Test Report

FCC ID: N6SLFADV

Test Report

Download: PDF
FCCID_1957662

                                               Certification Test Report

                                                            FCC ID: N6SLFADV
                                                             IC: 827B-LFADV

                                           FCC Rule Part: 15.209
                                 IC Radio Standards Specification: RSS-210

                                       ACS Report Number: 13-0073.W06.1A


                                                      Manufacturer: Gilbarco Inc.
                                                           Model: LFADV

                                                Test Begin Date: March 18, 2013
                                                 Test End Date: April 29, 2013

                                                Report Issue Date: May 2, 2013




                                       FOR THE SCOPE OF ACCREDITATION UNDER LAB Code 200612-0

This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of
                                                       the Federal Government.




                                                Reviewed by:
                                                                   Kirby Munroe
                                                         Director, Wireless Certifications
                                                                     ACS, Inc.

This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this report
                                                        are representative of the sample(s) submitted for evaluation.
                                                            This report contains 15 pages

                          5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


                                                         TABLE OF CONTENTS
1      GENERAL ............................................................................................................................................ 3
    1.1       PURPOSE.......................................................................................................................................... 3
    1.2       PRODUCT DESCRIPTION ................................................................................................................... 3
    1.3       TEST METHODOLOGY AND CONSIDERATIONS ................................................................................. 3
2      TEST FACILITIES .............................................................................................................................. 4
    2.1     LOCATION ....................................................................................................................................... 4
    2.2     LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS ................................................ 4
    2.3     RADIATED EMISSIONS TEST SITE DESCRIPTION .............................................................................. 5
       2.3.1    Semi-Anechoic Chamber Test Site .......................................................................................... 5
       2.3.2    Open Area Tests Site (OATS) ................................................................................................. 6
    2.4     CONDUCTED EMISSIONS TEST SITE DESCRIPTION ........................................................................... 7
3      APPLICABLE STANDARD REFERENCES.................................................................................... 7

4      LIST OF TEST EQUIPMENT ............................................................................................................ 8

5      SUPPORT EQUIPMENT .................................................................................................................... 9

6      EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ........................................................... 9

7      SUMMARY OF TESTS ......................................................................................................................10
    7.1     ANTENNA REQUIREMENT – FCC: SECTION 15.203 ........................................................................10
    7.2     POWER LINE CONDUCTED EMISSIONS – FCC: SECTION 15.207 IC: RSS-GEN 7.2.4.......................10
       7.2.1    Measurement Procedure ........................................................................................................10
       7.2.2    Measurement Results .............................................................................................................10
    7.3     RADIATED EMISSIONS – FCC CFR 47 PART 15.209 / RSS-210 SECTION 2.5..................................11
       7.3.1    Measurement Procedure ........................................................................................................11
       7.3.2    Distance Correction for Measurements Below 30 MHz – Part 15.31 ...................................12
       7.3.3    Measurement Results .............................................................................................................12
       7.3.4    Sample Calculation................................................................................................................13
    7.4     20DB / 99% BANDWIDTH – FCC: SECTION 15.215, IC: RSS-GEN 4.6.1 .........................................14
       7.4.1    Measurement Procedure ........................................................................................................14
       7.4.2    Measurement Results .............................................................................................................14
8      CONCLUSION ....................................................................................................................................15




                    5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: LFADV                           FCC ID: N6SLFADV                         IC: 827B-LFADV

1     GENERAL

1.1    Purpose

The purpose of this report is to demonstrate compliance with Part 15 Subpart C of the FCC’s
Code of Federal Regulations and Industry Canada’s Radio Standards Specification RSS-210 for
certification.

1.2    Product description

The model LFADV is a Radio Frequency Identification Device (RFID) which is designed for use in
conjunction with passive transponders (not requiring a battery), Texas Instruments Part # RI-
TRP-Series. The user carries the handheld transponder and the transmitter portion of the
LFECIM operates at 134.2kHz.

Technical Information:
Range of Operation: 134 kHz
Number of Channels: 1
Modulation Format: FSK
Antenna Type: Integral Loop
Operating Voltage: 24 VDC

Manufacturer Information:
Gilbarco Inc.
7300 West Friendly Ave.
Greensboro NC 27420

Test Sample Serial Number(s): 80296481

Test Sample Condition: The test samples were provided in good working order with no visible
defects.

1.3    Test Methodology and Considerations
The EUT was tested in an orientation of typical installation using a fixture which represents the
final configuration. A tag was presented to the EUT (i.e. tag reader) to provide continuous
transmit functionality for test purposes. An external test board and power supply was included in
the test setup to provide power to the EUT.

In order to comply with 15.209 regulations, the LFADV needed a ferrite placed on the antenna
and power/data cables. The part number of the ferrite used on the antenna cable was Steward
Ferrite 28A2025-0A0. The part number of the ferrite used on the power/data cable was Steward
Ferrite 28A2029-0A0. See the external photo exhibit included in this filing for photographs of this
modification.




ACS Report: 13-0073.W06.1A                Advanced Compliance Solutions                   Page 3


Model: LFADV                          FCC ID: N6SLFADV                        IC: 827B-LFADV

2     TEST FACILITIES

2.1     Location

The radiated and conducted emissions test sites are located at the following address:

      Advanced Compliance Solutions
      5015 B.U. Bowman Drive
      Buford, GA 30518
      Phone: (770) 831-8048
      Fax: (770) 831-8598

2.2     Laboratory Accreditations/Recognitions/Certifications

ACS is accredited to ISO/IEC 17025 by the National Institute of Standards and Technology under
their National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 200612-0. Unless
otherwise specified, all tests methods described within this report are covered under the ISO/IEC
17025 scope of accreditation.

The Semi-Anechoic Chamber Test Site, Open Area Test Site (OATS) and Conducted Emissions
Site have been fully described, submitted to, and accepted by the FCC, Industry Canada and the
Japanese Voluntary Control Council for Interference by information technology equipment.

FCC Registration Number: 511277
Industry Canada Lab Code: IC 4175A-1
VCCI Member Number: 1831
•       VCCI OATS Registration Number R-1526
•       VCCI Conducted Emissions Site Registration Number: C-1608




ACS Report: 13-0073.W06.1A               Advanced Compliance Solutions                  Page 4


Model: LFADV                           FCC ID: N6SLFADV                          IC: 827B-LFADV

2.3     Radiated Emissions Test Site Description

2.3.1    Semi-Anechoic Chamber Test Site

The Semi-Anechoic Chamber Test Site consists of a 20’ x 30’ x 18’ shielded enclosure. The
chamber is lined with Toyo Ferrite Grid Absorber, model number FFG-1000. The ferrite tile grid is
101 x 101 x 19mm thick and weighs approximately 550 grams. These tiles are mounted on steel
panels and installed directly on the inner walls of the chamber.

The turntable is 150cm in diameter and is located 160cm from the back wall of the chamber. The
chamber is grounded via 1 - 8’ copper ground rod, installed at the center of the back wall, it is
bound to the ground plane using 3/4" stainless steel braided cable.

The turntable is all steel, flush mounted table installed in an all steel frame. The table is remotely
operated from inside the control room located 25’ from the range. The turntable is electrically
bonded to the surrounding ground plane via steel fingers installed on the edge of the turn table.
The steel fingers make constant contact with the ground plane during operation.

Behind the turntable is a 3’ x 6’ x 4’ deep shielded pit used for support equipment if necessary.
The pit is equipped with 1 - 4” PVC chases from the turntable to the pit that allow for cabling to
the EUT if necessary. The underside of the turntable can be accessed from the pit so cables can
be supplied to the EUT from the pit.

A diagram of the Semi-Anechoic Chamber Test Site is shown in Figure 2.3-1 below:




                                             3 Meters


                                                                         5 Feet
                                                                        Diameter




                                                                                    20 Feet


                                               30 Feet
                        Figure 2.3-1: Semi-Anechoic Chamber Test Site




ACS Report: 13-0073.W06.1A                 Advanced Compliance Solutions                   Page 5


Model: LFADV                          FCC ID: N6SLFADV                          IC: 827B-LFADV

2.3.2   Open Area Tests Site (OATS)

The open area test site consists of a 40’ x 66’ concrete pad covered with a perforated electro-
plated galvanized sheet metal. The perforations in the sheet metal are 1/8” holes that are
staggered every 3/16”. The individual sheets are placed to overlap each other by 1/4” and are
riveted together to provide a continuous seam. Rivets are spaced every 3” in a 3 x 20 meter
perimeter around the antenna mast and EUT area. Rivets in the remaining area are spaced as
necessary to properly secure the ground plane and maintain the electrical continuity.

The entire ground plane extends 12’ beyond the turntable edge and 16’ beyond the antenna mast
when set to a 10 meter measurement distance. The ground plane is grounded via 4 - 8’ copper
ground rods, each installed at a corner of the ground plane and bound to the ground plane using
3/4" stainless steel braided cable.

The turntable is an all aluminum 10’ flush mounted table installed in an all aluminum frame. The
table is remotely operated from inside the control room located 40’ from the range. The turntable
is electrically bonded to the surrounding ground plane via steel fingers installed on the edge of
the turn table. The steel fingers make constant contact with the ground plane during operation.

Adjacent to the turntable is a 7’ x 7’ square and 4’ deep concrete pit used for support equipment if
necessary. The pit is equipped with 5 - 4” PVC chases from the pit to the control room that allow
for cabling to the EUT if necessary. The underside of the turntable can be accessed from the pit
so cables can be supplied to the EUT from the pit. The pit is covered with 2 sheets of 1/4"
diamond style re-enforced steel sheets. The sheets are painted to match the perforated steel
ground plane; however the underside edges have been masked off to maintain the electrical
continuity of the ground plane. All reflecting objects are located outside of the ellipse defined in
ANSI C63.4.

A diagram of the Open Area Test Site is shown in Figure 2.3-2 below:



                                             10

                                                        3 Meters



                                                                                  40




                                                                      7x7x4
                                                                       Pit

                                           66 Feet

                               Figure 2.3-2: Open Area Test Site




ACS Report: 13-0073.W06.1A                Advanced Compliance Solutions                  Page 6


Model: LFADV                             FCC ID: N6SLFADV                          IC: 827B-LFADV

2.4       Conducted Emissions Test Site Description

The AC mains conducted EMI site is located in the main EMC lab. It consists of an 8’ x 8’ solid
aluminum horizontal ground reference plane (GRP) bonded every 3” to an 8’ X 8’ vertical ground
plane.

The site is of sufficient size to test table top and floor standing equipment in accordance with
section 6.1.4 of ANSI C63.4.

A diagram of the room is shown below in figure 4.1.3-1:



                   Vertical Ground Plane (8’ x 8’)




                                                      Non-Conductive EUT Table
                                                          (1m x 1.5m x .8m)


              .4 Meters




                 .8 Meters


                                                            Horizontal Ground Plane (8’ x 8’)

               LISN
                             Figure 2.4-1: AC Mains Conducted EMI Site

3     APPLICABLE STANDARD REFERENCES

The following standards were used:

          ANSI C63.4-2003: Method of Measurements of Radio-Noise Emissions from Low-Voltage
           Electrical and Electronic Equipment in the 9KHz to 40GHz
          ANSI C63.10-2009: American National Standard for Testing Unlicensed Wireless Devices
          US Code of Federal Regulations (CFR): Title 47, Part 2, Subpart J: Equipment Authorization
           Procedures, 2013
          US Code of Federal Regulations (CFR): Title 47, Part 15, Subpart C: Radio Frequency Devices,
           Intentional Radiators, 2013
          Industry Canada Radio Standards Specification: RSS-210 - Low-power License-exempt
           Radiocommunication Devices (All Frequency Bands): Category I Equipment, Issue 8, Dec 2010
          Industry Canada Radio Standards Specification:        RSS-GEN – General Requirements and
           Information for the Certification of Radiocommunication Equipment, Issue 3, Dec 2010.




ACS Report: 13-0073.W06.1A                   Advanced Compliance Solutions                  Page 7


Model: LFADV                                      FCC ID: N6SLFADV                                  IC: 827B-LFADV

4      LIST OF TEST EQUIPMENT

The calibration interval of test equipment is annually or the manufacturer’s recommendations.
Where the calibration interval deviates from the annual cycle based on the instrument
manufacturer’s recommendations, it shall be stated below.

                                         Table 4-1: Test Equipment
                                                                                                              Calibration
    AssetID    Manufacturer         Model #          Equipment Type        Serial #   Last Calibration Date    Due Date
       1      Rohde & Schwarz    ESMI - Display     Spectrum Analyzers   833771/007         8/2/2012          8/2/2014
       2      Rohde & Schwarz    ESMI-Receiver      Spectrum Analyzers   839587/003         8/2/2012          8/2/2014
      40          EMCO               3104               Antennas            3211           2/14/2013          2/14/2015
      78          EMCO               6502               Antennas         9104-2608          2/5/2013          2/5/2015
      153         EMCO              3825/2                 LISN           9411-2268        7/31/2012          7/31/2014
                                 Chamber EMI
     167            ACS            Cable Set            Cable Set            167           12/17/2012         12/17/2013
      168      Hewlett Packard      11947A             Attenuators          44829            2/1/2013           2/1/2014
     283      Rohde & Schwarz       FSP40           Spectrum Analyzers     1000033          8/1/2012           8/1/2013
     321      Hewlett Packard     HPC 8447D             Amplifiers       1937A02809        8/27/2012           8/27/2013
      324           ACS             Belden                Cables             8214           6/26/2012          6/26/2013
     412       Electro Metrics      LPA-25              Antennas            1241           7/27/2012           7/27/2014
     RE90          Agilent          E7404A              Analyzers        US40240143        11/28/2012         11/28/2013




ACS Report: 13-0073.W06.1A                          Advanced Compliance Solutions                              Page 8


Model: LFADV                            FCC ID: N6SLFADV                             IC: 827B-LFADV

5    SUPPORT EQUIPMENT

                                 Table 5-1: Support Equipment
    Item   Equipment Type        Manufacturer          Model Number                   Serial Number
                                                            MINI-PS-100-
     1     Power Supply          Phoenix Contact                                     3012520353
                                                            240AC/24DC/4
     2     Support Board         Gilbarco                   M09112A001               90210424
                                                                                     CN-0TD761-12961-
     3     Laptop                Dell                       PP18L
                                                                                     68G-3200
                                                                                     CN-0F7970-71615-
     4     Power Supply          Dell                       PA-1650-05D2
                                                                                     55M-6BF4


6    EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM




                                                    EUT


                                        A
                                                    B           C
                    1

                                    2
                        D
                                                            3                4
                                                                      E
               AC Mains                                                          F


    A: +24Vdc Wires, Non-Shielded, 330 cm                                 AC Mains
    B: +5Vdc Wire, Non-Shielded, 300 cm
    C: RS-232 Cable, Non-Shielded, 350 cm               Located Outside Test Environment
    D: AC Power Cable, Non-Shielded, 200 cm
    E: DC Power Cable, Non-Shielded, 100 cm
    F: AC Power Cable, Non-Shielded, 200 cm




ACS Report: 13-0073.W06.1A                  Advanced Compliance Solutions                    Page 9


Model: LFADV                                    FCC ID: N6SLFADV                           IC: 827B-LFADV

7      SUMMARY OF TESTS

Along with the tabular data shown below, plots were taken of all signals deemed important
enough to document.

7.1      Antenna Requirement – FCC: Section 15.203

The antenna is a PCB loop antenna which is integral to the design.

7.2      Power Line Conducted Emissions – FCC: Section 15.207 IC: RSS-Gen 7.2.4

7.2.1      Measurement Procedure

ANSI C63.4 sections 6 and 7 were the guiding documents for this evaluation. Conducted
emissions were performed from 150kHz to 30MHz with the spectrum analyzer’s resolution
bandwidth set to 9kHz and the video bandwidth set to 30kHz. The calculation for the conducted
emissions is as follows:

Corrected Reading = Analyzer Reading + LISN Loss + Cable Loss
Margin = Applicable Limit - Corrected Reading

7.2.2      Measurement Results

Results of the test are shown below in and Table 7.2.2-1.

                                    Table 7.2.2-1: Conducted EMI Results

                Uncorrected Reading     Total        Corrected Level          Limit                 Margin
    Frequency         (dBuV)          Correction         (dBuV)              (dBuV)                  (dB)
      (MHz)                            Factor
                 Quasi-                  (dB)       Quasi-              Quasi-              Quasi-
                          Average                             Average            Average                Average
                  Peak                               Peak                Peak                Peak
                                                             Line 1
    0.166206     36.473    31.205        9.99       46.46       41.20   65.54     55.54      19.1        14.3
     0.20915     32.189    28.064        9.92       42.11       37.98   64.31     54.31      22.2        16.3
    0.500318     31.756    32.033        9.99       41.75       42.02   56.00     46.00      14.3            4.0
     0.50135     32.108    32.073        9.99       42.10       42.06   56.00     46.00      13.9            3.9
     2.42498     25.646    25.904       10.00       35.65       35.91   56.00     46.00      20.4        10.1
     2.50735     27.288    27.206       10.01       37.29       37.21   56.00     46.00      18.7            8.8
                                                             Line 2
    0.167106     36.131    30.067        9.99       46.12       40.06   65.51     55.51      19.4        15.5
    0.501118     31.03     31.328        9.99       41.02       41.32   56.00     46.00      15.0            4.7
     0.5015      31.352    31.291        9.99       41.34       41.28   56.00     46.00      14.7            4.7
     1.92084     26.733    26.875       10.00       36.73       36.87   56.00     46.00      19.3            9.1
     2.00511     27.234    27.193       10.00       37.23       37.19   56.00     46.00      18.8            8.8
     2.21086     28.524     28.11       10.00       38.53       38.11   56.00     46.00      17.5            7.9




ACS Report: 13-0073.W06.1A                         Advanced Compliance Solutions                      Page 10


Model: LFADV                            FCC ID: N6SLFADV                          IC: 827B-LFADV


7.3     Radiated Emissions – FCC CFR 47 Part 15.209 / RSS-210 Section 2.5

7.3.1    Measurement Procedure

Section 15.33(a)(4) specifies, if the intentional radiator contains a digital device, regardless of
whether this digital device controls the functions of the intentional radiator or the digital device is
used for additional control or function purposes other than to enable the operation of the
intentional radiator, the frequency range shall be investigated up to frequency specified in
15.33(b)(1) for unintentional radiators. The upper frequency range for the digital device is
                                        th
1000MHz which greater than the 10 harmonic of the fundamental frequency. The upper
frequency range measured was 1000MHz.

Measurements below 30MHz were performed in a semi-anechoic chamber with a 3 meter
separation distance between the EUT and measurement antenna. The EUT was rotated 360º
and the loop antenna rotated about the vertical axis to maximize each emission. The magnetic
loop receiving antenna was positioned with its center 1 meter above the ground.

The spectrum analyzer’s resolution and video bandwidth was set to 200 Hz and 1 kHz
respectively for frequencies below 150 kHz and 9 kHz and 30 kHz respectively for frequencies
above 150 kHz and below 30 MHz. For measurements in the frequency bands 9-90 kHz and
110-490 kHz, an average detector was used. When average measurements are specified, the
peak emissions were also compared to a limit corresponding to 20 dB above the maximum
permitted average limit according to Part 15.35. All other emissions were measured using a
Quasi-peak detector.

Measurements above 30 MHz were performed in a semi-anechoic chamber with a 3 meter
separation distance between the EUT and measurement antenna. The EUT was rotated through
360° and the receive antenna height was varied from 1m to 4m so that the maximum radiated
emissions level would be detected. For frequencies below 1000 MHz, quasi-peak measurements
were made using a resolution bandwidth (RBW) of 120 kHz and a video bandwidth (VBW) of 300
kHz.

For measurements of fundamental emissions where average measurements are specified, the
spectrum analyzer’s resolution bandwidth (RBW) was adjusted equal to or greater than the
emission bandwidth (EBW).




ACS Report: 13-0073.W06.1A                 Advanced Compliance Solutions                    Page 11


Model: LFADV                                  FCC ID: N6SLFADV                              IC: 827B-LFADV

7.3.2 Distance Correction for Measurements Below 30 MHz – Part 15.31
Radiated measurements were performed at a distance closer than 300 meters and 30m as
required, according to Part 15.209. Therefore a correction factor was applied to account for
propagation loss at the specified distance. The propagation loss was determined by using the
square of an inverse linear distance extrapolation factor (40dB/decade) according to 15.31. A
sample calculation of the distance correction factor is shown below for limits expressed at a 300m
measurement distance and a 30m measurement distance.

Distance correction factor (300m Specified Test Distance) = 40*Log (Test Distance/300)
                           = 40*Log (3/300)
                           = - 80 dB

Distance correction factor (30m Specified Test Distance) = 40*Log (Test Distance/30)
                           = 40*Log (3/30)
                           = - 40 dB

7.3.3   Measurement Results

Results of the test are given in Tables 7.3.3-1 to 7.3.3-2.

                                 Table 7.3.3-1: Fundamental Field Strength
                         Level         Antenna    Correction   Corrected Level         Limit                  Margin
  Frequency             (dBuV)         Polarity     Factors       (dBuV/m)           (dBuV/m)                  (dB)
    (MHz)
                pk         Qpk/Avg      (H/V)        (dB)       pk      Qpk/Avg    pk      Qpk/Avg    pk        Qpk/Avg
    0.1342     87.56        87.22         H          10.77     98.33     97.99    125.0     105.0    26.7         7.1
                                       Note: RBW set to 9kHz (RBW>>EBW).

                                     Table 7.3.3-2: Radiated Emissions
                         Level         Antenna    Correction   Corrected Level         Limit                  Margin
  Frequency             (dBuV)         Polarity     Factors       (dBuV/m)           (dBuV/m)                  (dB)
    (MHz)
                 pk        Qpk/Avg      (H/V)        (dB)        pk     Qpk/Avg     pk     Qpk/Avg     pk       Qpk/Avg
    0.4026     52.18        52.18         H         10.61      62.79     62.79    115.5     95.5     52.7        32.7
     0.671      -----       43.93         H         10.80       -----    54.73     -----    71.1      -----      16.3
    0.9394      -----       39.54         H          10.78      -----    50.32     -----    68.1      -----      17.8
    1.2078      -----       36.42         H         10.92       -----    47.34     -----    66.0      -----      18.6
    1.4762      -----       30.56         H          10.95      -----    41.51     -----    64.2      -----       22.7
     1.744      -----       28.32         H          10.97      -----    39.29     -----    69.5      -----      30.2
     2.016      -----       26.68         H          11.01      -----    37.69     -----    69.5      -----      31.80
     2.288      -----       23.59         H          11.17      -----    34.76     -----    69.5      -----      34.70
     2.552      -----       23.69         H          11.33      -----    35.02     -----    69.5      -----      34.50
     2.824      -----       21.96         H          11.49      -----    33.45     -----    69.5      -----      36.00
     26.04      -----       32.15                    10.27      -----    42.42     -----    69.5      -----      27.10
     29.82      -----       37.41         H          9.44       -----    46.85     -----    69.5      -----      22.70
       30       -----       50.12         V         -12.90      -----    37.22     -----    40.0      -----      2.80
      38.5      -----       49.69         V         -14.38      -----    35.31     -----    40.0      -----      4.70
     76.09      -----       55.20         H         -18.24      -----    36.96     -----    40.0      -----      3.00
     91.22      -----       49.25         H         -13.77      -----    35.48     -----    43.5      -----      8.00
    148.06      -----       37.22         V         -12.05      -----    25.17     -----    43.5      -----      18.30




ACS Report: 13-0073.W06.1A                        Advanced Compliance Solutions                         Page 12


Model: LFADV                         FCC ID: N6SLFADV                       IC: 827B-LFADV

7.3.4 Sample Calculation
Example Calculation – Average/Quasi-Peak Limit < 30MHz

Measurement Distance 300m @ 134 kHz

Limit (dBuV/m) = 20*Log(2400/F(kHz)) - Distance Correction Factor (Section 7.3.2)
Limit (dBuV/m) = 20*Log(2400/134) + 80
Limit (dBuV/m) = 105.06

Example Calculation - 134 kHz (See Table 7.3.3-1)
RC = RU + CFT
Where:
CFT    =      Total Correction Factor (AF+CA+AG)
RU     =      Uncorrected Reading
RC     =      Corrected Level
AF     =      Antenna Factor
CA     =      Cable Attenuation
AG     =      Amplifier Gain

Peak:
Corrected Level: 87.56 + 10.77 = 98.33dBuV
Margin: 125.06dBuV – 98.33dBuV = 26.7 dB

Average:
Corrected Level: 87.22 + 10.77 = 97.99dBuV
Margin: 105.06dBuV – 97.99dBuV = 7.1 dB




ACS Report: 13-0073.W06.1A              Advanced Compliance Solutions               Page 13


Model: LFADV                                  FCC ID: N6SLFADV                                  IC: 827B-LFADV

7.4     20dB / 99% Bandwidth – FCC: Section 15.215, IC: RSS-Gen 4.6.1

7.4.1    Measurement Procedure

The span of the spectrum analyzer display was set between two times and five times the
occupied bandwidth (OBW) of the emission. The RBW of the spectrum analyzer was set to
100Hz. The trace was set to max hold with a peak detector active. The Delta function of the
analyzer was utilized to determine the 20 dB bandwidth of the emission.

The occupied bandwidth measurement function of the analyzer was used for the 99% bandwidth.
The span of the analyzer shall be set to capture all products of the modulation process, including
the emission skirts. The resolution bandwidth shall be set to as close to 1% of the selected span
as is possible without being below 1%. A sampling detector was used.

7.4.2    Measurement Results

Results are shown below in table 7.4.2-1 and figure 7.4.2-1 to 7.4.2-2:

                                Table 7.4.2-1: 20dB / 99% Bandwidth
                       Frequency           20dB Bandwidth        99% Bandwidth
                          [kHz]                 [kHz]                [kHz]
                           134                   1.74                 4.44

                                                          * RBW 100 Hz   Marker 1 [T1 ]
                                                                                   -82.45 dBm
                Ref -50 dBm             Att   10 dB        AQT 40 ms        134.988000000 kHz
                -50                                                      Delta 1 [T1 ]
                                                                                    -0.04 dB
                                                                             -1.740000000 kHz    A
                -60

         1 PK
         VIEW
                -70



                -80                           1                 1



                -90



                -100

                                                                                                FFT
                -110



                -120



                -130



                -140


                -150

                Center 134.2 kHz                      800 Hz/                      Span 8 kHz




         Date: 29.APR.2013         14:33:40

                                    Figure 7.4.2-1: 20dB Bandwidth Plot




ACS Report: 13-0073.W06.1A                        Advanced Compliance Solutions                        Page 14


Model: LFADV                                FCC ID: N6SLFADV                                   IC: 827B-LFADV

                                                         * RBW 100 Hz   Marker 1 [T1 ]
                                                                                  87.87 dBµV
             Ref   97 dBµV           Att   10 dB          AQT 40 ms        134.220000000 kHz

                                                                        OBW 4.440000000 kHz
             90                                      1                  Temp 1 [T1 OBW]
                                                                                  59.31 dBµV    A

                                                                           132.320000000 kHz
       1 SA *
              80                                                        Temp 2 [T1 OBW]
       VIEW
                                                                                  58.61 dBµV
                                                                           136.760000000 kHz
             70


                                    T1                                    T2
             60



             50



             40                                                                                FFT



             30



             20



             10



             0

             Center 134.2 kHz                      1 kHz/                        Span 10 kHz




       Date: 18.MAR.2013        14:59:37

                                  Figure 7.4.2-2: 99% Bandwidth Plot



8   CONCLUSION

In the opinion of ACS, Inc., the LFADV, manufactured by Gilbarco Inc. meet the requirements of
FCC Part 15 subpart C and Industry Canada’s Radio Standards Specification RSS-210.




                                           END REPORT




ACS Report: 13-0073.W06.1A                     Advanced Compliance Solutions                          Page 15



Document Created: 2013-05-03 10:21:29
Document Modified: 2013-05-03 10:21:29

© 2024 FCC.report