 Hz – 40 GHz              30 Nov 2020

RF Amplifier                    Spacek Labs              SLKKa-30-6                6D26                    18 – 40 GHz                Cal on use

Horn Antenna                    ETS Lindgren                3160-09               118385                  18 – 26.5 GHz              27 Oct 2020

Power Supply                Tenma                      72-7295               490300297             1-40V, DC 5A                     ----
Multimeter                  Tenma                      72-6202               02080027              ---                              14 Dec 2019




ULTRATECH GROUP OF LABS                                                                                                  File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                                     May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                    Page 14 of 15
SITRANS LR260, Model: 7ML5427                                                                            FCC ID: NJA-LR260; IC: 267P-LR260


6.3.         Unwanted Emissions




                                  LR
                                  260


                         24 Vdc
                                                                                           Amplifier



                              DC Power
                               Supply

                                                                                          Spectrum
                                                                                          Analyzer




Test Instruments            Manufacturer               Model No.                Serial No.         Frequency Range                  Calibration
                                                                                                                                    Due Date
Spectrum Analyzer            Rohde & Schwarz                FSEK30                100077                 20 Hz – 40 GHz              30 Nov 2020

RF Amplifier                    Spacek Labs              SLKKa-30-6                6D26                    18 – 40 GHz                Cal on use

Horn Antenna                    ETS Lindgren                3160-09               118385                  18 – 26.5 GHz              27 Oct 2020

Horn Antenna                    ETS Lindgren                3160-10               102686                   26.5-40 GHz               27 Oct 2020

Horn Antenna                         OML                   M19HWD               U30625-1                   40 – 60 GHz              Note 1

Horn Antenna                         OML                   M12HWD                E30625-1                  60 – 90 GHz              Note 1

Horn Antenna                         OML                   M08HWD                F30625-1                 90 – 140 GHz              Note 1

Power Supply                Tenma                      72-7295               490300297             1-40V, DC 5A                     ----
Multimeter             Tenma                           72-6202               02080027              ---                              14 Dec 2019
Note 1: Dimensions Verified on use




ULTRATECH GROUP OF LABS                                                                                                  File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                                     May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.256 and RSS-211                                                                                  Page 15 of 15
SITRANS LR260, Model: 7ML5427                                                                          FCC ID: NJA-LR260; IC: 267P-LR260


EXHIBIT 7.           MEASUREMENT UNCERTAINTY
The measurement uncertainties stated were calculated in accordance with the requirements of CISPR 16-4-2 @
IEC:2003 and JCGM 100:2008 (GUM 1995) – Guide to the Expression of Uncertainty in Measurement.


7.1.         LINE CONDUCTED EMISSION MEASUREMENT UNCERTAINTY
         Line Conducted Emission Measurement Uncertainty
                                                                                                     Measured                 Limit
         (9 kHz – 30 MHz):
 uc      Combined standard uncertainty:
         uc(y) =  mui2(y)                                                                             + 1.44                + 1.8
                   I=1

 U       Expanded uncertainty U:
                                                                                                        + 2.89                + 3.6
         U = 2uc(y)


7.2.         RADIATED EMISSION MEASUREMENT UNCERTAINTY
         Radiated Emission Measurement Uncertainty @ 3m, Horizontal                                  Measured                 Limit
         (30-1000 MHz):                                                                                (dB)                   (dB)
 uc      Combined standard uncertainty:
         uc(y) =  mui2(y)                                                                             + 2.39                + 2.6
                   I=1


 U       Expanded uncertainty U:
                                                                                                        + 4.79                + 5.2
         U = 2uc(y)



         Radiated Emission Measurement Uncertainty @ 3m, Vertical                                    Measured                 Limit
         (30-1000 MHz):                                                                                (dB)                   (dB)
 uc      Combined standard uncertainty:                                                                 + 2.39                + 2.6
         uc(y) =  mui2(y)
                   I=1


 U       Expanded uncertainty U:                                                                        + 4.78                + 5.2
         U = 2uc(y)



        Radiated Emission Measurement Uncertainty @ 3 m, Horizontal &                                Measured                 Limit
        Vertical (1 – 18 GHz):                                                                         (dB)                   (dB)
 uc     Combined standard uncertainty:                                                                  + 1.87             Under
        uc(y) =  mui2(y)                                                                                              consideration
                   I=1

 U      Expanded uncertainty U:                                                                         + 3.75             Under
        U = 2uc(y)                                                                                                      consideration




ULTRATECH GROUP OF LABS                                                                                                File #: SIEM-059F15C256
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                                May 28, 2019
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)



Document Created: 2019-10-01 17:13:11
Document Modified: 2019-10-01 17:13:11

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC